Rasheed M, Perveen S, Qamar S. Theoretical Investigation of the Nonlinear General Rate Model with the Bi-Langmuir Adsorption Isotherm Using Core-Shell Adsorbents. ACS OMEGA 2023; 8:43964-43977. [PMID: 38027365 PMCID: PMC10666139 DOI: 10.1021/acsomega.3c06023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 10/27/2023] [Accepted: 10/27/2023] [Indexed: 12/01/2023]
Abstract
Core-shell particles enable the separation of intricate mixtures in a highly efficient and rapid manner. The porous shell particles increased the separation efficiency with expedited flow rates due to an abatement in the pore volume accessible for longitudinal diffusion and a decrease in diffusion path length. This study focuses on the numerical approximation of a nonlinear isothermal general rate model applied to stationary bed columns that are replete with inert core adsorbents featuring double adsorption sites. The transport of solute in heterogeneous porous media can be modeled by a nonlinear convection acquiescent partial differential equation system together with a specific nonlinear algebraic relation: the bi-Langmuir adsorption isotherm. Therefore, it is important to develop accurate and reliable numerical techniques that can perform accurate numerical simulations of these models. We extended and implemented a second-order, semidiscrete, high-resolution finite volume method to simulate the governing equations of the model. Single solute flow and multi component mixture flows are assessed through a series of numerical experiments to theoretically illustrate the repercussions of intraparticle diffusion, film mass resistance, axial dispersion, and the size of the inert core radius upon simulated elution curves. Standard performance criteria are assessed to determine the optimal core radius fraction range for optimizing the separation performance.
Collapse
Affiliation(s)
- Muhammad
Afraz Rasheed
- Department
of Mathematics, Air University, PAF Complex, Sector E-9, Islamabad 44230, Pakistan
| | - Sadia Perveen
- Department
of Mathematics, Air University, PAF Complex, Sector E-9, Islamabad 44230, Pakistan
| | - Shamsul Qamar
- Department
of Mathematics, COMSATS University, Park Road, Islamabad 45550, Pakistan
| |
Collapse
|
2
|
Ibrahim AE, El Gohary NA, Aboushady D, Samir L, Karim SEA, Herz M, Salman BI, Al-Harrasi A, Hanafi R, El Deeb S. Recent advances in chiral selectors immobilization and chiral mobile phase additives in liquid chromatographic enantio-separations: A review. J Chromatogr A 2023; 1706:464214. [PMID: 37506464 DOI: 10.1016/j.chroma.2023.464214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/10/2023] [Accepted: 07/11/2023] [Indexed: 07/30/2023]
Abstract
For decades now, the separation of chiral enantiomers of drugs has been gaining the interest and attention of researchers. In 1991, the first guidelines for development of chiral drugs were firstly released by the US-FDA. Since then, the development in chromatographic enantioseparation tools has been fast and variable, aiming at creating a suitable environment where the physically and chemically identical enantiomers can be separated. Among those tools, the immobilization of chiral selectors (CS) on different stationary phases and the chiral mobile phase additives (CMPA) which have been progressed and studied extensively. This review article highlights the major advances in immobilization of CS together with their different recognition mechanisms as well as CMPA as a cheaper and successful alternative for chiral stationary phases. Moreover, the role of molecular modeling tool as a pre-step in the choice of CS for evaluating possible interactions with different ligands has been pointed up. Illustrations of reported methods and updates for immobilized CS and CMPA have been included.
Collapse
Affiliation(s)
- Adel Ehab Ibrahim
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Port-Said University, Port-Said 42511, Egypt; Natural and Medical Sciences Research Center, University of Nizwa, P.O. Box 33, Birkat Al Mauz, Nizwa 616, Sultanate of Oman
| | - Nesrine Abdelrehim El Gohary
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt
| | - Dina Aboushady
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt
| | - Liza Samir
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt
| | - Shereen Ekram Abdel Karim
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt
| | - Magy Herz
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt
| | - Baher I Salman
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Assiut Branch, Assiut, 71524, Egypt
| | - Ahmed Al-Harrasi
- Natural and Medical Sciences Research Center, University of Nizwa, P.O. Box 33, Birkat Al Mauz, Nizwa 616, Sultanate of Oman
| | - Rasha Hanafi
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt
| | - Sami El Deeb
- Institute of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Braunschweig 38092, Germany; Institute of Pharmacy, Freie Universität Berlin, Königin-Luise-Str. 2+4, 14195 Berlin, Germany.
