1
|
Khodarahmian K, Ghiasvand A, Barkhordari A. Exploring the optimal electropolymerization strategy for the preparation of solid-phase microextraction fibers using pyrrole-dopamine copolymers. J Chromatogr A 2024; 1714:464562. [PMID: 38065025 DOI: 10.1016/j.chroma.2023.464562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 11/30/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024]
Abstract
In-situ electropolymerization of conductive polymers on the surface of stainless-steel substrates is a well-established but promising procedure for the preparation of solid-phase microextraction (SPME) tools. Herein, different electrochemical methods including constant potential (CP), constant potential pulse (CPP), and cyclic voltammetry (CV) were utilized to fabricate SPME fibers by in-situ electropolymerization of pyrrole-dopamine copolymers (PPY/PDA) on the surface of stainless-steel fibers. The coated fibers were characterized and applied for the direct-immersion SPME (DI-SPME) sampling of ultra-trace amounts of plant hormones including abscisic acid (ABA), gibberellic acid (GA3), and indole acetic acid (IAA) in fruit juices, followed by HPLC-UV determination. The results showed that CV electropolymerization is significantly more efficient than the two other methods. The coatings created by the CV method were satisfactorily uniform, adhesive, and durable and exhibited higher extraction performance compared to the CP and CPP procedures. The important experimental variables of the proposed DI-SPME-HPLC method were evaluated and optimized using response surface methodology with a Box-Behnken design. The developed method showed wide-range linearities, spanning from 0.05 to 20μg mL-1 for GA3, and 0.02 to 20μg mL-1 for ABA and IAA. The limits of detection were obtained 0.01μg mL-1 for GA3, and 0.005μg mL-1 for ABA and IAA. The fiber was successfully employed for the simultaneous DI-SPME-HPLC analysis of plant hormones in fruit juice samples.
Collapse
Affiliation(s)
- Kobra Khodarahmian
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Alireza Ghiasvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran.
| | - Abdullah Barkhordari
- Environmental and Occupational Health Research Center, Shahroud University of Medical Sciences, Shahroud, Iran
| |
Collapse
|
2
|
Koonani S, Ghiasvand A. A comprehensive theory for vacuum-assisted headspace extraction of solid samples. J Chromatogr A 2023; 1712:464465. [PMID: 37907003 DOI: 10.1016/j.chroma.2023.464465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 09/25/2023] [Accepted: 10/17/2023] [Indexed: 11/02/2023]
Abstract
Vacuum-assisted headspace extraction (VA-HSE) has proven to be an efficient solution for the rapid and effective extraction of volatile and semi-volatile species. The research has been mainly focused on liquid samples by considering differences in Henry's constants, while the accelerating effect of vacuum is more significant and practically more important in solid samples with complex matrices. Nevertheless, the lack of a comprehensive theory for VA-HSE in solid samples, based on the adsorption/desorption phenomena, is quite evident. This research was done with the aim of modeling VA-HSE of solid samples from a thermodynamic point of view. To understand the impact and mechanism of reduced pressure, the sampling space was divided into three separate areas including the solid matrix (the surface and cavities of the solid sample), the headspace of the sample, and the extraction phase (the surface and cavities of the adsorbent). The effects of vacuum on the movement of analyte molecules in all three areas were investigated and included in a comprehensive equation. According to the theoretical model, when a solid sample is subjected to vacuum conditions, the enthalpy of the analytes in their free state decreases. As a result, the analytes become more volatile. Additionally, vacuum reduces the thickness of the boundary layer in solid samples. This facilitates the diffusion of analyte molecules into the cavities within the solid material and eventually into the headspace of the sample. A similar effect is observed on the extractive phase side when vacuum is applied. The reduction in boundary layer thickness promotes the adsorption of analytes onto the extractive phase, thereby facilitating a quicker equilibrium of analyte concentration in the extraction phase. The proposed model was validated by correlating it with the experimental data found in the literature. The results of this analysis have shown a robust correlation between the theoretical model and the experimental data, bolstering the reliability of the model, and highlighting its practical relevance.
