1
|
Su H, Huang MZ, Shiea J, Lee CW. Thermal desorption ambient ionization mass spectrometry for emergency toxicology. MASS SPECTROMETRY REVIEWS 2022:e21784. [PMID: 35603997 DOI: 10.1002/mas.21784] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 12/17/2021] [Accepted: 01/21/2022] [Indexed: 06/15/2023]
Abstract
In the emergency department, it is important to rapidly identify the toxic substances that have led to acute poisoning because different toxicants or toxins cause poisoning through different mechanisms, requiring disparate therapeutic strategies and precautions against contraindicating actions, and diverse directions of clinical course monitoring and prediction of prognosis. Ambient ionization mass spectrometry, a state-of-the-art technology, has been proved to be a fast, accurate, and user-friendly tool for rapidly identifying toxicants like residual pesticides on fruits and vegetables. In view of this, developing an analytical platform that explores the application of such a cutting-edge technology in a novel direction has been initiated a research program, namely, the rapid identification of toxic substances which might have caused acute poisoning in patients who visit the emergency department and requires an accurate diagnosis for correct clinical decision-making to bring about corresponding data-guided management. This review includes (i) a narrative account of the breakthrough in emergency toxicology brought about by the advent of ambient ionization mass spectrometry and (ii) a thorough discussion about the clinical implications and technical limitations of such a promising innovation for promoting toxicological tests from tier two-level to tier one level.
Collapse
Affiliation(s)
- Hung Su
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Min-Zong Huang
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Jentaie Shiea
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, Taiwan
- Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chi-Wei Lee
- Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung, Taiwan
| |
Collapse
|
2
|
Yin XF, Wang QY, Ren FZ, Pang GF, Zhang XX, Li YX. Efficiency and mechanism of C 18-functionalized magnetic nanoparticles for extracting weakly polar pesticides from human serum determined by UHPLC-QTOF-MS and molecular dynamics simulations. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 293:118489. [PMID: 34780754 DOI: 10.1016/j.envpol.2021.118489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 11/03/2021] [Accepted: 11/10/2021] [Indexed: 06/13/2023]
Abstract
Detecting pesticide residues in human serum is a challenging process due to trace-level chronic exposure. Several methods using magnetic adsorbents have been developed for analyzing pesticide residue levels in human serum, but it is still difficult to achieve lower quantitative levels, and the adsorption mechanism for extracting pesticides is unclear. Herein, we propose a feasibility concept of using C18-functionalized magnetic nanoparticles for the adsorption of target pesticides, focusing on the extensively used weakly polar pesticides based on molecular dynamics (MD) simulations. To support this, the facilitated target nanoparticles of Fe3O4@SiO2-C18 were synthesized at a size of 12-13 nm with a magnetic saturation of 40 emu/g. After optimizing and establishing the extraction conditions (1.8 mL C18 modifier, 10 mg sorbents, 3 min adsorption time, 1000 μL ACN for desorption eluent at pH 3.8 and 5 min desorption time), which exhibited recovery = 72.3%-118.3% with RSDs = 0.03-6.57, linearity at 0.01-10 ng/mL with R2 = 0.9561-0.9993, and LODs = 0.01-0.30 ng/mL for the 11 weakly polar pesticides in human serum. Furthermore, the mechanism by which the C18 group selectively extracts weakly polar pesticides was confirmed by binding van der Waals and electrostatic interactions under stable and strong binding energy. The extraction process of efficient adsorption and desorption with C18 functional magnetite nanoparticles suggests a simple method for detecting weakly polar pesticides. The concept may lead to a general approach to analyzing multiple pesticide residues in human serum at trace levels.
