1
|
Kara N, Ayoub N, Ilgu H, Fotiadis D, Ilgu M. Aptamers Targeting Membrane Proteins for Sensor and Diagnostic Applications. Molecules 2023; 28:molecules28093728. [PMID: 37175137 PMCID: PMC10180177 DOI: 10.3390/molecules28093728] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 04/07/2023] [Accepted: 04/19/2023] [Indexed: 05/15/2023] Open
Abstract
Many biological processes (physiological or pathological) are relevant to membrane proteins (MPs), which account for almost 30% of the total of human proteins. As such, MPs can serve as predictive molecular biomarkers for disease diagnosis and prognosis. Indeed, cell surface MPs are an important class of attractive targets of the currently prescribed therapeutic drugs and diagnostic molecules used in disease detection. The oligonucleotides known as aptamers can be selected against a particular target with high affinity and selectivity by iterative rounds of in vitro library evolution, known as Systematic Evolution of Ligands by EXponential Enrichment (SELEX). As an alternative to antibodies, aptamers offer unique features like thermal stability, low-cost, reuse, ease of chemical modification, and compatibility with various detection techniques. Particularly, immobilized-aptamer sensing platforms have been under investigation for diagnostics and have demonstrated significant value compared to other analytical techniques. These "aptasensors" can be classified into several types based on their working principle, which are commonly electrochemical, optical, or mass-sensitive. In this review, we review the studies on aptamer-based MP-sensing technologies for diagnostic applications and have included new methodological variations undertaken in recent years.
Collapse
Affiliation(s)
- Nilufer Kara
- Department of Biological Sciences, Middle East Technical University, Ankara 06800, Turkey
| | - Nooraldeen Ayoub
- Department of Biological Sciences, Middle East Technical University, Ankara 06800, Turkey
- Institute of Biochemistry and Molecular Medicine, University of Bern, CH-3012 Bern, Switzerland
| | - Huseyin Ilgu
- Institute of Biochemistry and Molecular Medicine, University of Bern, CH-3012 Bern, Switzerland
| | - Dimitrios Fotiadis
- Institute of Biochemistry and Molecular Medicine, University of Bern, CH-3012 Bern, Switzerland
| | - Muslum Ilgu
- Department of Biological Sciences, Middle East Technical University, Ankara 06800, Turkey
- Roy J. Carver Department of Biochemistry, Biophysics and Molecular Biology, Iowa State University, Ames, IA 50011, USA
- Department of Veterinary Microbiology and Preventive Medicine, Iowa State University, Ames, IA 50011, USA
- Aptalogic Inc., Ames, IA 50014, USA
| |
Collapse
|
2
|
Sannigrahi A, Rai VH, Chalil MV, Chakraborty D, Meher SK, Roy R. A Versatile Suspended Lipid Membrane System for Probing Membrane Remodeling and Disruption. MEMBRANES 2022; 12:1190. [PMID: 36557095 PMCID: PMC9784602 DOI: 10.3390/membranes12121190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 10/12/2022] [Accepted: 10/18/2022] [Indexed: 06/17/2023]
Abstract
Artificial membrane systems can serve as models to investigate molecular mechanisms of different cellular processes, including transport, pore formation, and viral fusion. However, the current, such as SUVs, GUVs, and the supported lipid bilayers suffer from issues, namely high curvature, heterogeneity, and surface artefacts, respectively. Freestanding membranes provide a facile solution to these issues, but current systems developed by various groups use silicon or aluminum oxide wafers for fabrication that involves access to a dedicated nanolithography facility and high cost while conferring poor membrane stability. Here, we report the development, characterization and applications of an easy-to-fabricate suspended lipid bilayer (SULB) membrane platform leveraging commercial track-etched porous filters (PCTE) with defined microwell size. Our SULB system offers a platform to study the lipid composition-dependent structural and functional properties of membranes with exceptional stability. With dye entrapped in PCTE microwells by SULB, we show that sphingomyelin significantly augments the activity of pore-forming toxin, Cytolysin A (ClyA) and the pore formation induces lipid exchange between the bilayer leaflets. Further, we demonstrate high efficiency and rapid kinetics of membrane fusion by dengue virus in our SULB platform. Our suspended bilayer membrane mimetic offers a novel platform to investigate a large class of biomembrane interactions and processes.
