1
|
Sappey-Marinier E, Beel W, Bonnin MP, Aït-Si-Selmi T. Better operating room efficiency and reduced staff demand: Individualised versus off-the-shelf total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2024. [PMID: 38864156 DOI: 10.1002/ksa.12233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 04/24/2024] [Accepted: 04/27/2024] [Indexed: 06/13/2024]
Abstract
PURPOSE The purpose of this pilot cross-sectional study was to compare the operating room (OR) efficiency and intraoperative staff task load when performing individualised versus off-the-shelf (OTS) total knee arthroplasty (TKA). METHODS A consecutive series of 28 patients randomised (1:1) to receive either OTS TKA or individualised TKA were included. The OR staff workload was assessed with the NASA Task Load Index (TLX), a subjective grading system assessing mental demand, physical demand, temporal demand, performance, effort and frustration on a scale from 0 (very low) to 20 (very high). The time for patient preparation, surgical time, closure and total OR time was recorded to assess OR efficiency. Effect sizes of differences between OTS and individualised TKA were expressed as mean differences (MDs) with 95% confidence intervals (CIs). RESULTS Patients in both cohorts were similar in age (OTS vs. individualised TKA (median [IQR]), 67 [63-76] vs. 71 [68-79]; p = 0.207) and body mass index (BMI) (29 [24-33] vs. 29 [26-31]; p = 0.807), and there were no significant differences in other preoperative characteristics. The OR staff perceived individualised TKA as less demanding than OTS TKA: Individualised TKA was rated significantly better across the six domains of the NASA TLX: mental demand by 5.6 points, physical demand by 6.3 points, temporal demand by 5.3 points, performance by 3.6 points, effort by 5.9 points and frustration by 5.8 points. Individualised TKA resulted in statistically significantly shorter mean total OR time (MD, 10 min; p = 0.018). CONCLUSION The staff in the OR found that individualised TKA is less mentally, physically and temporally demanding than OTS TKA. The average total time spent in the OR during individualised TKA is 10 min less than during OTS TKA. CLINICAL TRIAL REGISTRATION This study constitutes a part of a larger registered randomised controlled trial comparing patient satisfaction following OTS versus individualised TKA (NCT04460989). LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
| | - Wouter Beel
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Michel P Bonnin
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Tarik Aït-Si-Selmi
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| |
Collapse
|
2
|
Saeed AZ, Khaleeq T, Ahmed U, Ajula R, Boutefnouchet T, D'Alessandro P, Malik SS. No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2024; 144:1311-1330. [PMID: 37979098 DOI: 10.1007/s00402-023-05090-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 09/25/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) can be performed with either conventional off-the-shelf (OTS) or customized individually-made (CIM) implants. The evidence for CIM implants is limited and variable, and the aim of this review was to compare clinical and radiological outcomes between CIM and OTS implants. METHODS A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on clinical, radiological, or alignment outcomes for CIM and OTS implants were selected. The studies were appraised using the Methodical index for non-randomized studies tool. RESULTS Twenty-three studies fulfilled the inclusion criteria. The studies comprised 2856 CIM and 1877 OTS TKAs. Revision rate was higher with CIM (5.9%) compared to OTS (3.7%) implants [OR 1.23(95% CI 0.69-2.18)]. Manipulation under anesthesia (MUA) was higher in CIM (2.2%) compared to OTS (1.1%) group [OR 2.95(95% CI 0.95-9.13)] and complications rate was higher in CIM (5%) vs. OTS (4.5%) [OR 1.45(95% CI 0.53-3.96)] but neither reached statistical significance. Length of stay was significantly shorter in CIM group 2.9 days vs. 3.5 days [MD - 0.51(95% CI - 0.82 to - 0.20)]. Knee Society Score showed no difference between CIM and OTS groups for Knee 90.5 vs. 90.6 [MD - 0.27(95% CI - 4.27 to 3.73)] and Function 86.1 vs. 83.1 [MD 1.51(95% CI - 3.69 to 6.70)]. CONCLUSION CIM implants in TKA have theoretical benefits over OTS prostheses. However, in this present review, CIM implants were associated with higher revisions, MUA, and overall complication rates. There was no difference in outcome score and CIM implants did not improve overall target alignment; however, more CIM TKAs were found to be in the HKA target zone compared to OTS TKAs. The findings of this review do not support the general utilization of CIM over OTS implants in TKA.
Collapse
Affiliation(s)
- Abu Z Saeed
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK.
| | - Tahir Khaleeq
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK
| | - Usman Ahmed
- Worcestershire Acute Hospitals NHS Trust, Worcester, UK
| | - Randeep Ajula
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | - Peter D'Alessandro
- Orthopaedic Research Foundation of Western Australia, Medical School, Discipline of Surgery, University of Western Australia, Perth, Australia
| | | |
Collapse
|
3
|
Vogel N, Kaelin R, Rychen T, Wendelspiess S, Müller-Gerbl M, Arnold MP. Satisfaction after total knee arthroplasty: a prospective matched-pair analysis of patients with customised individually made and off-the-shelf implants. Knee Surg Sports Traumatol Arthrosc 2023; 31:5873-5884. [PMID: 37982843 PMCID: PMC10719143 DOI: 10.1007/s00167-023-07643-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Accepted: 10/17/2023] [Indexed: 11/21/2023]
Abstract
PURPOSE Customised individually made (CIM) total knee arthroplasty (TKA) was introduced to potentially improve patient satisfaction and other patient-reported outcome measures (PROMs). The purpose of this study was to compare PROMs, especially patient satisfaction, of patients with CIM and OTS TKA in a matched-pair analysis with a 2-year follow-up. METHODS This is a prospective cohort study with a propensity score matching of 85 CIM and 85 off-the-shelf (OTS) TKA. Follow-up was at 4 months, 1 year and 2 years. The primary outcome was patient satisfaction. Secondary outcomes were as follows: overall improvement, willingness to undergo the surgery again, Knee injury and Osteoarthritis Outcome Score (KOOS), Forgotten Joint Score (FJS-12), High-Activity Arthroplasty Score (HAAS), EQ-5D-3L, EQ-VAS, Knee Society Score (KSS) and surgeon satisfaction. RESULTS Patient satisfaction ranged from 86 to 90% and did not differ between CIM and OTS TKA. The EQ-VAS after 4 months and the HAAS after 1 year and 2 years were higher for CIM TKA. KOOS, FJS-12 and EQ-5D-3L were not different at follow-up. The changes in KOOS symptoms, pain and daily living were higher for OTS TKA. The KSS was higher for patients with CIM TKA. Surgeon satisfaction was high throughout both groups. Patients who were satisfied after 2 years did not differ preoperatively from those who were not satisfied. Postoperatively, all PROMs were better for satisfied patients. Patient satisfaction was not correlated with patient characteristics, implant or preoperative PROMs, and medium to strongly correlated with postoperative PROMs. CONCLUSION Patient satisfaction was high with no differences between patients with CIM and OTS TKA. Both implant systems improved function, pain and health-related quality of life. Patients with CIM TKA showed superior results in demanding activities as measured by the HAAS. LEVEL OF EVIDENCE II, prospective cohort study.
Collapse
Affiliation(s)
- Nicole Vogel
- Practice MEIN KNIE, Hirslanden Klinik Birshof, Reinacherstrasse 42, 4142, Münchenstein, Switzerland.
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland.