Collapse
Affiliation(s)
- Xue-Feng Yin
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Food Science and Nutritional Engineering, China Agricultural University, Beijing, 100083, China
| | - Qing-Yu Wang
- Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100083, China; The Key Laboratory of Geriatrics, Beijing Institute of Geriatrics, Beijing Hospital, National Center of Gerontology, National Health Commission, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Fa-Zheng Ren
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Food Science and Nutritional Engineering, China Agricultural University, Beijing, 100083, China; Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100083, China
| | - Guo-Fang Pang
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Food Science and Nutritional Engineering, China Agricultural University, Beijing, 100083, China
| | - Xiao-Xu Zhang
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Food Science and Nutritional Engineering, China Agricultural University, Beijing, 100083, China
| | - Yi-Xuan Li
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Food Science and Nutritional Engineering, China Agricultural University, Beijing, 100083, China; Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100083, China.
| |
Collapse
|
3
|
Cetrangolo GP, Gori C, Rusko J, Terreri S, Manco G, Cimmino A, Febbraio F. Determination of Picomolar Concentrations of Paraoxon in Human Urine by Fluorescence-Based Enzymatic Assay. SENSORS 2019; 19:s19224852. [PMID: 31703397 PMCID: PMC6891394 DOI: 10.3390/s19224852] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 10/28/2019] [Accepted: 11/06/2019] [Indexed: 01/31/2023]
Abstract
Organophosphate (OP) pesticides are widely used in the agricultural field and in the prevention of pest infestation in private and public areas of cities. Despite their unquestionable utility, several of these compounds demonstrate toxic effects to the environment and human health. In particular, the occurrence of some organophosphate pesticides is correlated to the incidence of nervous system disorders, especially in children. The detection of pesticide residues in the human body represents an important task to preserve human health. In our work we propose the use of esterase-based biosensors as a viable alternative to the expensive and time-consuming systems currently used for their detection in human fluids. Using the esterase-2 activity, coupled with a fluorescence inhibition assay, we are able to detect very low concentration levels of diethyl (4-nitrophenyl) phosphate (paraoxon) in the range of the femtomole (fmol). Method robustness tests indicate the stability of esterase-2 in a diluted solution of 4% human urine, and we are able to accurately determine concentration levels of paraoxon in the range from 0.1 to 2 picomoles (pmol). The system sensitivity for OP detection is calculated at 524 ± 14.15 fmol of paraoxon recognized at 10% of inhibition, with an estimated limit of quantification of 262 ± 8.12 pmol mL-1. These values are comparable with the most recent analysis methods based on mass spectrometry carried out on human samples for pesticide detection. This research represents a starting point to develop cheap and fast testing methods for a rapid screening of toxic substances in human samples.
Collapse
Affiliation(s)
- Giovanni Paolo Cetrangolo
- Institute of Biochemistry and Cellular Biology – National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy; (G.P.C.); (C.G.); (J.R.)
| | - Carla Gori
- Institute of Biochemistry and Cellular Biology – National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy; (G.P.C.); (C.G.); (J.R.)
| | - Janis Rusko
- Institute of Biochemistry and Cellular Biology – National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy; (G.P.C.); (C.G.); (J.R.)
- Institute of Food Safety, Animal Health and Environment “BIOR”, Lejupes street 3, LV-1076 Riga, Latvia
| | - Sara Terreri
- Institute of Genetics and Biophysics “Adriano Buzzati Traverso”–National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy; (S.T.); (A.C.)
| | - Giuseppe Manco
- Institute of Biochemistry and Cellular Biology – National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy; (G.P.C.); (C.G.); (J.R.)
- Correspondence: (G.M.); (F.F.); Tel.: +39-081-613-2296 (G.M.); +39-081-613-2611 (F.F.)
| | - Amelia Cimmino
- Institute of Genetics and Biophysics “Adriano Buzzati Traverso”–National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy; (S.T.); (A.C.)
| | - Ferdinando Febbraio
- Institute of Biochemistry and Cellular Biology – National Research Council (CNR), via Pietro Castellino 111, 80131 Naples, Italy; (G.P.C.); (C.G.); (J.R.)
