1
|
Lee H, Kim J, Joo S, Na SH, Lee S, Ko SB, Lee J, Oh SY, Ha EJ, Ryu HG. The effect of audiovisual feedback of monitor/defibrillators on percentage of appropriate compression depth and rate during cardiopulmonary resuscitation. BMC Anesthesiol 2023; 23:334. [PMID: 37798642 PMCID: PMC10552289 DOI: 10.1186/s12871-023-02304-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 09/29/2023] [Indexed: 10/07/2023] Open
Abstract
BACKGROUND High quality cardiopulmonary resuscitation (CPR) is one of the key elements of the survival chain in cardiac arrest. Audiovisual feedback of chest compressions have been suggested to be beneficial by increasing the quality of CPR in the simulated cardiac arrests. METHODS A prospective before and after study was performed to investigate the effect of a real-time audiovisual feedback system on CPR quality during in-hospital cardiac arrest in intensive care units from November 2018 to February 2022. In the feedback period, CPR was performed with the aid of the real-time audiovisual feedback system. The primary outcome was the percentage of compressions with both adequate depth (5.0-6.0 cm) and rate (100-120/minute). RESULTS A total of 27,295 compressions in 30 cardiac arrests in the no-feedback period and 27,965 compressions in 30 arrests in the feedback period were analyzed. The percentage of compressions with both adequate depth and rate was 11.8% in the feedback period and 16.8% in the no-feedback period (P < 0.01). The percentage of compressions with adequate rate in the feedback period was lower than that in the no-feedback period (67.3% vs. 75.5%, P < 0.01). The percentage of beyond-target depth with the feedback was significantly higher than that without feedback (64.2% vs. 51.4%, P < 0.01). CONCLUSION Real-time audiovisual feedback system did not increase CPR quality and was associated with a higher percentage of compression depth deeper than the recommended 5.0-6.0 cm. It is essential to explore more effective ways of implementing feedback in real clinical settings to improve of the quality of CPR. TRIAL REGISTRATION NCT03902873 (study start: Nov. 2018, initial release April 2019, retrospectively registered).
Collapse
Affiliation(s)
- Hannah Lee
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Daehak-Ro 101, Jongno-Gu, Seoul, 03080, Republic of Korea
| | - Jay Kim
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Somin Joo
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Daehak-Ro 101, Jongno-Gu, Seoul, 03080, Republic of Korea
| | - Sang-Hoon Na
- Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Sangmin Lee
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Sang-Bae Ko
- Department of Neurology, Seoul National University Hospital, Seoul, Korea
| | - Jinwoo Lee
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea
| | - Seung-Young Oh
- Department of Surgery, Seoul National University Hospital, Seoul, Korea
| | - Eun Jin Ha
- Department of Neurosurgery, Seoul National University Hospital, Seoul, Korea
| | - Ho Geol Ryu
- Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Daehak-Ro 101, Jongno-Gu, Seoul, 03080, Republic of Korea.
| |
Collapse
|
2
|
Wu C, You J, Liu S, Ying L, Gao Y, Li Y, Lu X, Qian A, Zhang M, Zhou G. Effect of a feedback system on the quality of 2-minute chest compression-only cardiopulmonary resuscitation: a randomised crossover simulation study. J Int Med Res 2019; 48:300060519894440. [PMID: 31884870 PMCID: PMC7607526 DOI: 10.1177/0300060519894440] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVE We evaluated the quality of 2-minute continuous chest compressions (CCCs) performed by emergency staff in 30-second intervals to determine the effect of a feedback system on maintaining the quality of CCCs. METHODS Two hundred three physicians and nurses were randomised into two groups. Each participant performed 2-minute CCCs both with and without feedback. Group A performed CCCs under the guidance of a feedback device followed by performance without feedback, and Group B performed these tasks in reverse order. The primary outcome was the proportion of optimal compressions; i.e., compressions at both the correct rate (100-120 beats/minute) and correct depth (5-6 cm). RESULTS During 2-minute CCCs, the proportion of optimal compressions was poor in personnel without feedback. The proportion of optimal compressions was unchanged and low from 2.4% (interquartile range, 0.0%-32.8%) in the first 30 seconds to 3.3% (0.0%-47.7%) in the last 30 seconds of the 2-minute period. Use of the feedback device significantly improved and maintained the quality of compressions from the first 30 seconds (53.3%; 29.2%-70.4%) to the last 30 seconds (82.8%; 50.8%-96.2%). CONCLUSION Use of the feedback device was helpful for maintaining the quality of CCCs.
