1
|
Yang DH, Lee NY. Electrospun fibers modified with polydopamine for enhancing human mesenchymal stem cell culture. Biomed Mater 2024. [PMID: 38729192 DOI: 10.1088/1748-605x/ad49f7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/12/2024]
Abstract
In this study, we coated electrospun polycaprolactone (PCL) fibers with polydopamine (PDA) to modify their hydrophobicity and fabricated a matrix for culturing mesenchymal stem cells (MSCs). Additionally, we incorporated Arg-Gly-Asp (RGD) peptides into PDA to enhance MSCs culture performance on PCL fibers. PDA and RGD were successfully coated in one step by immersing the electrospun fibers in a coating solution, without requiring an additional surface activation process. The characteristics of functionalized PCL fibers were analyzed by scanning electron microscope (SEM) with energy-dispersive X-ray (EDX) analysis, Fourier transform infrared (FTIR) spectroscopy, water contact angle measurement, and fluorescence measurements using a carboxylic-modified fluorescent microsphere. MSCs cultured on the modified PCL fibers demonstrated enhanced cell adhesion, proliferation, and osteogenic- and chondrogenic differentiation. This study provides insight into potential applications for scaffold fabrication in MSCs-based tissue engineering, wound dressing, implantation, and a deeper understanding of MSCs behavior in vitro.
.
Collapse
Affiliation(s)
- Da Hyun Yang
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam, 13120, Korea (the Republic of)
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam, Gyeonggi-do, 13120, Korea (the Republic of)
| |
Collapse
|
2
|
Park SY, Trinh KTL, Song YJ, Lee NY. Pipette-free field-deployable molecular diagnostic kit for bimodal visual detection of infectious RNA viruses. Biotechnol J 2024; 19:e2300521. [PMID: 38403439 DOI: 10.1002/biot.202300521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/22/2023] [Accepted: 01/08/2024] [Indexed: 02/27/2024]
Abstract
Here, we developed a field-deployable molecular diagnostic kit for the detection of RNA viruses that operates in a pipette-free manner. The kit is composed of acrylic sticks, PCR tubes, and palm-sized three-dimensional(3D)-printed heaters operated by batteries. The kit performs RNA extraction, reverse transcriptase loop-mediated isothermal amplification (RT-LAMP), and visual detection in one kit. An acrylic stick was engraved with one shallow and one deep cylindrical chamber at each end for the insertion of an FTA card and ethidium homodimer-1 (EthD-1), respectively, to perform RNA extraction/purification and bimodal visual detection of the target amplicons. First, an intercalation of EthD-1 into the target DNA initially produces fluorescence upon UV illumination. Next, the addition of a strong oxidant, in this case sodium (meta) periodate (NaIO4 ), produces intense aggregates in the presence of EthD-1-intercalated DNA, realized by electrostatic interaction. In the absence of the target amplicon, no fluorescence or aggregates are observed. Using this kit, two major infectious viruses-severe fever with thrombocytopenia syndrome virus (SFTSV) and severe acute respiratory syndrome coronavirus (SARS-CoV-2)-were successfully detected in 1 h, and the limits of detection (LOD) were approximately 1 virus μL-1 for SFTSV and 103 copies μL-1 for SARS-CoV-2 RNA. The introduced kit is portable, end-user-friendly, and can be operated in a pipette-free manner, paving the way for simple and convenient virus detection in resource-limited settings.
Collapse
Affiliation(s)
- So Yeon Park
- Department of BioNano Technology, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Yoon-Jae Song
- Department of Life Science, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea
| |
Collapse
|
3
|
Gouw ZAR, Jeong J, Rimner A, Lee NY, Jackson A, Fu A, Sonke JJ, Deasy JO. "Primer shot" fractionation with an early treatment break is theoretically superior to consecutive weekday fractionation schemes for early-stage non-small cell lung cancer. Radiother Oncol 2024; 190:110006. [PMID: 37972733 DOI: 10.1016/j.radonc.2023.110006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 10/14/2023] [Accepted: 11/02/2023] [Indexed: 11/19/2023]
Abstract
PURPOSE Radiotherapy is traditionally given in equally spaced weekday fractions. We hypothesize that heterogeneous interfraction intervals can increase radiosensitivity via reoxygenation. Through modeling, we investigate whether this minimizes local failures and toxicity for early-stage non-small cell lung cancer (NSCLC). METHODS Previously, a tumor dose-response model based on resource competition and cell-cycle-dependent radiosensitivity accurately predicted local failure rates for early-stage NSCLC cohorts. Here, the model mathematically determined non-uniform inter-fraction intervals minimizing local failures at similar normal tissue toxicity risk, i.e., iso-BED3 (iso-NTCP) for fractionation schemes 18Gyx3, 12Gyx4, 10Gyx5, 7.5Gyx8, 5Gyx12, 4Gyx15. Next, we used these optimized schedules to reduce toxicity risk (BED3) while maintaining stable local failures (TCP). RESULTS Optimal schedules consistently favored a "primer shot" fraction followed by a 2-week break, allowing tumor reoxygenation. Increasing or decreasing the assumed baseline hypoxia extended or shortened this optimal break by up to one week. Fraction sizes of 7.5 Gy and up required a single primer shot, while smaller fractions needed one or two extra fractions for full reoxygenation. The optimized schedules, versus consecutive weekday fractionation, predicted absolute LF reductions of 4.6%-7.4%, except for the already optimal LF rate seen for 18Gyx3. Primer shot schedules could also reduce BED3 at iso-TCP with the biggest improvements for the shortest schedules (94.6Gy reduction for 18Gyx3). CONCLUSION A validated simulation model clearly supports non-standard "primer shot" fractionation, reducing the impact of hypoxia-induced radioresistance. A limitation of this study is that primer-shot fractionation is outside prior clinical experience and therefore will require clinical studies for definitive testing.