- Correspondence: (G.M.); (F.F.); Tel.: +39-081-613-2296 (G.M.); +39-081-613-2611 (F.F.)
| |
Collapse
|
4
|
Sanganalmath PU, Nagaraju PM, Sreeramulu K. Determination of quinalphos in human whole blood samples by high-performance thin-layer chromatography for forensic applications. J Chromatogr A 2019; 1594:181-189. [PMID: 30745138 DOI: 10.1016/j.chroma.2019.02.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 01/29/2019] [Accepted: 02/01/2019] [Indexed: 11/24/2022]
Abstract
A simple and rapid procedure for the determination of quinalphos in human whole blood using liquid-liquid extraction and high-performance thin-layer chromatography was developed and validated. Seven different organic solvents were tested for optimum extraction of quinalphos from spiked blood samples. The effect of pH on the extraction yield of quinalphos was also examined. An average recovery of 93.61% was achieved from diethyl ether solvent at pH 3. Chromatographic separation was performed on silica gel 60F254 plates using mobile phase n-hexane-acetone in the ration 9:1 (v/v). Densitometric detection was carried out at 325 nm in absorbance mode. The interference of other organophosphorus pesticides of forensic relevance was not observed. The linear regression analysis in spiked whole blood samples resulted in linear calibration plot in the range 1 to 100 μg mL-1 with r2 = 0.9981. Sensitivity was represented by LLOQ at 1 μg mL-1. The within-day precision and between-day precision ranged from 0.18 to 1.04%, and 0.14 to 0.79% with an overall average recovery of 91.06% at three concentrations 1, 10, and 50 μg mL-1. No significant decrease in the concentration of quinalphos was observed for samples under different storage conditions. Finally, the developed procedure was applied to postmortem blood samples obtained in three fatal cases of poisoning by quinalphos.
Collapse
Affiliation(s)
- Praveen U Sanganalmath
- Department of Biochemistry, Gulbarga University, Kalaburagi, 585 106, Karnataka, India; Toxicology Division, Regional Forensic Science Laboratory, Kalaburagi, 585 102, Karnataka, India
| | - Purigali M Nagaraju
- Toxicology Division, Regional Forensic Science Laboratory, Davanagere, 577 566, Karnataka, India
| | - Kuruba Sreeramulu
- Department of Biochemistry, Gulbarga University, Kalaburagi, 585 106, Karnataka, India.
| |
Collapse
|
5
|
Lee CW, Su H, Chen PY, Lin SJ, Shiea J, Shin SJ, Chen BH. Rapid identification of pesticides in human oral fluid for emergency management by thermal desorption electrospray ionization/mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2016; 51:97-104. [PMID: 26889925 DOI: 10.1002/jms.3719] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Revised: 10/15/2015] [Accepted: 10/19/2015] [Indexed: 06/05/2023]
Abstract
Self-poisoning with pesticides accounts for approximately one-third of all suicides worldwide. To expedite rescue in the emergency department, it is essential to develop a point-of-care analytical method for rapid identification of ingested pesticides. In this study, five of the most common pesticides ingested by self-poisoning patients in Taiwan were analyzed from oral fluid samples. Pesticide-oral fluid mixtures were applied on a cotton swab and then transferred into methanol. A metallic probe was used to sample the methanol solution for subsequent thermal desorption-electrospray ionization mass spectrometry analysis. Altogether, pesticide sampling, transfer, desorption, ionization, and detection took less than 1 min. The reproducibility of this method (n = 6) was shown in the observed low-relative standard deviation (<7%) in the detection of pesticide in oral fluid. The detection limits of the pesticides in oral fluid obtained from four human subjects by thermal desorption-electrospray ionization mass spectrometry were between 1-10 ppb with relative standard deviation 10.7%. Moreover, in this study, linear responses of five pesticides in oral fluid with concentrations between 1 ppb-1 ppm (R2 between 0.9938 and 0.9988) were observed. As the whole analytical process is extremely short, this technique allows for early non-invasive point-of-care identification of pesticides in the oral fluid of self-poisoning patients in the emergency room, providing important toxicological information for decision-making during critical resuscitation.