Collapse
Affiliation(s)
- Chunshuang Wu
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Jingyu You
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Shaoyun Liu
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Lan Ying
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Yuzhi Gao
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Yulin Li
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Xiao Lu
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Anyu Qian
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Mao Zhang
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| | - Guangju Zhou
- Department of Emergency Medicine, Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|
3
|
Wattenbarger S, Silver A, Hoyne T, Kuntsal K, Davis D. Real-Time Cardiopulmonary Resuscitation Feedback and Targeted Training Improve Chest Compression Performance in a Cohort of International Healthcare Providers. J Emerg Med 2019; 58:93-99. [PMID: 31708314 DOI: 10.1016/j.jemermed.2019.09.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 09/13/2019] [Accepted: 09/20/2019] [Indexed: 11/27/2022]
Abstract
BACKGROUND Optimal cardiopulmonary resuscitation (CPR) performance is the foundation of successful cardiac arrest resuscitation. However, health care providers perform inadequate compressions. Better training techniques and real-time CPR feedback may improve compression performance. OBJECTIVE We sought to evaluate the impact of a targeted training program combined with real-time defibrillator CPR feedback on chest compression performance in an international cohort of health care providers. METHODS Physicians, nurses, respiratory therapists, and technicians from 6 hospitals in 5 countries (Taiwan, Singapore, China, Bahrain, and Kuwait) participated in a standardized resuscitation workshop. Chest compression was measured before and after didactics and activation of CPR feedback. Compressions were performed for 1 min on standard CPR manikins placed on a hospital bed and backboard and measured using ZOLL R Series defibrillators. The percentage of compressions meeting target values for depth and rate were compared before and after the workshop and activation of real-time CPR feedback. No depth maximum was defined to allow for mattress compression. RESULTS Chest compressions were more likely to meet targets for depth (71-95%, odds ratio [OR] 8.61 [95% confidence interval {CI} 4.42-16.77], p < 0.001), rate (41-81%, OR 6.4 [95% CI 4.2-9.8], p < 0.001), and both depth and rate (5-42%, OR 2.4 [95% CI 6.7-22.9], p < 0.001) after the workshop and activation of real-time CPR feedback. CONCLUSIONS A targeted training intervention combined with real-time CPR feedback improved chest compression performance among health care providers from various countries.
Collapse
Affiliation(s)
- Sara Wattenbarger
- Department of Emergency Medicine, Arrowhead Regional Medical Center, San Bernardino, California
| | | | - Tifany Hoyne
- Department of Emergency Medicine, Arrowhead Regional Medical Center, San Bernardino, California
| | | | - Daniel Davis
- Department of Emergency Medicine, Arrowhead Regional Medical Center, San Bernardino, California; Air Methods Corporation, Englewood, Colorado
| |
Collapse
|
4
|
The impact of real-time chest compression feedback increases with application of the 2015 guidelines. J Crit Care 2019; 54:145-150. [PMID: 31446232 DOI: 10.1016/j.jcrc.2019.06.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Revised: 06/19/2019] [Accepted: 06/28/2019] [Indexed: 11/22/2022]
Abstract
BACKGROUND Cardiac arrest survival depends upon chest compression quality. Real-time audiovisual feedback may improve compression guideline adherence, particularly with the more specific 2015 guidelines. METHODS Subjects included healthcare providers from multiple U.S. hospitals. Compression rate and depth were recorded using standard manikins and real-time audiovisual feedback defibrillators (ZOLL R Series). Subjects were enrolled before (n = 756) and after (n = 995) release of the 2015 guidelines, which define narrower compression targets. Subjects performed 2 min of continuous compressions before and after activation of feedback. The percentage of compressions meeting appropriate rate/depth targets was determined before and after release of the 2015 guidelines. RESULTS An increase in compression guideline adherence was observed with use of feedback before [68.7% to 96.3%, p < .001] and after [16.6% to 94.1%, p < .001] release of the 2015 guidelines. The proportion of subjects requiring feedback to achieve adherence was higher for the 2015 guidelines [28.6% vs. 78.5%, OR 9.12, 95% CI 7.33-11.35, p < .001]. CONCLUSIONS The use of real-time audiovisual feedback increases adherence to chest compression guidelines, particularly with application of the narrower 2015 guidelines targets for compression depth and rate.