- Faculty of Medicine, University of Basel, Basel, Switzerland.
| | - Raphael Kaelin
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Thomas Rychen
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | - Séverin Wendelspiess
- Practice LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | | | - Markus P Arnold
- Practice MEIN KNIE, Hirslanden Klinik Birshof, Reinacherstrasse 42, 4142, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|
4
|
Liu Z, Zhou A, Fauveau V, Lee J, Marcadis P, Fayad ZA, Chan JJ, Gladstone J, Mei X, Huang M. Deep Learning for Automated Measurement of Patellofemoral Anatomic Landmarks. Bioengineering (Basel) 2023; 10:815. [PMID: 37508842 PMCID: PMC10376187 DOI: 10.3390/bioengineering10070815] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 06/30/2023] [Accepted: 07/02/2023] [Indexed: 07/30/2023] Open
Abstract
BACKGROUND Patellofemoral anatomy has not been well characterized. Applying deep learning to automatically measure knee anatomy can provide a better understanding of anatomy, which can be a key factor in improving outcomes. METHODS 483 total patients with knee CT imaging (April 2017-May 2022) from 6 centers were selected from a cohort scheduled for knee arthroplasty and a cohort with healthy knee anatomy. A total of 7 patellofemoral landmarks were annotated on 14,652 images and approved by a senior musculoskeletal radiologist. A two-stage deep learning model was trained to predict landmark coordinates using a modified ResNet50 architecture initialized with self-supervised learning pretrained weights on RadImageNet. Landmark predictions were evaluated with mean absolute error, and derived patellofemoral measurements were analyzed with Bland-Altman plots. Statistical significance of measurements was assessed by paired t-tests. RESULTS Mean absolute error between predicted and ground truth landmark coordinates was 0.20/0.26 cm in the healthy/arthroplasty cohort. Four knee parameters were calculated, including transepicondylar axis length, transepicondylar-posterior femur axis angle, trochlear medial asymmetry, and sulcus angle. There were no statistically significant parameter differences (p > 0.05) between predicted and ground truth measurements in both cohorts, except for the healthy cohort sulcus angle. CONCLUSION Our model accurately identifies key trochlear landmarks with ~0.20-0.26 cm accuracy and produces human-comparable measurements on both healthy and pathological knees. This work represents the first deep learning regression model for automated patellofemoral annotation trained on both physiologic and pathologic CT imaging at this scale. This novel model can enhance our ability to analyze the anatomy of the patellofemoral compartment at scale.
Collapse
Affiliation(s)
- Zelong Liu
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Alexander Zhou
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Valentin Fauveau
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Justine Lee
- Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Philip Marcadis
- Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Zahi A. Fayad
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
- Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Jimmy J. Chan
- Department of Orthopedics and Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - James Gladstone
- Department of Orthopedics and Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Xueyan Mei
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| | - Mingqian Huang
- Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
| |
Collapse
|
5
|
Bernard-de Villeneuve F, Bizzozero P, Fabre-Aubrespy M, Ollivier M, Argenson JN. Does Matching Femoral Size and Shape Improve Bone Fit and Patient-reported Outcomes in TKA? A Matched Controlled Study. Clin Orthop Relat Res 2023; 481:1129-1139. [PMID: 36716085 PMCID: PMC10194518 DOI: 10.1097/corr.0000000000002530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 11/23/2022] [Indexed: 01/31/2023]
Abstract
BACKGROUND Some researchers have suggested that achieving good component coverage over the host bone during TKA (while avoiding implant overhang) may help achieve durable implant fixation and may be associated with better outcomes scores. However, the evidence about this is limited and contradictory. Contemporary morphometric TKA includes a wide array of components with various shapes and sizes, based on large anatomic databases and specific software that simulates bone cuts. Morphometric tibial components have shown improved bone coverage and better clinical outcomes than standardized implants, but the role of morphometric femoral components in bone coverage has not been studied precisely. QUESTIONS/PURPOSES In a retrospective, controlled study that used patient matching, we asked: (1) Does the use of a contemporary morphometric component with more available sizes provide better femoral component fit and bone coverage than an earlier design with fewer sizes? (2) Are component fit and the presence of component overhang or underhang associated with different Knee Society Score (KSS) or Knee Injury and Osteoarthritis Outcome Score (KOOS) for Joint Replacement? METHODS From 2012 to 2013, we performed 403 TKAs according to the following criteria: TKA performed for primary tricompartmental arthritis of the knee; varus, valgus, and flexion deformity less than 15°; and age between 18 and 85 years on the day of surgery. Among these 403 TKAs, 237 were performed using a morphometric implant and 166 with the earlier nonmorphometric implant. At 2 years of follow-up, 3% of patients in the morphometric group and 5% in the nonmorphometric group were lost to follow-up. Based on age, BMI, gender, and preoperative KSS and KOOS, two groups of 30 patients were matched in a 1:1 ratio from this longitudinally maintained database. Clinical outcomes were measured preoperatively and at a minimum follow-up of 2 years in both groups, using the KSS and KOOS. We evaluated postoperative CT images for each patient to analyze femoral implant rotation, bone coverage, and overhang and underhang status. RESULTS The overhang status was similar between the two groups (23% had an overhang component in the morphometric knee group and 27% had an overhang component in the nonmorphometric knee group), and overhang was most frequently found in the lateral distal zone and medial anterior chamfer. Better cortical bone coverage was found in the morphometric knee group, with a thinner bone margin between the component edge and cortical border (morphometric group: 3 mm versus nonmorphometric knee group: 5 mm; p = 0.01). In general, there were few between-group differences in terms of patient-reported outcomes; of the seven metrics we analyzed, only the KSS favored the morphometric knee implant by a margin larger than the minimum clinically important difference (KSS mean difference: 21 points for the morphometric knee group; p < 0.05). Overhang of the femoral component of > 2 mm was associated with poorer KOOS, but not KSS, whereas a thinner bone margin had a beneficial impact on pain and global clinical scores (KOOS and KSS: p < 0.05). CONCLUSION The use of a morphometric femoral component design showed slightly improved bone fit and pain score according to the KSS at midterm follow-up compared with earlier implants with fewer sizes. Overhang > 2 mm was associated with worse KOOS. The tendency toward better outcomes in morphometric implants warrants longer-term evaluation before any definite conclusions about the association between bone fit and clinical results can be drawn.Level of Evidence Level III, therapeutic study.
Collapse
Affiliation(s)
| | - Paul Bizzozero
- Institute for Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France
| | - Maxime Fabre-Aubrespy
- Institute for Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France
| | - Matthieu Ollivier
- Institute for Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France
| | - Jean-Noel Argenson
- Institute for Locomotion, Department of Orthopedics and Traumatology, St. Marguerite Hospital, Marseille, France
| |
Collapse
|
6
|
Heesterbeek PJC. CORR Insights®: Does Matching Femoral Size and Shape Improve Bone Fit and Patient-reported Outcomes in TKA? A Matched Controlled Study. Clin Orthop Relat Res 2023; 481:1140-1142. [PMID: 36821466 PMCID: PMC10194516 DOI: 10.1097/corr.0000000000002613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 02/03/2023] [Indexed: 02/24/2023]
|
7
|
Wang B, Zhang G, Pu R, Li Q, Wang Y. Clinical significance of distal femur morphology in a healthy Mongolian youth population. Sci Rep 2023; 13:8187. [PMID: 37210457 DOI: 10.1038/s41598-023-35463-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 05/18/2023] [Indexed: 05/22/2023] Open
Abstract
Morphological parameters of knee joint are related to race and nationality. At present, knee prosthesis come from white male population. Due to the mismatch between the prosthesis and other ethnic groups, the prosthesis life span is reduced, revision surgery and the patients' economic burden are increased. There is no data of the Mongolian ethnic group. In order to treat patients more accurately, we measured the Mongolian data of the femoral condyle. A total of 122 knee joints were scanned in 61 volunteers (21 males and 40 females) with an average age of 23.259 ± 1.395 years. The Mimics software was used to reconstruct the 3D image and measure the data of each line. The data were analyzed by statistical methods such as t test, and P < 0.05 was taken as the significant. 122 normal femoral condyle data were obtained. The mean transverse diameter of femoral condyle is 76.472 ± 5.952 mm, medial condyle is 29.259 ± 11.461 mm, and the sagittal diameter of the medial condyle was 56.758 ± 4.163 mm. The transverse diameter of the lateral femoral condyle is 29.388 ± 3.157 mm, the sagittal diameter of the lateral condyle is 58.937 ± 3.527 mm and the femoral plane rate is 1.264 ± 0.072. (1) There was no statistical significance in the left and right knee joint data (P > 0.05). (2) The different genders data of femoral condyle were statistically significant (P < 0.05). (3) Compared with other nationalities and races, the data of femoral condyle are different. (4) There are differences between femoral surface ratio and mainstream prosthesis data.