Collapse
Affiliation(s)
- Chi-Wei Lee
- Graduate Institute of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Emergency Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Hung Su
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Peng-Yu Chen
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Shiang-Jiun Lin
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Jentaie Shiea
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Shyi-Jang Shin
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Bai-Hsiun Chen
- Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| |
Collapse
|
6
|
Rhee J, Cho B, Lee J, Moon S, Yum H. Liquid chromatography with tandem mass spectrometry for the determination of flufenoxuron in blood using automatic solid phase extraction and its application to a fatal case of flufenoxuron poisoning. Forensic Sci Int 2015; 257:49-53. [DOI: 10.1016/j.forsciint.2015.07.041] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2015] [Revised: 07/12/2015] [Accepted: 07/26/2015] [Indexed: 11/28/2022]
|
7
|
Compound identification in forensic toxicological analysis with untargeted LC-MS-based techniques. Bioanalysis 2015; 7:2825-40. [PMID: 26563687 DOI: 10.4155/bio.15.193] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
Untargeted LC-MS/MS techniques have become indispensable tools for systematic toxicological analysis. Compound identification is based on the mass spectrometric information obtained, and this may include m/z, isotopic pattern, retention time and fragmentation information. All these different kinds of analytical features can be stored in libraries and databases. Currently, the most competent approach for compound identification involves tandem mass spectral library search. State-of-the-art databases were shown to be sensitive, specific, robust and instrument-independent. Low- and high-resolution instruments can both be used to develop efficient screening workflows. For automated and unattended acquisition of tandem mass spectral data, data-dependent acquisition control is the method of choice. Due to their impressive detection sensitivity, data-independent acquisition techniques are finding increased applicability.
Collapse
|
8
|
Kim HS, Kim J, Suh JH, Han SB. General unknown screening for pesticides in whole blood and Korean gastric contents by liquid chromatography–tandem mass spectrometry. Arch Pharm Res 2014; 37:1317-24. [DOI: 10.1007/s12272-014-0440-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Accepted: 06/28/2014] [Indexed: 11/28/2022]
|
9
|
Meyer GMJ, Weber AA, Maurer HH. Development and validation of a fast and simple multi-analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC-MS and one-point calibration. Drug Test Anal 2013; 6:472-81. [DOI: 10.1002/dta.1555] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 08/27/2013] [Accepted: 08/27/2013] [Indexed: 11/11/2022]
Affiliation(s)
- Golo M. J. Meyer
- Department of Experimental and Clinical Toxicology; Institute of Experimental and Clinical, Pharmacology and Toxicology, Saarland University; D-66421; Homburg (Saar); Germany
| | - Armin A. Weber
- Department of Experimental and Clinical Toxicology; Institute of Experimental and Clinical, Pharmacology and Toxicology, Saarland University; D-66421; Homburg (Saar); Germany
| | - Hans H. Maurer
- Department of Experimental and Clinical Toxicology; Institute of Experimental and Clinical, Pharmacology and Toxicology, Saarland University; D-66421; Homburg (Saar); Germany
| |
Collapse
|
10
|
Chen X, Xu L, Ma W, Liu L, Kuang H, Wang L, Xu C. General immunoassay for pyrethroids based on a monoclonal antibody. FOOD AGR IMMUNOL 2013. [DOI: 10.1080/09540105.2013.794328] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
11
|
What is the future of (ultra) high performance liquid chromatography coupled to low and high resolution mass spectrometry for toxicological drug screening? J Chromatogr A 2013; 1292:19-24. [DOI: 10.1016/j.chroma.2012.08.069] [Citation(s) in RCA: 81] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 08/16/2012] [Accepted: 08/22/2012] [Indexed: 12/12/2022]
|
12
|
Oberacher H, Schubert B, Libiseller K, Schweissgut A. Detection and identification of drugs and toxicants in human body fluids by liquid chromatography-tandem mass spectrometry under data-dependent acquisition control and automated database search. Anal Chim Acta 2013; 770:121-31. [PMID: 23498694 DOI: 10.1016/j.aca.2013.01.057] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2012] [Revised: 01/29/2013] [Accepted: 01/31/2013] [Indexed: 11/19/2022]
