1
|
Zhao Y, Haworth A, Reynolds HM, Williams SG, Finnegan R, Rowshanfarzad P, Ebert MA. Towards optimal heterogeneous prostate radiotherapy dose prescriptions based on patient-specific or population-based biological features. Med Phys 2024; 51:3766-3781. [PMID: 38224317 DOI: 10.1002/mp.16936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Revised: 12/20/2023] [Accepted: 12/22/2023] [Indexed: 01/16/2024] Open
Abstract
BACKGROUND Escalation of prescribed dose in prostate cancer (PCa) radiotherapy enables improvement in tumor control at the expense of increased toxicity. Opportunities for reduction of treatment toxicity may emerge if more efficient dose escalation can be achieved by redistributing the prescribed dose distribution according to the known heterogeneous, spatially-varying characteristics of the disease. PURPOSE To examine the potential benefits, limitations and characteristics of heterogeneous boost dose redistribution in PCa radiotherapy based on patient-specific and population-based spatial maps of tumor biological features. METHOD High-resolution prostate histology images, from a cohort of 63 patients, annotated with tumor location and grade, provided patient-specific "maps" and a population-based "atlas" of cell density and tumor probability. Dose prescriptions were derived for each patient based on a heterogeneous redistribution of the boost dose to the intraprostatic lesions, with the prescription maximizing patient tumor control probability (TCP). The impact on TCP was assessed under scenarios where the distribution of population-based biological data was ignored, partially included, or fully included in prescription generation. Heterogeneous dose prescriptions were generated for three combinations of maps and atlas, and for conventional fractionation (CF), extreme hypo-fractionation (EH), moderate hypo-fractionation (MH), and whole Pelvic RT + SBRT Boost (WPRT + SBRT). The predicted efficacy of the heterogeneous prescriptions was compared with equivalent homogeneous dose prescriptions. RESULTS TCPs for heterogeneous dose prescriptions were generally higher than those for homogeneous dose prescriptions. TCP escalation by heterogeneous dose prescription was the largest for CF. When only using population-based atlas data, the generated heterogeneous dose prescriptions of 55 to 58 patients (out of 63) had a higher TCP than for the corresponding homogeneous dose prescriptions. The TCPs of the heterogeneous dose prescriptions generated with the population-based atlas and tumor probability maps did not differ significantly from those using patient-specific biological information. The generated heterogeneous dose prescriptions achieved significantly higher TCP than homogeneous dose prescriptions in the posterior section of the prostate. CONCLUSION Heterogeneous dose prescriptions generated via biologically-optimized dose redistribution can produce higher TCP than the homogeneous dose prescriptions for the majority of the patients in the studied cohort. For scenarios where patient-specific biological information was unavailable or partially available, the generated heterogeneous dose prescriptions can still achieve TCP improvement relative to homogeneous dose prescriptions.
