1
|
Cheng F, Lv B, Huang Y, Tang Y, Mei D, Huang B, Zhao X. Facile Synthesis and Characterization of Fluorescent Polystyrene Nanospheres for Homogeneous Light-Initiated Chemiluminescence Immunoassay. J Fluoresc 2024. [DOI: 10.1007/s10895-024-03965-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Accepted: 09/26/2024] [Indexed: 01/04/2025]
|
2
|
Chen J, Fu B, Xiang Z, Chen X, Wang L, Qin Y, Zhao X, Zhou X, Liu P, Huang B. Sensitive amplified luminescent proximity homogeneous assay for the quantitative detection of CA242. J Immunol Methods 2023; 517:113487. [PMID: 37156407 DOI: 10.1016/j.jim.2023.113487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/10/2023]
Abstract
We here developed a sensitive and stable amplified luminescent proximity homogeneous assay (AlphaLISA) method for fast quantification of CA242 in human serum. Donor and acceptor beads modified with carboxyl groups could be coupled with CA242 antibodies after activation in the AlphaLISA method. CA242 was rapidly detected by the double antibody sandwich immunoassay. The method yielded good linearity (>0.996) and detection range (0.16-400 U/mL). The intra-assay precisions of CA242-AlphaLISA were between 3.43% and 6.81% (< 10%), and the inter-assay precisions were between 4.06% and 9.56% (< 15%). The relative recoveries ranged from 89.61% to 107.29%. Detection time for the CA242-AlphaLISA method was only 20 min. Moreover, results of CA242-AlphaLISA and time-resolved fluorescence immunoassay had satisfactory correlation and consistency (ρ = 0.9852). The method was successfully applied to the analysis of human serum samples. Meanwhile, serum CA242 has a good detection value in the identification and diagnosis of pancreatic cancer and the monitoring of disease degree. Furthermore, the proposed AlphaLISA method is expected to be an alternative to traditional detection methods, laying a good foundation for the further development of kits to detect other biomarkers in future studies.
Collapse
Affiliation(s)
- Jianye Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Benqi Fu
- Sichuan Friendship Hospital, Chengdu, China
| | - Zhongyi Xiang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xindong Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Lu Wang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xueqin Zhao
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xiumei Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Pengfei Liu
- Department of Gastroenterology, The Jiangyin Clinical College of Xuzhou Medical University, Wuxi, People's Republic of China
| | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| |
Collapse
|
3
|
Development of amplified luminescent proximity homogeneous assay for quantitation of gastrin-17. Anal Biochem 2023; 662:115016. [PMID: 36502889 DOI: 10.1016/j.ab.2022.115016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 12/07/2022] [Indexed: 12/14/2022]
Abstract
A highly sensitive and convenient amplified luminescent proximity homogeneous assay (AlphaLISA) method with high throughput and automation potential was developed for quantitation of serum Gastrin-17 (G-17) levels, which can facilitate the early diagnosis of atrophic gastritis in people at high risk of gastric cancer using a non-invasive approach. In this study, donor and acceptor beads with modified carboxyl groups on the surface were directly coupled to anti-G-17 antibodies through activation was proposed for application in the development of the new AlphaLISA, which can effectively simplify the steps and shorten the reaction time to achieve faster detection. Therefore, the G-17-AlphaLISA only needs to react for 15 min to obtain good analysis results. The proposed method has a wider detection range than commercial enzyme-linked immunosorbent assay (ELISA) kits (0.12-112.8 pmol/L > 0.5-40 pmol/L). In addition, results of G-17-AlphaLISA and ELISA had good correlation and agreement (ρ = 0.936). Importantly, the developed method may be more suitable for the large-scale screening of people at high risk for gastric cancer than traditional ELISA and provides a novel solution for other biomarkers that require accurate, highly sensitive, and high throughput detection.
Collapse
|
4
|
Xiang Z, Chen X, Zhou X, Qin Y, Zhao X, Wang Y, Li Q, Huang B. Development and application of a novel aldehyde nanoparticle-based amplified luminescent proximity homogeneous assay for rapid quantitation of pancreatic stone protein. Clin Chim Acta 2022; 535:120-130. [PMID: 36030885 DOI: 10.1016/j.cca.2022.08.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 08/04/2022] [Accepted: 08/20/2022] [Indexed: 11/25/2022]
Abstract
BACKGROUND Timely diagnosis of bacterial infections is important to prevent sepsis. Classical infection biomarkers have some flaws, and common detection methods are time-consuming. Thus, we aimed to establish an efficient detection method that precisely detects pancreatic stone protein (PSP) in human plasma for the timely diagnosis of bacterial infections. METHODS Based on the novel amplified luminescent proximity homogeneous assay (AlphaLISA) method, donor and acceptor beads modified with aldehyde groups were directly coupled to the anti-PSP antibodies. PSP was quickly detected by a double-antibody sandwich method. Plasma samples from healthy individuals, bacterially infected patients, and acute-phase response patients were tested. RESULTS The detection time of the developed method is only 5 min. The results of PSP-AlphaLISA and time-resolved fluorescence were consistent (ρ = 0.9722). The plasma PSP levels of patients with bacterial infection were significantly higher than those of acute-phase response patients and healthy individuals (P < 0.05). PSP levels in patients with bacterial infection with sepsis were significantly higher than those in patients with bacterial infection without sepsis (P < 0.05). CONCLUSIONS The PSP-AlphaLISA exhibited excellent performance and may be applied to the differential diagnosis between bacterial infection and sepsis in patients without interference from patients with acute-phase response.
