1
|
Chikhale R, Akhare P, Umre U, Jawlekar R, Kalokhe S, Badole N, Beri A. In Vitro Comparison to Evaluate Metal Ion Release: Nickel-Titanium vs. Titanium-Molybdenum Orthodontic Archwires. Cureus 2024; 16:e56595. [PMID: 38646368 PMCID: PMC11032127 DOI: 10.7759/cureus.56595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 03/20/2024] [Indexed: 04/23/2024] Open
Abstract
Background When metals used in orthodontic materials are exposed to the oral environment, teeth, and gingivae over an extended period of time, they may gradually deteriorate. As a result, the patient is exposed to higher concentrations of metals and metal ions than what they would be exposed to through food and other sources. The goal of the current in vitro experiment was to evaluate and contrast the metal ion release from orthodontic archwires made of titanium-molybdenum alloy (TMA) and nickel-titanium (NiTi). Methods For 90 days, 20 orthodontic archwires in each group were immersed in 50 milliliters of simulated saliva using different containers. Atomic Absorption Spectrometry (AAS) (Shimadzu Corporation, Kyoto, Japan) was used to assess and compare metal ion emission. The unit of measurement is parts per million (PPM). Results The findings indicated that the discharge of nickel metal from the NiTi archwire (Group A) was much higher than that from the TMA archwire (Group B), with a statistical significance level of p < 0.001. It was discovered that Group B's release of titanium was statistically significantly (p < 0.05) higher than Group A's titanium release, which did not include the release of any other metals. Conclusion The study findings indicated that the amounts of metal ions released from the orthodontic archwires made of titanium molybdenum and nickel-titanium alloy were within safety limits.
Collapse
Affiliation(s)
- Rana Chikhale
- Orthodontics and Dentofacial Orthopaedics, Swargiya Dadasaheb Kalmegh Smruti Dental College, Nagpur, IND
| | - Pankaj Akhare
- Orthodontics and Dentofacial Orthopaedics, Swargiya Dadasaheb Kalmegh Smruti Dental College, Nagpur, IND
| | - Utkarsh Umre
- Endodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Rashmi Jawlekar
- Orthodontics and Dentofacial Orthopaedics, Swargiya Dadasaheb Kalmegh Smruti Dental College, Nagpur, IND
| | - Shantanu Kalokhe
- Orthodontics and Dentofacial Orthopaedics, Swargiya Dadasaheb Kalmegh Smruti Dental College, Nagpur, IND
| | - Neha Badole
- Orthodontics and Dentofacial Orthopaedics, Swargiya Dadasaheb Kalmegh Smruti Dental College, Nagpur, IND
| | - Arushi Beri
- Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
2
|
Mirhashemi SA, Jahangiri S, Mahdavi Moghaddam M, Bahrami R. Nickel and Chromium Ion Release from Orthodontic Wires Subjected to Various Drinks and Distilled Water. Front Dent 2023; 20:33. [PMID: 37876792 PMCID: PMC10591019 DOI: 10.18502/fid.v20i33.13639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 02/28/2023] [Indexed: 10/26/2023] Open
Abstract
Objectives: The aim of this in vitro study was to assess the quantity of nickel and chromium ions released from orthodontic wires when subjected to various beverage solutions and distilled water. Materials and Methods: Orthodontic appliances composed of five brackets, one band and 0.016-inch stainless steel and nickel titanium wires were immersed in Coke, tea, coffee and distilled water. The samples were incubated at 37°C for 1 hour, 6 hours, 24 hours, and one week. There was a total of 120 appliances divided into 24 groups (n=5 in each group). Atomic absorption spectroscopy was used to examine the amount of released ions. Two-way and one-way ANOVA followed by Tukey test were used for statistical analysis and P<0.05 was considered significant. Results: The release of nickel ions from both wires was highest in Coke and lowest in distilled water at all time points. Coffee and tea demonstrated values in-between these two limits. Similarly, chromium ion release from both wires was highest in Coke at all time-points compared to all other solutions (P<0.05). None of the other tested drinks showed significant differences in chromium ion release compared to distilled water. Conclusion: Restricting the intake of acidic drinks, particularly carbonated beverages like Coke, plays a critical role in safeguarding orthodontic wire components. Educating patients and providing dietary guidelines are essential for maximizing treatment effectiveness. Further research is required to investigate additional factors impacting ion release and devising methods to mitigate potential harm.