| |
Collapse
|
3
|
Gong X, Chen W, Zhang K, Li T, Song Q. Serially coupled column liquid chromatography: An alternative separation tool. J Chromatogr A 2023; 1706:464278. [PMID: 37572536 DOI: 10.1016/j.chroma.2023.464278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/20/2023] [Accepted: 08/02/2023] [Indexed: 08/14/2023]
Abstract
Despite the rapid development of liquid chromatography (LC) in recent decades, it remains a challenge to achieve the desired chromatographic separation of complex matrices using a single column. Multi-column LC techniques, particularly serially coupled column LC (SCC-LC), have emerged as a promising solution to overcome this challenge. While more attention has been focused on heart-cutting or comprehensive two-dimensional LC, reviews specifically focusing on SCC-LC, which offers advantages in terms of precision and facile instrumentation, are scarce. Here, our concerns are devoted to the progress summary regarding the instrumentation and applications of SCC-LC. Emphasis is placed on column selection aiming to enlarge peak capacity, selectivity, or both through the optimization of combination types (e.g. RPLC-RPLC, -RPLC-HILIC, and achiral-chiral LC), connection devices (e.g. zero dead volume connector, tubing, and T-type connector), elution program (i.e. isocratic or gradient) and detectors (e.g. mass spectrometer, ultraviolet detector, and fluorescence detector). The application of SCC-LC in pharmaceutical, biological, environmental, and food fields is also reviewed, and future perspectives and potential directions for SCC-LC are discussed. We envision that the review can give meaningful information to analytical scientists when facing heavy chromatographic separation tasks for complicated matrices.
Collapse
Affiliation(s)
- Xingcheng Gong
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Wei Chen
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Ke Zhang
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Ting Li
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Qingqing Song
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China.
| |
Collapse
|
4
|
Česla P, Hájek T, Urban J, Holčapek M. Liquid chromatography at the university of pardubice: a tribute to Professor Pavel Jandera. J Sep Sci 2022; 45:3214-3231. [PMID: 35932491 DOI: 10.1002/jssc.202200618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/03/2022] [Accepted: 08/03/2022] [Indexed: 11/12/2022]
Abstract
Pavel Jandera was a world-leading analytical chemist who devoted his entire professional life to research in the field of high-performance liquid chromatography. During all his scientific career, he worked at the Department of Analytical Chemistry at the University of Pardubice, Czech Republic. His greatest contribution to the field of liquid chromatography was the introduction of a comprehensive theory of liquid chromatography with programmed elution conditions. He was also involved in the research of gradient elution techniques in preparative chromatography, modeling of retention and selectivity in various phase systems, preparation of organic monolithic microcolumns and, last but not least, in the development of theory and practical applications of two-dimensional liquid chromatography, mainly in the comprehensive form. In this review article, we have tried to capture the highlights of his scientific career and provide the readers with a detailed overview of Pavel Jandera's contribution to the evolution of separation sciences. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Petr Česla
- Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czech Republic
| | - Tomáš Hájek
- Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czech Republic
| | - Jiří Urban
- Faculty of Science, Department of Chemistry, Masaryk University, Kamenice 5, Brno, CZ-62500, Czech Republic
| | - Michal Holčapek
- Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czech Republic
| |
Collapse
|
5
|
Si H, Wang Q, Guo Y, Zhao Y, Li H, Li S, Wang S, Zhu B. Functionalized monolithic columns: Recent advancements and their applications for high-efficiency separation and enrichment in food and medicine. Front Chem 2022; 10:951649. [PMID: 35991596 PMCID: PMC9388943 DOI: 10.3389/fchem.2022.951649] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 07/06/2022] [Indexed: 11/20/2022] Open
Abstract
The chromatographic column is the core of a high-performance liquid chromatography (HPLC) system, and must have excellent separation efficiency and selectivity. Therefore, functional modification materials for monolithic columns have been rapidly developed. This study is a systematic review of the recently reported functionalized monolithic columns. In particular, the study reviews the types of functional monomers under different modification conditions, as well as the separation and detection techniques combined with chromatography, and their development prospects. In addition, the applications of functionalized monolithic columns in food analysis, biomedicine, and the analysis of active ingredient of Chinese herbal medicines in recent years are also discussed. Also reviewed are the functionalized monolithic columns for qualitative and quantitative analysis. It provided a reference for further development and application of organic polymer monolithic columns.