Collapse
Affiliation(s)
- Zhongyi Xiang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xindong Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xiumei Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xueqin Zhao
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yigang Wang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Qian Li
- Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, China.
| | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| |
Collapse
|
5
|
Xiang Z, Zhang Z, Chen X, Zhang L, Zhou X, Qin Y, Zhao X, Wang Y, Huang B, Tang H. Development and application of amplified luminescent proximity homogeneous assay for quantitation of heparin-binding protein. Anal Biochem 2022; 657:114906. [PMID: 36152874 DOI: 10.1016/j.ab.2022.114906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 09/09/2022] [Accepted: 09/13/2022] [Indexed: 11/29/2022]
Abstract
A fast and highly sensitive amplified luminescent proximity homogeneous assay (AlphaLISA) method was developed for quantitation of plasma heparin-binding protein levels. In this study, a method directly coupling donor and acceptor beads modified with aldehyde groups to anti-HBP antibodies was proposed, which can effectively simplify the steps and shorten the reaction time to achieve faster detection. Therefore, the developed method required only 15 min of reaction time to generate results. Compared with the approved commercial kit, the developed method had a wider linear range (2.78-500 ng/mL). The excellent linear range means that the method can better exploit the value of HBP in clinical applications. Meanwhile, results of amplified luminescent proximity homogeneous assay and fluorescence dry quantitative immunoassay had good correlation and consistency (ρ = 0.9181). Moreover, the plasma HBP concentrations of patients with bacterial infection were significantly higher than those of healthy individuals (P < 0.0001), indicating the potential applicability of the proposed method for predicting the incidence of bacterial infections. Importantly, the newly developed method is expected to serve as an alternative to the traditional assay method and provides a completely new platform for other biomarkers that require rapid detection.
Collapse
Affiliation(s)
- Zhongyi Xiang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Zhibin Zhang
- Clinical Laboratory, Wuxi Hospital of Traditional Chinese Medicine, Wuxi, China
| | - Xindong Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Lele Zhang
- Clinical Laboratory Medicine, Second Affiliated Hospital of Zhejiang University School of Medicine, China
| | - Xiumei Zhou
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yuan Qin
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xueqin Zhao
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Yigang Wang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China
| | - Biao Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China.
| | - Huqiang Tang
- Clinical Laboratory Medicine, Second Affiliated Hospital of Zhejiang University School of Medicine, China.
| |
Collapse
|
6
|
Zhang L, Lv Q, Zheng Y, Chen X, Kong D, Huang W, Liu P, Jiang H, Jiang Y. A rapid and accurate method for screening T-2 toxin in food and feed using competitive AlphaLISA. FEMS Microbiol Lett 2021; 368:6184045. [PMID: 33755724 DOI: 10.1093/femsle/fnab029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 03/19/2021] [Indexed: 01/01/2023] Open
Abstract
T-2 is a common mycotoxin contaminating cereal crops. Chronic consumption of food contaminated with T-2 toxin can lead to death, so simple and accurate detection methods in food and feed are necessary. In this paper, we establish a highly sensitive and accurate method for detecting T-2 toxin using AlphaLISA. The system consists of acceptor beads labeled with T-2-bovine serum albumin (BSA), streptavidin-labeled donor beads and biotinylated T-2 antibodies. T-2 in the sample matrix competes with T-2-BSA for antibodies. Adding biotinylated antibodies to the test well followed by T-2 and T-2-BSA acceptor beads yielded a detection range of 0.03-500 ng/mL. The half-maximal inhibitory concentration was 2.28 ng/mL and the coefficient of variation was <10%. In addition, this method had no cross-reaction with other related mycotoxins. This optimized method for extracting T-2 from food and feed samples achieved a recovery rate of approximately 90% in T-2 concentrations as low as 1 ng/mL, better than the performance of a commercial ELISA kit. This competitive AlphaLISA method offers high sensitivity, good specificity, good repeatability and simple operation for detecting T-2 toxin in food and feed.