Collapse
|
3
|
Liu HY, Kumar R, Takai M, Hirtz M. Enhanced Stability of Lipid Structures by Dip-Pen Nanolithography on Block-Type MPC Copolymer. Molecules 2020; 25:E2768. [PMID: 32549371 PMCID: PMC7356513 DOI: 10.3390/molecules25122768] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 06/09/2020] [Accepted: 06/12/2020] [Indexed: 01/08/2023] Open
Abstract
Biomimetic lipid membranes on solid supports have been used in a plethora of applications, including as biosensors, in research on membrane proteins or as interfaces in cell experiments. For many of these applications, structured lipid membranes, e.g., in the form of arrays with features of different functionality, are highly desired. The stability of these features on a given substrate during storage and in incubation steps is key, while at the same time the substrate ideally should also exhibit antifouling properties. Here, we describe the highly beneficial properties of a 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymer for the stability of supported lipid membrane structures generated by dip-pen nanolithography with phospholipids (L-DPN). The MPC copolymer substrates allow for more stable and higher membrane stack structures in comparison to other hydrophilic substrates, like glass or silicon oxide surfaces. The structures remain highly stable under immersion in liquid and subsequent incubation and washing steps. This allows multiplexed functionalization of lipid arrays with antibodies via microchannel cantilever spotting (µCS), without the need of orthogonal binding tags for each antibody type. The combined properties of the MPC copolymer substrate demonstrate a great potential for lipid-based biomedical sensing and diagnostic platforms.
Collapse
Affiliation(s)
- Hui-Yu Liu
- Institute of Nanotechnology (INT) & Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (H.-Y.L.); (R.K.)
| | - Ravi Kumar
- Institute of Nanotechnology (INT) & Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (H.-Y.L.); (R.K.)
| | - Madoka Takai
- Department of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo 113-8656, Japan;
| | - Michael Hirtz
- Institute of Nanotechnology (INT) & Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (H.-Y.L.); (R.K.)
| |
Collapse
|
4
|
Mazur F, Bally M, Städler B, Chandrawati R. Liposomes and lipid bilayers in biosensors. Adv Colloid Interface Sci 2017; 249:88-99. [PMID: 28602208 DOI: 10.1016/j.cis.2017.05.020] [Citation(s) in RCA: 90] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 05/30/2017] [Indexed: 10/19/2022]
Abstract
Biosensors for the rapid, specific, and sensitive detection of analytes play a vital role in healthcare, drug discovery, food safety, and environmental monitoring. Although a number of sensing concepts and devices have been developed, many longstanding challenges to obtain inexpensive, easy-to-use, and reliable sensor platforms remain largely unmet. Nanomaterials offer exciting possibilities for enhancing the assay sensitivity and for lowering the detection limits down to single-molecule resolution. In this review, we present an overview of liposomes and lipid bilayers in biosensing applications. Lipid assemblies in the form of spherical liposomes or two-dimensional planar membranes have been widely used in the design of biosensing assays; in particular, we highlight a number of recent promising developments of biosensors based on liposomes in suspension, liposome arrays, and lipid bilayers arrays. Assay sensitivity and specificity are discussed, advantages and drawbacks are reviewed, and possible further developments are outlined.
Collapse
|
5
|
A Low-Noise Transimpedance Amplifier for BLM-Based Ion Channel Recording. SENSORS 2016; 16:s16050709. [PMID: 27213382 PMCID: PMC4883400 DOI: 10.3390/s16050709] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Revised: 04/13/2016] [Accepted: 05/05/2016] [Indexed: 11/17/2022]
Abstract
High-throughput screening (HTS) using ion channel recording is a powerful drug discovery technique in pharmacology. Ion channel recording with planar bilayer lipid membranes (BLM) is scalable and has very high sensitivity. A HTS system based on BLM ion channel recording faces three main challenges: (i) design of scalable microfluidic devices; (ii) design of compact ultra-low-noise transimpedance amplifiers able to detect currents in the pA range with bandwidth >10 kHz; (iii) design of compact, robust and scalable systems that integrate these two elements. This paper presents a low-noise transimpedance amplifier with integrated A/D conversion realized in CMOS 0.35 μm technology. The CMOS amplifier acquires currents in the range ±200 pA and ±20 nA, with 100 kHz bandwidth while dissipating 41 mW. An integrated digital offset compensation loop balances any voltage offsets from Ag/AgCl electrodes. The measured open-input input-referred noise current is as low as 4 fA/√Hz at ±200 pA range. The current amplifier is embedded in an integrated platform, together with a microfluidic device, for current recording from ion channels. Gramicidin-A, α-haemolysin and KcsA potassium channels have been used to prove both the platform and the current-to-digital converter.