Collapse
Affiliation(s)
- Boyang Wang
- Musculoskeletal Tumor Center, Peking University People's Hospital, Beijing, China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, China
| | - Guoliang Zhang
- Department of Orthopedics, The Affiliated Hospital of Inner Mongolia Medical University, Tongdaobeilu No.1, Hohhot, 010050, Inner Mongolia Autonomous Region, China
| | - Ribusurong Pu
- Department of Orthopedics, The Affiliated Hospital of Inner Mongolia Medical University, Tongdaobeilu No.1, Hohhot, 010050, Inner Mongolia Autonomous Region, China
| | - Qiang Li
- Department of Orthopedics, The Affiliated Hospital of Inner Mongolia Medical University, Tongdaobeilu No.1, Hohhot, 010050, Inner Mongolia Autonomous Region, China
| | - Yuewen Wang
- Department of Orthopedics, The Affiliated Hospital of Inner Mongolia Medical University, Tongdaobeilu No.1, Hohhot, 010050, Inner Mongolia Autonomous Region, China.
| |
Collapse
|
8
|
Bonanzinga T, Gambaro FM, Iacono F, Marcacci M. Sub-optimal femoral fit in total knee arthroplasty, a systematic review of human femoral data vs off-the-shelf contemporary femoral components. J Exp Orthop 2023; 10:41. [PMID: 37036541 PMCID: PMC10086082 DOI: 10.1186/s40634-023-00607-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 03/31/2023] [Indexed: 04/11/2023] Open
Abstract
PURPOSE The purpose of the current study is to investigate the inadequacy of fit between the human distal femur and the knee implants offerings and describe the available strategies to overcome this issue. METHODS A systematic research of the literature was performed to identify studies reporting morphologic measures of the distal femur. Studies were excluded if they included unhealthy knees or the morphological analysis did not report the two key dimensions to identify the patient's unique anatomy: AP length and mediolateral (ML) width. Clinically relevant component overhang or underhang was considered when the metal-bone mismatch was > 3 mm as described in the literature. RESULTS Six studies with anthropometric analysis of 1395 distal femurs met the inclusion criteria. The analysis revealed that by employing the available sizes of four current "state-of-the-art" primary off-the shelf (OTS) femoral implants up to 13-41% would show underhang and 9-27% overhang clinically relevant and the introduction of narrower sizes did not reduce this percentage of underhang but improved the overhang rate of 10-15%. CONCLUSIONS Whenever an ML/AP mismatch in encountered in the operating room, adaptations are needed, and these bring about deleterious biomechanical and clinical complications. Therefore, this study highlights the need for implants design with multiple ML offerings per AP size, since they provide not only more sizes options but more femoral shapes to match the different ML sizes of the distal femur, compared to designs with single ML offerings for a given femoral AP dimension.
Collapse
Affiliation(s)
- Tommaso Bonanzinga
- IRCCS Istituto Clinico Humanitas, Via A. Manzoni 56, 20089, Rozzano, Milan, Italy
- Humanitas University, Via Rita Levi Montalcini 4, 20090, Pieve Emanuele, Milan, Italy
| | | | - Francesco Iacono
- IRCCS Istituto Clinico Humanitas, Via A. Manzoni 56, 20089, Rozzano, Milan, Italy
- Humanitas University, Via Rita Levi Montalcini 4, 20090, Pieve Emanuele, Milan, Italy
| | - Maurilio Marcacci
- IRCCS Istituto Clinico Humanitas, Via A. Manzoni 56, 20089, Rozzano, Milan, Italy
- Humanitas University, Via Rita Levi Montalcini 4, 20090, Pieve Emanuele, Milan, Italy
| |
Collapse
|
9
|
Personalisation and customisation in total knee arthroplasty: the paradox of custom knee implants. Knee Surg Sports Traumatol Arthrosc 2023; 31:1193-1195. [PMID: 36934205 DOI: 10.1007/s00167-023-07385-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/20/2023]
|
10
|
Physiological Femoral Condylar Morphology in Adult Knees-A MRI Study of 517 Patients. Diagnostics (Basel) 2023; 13:diagnostics13030350. [PMID: 36766455 PMCID: PMC9914053 DOI: 10.3390/diagnostics13030350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 01/16/2023] [Accepted: 01/16/2023] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND In the age of individualised arthroplasty, the question arises whether currently available standard implants adequately consider femoral condylar morphology (FCM). Therefore, physiological reference values of FCM are needed. The aim was to establish physiological reference values for anterior (ACO) and posterior condylar offset (PCO) as well as for the length of the medial (LMC) and lateral femoral condyles (LLC). METHODS The knee joints of 517 patients (mean age: 52.3 years (±16.8)) were analysed retrospectively using MRI images. Medial (med) and lateral (lat) ACO and PCO, as well as LMC and LLC, were measured. All FCM parameters were examined for association with age, gender, side and osteoarthritis. RESULTS Mean ACOmed was 2.8 mm (±2.5), mean ACOlat was 6.7 mm (±2.3), mean PCOmed was 25.7 mm (±4.6), mean PCOlat was 23.6 mm (±3.0), mean LMC was 63.7 mm (±5.0) and mean LLC was 64.4 mm (±5.0). Except for PCOmed, the mean values of all other FCM parameters were significantly higher in male knees compared to female knees. ACOmed and PCOmed showed significant side-specific differences. There were no significant differences in relation to age and osteoarthritis. CONCLUSION The study showed significant differences in FCM side- and gender-specifically in adult knees. These aspects should be considered in the discussion of individual and gender-specific knee joint replacement.
Collapse
|
11
|
Maeyama A, Asayama I, Ishimatsu T, Yamamoto T. Effect of the posterior sagging control device to the posterior tibial translation during posterior-stabilized total knee arthroplasty with modified gap technique. J Orthop Surg (Hong Kong) 2022; 30:10225536221144715. [PMID: 36516023 DOI: 10.1177/10225536221144715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
PURPOSE In modern total knee arthroplasty (TKA), flexion and extension gaps between the femur and tibia are equilibrated before implanting the final components. Uncontrolled intraoperative posterior tibial translation (PTT) could cause an artifactual widening of the flexion gap, which could lead surgeons to alter the femoral component size. We designed an intraoperative posterior sagging control device to prevent intraoperative PTT. In this study, we investigated whether the use of this device could prevent artifactual widening of the flexion gap. METHODS Twenty-five patients, 21 women and four men, aged 74.2 years, were enrolled in this prospective study. All patients underwent postero-stabilized TKA using a navigation system. Intraoperative PTT, flexion and extension gaps with or without using the posterior sagging control device were measured with navigation system. These measurements were compared with or without the posterior sagging control device and after the final implantation also. RESULTS There were significant differences between the measurements performed with or without the posterior sagging control device when compared to the post-implantation measurements. The use of the device reduced the number of patients with a >3 mm increase in flexion gap from 7 (28%) to 1 (4%). CONCLUSION This study suggests that the posterior sagging control device prevents PTT and artificial flexion gap widening. This could prevent an unnecessary increase in component size.
Collapse
Affiliation(s)
- Akira Maeyama
- Department of Orthopedic Surgery, Faculty of Medicine, 12774Fukuoka University, Fukuoka, Japan
| | - Isao Asayama
- Bone and Joint Research Center, Department of Orthopedic Surgery, Medical Corporation Keijinkai Kawasaki Hospital, Yame, Japan
| | - Tetsuro Ishimatsu
- Department of Orthopedic Surgery, Faculty of Medicine, 12774Fukuoka University, Fukuoka, Japan
| | - Takuaki Yamamoto
- Department of Orthopedic Surgery, Faculty of Medicine, 12774Fukuoka University, Fukuoka, Japan
| |
Collapse
|
12
|
Burge TA, Jones GG, Jordan CM, Jeffers JR, Myant CW. A computational tool for automatic selection of total knee replacement implant size using X-ray images. Front Bioeng Biotechnol 2022; 10:971096. [PMID: 36246387 PMCID: PMC9557045 DOI: 10.3389/fbioe.2022.971096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 08/24/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose: The aim of this study was to outline a fully automatic tool capable of reliably predicting the most suitable total knee replacement implant sizes for patients, using bi-planar X-ray images. By eliminating the need for manual templating or guiding software tools via the adoption of convolutional neural networks, time and resource requirements for pre-operative assessment and surgery could be reduced, the risk of human error minimized, and patients could see improved outcomes.Methods: The tool utilizes a machine learning-based 2D—3D pipeline to generate accurate predictions of subjects’ distal femur and proximal tibia bones from X-ray images. It then virtually fits different implant models and sizes to the 3D predictions, calculates the implant to bone root-mean-squared error and maximum over/under hang for each, and advises the best option for the patient. The tool was tested on 78, predominantly White subjects (45 female/33 male), using generic femur component and tibia plate designs scaled to sizes obtained for five commercially available products. The predictions were then compared to the ground truth best options, determined using subjects’ MRI data.Results: The tool achieved average femur component size prediction accuracies across the five implant models of 77.95% in terms of global fit (root-mean-squared error), and 71.79% for minimizing over/underhang. These increased to 99.74% and 99.49% with ±1 size permitted. For tibia plates, the average prediction accuracies were 80.51% and 72.82% respectively. These increased to 99.74% and 98.98% for ±1 size. Better prediction accuracies were obtained for implant models with fewer size options, however such models more frequently resulted in a poor fit.Conclusion: A fully automatic tool was developed and found to enable higher prediction accuracies than generally reported for manual templating techniques, as well as similar computational methods.