Collapse
|
5
|
White AE, Ng HX, Ng WY, Ng EKX, Fook-Chong S, Kua PHJ, Ong MEH. Measuring the effectiveness of a novel CPRcard™ feedback device during simulated chest compressions by non-healthcare workers. Singapore Med J 2018; 58:438-445. [PMID: 28741006 DOI: 10.11622/smedj.2017072] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
INTRODUCTION There is a need for a simple-to-use and easy-to-carry CPR feedback device for laypersons. We aimed to determine if a novel CPRcard™ feedback device improved the quality of chest compressions. METHODS We compared participants' chest compression rate and depth with and without feedback. Compression data was captured through the CPRcard™ or Resusci Anne's SimPad® SkillReporter™. Compression quality was defined based on 2010 international guidelines for rate, depth and flow fraction. RESULTS Overall, the CPRcard group achieved a better median compression rate (CPRcard 117 vs. control 122, p = 0.001) and proportion of compressions within the adequate rate range (CPRcard 83% vs. control 47%, p < 0.001). Compared to the no-card and blinded-card groups, the CPRcard group had a higher proportion of adequate compression rate (CPRcard 88% vs. no-card 46.8%, p = 0.037; CPRcard 73% vs. blinded-card 43%, p = 0.003). Proportion of compressions with adequate depth was similar in all groups (CPRcard 52% vs. control 48%, p = 0.957). The CPRcard group more often met targets for compression rate of 100-120/min and depth of at least 5 cm (CPRcard 36% vs. control 4%, p = 0.022). Chest compression flow fraction rate was similar but not statistically significant in all groups (92%, p = 1.0). Respondents using the CPRcard expressed higher confidence (mean 2.7 ± 2.4; 1 = very confident, 10 = not confident). CONCLUSION Use of the CPRcard by non-healthcare workers in simulated resuscitation improved the quality of chest compressions, thus boosting user confidence in performing compressions.
Collapse
Affiliation(s)
- Alexander E White
- Unit for Prehospital Emergency Care, Singapore General Hospital, Singapore
| | - Han Xian Ng
- Barts and the London School of Medicine and Dentistry, United Kingdom
| | - Wai Yee Ng
- Health Services Research, Division of Research, Singapore General Hospital, Singapore
| | - Eileen Kai Xin Ng
- Unit for Prehospital Emergency Care, Singapore General Hospital, Singapore
| | - Stephanie Fook-Chong
- Health Services Research, Division of Research, Singapore General Hospital, Singapore.,Centre for Quantitative Medicine, Duke-NUS Medical School, Singapore
| | - Phek Hui Jade Kua
- Department of Emergency Medicine, KK Women's and Children's Hospital, Singapore
| | - Marcus Eng Hock Ong
- Department of Emergency Medicine, Singapore General Hospital, Singapore.,Health Services and Systems Research, Duke-NUS Medical School, Singapore
| |
Collapse
|
6
|
González-Calvete L, Barcala-Furelos R, Moure-González JD, Abelairas-Gómez C, Rodríguez-Núñez A. Utility of a simple lighting device to improve chest compressions learning. ACTA ACUST UNITED AC 2017; 64:506-512. [PMID: 28400132 DOI: 10.1016/j.redar.2017.02.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2016] [Revised: 02/24/2017] [Accepted: 02/27/2017] [Indexed: 01/20/2023]
Abstract
INTRODUCTION The recommendations on cardiopulmonary resuscitation (CPR) emphasize the quality of the manoeuvres, especially chest compressions (CC). Audiovisual feedback devices could improve the quality of the CC during CPR. The aim of this study was to evaluate the usefulness of a simple lighting device as a visual aid during CPR on a mannequin. MATERIAL AND METHODS Twenty-two paediatricians who attended an accredited paediatric CPR course performed, in random order, 2min of CPR on a mannequin without and with the help of a simple lighting device, which flashes at a frequency of 100 cycles per minute. The following CC variables were analyzed using a validated compression quality meter (CPRmeter®): depth, decompression, rate, CPR time and percentage of compressions. RESULTS With the lighting device, participants increased average quality (60.23±54.50 vs. 79.24±9.80%; P=.005), percentage in target depth (48.86±42.67 vs. 72.95±20.25%; P=.036) and rate (35.82±37.54 vs. 67.09±31.95%; P=.024). CONCLUSIONS A simple light device that flashes at the recommended frequency improves the quality of CC performed by paediatric residents on a mannequin. The usefulness of this CPR aid system should be assessed in real patients.