Collapse
Affiliation(s)
- Z A R Gouw
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, NY, USA; The Netherlands Cancer Institute, Amsterdam, Department of Radiation Oncology, the Netherlands.
| | - J Jeong
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, NY, USA
| | - A Rimner
- Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, New York, NY, USA
| | - N Y Lee
- Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, New York, NY, USA
| | - A Jackson
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, NY, USA
| | - A Fu
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, NY, USA
| | - J-J Sonke
- The Netherlands Cancer Institute, Amsterdam, Department of Radiation Oncology, the Netherlands
| | - J O Deasy
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, NY, USA
| |
Collapse
|
4
|
Diep Trinh TN, Trinh KTL, Lee NY. Microfluidic advances in food safety control. Food Res Int 2024; 176:113799. [PMID: 38163712 DOI: 10.1016/j.foodres.2023.113799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/23/2023] [Accepted: 12/02/2023] [Indexed: 01/03/2024]
Abstract
Food contamination is a global concern, particularly in developing countries. Two main types of food contaminants-chemical and biological-are common problems that threaten human health. Therefore, rapid and accurate detection methods are required to address the threat of food contamination. Conventional methods employed to detect these two types of food contaminants have several limitations, including high costs and long analysis time. Alternatively, microfluidic technology, which allows for simple, rapid, and on-site testing, can enable us to control food safety in a timely, cost-effective, simple, and accurate manner. This review summarizes advances in microfluidic approaches to detect contaminants in food. Different detection methods have been applied to microfluidic platforms to identify two main types of contaminants: chemical and biological. For chemical contaminant control, the application of microfluidic approaches for detecting heavy metals, pesticides, antibiotic residues, and other contaminants in food samples is reviewed. Different methods including enzymatic, chemical-based, immunoassay-based, molecular-based, and electrochemical methods for chemical contaminant detection are discussed based on their working principle, the integration in microfluidic platforms, advantages, and limitations. Microfluidic approaches for foodborne pathogen detection, from sample preparation to final detection, are reviewed to identify foodborne pathogens. Common methods for foodborne pathogens screening, namely immunoassay, nucleic acid amplification methods, and other methods are listed and discussed; highlighted examples of recent studies are also reviewed. Challenges and future trends that could be employed in microfluidic design and fabrication process to address the existing limitations for food safety control are also covered. Microfluidic technology is a promising tool for food safety control with high efficiency and applicability. Miniaturization, portability, low cost, and samples and reagents saving make microfluidic devices an ideal choice for on-site detection, especially in low-resource areas. Despite many advantages of microfluidic technology, the wide manufacturing of microfluidic devices still demands intensive studies to be conducted for user-friendly and accurate food safety control. Introduction of recent advances of microfluidic devices will build a comprehensive understanding of the technology and offer comparative analysis for future studies and on-site application.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Materials Science, School of Applied Chemistry, Tra Vinh University, Viet Nam
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea.
| |
Collapse
|
5
|
Thai DA, Park SK, Lee NY. A paper-embedded thermoplastic microdevice integrating additive-enhanced allele-specific amplification and silver nanoparticle-based colorimetric detection for point-of-care testing. Lab Chip 2023; 23:5081-5091. [PMID: 37929914 DOI: 10.1039/d3lc00739a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Abstract
This study introduces a thermoplastic microdevice integrated with additive-enhanced allele-specific amplification and hydrazine-induced silver nanoparticle-based detection of single nucleotide polymorphism (SNP) and opportunistic pathogens. For point-of-care testing of SNP, an allele-specific loop-mediated isothermal amplification reaction using nucleotide-mismatched primers and molecular additives was evaluated to discriminate single-nucleotide differences in the samples. The microdevice consists of purification and reaction units that enable DNA purification, amplification, and detection in a sequential manner. The purification unit enables the silica-based preparation of samples using an embedded glass fiber membrane. Hydrazine-induced silver nanoparticle formation was employed for endpoint colorimetric detection of amplicons within three min at room temperature. The versatile applicability of the microdevice was demonstrated by the successful identification of SNPs related to sickle cell anemia, genetically-induced hair loss, and Enterococcus faecium. The microdevice exhibited a detection limit of 103 copies per μL of SNP targets in serum and 102 CFU mL-1 of Enterococcus faecium in tap water within 70 min. The proposed microdevice is a promising and versatile platform for point-of-care nucleic acid testing of different samples in low-resource settings.
Collapse
Affiliation(s)
- Duc Anh Thai
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| | - Seung Kyun Park
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| |
Collapse
|
6
|
Thai DA, Lee NY. A point-of-care platform for hair loss-related single nucleotide polymorphism genotyping. Anal Chim Acta 2023; 1283:341973. [PMID: 37977768 DOI: 10.1016/j.aca.2023.341973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/21/2023] [Accepted: 10/26/2023] [Indexed: 11/19/2023]
Abstract
Rapid genotyping of single nucleotide polymorphism (SNP) is crucial for prognostics and disease management, enabling more rapid therapy selection and treatment determination. Here, we introduce a point-of-care platform for hair loss-related SNP genotyping based on allele-specific loop-mediated isothermal amplification (AS-LAMP) combined with naked-eye visualization. The specificity of the AS-LAMP assay was significantly enhanced by using mismatched allele-specific primers. AS-LAMP reaction and Schiff's reagent-based colorimetric detection were successfully performed using a thermoplastic genotyping chip. This strategy also showed potential for determining homozygotes and heterozygotes in a target sample. To assess SNP genotyping capacity, the genotyping chip was fabricated to visually detect rs6152 polymorphism of an androgen receptor gene associated with genetically induced hair loss. The genotyping platform rapidly identified the SNP within 40 min, and the detection limit was as low as 1 pg/μL of the target DNA contained in human serum. The introduced strategy showed high specificity and stability in discriminating low-abundance mutations, making it suitable as a portable and affordable point-of-care platform for rapid and accurate SNP discrimination applicable for bedside detection.
Collapse
Affiliation(s)
- Duc Anh Thai
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
7
|
Nguyen HA, Lee NY. Pipette-Free and Fully Integrated Paper Device Employing DNA Extraction, Isothermal Amplification, and Carmoisine-Based Colorimetric Detection for Determining Infectious Pathogens. Sensors (Basel) 2023; 23:9112. [PMID: 38005500 PMCID: PMC10675313 DOI: 10.3390/s23229112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 11/07/2023] [Accepted: 11/09/2023] [Indexed: 11/26/2023]
Abstract
A pipette-free and fully integrated device that can be used to accurately recognize the presence of infectious pathogens is an important and useful tool in point-of-care testing, particularly when aiming to decrease the unpredictable threats posed by disease outbreak. In this study, a paper device is developed to integrate the three main processes required for detecting infectious pathogens, including DNA extraction, loop-mediated isothermal amplification (LAMP), and detection. All key reagents, including sodium dodecyl sulfate (SDS), NaOH, LAMP reagents, and carmoisine, are placed on the paper device. The paper device is operated simply via sliding and folding without using any bulky equipment, and the results can be directly observed by the naked eye. The optimized concentrations of sodium dodecyl sulfate (SDS), sodium hydroxide (NaOH), and carmoisine were found to be 0.1%, 0.1 M, and 0.5 mg/mL, respectively. The paper device was used to detect Enterococcus faecium at concentrations as low as 102 CFU/mL within 60 min. Also, E. faecium spiked in milk was successfully detected using the paper device, demonstrating the feasible application in real sample analysis.