Collapse
Affiliation(s)
- Seyyed Amirhossein Mirhashemi
- Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
- Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | - Rashin Bahrami
- Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
- Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
3
|
Durgo K, Orešić S, Rinčić Mlinarić M, Fiket Ž, Jurešić GČ. Toxicity of Metal Ions Released from a Fixed Orthodontic Appliance to Gastrointestinal Tract Cell Lines. Int J Mol Sci 2023; 24:9940. [PMID: 37373088 DOI: 10.3390/ijms24129940] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 06/06/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023] Open
Abstract
The mechanism of toxicity and cellular response to metal ions present in the environment is still a very current area of research. In this work, which is a continuation of the study of the toxicity of metal ions released by fixed orthodontic appliances, eluates of archwires, brackets, ligatures, and bands are used to test the prooxidant effect, cytotoxicity, and genotoxicity on cell lines of the gastrointestinal tract. Eluates obtained after three immersion periods (3, 7, and 14 days) and with known amounts and types of metal ions were used. Four cell lines-CAL 27 (human tongue), Hep-G2 (liver), AGS (stomach) and CaCo-2 (colon)-were treated with each type of eluate at four concentrations (0.1×, 0.5×, 1.0×, and 2.0×) for 24 h. Most eluates had toxic effects on CAL 27 cells over the entire concentration range regardless of exposure time, while CaCo-2 proved to be the most resistant. In AGS and Hep-G2 cells, all samples tested induced free radical formation, with the highest concentration (2×) causing a decrease in free radicals formed compared to the lowest concentrations. Eluates containing Cr, Mn, and Al showed a slight pro-oxidant effect on DNA (on plasmid φX-174 RF I) and slight genotoxicity (comet assay), but these effects are not so great that the human body could not "resist" them. Statistical analysis of data on chemical composition, cytotoxicity, ROS, genotoxicity, and prooxidative DNA damage shows the influence of metal ions present in some eluates on the toxicity obtained. Fe and Ni are responsible for the production of ROS, while Mn and Cr have a great influence on hydroxyl radicals, which cause single-strand breaks in supercoiled plasmid DNA in addition to the production of ROS. On the other hand, Fe, Cr, Mn, and Al are responsible for the cytotoxic effect of the studied eluates. The obtained results confirm that this type of research is useful and brings us closer to more accurate in vivo conditions.
Collapse
Affiliation(s)
- Ksenija Durgo
- Department of Biochemical Engineering, Faculty of Food Technology and Biotechnology, Universtiy of Zagreb, Pierrotijeva 6, 10000 Zagreb, Croatia
| | - Sunčana Orešić
- Department of Biochemical Engineering, Faculty of Food Technology and Biotechnology, Universtiy of Zagreb, Pierrotijeva 6, 10000 Zagreb, Croatia
| | | | - Željka Fiket
- Division for Marine and Environmental Research, Ruđer Bošković Institute, Bijenička 54, 10000 Zagreb, Croatia
| | - Gordana Čanadi Jurešić
- Department of Medical Chemistry, Biochemistry and Clinical Chemistry, Faculty of Medicine, Universtiy of Rijeka, B. Branchetta 20, 51000 Rijeka, Croatia
| |
Collapse
|
4
|
Petković Didović M, Jelovica Badovinac I, Fiket Ž, Žigon J, Rinčić Mlinarić M, Čanadi Jurešić G. Cytotoxicity of Metal Ions Released from NiTi and Stainless Steel Orthodontic Appliances, Part 1: Surface Morphology and Ion Release Variations. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16114156. [PMID: 37297290 DOI: 10.3390/ma16114156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 05/25/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023]
Abstract
Despite numerous studies on ion release from orthodontic appliances, no clear conclusions can be drawn due to complex interrelations of multiple factors. Therefore, as the first part of a comprehensive investigation of cytotoxicity of eluted ions, the objective of this study was to analyze four parts of a fixed orthodontic appliance. Specifically, NiTi archwires and stainless steel (SS) brackets, bands, and ligatures were immersed in artificial saliva and studied for morphological and chemical changes after 3-, 7-, and 14-day immersion, using the SEM/EDX technique. Ion release profiles were analyzed for all eluted ions using inductively coupled plasma mass spectrometry (ICP-MS). The results demonstrated dissimilar surface morphologies among parts of the fixed appliance, due to variations in manufacturing processes. The onset of pitting corrosion was observed for the SS brackets and bands in the as-received state. Protective oxide layers were not observed on any of the parts, but adherent layers developed on SS brackets and ligatures during immersion. Salt precipitation, mainly KCl, was also observed. ICP-MS proved to be more sensitive than SEM/EDX and exhibited results undetected by SEM/EDX. Ion release was an order-of-magnitude higher for SS bands compared to other parts, which was attributed to manufacturing procedure (welding). Ion release did not correlate with surface roughness.
Collapse
Affiliation(s)
- Mirna Petković Didović
- Department of Medical Chemistry, Biochemistry and Clinical Chemistry, Faculty of Medicine, University of Rijeka, B. Branchetta 20, 51000 Rijeka, Croatia
| | - Ivana Jelovica Badovinac
- Faculty of Physics and Centre for Micro- and Nanosciences and Technologies, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka, Croatia
| | - Željka Fiket
- Division for Marine and Environmental Research, Ruđer Bošković Institute, Bijenička 54, 10000 Zagreb, Croatia
| | - Jure Žigon
- Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, 1000 Ljubljana, Slovenia
| | | | - Gordana Čanadi Jurešić
- Department of Medical Chemistry, Biochemistry and Clinical Chemistry, Faculty of Medicine, University of Rijeka, B. Branchetta 20, 51000 Rijeka, Croatia
| |
Collapse
|
5
|
Metal Release and Surface Degradation of Fixed Orthodontic Appliances during the Dental Levelling and Aligning Phase: A 12-Week Study. COATINGS 2022. [DOI: 10.3390/coatings12050554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The purpose of the present study is twofold: (i) to assess the salivary nickel, chromium, and iron concentrations and (ii) to characterize the surface microstructure of the typical commercially available Ni-containing metallic appliances during the first 12-week orthodontic treatment period. A total of 85 unstimulated saliva samples were collected from patients before treatment, after 2 days, and after 1, 4, and 12 weeks. Salivary ion concentrations were determined by inductively coupled plasma optical emission spectroscopy, and data were analyzed with the Statistical Package for Social Sciences (IBM SPSS) software. The recorded mean metal concentrations were in the ranges of 132–175 µg/L for Ni, 171–192 µg/L for Cr, and 826–1023 µg/L for Fe. No statistically significant variations were observed between the different study times, and the null hypothesis (the concentrations of metallic ions in patients’ saliva did not significantly change after the placement of the orthodontic appliances) was accepted (p > 0.05). Mean salivary metallic ions were below toxic levels, and no adverse clinical reactions were registered. The intraoral surface degradation of the fixed components was corroborated by optical microscopy, scanning electron microscopy, and energy dispersive spectrometry. Microstructural analysis after complete orthodontic procedure confirmed different corrosion types, from pitting to biocorrosion.