Collapse
Affiliation(s)
- Helong Si
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
| | - Quan Wang
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
- Hebei Forage Microbial Technology Innovation Center, Baoding, Hebei, China
- Hebei Agriculture Waste Resource Utilization Engineering Research Center, Baoding, Hebei, China
- *Correspondence: Quan Wang,
| | - Yuanyuan Guo
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
- Hebei Forage Microbial Technology Innovation Center, Baoding, Hebei, China
- Hebei Agriculture Waste Resource Utilization Engineering Research Center, Baoding, Hebei, China
| | - Yuxin Zhao
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
- Hebei Forage Microbial Technology Innovation Center, Baoding, Hebei, China
- Hebei Agriculture Waste Resource Utilization Engineering Research Center, Baoding, Hebei, China
| | - Hongya Li
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
- Hebei Forage Microbial Technology Innovation Center, Baoding, Hebei, China
- Hebei Agriculture Waste Resource Utilization Engineering Research Center, Baoding, Hebei, China
| | - Shuna Li
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
- Hebei Forage Microbial Technology Innovation Center, Baoding, Hebei, China
- Hebei Agriculture Waste Resource Utilization Engineering Research Center, Baoding, Hebei, China
| | - Shuxiang Wang
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
- Hebei Forage Microbial Technology Innovation Center, Baoding, Hebei, China
- Hebei Agriculture Waste Resource Utilization Engineering Research Center, Baoding, Hebei, China
| | - Baocheng Zhu
- College of Life Science, Hebei Agricultural University, Baoding, Hebei, China
- Hebei Forage Microbial Technology Innovation Center, Baoding, Hebei, China
- Hebei Agriculture Waste Resource Utilization Engineering Research Center, Baoding, Hebei, China
| |
Collapse
|
6
|
Chiral Monolithic Silica-Based HPLC Columns for Enantiomeric Separation and Determination: Functionalization of Chiral Selector and Recognition of Selector-Selectand Interaction. Molecules 2021; 26:molecules26175241. [PMID: 34500675 PMCID: PMC8434329 DOI: 10.3390/molecules26175241] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 08/25/2021] [Accepted: 08/26/2021] [Indexed: 11/25/2022] Open
Abstract
This review draws attention to the use of chiral monolithic silica HPLC columns for the enantiomeric separation and determination of chiral compounds. Properties and advantages of monolithic silica HPLC columns are also highlighted in comparison to conventional particle-packed, fused-core, and sub-2-µm HPLC columns. Nano-LC capillary monolithic silica columns as well as polymeric-based and hybrid-based monolithic columns are also demonstrated to show good enantioresolution abilities. Methods for introducing the chiral selector into the monolithic silica column in the form of mobile phase additive, by encapsulation and surface coating, or by covalent functionalization are described. The application of molecular modeling methods to elucidate the selector–selectand interaction is discussed. An application for enantiomeric impurity determination is also considered.
Collapse
|
7
|
Horváth S, Gritti F, Horváth K. Theoretical study of the efficiency of liquid chromatography columns with particle size gradient. J Chromatogr A 2021; 1651:462331. [PMID: 34153736 DOI: 10.1016/j.chroma.2021.462331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 06/04/2021] [Accepted: 06/06/2021] [Indexed: 11/17/2022]
Abstract
Modern analytical applications of liquid chromatography require more and more efficient columns. In this work, the possibility of utilizing particle size gradient in the chromatographic column was studied by a theoretical approach. In the course of our work three different scenarios of particle size gradients were considered with different shapes (linear, convex and concave). The evolution of bandwidth inside the column was plotted for each scenario. As a reference point, the bandwidth of the uniform column was used, which had the same pressure drop as the non-uniform column. According to our calculations, in isocratic elution mode, the non-uniform column does not offer any advantage compared to the uniform column, regardless the type of the particle size gradient. In gradient elution mode, however, extra band compression occurs was found. For negative particle size gradients, the final physical bandwidth was found to be approximately 1-4 % smaller than for uniform columns. This slight gain in efficiency in terms of bandwidth compression can be expanded to 5-8 % by the optimization of the limiting particle sizes. These optimized results are obtained when the final particle size is approximately 40% of the initial particle diameter.
Collapse
Affiliation(s)
- Szabolcs Horváth
- Research Group of Analytical Chemistry, University of Pannonia, Egyetem utca 10, Veszprém H-8200, Hungary
| | - Fabrice Gritti
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States
| | - Krisztián Horváth
- Research Group of Analytical Chemistry, University of Pannonia, Egyetem utca 10, Veszprém H-8200, Hungary
| |
Collapse
|
8
|
Kamei R, Hosomi T, Kanao E, Kanai M, Nagashima K, Takahashi T, Zhang G, Yasui T, Terao J, Otsuka K, Baba Y, Kubo T, Yanagida T. Rational Strategy for Space-Confined Seeded Growth of ZnO Nanowires in Meter-Long Microtubes. ACS APPLIED MATERIALS & INTERFACES 2021; 13:16812-16819. [PMID: 33784465 DOI: 10.1021/acsami.0c22709] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Seeded crystal growths of nanostructures within confined spaces offer an interesting approach to design chemical reaction spaces with tailored inner surface properties. However, such crystal growth within confined spaces tends to be inherently difficult as the length increases as a result of confinement effects. Here, we demonstrate a space-confined seeded growth of ZnO nanowires within meter-long microtubes of 100 μm inner diameter with the aspect ratio of up to 10 000, which had been unattainable to previous methods of seeded crystal growths. ZnO nanowires could be grown via seeded hydrothermal crystal growth for relatively short microtubes below the length of 40 mm, while any ZnO nanostructures were not observable at all for longer microtubes above 60 mm with the aspect ratio of 600. Microstructural and mass spectrometric analysis revealed that a conventional seed layer formation using zinc acetate is unfeasible within the confined space of long microtubes as a result of the formation of detrimental residual Zn complex compounds. To overcome this space-confined issue, a flow-assisted seed layer formation is proposed. This flow-assisted method enables growth of spatially uniform ZnO nanowires via removing residual compounds even for 1 m long microtubes with the aspect ratio of up to 10 000. Finally, the applicably of ZnO-nanowire-decorated long microtubes for liquid-phase separations was demonstrated.