Collapse
Affiliation(s)
- Samira Koonani
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Alireza Ghiasvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran.
| |
Collapse
|
3
|
Maleki S, Hashemi P, Adeli M. A simple and portable vacuum assisted headspace solid phase microextraction device coupled to gas chromatography based on covalent organic framework/metal organic framework hybrid for simultaneous analysis of volatile and semi-volatile compounds in soil. J Chromatogr A 2023; 1705:464195. [PMID: 37423076 DOI: 10.1016/j.chroma.2023.464195] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 07/02/2023] [Accepted: 07/03/2023] [Indexed: 07/11/2023]
Abstract
Various microextraction methods have demonstrated a positive effect when assisted by vacuum. However, working with such systems is often laborious, they often require expensive and non-portable vacuum pumps, and may even suck off some sample vapor or solid particles during the evacuation process. To address these issues, a simple, and affordable vacuum-assisted headspace solid-phase microextraction (HS-SPME) device was developed in this study. The device, named In Syringe Vacuum-assisted HS-SPME (ISV-HS-SPME), utilizes an adjustable 40 mL glass syringe as a vacuum provider and sampling vessel. A new fiber coating, made from a hybrid of covalent triazine-based frameworks and metal-organic frameworks (COF/MOF), was prepared and characterized by Fourier transform infrared spectrometry, field emission scanning electron microscopy, energy dispersive X-ray, X-ray diffraction, thermogravimetric analysis, and Brunauer-Emmett-Teller techniques for use in the ISV-HS-SPME. By optimizing parameters such as extraction temperature, extraction time, desorption temperature, desorption time, and, humidity using a simplex method, the ISV system was found to increase the extraction efficiency of polycyclic aromatic hydrocarbons (PAHs) and benzene, toluene, ethylbenzene, and xylenes (BTEX) in solid samples by up to 175%. The determinations were followed by GC-FID measurements. Compared to three commercially available fibers, the ISV-HS-SPME device with the COF/MOF (2DTP/MIL-101-Cr) fiber exhibited significantly higher peak areas for PAHs and BTEX. The linear dynamic ranges for BTEX and PAHs were 7.1-9000 ng g-1 and 0.23-9000 ng g-1, respectively, with limits of detection ranging from 2.1-5 ng g-1 for BTEX and 0.07-1.6 ng g-1 for PAHs. The relative standard deviation of the method was 2.6-7.8% for BTEX and 1.6-6.7% for PAHs. The ISV-HS-SPME was successfully used to simultaneously determine PAHs and BTEX in polluted soil samples with recoveries ranging from 80.4 to 108%.
Collapse
Affiliation(s)
- Sara Maleki
- Department of analytical chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Payman Hashemi
- Department of analytical chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran.
| | - Mohsen Adeli
- Department of analytical chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| |
Collapse
|
4
|
Xu L, Hu W, Luo X, Zhang J. Covalent organic framework in situ grown on the metal-organic framework as fiber coating for solid-phase microextraction of polycyclic aromatic hydrocarbons in tea. Mikrochim Acta 2023; 190:344. [PMID: 37542665 DOI: 10.1007/s00604-023-05915-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 07/13/2023] [Indexed: 08/07/2023]
Abstract
A novel MIL-88-NH2@COF composite was produced by in situ growth of covalent organic framework (COF) on the metal-organic framework (MOF) surface. To obtain a coating fiber for solid-phase microextraction (SPME), the MIL-88-NH2@COF composite physically adhered to the stainless steel wire. Combined with gas chromatography-flame ionization detection (GC-FID), various analytes such as chlorophenols (CPs), phthalates (PAEs), and polycyclic aromatic hydrocarbons (PAHs) were extracted and determined to evaluate the extraction performance of MIL-88-NH2@COF coated fibers and explore their extraction mechanism. This composite exhibit excellent extraction performance and adsorption capacity for various analytes, especially for PAHs with enrichment factor up to 9858. The SPME-GC-FID method based on MIL-88-NH2@COF fiber was established for the determination of five PAHs after the main extraction conditions were optimized. Under optimal conditions, the proposed technique showed a wide linear range (1-150 ng mL-1) with a low limit of detection (0.019 ng mL-1) and a high coefficient of determination (R2 > 0.99). The developed SPME-GC-FID method was used to determine PAHs in green tea and black tea samples, with good recoveries of 51.70-103.64% and 68.56-103.64%, respectively. It is worth mentioning that this is the first time MIL-88-NH2@COF composites have been prepared and applied to SPME. The preparation method of the composite provides a new idea in adsorbent preparation, which will contribute to the field of SPME.