Collapse
Affiliation(s)
- Thomas A. Burge
- Dyson School of Design Engineering, Imperial College, London, United Kingdom
- *Correspondence: Thomas A. Burge,
| | | | | | | | - Connor W. Myant
- Dyson School of Design Engineering, Imperial College, London, United Kingdom
| |
Collapse
|
13
|
Custom TKA combined with personalised coronal alignment yield improvements that exceed KSS substantial clinical benefits. Knee Surg Sports Traumatol Arthrosc 2022; 30:2958-2965. [PMID: 35182169 DOI: 10.1007/s00167-022-06867-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 12/31/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE The purpose of this study was to report Knee Society Scores (KSS) at 12-month follow-up in a series of 266 knees that received custom TKA. The hypothesis was that custom TKA combined with personalised alignment would yield improvements greater than substantial clinical benefits (SCB) of KSS Knee and Function. METHODS From a consecutive series of 905 patients (918 knees) that received primary TKAs, 261 (29%) patients (266 knees) received computed tomography (CT)-based posterior-stabilised cemented custom TKA. Knees were aligned aiming to preserve or restore constitutional alignment within predetermined limits of 85°-95° for femoral mechanical angle (FMA) and tibial mechanical angle (TMA), and 175°-183° for hip knee ankle (HKA) angle. The KSS Knee and Function were collected preoperatively and 12 months postoperatively, to determine if patients achieved SCB. Uni- and multivariable analyses were performed to determine associations between KSS scores (Knee and Function) and patient demographics as well as pre- and postoperative radiographic alignments. RESULTS Of the initial cohort of 261 patients, 4 (1.8%) were reoperated for patellar resurfacing, 1 (0.4%) for lavage to treat infection, and 1 (0.4%) had arthroscopy to treat a stiff knee with < 90° range of motion. Complete clinical records were available for 227 patients (232 knees, 87%) that comprised 102 men (5 bilateral) and 125 women. At 12-month follow-up, mean improvements in KSS Knee and Function scores were, respectively, 61.0 ± 13.0 and 42.7 ± 16.7, which exceeded the SCB of KSS. Comparison of knees inside versus outside the target zone revealed no differences in KSS Knee (94.1 ± 9.1 versus 94.3 ± 9.0, n.s.) and Function (96.1 ± 9.2 versus 96.3 ± 8.9, n.s.). Multivariable analysis revealed worse KSS Knee in knees with preoperative FMA > 95° (β = - 6.21; p = 0.023), but no association between KSS Function and patient demographics or pre- and postoperative radiographic alignments. CONCLUSIONS Custom TKA combined with personalised alignment yielded improvements that exceeded substantial clinical benefits of KSS Knee and Function scores. These findings demonstrate the feasibility of custom TKA with 'personalised alignment' and encourage further investigations using comparative studies at longer follow-up. LEVEL OF EVIDENCE IV, case series.
Collapse
|
14
|
Kim J, Park S, Ahn JH. Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty. Arch Orthop Trauma Surg 2022; 142:2065-2074. [PMID: 34405258 DOI: 10.1007/s00402-021-04111-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 07/28/2021] [Indexed: 12/24/2022]
Abstract
BACKGROUND Recently, total knee arthroplasty (TKA) designs that allow the use of narrow-version femoral implants have been introduced to avoid femoral overhang. The purpose of this study was to investigate the frequency of the use of narrow-version femoral implants and identify the difference in radiographic parameters between using a narrow-version femoral implant and a standard-version femoral implant in TKA. METHODS A retrospective study was conducted on 504 primary TKAs using a TKA system (Anthem or Persona) that allowed narrow-version femoral implants. Anteroposterior (AP) dimension, mediolateral (ML) dimension, and modified aspect percentage ratio (ML/AP dimension) of the distal femur in preoperative radiographs were compared between a standard-version group (n = 275) and a narrow-version group (n = 229). A cut-off value of a modified aspect percentage ratio indicating the need for a narrow-version femoral implant was determined using the receiver operating characteristic (ROC) curve. RESULTS Mean ML dimension was 80.9 ± 6.1 mm in the standard-version group and 77.3 ± 4.4 mm in the narrow-version group (p < 0.001). Mean modified aspect percentage ratio was 138.8 ± 8.1% in the standard-version group and 131.7 ± 6.3% in the narrow-version group (p < 0.001). The optimum cut-off point of the modified aspect percentage ratio for narrow-version femoral implants was 135.4% (sensitivity: 72.0%; specificity: 66.7%) for Anthem and 133.3% (sensitivity: 75.9%, specificity: 76.4%) for Persona. CONCLUSION In the narrow-version femoral implant group, the ML dimension and the mean modified aspect percentage ratio were smaller than in the standard-version femoral implant group. A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. It was suggested that the cut-off point could be suggested as 135.4% for Anthem TKA design and 133.3% for Persona TKA design. These radiographic parameters are cost-effective and easily applicable for planning a TKA.A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. The cut-off point was 135.4% for Anthem TKA design and 133.3% for Persona TKA design.
Collapse
Affiliation(s)
- Jaehyun Kim
- Department of Orthopedic Surgery, International Baro Hospital, Incheon, Republic of Korea
| | - Seongyun Park
- Department of Orthopedic Surgery, Dongguk University Ilsan Hospital, Goyang, Gyeonggido, Republic of Korea
| | - Ji Hyun Ahn
- Department of Orthopedic Surgery, Kangbuk Samsung Hospital, School of Medicine, Sungkyunkwan University, 29, Saemunan-ro, Jongno-gu, Seoul, 03181, Republic of Korea.
| |
Collapse
|
15
|
Khalifa AA, Fayez M, Elkady H, Abdelaal AM, Elassal MA. The Outcome of Posterior-Stabilized, Rotating Platform Total Knee Arthroplasty at a Minimum Ten-Year Follow-Up, a Middle East Institution Experience. J Knee Surg 2022; 35:718-724. [PMID: 33126282 DOI: 10.1055/s-0040-1716850] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Posterior-stabilized, rotating platform knee prosthesis design was aimed to decrease polyethylene wear for the sake of improving implant survivorship. The purpose of the present prospective study was to evaluate the long-term clinical and radiographic results as well as the survival rate after using a rotating platform, posterior-stabilized knee prosthesis at a minimum of 10 years at a Middle East institution. We compared the results with reports in the literature on western populations. From January 2002 to June 2008, 96 patients (106 knees) underwent total knee arthroplasty (TKA) using a cemented rotating platform posterior-stabilized knee prosthesis. At a mean of 11.5 ± 1.3 years, 85 patients (95 TKAs) were available for clinical, radiographic, and implant survival analysis. At the final follow-up, 78.9% of the patients had excellent Knee Society Scoring system score, the average knee flexion was 110 ± 17 degrees, the average anatomical knee coronal alignment was 186 ± 2 degrees and 187 ± 3 degrees for varus and valgus knees, respectively. Five (5.2%) knees were revised of these: two for bearing dislocation, two for aseptic loosening, and one for infection. The Kaplan-Meier survival rate was 94.7% for all revisions and 97.8% when only revision for aseptic loosening considered as the end point. At a long-term follow-up, reasonable clinical and radiographic outcomes had been achieved after using a rotating platform, posterior-stabilized knee prosthesis in our population with acceptable survival rate reaching up to 95%, which is comparable to reports from the western population.