Collapse
|
6
|
The effect of nickel ions on the susceptibility of bacteria to ciprofloxacin and ampicillin. Folia Microbiol (Praha) 2022; 67:649-657. [PMID: 35353362 DOI: 10.1007/s12223-022-00960-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 02/19/2022] [Indexed: 11/04/2022]
Abstract
To explore the interaction effects of ciprofloxacin and ampicillin with nickel on the growth of bacteria, Staphylococcus aureus strain ATCC 29213, Enterococcus faecalis ATCC 29212 and Escherichia coli ATCC 25922 were used. Minimum inhibitory concentrations (MICs) were determined for nickel, ciprofloxacin and ampicillin, and the checkerboard method was used to assess their cumulative effects on bacterial growth. The interactions between the metal and antibiotics were assessed by the fractional inhibitory concentration (FIC). The MICs for ciprofloxacin and ampicillin were 0.31 and 1 mg/L for E. faecalis, 0.62 and 1 mg/L for S. aureus and 0.005 and 2.5 for E. coli, respectively. The MIC for nickel was 1000 mg/L for all bacteria. The FIC results for ciprofloxacin and nickel demonstrated an antagonistic effect of the two agents on the growth of E. coli and E. faecalis and an additive effect on S. aureus. The FICs for ampicillin and nickel demonstrated a synergistic effect on the growth of E. faecalis and E. coli. Different interactions of metals and antibiotics were observed depending on the bacteria and the type of antibiotic.
Collapse
|
7
|
Dinu S, Craciunescu EL, Macasoi I, Chioran D, Rivis M, Vlad D, Milutinovici RA, Marcovici I, Dolghi A, Moaca A, Dinu DC, Dehelean C, Popa M. Toxicological Assessment of an Acrylic Removable Orthodontic Appliance Using 2D and 3D In Vitro Methods. MATERIALS 2022; 15:ma15031193. [PMID: 35161136 PMCID: PMC8838812 DOI: 10.3390/ma15031193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 01/20/2022] [Accepted: 02/03/2022] [Indexed: 11/29/2022]
Abstract
Malocclusion is a global health problem, mainly affecting children and adolescents. For this reason, orthodontic treatment must be, on the one hand, safe, non-toxic, and effective and, on the other hand, it must have the best possible esthetic profile. Thus, the use of orthodontic appliances is addressed to all age groups, including young children, for a long period of time, which is why their safety profile is a matter of real interest. For this reason, the purpose of the present study was to evaluate the safety and biocompatibility of an acrylic removable orthodontic appliance made of polymethylmethacrylate and stainless steel alloy made by our team of researchers. To verify the biocompatibility of the medical device, it was immersed in artificial saliva with three different pHs (3, 7, and 10) for a period of ten days. Subsequently, the three types of saliva were tested on human keratinocytes (HaCaT cell line) in terms of viability and modification of cell morphology. Finally, the use of 3D reconstructed human epidermis verified the cytotoxic and irritating potential of the medical device, thus providing relevant information regarding its biocompatibility. The results revealed that by maintaining the orthodontic device in the saliva there is no release of substances with a toxic effect on the human keratinocytes and on the 3D reconstructed human epidermis. There were also no significant changes in cell morphology. In conclusion, it is suggested that the acrylic removable appliance has a safety profile recommended for in vivo use.
Collapse
Affiliation(s)
- Stefania Dinu
- Department of Pedodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 No., Revolutiei 1989 Bv., 300041 Timisoara, Romania; (S.D.); (M.P.)
- Pediatric Dentistry Research Center, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 No., Revolutiei Bv., 300041 Timisoara, Romania
| | - Emanuela Lidia Craciunescu
- Department of Prostheses Technology and Dental Material, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 No., Revolutiei 1989 Bv., 300041 Timisoara, Romania;
- Romania Research Center in Dental Medicine Using Conventional and Alternative Technologies, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 No., Revolutiei Bv., 300041 Timisoara, Romania
| | - Ioana Macasoi
- Department of Toxicology and Drug Industry, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 2nd Eftimie Murgu Sq., 300041 Timisoara, Romania; (I.M.); (I.M.); (A.D.); (A.M.); (C.D.)