Collapse
Affiliation(s)
- Liwen Zhang
- Anhui Medical University, Hefei, Anhui 230032, China.,State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Qingyu Lv
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Yuling Zheng
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Xuan Chen
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Decong Kong
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Wenhua Huang
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Peng Liu
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Hua Jiang
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| | - Yongqiang Jiang
- Anhui Medical University, Hefei, Anhui 230032, China.,State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing 100071, China
| |
Collapse
|
7
|
Tournier JN, Rougeaux C. Anthrax Toxin Detection: From In Vivo Studies to Diagnostic Applications. Microorganisms 2020; 8:microorganisms8081103. [PMID: 32717946 PMCID: PMC7464488 DOI: 10.3390/microorganisms8081103] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 07/19/2020] [Accepted: 07/21/2020] [Indexed: 11/16/2022] Open
Abstract
Anthrax toxins are produced by Bacillus anthracis throughout infection and shape the physiopathogenesis of the disease. They are produced in low quantities but are highly efficient. They have thus been long ignored, but recent biochemical methods have improved our knowledge in animal models. This article reviews the various methods that have been used and how they could be applied to clinical diagnosis.
Collapse
Affiliation(s)
- Jean-Nicolas Tournier
- Unité Bactériologie Biothérapies Anti-infectieuses et Immunité, Institut de Recherche Biomédicale des Armées (IRBA), 1 place Général Valérie André, 91220 Brétigny sur Orge, France;
- Centre National de Référence-Laboratoire Expert Charbon, 1 place Général Valérie André, 91220 Brétigny sur Orge, France
- Innovative Vaccine Laboratory, Institut Pasteur, 28 rue du docteur Roux, 75015 Paris, France
- Ecole du Val-de-Grâce, 1 place Alphonse Laveran, 75005 Paris, France
| | - Clémence Rougeaux
- Unité Bactériologie Biothérapies Anti-infectieuses et Immunité, Institut de Recherche Biomédicale des Armées (IRBA), 1 place Général Valérie André, 91220 Brétigny sur Orge, France;
- Centre National de Référence-Laboratoire Expert Charbon, 1 place Général Valérie André, 91220 Brétigny sur Orge, France
- Correspondence: ; Tel.: +33-178-651-891
| |
Collapse
|
8
|
Wang HB, Du T, Li WG, Zhao JH, Yang Z, Mo QH. The establishment and clinical evaluation of a novel, rapid, no-wash one-step immunoassay for the detection of dengue virus non-structural protein 1. J Virol Methods 2019; 276:113793. [PMID: 31794781 DOI: 10.1016/j.jviromet.2019.113793] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 11/28/2019] [Accepted: 11/30/2019] [Indexed: 10/25/2022]
Abstract
Dengue fever is a highly endemic arthropod-borne viral disease in the tropical and sub-tropical countries and is rapidly becoming a global threaten. Diagnosis has been conducted by either traditional serological methods or molecular biological techniques. However, these methods are either labor-intensive, time-consuming or with multiple steps, which are not suitable for high throughput detection of large quantity of samples. In the current study, a novel, rapid, no-wash one-step amplified luminescent proximity homogenous assay-linked immunosorbent assay (AlphaLISA) was developed and optimized for the diagnosis of dengue fever through the detection of dengue virus non-structural protein 1 (NS1). The linear range of the assay was determined to be 60,000 pg/mL to 200 pg/mL, with a lower detection limit of 127.45 pg/mL for NS1 protein. The precision of the assay was 8.24 % and 4.93 % for the high and low concentration. Clinical evaluation indicated that the sensitivity and specificity of the assay was 91.49 % and 81.54 %, respectively. This novel, rapid, no-wash one-step AlphaLISA assay is convenient and sensitive, which could be a good alternative for the screening of dengue fever in a high throughput format.
Collapse
Affiliation(s)
- Hai-Bo Wang
- Key Laboratory of Emerging Infectious Disease Detection, Zhuhai International Travel Healthcare Center, Gongbei Customs District, Zhuhai 519020, Guangdong, China
| | - Tian Du
- Futian District Center for Disease Prevention and Control, Shenzhen 518040, Guangdong, China
| | - Wei-Gang Li
- Key Laboratory of Emerging Infectious Disease Detection, Zhuhai International Travel Healthcare Center, Gongbei Customs District, Zhuhai 519020, Guangdong, China
| | - Jun-Hua Zhao
- Key Laboratory of Emerging Infectious Disease Detection, Zhuhai International Travel Healthcare Center, Gongbei Customs District, Zhuhai 519020, Guangdong, China
| | - Ze Yang
- Key Laboratory of Emerging Infectious Disease Detection, Zhuhai International Travel Healthcare Center, Gongbei Customs District, Zhuhai 519020, Guangdong, China
| | - Qiu-Hua Mo
- Key Laboratory of Emerging Infectious Disease Detection, Zhuhai International Travel Healthcare Center, Gongbei Customs District, Zhuhai 519020, Guangdong, China.