Collapse
Affiliation(s)
- Yutong Zhao
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, Western Australia, Australia
| | - Annette Haworth
- Institute of Medical Physics, School of Physics, The University of Sydney, Camperdown, New South Wales, Australia
| | - Hayley M Reynolds
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Scott G Williams
- Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria, Australia
- Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
| | - Robert Finnegan
- Institute of Medical Physics, School of Physics, The University of Sydney, Camperdown, New South Wales, Australia
- Northern Sydney Cancer Centre, Royal North Shore Hospital, St Leonards, New South Wales, Australia
- Ingham Institute for Applied Medical Research, Liverpool, New South Wales, Australia
| | - Pejman Rowshanfarzad
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, Western Australia, Australia
| | - Martin A Ebert
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, Western Australia, Australia
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia, Australia
- 5D Clinics, Claremont, Western Australia, Australia
| |
Collapse
|
2
|
Zhao Y, Haworth A, Rowshanfarzad P, Ebert MA. Focal Boost in Prostate Cancer Radiotherapy: A Review of Planning Studies and Clinical Trials. Cancers (Basel) 2023; 15:4888. [PMID: 37835581 PMCID: PMC10572027 DOI: 10.3390/cancers15194888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 09/28/2023] [Accepted: 10/05/2023] [Indexed: 10/15/2023] Open
Abstract
BACKGROUND Focal boost radiotherapy was developed to deliver elevated doses to functional sub-volumes within a target. Such a technique was hypothesized to improve treatment outcomes without increasing toxicity in prostate cancer treatment. PURPOSE To summarize and evaluate the efficacy and variability of focal boost radiotherapy by reviewing focal boost planning studies and clinical trials that have been published in the last ten years. METHODS Published reports of focal boost radiotherapy, that specifically incorporate dose escalation to intra-prostatic lesions (IPLs), were reviewed and summarized. Correlations between acute/late ≥G2 genitourinary (GU) or gastrointestinal (GI) toxicity and clinical factors were determined by a meta-analysis. RESULTS By reviewing and summarizing 34 planning studies and 35 trials, a significant dose escalation to the GTV and thus higher tumor control of focal boost radiotherapy were reported consistently by all reviewed studies. Reviewed trials reported a not significant difference in toxicity between focal boost and conventional radiotherapy. Acute ≥G2 GU and late ≥G2 GI toxicities were reported the most and least prevalent, respectively, and a negative correlation was found between the rate of toxicity and proportion of low-risk or intermediate-risk patients in the cohort. CONCLUSION Focal boost prostate cancer radiotherapy has the potential to be a new standard of care.
Collapse
Affiliation(s)
- Yutong Zhao
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA 6009, Australia; (P.R.); (M.A.E.)
| | - Annette Haworth
- Institute of Medical Physics, School of Physics, The University of Sydney, Camperdown, NSW 2050, Australia;
| | - Pejman Rowshanfarzad
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA 6009, Australia; (P.R.); (M.A.E.)
- Centre for Advanced Technologies in Cancer Research (CATCR), Perth, WA 6000, Australia
| | - Martin A. Ebert
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA 6009, Australia; (P.R.); (M.A.E.)
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA 6009, Australia
- 5D Clinics, Claremont, WA 6010, Australia
- School of Medicine and Population Health, University of Wisconsin, Madison WI 53706, USA
| |
Collapse
|
3
|
Grigo J, Masitho S, Fautz HP, Voigt R, Schonath M, Oleszczuk A, Uder M, Heiss R, Fietkau R, Putz F, Bert C. Usability of magnetic resonance images acquired at a novel low-field 0.55 T scanner for brain radiotherapy treatment planning. Phys Imaging Radiat Oncol 2023; 25:100412. [PMID: 36969504 PMCID: PMC10037089 DOI: 10.1016/j.phro.2023.100412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 01/11/2023] [Accepted: 01/11/2023] [Indexed: 01/14/2023] Open
Abstract
Background and Purpose Low-field magnetic resonance imaging (MRI) may offer specific advantages over high-field MRI, e.g. lower susceptibility-dependent distortions and simpler installation. The study aim was to evaluate if a novel 0.55 T MRI scanner provides sufficient image accuracy and quality for radiotherapy (RT) treatment planning. Material and methods The geometric accuracy of images acquired at a low-field MRI scanner was evaluated in phantom measurements regarding gradient non-linearity-related distortions. Patient-induced B0-susceptibility changes were investigated via B0-field-mapping in ten volunteers. Patients were positioned in RT-setup using a 3D-printed insert for the head/neck-coil that was tested for sufficient signal-to-noise-ratio (SNR). The suitability of the MRI-system for detection of metastases was evaluated in eleven patients. In comparison to diagnostic images, acquired at ≥1.5 T, three physicians evaluated the detectability of metastases by counting them in low- and high-field-images, respectively. Results The phantom measurements showed a high imaging fidelity after 3D-distortion-correction with (1.2 ± 0.9) mm geometric distortion in 10 cm radius from isocentre. At the edges remaining distortions were greater than at 1.5 T. The mean susceptibility-induced distortions in the head were (0.05 ± 0.05) mm and maximum 0.69 mm. SNR analysis showed that optimised positioning of RT-patients without signal loss in the head/neck-coil was possible with the RT-insert. No significant differences (p = 0.48) in detectability of metastases were found. Conclusion The 0.55 T MRI system provided sufficiently geometrically accurate and high-resolution images that can be used for RT-planning for brain metastases. Hence, modern low-field MRI may contribute to simply access MRI for RT-planning after further investigations.