- Research Center for Pharmaco-Toxicological Evaluations, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Doina Chioran
- Department of Dento-Alveolar Surgery, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 Revolutiei 1989 Ave., 300070 Timisoara, Romania
- Correspondence: (D.C.); (M.R.)
| | - Mircea Rivis
- Department of Anesthesiology and Sedation in Dentistry, Dento-Alveolar Surgery, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 2nd Eftimie Murgu Sq., 300041 Timisoara, Romania
- Correspondence: (D.C.); (M.R.)
| | - Daliborca Vlad
- Department of Pharmacology and Biochemistry-Pharmacology, Faculty of Medicine, Victor Babes University of Medicine and Pharmacy, 2nd Eftimie Murgu Sq., 300041 Timisoara, Romania;
| | - Raluca Adriana Milutinovici
- Department of Orthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 Revolutiei 1989 Ave., 300070 Timisoara, Romania;
- Orthodontic Research Center (ORTHO-CENTER), Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, Revolutiei Ave. 1989 No. 9, 300041 Timisoara, Romania
| | - Iasmina Marcovici
- Department of Toxicology and Drug Industry, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 2nd Eftimie Murgu Sq., 300041 Timisoara, Romania; (I.M.); (I.M.); (A.D.); (A.M.); (C.D.)
- Research Center for Pharmaco-Toxicological Evaluations, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Alina Dolghi
- Department of Toxicology and Drug Industry, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 2nd Eftimie Murgu Sq., 300041 Timisoara, Romania; (I.M.); (I.M.); (A.D.); (A.M.); (C.D.)
- Research Center for Pharmaco-Toxicological Evaluations, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Alina Moaca
- Department of Toxicology and Drug Industry, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 2nd Eftimie Murgu Sq., 300041 Timisoara, Romania; (I.M.); (I.M.); (A.D.); (A.M.); (C.D.)
- Research Center for Pharmaco-Toxicological Evaluations, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Dorin Cristian Dinu
- Family Dental Clinic, Private Practice, 24 Budapesta Str., 307160 Dumbravita, Romania;
| | - Cristina Dehelean
- Department of Toxicology and Drug Industry, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, 2nd Eftimie Murgu Sq., 300041 Timisoara, Romania; (I.M.); (I.M.); (A.D.); (A.M.); (C.D.)
- Research Center for Pharmaco-Toxicological Evaluations, Faculty of Pharmacy, Victor Babes University of Medicine and Pharmacy, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Malina Popa
- Department of Pedodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 No., Revolutiei 1989 Bv., 300041 Timisoara, Romania; (S.D.); (M.P.)
- Pediatric Dentistry Research Center, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy, 9 No., Revolutiei Bv., 300041 Timisoara, Romania
| |
Collapse
|
8
|
Kovač V, Bergant M, Ščančar J, Primožič J, Jamnik P, Poljšak B. Causation of Oxidative Stress and Defense Response of a Yeast Cell Model after Treatment with Orthodontic Alloys Consisting of Metal Ions. Antioxidants (Basel) 2021; 11:antiox11010063. [PMID: 35052565 PMCID: PMC8772795 DOI: 10.3390/antiox11010063] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/17/2021] [Accepted: 12/23/2021] [Indexed: 11/16/2022] Open
Abstract
Misaligned teeth have a tremendous impact on oral and dental health, and the most efficient method of correcting the problem is orthodontic treatment with orthodontic appliances. The study was conducted to investigate the metal composition of selected orthodontic alloys, the release of metal ions, and the oxidative consequences that the metal ions may cause in the cell. Different sets of archwires, stainless steel brackets, and molar bands were incubated in artificial saliva for 90 days. The composition of each orthodontic material and quantification of the concentration of metal ions released were evaluated. Metal ion mixtures were prepared to determine the occurrence of oxidative stress, antioxidant enzyme defense system, and oxidative damage to proteins. The beta titanium alloy released the fewest metal ions and did not cause oxidative stress or protein damage. The metal ions from stainless steel and the cobalt-chromium alloy can cause oxidative stress and protein damage only at high concentrations. All metal ions from orthodontic alloys alter the activity of antioxidant enzymes in some way. The determined amounts of metal ions released from orthodontic appliances in a simulated oral environment are still below the maximum tolerated dose, and the concentrations of released metal ions are not capable of inducing oxidative stress, although some changes in antioxidant enzyme activity were observed at these concentrations.
Collapse
Affiliation(s)
- Vito Kovač
- Faculty of Health Sciences, University of Ljubljana, Zdravstvena pot 5, 1000 Ljubljana, Slovenia;
| | - Matic Bergant
- Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (M.B.); (J.Š.)
| | - Janez Ščančar
- Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (M.B.); (J.Š.)
