1
|
Jiang T, Bai X, Li M. Advances in the Development of Bacterial Bioluminescence Imaging. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2024; 17:265-288. [PMID: 38640069 DOI: 10.1146/annurev-anchem-061622-034229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/21/2024]
Abstract
Bioluminescence imaging (BLI) is a powerful method for visualizing biological processes and tracking cells. Engineered bioluminescent bacteria that utilize luciferase-catalyzed biochemical reactions to generate luminescence have become useful analytical tools for in vitro and in vivo bacterial imaging. Accordingly, this review initially introduces the development of engineered bioluminescent bacteria that use different luciferase-luciferin pairs as analytical tools and their applications for in vivo BLI, including real-time bacterial tracking of infection, probiotic investigation, tumor-targeted therapy, and drug screening. Applications of engineered bioluminescent bacteria as whole-cell biosensors for sensing biological changes in vitro and in vivo are then discussed. Finally, we review the optimizations and future directions of bioluminescent bacteria for imaging. This review aims to provide fundamental insights into bacterial BLI and highlight the potential development of this technique in the future.
Collapse
Affiliation(s)
- Tianyu Jiang
- 1Helmholtz International Lab for Anti-Infectives, State Key Laboratory of Microbial Technology, Institute of Microbial Technology, Shandong University, Qingdao, Shandong, China
| | - Xiaoyu Bai
- 1Helmholtz International Lab for Anti-Infectives, State Key Laboratory of Microbial Technology, Institute of Microbial Technology, Shandong University, Qingdao, Shandong, China
- 2School of Life Sciences, Shandong University, Qingdao, Shandong, China
| | - Minyong Li
- 3Key Laboratory of Chemical Biology (MOE), Department of Medicinal Chemistry, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China;
| |
Collapse
|
2
|
Zhang X, Zhu Y, Elçin E, He L, Li B, Jiang M, Yang X, Yan XP, Zhao X, Wang Z, Wang F, Shaheen SM, Rinklebe J, Wells M. Whole-cell bioreporter application for rapid evaluation of hazardous metal bioavailability and toxicity in bioprocess. JOURNAL OF HAZARDOUS MATERIALS 2024; 461:132556. [PMID: 37757563 DOI: 10.1016/j.jhazmat.2023.132556] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 09/03/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023]
Abstract
Assessing heavy metal bioavailability and toxicity during bioprocess is critical for advancing green biotechnology. The capability of whole-cell bioreporters to measure heavy metal bioavailability has been increasingly recognized. The advantages of this technology being applied to bioprocess monitoring are less studied. Here we investigate the potential of a cadmium- and lead-sensitive bioreporter to be used for heavy metals as a class, which holds great interest for bioprocess applications. We evaluated the bioavailability of eight individual heavy metals with bioreporter zntA, as well as the bioavailability and toxicity of mixed metals. The bioavailability and toxicity of heavy metals in bioprocess samples were also evaluated. We have demonstrated for the first time that the zntA bioreporter can effectively detect the bioavailability of zinc, nickel, and cobalt with limit of detection lower than 0.01, 0.08 and 0.5 mg·L-1, respectively. The detection limits meet the requirements of the WHO, the U.S. Environmental Protection Agency, and the China drinking water quality standards, which makes this approach reasonable for monitoring heavy metal bioavailability in bioprocess. LIVE/DEAD toxicity experiments have been conducted for the detection of mixed metal solution toxicity to zntA bioreporter which shows an EC50 (as EC50, concentration for 50% of maximal effect) value of mixed metal solution is 3.84 mg·L-1. Samples from wastewater treatment plants, sludge treatment plants and kitchen waste fermentation processes were analyzed to extend upon the laboratory results. The results of this study confirm the potential for practical applications of bioreporter technology in bioprocess monitoring. In turn, development for such practical applications is key to achieve the necessary level of commercialization to further make the routine use of bioreporters in bioprocess monitoring feasible.
Collapse
Affiliation(s)
- Xiaokai Zhang
- Institute of Environmental Processes and Pollution Control, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China
| | - Yi Zhu
- Institute of Environmental Processes and Pollution Control, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China
| | - Evrim Elçin
- Department of Agricultural Biotechnology, Division of Enzyme and Microbial Biotechnology, Faculty of Agriculture, Aydın Adnan Menderes University, Aydın 09970, Turkey
| | - Lizhi He
- Key Laboratory of Soil Contamination Bioremediation of Zhejiang Province, Zhejiang A & F University, Lin'an 311300, China
| | - Boling Li
- School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Mengyuan Jiang
- Institute of Environmental Processes and Pollution Control, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China
| | - Xing Yang
- Key Laboratory of Agro-Forestry Environmental Processes and Ecological Regulation of Hainan Province, School of Ecology and Environment, Hainan University, Haikou 570228, China
| | - Xiu-Ping Yan
- School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xu Zhao
- School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Zhenyu Wang
- Institute of Environmental Processes and Pollution Control, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China; Jiangsu Collaborative Innovation Center of Technology and Material of Water Treatment, Suzhou University of Science and Technology, Suzhou 215009, China.
| | - Fang Wang
- CAS Key Laboratory of Soil Environment and Pollution Remediation, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008, China
| | - Sabry M Shaheen
- University of Wuppertal, School of Architecture and Civil Engineering, Institute of Foundation Engineering, Water, andWaste-Management, Laboratory of Soil, and Groundwater-Management, Pauluskirchstraße 7, 42285 Wuppertal, Germany; King Abdulaziz University, Faculty of Meteorology, Environment, and Arid Land Agriculture, Department of Arid Land Agriculture, 21589 Jeddah, Saudi Arabia; University of Kafrelsheikh, Faculty of Agriculture, Department of Soil and Water Sciences, 33516, Kafr El-Sheikh, Egypt
| | - Jörg Rinklebe
- University of Wuppertal, School of Architecture and Civil Engineering, Institute of Foundation Engineering, Water, andWaste-Management, Laboratory of Soil, and Groundwater-Management, Pauluskirchstraße 7, 42285 Wuppertal, Germany
| | - Mona Wells
- The Meadows Center for Water and the Environment, Texas State University, San Marcos, TX 78666, USA; Natural Sciences, Ronin Institute, Montclair, New Jersey 07043, USA
| |
Collapse
|
3
|
Abilev SK, Igonina EV, Sviridova DA, Smirnova SV. Bacterial Lux Biosensors in Genotoxicological Studies. BIOSENSORS 2023; 13:bios13050511. [PMID: 37232872 DOI: 10.3390/bios13050511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/18/2023] [Accepted: 04/20/2023] [Indexed: 05/27/2023]
Abstract
The aim of this study was to assess the applicability of the bacterial lux biosensors for genotoxicological studies. Biosensors are the strains of E. coli MG1655 carrying a recombinant plasmid with the lux operon of the luminescent bacterium P. luminescens fused with the promoters of inducible genes: recA, colD, alkA, soxS, and katG. The genotoxicity of forty-seven chemical compounds was tested on a set of three biosensors pSoxS-lux, pKatG-lux and pColD-lux, which allowed us to estimate the oxidative and DNA-damaging activity of the analyzed drugs. The comparison of the results with the data on the mutagenic activity of these drugs from the Ames test showed a complete coincidence of the results for the 42 substances. First, using lux biosensors, we have described the enhancing effect of the heavy non-radioactive isotope of hydrogen deuterium (D2O) on the genotoxicity of chemical compounds as possible mechanisms of this effect. The study of the modifying effect of 29 antioxidants and radioprotectors on the genotoxic effects of chemical agents showed the applicability of a pair of biosensors pSoxS-lux and pKatG-lux for the primary assessment of the potential antioxidant and radioprotective activity of chemical compounds. Thus, the results obtained showed that lux biosensors can be successfully used to identify potential genotoxicants, radioprotectors, antioxidants, and comutagens among chemical compounds, as well as to study the probable mechanism of genotoxic action of test substance.