Collapse
|
4
|
Strnad V, Lotter M, Kreppner S, Fietkau R. Brachytherapy focal dose escalation using ultrasound based tissue characterization by patients with non-metastatic prostate cancer: Five-year results from single-center phase 2 trial. Brachytherapy 2022; 21:415-423. [PMID: 35396138 DOI: 10.1016/j.brachy.2022.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 01/11/2022] [Accepted: 02/21/2022] [Indexed: 11/20/2022]
Abstract
PURPOSE This prospective trial investigates side effects and efficacy of focal dose escalation with brachytherapy for patients with prostate cancer. METHODS AND MATERIALS In the Phase II, monocentric prospective trial 101 patients with low-/intermediate- and high-risk prostate cancer were enrolled between 2011 and 2013. Patients received either PDR-/HDR-brachytherapy alone with 86-90 Gy (EQD2, α/β = 3 Gy) or PDR-/HDR-brachytherapy as boost after external beam radiation therapy up to a total dose of 91-96 Gy (EQD2, α/β = 3 Gy). Taking place brachytherapy all patients received the simultaneous integrated focal boost to the intra-prostatic tumor lesions visible in computer-aided ultrasonography (HistoScanning™) - up to a total dose of 108-119 Gy (EQD2, α/β = 3 Gy). The primary endpoint was toxicity. Secondary endpoints were cumulative freedom from local recurrence, PSA-free survival, distant metastases-free survival, and overall survival. This trial is registered with ClinicalTrials.gov, number NCT01409876. RESULTS Median follow-up was 65 months. Late toxicity was generally low with only four patients scoring urinary grade 3 toxicity (4/101, 4%). Occurrence of any grade of late rectal toxicities was very low. We did not register any grade ≥2 of late rectal toxicities. The cumulative 5 years local recurrence rate (LRR) for all patients was 1%. Five years- biochemical disease-free survival estimates according Kaplan-Meier were 98,1% and 81,3% for low-/intermediate-risk and high-risk patients, respectively. Five years metastases-free survival estimates according Kaplan-Meier were 98,0% and 83,3% for all patients, low-/intermediate-risk and high-risk patients, respectively. CONCLUSIONS The 5 years-results from this Phase II Trial show that focal dose escalation with computer-aided ultrasonography and brachytherapy for patients with non-metastatic prostate cancer is safe and effective.
Collapse
Affiliation(s)
- Vratislav Strnad
- Department of Radiation Oncology, University Hospital Erlangen, Erlangen, Germany.