Collapse
|
6
|
|
7
|
del Rio Martinez JM, Zaitseva E, Petersen S, Baaken G, Behrends JC. Automated formation of lipid membrane microarrays for ionic single-molecule sensing with protein nanopores. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2015; 11:119-125. [PMID: 25115837 DOI: 10.1002/smll.201402016] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2014] [Indexed: 06/03/2023]
Abstract
Efficient use of membrane protein nanopores in ionic single-molecule sensing requires technology for the reliable formation of suspended molecular membranes densely arrayed in formats that allow high-resolution electrical recording. Here, automated formation of bimolecular lipid layers is shown using a simple process where a poly(tetrafluoroethylene)-coated magnetic bar is remotely actuated to perform a turning motion, thereby spreading phospholipid in organic solvent on a nonpolar surface containing a <1 mm(2) 4 × 4 array of apertures with embedded microelectrodes (microelectrode cavity array). Parallel and high-resolution single-molecule detection by single nanopores is demonstrated on the resulting bilayer arrays, which are shown to form by a classical but very rapid self-assembly process. The technique provides a robust and scalable solution for the problem of reliable, automated formation of multiple independent lipid bilayers in a dense microarray format, while preserving the favorable electrical properties of the microelectrode cavity array.
Collapse
Affiliation(s)
- Juan M del Rio Martinez
- Laboratory for Membrane Physiology and -Technology, Department of Physiology, University of Freiburg, Hermann-Herder-Str. 7, 79104, Freiburg, Germany
| | | | | | | | | |
Collapse
|
8
|
Gleisner M, Mey I, Barbot M, Dreker C, Meinecke M, Steinem C. Driving a planar model system into the 3(rd) dimension: generation and control of curved pore-spanning membrane arrays. SOFT MATTER 2014; 10:6228-6236. [PMID: 25012509 DOI: 10.1039/c4sm00702f] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The generation of a regular array of micrometre-sized pore-spanning membranes that protrude from the underlying surface as a function of osmotic pressure is reported. Giant unilamellar vesicles are spread onto non-functionalized Si/SiO(2) substrates containing a highly ordered array of cavities with pore diameters of 850 nm, an interpore distance of 4 μm and a pore depth of 10 μm. The shape of the resulting pore-spanning membranes is controlled by applying an osmotic pressure difference between the bulk solution and the femtoliter-sized cavity underneath each membrane. By applying Young-Laplace's law assuming moderate lateral membrane tensions, the response of the membranes to the osmotic pressure difference can be theoretically well described. Protruded pore-spanning membranes containing the receptor lipid PIP(2) specifically bind the ENTH domain of epsin resulting in an enlargement of the protrusions and disappearance as a result of ENTH-domain induced defects in the membranes. These results are discussed in the context of an ENTH-domain induced reduction of lateral membrane tension and formation of defects as a result of helix insertion of the protein in the bilayer.
Collapse
Affiliation(s)
- Martin Gleisner
- Institute of Organic and Biomolecular Chemistry, University of Göttingen, Tammannstrasse 2, 37077 Göttingen, Germany.