Collapse
Affiliation(s)
- Ryoma Kamei
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
- Institute for Materials Chemistry and Engineering, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka 816-8580, Japan
| | - Takuro Hosomi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
- Precursory Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Eisuke Kanao
- Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606-8501, Japan
- National Institutes of Biomedical Innovation, Health and Nutrition, Ibaraki, Osaka 567-0085, Japan
| | - Masaki Kanai
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
- Institute for Materials Chemistry and Engineering, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka 816-8580, Japan
| | - Kazuki Nagashima
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
- Precursory Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Tsunaki Takahashi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
- Precursory Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Guozhu Zhang
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
| | - Takao Yasui
- Precursory Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
- Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
| | - Jun Terao
- Department of Basic Science, Graduate School of Art and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo 153-8902, Japan
| | - Koji Otsuka
- Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan
| | - Yoshinobu Baba
- Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
| | - Takuya Kubo
- Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan
| | - Takeshi Yanagida
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
- Institute for Materials Chemistry and Engineering, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka 816-8580, Japan
| |
Collapse
|
9
|
Saad MN, Essam HM, Elzanfaly ES, Amer SM. A Two-Step Optimization Approach: Validated RP-HPLC Method for Determination of Gatifloxacin and Dexamethasone in Ophthalmic Formulation. J Chromatogr Sci 2020; 58:504-510. [PMID: 32280954 DOI: 10.1093/chromsci/bmaa013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 02/10/2020] [Accepted: 02/25/2020] [Indexed: 01/02/2023]
Abstract
The growing technology of stationary phase chemistry has a great impact on the chromatographic system performance and analysis economics. In this context, a simple rapid reversed phase high-performance liquid chromatography method development is presented for the analysis of gatifloxacin (GFN) and dexamethasone sodium phosphate (DSP) in their ophthalmic formulation. A two-step optimization approach has been conducted using optimum chromatographic conditions as well as proper selection of stationary phase. The chromatographic separation was carried out using sodium phosphate buffer pH 3.0 ± 0.1 and acetonitrile 72:28 v/v, respectively, with flow rate 1 mL min-1 and simultaneous detection at 243 nm. Three different column technologies were investigated at the optimum set of the chromatographic conditions: Xbridge® bridged ethylene hybrid silica, Kinetex™ Core-Shell and the Onyx™ Monolithic stationary phase. The monolithic column has shown better chromatographic separation, based on system suitability testing as well as shorter analysis time and sensitivity. The proposed method was validated according to International Conference on Harmonization guidelines. The linearity was achieved for GFN and DSP in the range 0.58-120 μg mL-1 and 0.50-120 μg mL-1, respectively, with acceptable accuracy, precision and selectivity.
Collapse
Affiliation(s)
- Martin N Saad
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| | - Hebatallah M Essam
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| | - Eman S Elzanfaly
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| | - Sawsan M Amer
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| |
Collapse
|
10
|
Wang L, Marcus RK. Polypropylene capillary-channeled polymer fiber column as the second dimension in a comprehensive two-dimensional RP × RP analysis of a mixture of intact proteins. Anal Bioanal Chem 2020; 412:2963-2979. [DOI: 10.1007/s00216-020-02539-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 02/17/2020] [Accepted: 02/20/2020] [Indexed: 10/24/2022]
|
11
|
Lv W, Shi X, Wang S, Xu G. Multidimensional liquid chromatography-mass spectrometry for metabolomic and lipidomic analyses. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.11.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
12
|
Haidar Ahmad IA, Chen W, Halsey HM, Klapars A, Limanto J, Pirrone GF, Nowak T, Bennett R, Hartman R, Makarov AA, Mangion I, Regalado EL. Multi-column ultra-high performance liquid chromatography screening with chaotropic agents and computer-assisted separation modeling enables process development of new drug substances. Analyst 2019; 144:2872-2880. [DOI: 10.1039/c8an02499e] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Streamlined workflow for method development and optimization.