| | - Michael Lotter
- Department of Radiation Oncology, University Hospital Erlangen, Erlangen, Germany
| | - Stephan Kreppner
- Department of Radiation Oncology, University Hospital Erlangen, Erlangen, Germany
| | - Rainer Fietkau
- Department of Radiation Oncology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
5
|
Tamihardja J, Cirsi S, Kessler P, Razinskas G, Exner F, Richter A, Polat B, Flentje M. Cone beam CT-based dose accumulation and analysis of delivered dose to the dominant intraprostatic lesion in primary radiotherapy of prostate cancer. Radiat Oncol 2021; 16:205. [PMID: 34702305 PMCID: PMC8549146 DOI: 10.1186/s13014-021-01933-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 10/19/2021] [Indexed: 12/02/2022] Open
Abstract
Background Evaluation of delivered dose to the dominant intraprostatic lesion (DIL) for moderately hypofractionated radiotherapy of prostate cancer by cone beam computed tomography (CBCT)-based dose accumulation and target coverage analysis. Methods Twenty-three patients with localized prostate cancer treated with moderately hypofractionated prostate radiotherapy with simultaneous integrated boost (SIB) between December 2016 and February 2020 were retrospectively analyzed. Included patients were required to have an identifiable DIL on bi-parametric planning magnetic resonance imaging (MRI). After import into the RayStation treatment planning system and application of a step-wise density override, the fractional doses were computed on each CBCT and were consecutively mapped onto the planning CT via a deformation vector field derived from deformable image registration. Fractional doses were accumulated for all CBCTs and interpolated for missing CBCTs, resulting in the delivered dose for PTVDIL, PTVBoost, PTV, and the organs at risk. The location of the index lesions was recorded according to the sector map of the Prostate Imaging Reporting and Data System (PIRADS) Version 2.1. Target coverage of the index lesions was evaluated and stratified for location. Results In total, 338 CBCTs were available for analysis. Dose accumulation target coverage of PTVDIL, PTVBoost, and PTV was excellent and no cases of underdosage in DMean, D95%, D02%, and D98% could be detected. Delivered rectum DMean did not significantly differ from the planned dose. Bladder mean DMean was higher than planned with 19.4 ± 7.4 Gy versus 18.8 ± 7.5 Gy, p < 0.001. The penile bulb showed a decreased delivered mean DMean with 29.1 ± 14.0 Gy versus 29.8 ± 14.4 Gy, p < 0.001. Dorsal DILs, defined as DILs in the posterior medial peripheral zone of the prostate, showed a significantly lower delivered dose with a mean DMean difference of 2.2 Gy (95% CI 1.3–3.1 Gy, p < 0.001) compared to ventral lesions. Conclusions CBCT-based dose accumulation showed an adequate delivered dose to the dominant intraprostatic lesion and organs at risk within planning limits. Cautious evaluation of the target coverage for index lesions adjacent to the rectum is warranted to avoid underdosage.
Collapse
Affiliation(s)
- Jörg Tamihardja
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany.
| | - Sinan Cirsi
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany
| | - Patrick Kessler
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany
| | - Gary Razinskas
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany
| | - Florian Exner
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany
| | - Anne Richter
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany
| | - Bülent Polat
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany
| | - Michael Flentje
- Department of Radiation Oncology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany
| |
Collapse
|
6
|
Tamihardja J, Razinskas G, Exner F, Richter A, Kessler P, Weick S, Kraft J, Mantel F, Flentje M, Polat B. Comparison of treatment plans for hypofractionated high-dose prostate cancer radiotherapy using the Varian Halcyon and the Elekta Synergy platforms. J Appl Clin Med Phys 2021; 22:262-270. [PMID: 34351055 PMCID: PMC8425948 DOI: 10.1002/acm2.13380] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 06/17/2021] [Accepted: 07/16/2021] [Indexed: 01/23/2023] Open
Abstract
Purpose To compare radiotherapy plans between an O‐ring and a conventional C‐arm linac for hypofractionated high‐dose prostate radiotherapy in terms of plan quality, dose distribution, and quality assurance in a multi‐vendor environment. Methods Twenty prostate cancer treatment plans were irradiated on the O‐ring Varian Halcyon linac and were re‐optimized for the C‐arm Elekta Synergy Agility linac. Dose‐volume histogram metrics for target coverage and organ at risk dose, quality assurance, and monitor units were retrospectively compared. Patient‐specific quality assurance with ion chamber measurements, gamma index analysis, and portal dosimetry was performed using the Varian Portal Dosimetry system and the ArcCHECK® phantom (Sun Nuclear Corporation). Prostate‐only radiotherapy was delivered with simultaneous integrated boost (SIB) volumetric modulated arc therapy (VMAT) in 20 fractions of 2.5/3.0 Gy each. Results For both linacs, target coverage was excellent and plan quality comparable. Homogeneity in PTVBoost was high for Synergy as well as Halcyon with a mean homogeneity index of 0.07 ± 0.01 and 0.05 ± 0.01, respectively. Mean dose for the organs at risk rectum and bladder differed not significantly between the linacs but were higher for the femoral heads and penile bulb for Halcyon. Quality assurance showed no significant differences in terms of ArcCHECK gamma pass rates. Median pass rate for 3%/2 mm was 99.3% (96.7 to 99.8%) for Synergy and 99.8% (95.6 to 100%) for Halcyon. Agreement between calculated and measured dose was high with a median deviation of −0.6% (−1.7 to 0.8%) for Synergy and 0.2% (−0.6 to 2.3%) for Halcyon. Monitor units were higher for the Halcyon by approximately 20% (p < 0.001). Conclusion Hypofractionated high‐dose prostate cancer SIB VMAT on the Halcyon system is feasible with comparable plan quality in reference to a standard C‐arm Elekta Synergy linac.