| | | | | | | | | | | |
Collapse
|
9
|
Liu Q, Wu C, Cai H, Hu N, Zhou J, Wang P. Cell-based biosensors and their application in biomedicine. Chem Rev 2014; 114:6423-61. [PMID: 24905074 DOI: 10.1021/cr2003129] [Citation(s) in RCA: 185] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Qingjun Liu
- Biosensor National Special Laboratory, Key Laboratory of Biomedical Engineering of the Ministry of Education, Department of Biomedical Engineering, Zhejiang University , Hangzhou 310027, China
| | | | | | | | | | | |
Collapse
|
10
|
Urban M, Kleefen A, Mukherjee N, Seelheim P, Windschiegl B, Vor der Brüggen M, Koçer A, Tampé R. Highly parallel transport recordings on a membrane-on-nanopore chip at single molecule resolution. NANO LETTERS 2014; 14:1674-80. [PMID: 24524682 PMCID: PMC3953990 DOI: 10.1021/nl5002873] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 02/08/2014] [Indexed: 05/21/2023]
Abstract
Membrane proteins are prime drug targets as they control the transit of information, ions, and solutes across membranes. Here, we present a membrane-on-nanopore platform to analyze nonelectrogenic channels and transporters that are typically not accessible by electrophysiological methods in a multiplexed manner. The silicon chip contains 250,000 femtoliter cavities, closed by a silicon dioxide top layer with defined nanopores. Lipid vesicles containing membrane proteins of interest are spread onto the nanopore-chip surface. Transport events of ligand-gated channels were recorded at single-molecule resolution by high-parallel fluorescence decoding.
Collapse
Affiliation(s)
- Michael Urban
- Institute
of Biochemistry, Biocenter, Goethe-University, Frankfurt, Germany
| | - Alexander Kleefen
- Institute
of Biochemistry, Biocenter, Goethe-University, Frankfurt, Germany
| | - Nobina Mukherjee
- Department
of Biochemistry, University of Groningen, The Netherlands
| | | | | | | | - Armagan Koçer
- Department
of Biochemistry, University of Groningen, The Netherlands
| | - Robert Tampé
- Institute
of Biochemistry, Biocenter, Goethe-University, Frankfurt, Germany
- Cluster
of Excellence − Macromolecular Complexes, Goethe-University, Frankfurt, Germany
| |
Collapse
|
11
|
Kawano R, Tsuji Y, Sato K, Osaki T, Kamiya K, Hirano M, Ide T, Miki N, Takeuchi S. Automated parallel recordings of topologically identified single ion channels. Sci Rep 2013; 3:1995. [PMID: 23771282 PMCID: PMC3683667 DOI: 10.1038/srep01995] [Citation(s) in RCA: 101] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Accepted: 05/30/2013] [Indexed: 02/07/2023] Open
Abstract
Although ion channels are attractive targets for drug discovery, the systematic screening of ion channel-targeted drugs remains challenging. To facilitate automated single ion-channel recordings for the analysis of drug interactions with the intra- and extracellular domain, we have developed a parallel recording methodology using artificial cell membranes. The use of stable lipid bilayer formation in droplet chamber arrays facilitated automated, parallel, single-channel recording from reconstituted native and mutated ion channels. Using this system, several types of ion channels, including mutated forms, were characterised by determining the protein orientation. In addition, we provide evidence that both intra- and extracellular amyloid-beta fragments directly inhibit the channel open probability of the hBK channel. This automated methodology provides a high-throughput drug screening system for the targeting of ion channels and a data-intensive analysis technique for studying ion channel gating mechanisms.
Collapse
Affiliation(s)
- Ryuji Kawano
- BioMicrosystems Project, Kanagawa Academy of Science and Technology (KAST), Kawasaki, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Leptihn S, Castell OK, Cronin B, Lee EH, Gross LCM, Marshall DP, Thompson JR, Holden M, Wallace MI. Constructing droplet interface bilayers from the contact of aqueous droplets in oil. Nat Protoc 2013; 8:1048-57. [DOI: 10.1038/nprot.2013.061] [Citation(s) in RCA: 102] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
13
|
Tsuji Y, Kawano R, Osaki T, Kamiya K, Miki N, Takeuchi S. Droplet-based lipid bilayer system integrated with microfluidic channels for solution exchange. LAB ON A CHIP 2013; 13:1476-81. [PMID: 23450304 DOI: 10.1039/c3lc41359d] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
This paper proposes a solution exchange of a droplet-based lipid bilayer system, in which the inner solution of a droplet is replaced for the purpose of efficient ion channel analyses. In our previous report, we successfully recorded the channel conductance of alpha-hemolysin in a bilayer lipid membrane using a droplet contact method that can create a spontaneous lipid bilayer at the interface of contacting droplets; this method is widely used as highly efficient method for preparing planar lipid membranes. When only pipetting droplets of the solution, this method is highly efficient for preparing lipid membranes. However, the drawback of droplet-based systems is their inability to exchange the solution within the droplets. To study the effect of inhibitors and promoters of ion channels in drug discovery, it would be beneficial to conduct a solution exchange of droplets to introduce membrane proteins and to apply or wash-out the chemicals. In this study, we propose a droplet contact method that allows for the solution exchange of droplets via microfluidic channels. We experimentally and numerically investigated the bilayer stability with respect to exchanging flow rates, and then demonstrated a binding assay of an alpha-hemolysin using one of its blockers. The solution exchange in this system was conducted in less than 20 s without rupturing the membrane. We believe that the proposed system will enhance the efficiency of ion channel analyses.