Collapse
Affiliation(s)
- Serikbai K Abilev
- The Laboratory of Ecological Genetics, Vavilov Institute of General Genetics, Russian Academy of Sciences, Moscow 117971, Russia
| | - Elena V Igonina
- The Laboratory of Ecological Genetics, Vavilov Institute of General Genetics, Russian Academy of Sciences, Moscow 117971, Russia
| | - Darya A Sviridova
- The Laboratory of Ecological Genetics, Vavilov Institute of General Genetics, Russian Academy of Sciences, Moscow 117971, Russia
| | - Svetlana V Smirnova
- The Laboratory of Ecological Genetics, Vavilov Institute of General Genetics, Russian Academy of Sciences, Moscow 117971, Russia
| |
Collapse
|
4
|
Zou ZP, Yang Y, Wang J, Zhou Y, Ye BC. Coupling split-lux cassette with a toggle switch in bacteria for ultrasensitive blood markers detection in feces and urine. Biosens Bioelectron 2022; 214:114520. [DOI: 10.1016/j.bios.2022.114520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 06/24/2022] [Accepted: 06/26/2022] [Indexed: 11/29/2022]
|
5
|
Yang J, Hu S, Wu M, Liao A, Liang S, Lin Y. Construction of luminescent Escherichia coli via expressing lux operons and their application on toxicity test. Appl Microbiol Biotechnol 2022; 106:6317-6333. [PMID: 36028635 DOI: 10.1007/s00253-022-12136-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 08/08/2022] [Accepted: 08/16/2022] [Indexed: 12/01/2022]
Abstract
Recombinant luminescent Escherichia coli strains could be used to detect the toxicity of pure or mixed contaminants as a light-off sensor. In this work, the lux operon of Photobacterium phosphoreum T3 was identified for the first time. Recombinant luminescent E. coli strains were constructed via expressing the lux operons of P. phosphoreum T3 and Vibrio qinghaiensis Q67 in E. coli MG1655, and the optimal protectant containing 10% (w/v) trehalose and 4% sucrose was used to prepare the freeze-dried recombinant luminescent E. coli cells. Then, these freeze-dried E. coli cells were subjected to acute toxicity detection. The results showed that luminescent E. coli strains displayed sensitive toxic responses to BPA, nFe2O3, Cd, Pb, As, and Hg, for example, the EC50 values of BPA and nFe2O3 to luminescent E. coli strains ranged from 1.54 to 50.19 mg/l and 17.50 to 21.52 mg/l, respectively. Indeed, luminescent E. coli strains exhibited more sensitive responses to Cd, Pb, and Hg than the natural strain Q67. The results suggested that recombinant luminescent E. coli strains could be used for the detection of acute toxicity. Furthermore, the combined toxicities of BPA and nFe2O3, Hg, and Pb were measured, and the joint effects of these mixtures were evaluated with luminescent E. coli. The results indicated that the joint effects of BPA and nFe2O3 suggested to be synergistic or additive to luminescent E. coli, while the joint effects of heavy metals and nFe2O3 exhibited additivities. The cellular endocytosis for Fe2O3 nanoparticles was not observed, which could explain the additive instead of synergistic effects between heavy metals and nFe2O3. KEY POINTS: • Sequence of the lux operon from P. phosphoreum T3 was reported for the first time. • Recombinant luminescent E. coli was more sensitive to Cd, Pb, and Hg than Q67. • Joint effects of BPA and nFe2O3 were synergistic or additive to luminescent E. coli.
Collapse
Affiliation(s)
- Jun Yang
- School of Biology and Biological Engineering, South China University of Technology, Higher Education Mega Center, Guangzhou, 510006, China.,Guangdong Provincial Key Laboratory of Fermentation and Enzyme Engineering, South China University of Technology, Guangzhou, 510006, China
| | - Shulin Hu
- School of Biology and Biological Engineering, South China University of Technology, Higher Education Mega Center, Guangzhou, 510006, China.,Guangdong Provincial Key Laboratory of Fermentation and Enzyme Engineering, South China University of Technology, Guangzhou, 510006, China
| | - Minhui Wu
- School of Biology and Biological Engineering, South China University of Technology, Higher Education Mega Center, Guangzhou, 510006, China.,Guangdong Provincial Key Laboratory of Fermentation and Enzyme Engineering, South China University of Technology, Guangzhou, 510006, China
| | - Anqi Liao
- School of Biology and Biological Engineering, South China University of Technology, Higher Education Mega Center, Guangzhou, 510006, China.,Guangdong Provincial Key Laboratory of Fermentation and Enzyme Engineering, South China University of Technology, Guangzhou, 510006, China
| | - Shuli Liang
- School of Biology and Biological Engineering, South China University of Technology, Higher Education Mega Center, Guangzhou, 510006, China.,Guangdong Provincial Key Laboratory of Fermentation and Enzyme Engineering, South China University of Technology, Guangzhou, 510006, China
| | - Ying Lin
- School of Biology and Biological Engineering, South China University of Technology, Higher Education Mega Center, Guangzhou, 510006, China. .,Guangdong Provincial Key Laboratory of Fermentation and Enzyme Engineering, South China University of Technology, Guangzhou, 510006, China.
| |
Collapse
|
6
|
Bacterial bioluminescence assay for bioanalysis and bioimaging. Anal Bioanal Chem 2021; 414:75-83. [PMID: 34693470 DOI: 10.1007/s00216-021-03695-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 08/31/2021] [Accepted: 09/24/2021] [Indexed: 10/20/2022]
Abstract
Bioluminescence occurs through a chemical reaction in organisms that spontaneously produce light. Luminescent bacteria are unique among bioluminescent organisms. Their bioluminescence intensity is an indicator of their metabolic activity, which can directly reflect the influence of environmental factors on cell viability. Moreover, the whole bioluminescence process is totally gene encoded without the addition of extra substrates. As a result, bacterial bioluminescence has been a powerful tool for whole-cell biosensors and bio-reporters in bioanalysis and bioimaging. This review aims to cover the applications of wild-type and recombinant luminescent bacteria to detect the toxicity of environmental pollutants and biological molecules. The bacterial bioluminescence analytical assay has characteristics such as high sensitivity, short-term detection, and easy operation. Meanwhile, due to the development of gene engineering and optical technology, bacterial luciferase as a reporter protein has been successfully expressed in prokaryotic and eukaryotic cells, tissues, and organs of animals. The major applications for bacterial luciferase-based bioluminescence imaging, such as infectious diseases, cancer therapy, and stem cell tracing, are discussed in this review.
Collapse
|
7
|
Abstract
Bacterial luciferase is a flavin-dependent monooxygenase which is remarkable for its distinctive feature in transforming chemical energy to photons of visible light. The bacterial luciferase catalyzes bioluminescent reaction using reduced flavin mononucleotide, long-chain aldehyde and oxygen to yield oxidized flavin, corresponding acid, water and light at λmax around 490nm. The enzyme comprises of two non-identical α and β subunits, where α subunit is a catalytic center and β subunit is crucially required for maintaining catalytic function of the α subunit. The crystal structure with FMN bound and mutagenesis studies have assigned a number of amino acid residues that are important in coordinating critical reactions and stabilizing intermediates to attain optimum reaction efficiency. The enzyme achieves monooxygenation by generating C4a-hydroperoxyflavin intermediate that later changes its protonation status to become C4a-peroxyflavin, which is necessary for the nucleophilic attacking with aldehyde substrate. The decomposing of C4a-peroxyhemiacetal produces excited C4a-hydroxyflavin and acid product. The chemical basis regrading bioluminophore generation in Lux reaction remains an inconclusive issue. However, current data can, at least, demonstrate the involvement of electron transfer to create radical molecules which is the key step in this mechanism. Lux is a self-sufficient bioluminescent system in which all substrates can be recycled and produced by a group of enzymes from the lux operon. This makes Lux distinctively advantageous over other luciferases for reporter enzyme application. The progression of understanding of Lux catalysis is beneficial to improve light emitting efficiency in order to expand the robustness of Lux application.