Collapse
Affiliation(s)
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea;
| |
Collapse
|
8
|
Arumugam SS, Varghese AW, Suresh Nair S, Lee NY. Carbon-dot-triggered aggregation/dispersion of gold nanoparticles for colorimetric detection of nucleic acids and its application in visualization of loop-mediated isothermal amplification. Anal Methods 2023; 15:5793-5802. [PMID: 37853745 DOI: 10.1039/d3ay01336g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
In this study, cationic carbon dots (CDs) were prepared from p-phenylenediamine (pPDA) via a one-step hydrothermal method and used to trigger the aggregation and dispersion of gold nanoparticles (AuNPs) for the colorimetric detection of nucleic acids. Physicochemical characterization results revealed that the CDs are enriched with positively charged surface functional groups with an average size of ∼11 nm. The interaction between the CDs and AuNPs was confirmed via fluorescence and absorption studies. Absorption spectroscopic results revealed that the primary surface plasmon resonance (SPR) band of the AuNPs decreased upon introduction of CDs, and a new band emerged at ∼600 nm, indicating the aggregated assembly of AuNPs. Upon the introduction of double-stranded deoxyribonucleic acid (DNA), the band corresponding to the aggregated AuNPs showed a continuous decrease, accompanied by a simultaneous increase in the primary SPR band, leading to a noticeable purple-to-red color transformation. Based on this phenomenon, a colorimetric assay for DNA was developed, which relies on the interaction between negatively charged DNA and cationic CDs, leaving the AuNPs dispersed. The assay exhibited a linear response within a DNA concentration range of 0.7-14 nM with a detection limit of 1.70 nM. Selectivity results showed that colorimetric assays are specific for both DNA and single-stranded DNA (ssDNA). Smartphone-assisted detection was developed by monitoring the colorimetric response of a AuNPs/CDs probe. As a proof-of-concept experiment, the AuNPs/CDs probe was used to visualize the loop-mediated isothermal amplification (LAMP) of Escherichia coli (E. coli), a robust indicator of sewage contamination in water.
Collapse
Affiliation(s)
- Selva Sharma Arumugam
- Department of Nanoscience and Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea
| | - Amal Wilson Varghese
- Division of Molecular Medicine, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, 695012, India
| | - Swathy Suresh Nair
- Division of Molecular Medicine, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, 695012, India
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea.
| |
Collapse
|
9
|
Raab GT, Yu Y, Sherman E, Wong RJ, Mell LK, Lee NY, Zakeri K. Nomogram to Predict Risk of Early Mortality Following Definitive or Adjuvant Radiation and Systemic Therapy for Head and Neck Cancer. Int J Radiat Oncol Biol Phys 2023; 117:e617. [PMID: 37785852 DOI: 10.1016/j.ijrobp.2023.06.1997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) Tools to predict individual patient risk for early mortality in head and neck cancer patients receiving chemoradiation are lacking. We sought to create a nomogram to predict individual risk of early mortality, which may help identify patients who require interventions to prevent early death. MATERIALS/METHODS We included patients in the National Cancer Database with non-metastatic squamous cell carcinoma of the head and neck who received radiation and systemic therapy between 2004 and 2017 in either the definitive or adjuvant setting. Covariates analyzed in the cohort include race, gender, income, age, T and N category, tumor site, insurance type, facility type, urban or rural environment, radiation modality, and comorbidity. Early mortality was defined as any death less than 90 days after the beginning of radiation. Chi-squared analysis was used for all categorical covariates and t-tests were used for continuous variables to test for associations with early mortality. Multivariable logistic regression was used to assess the relationship between covariates and early mortality. Nomograms to predict the risk of early death were created for both the definitive and adjuvant settings. RESULTS The final cohorts included 84,563 patients in the definitive group and 18,514 patients in the adjuvant group. Rates of early mortality were 3.5% (95% CI 3.4-3.7%) and 2.2% (95% CI 1.9-2.4%) in the definitive and adjuvant cohorts, respectively. Patients above the age of 70 had an early mortality rate of 7.8% (95% CI 7.3-8.2%) in the definitive group and 4.4% (95% CI 3.6-5.4%) in the adjuvant group. In the multivariable analysis, age, comorbidity, T and N category, and tumor site were associated with early mortality in both cohorts (p<0.05 for all); while in the definitive group, radiation type, year of diagnosis, and insurance status were also statistically significant (p<0.05). In both cohorts, nomograms were created to predict the risk of early mortality that included age, comorbidity, T and N category and tumor site. The nomogram including age, comorbidity, T and N category and tumor site performed better than age alone at predicting early mortality (AUC for definitive group: 0.70 vs 0.66; AUC for adjuvant group: 0.71 vs 0.61). CONCLUSION Nomograms including age, comorbidity, T and N category and tumor site were developed to predict the risk of early death following definitive or adjuvant chemoradiation.