Collapse
Affiliation(s)
- Yutaro Tsuji
- Kanagawa Academy of Science and Technology (KAST), KSP EAST 303, 3-2-1, Sakado, Kawasaki, Kanagawa, Japan
| | | | | | | | | | | |
Collapse
|
14
|
Stimberg VC, Bomer JG, van Uitert I, van den Berg A, Le Gac S. High yield, reproducible and quasi-automated bilayer formation in a microfluidic format. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2013; 9:1076-1085. [PMID: 23139010 DOI: 10.1002/smll.201201821] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Revised: 08/27/2012] [Indexed: 05/28/2023]
Abstract
A microfluidic platform is reported for various experimentation schemes on cell membrane models and membrane proteins using a combination of electrical and optical measurements, including confocal microscopy. Bilayer lipid membranes (BLMs) are prepared in the device upon spontaneous and instantaneous thinning of the lipid solution in a 100-μm dry-etched aperture in a 12.5-μm thick Teflon foil. Using this quasi-automated approach, a remarkable 100% membrane formation yield is reached (including reflushing in 4% of the cases), and BLMs are stable for up to 36 h. Furthermore, the potential of this platform is demonstrated for (i) the in-depth characterization of BLMs comprising both synthetic and natural lipids (1,2-diphytanoyl-sn-glycero-3-phosphocholine (DPhPC) and L-α-phosphatidylcholine (L-α-PC)/cholesterol, respectively) in terms of seal resistance, capacitance, surface area, specific capacitance, and membrane hydrophobic thickness; (ii) confocal microscopy imaging of phase separation in sphingomyelin/L-α-PC/cholesterol ternary membranes; (iii) electrical measurements of individual nanopores (α-hemolysin, gramicidin); and (iv) indirect assessment of the alteration of membrane properties upon exposure to chemical stimuli using the natural nanopore gramicidin as a sensor.
Collapse
Affiliation(s)
- Verena C Stimberg
- BIOS-Lab on a Chip Group, MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
| | | | | | | | | |
Collapse
|
15
|
Effects of Micromachining Processes on Electro-Osmotic Flow Mobility of Glass Surfaces. MICROMACHINES 2013. [DOI: 10.3390/mi4010067] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
16
|
Shim JS, Geng J, Ahn CH, Guo P. Formation of lipid bilayers inside microfluidic channel array for monitoring membrane-embedded nanopores of phi29 DNA packaging nanomotor. Biomed Microdevices 2013; 14:921-8. [PMID: 22773160 DOI: 10.1007/s10544-012-9671-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
An efficient method to form lipid bilayers inside an array of microfluidic channels has been developed and applied to monitor the membrane-embedded phi29 DNA packaging motor with an electrochemical characterization on a lab-on-a-chip (LOC) platform. A push-pull junction capturing approach was applied to confine a small amount of the lipid solution inside a microchannel. The selective permeability between solvents and water in PDMS was utilized to extract the solvent from the lipid solution, resulting in a self-formation of the lipid bilayer in the microchannel array. Each microchannel was independently connected to a silver/silver chloride (Ag/AgCl) electrode array, leading to a high-throughput monitoring of the nanopore insertion in the formed lipid bilayers. The formation of multiple lipid bilayers inside an array of microchannels and the simultaneous electrical and optical monitoring of multiple bilayer provides an efficient LOC platform for the further development of single phi29 motor pore sensing and high throughput single pore dsDNA sequencing.