Collapse
Affiliation(s)
| | - Wenyong Chen
- Process Research and Development
- MRL
- Merck & Co
- Inc
- Rahway
| | | | - Artis Klapars
- Process Research and Development
- MRL
- Merck & Co
- Inc
- Rahway
| | - John Limanto
- Process Research and Development
- MRL
- Merck & Co
- Inc
- Rahway
| | | | - Timothy Nowak
- Process Research and Development
- MRL
- Merck & Co
- Inc
- Rahway
| | | | | | | | - Ian Mangion
- Process Research and Development
- MRL
- Merck & Co
- Inc
- Rahway
| | | |
Collapse
|
13
|
Zhu Z, Chen H, Ren J, Lu JJ, Gu C, Lynch KB, Wu S, Wang Z, Cao C, Liu S. Two-dimensional chromatographic analysis using three second-dimension columns for continuous comprehensive analysis of intact proteins. Talanta 2018; 179:588-593. [DOI: 10.1016/j.talanta.2017.11.060] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 11/22/2017] [Accepted: 11/26/2017] [Indexed: 11/16/2022]
|
14
|
Jandera P, Hájek T, Šromová Z. Mobile phase effects in reversed-phase and hydrophilic interaction liquid chromatography revisited. J Chromatogr A 2018; 1543:48-57. [PMID: 29486886 DOI: 10.1016/j.chroma.2018.02.043] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 02/02/2018] [Accepted: 02/20/2018] [Indexed: 11/24/2022]
Abstract
Correct adjustment of the mobile phase is equally important as the selection of the appropriate column for the separation of polar compounds in LC. Both solvophobic and selective polar interactions control the retention in the Reversed Phase and Hydrophilic Interaction modes. The retention models describing the effects of the volume fraction of the strong eluent component in binary mobile phases on the sample retention factors apply in a limited mobile phase composition range. We introduced a three-parameter retention model, which provides improved prediction of retention over a broad mobile phase range, under isocratic and gradient elution conditions. The model does not imply any assumptions concerning either adsorption or partition distribution mechanism, but allows estimating retention in pure strong and in pure weak mobile phase components. The experimental retention data for phenolic acids and flavones on several core-shell columns with different types of stationary phases agree with the theory. Many polar columns with important structural hydrophobic moieties show dual retention mechanism, (Reversed Phase in water rich mobile phases and Hydrophilic Interaction at high acetonitrile concentrations). It is possible to select the mobile phase compositions in each of the two modes for separations of samples containing compounds largely differing in polarity. The three-parameter model describes the retention in each mode, with separately determined best-fit parameters. We applied the two-mode model to the retention data of sulfonamides and benzoic acid related compounds on a new polymethacrylate zwitterionic monolithic micro-column.
Collapse
Affiliation(s)
- Pavel Jandera
- University of Pardubice, Department of Analytical Chemistry, Studentská 573, CZ-53210 Pardubice, Czech Republic
| | - Tomáš Hájek
- University of Pardubice, Department of Analytical Chemistry, Studentská 573, CZ-53210 Pardubice, Czech Republic
| | - Zuzana Šromová
- University of Pardubice, Department of Analytical Chemistry, Studentská 573, CZ-53210 Pardubice, Czech Republic
| |
Collapse
|
15
|
Catani M, Felletti S, Ismail OH, Gasparrini F, Pasti L, Marchetti N, De Luca C, Costa V, Cavazzini A. New frontiers and cutting edge applications in ultra high performance liquid chromatography through latest generation superficially porous particles with particular emphasis to the field of chiral separations. Anal Bioanal Chem 2018; 410:2457-2465. [DOI: 10.1007/s00216-017-0842-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 12/05/2017] [Accepted: 12/15/2017] [Indexed: 11/28/2022]
|
16
|
Timmer N, Scherpenisse P, Hermens JLM, Droge STJ. Evaluating solid phase (micro-) extraction tools to analyze freely ionizable and permanently charged cationic surfactants. Anal Chim Acta 2017; 1002:26-38. [PMID: 29306411 DOI: 10.1016/j.aca.2017.11.051] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 11/15/2017] [Accepted: 11/19/2017] [Indexed: 10/18/2022]
Abstract
Working with and analysis of cationic surfactants can be problematic since aqueous concentrations are difficult to control, both when taking environmental aqueous samples as well as performing laboratory work with spiked concentrations. For a selection of 32 amine based cationic surfactants (including C8- to C18-alkylamines, C14-dialkyldimethylammonium, C8-tetraalkylammonium, benzalkonium and pyridinium compounds), the extraction from aqueous samples was studied in detail. Aqueous concentrations were determined using solid phase extraction (SPE; 3 mL/60 mg Oasis WCX-SPE cartridges) with recoveries of ≥80% for 30 compounds, and ≥90% for 16 compounds. Sorption to glassware was evaluated in 120 mL flasks, 40 mL vials and 1.5 mL autosampler vials, using 15 mM NaCl, where the glass binding of simple primary amines and quaternary ammonium compounds increased with alkyl chain length. Sorption to the outside of pipette tips (≤20% of total amount in solution) when sampling aqueous solutions may interfere with accurate measurements. Polyacrylate solid phase microextraction (PA-SPME) fibers with two coating thicknesses (7 and 35 μm) were tested as potential extraction devices. The uptake kinetics, pH-dependence and influence of ionic strength on sorption to PA fibers were studied. Changing medium from 100 mM Na+ to 10 mM Ca2+ decreases Kfw with one order of magnitude. Results indicate that for PA-SPME neutral amines are absorbed rather than adsorbed, although the exact sorption mechanism remains to be elucidated. Further research remains necessary to establish a definitive applicability domain for PA-SPME. However, results indicate that alkyl chain lengths ≥14 carbon atoms and multiple alkyl chains become problematic. A calibration curve should always be measured together with the samples. In conclusion, it seems that for amine based surfactants PA-SPME does not provide the reliability and reproducibility necessary for precise sorption experiments, specifically for alkyl chain lengths beyond 12 carbon atoms.