Collapse
Affiliation(s)
- G T Raab
- Weill Cornell Medical School, New York, NY
| | - Y Yu
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - E Sherman
- Department of Medical Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - R J Wong
- Memorial Sloan Kettering Cancer Center, Department of Head and Neck Surgery, New York, NY
| | - L K Mell
- University of California San Diego, La Jolla, CA
| | - N Y Lee
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - K Zakeri
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| |
Collapse
|
10
|
Lin H, Yu F, Gorovets D, Kabarriti R, Alektiar KM, Ohri N, Hasan S, Tsai P, Shim A, Kang M, Barker CA, Wolden SL, Hajj C, Mehta KJ, Lee NY, Chhabra AM, Shepherd AF, Choi IJ, Yamada Y, Simone CB. Pencil Beam Scanning Proton Stereotactic Body Radiation Therapy (SBRT): A Robust Single Institution Experience. Int J Radiat Oncol Biol Phys 2023; 117:e686-e687. [PMID: 37786018 DOI: 10.1016/j.ijrobp.2023.06.2155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) To describe the feasibility of treating a complex and diverse group of patients using pencil beam scanning (PBS) proton stereotactic body radiation therapy (SBRT: 5 or fewer fractions, with a fraction size of at least 5 Gy). MATERIALS/METHODS Our center treats on average 105-120 PBS proton treatments daily, of which 9.5% of treatment courses are proton SBRT. Statistics of disease sites, treatment planning parameters (target volume, prescriptions, number of fields, SFO vs. MFO), and treatment efficiencies (scheduled time slots, actual treatment time) are presented for 305 consecutive SBRT patients receiving 1507 fractions in the past three years. Thermoplastic masks or Vacuum-lock bags are used to immobilize SBRT patients and index the patients' treatment position. Imaging guidance of orthogonal kV images and volumetric cone-beam CT is routinely used for patient setup. RESULTS SBRT patients are grouped based on the target locations: pelvis (31%), liver (17%), thoracic (13%), spine (8%), abdominal (8%), brain (7%), non-spine bone (7%), ocular (6%), and head and neck (2%). Only 112 patients (37%) were receiving their 1st RT course, whereas 113 (37%) had one prior in-field RT course, and 80 (26%) had multiple prior in-field RT courses. The median [IQR] target volume was 65.4 [29.3, 168] cc (range: 0.3-2475 cc). 72% of cases were planned with SFO and 28% with MFO. On average, 3.76 fields (range: 2 to 12) were planned for each treatment. 44% of the treatments were planned with three or fewer fields, and 10% received more than five fields, most of which involved repainting for moving targets. Over 97% of treatments were delivered in 5 fractions, with ∼3% delivered in 3 fractions. The median [IQR] prescription per treatment was 8 [7, 10] Gy (range: 5-18 Gy per treatment). 85% (84%) of the SBRT treatments were scheduled (delivered) in a 45-minute or shorter slot, and 6% (7%) of treatments were scheduled (delivered) in over a one-hour slot, most commonly for multiple isocenter treatments. 93% of treatments were delivered within 15 minutes of the planned treatment time or shorter. Deep-inspiration breath-hold (DIBH) was applied to 45% of liver SBRT cases, with the remaining 55% planned on 4D CT with (14%) or without (86%) abdominal compression. DIBH was applied in 13% of lung SBRT cases. The application of other motion mitigation approaches, such as volumetric repainting, was determined by the target motion amplitude and whether the patient could tolerate DIBH. CONCLUSION In the most diverse and largest proton SBRT experience delivered in the world over the past 3 years, over 300 patients were treated, demonstrating the feasibility and efficiency of delivering proton SBRT in a very busy center. The planning and treatment parameter statistics reported serve as a helpful reference for the proton community.
Collapse
Affiliation(s)
- H Lin
- New York Proton Center, New York, NY; Memorial Sloan Kettering Cancer Center, New York, NY
| | - F Yu
- New York Proton Center, New York, NY
| | - D Gorovets
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - R Kabarriti
- Department of Radiation Oncology, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, NY
| | - K M Alektiar
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - N Ohri
- Department of Radiation Oncology, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, NY
| | - S Hasan
- New York Proton Center, New York, NY; Department of Radiation Oncology, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, NY
| | - P Tsai
- New York Proton Center, New York, NY
| | - A Shim
- New York Proton Center, New York, NY
| | - M Kang
- New York Proton Center, New York, NY
| | - C A Barker
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - S L Wolden
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - C Hajj
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - K J Mehta
- Department of Radiation Oncology, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, NY
| | - N Y Lee
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - A M Chhabra
- New York Proton Center, New York, NY; Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, NY
| | - A F Shepherd
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - I J Choi
- New York Proton Center, New York, NY; Memorial Sloan Kettering Cancer Center, New York, NY
| | - Y Yamada
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - C B Simone
- New York Proton Center, New York, NY; Memorial Sloan Kettering Cancer Center, New York, NY
| |
Collapse
|
11
|
Mohamed N, Mattessich SP, Gelblum D, Lee NY, Barker CA. Radiotherapy (RT) for Cutaneous Adnexal Carcinoma (CAC): 49 Patients Treated at a Single Institution Over 2 Decades. Int J Radiat Oncol Biol Phys 2023; 117:e607-e608. [PMID: 37785828 DOI: 10.1016/j.ijrobp.2023.06.1978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) Cutaneous adnexal carcinomas (CACs) are a heterogenous group of rare skin cancers. Management strategies are extrapolated from the treatment of more common skin cancers, and case series describing patients treated with radiotherapy (RT) for CAC are limited to <15 patients. We reviewed our institutional experience to better understand the characteristics and outcomes of patients with CAC treated with RT. MATERIALS/METHODS Patients diagnosed with CAC and treated RT from 2000-2020 were identified using the following keywords: adnexal, microcystic, apocrine, eccrine, sebaceous, sweat gland, syringoma, mucinous, tubular, porocarcinoma, hidradenocarcinoma, and cylindrocarcinoma. Patient, cancer, and treatment characteristics were assessed by retrospective record review. Time to overall survival (OS), locoregional recurrence (LRR), distant metastasis (DM), and progression free survival (PFS) were evaluated using Kaplan-Meier methods. RESULTS Forty-nine patients with a median age of 65 years (IQR 53-82) were identified. Most were white (90%) men (59%) harboring tumors on the head and neck (80%). The most common subtypes of CAC were adnexal adenocarcinoma (39%), sebaceous carcinoma (35%) and microcystic adnexal carcinoma (10%). Patients were treated for de novo cancer (n = 35) or after recurrence (n = 14). Among de novo cases, 9 (26%) were treated with definitive RT, 22 (63%) were treated with surgery and adjuvant RT, and 4 (11%) with palliative RT. Per UICC system, de novo stage at time of RT was I in 2 (6%), II in 9 (26%), III in 12 (34%), IVA in 10 (29%), and IVB in 2 (6%). Median OS was 44 months and median follow-up of surviving patients was 41 months (IQR 17-75). De novo patients treated with definitive RT received a median dose of 70 Gy (IQR 60-73 Gy) and experienced 2-year rates of PFS, LRR, and DM of 30%, 55%, and 40%, respectively. All LRR events occurred within the irradiated volume. De novo patients treated with surgery and adjuvant RT received a median dose of 60 Gy (IQR 60-64 Gy) and experienced 2-year rates of PFS, LRR, and DM of 77%, 13%, and 10%, respectively. All LRR events occurred outside the irradiated volume. Among patients treated at recurrence, most (93%) underwent surgery and adjuvant RT. Per UICC system, their stage at time of RT was II in 2 (15.4%), III in 4 (30.8%), and IVA in 7 (53.8%). Recurrent patients treated with surgery and adjuvant RT received a median dose of 60 Gy (IQR 60-66 Gy) and experienced 2-year rates of PFS, LRR, and DM of 30%, 58%, and 29%, respectively. Three of 4 evaluable patients treated with palliative RT exhibited stable disease or tumor response. CONCLUSION In the largest single institution analysis to date, RT was primarily used for CAC patients as an adjuvant treatment. LRR was less frequent and less likely to occur within irradiated volume in patients selected for surgery and adjuvant RT than those selected for definitive RT or at time of recurrence.