Collapse
Affiliation(s)
- Joon S Shim
- College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA
| | | | | | | |
Collapse
|
17
|
Frese D, Steltenkamp S, Schmitz S, Steinem C. In situ generation of electrochemical gradients across pore-spanning membranes. RSC Adv 2013. [DOI: 10.1039/c3ra42723d] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
18
|
|
19
|
Abstract
Lipid bilayers are natural barriers of biological cells and cellular compartments. Membrane proteins integrated in biological membranes enable vital cell functions such as signal transduction and the transport of ions or small molecules. In order to determine the activity of a protein of interest at defined conditions, the membrane protein has to be integrated into artificial lipid bilayers immobilized on a surface. For the fabrication of such biosensors expertise is required in material science, surface and analytical chemistry, molecular biology and biotechnology. Specifically, techniques are needed for structuring surfaces in the micro- and nanometer scale, chemical modification and analysis, lipid bilayer formation, protein expression, purification and solubilization, and most importantly, protein integration into engineered lipid bilayers. Electrochemical and optical methods are suitable to detect membrane activity-related signals. The importance of structural knowledge to understand membrane protein function is obvious. Presently only a few structures of membrane proteins are solved at atomic resolution. Functional assays together with known structures of individual membrane proteins will contribute to a better understanding of vital biological processes occurring at biological membranes. Such assays will be utilized in the discovery of drugs, since membrane proteins are major drug targets.
Collapse
|
20
|
Abstract
The field of microfluidics or lab-on-a-chip technology aims to improve and extend the possibilities of bioassays, cell biology and biomedical research based on the idea of miniaturization. Microfluidic systems allow more accurate modelling of physiological situations for both fundamental research and drug development, and enable systematic high-volume testing for various aspects of drug discovery. Microfluidic systems are in development that not only model biological environments but also physically mimic biological tissues and organs; such 'organs on a chip' could have an important role in expediting early stages of drug discovery and help reduce reliance on animal testing. This Review highlights the latest lab-on-a-chip technologies for drug discovery and discusses the potential for future developments in this field.
Collapse
|
21
|
Matosevic S. Synthesizing artificial cells from giant unilamellar vesicles: State-of-the art in the development of microfluidic technology. Bioessays 2012; 34:992-1001. [DOI: 10.1002/bies.201200105] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
22
|
Zagnoni M. Miniaturised technologies for the development of artificial lipid bilayer systems. LAB ON A CHIP 2012; 12:1026-1039. [PMID: 22301684 DOI: 10.1039/c2lc20991h] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Artificially reproducing cellular environments is a key aim of synthetic biology, which has the potential to greatly enhance our understanding of cellular mechanisms. Microfluidic and lab-on-a-chip (LOC) techniques, which enable the controlled handling of sub-microlitre volumes of fluids in an automated and high-throughput manner, can play a major role in achieving this by offering alternative and powerful methodologies in an on-chip format. Such techniques have been successfully employed over the last twenty years to provide innovative solutions for chemical analysis and cell-, molecular- and synthetic- biology. In the context of the latter, the formation of artificial cell membranes (or artificial lipid bilayers) that incorporate membrane proteins within miniaturised LOC architectures offers huge potential for the development of highly sensitive molecular sensors and drug screening applications. The aim of this review is to give a comprehensive and critical overview of the field of microsystems for creating and exploiting artificial lipid bilayers. Advantages and limitations of three of the most popular approaches, namely suspended, supported and droplet-based lipid bilayers, are discussed. Examples are reported that show how artificial cell membrane microsystems, by combining together biological procedures and engineering techniques, can provide novel methodologies for basic biological and biophysical research and for the development of biotechnology tools.
Collapse
Affiliation(s)
- Michele Zagnoni
- Centre for Microsystems and Photonics, University of Strathclyde, Glasgow, UK.
| |
Collapse
|
23
|
Steller L, Kreir M, Salzer R. Natural and artificial ion channels for biosensing platforms. Anal Bioanal Chem 2011; 402:209-30. [PMID: 22080413 DOI: 10.1007/s00216-011-5517-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2011] [Revised: 10/14/2011] [Accepted: 10/18/2011] [Indexed: 10/15/2022]
Abstract
The single-molecule selectivity and specificity of the binding process together with the expected intrinsic gain factor obtained when utilizing flow through a channel have attracted the attention of analytical chemists for two decades. Sensitive and selective ion channel biosensors for high-throughput screening are having an increasing impact on modern medical care, drug screening, environmental monitoring, food safety, and biowarefare control. Even virus antigens can be detected by ion channel biosensors. The study of ion channels and other transmembrane proteins is expected to lead to the development of new medications and therapies for a wide range of illnesses. From the first attempts to use membrane proteins as the receptive part of a sensor, ion channels have been engineered as chemical sensors. Several other types of peptidic or nonpeptidic channels have been investigated. Various gating mechanisms have been implemented in their pores. Three technical problems had to be solved to achieve practical biosensors based on ion channels: the fabrication of stable lipid bilayer membranes, the incorporation of a receptor into such a structure, and the marriage of the modified membrane to a transducer. The current status of these three areas of research, together with typical applications of ion-channel biosensors, are discussed in this review.