Abstract
Systematic toxicological analysis (STA) is aimed at detecting and identifying all substances of toxicological relevance (i.e. drugs, drugs of abuse, poisons and/or their metabolites) in biological material. Particularly, gas chromatography-mass spectrometry (GC/MS) represents a competent and commonly applied screening and confirmation tool. Herein, we present an untargeted liquid chromatography-tandem mass spectrometry (LC/MS/MS) assay aimed to complement existing GC/MS screening for the detection and identification of drugs in blood, plasma and urine samples. Solid-phase extraction was accomplished on mixed-mode cartridges. LC was based on gradient elution in a miniaturized C18 column. High resolution electrospray ionization-MS/MS in positive ion mode with data-dependent acquisition control was used to generate tandem mass spectral information that enabled compound identification via automated library search in the "Wiley Registry of Tandem Mass Spectral Data, MSforID". Fitness of the developed LC/MS/MS method for application in STA in terms of selectivity, detection capability and reliability of identification (sensitivity/specificity) was demonstrated with blank samples, certified reference materials, proficiency test samples, and authentic casework samples.
Collapse
Affiliation(s)
- Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Innsbruck, Austria.
| | | | | | | |
Collapse
|
13
|
Maurer HH. How Can Analytical Diagnostics in Clinical Toxicology Be Successfully Performed Today? Ther Drug Monit 2012. [DOI: 10.1097/ftd.0b013e31826a622d.] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
14
|
Abstract
This article discusses current strategies for efficient analytical diagnostics in clinical toxicology. The tasks for such diagnostics, different analytical strategies and various methods were reviewed. They cover mainly gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry procedures for target or comprehensive screening for drugs (of abuse) and poisons, and for quantification in blood. Quality control aspects and strategies for competent interpretation of the analytical result in correlation with the clinical signs presented by the patient are discussed.
Collapse
|
15
|
Zhang K, Wong JW, Yang P, Hayward DG, Sakuma T, Zou Y, Schreiber A, Borton C, Nguyen TV, Kaushik B, Oulkar D. Protocol for an electrospray ionization tandem mass spectral product ion library: development and application for identification of 240 pesticides in foods. Anal Chem 2012; 84:5677-84. [PMID: 22686274 DOI: 10.1021/ac300844d] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Modern determination techniques for pesticides must yield identification quickly with high confidence for timely enforcement of tolerances. A protocol for the collection of liquid chromatography (LC) electrospray ionization (ESI)-quadruple linear ion trap (Q-LIT) mass spectrometry (MS) library spectra was developed. Following the protocol, an enhanced product ion (EPI) library of 240 pesticides was developed by use of spectra collected from two laboratories. A LC-Q-LIT-MS workflow using scheduled multiple reaction monitoring (sMRM) survey scan, information-dependent acquisition (IDA) triggered collection of EPI spectra, and library search was developed and tested to identify the 240 target pesticides in one single LC-Q-LIT MS analysis. By use of LC retention time, one sMRM survey scan transition, and a library search, 75-87% of the 240 pesticides were identified in a single LC/MS analysis at fortified concentrations of 10 ng/g in 18 different foods. A conventional approach with LC-MS/MS using two MRM transitions produced the same identifications and comparable quantitative results with the same incurred foods as the LC-Q-LIT using EPI library search, finding 1.2-49 ng/g of either carbaryl, carbendazim, fenbuconazole, propiconazole, or pyridaben in peaches; carbendazim, imazalil, terbutryn, and thiabendazole in oranges; terbutryn in salmon; and azoxystrobin in ginseng. Incurred broccoli, cabbage, and kale were screened with the same EPI library using three LC-Q-LIT and a LC-quadruple time-of-flight (Q-TOF) instruments. The library search identified azoxystrobin, cyprodinil, fludioxinil, imidacloprid, metalaxyl, spinosyn A, D, and J, amd spirotetramat with each instrument. The approach has a broad application in LC-MS/MS type targeted screening in food analysis.
