1
|
Pham DQ, Gangadoo S, Berndt CC, Chapman J, Zhai J, Vasilev K, Truong VK, Ang ASM. Antibacterial Longevity of a Novel Gallium Liquid Metal/Hydroxyapatite Composite Coating Fabricated by Plasma Spray. ACS APPLIED MATERIALS & INTERFACES 2022; 14:18974-18988. [PMID: 35416647 DOI: 10.1021/acsami.2c03695] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hydroxyapatite (HAp)-coated metallic implants are known for their excellent bioactivity and osteoconductivity. However, infections associated with the microstructure of the HAp coatings may lead to implant failures as well as increased morbidity and mortality. This work addresses the concerns about infections by developing novel composite coatings of HAp and gallium liquid metal (GaLM) using atmospheric plasma spray (APS) as the coating technique. Five weight percent Ga was mixed into a commercially supplied HAp powder using an orbital shaker; then, the HAp-Ga particle feedstock was coated onto Ti6Al4V substrates using the APS technique. The X-ray diffraction results indicated that Ga did not form any Ga-related phases in either the HAp-Ga powder or the respective coating. The GaLM filled the pores of the HAp coating presented both on the top surface and within the coating, especially at voids and cracks, to prevent failures of the coating at these locations. The wettability of the surface was changed from hydrophobic for the HAp coating to hydrophilic for the HAp-Ga composite coating. Finally, the HAp-Ga coating presented excellent antibacterial efficacies against both initial attachments and established biofilms generated from methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa after 18 h and 7 days of incubation in comparison to the control HAp coating. This study shows that GaLM improves the antibacterial properties of HAp-based coatings without sacrificing the beneficial properties of conventional HAp coatings. Thus, the HAp-Ga APS coating is a viable candidate for antibacterial coatings.
Collapse
Affiliation(s)
- Duy Quang Pham
- ARC Training Centre for Surface Engineering for Advanced Materials (SEAM), Department of Mechanical Engineering & Product Design Engineering, School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - Sheeana Gangadoo
- School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
| | - Christopher C Berndt
- ARC Training Centre for Surface Engineering for Advanced Materials (SEAM), Department of Mechanical Engineering & Product Design Engineering, School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - James Chapman
- School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
| | - Jiali Zhai
- School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
| | - Krasimir Vasilev
- College of Medicine and Public Health, Flinders University, Bedford Park, SA 5042, Australia
| | - Vi Khanh Truong
- College of Medicine and Public Health, Flinders University, Bedford Park, SA 5042, Australia
| | - Andrew S M Ang
- ARC Training Centre for Surface Engineering for Advanced Materials (SEAM), Department of Mechanical Engineering & Product Design Engineering, School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| |
Collapse
|
2
|
Effect of titanium dioxide intermediate layer on scratch and corrosion resistance of sol-gel-derived HA coating applied on Ti-6Al-4V substrate. Prog Biomater 2021; 10:259-269. [PMID: 34741278 DOI: 10.1007/s40204-021-00169-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Accepted: 10/15/2021] [Indexed: 10/19/2022] Open
Abstract
Modification of dental and orthopedic implants' surface by coating them with bioactive materials, such as hydroxyapatite (HA), diminishes the implants' fixation time. Appropriate adhesion to the substrate and stability in biological conditions are essential requirements for these coatings. In this study, sol-gel-derived HA coating was applied on the Ti-6Al-4 V substrate, which is a high-performance alloy for manufacturing bone implants. Also, titanium dioxide (TiO2) which was prepared by the sol-gel method was used as an intermediate layer between HA coating and the substrate. The nano-scratch and potentiodynamic polarization tests were employed to evaluate the effectiveness of TiO2 intermediate layer on improving the scratch resistance, as an indicator of coating adhesion strength, and the corrosion resistance of the coated samples. The quality of the coating bonded to the substrate was studied by cross-sectional SEM images. The XRD tests indicated that HA and TiO2 coatings were formed with predetermined phase compositions. The biocompatibility of sol-gel-derived HA coating was established by simulated body fluid (SBF) immersion tests. The SEM images, along with the results of electrochemical and nano-scratch tests, proved the significant effect of a TiO2 intermediate layer on improving the scratch resistance and stability of HA coating on titanium alloy substrate.