Collapse
Affiliation(s)
- Ahmed A Khalifa
- Department of Orthopaedics, Assiut University Hospital, Assiut, Egypt.,Department of Orthopaedics, Qena Faculty of Medicine and University Hospital, South Valley University, Qena, Egypt
| | - Mostafa Fayez
- Department of Orthopaedics, Student's Hospital, Assiut University, Assiut, Egypt
| | - Hesham Elkady
- Department of Orthopaedics, Assiut University Hospital, Assiut, Egypt
| | - Ahmed M Abdelaal
- Department of Orthopaedics, Assiut University Hospital, Assiut, Egypt
| | - Maher A Elassal
- Department of Orthopaedics, Assiut University Hospital, Assiut, Egypt
| |
Collapse
|
16
|
Burge TA, Jeffers JRT, Myant CW. A computational design of experiments based method for evaluation of off-the-shelf total knee replacement implants. Comput Methods Biomech Biomed Engin 2022; 26:629-638. [PMID: 35549770 DOI: 10.1080/10255842.2022.2075224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
A methodology to explore the design space of off-the-shelf total knee replacement implant designs is outlined. Generic femur component and tibia plate designs were scaled to thousands of sizes and virtually fitted to 244 test subjects. Various implant designs and sizing requirements between genders and ethnicities were evaluated. 5 sizes optimised via the methodology produced a good global fit for most subjects. However, clinically significant over/underhang was present in 19% of subjects for tibia plates and 25% for femur components, reducing to 11/20% with 8 sizes. The analysis highlighted subtly better fit performance was obtained using sizes with unequal spacing.
Collapse
Affiliation(s)
- Thomas A Burge
- Dyson School of Design Engineering, Imperial College, London, UK
| | | | - Connor W Myant
- Dyson School of Design Engineering, Imperial College, London, UK
| |
Collapse
|
17
|
Xu JZ, Li LL, Fu J, Xu C, Zhang GQ, Chai W, Hao LB, Li X, Chen JY. Comparison of serum inflammatory indicators and radiographic results in MAKO robotic-assisted versus conventional total knee arthroplasty for knee osteoarthritis: a retrospective study of Chinese patients. BMC Musculoskelet Disord 2022; 23:418. [PMID: 35509075 PMCID: PMC9066791 DOI: 10.1186/s12891-022-05373-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 04/27/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The purpose of this study was to compare the serum inflammatory indicators and radiographic results of conventional manual total knee arthroplasty (CM-TKA) with those of MAKO-robotic assisted total knee arthroplasty (MA-TKA). METHODS We retrospectively analysed 65 patients with knee osteoarthritis who underwent unilateral TKA from December 2020 to November 2021 in our department, which included 34 patients who underwent MA-TKA and 31 patients who underwent CM-TKA. The tourniquet time and estimated blood loss (EBL) were compared between the two groups. Knee function was evaluated using range of motion (ROM), functional score and pain score. Leukocytes, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), interleukin-6 (IL-6), creatine kinase (CK), and neutrophil-to-lymphocyte ratio (NLR) were recorded at 3 time points (preoperative, and on the first and third postoperative days). The hip-knee-ankle angle (HKA) and the femoral and tibial component angles in the coronal and sagittal planes were used for postoperative radiographic evaluation. RESULTS The postoperative MA-TKA group had less EBL (496.9 ± 257.8 vs. 773.0 ± 301.3 ml, p < 0.001). There was no significant difference in knee function scores at 6 weeks postoperatively (p > 0.05). IL-6 levels were significantly lower in the MA-TKA group on the 1st postoperative day (11.4 (5.2, 21.0) vs. 24.6 (86.3, 170.8), p = 0.031). This difference in inflammatory indices became more pronounced at 72 hours after the operation because CRP, ESR, IL-6, and CK values were significantly lower in the MA-TKA group on the 3rd postoperative day (72 h) (p < 0.05). Postoperative radiographic examinations performed 2 days after the MA-TKA group suggested that only 2 cases of HKA had outlier values, which was remarkably better than the 12 cases found in the CM-TKA group (5.9% vs. 38.7%, p < 0.001). The frontal femoral component was significantly closer to the expected value of 90° in the MA-TKA group (90.9 (90.5, 92.3) vs. 92.4 (91.3, 93.7), p = 0.031). The remaining imaging evaluation parameters were not significantly different between the two groups (p > 0.05). CONCLUSIONS In Chinese patients with OA, there was a milder systemic inflammatory response in the early postoperative period after MA-TKA compared to that of CM-TKA, as well as better radiographic outcomes. However, the tourniquet time was prolonged, and no advantages were observed in terms of functional score or pain score in the short-term follow-up.
Collapse
Affiliation(s)
- Jia-Zheng Xu
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China.,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China
| | - Liang-Liang Li
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China.,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.,Department of Orthopaedics, The Second Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Jun Fu
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China.,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China
| | - Chi Xu
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China.,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China
| | - Guo-Qiang Zhang
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China.,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China
| | - Wei Chai
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China.,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China
| | - Li-Bo Hao
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China.,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China.,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China
| | - Xiang Li
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China. .,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China. .,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China.
| | - Ji-Ying Chen
- Senior Department of Orthopaedics, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100142, China. .,Department of Orthopaedics, The First Medical Center, Chinese PLA General Hospital, No. 28 Fuxing Road, Haidian District, Beijing, 100853, China. .,National Clinical Research Center for Orthopaedics, Sports Medicine & Rehabilitation, Beijing, 100853, China.
| |
Collapse
|
18
|
Shen QH, Baik JW, Won YY. The Morphology of a Kinematically Aligned Distal Femoral Osteotomy Is Different from That Obtained with Mechanical Alignment and Could Have Implications for the Design of Total Knee Arthroplasty. J Pers Med 2022; 12:jpm12030422. [PMID: 35330422 PMCID: PMC8955119 DOI: 10.3390/jpm12030422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 02/24/2022] [Accepted: 03/04/2022] [Indexed: 01/25/2023] Open
Abstract
Background: Kinematically aligned total knee arthroplasty (KA-TKA) may lead to a different pattern of osteotomy from mechanically aligned total knee arthroplasty (MA-TKA). This paper aims to analyze the effects of KA and MA on the morphology of the distal femoral osteotomy surface. Methods: Computed tomography scans of 80 TKA candidates were reconstructed into 3D models. The measurement of bone morphology was performed after the distal femur cut according to two different alignment techniques. The aspect ratio, trapezoidicity ratio, and asymmetry ratio of the distal femur were assessed. Results: The aspect ratio and the asymmetry ratio in the KA group was significantly lower than that in the MA group in the general population (p < 0.001). The trapezoidicity ratio in the KA group was significantly higher than that in the MA group in the general population (p < 0.001). Conclusions: It was found that KA-TKA and MA-TKA presented different morphologies of the distal femoral osteotomy surface, and this difference was also influenced by gender. The surgery pattern of KA-TKA and MA-TKA and gender should be considered when surgeons choose femoral prostheses.
Collapse
Affiliation(s)
- Quan-Hu Shen
- Department of Orthopaedic Surgery, Ajou University College of Medicine, Ajou Medical Center, Suwon 16499, Korea; (Q.-H.S.); (J.-W.B.)
- Department of Orthopeadic Surgery, First People’s Hospital of Suqian City, Suqian 223800, China
| | - Ji-Woong Baik
- Department of Orthopaedic Surgery, Ajou University College of Medicine, Ajou Medical Center, Suwon 16499, Korea; (Q.-H.S.); (J.-W.B.)
| | - Ye-Yeon Won
- Department of Orthopaedic Surgery, Ajou University College of Medicine, Ajou Medical Center, Suwon 16499, Korea; (Q.-H.S.); (J.-W.B.)
- Correspondence: ; Tel.: +82-31-219-5223
| |
Collapse
|
19
|
Beckers L, Müller JH, Daxhelet J, Saffarini M, Aït-Si-Selmi T, Bonnin MP. Sexual dimorphism and racial diversity render bone-implant mismatch inevitable after off-the-shelf total knee arthroplasty: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2022; 30:809-821. [PMID: 33512544 DOI: 10.1007/s00167-021-06447-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 01/11/2021] [Indexed: 01/15/2023]
Abstract
PURPOSE The purpose of this systematic review and meta-analysis was to investigate the variability in femoral geometric ratios among knees of different sexes and races, and to appreciate whether the observed variability is accommodated by commonly implanted total knee arthroplasty (TKA) components. The hypothesis was that the anthropometric studies report considerable variability of femoral geometric ratios among sexes and races. METHODS This systematic review and meta-analysis was performed according to the Preferred Reporting Items for Systematic reviews and Meta-analyses (PRISMA) criteria. Two authors independently conducted an electronic search using MEDLINE® and Embase® on 6 July 2020 for clinical studies reporting on femoral geometric ratios among sexes and races. Femoral geometric ratios were graphically represented as means and 2 standard deviations, and compared to those of 13 commonly implanted femoral components. RESULTS A total of 15 studies were identified that reported on a combined total of 2627 knees; all reported the aspect ratio, and 2 also reported the asymmetry ratio and trapezoidicity ratio. Men had wider knees than women, and compared to Caucasian knees, Arabian and Indian knees were wider, while East Asian were narrower. There were no differences in asymmetry ratio between men and women, nor among Caucasian and East Asian knees. Men had more trapezoidal knees than women, and East Asian knees were more trapezoidal than Caucasian knees. The commonly implanted femoral components accommodated less than a quarter of the geometric variability observed among sexes and races. CONCLUSION Anthropometric studies reported considerable sexual dimorphism and racial diversity of femoral geometric ratios. Since a surgeon generally only uses one or a few TKA brands, bone-implant mismatch remains unavoidable in a large proportion of knees. These findings support the drive towards personalized medicine, and accurate bone-implant fit may only be achievable through customisation of implants, though the clinical benefits of custom TKA remain to be confirmed. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Lucas Beckers
- Ramsay Santé, Centre Orthopédique Santy, Hôpital Privé Jean Mermoz, Lyon, France
| | | | - Jeremy Daxhelet
- Ramsay Santé, Centre Orthopédique Santy, Hôpital Privé Jean Mermoz, Lyon, France
| | - Mo Saffarini
- ReSurg SA, Rue Saint-Jean 22, 1260, Nyon, Switzerland.