Collapse
Affiliation(s)
- Kai Zhang
- Office of Regulatory Science, Center for Food Safety and Applied Nutrition, US Food and Drug Administration, College Park, Maryland 20740, United States.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Xiao JF, Zhou B, Ressom HW. Metabolite identification and quantitation in LC-MS/MS-based metabolomics. Trends Analyt Chem 2012; 32:1-14. [PMID: 22345829 PMCID: PMC3278153 DOI: 10.1016/j.trac.2011.08.009] [Citation(s) in RCA: 331] [Impact Index Per Article: 27.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Metabolomics aims at detection and quantitation of all metabolites in biological samples. The presence of metabolites with a wide variety of physicochemical properties and different levels of abundance challenges existing analytical platforms used for identification and quantitation of metabolites. Significant efforts have been made to improve analytical and computational methods for metabolomics studies.This review focuses on the use of liquid chromatography with tandem mass spectrometry (LC-MS/MS) for quantitative and qualitative metabolomics studies. It illustrates recent developments in computational methods for metabolite identification, including ion annotation, spectral interpretation and spectral matching. We also review selected reaction monitoring and high-resolution MS for metabolite quantitation. We discuss current challenges in metabolite identification and quantitation as well as potential solutions.
Collapse
Affiliation(s)
| | | | - Habtom W. Ressom
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University, 4000 Reservoir Rd., NW, Washington DC, 20057
| |
Collapse
|
17
|
Marquet P. LC-MS vs. GC-MS, online extraction systems, advantages of technology for drug screening assays. Methods Mol Biol 2012; 902:15-27. [PMID: 22767104 DOI: 10.1007/978-1-61779-934-1_2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This chapter reviews recent applications of mass spectrometry to systematic toxicological analysis (STA), where extended lists of compounds of toxicological interest are screened, as well as to the general unknown screening (GUS), where all exogenous compounds present in a sample are tentatively detected and identified, without any preselection. Many recent improvements in sample preparation, chromatographic separation, gas chromatography-mass spectrometry, and above all liquid chromatography-mass spectrometry techniques are described, which are applicable or have been applied to STA and/or GUS, generally with promising results. These improvements come from miniaturization and automation of solid-phase extraction, turbulent-flow or ultrahigh-pressure liquid chromatography, linear ion traps, accurate (e.g., time of flight or orbital trap) mass spectrometry, as well as software refinements to alternate between different ionization modes or automatically interpret the results. It also shows that robust LC-MS/MS techniques already exist for STA or GUS, which are at least as efficient as the traditional techniques used in most toxicology laboratories, such as GC-MS or high-performance liquid chromatography with diode-array detection, as shown by three comparative studies. However, the major drawback of LC-MS/MS in the full-scan mode for STA or GUS is that it still lacks universal reference libraries due to insufficient reproducibility of LC-MS(/MS) mass spectra obtained with different instrument types.
Collapse
Affiliation(s)
- Pierre Marquet
- Department of Pharmacology-Toxicology-Pharmacovigilance, Centre Hospitalier Universitaire (CHU) de Limoges, Limoges, France.