Collapse
|
8
|
Ma J, Veltman B, Tietel Z, Tsror L, Liu Y, Eltzov E. Monitoring of infection volatile markers using CMOS-based luminescent bioreporters. Talanta 2020; 219:121333. [PMID: 32887066 DOI: 10.1016/j.talanta.2020.121333] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 06/16/2020] [Accepted: 06/23/2020] [Indexed: 11/28/2022]
Abstract
Over the past two decades, whole-cell biosensors (WCBs) have been widely used in the environmental field, with only few applications proposed for use in agricultural. This study describes the development and optimization of a WCB for the detection of volatile organic compounds (VOCs) that is produced specifically by infected potato tubers. First, the effect of calcium-alginate matrix formation (beads vs. tablets) on the membrane uniformity and sensing efficiency was evaluated. Then, important parameters in the immobilization process were examined for their effect on the sensitivity to the presence of VOCs. The highest sensitivity to the target VOC was obtained by 20 min polymerization of bacterial suspension with optical density of 0.2 at 600 nm, dissolved in low-viscosity sodium alginate (1.5% w/v) and exposure to VOC at 4 °C. After optimization, the lowest limit of detection for three infection-sourced VOCs (nonanal, 3-methyl-1-butanol, and 1-octen-3-ol) was 0.17-, 2.03-, and 2.09-mg/L, respectively, and the sensor sensitivity was improved by 8.9-, 3.1- and 2-fold, respectively. Then, the new optimized immobilization protocol was implemented for the CMOS-based application, which increased the sensor sensitivity to VOC by 3-fold during real-time measurement. This is the first step in creating a sensor for real-time monitoring of crop quality by identifying changes in VOC patterns.
Collapse
Affiliation(s)
- Junning Ma
- Department of Postharvest Science, Institute of Postharvest and Food Sciences, The Volcani Center, Agricultural Research Organization, Bet Dagan, 50250, Israel; Key Laboratory of Agro-products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing, China
| | - Boris Veltman
- Department of Postharvest Science, Institute of Postharvest and Food Sciences, The Volcani Center, Agricultural Research Organization, Bet Dagan, 50250, Israel; Institute of Biochemistry, Food Science and Nutrition, Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Rehovot, 76100, Israel
| | - Zipora Tietel
- Food Quality and Safety, Agricultural Research Organization, Gilat Research Center, MP Negev, Israel
| | - Leah Tsror
- Department of Plant Pathology, Institute of Plant Protection, Agricultural Research Organization, Gilat Research Center, Negev, Israel
| | - Yang Liu
- Key Laboratory of Agro-products Quality and Safety Control in Storage and Transport Process, Ministry of Agriculture and Rural Affairs, Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing, China
| | - Evgeni Eltzov
- Department of Postharvest Science, Institute of Postharvest and Food Sciences, The Volcani Center, Agricultural Research Organization, Bet Dagan, 50250, Israel; Agro-Nanotechnology Research Center, Agriculture Research Organization, The Volcani Center, Rishon LeZion, 7505101, Israel.
| |
Collapse
|
9
|
JIN XW, LI ZY, XU PP, ZHANG XY, REN NQ, Kurilenko VV, SUN K. Advances in Microfluidic Biosensors Based on Luminescent Bacteria. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61139-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
10
|
Matejczyk M, Świderski G, Świsłocka R, Rosochacki SJ, Lewandowski W. Seleno-l-methionine and l-ascorbic acid differentiate the biological activity of doxorubicin and its metal complexes as a new anticancer drugs candidate. J Trace Elem Med Biol 2018; 48:141-148. [PMID: 29773172 DOI: 10.1016/j.jtemb.2018.03.021] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 03/16/2018] [Accepted: 03/23/2018] [Indexed: 01/03/2023]
Abstract
The most important problems of anti-cancer therapy include the toxicity of the drugs applied to healthy cells and the multi-drug cells resistance to chemotherapeutics. One of the most commonly used anticancer drugs is doxorubicin (DOX) used to treat certain leukemias and non-Hodgkin's lymphomas, as well as bladder, breast, stomach, lung, ovarian, thyroid, multiple myeloma and other cancers. Preliminary studies showed that metal complex with DOX improve its cytostatic activity with changes in their molecular structure and distribution of electrons, resulting in a substantial change of its biological activity (including antitumor activity). Thus, there is a chance to receiving derivatives of DOX with low toxicity for the healthy body cells, thus increasing its therapeutic selectivity. In the present study we examined the influence of Mn, Mg, Fe, Co and Ni, seleno-l-methionine and vitamin C on biological activity of DOX in prokaryotic model - Escherichia coli RFM443, with plasmid transcriptional fusion of recA promoter and luxCDABE as a reporter gene. Cytotoxic potency of tested chemicals was calculated on the basis of the bacteria culture growth inhibition (GI%) values. Genotoxic properties were calculated on the basis of the fold increase (FI) of relative luminescence units (RLU) values compared to control. Obtained results showed that doxorubicin metal complexes particularly with Ni, Co and Fe increased the cyto- and genotoxic activities of DOX. Bacteria culture supplemented with SeMet and vitamin C differentiate the DOX and its metal complexes toxicity. It seems, that DOX-Ni, DOX-Fe and DOX-Co complexes could be potent cytostatic drug candidates. Moreover, we noticed different sensitivity of recA::luxCDABE for 3 h and 24 h cultures of bacteria strain. It suggests, that the potency of genetic construct reactivity- recA::luxCDABE in E. coli depends on the growth-phase of bacterial culture.
Collapse
Affiliation(s)
- Marzena Matejczyk
- Bialystok University of Technology, Faculty of Civil Engineering and Environmental Engineering, Division of Chemistry, Biology and Biotechnology, Wiejska 45E, 15-351, Bialystok, Poland.
| | - Grzegorz Świderski
- Bialystok University of Technology, Faculty of Civil Engineering and Environmental Engineering, Division of Chemistry, Biology and Biotechnology, Wiejska 45E, 15-351, Bialystok, Poland
| | - Renata Świsłocka
- Bialystok University of Technology, Faculty of Civil Engineering and Environmental Engineering, Division of Chemistry, Biology and Biotechnology, Wiejska 45E, 15-351, Bialystok, Poland
| | - Stanisław Józef Rosochacki
- Bialystok University of Technology, Faculty of Civil Engineering and Environmental Engineering, Division of Chemistry, Biology and Biotechnology, Wiejska 45E, 15-351, Bialystok, Poland
| | - Włodzimierz Lewandowski
- Bialystok University of Technology, Faculty of Civil Engineering and Environmental Engineering, Division of Chemistry, Biology and Biotechnology, Wiejska 45E, 15-351, Bialystok, Poland
| |
Collapse
|
11
|
Modulating the sensing properties of Escherichia coli-based bioreporters for cadmium and mercury. Appl Microbiol Biotechnol 2018; 102:4863-4872. [DOI: 10.1007/s00253-018-8960-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2018] [Revised: 03/20/2018] [Accepted: 03/21/2018] [Indexed: 10/17/2022]
|
12
|
Strongly enhanced bacterial bioluminescence with the ilux operon for single-cell imaging. Proc Natl Acad Sci U S A 2018; 115:962-967. [PMID: 29339494 PMCID: PMC5798359 DOI: 10.1073/pnas.1715946115] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The emission of light generated in a process referred to as bioluminescence can be used for imaging of living cells over long timespans without phototoxicity or bleaching. The amounts of light produced in the bioluminescence process are very low, and exogenous substrate molecules are often required. We improved the brightness of bacterial bioluminescence, a system that features the advantage that all of the required molecular components are genetically encoded within a single operon. Consequently, we have engineered an improved operon ilux, which enables long-term visualization of single bacterial cells while simultaneously providing information about cellular viability. Bioluminescence imaging of single cells is often complicated by the requirement of exogenous luciferins that can be poorly cell-permeable or produce high background signal. Bacterial bioluminescence is unique in that it uses reduced flavin mononucleotide as a luciferin, which is abundant in all cells, making this system purely genetically encodable by the lux operon. Unfortunately, the use of bacterial bioluminescence has been limited by its low brightness compared with other luciferases. Here, we report the generation of an improved lux operon named ilux with an approximately sevenfold increased brightness when expressed in Escherichia coli; ilux can be used to image single E. coli cells with enhanced spatiotemporal resolution over several days. In addition, since only metabolically active cells produce bioluminescent signal, we show that ilux can be used to observe the effect of different antibiotics on cell viability on the single-cell level.