Collapse
|
3
|
Current Challenges and Innovative Developments in Hydroxyapatite-Based Coatings on Metallic Materials for Bone Implantation: A Review. COATINGS 2020. [DOI: 10.3390/coatings10121249] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Biomaterials are in use for the replacement and reconstruction of several tissues and organs as treatment and enhancement. Metallic, organic, and composites are some of the common materials currently in practice. Metallic materials contribute a big share of their mechanical strength and resistance to corrosion properties, while organic polymeric materials stand high due to their biocompatibility, biodegradability, and natural availability. To enhance the biocompatibility of these metals and alloys, coatings are frequently applied. Organic polymeric materials and ceramics are extensively utilized for this purpose due to their outstanding characteristics of biocompatibility and biodegradability. Hydroxyapatite (HAp) is the material from the ceramic class which is an ultimate candidate for coating on these metals for biomedical applications. HAp possesses similar chemical and structural characteristics to normal human bone. Due to the bioactivity and biocompatibility of HAp, it is used for bone implants for regenerating bone tissues. This review covers an extensive study of the development of HAp coatings specifically for the orthopaedic applications that include different coating techniques and the process parameters of these coating techniques. Additionally, the future direction and challenges have been also discussed briefly in this review, including the coating of HAp in combination with other calcium magnesium phosphates that occur naturally in human bone.
Collapse
|
4
|
Pantawane MV, Ho YH, Robertson WB, Khan RJK, Fick DP, Dahotre NB. Thermal Assessment of Ex Vivo Laser Ablation of Cortical Bone. ACS Biomater Sci Eng 2020; 6:2415-2426. [PMID: 33455309 DOI: 10.1021/acsbiomaterials.9b01559] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
As a potential osteotomy tool, laser ablation is expected to provide rapid machining of bone, while generating minimal thermal damage (carbonization) and physical attributes within the machined region conducive to healing. As these characteristics vary with laser parameters and modes of laser operation, the clinical trials and in vivo studies render it difficult to explore these aspects for optimization of the laser machining parameters. In light of this, the current work explores various thermal and microstructural aspects of laser-ablated cortical bone in ex vivo study to understand the fundamentals of laser-bone interaction using computational modeling. The study employs the Yb-fiber Nd:YAG laser (λ = 1064 nm) in the continuous wave mode to machine the femur section of bovine bone by a three-dimensional machining approach. The examination involved thermal analysis using differential scanning calorimetry and thermogravimetry, phase analysis using X-ray diffractometry, qualitative analysis using X-ray photoelectron spectroscopy, and microstructural and semiquantitative analysis using scanning electron microscopy equipped with energy-dispersive spectrometry. The mechanism of efficient bone ablation using the Nd:YAG laser was evaluated using the computational thermokinetics outcome. The use of high laser fluence (10.61 J/mm2) was observed to be efficient to reduce the residual amorphous carbon in the heat-affected zone while achieving removal of the desired volume of the bone material at a rapid rate. Minimal thermal effects were predicted through computational simulation and were validated with the experimental outcome. In addition, this work reveals the in situ formation of a scaffold-like structure in the laser-machined region which can be conducive during healing.