Collapse
Affiliation(s)
- Jörg Tamihardja
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Gary Razinskas
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Florian Exner
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Anne Richter
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Patrick Kessler
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Stefan Weick
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Johannes Kraft
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Frederick Mantel
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Michael Flentje
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| | - Bülent Polat
- Department of Radiation Oncology, University of Würzburg, Würzburg, Germany
| |
Collapse
|
7
|
Evaluation of the influence of susceptibility-induced magnetic field distortions on the precision of contouring intracranial organs at risk for stereotactic radiosurgery. Phys Imaging Radiat Oncol 2021; 15:91-97. [PMID: 33458332 PMCID: PMC7807629 DOI: 10.1016/j.phro.2020.08.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 07/31/2020] [Accepted: 08/03/2020] [Indexed: 11/23/2022] Open
Abstract
45 data sets (18 on a 1.5 T MR and 27 on a 3 T MR) were evaluated for susceptibility induced distortions. Maximum distortions of up to 1.7 mm were found for organs at risk in standard diagnostic settings. Median distortions ranged between 0.1 and 0.2 mm for all organs at risk. Active shimming was estimated to reduce distortions by a factor of 2.3 to 2.9. A safety margin of 1 mm would have encompassed 99.8% of the distortions.
Background and purpose Magnetic resonance imaging (MRI) is a crucial factor in optimal treatment planning for stereotactic radiosurgery. To further the awareness of possible errors in MRI, this work aimed to investigate the magnitude of susceptibility induced MRI distortions for intracranial organs at risk (OARs) and test the effectiveness of actively shimming these distortions. Materials and methods Distortion maps for 45 exams of 42 patients (18 on a 1.5 T MRI scanner, 27 on a 3 T MRI scanner) were calculated based on a high-bandwidth double-echo gradient echo sequence. The investigated OARs were brainstem, chiasm, eyes, and optic nerves. The influence of active shimming was investigated by comparing unshimmed 1.5 T data with shimmed 3 T data and comparing the results to a model based prediction. Results The median distortion for the different OARs was found to be between 0.13 and 0.18 mm for 1.5 T and between 0.11 and 0.13 mm for 3 T. The maximum distortion was found to be between 1.3 and 1.7 mm for 1.5 T and between 1.1 and 1.4 mm for 3 T. The variation of values was much higher for 1.5 T than for 3 T across all investigated OARs. Active shimming was found to reduce distortions by a factor of 2.3 to 2.9 compared to the expected values. Conclusions Using a safety margin for OARs of 1 mm would have encompassed 99.8% of the distortions. Since distortions are inversely proportional to the readout bandwidth, they can be further reduced by increasing the bandwidth. Additional error sources like gradient nonlinearities need to be addressed separately.