Collapse
Affiliation(s)
- N Mohamed
- Memorial Sloan Kettering Cancer Center, New York, NY
| | | | - D Gelblum
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - N Y Lee
- Memorial Sloan Kettering Cancer Center, New York, NY
| | - C A Barker
- Memorial Sloan Kettering Cancer Center, New York, NY
| |
Collapse
|
12
|
Shang T, Raab G, Chen L, Yu Y, Shamseddine A, Riaz N, McBride SM, Gelblum D, Lee NY, Zakeri K. Impact of Surveillance Imaging in Patients with HPV-Associated Oropharyngeal Carcinomas Treated with Definitive Radiation and Chemotherapy. Int J Radiat Oncol Biol Phys 2023; 117:e624. [PMID: 37785868 DOI: 10.1016/j.ijrobp.2023.06.2011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) Post-treatment surveillance imaging for HPV-associated oropharyngeal carcinomas (OPCs) differs among physicians and institutions. Surveillance imaging can detect disease progression earlier, but can also contribute to anxiety and cost, without proven disease-free or survival benefit. We sought to determine the number of surveillance scans needed to detect a recurrence in patients with HPV-associated OPCs. MATERIALS/METHODS We included consecutive patients with locally advanced HPV-associated OPC that received definitive concurrent chemoradiotherapy (CRT) with 70 Gy between March 1, 2017 to July 31, 2019. First post-treatment scans were defined as the first scans following the end of CRT. Surveillance scans were defined as body FDG PET/CTs, neck or chest CTs, and neck MRIs taken after the first post-treatment scans showed no evidence of disease. Any scans ordered to follow suspicious lesions on first post-treatment scans were not counted as surveillance scans. Recurrences were classified as detected by first post-treatment scans, surveillance scans, clinical exam, or incidental findings. The number of surveillance scans needed to detect 1 recurrence was determined by dividing the number of surveillance scans by the number of recurrences detected by surveillance scans. RESULTS There were a total of 275 patients with median follow-up of 39.8 months (Interquartile Range (IQR), 34.9-47.8). Surveillance scans were first taken at a median of 12.1 months (IQR, 9.2-16) post-CRT. There were 27 (9.8%) patients who had a recurrence: 7 (2.5%) had locoregional recurrence (LR), 19 (6.9%) had distant metastasis (DM), and 1 (0.4%) had both LR and DM. LR was detected at a median of 5.8 months (IQR, 3.4-10.6) post-CRT and DM was detected at a median of 9.5 months (IQR, 4.8-14.3) post-CRT. Of all recurrences, 11/27 (40.7%) were first post-treatment scan detected, 10 (37.0%) were surveillance scan detected, 5 (18.5%) were clinical exam detected, and 1 (3.7%) was incidentally detected on lung cancer screening. Four (50%) LRs were first post-treatment detected (median time to detection, MTD: 4.2 months), 3 (37.5%) were clinical exam detected (MTD: 6.7 months), and 1 (12.5%) was surveillance detected (MTD: 9.0 months). For DM, 9 (45%) were surveillance detected (MTD: 12.7 months), 8 (40%) were first post-treatment detected (MTD: 4.1 months), 2 (10%) were clinical exam detected (MTD: 18.9 months), and 1 (5%) was incidentally detected (MTD: 12.1 months). A total of 702 surveillance scans were taken during the follow-up period. The number of surveillance scans needed to detect 1 LR/DM was 71 overall, 50 within 2 years and 254 beyond 2 years from CRT. CONCLUSION First post treatment scans detect most recurrences for HPV-associated OPC. A high burden of surveillance scans is needed to detect one recurrence, especially beyond 2 years from CRT.
Collapse
Affiliation(s)
- T Shang
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - G Raab
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - L Chen
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Y Yu
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - A Shamseddine
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - N Riaz
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - S M McBride
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - D Gelblum
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - N Y Lee
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - K Zakeri
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| |
Collapse
|
13
|
Trinh KTL, Thai DA, Yang DH, Lee NY. Chitosan: a green adhesive for surface functionalization and fabrication of thermoplastic biomedical microdevices. Lab Chip 2023; 23:4245-4254. [PMID: 37655654 DOI: 10.1039/d3lc00500c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
Chitosan (CS) is a natural polymer that exhibits many biological properties and is used as a biomaterial for antibacterial coatings, tissue engineering, cell research, drug delivery, and negatively charged molecule capture. In our previous study, we used a CS-polydopamine mixture to realize UV-assisted bonding between poly(methyl methacrylate) (PMMA) substrates to fabricate microdevices for self-assembled stem cell spheroid cultures. Herein, we attained reliable adhesive bonding between PMMAs using CS at room temperature assisted by oxygen plasma. The bond strength of adhesion was as high as 2.1 MPa, which could be stable for over two months according to the leak test. The adhesive bonding and surface functionalization of the microchannels were simultaneously completed such that the microdevices could be directly used for mesenchymal stem cell culture for spheroid generation and DNA purification for point-of-care testing (POCT) devices. Surface characterization was performed by contact angle measurements, Fourier-transform infrared spectroscopy, scanning electron microscopy, and atomic force microscopy. The POCT device allows sequential on-chip DNA purification, amplification, and colorimetric detection of pathogenic bacteria. This method provides a convenient and reliable strategy for the fabrication of PMMA microdevices that can be directly implemented in biological studies and POCT applications without involving prior surface modification steps.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea
| | - Duc Anh Thai
- Department of BioNano Technology, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| | - Da Hyun Yang
- Department of BioNano Technology, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| |
Collapse
|
14
|