Collapse
Affiliation(s)
- L González-Calvete
- Servicio de Urgencias de Pediatría, Hospital de Cabueñes, Gijón, Asturias, España.
| | - R Barcala-Furelos
- Grupo de Investigación CLINURSID, Departamento de Enfermería, Universidad de Santiago de Compostela, Santiago de Compostela, La Coruña, España; Grupo de Investigación REMOSS, Facultad de Educación Física y Ciencias del Deporte, Universidad de Vigo, Pontevedra, España
| | - J D Moure-González
- Área de Pediatría. Hospital Clínico Universitario de Santiago de Compostela, Santiago de Compostela, La Coruña, España
| | - C Abelairas-Gómez
- Grupo de Investigación CLINURSID, Departamento de Enfermería, Universidad de Santiago de Compostela, Santiago de Compostela, La Coruña, España; Facultad de Ciencias de la Salud, Universidad Europea del Atlántico, Santander, España
| | - A Rodríguez-Núñez
- Servicio de Críticos y Urgencias Pediátricas, Hospital Clínico Universitario de Santiago de Compostela, La Coruña, España; Instituto de Investigación de Santiago (IDIS), Santiago de Compostela, La Coruña, España; Red SAMID II, Instituto Carlos III, Madrid, España
| |
Collapse
|
7
|
Greif R, Lockey A, Conaghan P, Lippert A, De Vries W, Monsieurs K. Ausbildung und Implementierung der Reanimation. Notf Rett Med 2015. [DOI: 10.1007/s10049-015-0092-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
8
|
|
9
|
Greif R, Lockey AS, Conaghan P, Lippert A, De Vries W, Monsieurs KG, Ballance JH, Barelli A, Biarent D, Bossaert L, Castrén M, Handley AJ, Lott C, Maconochie I, Nolan JP, Perkins G, Raffay V, Ringsted C, Soar J, Schlieber J, Van de Voorde P, Wyllie J, Zideman D. European Resuscitation Council Guidelines for Resuscitation 2015. Resuscitation 2015; 95:288-301. [DOI: 10.1016/j.resuscitation.2015.07.032] [Citation(s) in RCA: 272] [Impact Index Per Article: 30.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
10
|
Performance of chest compressions with the use of a new audio-visual feedback device: a randomized manikin study in health care professionals. Resuscitation 2014; 87:81-5. [PMID: 25449342 DOI: 10.1016/j.resuscitation.2014.10.004] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2014] [Revised: 09/03/2014] [Accepted: 10/01/2014] [Indexed: 11/23/2022]
Abstract
AIM Optimal depth (50-60mm) and rate (100-120min(-1)) of chest compressions (CC) is the prerequisite of effective cardiopulmonary resuscitation (CPR). However, insufficient CC during CPR are common even among health care professionals. We sought to evaluate if CC are more effective with the use of a novel feedback device compared to standard CC. Primary endpoints were absolute percentage of correct CC of all CC (correct rate and correct depth, classified as "optimal" CC), and the percentage of CC in target rate and percentage of CC in target depth. METHODS 63 healthcare professionals performed CC on a manikin with the use of a novel feedback device. The device provides audio-visual information about compression depth and rate. Each participant performed two minutes of CC with and without feedback. Participants were randomized into two groups that performed either CC with feedback first, followed by a trial without feedback, or vice versa. All participants answered a short questionnaire on self-estimation of CC performance. RESULTS The absolute percentage of optimal compressions of all compressions has increased from 27.9±28.8% to 47.6±33.5% (p<0.001) with use of the device. Furthermore, a significant increase of the percentage of CC in target depth (35.9±30.6% without vs. 54.8±33.5% with the device, p=0.003) and in target rate (70.5±37.7% without vs. 82.7±27.8 with the device, p=0.039) were observed. CONCLUSION This novel feedback device significantly improved the quality of CC in health care professionals.
Collapse
|
11
|
Kirkbright S, Finn J, Tohira H, Bremner A, Jacobs I, Celenza A. Audiovisual feedback device use by health care professionals during CPR: A systematic review and meta-analysis of randomised and non-randomised trials. Resuscitation 2014; 85:460-71. [DOI: 10.1016/j.resuscitation.2013.12.012] [Citation(s) in RCA: 122] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2013] [Revised: 10/30/2013] [Accepted: 12/09/2013] [Indexed: 11/28/2022]
|
12
|
Buléon C, Parienti JJ, Halbout L, Arrot X, De Facq Régent H, Chelarescu D, Fellahi JL, Gérard JL, Hanouz JL. Improvement in chest compression quality using a feedback device (CPRmeter): a simulation randomized crossover study. Am J Emerg Med 2013; 31:1457-61. [DOI: 10.1016/j.ajem.2013.07.029] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2013] [Revised: 07/26/2013] [Accepted: 07/28/2013] [Indexed: 11/25/2022] Open
|