Collapse
|
8
|
Implementation of a dedicated 1.5 T MR scanner for radiotherapy treatment planning featuring a novel high-channel coil setup for brain imaging in treatment position. Strahlenther Onkol 2020; 197:246-256. [PMID: 33103231 PMCID: PMC7892740 DOI: 10.1007/s00066-020-01703-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 09/29/2020] [Indexed: 12/17/2022]
Abstract
Purpose To share our experiences in implementing a dedicated magnetic resonance (MR) scanner for radiotherapy (RT) treatment planning using a novel coil setup for brain imaging in treatment position as well as to present developed core protocols with sequences specifically tuned for brain and prostate RT treatment planning. Materials and methods Our novel setup consists of two large 18-channel flexible coils and a specifically designed wooden mask holder mounted on a flat tabletop overlay, which allows patients to be measured in treatment position with mask immobilization. The signal-to-noise ratio (SNR) of this setup was compared to the vendor-provided flexible coil RT setup and the standard setup for diagnostic radiology. The occurrence of motion artifacts was quantified. To develop magnetic resonance imaging (MRI) protocols, we formulated site- and disease-specific clinical objectives. Results Our novel setup showed mean SNR of 163 ± 28 anteriorly, 104 ± 23 centrally, and 78 ± 14 posteriorly compared to 84 ± 8 and 102 ± 22 anteriorly, 68 ± 6 and 95 ± 20 centrally, and 56 ± 7 and 119 ± 23 posteriorly for the vendor-provided and diagnostic setup, respectively. All differences were significant (p > 0.05). Image quality of our novel setup was judged suitable for contouring by expert-based assessment. Motion artifacts were found in 8/60 patients in the diagnostic setup, whereas none were found for patients in the RT setup. Site-specific core protocols were designed to minimize distortions while optimizing tissue contrast and 3D resolution according to indication-specific objectives. Conclusion We present a novel setup for high-quality imaging in treatment position that allows use of several immobilization systems enabling MR-only workflows, which could reduce unnecessary dose and registration inaccuracies. Electronic supplementary material The online version of this article (10.1007/s00066-020-01703-y) contains supplementary material, which is available to authorized users.
Collapse
|
9
|
Tamihardja J, Schortmann M, Lawrenz I, Weick S, Bratengeier K, Flentje M, Guckenberger M, Polat B. Moderately hypofractionated radiotherapy for localized prostate cancer: updated long-term outcome and toxicity analysis. Strahlenther Onkol 2020; 197:124-132. [PMID: 32833036 PMCID: PMC7840645 DOI: 10.1007/s00066-020-01678-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 08/03/2020] [Indexed: 12/24/2022]
Abstract
PURPOSE Evaluation of long-term outcome and toxicity of moderately hypofractionated radiotherapy using intensity-modulated radiotherapy (IMRT) with simultaneous integrated boost treatment planning and cone beam CT-based image guidance for localized prostate cancer. METHODS Between 2005 and 2015, 346 consecutive patients with localized prostate cancer received primary radiotherapy using cone beam CT-based image-guided intensity-modulated radiotherapy (IG-IMRT) and volumetric modulated arc therapy (IG-VMAT) with a simultaneous integrated boost (SIB). Total doses of 73.9 Gy (n = 44) and 76.2 Gy (n = 302) to the high-dose PTV were delivered in 32 and 33 fractions, respectively. The low-dose PTV received a dose (D95) of 60.06 Gy in single doses of 1.82 Gy. The pelvic lymph nodes were treated in 91 high-risk patients to 45.5 Gy (D95). RESULTS Median follow-up was 61.8 months. The 5‑year biochemical relapse-free survival (bRFS) was 85.4% for all patients and 93.3, 87.4, and 79.4% for low-, intermediate-, and high-risk disease, respectively. The 5‑year prostate cancer-specific survival (PSS) was 94.8% for all patients and 98.7, 98.9, 89.3% for low-, intermediate-, and high-risk disease, respectively. The 5‑year and 10-year overall survival rates were 83.8 and 66.3% and the 5‑year and 10-year freedom from distant metastasis rates were 92.2 and 88.0%, respectively. Cumulative 5‑year late GU toxicity and late GI toxicity grade ≥2 was observed in 26.3 and 12.1% of the patients, respectively. Cumulative 5‑year late grade 3 GU/GI toxicity occurred in 4.0/1.2%. CONCLUSION Moderately hypofractionated radiotherapy using SIB treatment planning and cone beam CT image guidance resulted in high biochemical control and survival with low rates of late toxicity.
