1
|
Solanki R, Patra I, Kumar TCA, Kumar NB, Kandeel M, Sivaraman R, Turki Jalil A, Yasin G, Sharma S, Abdulameer Marhoon H. Smartphone-Based Techniques Using Carbon Dot Nanomaterials for Food Safety Analysis. Crit Rev Anal Chem 2024; 54:923-941. [PMID: 35857650 DOI: 10.1080/10408347.2022.2099733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
The development of portable and efficient nanoprobes to realize the quantitative/qualitative onsite determination of food pollutants is of immense importance for safeguarding human health and food safety. With the advent of the smartphone, the digital imaging property causes it to be an ideal diagnostic substrate to point-of-care analysis probes. Besides, merging the versatility of carbon dots nanostructures and bioreceptor abilities has opened an innovative assortment of construction blocks to design advanced nanoprobes or improving those existing ones. On this ground, massive endeavors have been made to combine mobile phones with smart nanomaterials to produce portable (bio)sensors in a reliable, low cost, rapid, and even facile-to-implement area with inadequate resources. Herein, this work outlines the latest advancement of carbon dots nanostructures on smartphone for onsite detecting of agri-food pollutants. Particularly, we afford a summary of numerous approaches applied for target molecule diagnosis (pesticides, mycotoxins, pathogens, antibiotics, and metal ions), for instance microscopic imaging, fluorescence, colorimetric, and electrochemical techniques. Authors tried to list those scaffolds that are well-recognized in complex media or those using novel constructions/techniques. Lastly, we also point out some challenges and appealing prospects related to the enhancement of high-efficiency smartphone based carbon dots systems.
Collapse
Affiliation(s)
- Reena Solanki
- Department of Chemistry, Dr APJ Abdul Kalam University, Indore, India
| | | | - T Ch Anil Kumar
- Department of Mechanical Engineering, Vignan's Foundation for Science Technology and Research, Vadlamudi, India
| | - N Bharath Kumar
- Department of Electrical and Electronics Engineering, Vignan's Foundation for Science Technology and Research, Guntur, India
| | - Mahmoud Kandeel
- Department of Biomedical Sciences, College of Veterinary Medicine, King Faisal University, Al-Ahsa, Saudi Arabia
| | - R Sivaraman
- Department of Mathematics, Dwaraka Doss Goverdhan Doss Vaishnav College, University of Madras, Arumbakkam, Chennai, India
| | - Abduladheem Turki Jalil
- Medical Laboratories Techniques Department, Al-Mustaqbal University College, Babylon, Hilla, Iraq
| | - Ghulam Yasin
- Department of Botany, university of Bahauddin Zakariya, Multan, Pakistan
| | - Sandhir Sharma
- Chitkara Business School, Chitkara University, Punjab, India
| | - Haydar Abdulameer Marhoon
- Information and Communication Technology Research Group, Scientific Research Center, Al-Ayen University, Iraq
| |
Collapse
|
2
|
Towards the development of paper analytical devices for testing alkaline phosphatase, starch, and urea in milk. Int Dairy J 2022. [DOI: 10.1016/j.idairyj.2022.105470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
3
|
Alonzo LF, Hinkley TC, Miller A, Calderon R, Garing S, Williford J, Clute-Reinig N, Spencer E, Friend M, Madan D, Dinh VTT, Bell D, Weigl BH, Nugen SR, Nichols KP, Le Ny ALM. A microfluidic device and instrument prototypes for the detection of Escherichia coli in water samples using a phage-based bioluminescence assay. LAB ON A CHIP 2022; 22:2155-2164. [PMID: 35521688 DOI: 10.1039/d1lc00888a] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Current quantification methods of Escherichia coli (E. coli) contamination in water samples involve long incubation, laboratory equipment and facilities, or complex processes that require specialized training for accurate operation and interpretation. To address these limitations, we have developed a microfluidic device and portable instrument prototypes capable of performing a rapid and highly sensitive bacteriophage-based assay to detect E. coli cells with detection limit comparable to traditional methods in a fraction of the time. The microfluidic device combines membrane filtration and selective enrichment using T7-NanoLuc-CBM, a genetically engineered bacteriophage, to identify 4.1 E. coli CFU in 100 mL of drinking water within 5.5 hours. The microfluidic device was designed and tested to process up to 100 mL of real-world drinking water samples with turbidities below 10 NTU. Prototypes of custom instrumentation, compatible with our valveless microfluidic device and capable of performing all of the assay's units of operation with minimal user intervention, demonstrated similar assay performance to that obtained on the benchtop assay. This research is the first step towards a faster, portable, and semi-automated, phage-based microfluidic platform for improved in-field water quality monitoring in low-resource settings.