| | - Jasmina Primožič
- Department of Dental and Jaw Orthopedics, Medical Faculty, University of Ljubljana, Hrvatski trg 6, 1000 Ljubljana, Slovenia;
| | - Polona Jamnik
- Biotechnical Faculty, University of Ljubljana, Jamnikarjeva ulica 101, 1000 Ljubljana, Slovenia;
| | - Borut Poljšak
- Faculty of Health Sciences, University of Ljubljana, Zdravstvena pot 5, 1000 Ljubljana, Slovenia;
- Correspondence:
| |
Collapse
|
9
|
Abstract
Stainless steels (SS) are the most-used alloys for manufacturing fixed orthodontic appliances due to their attractive set of mechanical properties, biocompatibility, and high corrosion resistance. Nevertheless, during regular orthodontic treatments–taking at least around 2 years–the intraoral environment inevitably degrades these bioalloys, releasing metallic ions into the oral cavity. In the first part of this in vitro study, the corrosion resistance of commercial SS appliances (brackets, tubes, and bands) was evaluated in Fusayama-Meyer artificial saliva at pH values of 2.3 and 6.8 over the course of 30 days. As expected, the results corroborated that salivary pH highly influences corrosion behaviour. Released Ni, Cr, and Fe were within dietary intake values. In the second part, a novel approach for oral corrosion prevention based on the chemical inertness of DLC materials is presented. SS surfaces were functionalized with biocompatible a-C:H-sputtered coatings and submitted to the same experimental conditions. The anticorrosion ability of this system was demonstrated, preventing the pitting corrosion that occurred on the SS substrates. Despite the galvanic coupling effect due to the presence of the Cr-based interlayer, this study enhanced the potential use of the reactive sputter-deposited a-C:H coatings in orthodontics.
Collapse
|
10
|
Bacterial Exposure to Nickel: Influence on Adhesion and Biofilm Formation on Orthodontic Archwires and Sensitivity to Antimicrobial Agents. MATERIALS 2021; 14:ma14164603. [PMID: 34443123 PMCID: PMC8397954 DOI: 10.3390/ma14164603] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 08/12/2021] [Accepted: 08/13/2021] [Indexed: 01/11/2023]
Abstract
The presence of nickel could modify bacterial behavior and susceptibility to antimicrobial agents. Adhesion and biofilm formation on orthodontic archwires can be a source of bacterial colonization and possible health hazards. Staphylococcus aureus was subjected to exposure and adaptation to various sub-inhibitory concentrations of nickel. Five strains of bacteria adapted to nickel in concentrations of 62.5-1000 μg/mL were tested for adhesion and biofilm formation on nickel-titanium archwires. Archwires were previously incubated in artificial saliva. Bacteria were incubated with orthodontic wire with stirring for 4 h (adhesion) and 24 h (biofilm formation). The number of adherent bacteria was determined after sonication and cultivation on the Muller-Hinton agar. Disk diffusion method was performed on all bacteria to assess the differences in antimicrobial susceptibility. Bacteria adapted to lower concentrations of nickel adhered better to nickel-titanium than strains adapted to higher concentrations of nickel (p < 0.05). Biofilm formation was highest in strains adapted to 250 and 500 μg/mL of nickel (p < 0.05). The highest biofilm biomass was measured for strains adapted to 250 μg/mL, followed by those adapted to 1000 μg/mL. Bacteria adapted to lower concentrations of nickel demonstrated lower inhibition zone diameters in the disk diffusion method (p < 0.05), indicating increased antimicrobial resistance. In conclusion, bacteria adapted to 250 μg/mL of nickel ions adhered better, demonstrated higher biofilm formation and often had higher antimicrobial resistance than other adapted and non-adapted strains.
Collapse
|
11
|
Papaioannou P, Sütel M, Hüsker K, Müller WD, Bartzela T. A New Setup for Simulating the Corrosion Behavior of Orthodontic Wires. MATERIALS (BASEL, SWITZERLAND) 2021; 14:3758. [PMID: 34279329 PMCID: PMC8269849 DOI: 10.3390/ma14133758] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/28/2021] [Accepted: 06/29/2021] [Indexed: 11/17/2022]
Abstract
The aim of this study was to create a new reliable setup to evaluate commercially available orthodontic wires used during orthodontic treatment. The setup includes various techniques applied for testing metal alloy materials. The materials were tested under extreme conditions to simulate their behavior in the mouth. The alloy composition of each wire was tested. The electrochemical (EC) testing and characterization of the corrosion performance of the wires was calculated by the electrochemical curves at pH = 1 in two different applied potentials to test the reaction of the material. The liquid collected after the EC measurements was analyzed by inductively coupled plasma-mass spectrometry (ICP-MS) to verify the reliability of the EC curves and for a more accurate evaluation of the corrosion behavior of the wires. Therefore, the EC measurements were compared to the actual values obtained from the released ions found in the solution. At the end, a surface analysis was performed to detect corrosion on the wires. In conclusion, this study developed a setup to test and better understand the corrosion behavior and ion release of the orthodontic wires, metal alloy dental materials, and other metals used in the oral cavity. This method can contribute to dental material selection in patients with underlying health conditions.
Collapse
Affiliation(s)
- Polydefkis Papaioannou
- Department of Orthodontics, Dentofacial Orthopedics, and Pedodontics, Charité Center for Oral Health Sciences, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of Health, Assmannshauser Str. 4–6, 19147 Berlin, Germany;
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Center for Oral Health Sciences, Dental Materials and Biomaterial Research, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of HealthAßmannshauser Str. 4–6, 14197 Berlin, Germany; (M.S.); (W.-D.M.)
| | - Mona Sütel
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Center for Oral Health Sciences, Dental Materials and Biomaterial Research, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of HealthAßmannshauser Str. 4–6, 14197 Berlin, Germany; (M.S.); (W.-D.M.)