Collapse
Affiliation(s)
- Niels Timmer
- Institute for Risk Assessment Sciences, Utrecht University, P.O. Box 80177, 3508 TD Utrecht, The Netherlands
| | - Peter Scherpenisse
- Institute for Risk Assessment Sciences, Utrecht University, P.O. Box 80177, 3508 TD Utrecht, The Netherlands
| | - Joop L M Hermens
- Institute for Risk Assessment Sciences, Utrecht University, P.O. Box 80177, 3508 TD Utrecht, The Netherlands
| | - Steven T J Droge
- Institute for Risk Assessment Sciences, Utrecht University, P.O. Box 80177, 3508 TD Utrecht, The Netherlands; Institute for Biodiversity and Ecosystem Dynamics, Department Freshwater and Marine Ecology, P.O. Box 94248, 1090 GE Amsterdam, The Netherlands.
| |
Collapse
|
17
|
Jandera P, Hájek T. Mobile phase effects on the retention on polar columns with special attention to the dual hydrophilic interaction-reversed-phase liquid chromatography mechanism, a review. J Sep Sci 2017; 41:145-162. [DOI: 10.1002/jssc.201701010] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 10/04/2017] [Accepted: 10/04/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Pavel Jandera
- Department of Analytical Chemistry; Faculty of Chemical Technology; University of Pardubice; Pardubice Czech Republic
| | - Tomáš Hájek
- Department of Analytical Chemistry; Faculty of Chemical Technology; University of Pardubice; Pardubice Czech Republic
| |
Collapse
|
18
|
Al-Massaedh “AA, Pyell U. Mixed-Mode Acrylamide-Based Continuous Beds Bearing tert-Butyl Groups for Capillary Electrochromatography Synthesized Via Complexation of N-tert-Butylacrylamide with a Water-Soluble Cyclodextrin. Part II: Effect of Capillary Size and Polymerization Conditions on Morphology and Chromatographic Efficiency. Chromatographia 2017. [DOI: 10.1007/s10337-017-3408-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
19
|
Fast gradient HPLC/MS separation of phenolics in green tea to monitor their degradation. Food Chem 2017; 237:471-480. [PMID: 28764022 DOI: 10.1016/j.foodchem.2017.05.133] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 05/18/2017] [Accepted: 05/22/2017] [Indexed: 11/23/2022]
Abstract
The degradation of catechins and other phenolics in green tea infusions were monitored using fast HPLC/MS separation. The final separation was performed within 2.5min using Ascentis Express C18 column (50mm×2.1mm i.d.) packed with 2μm porous shell particles. Degradation was studied in relation to the temperature of water (70, 80, 90°C) and the standing time of the infusion (up to 6h). Along with chromatographic separation, the antioxidant properties of the infusions were monitored using two spectrophotometric methods. During staying of green tea infusion, the degradation of some catechins probably to gallic acid was observed. Finally, the influence of tea bag storage on antioxidant properties of green tea was evaluated. Rapid degradation of antioxidants after 3weeks was observed. The principal component analysis, factor analysis and discriminant analysis were used for the statistical evaluation of obtained experimental data.
Collapse
|
20
|
Jandera P, Janás P. Recent advances in stationary phases and understanding of retention in hydrophilic interaction chromatography. A review. Anal Chim Acta 2017; 967:12-32. [DOI: 10.1016/j.aca.2017.01.060] [Citation(s) in RCA: 180] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 01/05/2017] [Accepted: 01/06/2017] [Indexed: 12/01/2022]
|
21
|
Catani M, Ismail OH, Gasparrini F, Antonelli M, Pasti L, Marchetti N, Felletti S, Cavazzini A. Recent advancements and future directions of superficially porous chiral stationary phases for ultrafast high-performance enantioseparations. Analyst 2017; 142:555-566. [DOI: 10.1039/c6an02530g] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
This review focuses on the use of superficially porous particles (SPPs) as chiral stationary phases for ultra-high performance liquid enantioseparations.