Collapse
|
13
|
Martín-Betancor K, Durand MJ, Thouand G, Leganés F, Fernández-Piñas F, Rodea-Palomares I. Microplate freeze-dried cyanobacterial bioassay for fresh-waters environmental monitoring. CHEMOSPHERE 2017; 189:373-381. [PMID: 28946071 DOI: 10.1016/j.chemosphere.2017.09.030] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Revised: 09/04/2017] [Accepted: 09/07/2017] [Indexed: 06/07/2023]
Abstract
Microorganisms have been very useful in environmental monitoring due to their constant sensing of the surrounding environment, their easy maintenance and low cost. Some freeze-dried toxicity kits based on naturally bioluminescent bacteria are commercially available and commonly used to assess the toxicity of environmental samples such as Microtox (Aliivibrio fischeri) or ToxScreen (Photobacterium leiognathi), however, due to the marine origin of these bacteria, they could not be the most appropriate for fresh-waters monitoring. Cyanobacteria are one of the most representative microorganisms of aquatic environments, and are well suited for detecting contaminants in aqueous samples. This study presents the development and application of the first freeze-dried cyanobacterial bioassay for fresh-water contaminants detection. The effects of different cell growth phases, cryoprotectant solutions, freezing protocols, rehydration solutions and incubation conditions methods were evaluated and the best combination of these parameters for freeze-drying was selected. The study includes detailed characterization of sensitivity towards reference pollutants, as well as, comparison with the standard assays. Moreover, long-term viability and sensitivity were evaluated after 3 years of storage. Freeze-dried cyanobacteria showed, in general, higher sensitivity than the standard assays and viability of the cells remained after 3 years of storage. Finally, the validation of the bioassay using a wastewater sample was also evaluated. Freeze-drying of cyanobacteria in 96-well plates presents a simple, fast and multi-assay method for environmental monitoring.
Collapse
Affiliation(s)
- Keila Martín-Betancor
- Department of Biology, Facultad de Ciencias, Universidad Autónoma de Madrid, 28049, Madrid, Spain.
| | | | | | - Francisco Leganés
- Department of Biology, Facultad de Ciencias, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | | | - Ismael Rodea-Palomares
- Department of Biology, Facultad de Ciencias, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| |
Collapse
|
14
|
Reporter Gene Assays in Ecotoxicology. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2017; 157:135-157. [PMID: 27928578 DOI: 10.1007/10_2016_47] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The need for simple and rapid means for evaluating the potential toxic effects of environmental samples has prompted the development of reporter gene assays, based on tester cells (bioreporters) genetically engineered to report on sample toxicity by producing a readily quantifiable signal. Bacteria are especially suitable to serve as bioreporters owing to their fast responses, low cost, convenient preservation, ease of handling, and amenability to genetic manipulations. Various bacterial bioreporters have been introduced for general toxicity and genotoxicity assessment, and the monitoring of endocrine disrupting and dioxin-like compounds has been mostly covered by similarly engineered eukaryotic cells. Some reporter gene assays have been validated, standardized, and accredited, and many others are under constant development. Efforts are aimed at broadening detection spectra, lowering detection thresholds, and combining toxicity identification capabilities with characterization of the toxic effects. Taking advantage of bacterial robustness, attempts are also being made to incorporate bacterial bioreporters into field instrumentation for online continuous monitoring or on-site spot checks. However, key hurdles concerning test validation, cell preservation, and regulatory issues related to the use of genetically modified organisms still remain to be overcome.
Collapse
|
15
|
New methodologies in screening of antibiotic residues in animal-derived foods: Biosensors. Talanta 2017; 175:435-442. [PMID: 28842013 DOI: 10.1016/j.talanta.2017.07.044] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Revised: 05/15/2017] [Accepted: 07/13/2017] [Indexed: 01/05/2023]
Abstract
Antibiotics are leading medicine asset for fighting against microbial infection, but also one of the important causes of death worldwide. Many antibiotics used as therapeutics and growth promotion agents in animals can lead to antibiotic residues in animal-derived food which harm the health of people. Hence, it is vital to screen antibiotic residues in animal derived foods. Typical methods for screening antibiotic residues are based on microbiological growth inhibition and immunological analyses. However these two methods have some disadvantages, such as poor sensitive, lack of specificity and etc. Therefore, it is necessary to develop simple, more efficient and high sensitive screening methods of antibiotic residues. These assays have been introduced for the screening of numerous food samples. Biosensors are emerging methods, applied in screening antibiotic residues in animal-derived foods. Two types of biosensors, whole-cell based biosensors and surface plasmon resonance-based sensors have been extensively used. Their advantages include portability, small sample requirement, high sensitivity and good specificity over the traditional screening methods.
Collapse
|
16
|
Shemer B, Koshet O, Yagur-Kroll S, Belkin S. Microbial bioreporters of trace explosives. Curr Opin Biotechnol 2017; 45:113-119. [PMID: 28319855 DOI: 10.1016/j.copbio.2017.03.003] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Revised: 02/28/2017] [Accepted: 03/02/2017] [Indexed: 12/27/2022]
Abstract
Since its introduction as an explosive in the late 19th century, 2,4,6-trinitrotoluene (TNT), along with other explosive compounds, has left numerous environmental marks. One of these is widespread soil and water pollution by trace explosives in military proving grounds, manufacturing facilities, or actual battlefields. Another dramatic impact is that exerted by the millions of landmines and other explosive devices buried in large parts of the world, causing extensive loss of life, injuries, and economical damage. In this review we highlight recent advances in the design and construction of microbial bioreporters, molecularly engineered to generate a quantifiable dose-dependent signal in the presence of trace amounts of explosives. Such sensor strains may be employed for monitoring environmental pollution as well as for the remote detection of buried landmines.
Collapse
Affiliation(s)
- Benjamin Shemer
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - Ori Koshet
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - Sharon Yagur-Kroll
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - Shimshon Belkin
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, The Hebrew University of Jerusalem, Jerusalem, Israel.
| |
Collapse
|
17
|
Brutesco C, Prévéral S, Escoffier C, Descamps ECT, Prudent E, Cayron J, Dumas L, Ricquebourg M, Adryanczyk-Perrier G, de Groot A, Garcia D, Rodrigue A, Pignol D, Ginet N. Bacterial host and reporter gene optimization for genetically encoded whole cell biosensors. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2017; 24:52-65. [PMID: 27234828 DOI: 10.1007/s11356-016-6952-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2016] [Accepted: 05/20/2016] [Indexed: 06/05/2023]
Abstract
Whole-cell biosensors based on reporter genes allow detection of toxic metals in water with high selectivity and sensitivity under laboratory conditions; nevertheless, their transfer to a commercial inline water analyzer requires specific adaptation and optimization to field conditions as well as economical considerations. We focused here on both the influence of the bacterial host and the choice of the reporter gene by following the responses of global toxicity biosensors based on constitutive bacterial promoters as well as arsenite biosensors based on the arsenite-inducible Pars promoter. We observed important variations of the bioluminescence emission levels in five different Escherichia coli strains harboring two different lux-based biosensors, suggesting that the best host strain has to be empirically selected for each new biosensor under construction. We also investigated the bioluminescence reporter gene system transferred into Deinococcus deserti, an environmental, desiccation- and radiation-tolerant bacterium that would reduce the manufacturing costs of bacterial biosensors for commercial water analyzers and open the field of biodetection in radioactive environments. We thus successfully obtained a cell survival biosensor and a metal biosensor able to detect a concentration as low as 100 nM of arsenite in D. deserti. We demonstrated that the arsenite biosensor resisted desiccation and remained functional after 7 days stored in air-dried D. deserti cells. We also report here the use of a new near-infrared (NIR) fluorescent reporter candidate, a bacteriophytochrome from the magnetotactic bacterium Magnetospirillum magneticum AMB-1, which showed a NIR fluorescent signal that remained optimal despite increasing sample turbidity, while in similar conditions, a drastic loss of the lux-based biosensors signal was observed.