| |
Collapse
|
18
|
Wissenbach DK, Meyer MR, Weber AA, Remane D, Ewald AH, Peters FT, Maurer HH. Towards a universal LC-MS screening procedure - can an LIT LC-MS(n) screening approach and reference library be used on a quadrupole-LIT hybrid instrument? JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:66-71. [PMID: 22282091 DOI: 10.1002/jms.2027] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
In contrast to libraries with highly reproducible gas chromatography electron ionization mass spectra, current liquid chromatography (LC-MS) libraries are limited to specific instrument types. Therefore, the aim of the study was to prove whether a recently developed linear ion trap (LIT) LC-MS(n) screening approach and reference library can be transferred to an LC-MS/MS system with a quadrupole-LIT hybrid mass analyzer using SmileMS, a sophisticated search algorithm. The LIT reference library was built with MS² and MS³ wideband spectra recorded on a ThermoFisher LXQ LIT with electrospray ionization in positive mode and full-scan data-dependent acquisition (DDA). Collision parameter optimizations, including different scan types and energies, were performed on an Applied Biosystems QTRAP 4000 system using electrospray ionization in positive mode and full-scan DDA. Modified library sets were generated to improve the detection of a compound by the used search algorithm. Additionally, 100 authentic human urine samples were screened by both systems for proof of applicability. In the applicability study, 533 compounds were detected by the LXQ and 477 by the QTRAP system using enhanced product ion scan and a modified database. The presented data showed that the LIT screening approach and reference library could be used successfully on a QTRAP instrument with some limitations. These should be overcome by further optimizations regarding DDA settings for better sensitivity and further library modifications to reduce spectra mismatches.
Collapse
Affiliation(s)
- Dirk K Wissenbach
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, D-66421, Homburg, Saar, Germany
| | | | | | | | | | | | | |
Collapse
|
19
|
Milman BL, Zhurkovich IK. Towards a full reference library of MS(n) spectra. II: A perspective from the library of pesticide spectra extracted from the literature/Internet. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:3697-3705. [PMID: 22468332 DOI: 10.1002/rcm.5279] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
To gain perspective on building full transferable libraries of MS(n) spectra from their diverse/numerous collections, a new library was built from 1723 MS(>1) spectra (mainly MS² spectra) of 490 pesticides and related compounds. Spectra acquired on different types of tandem instruments in various experimental conditions were extracted from 168 literature articles and Internet sites. Testing of the library was based on searches where 'unknown' and reference spectra originated from different sources (mainly from different laboratories) were cross-compared. The NIST 05 MS² library was added to the reference spectra. The library searches were performed with all the test spectra or were divided into different subsamples containing (a) various numbers of replicate spectra of test compounds or (b) spectra acquired from different instrument types. Thus, the dependence of true/false search (identification) result rates on different factors was explored. The percentage of 1st rank correct identifications (true positives) for the only 'unknown' mass spectrum and two and more reference spectra and matching precursor ion m/z values was 89%. For qualified matches, above the cut-off match factor, that rate decreased to 80%. The corresponding rates based on the best match for two and more 'unknown' and reference spectral replicates were 89-94%. For quadrupole instruments, the rates were even higher: 91-95% (one 'unknown' spectrum) and 90-100% (two and more such spectra). This study shows that MS² spectral libraries generated from the numerous literature/Internet sources are not less efficient for the goal of identification of unknown compounds including pesticides than very common EI-MS¹ libraries and are almost as efficient as the most productive from current MS² spectral databases. Such libraries may be used as individual reference databases or supplements to large experimental spectral collections covering many groups of abundant compounds and different types of tandem mass spectrometers.
Collapse
Affiliation(s)
- Boris L Milman
- D.I. Mendeleyev Institute for Metrology, Saint Petersburg, Russia.