Collapse
Affiliation(s)
- Martina Catani
- Dept. of Chemistry and Pharmaceutical Sciences
- University of Ferrara
- 44121 Ferrara
- Italy
| | - Omar H. Ismail
- Department of Drug Chemistry and Technology
- “Sapienza” Università di Roma
- 00185 Roma
- Italy
| | - Francesco Gasparrini
- Department of Drug Chemistry and Technology
- “Sapienza” Università di Roma
- 00185 Roma
- Italy
| | - Michela Antonelli
- Department of Drug Chemistry and Technology
- “Sapienza” Università di Roma
- 00185 Roma
- Italy
| | - Luisa Pasti
- Dept. of Chemistry and Pharmaceutical Sciences
- University of Ferrara
- 44121 Ferrara
- Italy
| | - Nicola Marchetti
- Dept. of Chemistry and Pharmaceutical Sciences
- University of Ferrara
- 44121 Ferrara
- Italy
| | - Simona Felletti
- Dept. of Chemistry and Pharmaceutical Sciences
- University of Ferrara
- 44121 Ferrara
- Italy
| | - Alberto Cavazzini
- Dept. of Chemistry and Pharmaceutical Sciences
- University of Ferrara
- 44121 Ferrara
- Italy
| |
Collapse
|
22
|
Česla P, Křenková J. Fraction transfer process in on-line comprehensive two-dimensional liquid-phase separations. J Sep Sci 2016; 40:109-123. [DOI: 10.1002/jssc.201600921] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Revised: 11/15/2016] [Accepted: 11/20/2016] [Indexed: 01/19/2023]
Affiliation(s)
- Petr Česla
- Faculty of Chemical Technology, Department of Analytical Chemistry; University of Pardubice; Pardubice Czech Republic
| | - Jana Křenková
- Institute of Analytical Chemistry of the CAS; v.v.i.; Brno Czech Republic
| |
Collapse
|
23
|
Al-Massaedh “AA, Pyell U. Mixed-mode acrylamide-based continuous beds bearing tert -butyl groups for capillary electrochromatography synthesized via complexation of N - tert -butylacrylamide with a water-soluble cyclodextrin. Part I: Retention properties. J Chromatogr A 2016; 1477:114-126. [DOI: 10.1016/j.chroma.2016.11.036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2016] [Revised: 11/08/2016] [Accepted: 11/20/2016] [Indexed: 10/20/2022]
|
24
|
D'Addio SM, Bothe JR, Neri C, Walsh PL, Zhang J, Pierson E, Mao Y, Gindy M, Leone A, Templeton AC. New and Evolving Techniques for the Characterization of Peptide Therapeutics. J Pharm Sci 2016; 105:2989-3006. [DOI: 10.1016/j.xphs.2016.06.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 06/06/2016] [Accepted: 06/17/2016] [Indexed: 01/31/2023]
|
25
|
Schenk DJ, Welch CJ, Antonucci V. Evaluation of C18 monolithic columns for radiochemical purity measurement. J Labelled Comp Radiopharm 2016; 59:391-7. [DOI: 10.1002/jlcr.3422] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 05/06/2016] [Accepted: 06/05/2016] [Indexed: 11/09/2022]
Affiliation(s)
- David J. Schenk
- Process and Analytical Chemistry; Merck Research Laboratories; 126 E. Lincoln Avenue Rahway NJ 07065 USA
| | - Christopher J. Welch
- Process and Analytical Chemistry; Merck Research Laboratories; 126 E. Lincoln Avenue Rahway NJ 07065 USA
| | - Vincent Antonucci
- Process and Analytical Chemistry; Merck Research Laboratories; 126 E. Lincoln Avenue Rahway NJ 07065 USA
| |
Collapse
|
26
|
Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review. Anal Chim Acta 2016; 923:1-23. [DOI: 10.1016/j.aca.2016.03.040] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 03/17/2016] [Accepted: 03/21/2016] [Indexed: 01/22/2023]
|
27
|
Franco MS, Padovan RN, Fumes BH, Lanças FM. An overview of multidimensional liquid phase separations in food analysis. Electrophoresis 2016; 37:1768-83. [PMID: 27030380 DOI: 10.1002/elps.201600028] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Revised: 03/14/2016] [Accepted: 03/15/2016] [Indexed: 01/06/2023]
Abstract
Food safety is a priority public health concern that demands analytical methods capable to detect low concentration level of contaminants (e.g. pesticides and antibiotics) in different food matrices. Due to the high complexity of these matrices, a sample preparation step is in most cases mandatory to achieve satisfactory results being usually tedious, lengthy, and prone to the introduction of errors. For this reason, many research groups have focused efforts on the development of online systems capable to do the cleanup, concentration, and separation steps at once through multidimensional separation techniques (MDS). Among several possible setups, the most popular are the multidimensional chromatographic techniques (MDC) that consist in combining more than one mobile and/or stationary phase to provide a satisfactory separation. In the present review, we selected a variety of multidimensional separation systems used for food contaminant analysis in order to discuss the instrumentation aspects, the concept of orthogonality, column approaches used in these systems, and new materials that can be used in these columns. Selected classes of contaminants present in food matrices are introduced and discussed as example of the potential applications of multidimensional liquid phase separation techniques in food safety.