| | - Katrin Hüsker
- Department of Immunology, IMD Institute of Medical Diagnostics Berlin-Potsdam GbR, 12247 Berlin, Germany;
| | - Wolf-Dieter Müller
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Center for Oral Health Sciences, Dental Materials and Biomaterial Research, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of HealthAßmannshauser Str. 4–6, 14197 Berlin, Germany; (M.S.); (W.-D.M.)
| | - Theodosia Bartzela
- Department of Orthodontics, Dentofacial Orthopedics, and Pedodontics, Charité Center for Oral Health Sciences, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and the Berlin Institute of Health, Assmannshauser Str. 4–6, 19147 Berlin, Germany;
| |
Collapse
|
12
|
Campos Zeffa A, Dias BG, Silva DCMS, Rotta LO, Jussiani EI, Andrello AC, de Paula Ramos S. Influence of Conventional or Invisalign Orthodontic Treatment on Mineral and Trace Element Salivary Levels: Longitudinal Study with Total Reflection X-ray Fluorescence. Biol Trace Elem Res 2021; 199:2565-2572. [PMID: 32946034 DOI: 10.1007/s12011-020-02396-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Accepted: 09/14/2020] [Indexed: 10/23/2022]
Abstract
This work aimed to evaluate the salivary concentration of chemical elements in patients undergoing orthodontic treatment with fixed orthodontic appliances and removable aligners. Twelve Angle Class I and II orthodontic patients undergoing treatment with conventional fixed appliances and 15 patients treated with removable aligners provided unstimulated whole saliva samples before treatment (pre) and after 3 months of treatment (post). The concentration and secretion rate of chemical elements in saliva were determined by total reflection X-ray fluorescence. Differences from pre to post and between groups were determined with the paired T test or Wilcoxon test, and two-way ANOVA, considering P < 0.05. The concentrations of S, Cl, and K decreased, while Zn increased significantly (P < 0.05) between pre and post treatment with the fixed appliance treatment. The salivary secretion rate of S was decreased from pre to post in the fixed appliance group. No differences in the concentration and secretion rate of chemical elements were detected from pre to post in the Invisalign group. Fe secretion rate presented an interaction between time and treatment, with lower secretion at post (P = 0.02) in the Invisalign group. Increased Br secretion rate and decreased Rb, Fe, P, and K in Invisalign patients suggested a better salivary electrolyte profile regarding periodontal bone remodeling. No significant alterations in ions associated with metal corrosion and inflammatory reactions were detected in orthodontic patients under dental plaque control.
Collapse
Affiliation(s)
- Aline Campos Zeffa
- Research group in Tissue Regeneration, Adaptation and Repair - State University of Londrina, Londrina, PR, 86057-970, Brazil
| | - Bianca Gonçalves Dias
- Research group in Tissue Regeneration, Adaptation and Repair - State University of Londrina, Londrina, PR, 86057-970, Brazil
| | | | | | | | | | - Solange de Paula Ramos
- Research group in Tissue Regeneration, Adaptation and Repair - State University of Londrina, Londrina, PR, 86057-970, Brazil.
| |
Collapse
|
13
|
Wepner L, Färber HA, Jaensch A, Weber A, Heuser F, Keilig L, Singer L, Bourauel CP. In Vitro Ion Release of Wires in Removable Orthodontic Appliances. MATERIALS 2021; 14:ma14123402. [PMID: 34205381 PMCID: PMC8234825 DOI: 10.3390/ma14123402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 06/09/2021] [Accepted: 06/15/2021] [Indexed: 12/20/2022]
Abstract
Various orthodontic wire compositions and configurations are present on the market for removable appliances; however, there have still been only few studies focusing on the effect of resin color and additives such as glitter on corrosion of metallic wires under different conditions. Thus, the aim of the study was to compare concentrations of released ions (aluminium, chromium, nickel) in a corrosive medium under three different conditions: non-loaded wires, loaded wires, and non-loaded wires treated with Kukis® cleaning tablets. Six different wires made of three types of steel alloy were embedded in PMMA resin leaving one centimetre of each wire emerging from the resin to come into contact with the corrosive medium. Glitter particles were added to half of the produced test specimens. For the unloaded test series, five specimens of each group were covered in a petri dish with 50 mL of corrosive medium (pH 2.3) following EN-ISO 10271 for seven days at 37 °C. The wires for the mechanically loaded test specimens overlapped the resin by 5 cm and were clamped into a time-switched electric drive for a defined period of time before the samples were taken after a testing time of 7 days. In the third group, unloaded test specimens were transferred from their petri dishes into the prepared Kukis® solution every 24 h before being stored in the corrosive medium. Inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify the specific ions in the corrosive solution. Statistical analysis showed that the mechanical loading of all wires could significantly raise the diffusion of ions into the corrosive medium. The colour of the resin did not affect the concentration of the released ions. The Kukis® cleaning tabs could not lower the corrosion of the tested metals, as some of the wires were corroded even more using the brace cleanser. Glitter-containing test specimens showed significantly higher amounts of aluminium. Mechanical loading as well as the presence of glitter particles in the resin significantly affected ion concentrations.