Trinh TND, Do HDK, Nam NN, Dan TT, Trinh KTL, Lee NY. Droplet-Based Microfluidics: Applications in Pharmaceuticals. Pharmaceuticals (Basel) 2023; 16:937. [PMID: 37513850 PMCID: PMC10385691 DOI: 10.3390/ph16070937] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 06/19/2023] [Accepted: 06/25/2023] [Indexed: 07/30/2023] Open
Abstract
Droplet-based microfluidics offer great opportunities for applications in various fields, such as diagnostics, food sciences, and drug discovery. A droplet provides an isolated environment for performing a single reaction within a microscale-volume sample, allowing for a fast reaction with a high sensitivity, high throughput, and low risk of cross-contamination. Owing to several remarkable features, droplet-based microfluidic techniques have been intensively studied. In this review, we discuss the impact of droplet microfluidics, particularly focusing on drug screening and development. In addition, we surveyed various methods of device fabrication and droplet generation/manipulation. We further highlight some promising studies covering drug synthesis and delivery that were updated within the last 5 years. This review provides researchers with a quick guide that includes the most up-to-date and relevant information on the latest scientific findings on the development of droplet-based microfluidics in the pharmaceutical field.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Materials Science, School of Applied Chemistry, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 70000, Vietnam
| | - Nguyen Nhat Nam
- Biotechnology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Thach Thi Dan
- Department of Materials Science, School of Applied Chemistry, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
15
|
Sivakumar R, Lee NY. Advances in deoxyribonucleic acid extraction techniques and point-of-care molecular diagnosis of foodborne pathogens. Analyst 2023. [PMID: 37351846 DOI: 10.1039/d3an00045a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
A conventional molecular assay-based point-of-care (POC) diagnostic test involves three major stages: deoxyribonucleic acid (DNA) extraction, amplification, and amplicon detection. Among these steps, DNA extraction is costly and time-consuming. Nevertheless, it is a crucial step for the identification of sensitive and specific diseases. This review summarizes the advantages and disadvantages of DNA extraction methods over the past 10 years to effectively implement POC pathogen testing in the future. The first section briefly explains the necessity of DNA extraction and molecular assays for food pathogen detection. The second section extensively discusses DNA extraction based on liquid-liquid extraction, solid-phase extraction, and electrophoretic techniques. Molecular assay-based methods and a few commercially available POC devices for the detection of foodborne pathogens are detailed in the third and fourth sections. Finally, present challenges and future perspectives for the fabrication of integrated POC devices are highlighted.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, Korea.
| |
Collapse
|
16
|
Nam NN, Do HDK, Loan Trinh KT, Lee NY. Metagenomics: An Effective Approach for Exploring Microbial Diversity and Functions. Foods 2023; 12:foods12112140. [PMID: 37297385 DOI: 10.3390/foods12112140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 05/21/2023] [Accepted: 05/24/2023] [Indexed: 06/12/2023] Open
Abstract
Various fields have been identified in the "omics" era, such as genomics, proteomics, transcriptomics, metabolomics, phenomics, and metagenomics. Among these, metagenomics has enabled a significant increase in discoveries related to the microbial world. Newly discovered microbiomes in different ecologies provide meaningful information on the diversity and functions of microorganisms on the Earth. Therefore, the results of metagenomic studies have enabled new microbe-based applications in human health, agriculture, and the food industry, among others. This review summarizes the fundamental procedures on recent advances in bioinformatic tools. It also explores up-to-date applications of metagenomics in human health, food study, plant research, environmental sciences, and other fields. Finally, metagenomics is a powerful tool for studying the microbial world, and it still has numerous applications that are currently hidden and awaiting discovery. Therefore, this review also discusses the future perspectives of metagenomics.
Collapse
Affiliation(s)
- Nguyen Nhat Nam
- Biotechnology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 72820, Vietnam
| | - Kieu The Loan Trinh
- Department of BioNano Technology, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
17
|
Park SY, Chae DS, Lee JS, Cho BK, Lee NY. Point-of-Care Testing of the MTF1 Osteoarthritis Biomarker Using Phenolphthalein-Soaked Swabs. Biosensors (Basel) 2023; 13:bios13050535. [PMID: 37232895 DOI: 10.3390/bios13050535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/06/2023] [Accepted: 05/08/2023] [Indexed: 05/27/2023]
Abstract
Osteoarthritis (OA) is the most common joint disease, which accompanies pain and inconvenience in daily life owing to degradation of cartilage and adjacent tissues. In this study, we propose a simple point-of-care testing (POCT) kit for the detection of the MTF1 OA biomarker to achieve on-site clinical diagnosis of OA. The kit contains an FTA card for patient sample treatments, a sample tube for loop-mediated isothermal amplification (LAMP), and a phenolphthalein-soaked swab for naked eye detection. The MTF1 gene was isolated from synovial fluids using an FTA card and amplified using the LAMP method at 65 °C for 35 min. A test part of the phenolphthalein-soaked swab was decolorized in the presence of the MTF1 gene due to the pH change after the LAMP, but the color remained pink in the absence of the MTF1 gene. The control part of the swab served as a reference color in relation to the test part. When real-time LAMP (RT-LAMP), gel electrophoresis, and colorimetric detection of the MTF1 gene were performed, the limit of detection (LOD) was confirmed at 10 fg/μL, and the overall processes were completed in 1 h. The detection of an OA biomarker in the form of POCT was reported for the first time in this study. The introduced method is expected to serve as a POCT platform directly applicable by clinicians for easy and rapid identification of OA.