Collapse
Affiliation(s)
- Maraíssa Silva Franco
- Institute of Chemistry of São Carlos, University of São Paulo, Sao Carlos, SP, Brasil
| | | | - Bruno Henrique Fumes
- Institute of Chemistry of São Carlos, University of São Paulo, Sao Carlos, SP, Brasil
| | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos, University of São Paulo, Sao Carlos, SP, Brasil
| |
Collapse
|
28
|
Automated dual two-dimensional liquid chromatography approach for fast acquisition of three-dimensional data using combinations of zwitterionic polymethacrylate and silica-based monolithic columns. J Chromatogr A 2016; 1446:91-102. [DOI: 10.1016/j.chroma.2016.04.007] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 03/31/2016] [Accepted: 04/03/2016] [Indexed: 11/23/2022]
|
29
|
Analytical advances in pharmaceutical impurity profiling. Eur J Pharm Sci 2016; 87:118-35. [DOI: 10.1016/j.ejps.2015.12.007] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Revised: 11/14/2015] [Accepted: 12/05/2015] [Indexed: 01/11/2023]
|
30
|
Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications. Int J Anal Chem 2016; 2016:3189724. [PMID: 27143972 PMCID: PMC4842074 DOI: 10.1155/2016/3189724] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2015] [Accepted: 03/08/2016] [Indexed: 11/18/2022] Open
Abstract
The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large amount of samples must be analyzed fast using reliable and solvent-saving apparatus. The literature hereby described shows how the outstanding performances provided by core-shell particles column on a traditional HPLC instruments are comparable to those obtained with a costly UHPLC instrumentation, making this novel column a promising key tool in food analysis.
Collapse
|
31
|
Development of a high-performance liquid chromatography method based on a core–shell column approach for the rapid determination of multiclass polyphenols in grape pomaces. Food Chem 2016; 192:1-8. [DOI: 10.1016/j.foodchem.2015.06.101] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Revised: 06/19/2015] [Accepted: 06/28/2015] [Indexed: 12/24/2022]
|
32
|
Davydova E, Wouters S, Deridder S, Desmet G, Eeltink S, Schoenmakers PJ. Design and evaluation of microfluidic devices for two-dimensional spatial separations. J Chromatogr A 2016; 1434:127-35. [PMID: 26810803 DOI: 10.1016/j.chroma.2016.01.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 12/22/2015] [Accepted: 01/04/2016] [Indexed: 10/22/2022]
Abstract
Various designs of chips for comprehensive two-dimensional spatial liquid chromatography were investigated. The performance of these chips was initially evaluated using computational fluid dynamics (CFD). A bifurcating distributor with an angle of 140° between branches was implemented in order to achieve a homogeneous velocity field. The cross-sectional area of the channels of the flow distributor was fixed at 0.5 × 0.5 mm, which allows a robust micromilling technique to be used for chip manufacturing. Experiments were performed with chips featuring purposely introduced imperfections in the structure of the bifurcating flow distributor to study its capacity of overcoming potential local clogging. Split peaks were observed when 75% of one of the flow channels was obstructed, in line with the CFD predictions. The main bottlenecks for the performance of the spatial two-dimensional chips were identified, viz. sample injected in the first dimension diverging into the flow distributor and channel discretization (i.e., remixing of first-dimension separation peaks because of finite number of second-dimension channels). Solutions to the former problem were studied by applying a flow resistance in the vertical segments that formed the outlets of the flow distributor and by simulating the presence of constrictions. It was found that a flow resistance of 1.0×10(11) m(-2) reduced the amount of sample diverging into the flow distributor by a factor of 10. The presence of a constriction of 90% of the segment area and 50% of the segment length decreased the diverging flow by a factor of 5. The influence of the linear velocity was significant. Solutions to the channel discretization problem were sought by investigating different designs of spatial two-dimensional chips.
Collapse
Affiliation(s)
- Ekaterina Davydova
- Analytical Chemistry Group, Van't Hoff Institute for Molecular Sciences, University of Amsterdam, P.O. Box 94157, 1090 GD Amsterdam, The Netherlands.
| | - Sam Wouters
- Vrije Universiteit Brussel, Department of Chemical Engineering, Brussels, Belgium
| | - Sander Deridder
- Vrije Universiteit Brussel, Department of Chemical Engineering, Brussels, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Department of Chemical Engineering, Brussels, Belgium
| | - Sebastiaan Eeltink
- Vrije Universiteit Brussel, Department of Chemical Engineering, Brussels, Belgium
| | - Peter J Schoenmakers
- Analytical Chemistry Group, Van't Hoff Institute for Molecular Sciences, University of Amsterdam, P.O. Box 94157, 1090 GD Amsterdam, The Netherlands
| |
Collapse
|
33
|
Urban J. Current trends in the development of porous polymer monoliths for the separation of small molecules. J Sep Sci 2015; 39:51-68. [DOI: 10.1002/jssc.201501011] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2015] [Revised: 09/17/2015] [Accepted: 09/18/2015] [Indexed: 01/15/2023]
Affiliation(s)
- Jiří Urban
- Department of Analytical Chemistry, Faculty of Chemical Technology; University of Pardubice; Pardubice Czech Republic
| |
Collapse
|
34
|
Computational investigation of longitudinal diffusion, eddy dispersion, and trans-particle mass transfer in bulk, random packings of core–shell particles with varied shell thickness and shell diffusion coefficient. J Chromatogr A 2015; 1407:139-56. [DOI: 10.1016/j.chroma.2015.06.047] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2015] [Revised: 06/09/2015] [Accepted: 06/14/2015] [Indexed: 11/22/2022]
|