Collapse
Affiliation(s)
- Luis F Alonzo
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Troy C Hinkley
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Andrew Miller
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Ryan Calderon
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Spencer Garing
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - John Williford
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Nick Clute-Reinig
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Ethan Spencer
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Michael Friend
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Damian Madan
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Van T T Dinh
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - David Bell
- Independent Consultant, Issaquah, WA 98027, USA
| | - Bernhard H Weigl
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Sam R Nugen
- Department of Food Science, Cornell University, Ithaca, NY 14850, USA
| | - Kevin P Nichols
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| | - Anne-Laure M Le Ny
- Intellectual Ventures Laboratory, 14360 SE Eastgate Way, Bellevue, WA 98007, USA
| |
Collapse
|
4
|
Sivakumar R, Lee NY. Recent progress in smartphone-based techniques for food safety and the detection of heavy metal ions in environmental water. CHEMOSPHERE 2021; 275:130096. [PMID: 33677270 DOI: 10.1016/j.chemosphere.2021.130096] [Citation(s) in RCA: 57] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 02/10/2021] [Accepted: 02/21/2021] [Indexed: 05/14/2023]
Abstract
Emerging smartphone-based point-of-care tests (POCTs) are cost-effective, precise, and easy to implement in resource-limited areas. Thus, they are considered a potential alternative to conventional diagnostic testing. This review explores food safety and the detection of metal ions in environmental water based on unprecedented smartphone technology. Specifically, we provide an overview of various methods used for target analyte detection (antibiotics, enzymes, mycotoxins, pathogens, pesticides, small molecules, and metal ions), such as colorimetric, fluorescence, microscopic imaging, and electrochemical methods. This paper performs a comprehensive review of smartphone-based POCTs developed in the last three years (2018-2020) and evaluates their relative advantages and limitations. Moreover, we discuss the imperative role of new technology in the progress of POCTs. Sensor materials (metal nanoparticles, carbon dots, quantum dots, organic substrates, etc.) and detection techniques (paper-based, later flow assay, microfluidic platform, etc.) involved in POCTs based on smartphones, and the challenges faced by these techniques, are addressed.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of Industrial Environmental Engineering, College of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
5
|
Calabretta M, Montali L, Lopreside A, Fragapane F, Iacoangeli F, Roda A, Bocci V, D’Elia M, Michelini E. Ultrasensitive On-Field Luminescence Detection Using a Low-Cost Silicon Photomultiplier Device. Anal Chem 2021; 93:7388-7393. [PMID: 33973781 PMCID: PMC8253476 DOI: 10.1021/acs.analchem.1c00899] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 04/27/2021] [Indexed: 12/14/2022]
Abstract
The availability of portable analytical devices for on-site monitoring and rapid detection of analytes of forensic, environmental, and clinical interest is vital. We report the development of a portable device for the detection of biochemiluminescence relying on silicon photomultiplier (SiPM) technology, called LuminoSiPM, which includes a 3D printed sample holder that can be adapted for both liquid samples and paper-based biosensing. We performed a comparison of analytical performance in terms of detectability with a benchtop luminometer, a portable cooled charge-coupled device (CCD sensor), and smartphone-integrated complementary metal oxide semiconductor (CMOS) sensors. As model systems, we used two luciferase/luciferin systems emitting at different wavelengths using purified protein solutions: the green-emitting P. pyralis mutant Ppy-GR-TS (λmax 550 nm) and the blue-emitting NanoLuc (λmax 460 nm). A limit of detection of 9 femtomoles was obtained for NanoLuc luciferase, about 2 and 3 orders of magnitude lower than that obtained with the portable CCD camera and with the smartphone, respectively. A proof-of-principle forensic application of LuminoSiPM is provided, exploiting an origami chemiluminescent paper-based sensor for acetylcholinesterase inhibitors, showing high potential for this portable low-cost device for on-site applications with adequate sensitivity for detecting low light intensities in critical fields.
Collapse
Affiliation(s)
- Maria
Maddalena Calabretta
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
| | - Laura Montali
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
| | - Antonia Lopreside
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
| | - Fabio Fragapane
- Gabinetto
Regionale di Polizia Scientifica per l’Emilia-Romagna, 40123, Bologna, Italy
| | | | - Aldo Roda
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- INBB, Istituto
Nazionale di Biostrutture e Biosistemi, 00136 Rome, Italy
| | - Valerio Bocci
- INFN,
Istituto Nazionale di Fisica Nucleare Sezione di Roma, 00185 Rome, Italy
| | - Marcello D’Elia
- Gabinetto
Regionale di Polizia Scientifica per l’Emilia-Romagna, 40123, Bologna, Italy
| | - Elisa Michelini
- Department
of Chemistry “Giacomo Ciamician”, University of Bologna, 40126 Bologna, Italy
- Center
for Applied Biomedical Research (CRBA), University of Bologna, 40126 Bologna, Italy
- INBB, Istituto
Nazionale di Biostrutture e Biosistemi, 00136 Rome, Italy
- Health
Sciences and Technologies-Interdepartmental Center for Industrial
Research (HST-ICIR), University of Bologna, 40126 Bologna, Italy
| |
Collapse
|