Collapse
Affiliation(s)
- So Yeon Park
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| | - Dong-Sik Chae
- Department of Orthopedic Surgery, College of Medicine, Catholic Kwandong University, Incheon 21431, Republic of Korea
| | - Jae Sun Lee
- Chief Researcher, Healthcontents, Co., Ltd., Cheongju 28119, Republic of Korea
| | - Byung-Ki Cho
- Department of Orthopaedic Surgery, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
18
|
Trinh KTL, Do HDK, Lee NY. Recent Advances in Molecular and Immunological Diagnostic Platform for Virus Detection: A Review. Biosensors (Basel) 2023; 13:bios13040490. [PMID: 37185566 PMCID: PMC10137144 DOI: 10.3390/bios13040490] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/14/2023] [Accepted: 04/18/2023] [Indexed: 05/17/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused an ongoing coronavirus disease (COVID-19) outbreak and a rising demand for the development of accurate, timely, and cost-effective diagnostic tests for SARS-CoV-2 as well as other viral infections in general. Currently, traditional virus screening methods such as plate culturing and real-time PCR are considered the gold standard with accurate and sensitive results. However, these methods still require sophisticated equipment, trained personnel, and a long analysis time. Alternatively, with the integration of microfluidic and biosensor technologies, microfluidic-based biosensors offer the ability to perform sample preparation and simultaneous detection of many analyses in one platform. High sensitivity, accuracy, portability, low cost, high throughput, and real-time detection can be achieved using a single platform. This review presents recent advances in microfluidic-based biosensors from many works to demonstrate the advantages of merging the two technologies for sensing viruses. Different platforms for virus detection are classified into two main sections: immunoassays and molecular assays. Moreover, available commercial sensing tests are analyzed.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 70000, Vietnam
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| |
Collapse
|
19
|
Nam NN, Do HDK, Trinh KTL, Lee NY. Design Strategy and Application of Deep Eutectic Solvents for Green Synthesis of Nanomaterials. Nanomaterials (Basel) 2023; 13:1164. [PMID: 37049256 PMCID: PMC10096871 DOI: 10.3390/nano13071164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/12/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
The first report of deep eutectic solvents (DESs) was released in 2003 and was identified as a new member of ionic liquid (IL), involving innovative chemical and physical characteristics. Using green solvent technology concerning economical, practical, and environmental aspects, DESs open the window for sustainable development of nanomaterial fabrication. The DESs assist in different fabrication processes and design nanostructures with specific morphology and properties by tunable reaction conditions. Using DESs in synthesis reactions can reduce the required high temperature and pressure conditions for decreasing energy consumption and the risk of environmental contamination. This review paper provides the recent applications and advances in the design strategy of DESs for the green synthesis of nanomaterials. The strategy and application of DESs in wet-chemical processes, nanosize reticular material fabrication, electrodeposition/electrochemical synthesis of nanostructures, electroless deposition, DESs based nano-catalytic and nanofluidic systems are discussed and highlighted in this review.
Collapse
Affiliation(s)
- Nguyen Nhat Nam
- Biotechnology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 700000, Vietnam
| | - Kieu The Loan Trinh
- Department of BioNano Technology, Gachon University, 1342 Seongnam-Daero, Sujeong-Gu, Seongnam-Si 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-Daero, Sujeong-Gu, Seongnam-Si 13120, Republic of Korea
| |
Collapse
|
20
|
Sivakumar R, Park SY, Lee NY. Quercetin-Mediated Silver Nanoparticle Formation for the Colorimetric Detection of Infectious Pathogens Coupled with Loop-Mediated Isothermal Amplification. ACS Sens 2023; 8:1422-1430. [PMID: 36952605 DOI: 10.1021/acssensors.2c02054] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2023]
Abstract
Here, quercetin-mediated silver nanoparticle (AgNP) formation combined with loop-mediated isothermal amplification (LAMP) was introduced to colorimetrically detect two major infectious pathogens, SARS-CoV-2 and Enterococcus faecium, using a foldable PMMA microdevice. The nitrogenous bases of LAMP amplicons can readily form a complex with Ag+ ions, and the catechol moiety in quercetin, which acted as a reducing agent, could be chelated with Ag+ ions, resulting in the easy electron transfer from the oxidant to the reductant and producing brown-colored AgNPs within 5 min. The introduced method exhibited higher sensitivity than agarose gel electrophoresis due to more active redox centers in quercetin. The detection limit was attained at 101 copies μL-1 and 101 CFU mL-1 for SARS-CoV-2 RNA and E. faecium, respectively. A foldable microdevice made of two pieces of PMMA that fully integrates DNA extraction, amplification, and detection processes was fabricated to establish practical applicability. On one PMMA, DNA extraction was performed in a reaction chamber inserted with an FTA card, and then LAMP reagents were added for amplification. Silver nitrate was added to the reaction chamber after LAMP. On the other PMMA, quercetin-soaked paper discs loaded in the detection chamber were folded toward the reaction chamber for colorimetric detection. An intense brown color was produced within 5 min when heated at 65 °C. The introduced colorimetric assay, which is highly favorable for laboratory and on-site applications, could be a valuable alternative to conventional methods for detecting infectious diseases, given its unique principle, simplicity, and naked-eye detection.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea
| | - So Yeon Park
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, South Korea
| |
Collapse
|
21
|
Pham HL, Yang DH, Chae WR, Jung JH, Hoang TX, Lee NY, Kim JY. PDMS Micropatterns Coated with PDA and RGD Induce a Regulatory Macrophage-like Phenotype. Micromachines (Basel) 2023; 14:673. [PMID: 36985080 PMCID: PMC10052727 DOI: 10.3390/mi14030673] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/14/2023] [Accepted: 03/16/2023] [Indexed: 06/18/2023]
Abstract
Regulatory macrophages (Mreg) are a special cell type that present a potential therapeutic strategy for various inflammatory diseases. In vitro, Mreg generation mainly takes 7-10 days of treatment with chemicals, including cytokines. In the present study, we established a new approach for Mreg generation using a three-dimensional (3D) micropatterned polydimethylsiloxane (PDMS) surface coated with a natural biopolymer adhesive polydopamine (PDA) and the common cell adhesion peptide motif arginylglycylaspartic acid (RGD). The 3D PDMS surfaces were fabricated by photolithography and soft lithography techniques and were subsequently coated with an RGD+PDA mixture to form a surface that facilitates cell adhesion. Human monocytes (THP-1 cells) were cultured on different types of 2D or 3D micropatterns for four days, and the cell morphology, elongation, and Mreg marker expression were assessed using microscopic and flow cytometric analyses. The cells grown on the PDA+RGD-coated 3D micropatterns (20-µm width/20-µm space) exhibited the most elongated morphology and strongest expression levels of Mreg markers, such as CD163, CD206, CD209, CD274, MER-TK, TREM2, and DHRS9. The present study demonstrated that PDA+RGD-coated 3D PDMS micropatterns successfully induced Mreg-like cells from THP-1 cells within four days without the use of cytokines, suggesting a time- and cost-effective method to generate Mreg-like cells in vitro.