| |
Collapse
|
9
|
Chelliah R, Wei S, Park BJ, Rubab M, Banan-Mwine Dalirii E, Barathikannan K, Jin YG, Oh DH. Whole genome sequence of Bacillus thuringiensis ATCC 10792 and improved discrimination of Bacillus thuringiensis from Bacillus cereus group based on novel biomarkers. Microb Pathog 2019; 129:284-297. [DOI: 10.1016/j.micpath.2019.02.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 02/08/2019] [Accepted: 02/08/2019] [Indexed: 11/17/2022]
|
10
|
Walper SA, Lasarte Aragonés G, Sapsford KE, Brown CW, Rowland CE, Breger JC, Medintz IL. Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies. ACS Sens 2018; 3:1894-2024. [PMID: 30080029 DOI: 10.1021/acssensors.8b00420] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Although a fundamental understanding of the pathogenicity of most biothreat agents has been elucidated and available treatments have increased substantially over the past decades, they still represent a significant public health threat in this age of (bio)terrorism, indiscriminate warfare, pollution, climate change, unchecked population growth, and globalization. The key step to almost all prevention, protection, prophylaxis, post-exposure treatment, and mitigation of any bioagent is early detection. Here, we review available methods for detecting bioagents including pathogenic bacteria and viruses along with their toxins. An introduction placing this subject in the historical context of previous naturally occurring outbreaks and efforts to weaponize selected agents is first provided along with definitions and relevant considerations. An overview of the detection technologies that find use in this endeavor along with how they provide data or transduce signal within a sensing configuration follows. Current "gold" standards for biothreat detection/diagnostics along with a listing of relevant FDA approved in vitro diagnostic devices is then discussed to provide an overview of the current state of the art. Given the 2014 outbreak of Ebola virus in Western Africa and the recent 2016 spread of Zika virus in the Americas, discussion of what constitutes a public health emergency and how new in vitro diagnostic devices are authorized for emergency use in the U.S. are also included. The majority of the Review is then subdivided around the sensing of bacterial, viral, and toxin biothreats with each including an overview of the major agents in that class, a detailed cross-section of different sensing methods in development based on assay format or analytical technique, and some discussion of related microfluidic lab-on-a-chip/point-of-care devices. Finally, an outlook is given on how this field will develop from the perspective of the biosensing technology itself and the new emerging threats they may face.
Collapse
Affiliation(s)
- Scott A. Walper
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Guillermo Lasarte Aragonés
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Kim E. Sapsford
- OMPT/CDRH/OIR/DMD Bacterial Respiratory and Medical Countermeasures Branch, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Carl W. Brown
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Clare E. Rowland
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- National Research Council, Washington, D.C. 20036, United States
| | - Joyce C. Breger
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Igor L. Medintz
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| |
Collapse
|
11
|
Armstrong CM, Ruth LE, Capobianco JA, Strobaugh TP, Rubio FM, Gehring AG. Detection of Shiga Toxin 2 Produced by Escherichia coli in Foods Using a Novel AlphaLISA. Toxins (Basel) 2018; 10:E422. [PMID: 30360508 PMCID: PMC6265734 DOI: 10.3390/toxins10110422] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Revised: 10/09/2018] [Accepted: 10/17/2018] [Indexed: 12/25/2022] Open
Abstract
Amplified luminescent proximity homogenous assay-linked immunosorbent assay (AlphaLISA) is comprised of a bead-based immunoassay that is used for small molecule detection. In this study, a novel AlphaLISA was developed and optimized for the detection of Shiga-toxin 2 (Stx2). Efficacy and sensitivity trials showed the AlphaLISA could detect ≥0.5 ng/mL of purified Stx2, which was comparable to the industry-standard enzyme-linked immunosorbent assay (ELISA) tests for Stx2 detection. In addition, evaluation of Shiga toxin-producing Escherichia coli (STEC)-inoculated Romaine lettuce and ground beef samples demonstrated that both the AlphaLISA and the ELISA were able to discern uninoculated samples from 1× and 10× diluted samples containing ~10 CFU/mL of STEC enriched in modified tryptic soy broth with mitomycin C for 16 h. Overall, the increased signal-to-noise ratios indicated a more robust signal was produced by the AlphaLISA compared to the ELISA and the delineation of higher toxin concentrations without the need for sample dilution implied a greater dynamic range for the AlphaLISA. Implementation of the newly developed AlphaLISA will allow for more rapid analysis for Stx2 with less manual manipulation, thus improving assay throughput and the ability to automate sample screening while maintaining detection limits of 0.5 ng/mL.