| | | |
Collapse
|
20
|
Niessen WMA. Fragmentation of toxicologically relevant drugs in positive-ion liquid chromatography-tandem mass spectrometry. MASS SPECTROMETRY REVIEWS 2011; 30:626-663. [PMID: 21294151 DOI: 10.1002/mas.20332] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2010] [Revised: 01/05/2011] [Accepted: 01/05/2011] [Indexed: 05/30/2023]
Abstract
The identification of drugs and related compounds by LC-MS-MS is an important analytical challenge in several application areas, including clinical and forensic toxicology, doping control analysis, and environmental analysis. Although target-compound based analytical strategies are most frequently applied, at some point the information content of the MS-MS spectra becomes relevant. In this article, the positive-ion MS-MS spectra of a wide variety of drugs and related substances are discussed. Starting point was an MS-MS mass spectral library of toxicologically relevant compounds, available on the internet. The positive-ion MS-MS spectra of ∼570 compounds were interpreted by chemical and therapeutic class, thus involving a wide variety of drug compound classes, such benzodiazepines, beta-blockers, angiotensin-converting enzyme inhibitors, phenothiazines, dihydropyridine calcium channel blockers, diuretics, local anesthetics, vasodilators, as well as various subclasses of anti-diabetic, antidepressant, analgesic, and antihistaminic drugs. In addition, the scientific literature was searched for available MS-MS data of these compound classes and the interpretation thereof. The results of this elaborate study are presented in this article. For each individual compound class, the emphasis is on class-specific fragmentation, as discussing fragmentation of all individual compounds would take far too much space. The recognition of class-specific fragmentation may be quite informative in determining the compound class of a specific unknown, which may further help in the identification. In addition, knowledge on (class-specific) fragmentation may further help in the optimization of the selectivity in targeted analytical approaches of compounds of one particular class.
Collapse
|
21
|
Drugs of abuse screening in urine as part of a metabolite-based LC-MSn screening concept. Anal Bioanal Chem 2011; 400:3481-9. [DOI: 10.1007/s00216-011-5032-1] [Citation(s) in RCA: 115] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2011] [Revised: 04/11/2011] [Accepted: 04/15/2011] [Indexed: 10/18/2022]
|
22
|
Wang M, Quist HE, Hansen BJ, Peng Y, Zhang Z, Hawkins AR, Rockwood AL, Austin DE, Lee ML. Performance of a halo ion trap mass analyzer with exit slits for axial ejection. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:369-378. [PMID: 21472596 DOI: 10.1007/s13361-010-0027-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2010] [Revised: 10/27/2010] [Accepted: 11/05/2010] [Indexed: 05/30/2023]
Abstract
The halo ion trap (IT) was modified to allow for axial ion ejection through slits machined in the ceramic electrode plates rather than ejecting ions radially to a center hole in the plates. This was done to preserve a more uniform electric field for ion analysis. An in-depth evaluation of the higher-order electric field components in the trap was also performed to improve resolution. The linear, cubic and quintic (5th order) electric field components for each electrode ring inside the IT were calculated using SIMION (SIMION version 8, Scientific Instrument Services, Ringoes, NJ, USA) simulations. The preferred electric fields with higher-order components were implemented experimentally by first calculating the potential on each electrode ring of the halo IT and then soldering appropriate capacitors between rings without changing the original trapping plate design. The performance of the halo IT was evaluated for 1% to 7% cubic electric field (A (4)/A (2)) component. A best resolution of 280 (m/Δm) for the 51-Da fragment ion of benzene was observed with 5% cubic electric field component. Confirming results were obtained using toluene, dichloromethane, and heptane as test analytes.
Collapse
Affiliation(s)
- Miao Wang
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Recent advances of liquid chromatography–(tandem) mass spectrometry in clinical and forensic toxicology. Clin Biochem 2011; 44:54-65. [DOI: 10.1016/j.clinbiochem.2010.08.008] [Citation(s) in RCA: 157] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2010] [Revised: 08/04/2010] [Accepted: 08/05/2010] [Indexed: 11/23/2022]
|
24
|
Mueller DM, Duretz B, Espourteille FA, Rentsch KM. Development of a fully automated toxicological LC-MSn screening system in urine using online extraction with turbulent flow chromatography. Anal Bioanal Chem 2010; 400:89-100. [DOI: 10.1007/s00216-010-4560-4] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2010] [Revised: 11/24/2010] [Accepted: 12/01/2010] [Indexed: 10/18/2022]
|
25
|
Development of the first metabolite-based LC-MS n urine drug screening procedure-exemplified for antidepressants. Anal Bioanal Chem 2010; 400:79-88. [DOI: 10.1007/s00216-010-4398-9] [Citation(s) in RCA: 89] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Revised: 10/21/2010] [Accepted: 10/26/2010] [Indexed: 10/18/2022]
|