Collapse
Affiliation(s)
- Lena Wepner
- Oral Technology, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany; (L.W.); (A.W.); (L.K.); (L.S.)
| | - Harald Andreas Färber
- Institute for Hygiene and Public Health, Medical Faculty, University of Bonn, 53127 Bonn, Germany; (H.A.F.); (A.J.)
| | - Andreas Jaensch
- Institute for Hygiene and Public Health, Medical Faculty, University of Bonn, 53127 Bonn, Germany; (H.A.F.); (A.J.)
| | - Anna Weber
- Oral Technology, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany; (L.W.); (A.W.); (L.K.); (L.S.)
| | - Florian Heuser
- Department of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany;
| | - Ludger Keilig
- Oral Technology, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany; (L.W.); (A.W.); (L.K.); (L.S.)
| | - Lamia Singer
- Oral Technology, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany; (L.W.); (A.W.); (L.K.); (L.S.)
| | - Christoph Peter Bourauel
- Oral Technology, Dental School, Medical Faculty, University of Bonn, 53111 Bonn, Germany; (L.W.); (A.W.); (L.K.); (L.S.)
- Correspondence:
| |
Collapse
|
14
|
Comparison of Cell Viability and Chemical Composition of Six Latest Generation Orthodontic Wires. Int J Biomater 2021; 2021:8885290. [PMID: 33574848 PMCID: PMC7861923 DOI: 10.1155/2021/8885290] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 12/14/2020] [Accepted: 01/16/2021] [Indexed: 11/17/2022] Open
Abstract
Orthodontic wires are made of alloys containing different metals, including nickel. It is important to evaluate their biocompatibility prior to use, owing to their long-term use in patients. This in vitro study compared the cytotoxicity and chemical composition of six latest orthodontic wires: Fantasia®, Tanzo®, FLI®, NT3®, DuoForce®, and Gummetal®. The before-use group consisted of wires that were not used in the mouth, and the after-use group consisted of wires that were used in the mouth for two months. The wires were placed in contact with human gingival fibroblasts (HGF) for 72 h, and cytotoxicity was determined using the resazurin test. The chemical composition and surface characterisation were evaluated by spectrometry and scanning electron microscopy. The groups were compared using ANOVA and Kruskal–Wallis test. Only the FLI® wires produced a 36% reduction in HGF viability (p < 0.05) and presented greater irregularities and loss of polymer structure. After-use wires showed a significant reduction in the percentage of nickel and the appearance of new elements (oxygen and carbon). Therefore, it can be concluded that no toxic ion release was noticed in this study. Rhodium-coated wires were more stable than PTFE-coated wires, and only the FLI® wires showed a slight cytotoxic effect.
Collapse
|
15
|
Kovač V, Poljšak B, Primožič J, Jamnik P. Are Metal Ions That Make up Orthodontic Alloys Cytotoxic, and Do They Induce Oxidative Stress in a Yeast Cell Model? Int J Mol Sci 2020; 21:ijms21217993. [PMID: 33121155 PMCID: PMC7662645 DOI: 10.3390/ijms21217993] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Accepted: 10/26/2020] [Indexed: 12/17/2022] Open
Abstract
Compositions of stainless steel, nickel-titanium, cobalt-chromium and β-titanium orthodontic alloys were simulated with mixtures of Fe, Ni, Cr, Co, Ti and Mo metal ions as potential oxidative stress-triggering agents. Wild-type yeast Saccharomyces cerevisiae and two mutants ΔSod1 and ΔCtt1 were used as model organisms to assess the cytotoxicity and oxidative stress occurrence. Metal mixtures at concentrations of 1, 10, 100 and 1000 µM were prepared out of metal chlorides and used to treat yeast cells for 24 h. Every simulated orthodontic alloy at 1000 µM was cytotoxic, and, in the case of cobalt-chromium alloy, even 100 µM was cytotoxic. Reactive oxygen species and oxidative damage were detected for stainless steel and both cobalt-chromium alloys at 1000 µM in wild-type yeast and 100 µM in the ΔSod1 and ΔCtt1 mutants. Simulated nickel-titanium and β-titanium alloy did not induce oxidative stress in any of the tested strains.
Collapse
Affiliation(s)
- Vito Kovač
- Faculty of Health Sciences, University of Ljubljana, Zdravstvena pot 5, 1000 Ljubljana, Slovenia; (V.K.); (B.P.)
| | - Borut Poljšak
- Faculty of Health Sciences, University of Ljubljana, Zdravstvena pot 5, 1000 Ljubljana, Slovenia; (V.K.); (B.P.)