Collapse
Affiliation(s)
- L Steller
- Department of Magnetic and Acoustic Resonances, Leibniz Institute for Solid State and Materials Research, Dresden, Germany.
| | | | | |
Collapse
|
24
|
Takinoue M, Takeuchi S. Droplet microfluidics for the study of artificial cells. Anal Bioanal Chem 2011; 400:1705-16. [PMID: 21523331 DOI: 10.1007/s00216-011-4984-5] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2011] [Accepted: 04/02/2011] [Indexed: 11/26/2022]
Abstract
In this review, we describe recent advances in droplet-based microfluidics technology that can be applied in studies of artificial cells. Artificial cells are simplified models of living cells and provide valuable model platforms designed to reveal the functions of biological systems. The study of artificial cells is promoted by microfluidics technologies, which provide control over tiny volumes of solutions during quantitative chemical experiments and other manipulations. Here, we focus on current and future trends in droplet microfluidics and their applications in studies of artificial cells.
Collapse
Affiliation(s)
- Masahiro Takinoue
- Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan.
| | | |
Collapse
|
25
|
Kleefen A, Pedone D, Grunwald C, Wei R, Firnkes M, Abstreiter G, Rant U, Tampé R. Multiplexed parallel single transport recordings on nanopore arrays. NANO LETTERS 2010; 10:5080-7. [PMID: 20979410 DOI: 10.1021/nl1033528] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We introduce a nanofabricated silicon chip for massively multiplexed analysis of membrane channels and transporters in suspended lipid membranes that does not require any surface modification or organic solvent. Transport processes through single membrane complexes are monitored by fluorescence. The chip consists of an array of well-defined nanopores, addressing an individual pyramidal back-reflecting 30-fL compartment. The setup allows simultaneous analyses of ∼1,000 single transmembrane events in one field of view, observing translocation kinetics of transmembrane complexes.
Collapse
Affiliation(s)
- Alexander Kleefen
- Institute of Biochemistry, Biocenter, Center for Membrane Proteomics (CMP), and Cluster of Excellence Frankfurt (CEF)-Macromolecular Complexes, Goethe-University Frankfurt, Max-von-Laue-Strasse 9, D-60438 Frankfurt/M., Germany
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Wang T, Ingram C, Weisshaar JC. Model lipid bilayer with facile diffusion of lipids and integral membrane proteins. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010; 26:11157-64. [PMID: 20459075 PMCID: PMC5814108 DOI: 10.1021/la101046r] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A model membrane system is formed by the rupture of giant unilamellar vesicles (GUVs) onto a passivating layer comprising a PEG polymer cushion anchored in a lipid bilayer supported on glass. The novel use of pH-dependent electrostatic interactions between NeutrAvidin in the passivating layer and anionic lipids in the GUV drives vesicle rupture. The resulting "GUV pancakes" are single, planar lipid bilayer patches whose diameters vary from approximately 20 to 50 microm. The pancakes have several potential advantages for the in vitro study of protein-lipid interactions and integral membrane protein function. All components are commercially available. The pancakes resist nonspecific binding of vesicles containing protein. Both lipids and integral membrane proteins exhibit good lateral mobility in the GUV pancakes, as evidenced by single-particle tracking (SPT) of the DiD double-tailed fluorescent probe and of the integral membrane protein syntaxin-1A, labeled with AlexaFluor 633 (AF633-Syx). At least 80% of both probes exhibit free, homogeneous diffusion with a diffusion coefficient of approximately 5.5 microm(2) s(-1), which is more than 10 times faster than diffusion in a GUV pancake supported on bare glass. Atomic force microscopy (AFM) suggests that the polymer cushion has a height of approximately 4 nm. The mobility of a large fraction of the AF633-Syx probe suggests that even integral membrane proteins with large domains on both sides of the lipid bilayer should exhibit free diffusion within a GUV pancake.