Collapse
Affiliation(s)
- Mangesh V Pantawane
- Laboratory for Laser Aided Additive and Subtractive Manufacturing, Virtual Center for Advanced Orthopedics, Department of Materials Science and Engineering, University of North Texas, 1155 Union Circle-305310, Denton, Texas 76203-5017, United States
| | - Yee-Hsien Ho
- Laboratory for Laser Aided Additive and Subtractive Manufacturing, Virtual Center for Advanced Orthopedics, Department of Materials Science and Engineering, University of North Texas, 1155 Union Circle-305310, Denton, Texas 76203-5017, United States
| | - William B Robertson
- Laboratory for Laser Aided Additive and Subtractive Manufacturing, Virtual Center for Advanced Orthopedics, Department of Materials Science and Engineering, University of North Texas, 1155 Union Circle-305310, Denton, Texas 76203-5017, United States.,Australian Institute of Robotics Orthopedics, 2 Centro Avenue, Subiaco, Western Australia 6008, Australia.,Department of Computing School of Electrical Engineering and Computing, Curtin University, Kent Street, Bentley, Western Australia 6102, Australia
| | - Riaz J K Khan
- Laboratory for Laser Aided Additive and Subtractive Manufacturing, Virtual Center for Advanced Orthopedics, Department of Materials Science and Engineering, University of North Texas, 1155 Union Circle-305310, Denton, Texas 76203-5017, United States.,Australian Institute of Robotics Orthopedics, 2 Centro Avenue, Subiaco, Western Australia 6008, Australia.,Department of Computing School of Electrical Engineering and Computing, Curtin University, Kent Street, Bentley, Western Australia 6102, Australia.,The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, Western Australia 6009, Australia
| | - Daniel P Fick
- Laboratory for Laser Aided Additive and Subtractive Manufacturing, Virtual Center for Advanced Orthopedics, Department of Materials Science and Engineering, University of North Texas, 1155 Union Circle-305310, Denton, Texas 76203-5017, United States.,Australian Institute of Robotics Orthopedics, 2 Centro Avenue, Subiaco, Western Australia 6008, Australia.,Department of Computing School of Electrical Engineering and Computing, Curtin University, Kent Street, Bentley, Western Australia 6102, Australia.,The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, Western Australia 6009, Australia
| | - Narendra B Dahotre
- Laboratory for Laser Aided Additive and Subtractive Manufacturing, Virtual Center for Advanced Orthopedics, Department of Materials Science and Engineering, University of North Texas, 1155 Union Circle-305310, Denton, Texas 76203-5017, United States
| |
Collapse
|
5
|
Mechanical Properties of Strontium–Hardystonite–Gahnite Coating Formed by Atmospheric Plasma Spray. COATINGS 2019. [DOI: 10.3390/coatings9110759] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this work, we measured the mechanical properties and tested the cell viability of a bioceramic coating, strontium–hardystonite–gahnite (Sr–HT–G, Sr–Ca2ZnSi2O7–ZnAl2O4), to evaluate potential use of this novel bioceramic for bone regeneration applications. The evaluation of Sr–HT–G coatings deposited via atmospheric plasma spray (APS) onto Ti–6Al–4V substrates have been contrasted to the properties of the well-known commercial standard coating of hydroxyapatite (HAp: Ca10(PO4)6(OH)2). The Sr–HT–G coating exhibited uniform distribution of hardness and elastic moduli across its cross-section; whereas the HAp coating presented large statistical variations of these distributions. The Sr–HT–G coating also revealed higher results of microhardness, nanohardness and elastic moduli than those shown for the HAp coating. The nanoscratch tests for the Sr–HT–G coating presented a low volume of material removal without high plastic deformation, while the HAp coating revealed ploughing behaviour with a large pileup of materials and plastic deformation along the scratch direction. Furthermore, nanoscanning wear tests indicated that Sr–HT–G had a lower wear volume than the HAp coating. The Sr–HT–G coating had slightly higher cell attachment density and spreading area compared to the HAp coating indicating that both coatings have good biocompatibility for bone marrow mesenchymal stem cells (BMSCs).
Collapse
|
6
|
Wang Y, Liu X, Fan T, Tan Z, Zhou Z, He D. In vitro evaluation of hydroxyapatite coatings with (002) crystallographic texture deposited by micro-plasma spraying. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 75:596-601. [PMID: 28415504 DOI: 10.1016/j.msec.2017.02.119] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 02/21/2017] [Accepted: 02/22/2017] [Indexed: 01/08/2023]
Abstract
Hydroxyapatite (HA) coatings are usually deposited on the metallic implant to increase the biocompatibility and protect the bloodstream from harmful metal ions. Atmospheric plasma spray (APS) is known as a cost effective deposition method. However, the low crystallinity of APS deposited coating accelerates its dissolution in body fluid. We used micro-plasma spray (MPS) to develop chemically stable HA coatings, and performed APS as reference. Results showed that MPS deposited coatings exhibited (002) crystallographic texture while the reference sample did not. The texture intensity and crystallinity were improved by shortening stand-off distance. These suggested that different formation procedures of HA coatings were involved and three mechanisms were proposed by sketching typical splats. To evaluate the chemical stability of the coatings in a physiological environment, in vitro experiments were performed in Hanks' solution. Well crystallized (~100%) HA coating with the strongest crystallographic texture exhibited superior stability up to 14days. Crystals with (002) orientation was more stable than that with (211) orientation. Hence columnar structure with nanopores emerged on the coating surface after incubation, and this may facilitate the future osteoblast growth. Furthermore, HA coating with weak and no crystallographic texture induced apatite layer. However, vertical cracks and cleavage at coating-apatite interface may cause coating separation.