Collapse
Affiliation(s)
- Cheryl M Armstrong
- Molecular Characterization of Foodborne Pathogens Research Unit, United States Department of Agriculture, Eastern Regional Research Center, Wyndmoor, PA 19038, USA.
| | | | - Joseph A Capobianco
- Molecular Characterization of Foodborne Pathogens Research Unit, United States Department of Agriculture, Eastern Regional Research Center, Wyndmoor, PA 19038, USA.
| | - Terence P Strobaugh
- Molecular Characterization of Foodborne Pathogens Research Unit, United States Department of Agriculture, Eastern Regional Research Center, Wyndmoor, PA 19038, USA.
| | | | - Andrew G Gehring
- Molecular Characterization of Foodborne Pathogens Research Unit, United States Department of Agriculture, Eastern Regional Research Center, Wyndmoor, PA 19038, USA.
| |
Collapse
|
12
|
Lassabe G, Kramer K, Hammock BD, González-Sapienza G, González-Techera A. Noncompetitive Homogeneous Detection of Small Molecules Using Synthetic Nanopeptamer-Based Luminescent Oxygen Channeling. Anal Chem 2018; 90:6187-6192. [PMID: 29694028 DOI: 10.1021/acs.analchem.8b00657] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Our group has previously developed immunoassays for noncompetitive detection of small molecules based on the use of phage borne anti-immunocomplex peptides. Recently, we substituted the phage particles by biotinylated synthetic anti-immunocomplex peptides complexed with streptavidin and named these constructs nanopeptamers. In this work, we report the results of combining AlphaLisa, a commercial luminescent oxygen channeling bead system, with nanopeptamers for the development of a noncompetitive homogeneous assay for the detection of small molecules. The signal generation of AlphaLisa assays relies on acceptor-donor bead proximity induced by the presence of the analyte (a macromolecule) simultaneously bound by antibodies immobilized on the surface of these beads. In the developed assay, termed as nanoAlphaLisa, bead proximity is sustained by the presence of a small model molecule (atrazine, MW = 215) using an antiatrazine antibody captured on the acceptor bead and an atrazine nanopeptamer on the donor bead. Atrazine is one of the most used pesticides worldwide, and its monitoring in water has relevant human health implications. NanoAlphaLisa allowed the homogeneous detection of atrazine down to 0.3 ng/mL in undiluted water samples in 1 h, which is 10-fold below the accepted limit in drinking water. NanoAlphaLisa has the intrinsic advantages for automation and high-throughput, simple, and fast homogeneous detection of target analytes that AlphaLisa assay provides.
Collapse
Affiliation(s)
- Gabriel Lassabe
- Cátedra de Inmunología, DEPBIO, Facultad de Química, Instituto de Higiene , UDELAR , Montevideo , 11600 , Uruguay
| | - Karl Kramer
- Chair of Proteomics and Bioanalytics , Technical University of Munich , Freising , 85354 , Germany
| | - Bruce D Hammock
- Department of Entomology and Nematology and UC Davis Comprehensive Cancer Center , University of California , Davis , California 95616 , United States
| | - Gualberto González-Sapienza
- Cátedra de Inmunología, DEPBIO, Facultad de Química, Instituto de Higiene , UDELAR , Montevideo , 11600 , Uruguay
| | - Andrés González-Techera
- Cátedra de Inmunología, DEPBIO, Facultad de Química, Instituto de Higiene , UDELAR , Montevideo , 11600 , Uruguay
| |
Collapse
|
13
|
Senga Y, Imamura H, Miyafusa T, Watanabe H, Honda S. AlphaScreen-based homogeneous assay using a pair of 25-residue artificial proteins for high-throughput analysis of non-native IgG. Sci Rep 2017; 7:12466. [PMID: 28963557 PMCID: PMC5622108 DOI: 10.1038/s41598-017-12693-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Accepted: 09/18/2017] [Indexed: 12/24/2022] Open
Abstract
Therapeutic IgG becomes unstable under various stresses in the manufacturing process. The resulting non-native IgG molecules tend to associate with each other and form aggregates. Because such aggregates not only decrease the pharmacological effect but also become a potential risk factor for immunogenicity, rapid analysis of aggregation is required for quality control of therapeutic IgG. In this study, we developed a homogeneous assay using AlphaScreen and AF.2A1. AF.2A1 is a 25-residue artificial protein that binds specifically to non-native IgG generated under chemical and physical stresses. This assay is performed in a short period of time. Our results show that AF.2A1-AlphaScreen may be used to evaluate the various types of IgG, as AF.2A1 recognizes the non-native structure in the constant region (Fc region) of IgG. The assay was effective for detection of non-native IgG, with particle size up to ca. 500 nm, generated under acid, heat, and stirring conditions. In addition, this technique is suitable for analyzing non-native IgG in CHO cell culture supernatant and mixed with large amounts of native IgG. These results indicate the potential of AF.2A1-AlphaScreen to be used as a high-throughput evaluation method for process monitoring as well as quality testing in the manufacturing of therapeutic IgG.