Collapse
Affiliation(s)
- Li Xu
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, People's Republic of China
| | - Wei Hu
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, People's Republic of China
| | - Xiaogang Luo
- School of Chemical Engineering and Pharmacy, Key Laboratory for Green Chemical Process of Ministry of Education, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Juan Zhang
- School of Chemistry and Environmental Engineering, Hubei Key Laboratory of Novel Reactor and Green Chemical Technology, Wuhan Institute of Technology, Wuhan, 430205, People's Republic of China.
| |
Collapse
|
5
|
Peng S, Huang X, Huang Y, Huang Y, Zheng J, Zhu F, Xu J, Ouyang G. Novel solid-phase microextraction fiber coatings: A review. J Sep Sci 2021; 45:282-304. [PMID: 34799963 DOI: 10.1002/jssc.202100634] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 11/13/2021] [Accepted: 11/15/2021] [Indexed: 12/27/2022]
Abstract
The materials used for the fabrication of solid-phase microextraction fiber coatings in the past five years are summarized in the current review, including carbon, metal-organic frameworks, covalent organic frameworks, aerogel, polymer, ionic liquids/poly (ionic liquids), metal oxides, and natural materials. The preparation approaches of different coatings, such as sol-gel technique, in-situ growth, electrodeposition, and glue methods, are briefly reviewed together with the evolution of the supporting substrates. In addition, the limitations of the current coatings and the future development directions of solid-phase microextraction are presented.
Collapse
Affiliation(s)
- Sheng Peng
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Xiaoyu Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Yuyan Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Yiquan Huang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Juan Zheng
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Fang Zhu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Jianqiao Xu
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Gangfeng Ouyang
- MOE Key Laboratory of Bioinorganic and Synthetic Chemistry, KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| |
Collapse
|
6
|
Derikvand A, Ghiasvand A, Dalvand K, Haddad PR. Fabrication and evaluation of a portable low-pressure headspace solid-phase microextraction device for on-site analysis. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
7
|
Nanostructured octadecylsilica chemically coated stainless-steel fiber for vacuum-assisted HS-SPME sampling of PAHs in soil. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105201] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
8
|
Beiranvand M, Ghiasvand A. An ultrasound-assisted pressure-regulated solid-phase microextraction setup for fast and sensitive analysis of volatile pollutants in contaminated soil. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:36306-36315. [PMID: 32556985 DOI: 10.1007/s11356-020-09620-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 06/04/2020] [Indexed: 06/11/2023]
Abstract
Release of analytes from their native matrix and diffusion into the gas phase is the rate-limiting step for the sampling of volatiles in complex solid samples. This limitation is more serious in the solvent-less and solvent-free microextraction sampling strategies. In this research, a three-stage reinforced sampling strategy including high-pressure/sonication/low-pressure was introduced for fast and efficient release of analytes in soil samples. For this purpose, a novel ultrasound-assisted pressure-regulated solid-phase microextraction (UA-PR-SPME) device was developed. It was coupled with gas chromatography-flame ionization detection (GC-FID) and carried out for the determination of benzene, toluene, ethylbenzene, and xylenes (BTEX, as the model analytes) in complex solid samples. Graphene oxide/3-aminopropyltriethoxysilane (GO-APTES) nanocomposite was synthesized and used as the SPME fiber coating. Under optimal conditions, the limits of detection (LODs) were obtained 0.1-0.4 ng/g. The calibration curves were linear over the range of 2.4-5000 ng/g. Relative standard deviations (RSDs%) were calculated 5.1-7.0% (n = 6). The developed technique was employed for the analysis of BTEX in contaminated soil samples.
Collapse
Affiliation(s)
| | - Alireza Ghiasvand
- Department of Chemistry, Lorestan University, Khoramabad, Iran.
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia.