| | - Tarik Aït-Si-Selmi
- Ramsay Santé, Centre Orthopédique Santy, Hôpital Privé Jean Mermoz, Lyon, France
| | - Michel P Bonnin
- Ramsay Santé, Centre Orthopédique Santy, Hôpital Privé Jean Mermoz, Lyon, France
| |
Collapse
|
20
|
Wendelspiess S, Kaelin R, Vogel N, Rychen T, Arnold MP. No difference in patient-reported satisfaction after 12 months between customised individually made and off-the-shelf total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2022; 30:2948-2957. [PMID: 35149877 PMCID: PMC9418302 DOI: 10.1007/s00167-022-06900-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 01/16/2022] [Indexed: 11/27/2022]
Abstract
PURPOSE A subset of patients is usually not satisfied after a total knee arthroplasty (TKA). Customised individually made (CIM) TKA are deemed to overcome drawbacks of classical off-the-shelf (OTS) TKA, but evidence is still sparse. The aim of this study was to compare satisfaction of patients with CIM and OTS TKA. METHODS This prospective cohort study compared clinical and patient-reported outcome measures (PROM) between patients with CIM and OTS TKA. The primary outcome was patient satisfaction after 12 months. Secondary outcomes were the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), the Forgotten Joint Score (FJS-12) and the EQ-5D-3L after 4 and 12 months. RESULTS Data were analysed from 74 CIM TKA and 169 OTS TKA between January 2017 and September 2020. Patients with CIM TKA were slightly younger, more often male, had a lower body mass index, a lower KSS and partially higher preoperative PROMs. Patient satisfaction after 12 months was high and comparable (CIM 87%, OTS 89%). All PROMs improved for both groups (p < 0.001) and did not differ after 12 months (p > 0.063). The majority of patients improved above the minimal important difference (range 65 to 89%) and reported a clear overall improvement (CIM 86%, OTS 87%). The postoperative KSS, notably regarding knee stability, was higher for CIM TKA (p < 0.001). CONCLUSION No difference was found in patient satisfaction between CIM and OTS TKA after 12 months. In both groups, patient satisfaction was high and PROMs improved considerably. LEVEL OF EVIDENCE II, prospective cohort study.
Collapse
Affiliation(s)
- Séverin Wendelspiess
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | - Raphael Kaelin
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
| | - Nicole Vogel
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland.
- Faculty of Medicine, University of Basel, Basel, Switzerland.
| | - Thomas Rychen
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
| | - Markus P Arnold
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|
21
|
Lack of small tibial component size availability for females in a highly utilized total knee arthroplasty system. Knee Surg Sports Traumatol Arthrosc 2021; 29:3164-3169. [PMID: 32533222 DOI: 10.1007/s00167-020-06082-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 05/22/2020] [Indexed: 11/27/2022]
Abstract
PURPOSE Surgeons must rely on manufacturers to provide an appropriate distribution of total knee arthroplasty (TKA) sizes. There is a lack of literature regarding current appropriateness of tibial sizing schemes according to sex. As such, a study was devised assessing the adequacy of off-the-shelf tibial component size availability according to sex. METHODS A search was conducted to identify all primary TKAs between July 2012 and June 2019 performed using a single implant. Baseline patient characteristics were collected (age, weight, height, BMI, and race). Two cohorts were created according to patient sex. Tibial sizes for each cohort were collected. Tibial component bar graph and histogram were created according to component sizes. Skewness and kurtosis were calculated for each distribution. Overhang was noted and measured radiographically. RESULTS A total of 864 patients were identified, 38.7% males and 61.3% females. Most patients were Caucasian, and BMI was similar between cohorts. Tibial size distribution for males was as follows: 0.3% C, 4.8% D, 16.5% E, 40.1% F, 31.4% G, 6.9% H. Tibial size distribution for females was as follows: 30.8% C, 42.8% D, 23.0% E, 2.6% F, 0.8% G, 0.0% H. Histograms and normal curves demonstrated a fairly symmetric distribution of sizes for males (skewness = - 0.31, kurtosis = - 0.03). The distribution for females was positively skewed (skewness = 0.57, kurtosis = 0.12). Overall, overhang was noted in 16.6% of all size C tibias. CONCLUSIONS The results of this study highlight an implant-specific discrepancy in size availability affecting female patients which could result in inferior outcomes. The authors urge manufacturers to critically assess current implant size distribution availability to ensure both genders are adequately, and equally represented. LEVEL OF EVIDENCE IV.
Collapse
|
22
|
Yang CP, Lai YC, Wu CT, Hung KT, Chan YS, Chen ACY, Hsu KY. Using MRI Measurement to Improve Accuracy of Femoral Component Sizing in Oxford Unicompartmental Knee Arthroplasty. J Clin Med 2021; 10:4284. [PMID: 34575395 PMCID: PMC8469505 DOI: 10.3390/jcm10184284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 09/14/2021] [Accepted: 09/16/2021] [Indexed: 11/23/2022] Open
Abstract
Unicompartmental knee arthroplasty (UKA) can achieve better kinematics and faster recovery than total knee arthroplasty. The Phase III Oxford UKA system has five sizes of femoral components to approximate the normal knee geometry. However, these different sizes may also induce problems, such as the misselection of component size. Different criteria have been proposed to predict the ideal size preoperatively. However, no single method can be applied universally. Therefore, this study aimed to develop a preoperative measurement using knee magnetic resonance imaging (MRI) to predict femoral component size. A total of 68 patients who underwent UKA were investigated from June 2019 to April 2020. 16 knees using a different MRI protocol were excluded. We developed an MRI measurement method to determine femoral size instead of gender- and height-based methods. The accuracy of different methods was compared using postoperative true lateral view radiographs. Three different kinds of gender- and height-based criteria, preoperative templating and intraoperative spoon measurement were compared. The accuracy of MRI measurement was 90.3%. Therefore, a significant difference was found between MRI measurements and all other methods, such as templating or gender- and height-based methods. In conclusion, the MRI measurement method can be concluded to accurately predict femoral component size in UKA. This method could be used regardless of different ethnic groups, individual knee geometry, or soft tissue tension.
Collapse
Affiliation(s)
- Cheng-Pang Yang
- Department of Orthopedic Surgery, Division of Sports Medicine, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Linkou, Taoyuan 333, Taiwan; (C.-P.Y.); (K.-T.H.); (Y.-S.C.); (A.C.-Y.C.)
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou 333, Taiwan
- Comprehensive Sports Medicine Center, Linkou Chang Gung Memorial Hospital, Linkou 333, Taiwan
| | - Ying-Chieh Lai
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan 333, Taiwan; (Y.-C.L.); (C.-T.W.)
| | - Chen-Te Wu
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan 333, Taiwan; (Y.-C.L.); (C.-T.W.)
| | - Kung-Tseng Hung
- Department of Orthopedic Surgery, Division of Sports Medicine, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Linkou, Taoyuan 333, Taiwan; (C.-P.Y.); (K.-T.H.); (Y.-S.C.); (A.C.-Y.C.)