Collapse
Affiliation(s)
- Jörg Tamihardja
- Department of Radiation Oncology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg, Germany.
| | - Max Schortmann
- Department of Radiation Oncology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg, Germany
| | - Ingulf Lawrenz
- Department of Radiation Oncology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg, Germany
| | - Stefan Weick
- Department of Radiation Oncology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg, Germany
| | - Klaus Bratengeier
- Department of Radiation Oncology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg, Germany
| | - Michael Flentje
- Department of Radiation Oncology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg, Germany
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Bülent Polat
- Department of Radiation Oncology, University Hospital Wuerzburg, University of Wuerzburg, Wuerzburg, Germany
| |
Collapse
|
10
|
Beer L, Polanec SH, Baltzer PAT, Schatzl G, Georg D, Schestak C, Dutschke A, Herrmann H, Mazal P, Brendel AK, Shariat SF, Ringl H, Helbich TH, Apfaltrer P. 4D perfusion CT of prostate cancer for image-guided radiotherapy planning: A proof of concept study. PLoS One 2019; 14:e0225673. [PMID: 31856177 PMCID: PMC6922381 DOI: 10.1371/journal.pone.0225673] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Accepted: 11/08/2019] [Indexed: 12/26/2022] Open
Abstract
Purpose Advanced forms of prostate cancer (PCa) radiotherapy with either external beam therapy or brachytherapy delivery techniques aim for a focal boost and thus require accurate lesion localization and lesion segmentation for subsequent treatment planning. This study prospectively evaluated dynamic contrast-enhanced computed tomography (DCE-CT) for the detection of prostate cancer lesions in the peripheral zone (PZ) using qualitative and quantitative image analysis compared to multiparametric magnet resonance imaging (mpMRI) of the prostate. Methods With local ethics committee approval, 14 patients (mean age, 67 years; range, 57–78 years; PSA, mean 8.1 ng/ml; range, 3.5–26.0) underwent DCE-CT, as well as mpMRI of the prostate, including standard T2, diffusion-weighted imaging (DWI), and DCE-MRI sequences followed by transrectal in-bore MRI-guided prostate biopsy. Maximum intensity projections (MIP) and DCE-CT perfusion parameters (CTP) were compared between healthy and malignant tissue. Two radiologists independently rated image quality and the tumor lesion delineation quality of PCa using a five-point ordinal scale. MIP and CTP were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Results The PCa detection rate ranged between 57 to 79% for the two readers for DCE-CT and was 92% for DCE-MRI. DCE-CT perfusion parameters in PCa tissue in the PZ were significantly different compared to regular prostate tissue and benign lesions. Image quality and lesion visibility were comparable between DCE-CT and DCE-MRI (VGC: AUC 0.612 and 0.651, p>0.05). Conclusion Our preliminary results suggest that it is feasible to use DCE-CT for identification and visualization, and subsequent segmentation for focal radiotherapy approaches to PCa.
Collapse
Affiliation(s)
- Lucian Beer
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- Department of Radiology and Cancer Research UK Cambridge Center, Cambridge, United Kingdom
| | - Stephan H. Polanec
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Pascal A. T. Baltzer
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Georg Schatzl
- Department of Urology, Medical University of Vienna, Vienna, Austria
| | - Dietmar Georg
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University Vienna, Austria
| | - Christian Schestak
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Anja Dutschke
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Harald Herrmann
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Peter Mazal
- Clinical Institute of Pathology, Medical University of Vienna, Vienna, Austria
| | | | | | - Helmut Ringl
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Thomas H. Helbich
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Paul Apfaltrer
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- Department of Neuroradiology, University Medical Center Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany
- * E-mail:
| |
Collapse
|