| |
Collapse
|
9
|
Jalili V, Barkhordari A, Ghiasvand A. Solid-phase microextraction technique for sampling and preconcentration of polycyclic aromatic hydrocarbons: A review. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104967] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
10
|
Ghaedrahmati L, Ghiasvand A, Heidari N. Headspace solid-phase microextraction sampling of endogenous aldehydes in biological fluids using a magnetic metal-organic framework/polyaniline nanocomposite. J Sep Sci 2020; 44:1130-1139. [PMID: 32627944 DOI: 10.1002/jssc.202000401] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 07/01/2020] [Accepted: 07/02/2020] [Indexed: 01/13/2023]
Abstract
Nanoporosity, crystal structure, good thermal and mechanical stability, high surface-to-volume ratio, nanoscale cavities, and uniform pore topology have made metal-organic frameworks one of the best class of sorbents for adsorption/separation purposes. In this research, a metal-organic framework/polyaniline magnetite nanocomposite was synthesized and intercalated by polyaniline by electrophoretic deposition on the surface of a thin steel wire, to prepare a solid-phase microextraction fiber. It was coupled with gas chromatography-flame ionization detection and employed for the extraction and determination of aldehydes in biological samples. The magnetic nanocomposite was characterized using scanning electron microscopy, energy dispersive X-ray analysis, and Fourier transform infrared spectroscopy. Under the optimal experimental conditions, the calibration curves were linear in the range of 0.01-1 and 0.1-1 µg/L for hexanal and heptanal, respectively. The limits of detections for hexanal and heptanal were 0.001 and 0.01 µg/L, respectively. Intrafiber repeatability for six replicate analyses of 0.2 µg/L of the analytes was over the range 3.5-7.1%. Interfiber (fiber-to-fiber) reproducibility, calculated by six replicate analyses of the same concentration using three different fibers, and was found to be 10.4-15.7%. The developed procedure was successfully utilized for the analysis of hexanal and heptanal in human plasma and urine samples.
Collapse
Affiliation(s)
| | - Alireza Ghiasvand
- Department of Chemistry, Lorestan University, Khoramabad, Iran.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Australia
| | - Nahid Heidari
- Department of Chemistry, Lorestan University, Khoramabad, Iran
| |
Collapse
|
11
|
Ilipronti T, de Campos SD, Cabral Muller C, de Campos ÉA. SPME fiber coated by arrayed ZNRs for sampling and concentration of polar residual solvents for further analysis using GC FID. J Pharm Biomed Anal 2019; 174:644-649. [PMID: 31279894 DOI: 10.1016/j.jpba.2019.06.037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 06/25/2019] [Accepted: 06/26/2019] [Indexed: 12/12/2022]
Abstract
In this work, fused silica coated by arrayed ZNRs were successfully applied as a sorbent for analysis of polar residual solvents in pantoprazole feedstocks. ZnO nanoparticles were produced and deposited on a fused silica surface applying the dip coating technique and hydrothermal growth to synthesize the arrayed nanorods. The ZNRs array fiber coating was characterized by SEM, EDS, XRD, and TGA. The manufactured SPME fiber was coupled to a glass syringe of 10 μL and applied for the sampling of acetone, n-butanol, dichloromethane, ethyl acetate and methanol for further analysis using GC FID. Optimum operating conditions were determined for the incubation temperature (70 °C), incubation time (15 min), extraction time (120 s), and desorption time (0.6 min). Employing the optimum conditions, the proposed method resulted in a good linearity (> 0.997) and precision (< 7.1%) for the evaluated analytes. Recovery tests were also performed on three levels (below, equal to and above the ICH specification limit for residual solvents in pharmaceutical products). Recoveries ranging from 96% to 107% were obtained. Comparison between the reference method and developed method shows errors smaller than 4%.
Collapse
Affiliation(s)
- Thiago Ilipronti
- Centro de Engenharias e Ciências Exatas, Universidade Estadual do Oeste do Paraná -Unioeste, Toledo, Paraná, 85903-000, Brazil
| | - Sílvia Denofre de Campos
- Centro de Engenharias e Ciências Exatas, Universidade Estadual do Oeste do Paraná -Unioeste, Toledo, Paraná, 85903-000, Brazil
| | - Cristiano Cabral Muller
- Centro de Engenharias e Ciências Exatas, Universidade Estadual do Oeste do Paraná -Unioeste, Toledo, Paraná, 85903-000, Brazil
| | - Élvio Antônio de Campos
- Centro de Engenharias e Ciências Exatas, Universidade Estadual do Oeste do Paraná -Unioeste, Toledo, Paraná, 85903-000, Brazil.