Collapse
Affiliation(s)
- Yukako Senga
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8566, Japan
| | - Hiroshi Imamura
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8566, Japan
| | - Takamitsu Miyafusa
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8566, Japan
| | - Hideki Watanabe
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8566, Japan
| | - Shinya Honda
- Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki, 305-8566, Japan.
| |
Collapse
|
14
|
Xiong Y, Wu Y, Luo S, Gao Y, Xiong Y, Chen D, Deng H, Hao W, Liu T, Li M. Development of a novel immunoassay to detect interactions with the transactivation domain of p53: application to screening of new drugs. Sci Rep 2017; 7:9185. [PMID: 28835687 PMCID: PMC5569017 DOI: 10.1038/s41598-017-09574-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Accepted: 07/21/2017] [Indexed: 02/08/2023] Open
Abstract
Tumor protein p53 acts as a trans-activator that negatively regulates cell division by controlling a set of genes required for cell cycle regulation, making it a tumor suppressor in different types of tumors. Because the transcriptional activity of p53 plays an important role in the occurrence and development of tumors, reactivation of p53 transcriptional activity has been sought as a novel cancer therapeutic strategy. There is great interest in developing high-throughput assays to identify inhibitors of molecules that bind the transcription-activation domain of p53, especially for wt p53-containing tumors. In the present study, taking MDM2 as an example, a novel amplified luminescent proximity homogeneous assay (AlphaLISA) was modified from a binding competition assay to detect the interactions between the transcription-activation domain of p53 and its ligands. This assay can be adapted as a high-throughput assay for screening new inhibitors. A panel of well-known p53-MDM2 binding inhibitors was used to validate this method, and demonstrated its utility, sensitivity and robustness. In summary, we have developed a novel protein-protein interaction detection immunoassay that can be used in a high-throughput format to screen new drug candidates for reactivation of p53. This assay has been successfully validated through a series of p53-MDM2 binding inhibitors.
Collapse
Affiliation(s)
- Yufeng Xiong
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China
| | - Yingsong Wu
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China
| | - Shuhong Luo
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.,Department of Laboratory Medicine, School of Stomatology and Medicine, Foshan University, 5 Hebin Road, Chancheng District, Foshan, Guangdong Province, 528000, P. R. China
| | - Yang Gao
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China
| | - Yujing Xiong
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, Chinese University of Hong Kong, Shatin, 999077, Hong Kong
| | - Daxiang Chen
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China
| | - Hao Deng
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China
| | - Wenbo Hao
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China. .,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.
| | - Tiancai Liu
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China. .,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.
| | - Ming Li
- State Key Laboratory of Organ Failure, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China. .,Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.
| |
Collapse
|
15
|
Cohen N, Zahavy E, Zichel R, Fisher M. An internal standard approach for homogeneous TR-FRET immunoassays facilitates the detection of bacteria, biomarkers, and toxins in complex matrices. Anal Bioanal Chem 2016; 408:5179-88. [PMID: 27236318 DOI: 10.1007/s00216-016-9602-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Revised: 04/13/2016] [Accepted: 04/25/2016] [Indexed: 10/21/2022]
Abstract
The recent development of a homogeneous time-resolved Förster resonance energy transfer (TR-FRET) immunoassay enables one-step, rapid (minutes), and direct detection compared to the multistep, time-consuming (hours), heterogeneous ELISA-type immunoassays. The use of the time-resolved effect of a donor lanthanide complex with a delay time of microseconds and large Stokes shift enables the separation of positive signals from the background autofluorescence of the sample. However, this study shows that the sample matrices directly interfere with donor fluorescence and that interference cannot be eliminated by time-resolved settings alone. Moreover, the reduction in donor emission did not appear to be equivalent to the reduction in acceptor emission, resulting in incorrect FRET signal measurements. To overcome this limitation, an internal standard approach was developed using an isotype control antibody. This new approach was used to develop TR-FRET assays for rapid detection (15-30 min) of Bacillus anthracis spores and botulinum toxin (type E) in beverages, which are major concerns in bioterrorism involving deliberate food contamination. Additionally, we demonstrate the detection of B. anthracis-secreted protective antigen (PA) and the Yersinia pestis-secreted markers F1 and LcrV in blood cultures, which are early markers of bacteremia in infected hosts following a possible bioterror attack. The use of an internal standard enables the calculation of correct ΔF values without the need for an external standard. Thus, the use of the internal standard approach in homogeneous immunoassays facilitates the examination of any sample regardless of its origin, and therefore expands the applicability of TR-FRET assays for complex matrices.
Collapse
Affiliation(s)
- Noam Cohen
- Department of Biotechnology, Israel Institute for Biological Research, Ness-Ziona, 74100, Israel
| | - Eran Zahavy
- Department of Infectious Diseases, Israel Institute for Biological Research, Ness-Ziona, 74100, Israel
| | - Ran Zichel
- Department of Biotechnology, Israel Institute for Biological Research, Ness-Ziona, 74100, Israel
| | - Morly Fisher
- Department of Infectious Diseases, Israel Institute for Biological Research, Ness-Ziona, 74100, Israel.