Collapse
Affiliation(s)
- Catherine Brutesco
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Sandra Prévéral
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Camille Escoffier
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Elodie C T Descamps
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Elsa Prudent
- Université de Lyon, Lyon, 69003, France
- INSA de Lyon, Villeurbanne, 69621, France
- CNRS, UMR5240, Microbiologie, Adaptation et Pathogénie, Université Lyon 1, Villeurbanne, 69622, France
| | - Julien Cayron
- Université de Lyon, Lyon, 69003, France
- INSA de Lyon, Villeurbanne, 69621, France
- CNRS, UMR5240, Microbiologie, Adaptation et Pathogénie, Université Lyon 1, Villeurbanne, 69622, France
| | - Louis Dumas
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Manon Ricquebourg
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Géraldine Adryanczyk-Perrier
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Arjan de Groot
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Daniel Garcia
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Agnès Rodrigue
- Université de Lyon, Lyon, 69003, France
- INSA de Lyon, Villeurbanne, 69621, France
- CNRS, UMR5240, Microbiologie, Adaptation et Pathogénie, Université Lyon 1, Villeurbanne, 69622, France
| | - David Pignol
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France
| | - Nicolas Ginet
- CEA, DRF, BIAM, Lab Bioenerget Cellulaire, Saint-Paul-lez-Durance, 13108, France.
- CNRS, UMR Biol Veget and Microbiol Environ, Saint-Paul-lez-Durance, 13108, France.
- Aix-Marseille Université, Saint-Paul-lez-Durance, 13108, France.
| |
Collapse
|
18
|
SOS gene induction and possible mutagenic effects of freeze-drying in Escherichia coli and Salmonella typhimurium. Appl Microbiol Biotechnol 2016; 100:9255-9264. [DOI: 10.1007/s00253-016-7751-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Revised: 07/11/2016] [Accepted: 07/19/2016] [Indexed: 10/21/2022]
|
19
|
Recent Advances in Genetic Technique of Microbial Report Cells and Their Applications in Cell Arrays. BIOMED RESEARCH INTERNATIONAL 2015; 2015:182107. [PMID: 26436087 PMCID: PMC4576000 DOI: 10.1155/2015/182107] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Accepted: 08/26/2015] [Indexed: 11/21/2022]
Abstract
Microbial cell arrays have attracted consistent attention for their ability to provide unique global data on target analytes at low cost, their capacity for readily detectable and robust cell growth in diverse environments, their high degree of convenience, and their capacity for multiplexing via incorporation of molecularly tailored reporter cells. To highlight recent progress in the field of microbial cell arrays, this review discusses research on genetic engineering of reporter cells, technologies for patterning live cells on solid surfaces, cellular immobilization in different polymers, and studies on their application in environmental monitoring, disease diagnostics, and other related fields. On the basis of these results, we discuss current challenges and future prospects for novel microbial cell arrays, which show promise for use as potent tools for unraveling complex biological processes.
Collapse
|
20
|
Wang YZ, Li D, He M. Application of internal standard method in recombinant luminescent bacteria test. J Environ Sci (China) 2015; 35:128-134. [PMID: 26354701 DOI: 10.1016/j.jes.2015.03.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2014] [Revised: 03/07/2015] [Accepted: 03/16/2015] [Indexed: 06/05/2023]
Abstract
Mercury and its organic compounds have been of severe concern worldwide due to their damage to the ecosystem and human health. The development of effective and affordable technology to monitor and signal the presence of bioavailable mercury is an urgent need. The Mer gene is a mercury-responsive resistant gene, and a mercury-sensing recombinant luminescent bacterium using the Mer gene was constructed in this study. The mer operon from marine Pseudomonas putida strain SP1 was amplified and fused with prompterless luxCDABE in the pUCD615 plasmid within Escherichia coli cells, resulting in pTHE30-E. coli. The recombinant strain showed high sensitivity and specificity. The detection limit of Hg(2+) was 5nmol/L, and distinct luminescence could be detected in 30min. Cd(2+), Cu(2+), Zn(2+), Ca(2+), Pb(2+), Mg(2+), Mn(2+), and Al(3+) did not interfere with the detection over a range of 10(-5)-1mM. Application of recombinant luminescent bacteria testing in environmental samples has been a controversial issue: especially for metal-sensing recombinant strains, false negatives caused by high cytotoxicity are one of the most important issues when applying recombinant luminescent bacteria in biomonitoring of heavy metals. In this study, by establishing an internal standard approach, the false negative problem was overcome; furthermore, the method can also help to estimate the suspected mercury concentration, which ensures high detection sensitivity of bioavailable Hg(2+).
Collapse
Affiliation(s)
- Yong-Zhi Wang
- Environmental Simulation and Pollution Control (ESPC) State Key Joint Laboratory, School of Environment, Tsinghua University, Beijing 100084, China. E-mail: .
| | - Dan Li
- Fudan University, Department of Environmental Science & Engineering, Shanghai 200433, China
| | - Miao He
- Environmental Simulation and Pollution Control (ESPC) State Key Joint Laboratory, School of Environment, Tsinghua University, Beijing 100084, China. E-mail: .
| |
Collapse
|
21
|
Jia K, Ionescu RE. Measurement of Bacterial Bioluminescence Intensity and Spectrum: Current Physical Techniques and Principles. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2015; 154:19-45. [PMID: 25981856 DOI: 10.1007/10_2015_324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
: Bioluminescence is light production by living organisms, which can be observed in numerous marine creatures and some terrestrial invertebrates. More specifically, bacterial bioluminescence is the "cold light" produced and emitted by bacterial cells, including both wild-type luminescent and genetically engineered bacteria. Because of the lively interplay of synthetic biology, microbiology, toxicology, and biophysics, different configurations of whole-cell biosensors based on bacterial bioluminescence have been designed and are widely used in different fields, such as ecotoxicology, food toxicity, and environmental pollution. This chapter first discusses the background of the bioluminescence phenomenon in terms of optical spectrum. Platforms for bacterial bioluminescence detection using various techniques are then introduced, such as a photomultiplier tube, charge-coupled device (CCD) camera, micro-electro-mechanical systems (MEMS), and complementary metal-oxide-semiconductor (CMOS) based integrated circuit. Furthermore, some typical biochemical methods to optimize the analytical performances of bacterial bioluminescent biosensors/assays are reviewed, followed by a presentation of author's recent work concerning the improved sensitivity of a bioluminescent assay for pesticides. Finally, bacterial bioluminescence as implemented in eukaryotic cells, bioluminescent imaging, and cancer cell therapies is discussed.