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou 333, Taiwan
| | - Yi-Sheng Chan
- Department of Orthopedic Surgery, Division of Sports Medicine, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Linkou, Taoyuan 333, Taiwan; (C.-P.Y.); (K.-T.H.); (Y.-S.C.); (A.C.-Y.C.)
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou 333, Taiwan
- Comprehensive Sports Medicine Center, Linkou Chang Gung Memorial Hospital, Linkou 333, Taiwan
| | - Alvin Chao-Yu Chen
- Department of Orthopedic Surgery, Division of Sports Medicine, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Linkou, Taoyuan 333, Taiwan; (C.-P.Y.); (K.-T.H.); (Y.-S.C.); (A.C.-Y.C.)
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou 333, Taiwan
- Comprehensive Sports Medicine Center, Linkou Chang Gung Memorial Hospital, Linkou 333, Taiwan
| | - Kuo-Yao Hsu
- Department of Orthopedic Surgery, Division of Sports Medicine, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Linkou, Taoyuan 333, Taiwan; (C.-P.Y.); (K.-T.H.); (Y.-S.C.); (A.C.-Y.C.)
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou 333, Taiwan
- Comprehensive Sports Medicine Center, Linkou Chang Gung Memorial Hospital, Linkou 333, Taiwan
| |
Collapse
|
23
|
Müller JH, Liebensteiner M, Kort N, Stirling P, Pilot P, Demey G. No significant difference in early clinical outcomes of custom versus off-the-shelf total knee arthroplasty: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2021; 31:1230-1246. [PMID: 34432095 DOI: 10.1007/s00167-021-06678-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 07/18/2021] [Indexed: 01/25/2023]
Abstract
PURPOSE The purpose of this systematic review and meta-analysis was to collect, synthesise and critically appraise findings of clinical studies that report outcomes of custom total knee arthroplasty (TKA). The hypothesis was that, compared to off-the-shelf (OTS) TKA, custom TKA would yield better surgical, clinical and radiographic outcomes. METHODS This systematic review and meta-analysis was performed in accordance with the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). On 8 February 2021, two authors independently searched and screened articles using MEDLINE®, Embase® and the Cochrane Library without restriction on date of publication. Findings from eligible articles were narratively synthesised and tabulated, and when ≥ 3 comparative studies reported the same outcome, results were pooled and summarised in forest plots. Quality assessments of the studies were done according to the guidelines of the Joanna Briggs Institute (JBI) Checklists. RESULTS A total of 15 articles were eligible for data extraction, of which 9 were case-control studies reporting on 929 custom versus 998 OTS TKA, 5 were case series reporting on results of 587 custom TKA, and 1 was a cross-sectional study reporting on results of 44 custom versus 132 OTS TKA. Five studies that compared early revision rates found the overall effect in favour of OTS TKA (odds ratio (OR), 0.4; p = n.s.) but the result did not reach statistical significance. Four studies found no statistically significant difference in KSS knee (standardised mean difference (SMD), - 0.10; p = n.s.) and function (SMD, 0.03; p = n.s.), and five studies found no statistically significant difference in range of motion (SMD, 0.02; p = n.s.). One study that compared bone-implant fit between custom and three OTS tibial components found no overhang but revealed under-coverage of up to 18% in knees with custom tibial baseplates. CONCLUSION Custom TKA demonstrated no significant benefits compared to OTS TKA in terms of pooled clinical outcomes, but had considerably higher early revision rates. The findings of the present systematic review and meta-analysis suggest the need for studies with better comparable groups and standardisation of reporting outcomes amongst studies, that could increase the quality of evidence and enable pooling of results in future meta-analyses. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
| | - Michael Liebensteiner
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria
| | - Nanne Kort
- CortoClinics, Schijndel, The Netherlands
| | | | | | - Guillaume Demey
- Lyon-Ortho-Clinic, Clinique de la Sauvegarde, Ramsay Santé, 29 Avenue des Sources, 69009, Lyon, France
| |
Collapse
|
24
|
Beckers L, Müller JH, Daxhelet J, Ratano S, Saffarini M, Aït-Si-Selmi T, Bonnin MP. Considerable inter-individual variability of tibial geometric ratios renders bone-implant mismatch unavoidable using off-the-shelf total knee arthroplasty: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2021; 31:1284-1298. [PMID: 34075491 DOI: 10.1007/s00167-021-06623-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 05/21/2021] [Indexed: 01/25/2023]
Abstract
PURPOSE The purpose of this systematic review and meta-analysis was to investigate the variability in tibial geometric ratios among knees of different sexes and races to determine whether commercially-available tibial baseplates accommodate the morphologic diversity. The hypothesis was that anthropometric studies report considerable variability of tibial geometric ratios among sexes and races. METHODS This systematic review and meta-analysis was performed according to the preferred reporting items for systematic reviews and meta-analyses (PRISMA) criteria. Two authors independently conducted an electronic search using MEDLINE® and Embase® on 28 January 2021 for clinical studies reporting on tibial geometric ratios. Tibial geometric ratios, as reported by the clinical studies, were represented by plotting their means and two standard deviations for comparison to two symmetric and two asymmetric commercially-available tibial baseplates. RESULTS A total of 27 articles that reported on a combined total of 20,944 knees were eligible for data extraction. Variation in tibial aspect ratios was equal among sexes. The greatest variation in aspect ratio was observed among East Asians, followed by Caucasians, African-Americans, Indian and Middle Easterns. The variation in tibial asymmetry ratio was larger among men compared to women. The greatest variation in asymmetry ratio was observed among African-Americans, followed by Caucasians, East Asians, Indian and Middle Easterns. Bone-implant mismatch of > 3 mm overhang or > 4 mm under-coverage with four commercially-available tibial baseplates occurred in large proportions of knees due to variations in aspect ratio (in 17-100% of knees) and asymmetry ratio (in 7-100% of knees). CONCLUSION Anthropometric studies reported considerable inter-individual variability of tibial geometric ratios, which exceeded effects of sexual dimorphism and racial diversity. Bone-implant mismatch may be unavoidable in a large proportion of knees, when considering that a surgeon generally only uses one or a few TKA brands. These findings support the drive towards patient-specific implants to potentially achieve accurate bone-implant fit by implant customisation. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Lucas Beckers
- Centre Orthopédique Santy, Ramsay Santé, Hôpital Privé Jean Mermoz, Lyon, France
| | | | - Jeremy Daxhelet
- Centre Orthopédique Santy, Ramsay Santé, Hôpital Privé Jean Mermoz, Lyon, France
| | - Salvatore Ratano
- Centre Orthopédique Santy, Ramsay Santé, Hôpital Privé Jean Mermoz, Lyon, France
| | - Mo Saffarini
- ReSurg SA, Rue Saint-Jean 22, 1260, Nyon, Switzerland.
| | - Tarik Aït-Si-Selmi
- Centre Orthopédique Santy, Ramsay Santé, Hôpital Privé Jean Mermoz, Lyon, France
| | - Michel P Bonnin
- Centre Orthopédique Santy, Ramsay Santé, Hôpital Privé Jean Mermoz, Lyon, France
| |
Collapse
|
25
|
Meier M, Calliess T, Tibesku C, Beckmann J. [New technologies (robotics, custom-made) in unicondylar knee arthroplasty-pro]. DER ORTHOPADE 2021; 50:130-135. [PMID: 33346868 DOI: 10.1007/s00132-020-04058-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND Unicondylar knee arthroplasty offers the advantage that partial degenerative changes can be addressed with partial prosthetic solutions, thus preserving as much of the native joint as possible, including the cruciate ligaments. On the other hand, the number of revisions is still higher than for total knee endoprosthetics. In the literature, the causes mentioned are insufficient fit of the components as well as surgical errors. The use of new technologies to achieve a better fit and higher surgical precision and reproducibility, therefore, represents a promising approach. INDIVIDUAL ENDOPROSTHETICS Individual endoprosthetics offers the advantage that the prosthesis is adapted to the individual anatomy of each patient and not the patient's anatomy to the prosthesis, as is the case with standard prostheses. This allows for an optimal fit of the prosthesis while avoiding excessive bone resections and soft tissue releases. ROBOTICS The use of robotics in endoprosthetics makes it easier to correctly perform bone resections and align components. This ensures high and reproducible precision even for surgeons with lower case numbers. Studies on individual unicondylar endoprosthetics and robotics are reporting promising results. However, long-term results of high-quality randomized studies must be awaited in order to make a scientifically sound statement.