| | - Jasmina Primožič
- Medical Faculty, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia;
| | - Polona Jamnik
- Biotechnical Faculty, University of Ljubljana, Jamnikarjeva ulica 101, 1000 Ljubljana, Slovenia
- Correspondence: ; Tel.: +386-1-3203-729
| |
Collapse
|
16
|
Olszewska A, Hanć A, Barałkiewicz D, Rzymski P. Metals and Metalloids Release from Orthodontic Elastomeric and Stainless Steel Ligatures: In Vitro Risk Assessment of Human Exposure. Biol Trace Elem Res 2020; 196:646-653. [PMID: 31686396 PMCID: PMC7306017 DOI: 10.1007/s12011-019-01936-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 10/14/2019] [Indexed: 02/07/2023]
Abstract
Elastomeric ligatures are increasingly used as a part of esthetic orthodontic treatment, particularly in children. The aim of the present study was to experimentally test whether these appliances may contribute to exposure to toxic elements. In the present study, elastomeric ligatures (ELs) were incubated in artificial human saliva for 1 month (a typical period of their use) and the release of 21 metals (Ba, Cd, Co, Cr, Cu, Fe, Li, Mn, Mg, Mo, Ni, Pb, Rb, Tl, Ti, Sb, Sr, Sn, Zn, U, V) and 2 metalloids (As and Ge) was studied using inductively coupled plasma-mass spectrometry. For comparison, stainless steel ligatures (SLs) were incubated for 1, 3, and 6 months (since sometimes their use is prolonged) under similar conditions. The determined metal levels were compared to the corresponding safety limits for human exposure. During 1 month, the ELs released Cd, Co, Cr, Mn, Ni, and Sn at total mean ± SD level of 0.31 ± 0.09, 0.98 ± 0.30, 3.96 ± 1.31, 14.7 ± 8.5, 13.8 ± 4.8, and 49.5 ± 27.7 μg, respectively. Other elements were always below the detection limits. In case of SL, the release of Co, Cr, Fe, Ni, Mn, and Sn was observed, and the determined values increased over the studied period. After 6 months, their total mean ± SD levels amounted to 28.6 ± 0.2, 21.7 ± 0.2, 623.5 ± 3.0, 1152.7 ± 1.8, 5.5 ± 0.3, and 22.6 ± 0.2 μg, respectively. The released metal levels from both ligature types were always below safety limits. The release of Ni from SL during 6 months would constitute 5.0 and 11.5% of tolerable intake in adults and children, respectively. The results of this in vitro study highlight that the use of ligatures in orthodontic treatment can be considered safe in terms of metal exposure although elastic ligatures replaced on a monthly basis appear to be advantageous in comparison to the prolonged use of stainless steel appliances.
Collapse
Affiliation(s)
- Aneta Olszewska
- Department of Facial Malformation, Poznan University of Medical Sciences, Poznań, Poland
| | - Anetta Hanć
- Department of Trace Element Analysis by Spectrometry Method, Faculty of Chemistry, Adam Mickiewicz University, Poznań, Poland
| | - Danuta Barałkiewicz
- Department of Trace Element Analysis by Spectrometry Method, Faculty of Chemistry, Adam Mickiewicz University, Poznań, Poland
| | - Piotr Rzymski
- Department of Environmental Medicine, Poznan University of Medical Sciences, Poznań, Poland.
| |
Collapse
|
17
|
Moghadam MG, Hoshyar R, Mikulewicz M, Chojnacka K, Bjørklund G, Pen JJ, Azadi NA, Pirsaheb M, Dashtaki M, Mansouri B. Biomonitorization of metal ions in the serum of Iranian patients treated with fixed orthodontic appliances in comparison with controls in eastern Iran. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2019; 26:33373-33386. [PMID: 31522402 DOI: 10.1007/s11356-019-06414-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 09/03/2019] [Indexed: 06/10/2023]
Abstract
The present study aimed to assess the level of metal ions [chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), and zinc (Zn)] in the serum of patients with fixed orthodontic appliances. One hundred samples (32 males, 68 females) were collected from patients undergoing fixed orthodontic treatment for different periods. A reference (control) group (24 males, 16 females) who had no appliances was used to properly evaluate the changes in the level of these elements in orthodontic appliance users. The element concentrations were measured using inductively coupled plasma mass spectrometry (ICP-MS). Higher concentrations of metal ions (except for Cr) were found in the serum of the orthodontic group. Bivariate scatter plot showed a highly significant (p < 0.001) correlation between Ni and other elements. The duration of orthodontic treatment increased significantly the Ni levels whereas the bracket type was found to have no significant impact on altering the concentration level of metal ions. The results of the SEM-EDS showed a high variation in the level of metal ions in the brackets and wires. In conclusion, fixed orthodontic appliances increased serum levels of Ni, Zn, Mn, Fe, and Cu but did not change Cr levels.
Collapse
Affiliation(s)
| | - Reyhane Hoshyar
- Cellular and Molecular Research Center, Birjand University of Medical Sciences, Birjand, Iran
- Department of Microbiology and Molecular Genetics, Michigan State University, East Lansing, USA
| | - Marcin Mikulewicz
- Department of Dentofacial Orthopaedics and Orthodontics, Division of Facial Abnormalities, Medical University of Wrocław, Krakowska 26, 50-425, Wroclaw, Poland
| | - Katarzyna Chojnacka
- Department of Advanced Material Technologies, Faculty of Chemistry, Wroclaw University of Science and Technology, Wroclaw, Poland
| | - Geir Bjørklund
- Council for Nutritional and Environmental Medicine, Mo i Rana, Norway
| | - Joeri J Pen
- Diabetes Clinic, Department of Internal Medicine, UZ Brussel, Vrije Universiteit Brussel (VUB), Brussels, Belgium
- Department of Nutrition, UZ Brussel, Vrije Universiteit Brussel (VUB), Brussels, Belgium
| | - Nammam Ali Azadi
- Department of Biostatistics, Faculty of Public Health, Iran University of Medical Sciences, Tehran, Iran
| | - Maghdad Pirsaheb
- Research Center for Environmental Determinants of Health (RCEDH), Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Meysam Dashtaki
- Student Research Committee, Birjand University of Medical Sciences, Birjand, Iran
| | - Borhan Mansouri
- Substance Abuse Prevention Research Center, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran.
| |
Collapse
|