Collapse
Affiliation(s)
- Kun Jia
- Laboratoire de Nanotechnologie et d'Instrumentation Optique, Institut Charles Delaunay, Université de Technologie de Troyes, UMR CNRS 6281, 12 rue Marie Curie CS 42060, TROYES, 10004 Cedex, France
| | - Rodica Elena Ionescu
- Laboratoire de Nanotechnologie et d'Instrumentation Optique, Institut Charles Delaunay, Université de Technologie de Troyes, UMR CNRS 6281, 12 rue Marie Curie CS 42060, TROYES, 10004 Cedex, France.
| |
Collapse
|
22
|
Detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene by an Escherichia coli bioreporter: performance enhancement by directed evolution. Appl Microbiol Biotechnol 2015; 99:7177-88. [DOI: 10.1007/s00253-015-6607-0] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2015] [Revised: 04/02/2015] [Accepted: 04/12/2015] [Indexed: 11/26/2022]
|
23
|
Tsai HF, Tsai YC, Yagur-Kroll S, Palevsky N, Belkin S, Cheng JY. Water pollutant monitoring by a whole cell array through lens-free detection on CCD. LAB ON A CHIP 2015; 15:1472-1480. [PMID: 25608666 DOI: 10.1039/c4lc01189a] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Environmental contamination has become a serious problem to human and environmental health, as exposure to a wide range of possible contaminants continuously increases due to industrial and agricultural activities. Whole cell sensors have been proposed as a powerful tool to detect class-specific toxicants based upon their biological activity and bioavailability. We demonstrated a robust toxicant detection platform based on a bioluminescence whole cell sensor array biochip (LumiChip). LumiChip harbors an integrated temperature control and a 16-member sensor array, as well as a simple but highly efficient luminescence collection setup. On LumiChip, samples were infused in an oxygen-permeable microfluidic flow channel to reach the sensor array. Time-lapse changes in bioluminescence emitted by the array members were measured on a single window-removed linear charge-coupled device (CCD) commonly used in commercial industrial process control or in barcode readers. Removal of the protective window on the linear CCD allowed lens-free direct interfacing of LumiChip to the CCD surface for measurement with high light collection efficiency. Bioluminescence induced by simulated contamination events was detected within 15 to 45 minutes. The portable LumiSense system utilizing the linear CCD in combination with the miniaturized LumiChip is a promising potential platform for on-site environmental monitoring of toxicant contamination.
Collapse
Affiliation(s)
- Hsieh-Fu Tsai
- Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan.
| | | | | | | | | | | |
Collapse
|
24
|
Natan M, Gutman O, Lavi R, Margel S, Banin E. Killing mechanism of stable N-halamine cross-linked polymethacrylamide nanoparticles that selectively target bacteria. ACS NANO 2015; 9:1175-1188. [PMID: 25602279 DOI: 10.1021/nn507168x] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Increased resistance of bacteria to disinfection and antimicrobial treatment poses a serious public health threat worldwide. This has prompted the search for agents that can inhibit both bacterial growth and withstand harsh conditions (e.g., high organic loads). In the current study, N-halamine-derivatized cross-linked polymethacrylamide nanoparticles (NPs) were synthesized by copolymerization of the monomer methacrylamide (MAA) and the cross-linker monomer N,N-methylenebis(acrylamide) (MBAA) and were subsequently loaded with oxidative chlorine using sodium hypochlorite (NaOCl). The chlorinated NPs demonstrated remarkable stability and durability to organic reagents and to repetitive bacterial loading cycles as compared with the common disinfectant NaOCl (bleach), which was extremely labile under these conditions. The antibacterial mechanism of the cross-linked P(MAA-MBAA)-Cl NPs was found to involve generation of reactive oxygen species (ROS) only upon exposure to organic media. Importantly, ROS were not generated upon suspension in water, revealing that the mode of action is target-specific. Further, a unique and specific interaction of the chlorinated NPs with Staphylococcus aureus was discovered, whereby these microorganisms were all specifically targeted and marked for destruction. This bacterial encircling was achieved without using a targeting module (e.g., an antibody or a ligand) and represents a highly beneficial, natural property of the P(MAA-MBAA)-Cl nanostructures. Our findings provide insights into the mechanism of action of P(MAA-MBAA)-Cl NPs and demonstrate the superior efficacy of the NPs over bleach (i.e., stability, specificity, and targeting). This work underscores the potential of developing sustainable P(MAA-MBAA)-Cl NP-based devices for inhibiting bacterial colonization and growth.
Collapse
Affiliation(s)
- Michal Natan
- The Mina and Everard Goodman Faculty of Life Sciences, ‡The Department of Chemistry, and §The Institute for Advanced Materials and Nanotechnology, Bar-Ilan University , Ramat-Gan 52900, Israel
| | | | | | | | | |
Collapse
|
25
|
Campbell-Valois FX, Sansonetti PJ. Tracking bacterial pathogens with genetically-encoded reporters. FEBS Lett 2014; 588:2428-36. [PMID: 24859085 DOI: 10.1016/j.febslet.2014.05.022] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2014] [Accepted: 05/12/2014] [Indexed: 11/15/2022]
Abstract
During the infectious process, bacterial pathogens are subject to changes in environmental conditions such as nutrient availability, immune response challenges, bacterial density and physical contacts with targeted host cells. These conditions occur in the colonized organs, in diverse regions within infected tissues or even at the subcellular level for intracellular pathogens. Integration of environmental cues leads to measurable biological responses in the bacterium required for adaptation. Recent progress in technology enabled the study of bacterial adaptation in situ using genetically encoded reporters that allow single cell analysis or whole body imaging based on fluorescent proteins, alternative fluorescent assays or luciferases. This review presents a historical perspective and technical details on the methods used to develop transcriptional reporters, protein-protein interaction assays and secretion detection assays to study pathogenic bacteria adaptation in situ. Finally, studies published in the last 5 years on gram positive and gram negative bacterial adaptation to the host during infection are discussed. However, the methods described here could easily be extended to study complex microbial communities within host tissue and in the environment.
Collapse
Affiliation(s)
- F-X Campbell-Valois
- Institut Pasteur, Unité de Pathogénie Microbienne Moléculaire, 25-28 rue du Docteur-Roux, 75724 Paris, France; INSERM, U786, 75015 Paris, France
| | - Philippe J Sansonetti
- Institut Pasteur, Unité de Pathogénie Microbienne Moléculaire, 25-28 rue du Docteur-Roux, 75724 Paris, France; INSERM, U786, 75015 Paris, France; Collège de France, Chaire de Microbiologie et Maladies infectieuses, 11 Place Marcelin Berthelot, 75005 Paris, France.
| |
Collapse
|
26
|
Molecular manipulations for enhancing luminescent bioreporters performance in the detection of toxic chemicals. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2014; 145:137-49. [PMID: 25216954 DOI: 10.1007/978-3-662-43619-6_4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Microbial whole-cell bioreporters are genetically modified microorganisms that produce a quantifiable output in response to the presence of toxic chemicals or other stress factors. These bioreporters harbor a genetic fusion between a sensing element (usually a gene regulatory element responsive to the target) and a reporter element, the product of which may be quantitatively monitored either by its presence or by its activity. In this chapter we review genetic manipulations undertaken in order to improve bioluminescent bioreporter performance by increasing luminescent output, lowering the limit of detection, and shortening the response time. We describe molecular manipulations applied to all aspects of whole-cell bioreporters: the host strain, the expression system, the sensing element, and the reporter element. The molecular construction of whole-cell luminescent bioreporters, harboring fusions of gene promoter elements to reporter genes, has been around for over three decades; in most cases, these two genetic elements are combined "as is." This chapter outlines diverse molecular manipulations for enhancing the performance of such sensors.
Collapse
|
27
|
Serum complement enhances the responses of genotoxin- and oxidative stress-sensitive Escherichia coli bioreporters. Biosens Bioelectron 2013; 46:175-82. [PMID: 23545153 DOI: 10.1016/j.bios.2013.02.038] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2012] [Revised: 12/27/2012] [Accepted: 02/19/2013] [Indexed: 11/21/2022]
Abstract
Bacterial bioreporters are limited in their abilities to detect large polar molecules due to their membrane selectivity. In this study, the activity of serum complement was used to bypass this undesired selectivity. Initially, the serum complement activity was assessed using the responses of a bacterial bioreporter harboring a recA::luxCDABE transcriptional fusion when exposed to the chemotherapy drug, mitomycin C (MMC). Using 50 °C-treated serum, the limit of detection for this bacterial sensor was lowered by nearly 450-fold, from 31 μg/L to 0.07 μg/L MMC. Real-time quantitative PCR demonstrated that serum-treated cultures responded more strongly to 100 μg/L MMC, with 3.1-fold higher recA expression levels. Subsequent experiments with other bioreporter strains also found enhanced sensitivities and responses. Finally, combining each of the above findings, tests were performed to demonstrate the potential application of the recA::luxCDABE bioreporter within a lab-on-a-CD platform as a point-of-care diagnostic to measure chemotherapeutic drug concentrations within blood.