Collapse
Affiliation(s)
- Malin Meier
- Universitätsklinik für Orthopädische Chirurgie und Traumatologie, Inselspital, Bern, Schweiz
| | | | | | - Johannes Beckmann
- Sportklinik Stuttgart, Taubenheimstr. 8, 70372, Stuttgart, Deutschland.
| |
Collapse
|
26
|
Müller JH, Li K, Reina N, Telmon N, Saffarini M, Cavaignac E. Sexual and ethnic polymorphism result in considerable mismatch between native trochlear geometry and off-the-shelf TKA prostheses. Knee Surg Sports Traumatol Arthrosc 2020; 28:3871-3878. [PMID: 32020254 DOI: 10.1007/s00167-020-05871-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Accepted: 01/20/2020] [Indexed: 12/26/2022]
Abstract
PURPOSE To determine if trochlear morphology in healthy knees depends on sex and ethnicity, and to compare it to off-the-shelf TKA prostheses. METHODS Three retrospective series of CT angiograms from France (female, 124; male, 135), China (female, 122; male, 137) and South Africa (female, 21; male, 62) were used to digitize osseous landmarks at the level of the femoral epicondyles. Sulcus angle, trochlear rotation, lateral trochlear inclination, trochlear asymmetry ratio, and trochlear depth index were quantified for each knee and for 10 total knee arthroplasty (TKA) models. Univariable regression analyses were performed to determine associations of the five trochlear parameters with sex and ethnicity. Interquartile ranges (IQR) of native trochlear parameters were compared to the trochlear parameters of 10 off-the-shelf TKA prostheses. RESULTS Compared to French knees, Chinese knees had greater sulcus angle (β = 6.3°, p < 0.001), trochlear rotation (β = 0.8°, p = 0.004) and trochlear depth index (β = 1.60, p < 0.001). Conversely, South African knees had greater trochlear rotation (β = 1.9°, p < 0.001) and lateral trochlear inclination (β = 3.7°, p < 0.001). Female knees had smaller trochlear asymmetry ratios (β = - 0.03, p = 0.05) but greater trochlear rotation angles (β = 0.7, p = 0.005). Considerable mismatches in trochlear morphology were revealed between native knees and off-the-shelf TKA prostheses. CONCLUSIONS The findings suggest that thresholds used in the diagnosis of patellofemoral instability should be adapted to patient sex and ethnicity, and that standard off-the-shelf TKA may not restore native trochlear parameters in all patients. LEVEL OF EVIDENCE III, retrospective comparative.
Collapse
Affiliation(s)
| | - Ke Li
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Nicolas Reina
- Laboratoire AMIS, UMR 5288 CNRS, Université Paul Sabatier, Toulouse, France.,Musculoskeletal Institute, Hôpital Pierre Paul Riquet, CHU Toulouse, Toulouse, France
| | - Norbert Telmon
- Laboratoire AMIS, UMR 5288 CNRS, Université Paul Sabatier, Toulouse, France
| | - Mo Saffarini
- ReSurg SA, Rue Saint Jean 22, 1260, Nyon, Switzerland.
| | - Etienne Cavaignac
- Laboratoire AMIS, UMR 5288 CNRS, Université Paul Sabatier, Toulouse, France.,Musculoskeletal Institute, Hôpital Pierre Paul Riquet, CHU Toulouse, Toulouse, France
| |
Collapse
|
27
|
Loures FB, de Araújo Góes RF, de Sousa EB, Cavanellas N, Barretto JM, Tamaoki MJS, Pires e Albuquerque RS, Labronici PJ. Intraoperative morphometric study of distal femur in Brazilian patients undergoing total knee arthroplasty. PLoS One 2020; 15:e0233715. [PMID: 32469996 PMCID: PMC7259597 DOI: 10.1371/journal.pone.0233715] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 05/11/2020] [Indexed: 12/02/2022] Open
Abstract
Background Total knee arthroplasty (TKA) is the treatment option for patients with severe osteoarthritis (OA) of the knee whose symptoms are refractory to conservative management. Unfortunately, the level of patient dissatisfaction is high, reaching up to 25%. The reasons for this dissatisfaction are multifactorial, but bone-implant mismatch significantly increases the chance of pain and functional limitation. Sex-specific prosthesis designs have been developed to overcome this issue, but their use is still controversial. The primary objective of this study was to evaluate possible sex differences in the shape of the distal femur in patients with osteoarthritis. Secondary objectives were to investigate interpersonal variability of the distal femur and to determine the number of femoral implant sizes required to meet shape variations. Methods and findings A cross-sectional observational study prospectively compared 294 knees of 293 patients with osteoarthritis according to sex (201 female/93 male). Six intraoperative measurements were performed on the distal femur (height and width of both lateral and medial condyles, total medial-lateral width of the femur, and intercondylar distance). Sex differences and interpersonal variability were analyzed by multiple linear regressions. Measurements were also correlated with patient height. An optimization analysis was used to estimate the number of femoral implant sizes required. There were significant sex differences in the distal femur, where men had higher values than women in all measurements. Great interpersonal variability was found. The height of the lateral condyle was correlated with patient height, but the correlation was not strong. Twenty-five femoral implant sizes were required to meet the shape variations in our sample. Conclusions The shape of the distal femur in patients with osteoarthritis shows great interpersonal variability, with men showing significantly higher values than women. A total of 25 different implant sizes would be necessary to adequately meet the variations observed in our study population.
Collapse
Affiliation(s)
- Fabrício Bolpato Loures
- Orthopedic Surgery Department, Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ, Brazil
- Orthopedic Surgery Department, Hospital Santa Teresa (HST), Petrópolis, RJ, Brazil
- * E-mail:
| | | | - Eduardo Branco de Sousa
- Orthopedic Surgery Department, Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, RJ, Brazil
| | - Naasson Cavanellas
- Orthopedic Surgery Department, Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, RJ, Brazil
| | - João Maurício Barretto
- Orthopedic Surgery Department, Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, RJ, Brazil
| | - Marcel Jun Sugawara Tamaoki
- Orthopedic Surgery Department, Escola Paulista de Ortopedia, Universidade Federal de São Paulo (UNIFESP), São Paulo, SP, Brazil
| | | | - Pedro José Labronici
- Orthopedic Surgery Department, Universidade Federal Fluminense (UFF), Niterói, RJ, Brazil
| |
Collapse
|
28
|
Lee JA, Koh YG, Kang KT. Biomechanical and Clinical Effect of Patient-Specific or Customized Knee Implants: A Review. J Clin Med 2020; 9:jcm9051559. [PMID: 32455733 PMCID: PMC7290390 DOI: 10.3390/jcm9051559] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 05/13/2020] [Accepted: 05/15/2020] [Indexed: 01/22/2023] Open
Abstract
(1) Background: Although knee arthroplasty or knee replacement is already an effective clinical treatment, it continues to undergo clinical and biomechanical improvements. For an increasing number of conditions, prosthesis based on an individual patient's anatomy is a promising treatment. The aims of this review were to evaluate the clinical and biomechanical efficacy of patient-specific knee prosthesis, explore its future direction, and summarize any published comparative studies. (2) Methods: We searched the PubMed, MEDLINE, Embase, and Scopus databases for articles published prior to February 1, 2020, with the keywords "customized knee prosthesis" and "patient-specific knee prosthesis". We excluded patient-specific instrument techniques. (3) Results: Fifty-seven articles met the inclusion criteria. In general, clinical improvement was greater with a patient-specific knee prosthesis than with a conventional knee prosthesis. In addition, patient-specific prosthesis showed improved biomechanical effect than conventional prosthesis. However, in one study, patient-specific unicompartmental knee arthroplasty showed a relatively high rate of aseptic loosening, particularly femoral component loosening, in the short- to medium-term follow-up. (4) Conclusions: A patient-specific prosthesis provides a more accurate resection and fit of components, yields significant postoperative improvements, and exhibits a high level of patient satisfaction over the short to medium term compared with a conventional prosthesis. However, the tibial insert design of the current patient-specific knee prosthesis does not follow the tibial plateau curvature.
Collapse
Affiliation(s)
- Jin-Ah Lee
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Korea;
| | - Yong-Gon Koh
- Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, Korea;
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Korea;
- Correspondence: ; Tel.: +82-2-588-1006
| |
Collapse
|
29
|
[Why individualized endoprosthetics for the knee?]. DER ORTHOPADE 2020; 49:378-381. [PMID: 32232522 DOI: 10.1007/s00132-020-03899-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|