Collapse
Affiliation(s)
- Yiming Wang
- College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, China.
| | - Xiaomei Liu
- College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, China
| | - Tingting Fan
- College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, China
| | - Zhen Tan
- College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, China
| | - Zheng Zhou
- College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, China
| | - Dingyong He
- College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, China; Beijing Engineering Research Center of Eco-materials and LCA, Beijing 100124, China
| |
Collapse
|
7
|
Demnati I, Grossin D, Marsan O, Bertrand G, Collonges G, Combes C, Parco M, Braceras I, Alexis J, Balcaen Y, Rey C. Comparison of Physical-chemical and Mechanical Properties of Chlorapatite and Hydroxyapatite Plasma Sprayed Coatings. Open Biomed Eng J 2015; 9:42-55. [PMID: 25893015 PMCID: PMC4391221 DOI: 10.2174/1874120701509010042] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2014] [Revised: 08/02/2014] [Accepted: 08/20/2014] [Indexed: 11/22/2022] Open
Abstract
Chlorapatite can be considered a potential biomaterial for orthopaedic applications. Its use as plasma-sprayed coating could be of interest considering its thermal properties and particularly its ability to melt without decomposition unlike hydroxyapatite. Chlorapatite (ClA) was synthesized by a high-temperature ion exchange reaction starting from commercial stoichiometric hydroxyapatites (HA). The ClA powder showed similar characteristics as the original industrial HA powder, and was obtained in the monoclinic form. The HA and ClA powders were plasma-sprayed using a low-energy plasma spraying system with identical processing parameters. The coatings were characterized by physical-chemical methods, i.e. X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and Raman spectroscopy, including distribution mapping of the main phases detected such as amorphous calcium phosphate (ACP), oxyapatite (OA), and HA or ClA. The unexpected formation of oxyapatite in ClA coatings was assigned to a side reaction with contaminating oxygenated species (O2, H2O). ClA coatings exhibited characteristics different from HA, showing a lower content of oxyapatite and amorphous phase. Although their adhesion strength was found to be lower than that of HA coatings, their application could be an interesting alternative, offering, in particular, a larger range of spraying conditions without formation of massive impurities.
Collapse
Affiliation(s)
- Imane Demnati
- Université de Toulouse, CIRIMAT, INPT-CNRS-UPS, ENSIACET, Toulouse, France
| | - David Grossin
- Université de Toulouse, CIRIMAT, INPT-CNRS-UPS, ENSIACET, Toulouse, France
| | - Olivier Marsan
- Université de Toulouse, CIRIMAT, INPT-CNRS-UPS, ENSIACET, Toulouse, France
| | - Ghislaine Bertrand
- Université de Toulouse, CIRIMAT, INPT-CNRS-UPS, ENSIACET, Toulouse, France
| | | | - Christèle Combes
- Université de Toulouse, CIRIMAT, INPT-CNRS-UPS, ENSIACET, Toulouse, France
| | - Maria Parco
- Tecnalia, Mikeletegi Pasealekua 2, Donostia-San Sebastian, Spain
| | - Inigo Braceras
- Tecnalia, Mikeletegi Pasealekua 2, Donostia-San Sebastian, Spain
| | - Joel Alexis
- Université de Toulouse, INPT-ENIT, Laboratoire Génie de Production, Tarbes, France
| | - Yannick Balcaen
- Université de Toulouse, INPT-ENIT, Laboratoire Génie de Production, Tarbes, France
| | - Christian Rey
- Université de Toulouse, CIRIMAT, INPT-CNRS-UPS, ENSIACET, Toulouse, France
| |
Collapse
|