Collapse
|
28
|
Xu T, Close DM, Sayler GS, Ripp S. Genetically modified whole-cell bioreporters for environmental assessment. ECOLOGICAL INDICATORS 2013; 28:125-141. [PMID: 26594130 PMCID: PMC4649933 DOI: 10.1016/j.ecolind.2012.01.020] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Living whole-cell bioreporters serve as environmental biosentinels that survey their ecosystems for harmful pollutants and chemical toxicants, and in the process act as human and other higher animal proxies to pre-alert for unfavorable, damaging, or toxic conditions. Endowed with bioluminescent, fluorescent, or colorimetric signaling elements, bioreporters can provide a fast, easily measured link to chemical contaminant presence, bioavailability, and toxicity relative to a living system. Though well tested in the confines of the laboratory, real-world applications of bioreporters are limited. In this review, we will consider bioreporter technologies that have evolved from the laboratory towards true environmental applications, and discuss their merits as well as crucial advancements that still require adoption for more widespread utilization. Although the vast majority of environmental monitoring strategies rely upon bioreporters constructed from bacteria, we will also examine environmental biosensing through the use of less conventional eukaryotic-based bioreporters, whose chemical signaling capacity facilitates a more human-relevant link to toxicity and health-related consequences.
Collapse
Affiliation(s)
- Tingting Xu
- The University of Tennessee Center for Environmental Biotechnology, 676 Dabney Hall, Knoxville, TN 37996, USA
| | - Dan M. Close
- The Joint Institute for Biological Sciences, Oak Ridge National Laboratory, PO Box 2008, MS6342 Oak Ridge, TN 37831, USA
| | - Gary S. Sayler
- The University of Tennessee Center for Environmental Biotechnology, 676 Dabney Hall, Knoxville, TN 37996, USA
- The Joint Institute for Biological Sciences, Oak Ridge National Laboratory, PO Box 2008, MS6342 Oak Ridge, TN 37831, USA
| | - Steven Ripp
- The University of Tennessee Center for Environmental Biotechnology, 676 Dabney Hall, Knoxville, TN 37996, USA
| |
Collapse
|
29
|
Atosuo J, Lehtinen J, Vojtek L, Lilius EM. Escherichia coli K-12 (pEGFPluxABCDEamp): a tool for analysis of bacterial killing by antibacterial agents and human complement activities on a real-time basis. LUMINESCENCE 2012; 28:771-9. [PMID: 23129448 DOI: 10.1002/bio.2435] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Revised: 08/14/2012] [Accepted: 08/14/2012] [Indexed: 11/08/2022]
Abstract
Photorhabdus luminescens luxCDABE genes were integrated into E. coli K-12 using a high copy number plasmid containing modified luxABCDE genes under the control of the powerful Lac promoter. This strain emitted 10 times higher bioluminescence (BL) than P. luminescens. BL production under different growth conditions was studied. In both bacterial strains, the increase in BL signal correlated with the increase in optical density (OD) in a rich growth medium. However, at the logarithmic growth phase, the BL signal was roughly constant. By contrast, in minimal growth media, there was no substantial growth and the BL/cell was approximately five times higher than in the rich medium. The dynamic measurement range of BL was 10(2) -10(7) colony-forming units (CFU) in E. coli and 10(3) -10(7) CFU in P. luminescens. Because the decrease in the BL signal correlated with the decrease in CFU and OD, i.e. the number of bacterial cells killed, it proved to be very suitable for assessing the antibacterial effects of different antimicrobial agents. Unlike with plate counting, the kinetics of killing can be monitored on a real-time basis using BL measurements. Complement activities in different samples can be estimated using only one serum dilution. The transformed E. coli strain appeared to be superior to P. luminescens in these applications because E. coli was complement sensitive, the detection limit of E. coli was one order lower and the BL-producing system of P. luminescens appeared to be quite unstable.
Collapse
Affiliation(s)
- Janne Atosuo
- Department of Biochemistry and Food Chemistry, The University of Turku, Turku, Finland
| | | | | | | |
Collapse
|
30
|
Ranjan R, Rastogi NK, Thakur MS. Development of immobilized biophotonic beads consisting of Photobacterium leiognathi for the detection of heavy metals and pesticide. JOURNAL OF HAZARDOUS MATERIALS 2012; 225-226:114-123. [PMID: 22626628 DOI: 10.1016/j.jhazmat.2012.04.076] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2012] [Revised: 04/10/2012] [Accepted: 04/30/2012] [Indexed: 06/01/2023]
Abstract
The present communication deals with construction of immobilized robust biophotonic bead using P. leiognathi, a marine luminescent bacterium for their possible application in monitoring of environmental toxicants. Immobilization efficiency of agar, carrageenan and sodium alginate was evaluated separately in terms of luminescence response and was recorded as 30.3, 77.4 or 99.5%, respectively. Under optimized storage conditions, the luminescent response of P. leiognathi in the immobilized state was studied over a period of 30 days. These biophotonic beads were further used as a rapid and reliable optical biosensing tool for the detection of heavy metals [Hg(II), As(V) or Cd(II)] and pesticide [2,4-dichlorophenoxyacetic acid (2,4-D)] in water systems. The concentration range for the detection of Hg(II), As(V), Cd(II) and 2,4-D was 2-32ppm, 4-128ppm, 16-512ppm and 100-600ppm, respectively, while corresponding sensitivity threshold was 2.0ppm, 4.0ppm, 16.0ppm and 100ppm. A comparison of inhibition constant (K(d)) (or EC(20)) values indicated that the sensitivity thresholds rank as Hg(II)>As(V)>Cd(II)>2,4-D. Moreover, the time taken for the detection of heavy metals and pesticide was less than 30min. Using the bioluminescence inhibition method, the concentration of heavy metals and pesticide could be predicted.
Collapse
Affiliation(s)
- Rajeev Ranjan
- Fermentation Technology and Bioengineering Department, Central Food Technological Research Institute, Mysore 570020, India
| | | | | |
Collapse
|
31
|
Melamed S, Lalush C, Elad T, Yagur‐Kroll S, Belkin S, Pedahzur R. A bacterial reporter panel for the detection and classification of antibiotic substances. Microb Biotechnol 2012; 5:536-48. [PMID: 22385678 PMCID: PMC3815330 DOI: 10.1111/j.1751-7915.2012.00333.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2011] [Accepted: 01/25/2012] [Indexed: 12/05/2022] Open
Abstract
The ever-growing use of pharmaceutical compounds, including antibacterial substances, poses a substantial pollution load on the environment. Such compounds can compromise water quality, contaminate soils, livestock and crops, enhance resistance of microorganisms to antibiotic substances, and hamper human health. We report the construction of a novel panel of genetically engineered Escherichia coli reporter strains for the detection and classification of antibiotic substances. Each of these strains harbours a plasmid that carries a fusion of a selected gene promoter to bioluminescence (luxCDABE) reporter genes and an alternative tryptophan auxotrophy-based non-antibiotic selection system. The bioreporter panel was tested for sensitivity and responsiveness to diverse antibiotic substances by monitoring bioluminescence as a function of time and of antibiotic concentrations. All of the tested antibiotics were detected by the panel, which displayed different response patterns for each substance. These unique responses were analysed by several algorithms that enabled clustering the compounds according to their functional properties, and allowed the classification of unknown antibiotic substances with a high degree of accuracy and confidence.