| |
Collapse
|
12
|
Rasolzadeh F, Hashemi P. Magnetic fiber headspace solid-phase microextraction coupled to GC-MS for the extraction and quantitation of polycyclic aromatic hydrocarbons. Mikrochim Acta 2019; 186:432. [PMID: 31197476 DOI: 10.1007/s00604-019-3482-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Accepted: 05/05/2019] [Indexed: 02/06/2023]
Abstract
A technique was developed for magnetic fiber headspace-solid phase microextraction (MF-HS-SPME) of polycyclic aromatic hydrocarbons (PAHs). The efficiency of the extraction of a steel SPME fiber coated with an aminoethyl-functionalized SBA-15 (Santa Barbara Amorphous 15; a nanoporous sorbent) is substantially improved after its magnetization during HS-SPME. The effects of magnetic field strength, extraction temperature, extraction time, moisture content of the sample, desorption time and desorption temperature were optimized using a simplex method. The application of a moderately strong magnetic field to the fiber results in up to 135% increase in the extraction efficiency and wider linear dynamic ranges. The PAHs (specifically naphthalene, acenaphthene, fluorene, anthracene, phenanthrene, fluoranthene and pyrene) were then quantified by GC-MS analysis. Comparison of an electromagnet and a permanent magnet indicated the superior effect of the permanent magnet for the target analytes due to the Ohmic heating of the magnetic coil and its negative effect on the extraction of some of the PAHs. The limits of detections of the PAHs are between 0.17 to 0.57 ng g-1 by using the electromagnet, and between 0.10 and 0.32 ng g-1 for the permanent magnet. Relative standard deviations of 2.9 to 7.6% were obtained for six replicated analyses of the analytes. The method was applied to some polluted soil samples, and satisfactory results were obtained. Graphical abstract Schematic representation of the designed magnetic fiber headspace solid-phase microextraction (MF-HS-SPME) system using (a) an electromagnet, (b) a pair of permanent disc magnets.
Collapse
Affiliation(s)
- Fahimeh Rasolzadeh
- Department of Chemistry, Faculty of Science, Lorestan University, Khoramabad, 6815144316, Iran
| | - Payman Hashemi
- Department of Chemistry, Faculty of Science, Lorestan University, Khoramabad, 6815144316, Iran.
| |
Collapse
|
13
|
Iron oxide/silica/polypyrrole nanocomposite sorbent for the comparison study of direct-immersion and headspace solid-phase microextraction of aldehyde biomarkers in human urine. J Pharm Biomed Anal 2018; 159:37-44. [DOI: 10.1016/j.jpba.2018.06.052] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 05/25/2018] [Accepted: 06/25/2018] [Indexed: 11/17/2022]
|
14
|
Comparison of the Conventional and Electroenhanced Direct-Immersion Solid-Phase Microextraction for Sampling of Nicotine in Biological Fluids of the Human Body. Molecules 2018; 23:molecules23051171. [PMID: 29757971 PMCID: PMC6099498 DOI: 10.3390/molecules23051171] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 04/30/2018] [Accepted: 05/09/2018] [Indexed: 12/19/2022] Open
Abstract
A stainless steel fiber was made porous and adhesive by platinization and then coated by nanostructured polypyrrole (PPy), using an appropriate electrophoretic deposition (EPD) method. The morphological surface structure and functional groups of the PPy-coated fiber were studied using SEM (Scanning electron microscope) instrument. The prepared fiber was used for comparison of direct immersion (DI) and electroenhanced direct immersion solid-phase microextraction (EE-DI-SPME) of nicotine in human plasma and urine samples followed by gas chromatography flame ionization detector (GC-FID) determination. The effects of the influential experimental parameters on the efficiency of the DI-SPME and EE-DI-SPME methods, including the pH and ionic strength of the sample solution, applied Direct current (DC) voltage, extraction temperature and time and stirring rate, were optimized. Under the optimal conditions, the calibration curves for the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were linear over the ranges of 0.1⁻10.0 μg mL-1 and 0.001⁻10.0 μg mL-1, respectively. The relative standard deviations (RSDs, n = 6) were found to be 6.1% and 4.6% for the DI and EE strategies, respectively. The LODs (limit of detection) of the DI-SPME-GC-FID and EE-DI-SPME-GC-FID methods were found to be 10 and 0.3 ng mL-1, respectively. The relative recovery values (for the analysis of 1 µg mL-1 nicotine) were found to be 91⁻110% for EE-DI-SPME and 75⁻105% for DI-SPME. The enrichment factors for DI-SPME and EE-DI-SPME sampling were obtained as 38,734 and 50,597, respectively. The results indicated that EE-SPME was more efficient for quantitation of nicotine in biological fluids. The developed procedure was successfully carried out for the extraction and measurement of nicotine in real plasma and urine samples.
Collapse
|