| |
Collapse
|
16
|
High-sensitivity MALDI-TOF MS quantification of anthrax lethal toxin for diagnostics and evaluation of medical countermeasures. Anal Bioanal Chem 2015; 407:2847-58. [PMID: 25673244 PMCID: PMC4369318 DOI: 10.1007/s00216-015-8509-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2014] [Revised: 01/13/2015] [Accepted: 01/21/2015] [Indexed: 11/15/2022]
Abstract
Inhalation anthrax has a rapid progression and high fatality rate. Pathology and death from inhalation of Bacillus anthracis spores are attributed to the actions of secreted protein toxins. Protective antigen (PA) binds and imports the catalytic component lethal factor (LF), a zinc endoprotease, and edema factor (EF), an adenylyl cyclase, into susceptible cells. PA-LF is termed lethal toxin (LTx) and PA-EF, edema toxin. As the universal transporter for both toxins, PA is an important target for vaccination and immunotherapeutic intervention. However, its quantification has been limited to methods of relatively low analytic sensitivity. Quantification of LTx may be more clinically relevant than LF or PA alone because LTx is the toxic form that acts on cells. A method was developed for LTx-specific quantification in plasma using anti-PA IgG magnetic immunoprecipitation of PA and quantification of LF activity that co-purified with PA. The method was fast (<4 h total time to detection), sensitive at 0.033 ng/mL LTx in plasma for the fast analysis (0.0075 ng/mL LTx in plasma for an 18 h reaction), precise (6.3–9.9 % coefficient of variation), and accurate (0.1–12.7 %error; n ≥ 25). Diagnostic sensitivity was 100 % (n = 27 animal/clinical cases). Diagnostic specificity was 100 % (n = 141). LTx was detected post-antibiotic treatment in 6/6 treated rhesus macaques and 3/3 clinical cases of inhalation anthrax and as long as 8 days post-treatment. Over the course of infection in two rhesus macaques, LTx was first detected at 0.101 and 0.237 ng/mL at 36 h post-exposure and increased to 1147 and 12,107 ng/mL in late-stage anthrax. This demonstrated the importance of LTx as a diagnostic and therapeutic target. This method provides a sensitive, accurate tool for anthrax toxin detection and evaluation of PA-directed therapeutics. Method schematic for analysis of anthrax lethal toxin activity by ID-MALDI-TOF MS ![]()
Collapse
|
17
|
Du G, Yang X, Hu M, Hao C, Gu Y, Zhi X, Jiang WG, He J, Cheng S. Designing a novel high-throughput AlphaLISA assay to quantify plasma NHERF1 as a non-small cell lung cancer biomarker. RSC Adv 2015. [DOI: 10.1039/c5ra16502d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A novel amplified luminescent proximity homogeneous immunoassay (AlphaLISA) has been developed and validated for the quantification of NHERF1 in human plasma.
Collapse
Affiliation(s)
- Guifang Du
- Department of Biochemistry and Molecular Biology
- Capital Medical University
- Beijing 100069
- China
- Beijing Key Laboratory of Cancer & Metastasis Research
| | - Xiaomei Yang
- Department of Biochemistry and Molecular Biology
- Capital Medical University
- Beijing 100069
- China
- Beijing Key Laboratory of Cancer & Metastasis Research
| | - Mu Hu
- Beijing Key Laboratory of Cancer & Metastasis Research
- Capital Medical University
- Beijing 100069
- China
- Department of Thoracic Surgery
| | - Chengcheng Hao
- Department of Biochemistry and Molecular Biology
- Capital Medical University
- Beijing 100069
- China
- Beijing Key Laboratory of Cancer & Metastasis Research
| | - Yanan Gu
- Department of Biochemistry and Molecular Biology
- Capital Medical University
- Beijing 100069
- China
- Beijing Key Laboratory of Cancer & Metastasis Research
| | - Xiuyi Zhi
- Beijing Key Laboratory of Cancer & Metastasis Research
- Capital Medical University
- Beijing 100069
- China
- Department of Thoracic Surgery
| | - Wen G. Jiang
- Department of Biochemistry and Molecular Biology
- Capital Medical University
- Beijing 100069
- China
- Beijing Key Laboratory of Cancer & Metastasis Research
| | - Junqi He
- Department of Biochemistry and Molecular Biology
- Capital Medical University
- Beijing 100069
- China
- Beijing Key Laboratory of Cancer & Metastasis Research
| | - Shan Cheng
- Department of Biochemistry and Molecular Biology
- Capital Medical University
- Beijing 100069
- China
- Beijing Key Laboratory of Cancer & Metastasis Research
| |
Collapse
|
18
|
Tang J, Xiang L, Zhao F, Pan F, Wang S, Zhan X. Development of an Up-Conversion Homogenous Immunoassay for the Determination of Diethylstilbestrol in Water. ANAL LETT 2014. [DOI: 10.1080/00032719.2014.961605] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
19
|
Wang L, Han Y, Zhou S, Wang G, Guan X. Nanopore biosensor for label-free and real-time detection of anthrax lethal factor. ACS APPLIED MATERIALS & INTERFACES 2014; 6:7334-7339. [PMID: 24806593 PMCID: PMC4039345 DOI: 10.1021/am500749p] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Accepted: 05/07/2014] [Indexed: 05/29/2023]
Abstract
We report a label-free real-time nanopore sensing method for the detection of anthrax lethal factor, a component of the anthrax toxin, by using a complementary single-stranded DNA as a molecular probe. The method is rapid and sensitive: sub-nanomolar concentrations of the target anthrax lethal factor DNA could be detected in ∼1 min. Further, our method is selective, which can differentiate the target DNA from other single-stranded DNA molecules at the single-base resolution. This sequence-specific detection approach should find useful application in the development of nanopore sensors for the detection of other pathogens.