Collapse
Affiliation(s)
- Tingting Wang
- Department of Chemistry, Graduate Program in Molecular Biophysics, 1101 University Avenue, University of Wisconsin—Madison, Madison, Wisconsin 53706
| | - Colin Ingram
- Department of Chemistry, Graduate Program in Molecular Biophysics, 1101 University Avenue, University of Wisconsin—Madison, Madison, Wisconsin 53706
| | - James C. Weisshaar
- Department of Chemistry, Graduate Program in Molecular Biophysics, 1101 University Avenue, University of Wisconsin—Madison, Madison, Wisconsin 53706
| |
Collapse
|
27
|
Weirich KL, Israelachvili JN, Fygenson DK. Bilayer edges catalyze supported lipid bilayer formation. Biophys J 2010; 98:85-92. [PMID: 20085721 PMCID: PMC2800963 DOI: 10.1016/j.bpj.2009.09.050] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2009] [Revised: 09/18/2009] [Accepted: 09/24/2009] [Indexed: 11/30/2022] Open
Abstract
Supported lipid bilayers (SLB) are important for the study of membrane-based phenomena and as coatings for biosensors. Nevertheless, there is a fundamental lack of understanding of the process by which they form from vesicles in solution. We report insights into the mechanism of SLB formation by vesicle adsorption using temperature-controlled time-resolved fluorescence microscopy at low vesicle concentrations. First, lipid accumulates on the surface at a constant rate up to approximately 0.8 of SLB coverage. Then, as patches of SLB nucleate and spread, the rate of accumulation increases. At a coverage of approximately 1.5 x SLB, excess vesicles desorb as SLB patches rapidly coalesce into a continuous SLB. Variable surface fluorescence immediately before SLB patch formation argues against the existence of a critical vesicle density necessary for rupture. The accelerating rate of accumulation and the widespread, abrupt loss of vesicles coincide with the emergence and disappearance of patch edges. We conclude that SLB edges enhance vesicle adhesion to the surface and induce vesicle rupture, thus playing a key role in the formation of continuous SLB.
Collapse
Affiliation(s)
- Kimberly L. Weirich
- Biomolecular Science and Engineering Program, University of California, Santa Barbara, California
| | - Jacob N. Israelachvili
- Biomolecular Science and Engineering Program, University of California, Santa Barbara, California
- Chemical Engineering Department, University of California, Santa Barbara, California
| | - D. Kuchnir Fygenson
- Biomolecular Science and Engineering Program, University of California, Santa Barbara, California
- Physics Department, University of California, Santa Barbara, California
| |
Collapse
|
28
|
van Uitert I, Le Gac S, van den Berg A. The influence of different membrane components on the electrical stability of bilayer lipid membranes. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2010; 1798:21-31. [DOI: 10.1016/j.bbamem.2009.10.003] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2009] [Revised: 10/01/2009] [Accepted: 10/06/2009] [Indexed: 11/25/2022]
|
29
|
Zhang X, Zhu Z, Sun C, Zhu F, Luo Z, Yan J, Mao B. Colloidal lithography-based fabrication of suspended nanoporous silicon nitride membranes. Mikrochim Acta 2009. [DOI: 10.1007/s00604-009-0216-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
30
|
Studer A, Han X, Winkler FK, Tiefenauer LX. Formation of individual protein channels in lipid bilayers suspended in nanopores. Colloids Surf B Biointerfaces 2009; 73:325-31. [DOI: 10.1016/j.colsurfb.2009.06.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2009] [Revised: 05/29/2009] [Accepted: 06/02/2009] [Indexed: 11/16/2022]
|
31
|
Hansen JS, Perry M, Vogel J, Groth JS, Vissing T, Larsen MS, Geschke O, Emneús J, Bohr H, Nielsen CH. Large scale biomimetic membrane arrays. Anal Bioanal Chem 2009; 395:719-27. [DOI: 10.1007/s00216-009-3010-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2009] [Revised: 07/22/2009] [Accepted: 07/23/2009] [Indexed: 10/20/2022]
|