Collapse
Affiliation(s)
- Sahar Melamed
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, the Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Chaim Lalush
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, the Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Tal Elad
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, the Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Sharon Yagur‐Kroll
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, the Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Shimshon Belkin
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, the Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Rami Pedahzur
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, the Hebrew University of Jerusalem, Jerusalem 91904, Israel
- Department of Environmental Sciences, Hadassah Academic College, Jerusalem, Israel
| |
Collapse
|
32
|
Melamed S, Elad T, Belkin S. Microbial sensor cell arrays. Curr Opin Biotechnol 2012; 23:2-8. [DOI: 10.1016/j.copbio.2011.11.024] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2011] [Revised: 11/16/2011] [Accepted: 11/23/2011] [Indexed: 11/29/2022]
|
33
|
The evolution of the bacterial luciferase gene cassette (lux) as a real-time bioreporter. SENSORS 2012; 12:732-52. [PMID: 22368493 PMCID: PMC3279237 DOI: 10.3390/s120100732] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2011] [Revised: 12/30/2011] [Accepted: 01/09/2012] [Indexed: 01/23/2023]
Abstract
The bacterial luciferase gene cassette (lux) is unique among bioluminescent bioreporter systems due to its ability to synthesize and/or scavenge all of the substrate compounds required for its production of light. As a result, the lux system has the unique ability to autonomously produce a luminescent signal, either continuously or in response to the presence of a specific trigger, across a wide array of organismal hosts. While originally employed extensively as a bacterial bioreporter system for the detection of specific chemical signals in environmental samples, the use of lux as a bioreporter technology has continuously expanded over the last 30 years to include expression in eukaryotic cells such as Saccharomyces cerevisiae and even human cell lines as well. Under these conditions, the lux system has been developed for use as a biomedical detection tool for toxicity screening and visualization of tumors in small animal models. As the technologies for lux signal detection continue to improve, it is poised to become one of the first fully implantable detection systems for intra-organismal optical detection through direct marriage to an implantable photon-detecting digital chip. This review presents the basic biochemical background that allows the lux system to continuously autobioluminesce and highlights the important milestones in the use of lux-based bioreporters as they have evolved from chemical detection platforms in prokaryotic bacteria to rodent-based tumorigenesis study targets. In addition, the future of lux imaging using integrated circuit microluminometry to image directly within a living host in real-time will be introduced and its role in the development of dose/response therapeutic systems will be highlighted.
Collapse
|
34
|
Application of bioluminescence imaging for in vivo monitoring of fungal infections. Int J Microbiol 2011; 2012:956794. [PMID: 22121368 PMCID: PMC3205719 DOI: 10.1155/2012/956794] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2011] [Accepted: 08/23/2011] [Indexed: 11/24/2022] Open
Abstract
Fungi can cause severe invasive infections especially in the immunocompromised host. Patient populations at risk are increasing due to ongoing developments in cancer treatment and transplantation medicine. Only limited diagnostic tools and few antifungals are available, rendering a significant number of invasive fungal infections life threatening. To reduce mortality rates, a better understanding of the infection processes is urgently required. Bioluminescence imaging (BLI) is a powerful tool for such purposes, since it allows visualisation of temporal and spatial progression of infections in real time. BLI has been successfully used to monitor infections caused by various microorganisms, in particular bacteria. However, first studies have also been performed on the fungi Candida albicans and Aspergillus fumigatus. Although BLI was, in principle, suitable to study the infection process, some limitations remained. Here, different luciferase systems are introduced, and current approaches are summarised. Finally, suggestions for further improvements of BLI to monitor fungal infections are provided.
Collapse
|
35
|
Elad T, Almog R, Yagur-Kroll S, Levkov K, Melamed S, Shacham-Diamand Y, Belkin S. Online monitoring of water toxicity by use of bioluminescent reporter bacterial biochips. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2011; 45:8536-8544. [PMID: 21875062 DOI: 10.1021/es202465c] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We describe a flow-through biosensor for online continuous water toxicity monitoring. At the heart of the device are disposable modular biochips incorporating agar-immobilized bioluminescent recombinant reporter bacteria, the responses of which are probed by single-photon avalanche diode detectors. To demonstrate the biosensor capabilities, we equipped it with biochips harboring both inducible and constitutive reporter strains and exposed it to a continuous water flow for up to 10 days. During these periods we challenged the biosensor with 2-h pulses of water spiked with model compounds representing different classes of potential water pollutants, as well as with a sample of industrial wastewater. The biosensor reporter panel detected all simulated contamination events within 0.5-2.5 h, and its response was indicative of the nature of the contaminating chemicals. We believe that a biosensor of the proposed design can be integrated into future water safety and security networks, as part of an early warning system against accidental or intentional water pollution by toxic chemicals.
Collapse
Affiliation(s)
- Tal Elad
- Department of Plant and Environmental Sciences, The Alexander Silberman Institute of Life Sciences, The Hebrew University of Jerusalem , Jerusalem 91904, Israel
| | | | | | | | | | | | | |
Collapse
|
36
|
Staying alive: new perspectives on cell immobilization for biosensing purposes. Anal Bioanal Chem 2011; 402:1785-97. [PMID: 21922308 DOI: 10.1007/s00216-011-5364-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2011] [Revised: 08/10/2011] [Accepted: 08/24/2011] [Indexed: 01/09/2023]
|
37
|
Woutersen M, Belkin S, Brouwer B, van Wezel AP, Heringa MB. Are luminescent bacteria suitable for online detection and monitoring of toxic compounds in drinking water and its sources? Anal Bioanal Chem 2011; 400:915-29. [PMID: 21058029 PMCID: PMC3074085 DOI: 10.1007/s00216-010-4372-6] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2010] [Revised: 10/21/2010] [Accepted: 10/21/2010] [Indexed: 11/26/2022]
Abstract
Biosensors based on luminescent bacteria may be valuable tools to monitor the chemical quality and safety of surface and drinking water. In this review, an overview is presented of the recombinant strains available that harbour the bacterial luciferase genes luxCDABE, and which may be used in an online biosensor for water quality monitoring. Many bacterial strains have been described for the detection of a broad range of toxicity parameters, including DNA damage, protein damage, membrane damage, oxidative stress, organic pollutants, and heavy metals. Most lux strains have sensitivities with detection limits ranging from milligrams per litre to micrograms per litre, usually with higher sensitivities in compound-specific strains. Although the sensitivity of lux strains can be enhanced by various molecular manipulations, most reported detection thresholds are still too high to detect levels of individual contaminants as they occur nowadays in European drinking waters. However, lux strains sensing specific toxic effects have the advantage of being able to respond to mixtures of contaminants inducing the same effect, and thus could be used as a sensor for the sum effect, including the effect of compounds that are as yet not identified by chemical analysis. An evaluation of the suitability of lux strains for monitoring surface and drinking water is therefore provided.
Collapse
|
38
|
Sitaras C, Beyde A, Malekazari P, Herrington MB. Light producing reporter plasmids for Escherichia coli K-12 that can be integrated into the chromosome. Plasmid 2011; 65:232-8. [PMID: 21376749 DOI: 10.1016/j.plasmid.2011.02.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2010] [Revised: 02/24/2011] [Accepted: 02/25/2011] [Indexed: 10/18/2022]
Abstract
Plasmid vectors using the Photorhabdus luminescenslux operon can be used for real time measurements of promoter activity. We have generated a series of lux vectors that have a conditional origin of replication, different selectable markers and the attP sequence from λ. Single copies of these plasmids can be integrated into the λ attachment site in the Escherichia coli chromosome. We constructed reporter derivatives and compared light production when the plasmids were present in multiple copies and in single copies. We also demonstrated that expression could be induced under the appropriate conditions.
Collapse
Affiliation(s)
- Chris Sitaras
- Biology Department, Concordia University, Montreal, QC H4B1R6, Canada
| | | | | | | |
Collapse
|