Collapse
Affiliation(s)
| | | | | | | | - Xiyun Guan
- Tel: 01-312-567-8922. Fax: 01-312-567-3494. E-mail:
| |
Collapse
|
20
|
Wang H, Nefzi A, Fields GB, Lakshmana MK, Minond D. AlphaLISA-based high-throughput screening assay to measure levels of soluble amyloid precursor protein α. Anal Biochem 2014; 459:24-30. [PMID: 24857774 DOI: 10.1016/j.ab.2014.05.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 04/23/2014] [Accepted: 05/11/2014] [Indexed: 01/14/2023]
Abstract
Activation of nonamyloidogenic processing of amyloid precursor protein (APP) has been hypothesized to be a viable approach for Alzheimer's disease drug discovery. However, until recently, the lack of HTS-compatible assay technologies precluded large scale screening efforts to discover molecules that potentiate nonamyloidogenic pathways. We have developed an HTS-compatible assay based on AlphaLISA technology that quantitatively detects soluble APPα (sAPPα), a marker of nonamyloidogenic processing of APP, released from live cells in low volume, 384-well plates. The assay exhibited good QC parameters (Z'>0.5, S/B>2). A pilot screen of 801 compounds yielded a novel chemotype that increased the release of sAPPα 2-fold at 5μM. These results suggest that the AlphaLISA-based HTS assay is robust and sensitive and can be used to screen large compound collections to discover molecules that potentiate the release of sAPPα. Additionally, we demonstrated that increase of APP processing by nonamyloidogenic pathways will result in decrease of release of amyloidogenic Aβ40 fragments.
Collapse
Affiliation(s)
- Hongjie Wang
- Torrey Pines Institute for Molecular Studies, 11350 SW Village Parkway, Port Saint Lucie, 34987 FL, USA
| | - Adel Nefzi
- Torrey Pines Institute for Molecular Studies, 11350 SW Village Parkway, Port Saint Lucie, 34987 FL, USA
| | - Gregg B Fields
- Torrey Pines Institute for Molecular Studies, 11350 SW Village Parkway, Port Saint Lucie, 34987 FL, USA
| | - Madepalli K Lakshmana
- Torrey Pines Institute for Molecular Studies, 11350 SW Village Parkway, Port Saint Lucie, 34987 FL, USA
| | - Dmitriy Minond
- Torrey Pines Institute for Molecular Studies, 11350 SW Village Parkway, Port Saint Lucie, 34987 FL, USA.
| |
Collapse
|
21
|
Cohen N, Mechaly A, Mazor O, Fisher M, Zahavy E. Rapid Homogenous Time-Resolved Fluorescence (HTRF) Immunoassay for Anthrax Detection. J Fluoresc 2014; 24:795-801. [DOI: 10.1007/s10895-014-1354-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 01/27/2014] [Indexed: 10/25/2022]
|
22
|
Farrow B, Hong SA, Romero EC, Lai B, Coppock MB, Deyle KM, Finch AS, Stratis-Cullum DN, Agnew HD, Yang S, Heath JR. A chemically synthesized capture agent enables the selective, sensitive, and robust electrochemical detection of anthrax protective antigen. ACS NANO 2013; 7:9452-9460. [PMID: 24063758 DOI: 10.1021/nn404296k] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
We report on a robust and sensitive approach for detecting protective antigen (PA) exotoxin from Bacillus anthracis in complex media. A peptide-based capture agent against PA was developed by improving a bacteria display-developed peptide into a highly selective biligand through in situ click screening against a large, chemically synthesized peptide library. This biligand was coupled with an electrochemical enzyme-linked immunosorbent assay utilizing nanostructured gold electrodes. The resultant assay yielded a limit of detection of PA of 170 pg/mL (2.1 pM) in buffer, with minimal sensitivity reduction in 1% serum. The powdered capture agent could be stably stored for several days at 65 °C, and the full electrochemical biosensor showed no loss of performance after extended storage at 40 °C. The engineered stability and specificity of this assay should be extendable to other cases in which biomolecular detection in demanding environments is required.
Collapse
Affiliation(s)
- Blake Farrow
- Department of Applied Physics and Materials Science, and ‡Division of Chemistry and Chemical Engineering, California Institute of Technology , 1200 East California Boulevard, Pasadena, California 91125, United States
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|