Collapse
Affiliation(s)
- Hoang Lan Pham
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-Do, Republic of Korea
| | - Da Hyun Yang
- Department of BioNano Technology, Gachon University, Seongnam 13120, Gyeonggi-Do, Republic of Korea
| | - Woo Ri Chae
- Department of BioNano Technology, Gachon University, Seongnam 13120, Gyeonggi-Do, Republic of Korea
| | - Jong Hyeok Jung
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-Do, Republic of Korea
| | - Thi Xoan Hoang
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-Do, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, Seongnam 13120, Gyeonggi-Do, Republic of Korea
| | - Jae Young Kim
- Department of Life Science, Gachon University, Seongnam 13120, Gyeonggi-Do, Republic of Korea
| |
Collapse
|
22
|
Nguyen HA, Lee NY. Copper: DNA extraction and solid phase detection agent for all-in-one molecular diagnostic device coupled with isothermal amplification. Biosens Bioelectron 2023; 229:115222. [PMID: 36989581 DOI: 10.1016/j.bios.2023.115222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/28/2023] [Accepted: 03/09/2023] [Indexed: 03/14/2023]
Abstract
In this study, an all-in-one poly(methyl methacrylate) (PMMA) device integrating two novel techniques - DNA extraction employing a CuSO4/H2O2 system and DNA detection utilizing solid phase copper tape - coupled with loop-mediated isothermal amplification (LAMP) is developed for on-site pathogen detection. The CuSO4/H2O2 system, also known as Fenton-like reaction, is used to produce hydroxyl radicals, which can disrupt bacterial membranes via lipid peroxidation and release DNA at room temperature. The released DNA is subsequently amplified by LAMP reaction. The acidic environment resulting from the production of hydrogen ions in the presence of target DNA in the LAMP reaction can stimulate the color change on copper tape due to the corrosion, while the innate alkaline environment in a negative sample not containing target DNA cannot stimulate the corrosion. The fabricated PMMA device integrates all the functionalities necessary for molecular diagnostics such as DNA extraction, amplification, and detection, and a carbon paste-based heater is fabricated for LAMP reaction. Using the PMMA device, Enterococcus faecium was detected as low as 4.67 × 102 CFU/mL within 90 min. E. faecium spiked in milk was successfully detected using the all-in-one PMMA device. The equipment-free techniques for decentralized diagnostics and naked-eye readout of results coupled with the portable heater serves as a promising solution for point-of-care testing particularly in a resource-limited environment.
Collapse
Affiliation(s)
- Hanh An Nguyen
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
23
|
Manikandan V, Lee NY. Reduced graphene oxide: Biofabrication and environmental applications. Chemosphere 2023; 311:136934. [PMID: 36273614 DOI: 10.1016/j.chemosphere.2022.136934] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 10/04/2022] [Accepted: 10/16/2022] [Indexed: 06/16/2023]
Abstract
Green synthesis of high-quality reduced graphene oxide (rGO) from agro-industrial waste resources remains attractive owing to its outstanding environmental benefits. The remarkable properties of rGO include excellent morphology, uniform particle size, good optical properties, high conductivity, nontoxicity, and extraordinary chemical stability. Traditional methods for the synthesis of rGO nanomaterials involve several chemical reactions including oxidation, carbonization, toxic solvent, and pyrolysis which produce harmful byproducts. Green preparation of rGO is an emerging area of research in graphene technology which is cost-effective and sustainable in the procedure. Owing to the uniform particle rGO particle size, these smart nanomaterials have wide applicability, including in metal ions and pollutant sensing and adsorption, photocatalysis, optoelectrical devices, medical diagnosis, and drug delivery. Here we review the physicochemical properties of rGO, the biowaste sources and green methods of rGO synthesis, and the diverse applications of rGO, including in water purification and the biomedical fields. With this review, covering more than 200 research articles published on rGO in the last eight years ending in 2022, we aim to provide a quick guide for researchers seeking up-to-date information on the properties, production, and applicability of rGO, with special attention to rGO applications in water purification and the biomedical fields.
Collapse
Affiliation(s)
- Velu Manikandan
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
24
|
Nam NN, Do HDK, Trinh KTL, Lee NY. Recent Progress in Nanotechnology-Based Approaches for Food Monitoring. Nanomaterials (Basel) 2022; 12:nano12234116. [PMID: 36500739 PMCID: PMC9740597 DOI: 10.3390/nano12234116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/17/2022] [Accepted: 11/20/2022] [Indexed: 05/10/2023]
Abstract
Throughout the food supply chain, including production, storage, and distribution, food can be contaminated by harmful chemicals and microorganisms, resulting in a severe threat to human health. In recent years, the rapid advancement and development of nanotechnology proposed revolutionary solutions to solve several problems in scientific and industrial areas, including food monitoring. Nanotechnology can be incorporated into chemical and biological sensors to improve analytical performance, such as response time, sensitivity, selectivity, reliability, and accuracy. Based on the characteristics of the contaminants and the detection methods, nanotechnology can be applied in different ways in order to improve conventional techniques. Nanomaterials such as nanoparticles, nanorods, nanosheets, nanocomposites, nanotubes, and nanowires provide various functions for the immobilization and labeling of contaminants in electrochemical and optical detection. This review summarizes the recent advances in nanotechnology for detecting chemical and biological contaminations in the food supply chain.
Collapse
Affiliation(s)
- Nguyen Nhat Nam
- Biotechnology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 70000, Vietnam
| | - Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
- Correspondence: (K.T.L.T.); (N.Y.L.)
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
- Correspondence: (K.T.L.T.); (N.Y.L.)
| |
Collapse
|
25
|
Trinh KTL, Lee NY. Recent Methods for the Viability Assessment of Bacterial Pathogens: Advances, Challenges, and Future Perspectives. Pathogens 2022; 11:pathogens11091057. [PMID: 36145489 PMCID: PMC9500772 DOI: 10.3390/pathogens11091057] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/14/2022] [Accepted: 09/15/2022] [Indexed: 11/28/2022] Open
Abstract
Viability assessment is a critical step in evaluating bacterial pathogens to determine infectious risks to public health. Based on three accepted viable criteria (culturability, metabolic activity, and membrane integrity), current viability assessments are categorized into three main strategies. The first strategy relies on the culturability of bacteria. The major limitation of this strategy is that it cannot detect viable but nonculturable (VBNC) bacteria. As the second strategy, based on the metabolic activity of bacteria, VBNC bacteria can be detected. However, VBNC bacteria sometimes can enter a dormant state that allows them to silence reproduction and metabolism; therefore, they cannot be detected based on culturability and metabolic activity. In order to overcome this drawback, viability assessments based on membrane integrity (third strategy) have been developed. However, these techniques generally require multiple steps, bulky machines, and laboratory technicians to conduct the tests, making them less attractive and popular applications. With significant advances in microfluidic technology, these limitations of current technologies for viability assessment can be improved. This review summarized and discussed the advances, challenges, and future perspectives of current methods for the viability assessment of bacterial pathogens.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
- Correspondence:
| |
Collapse
|
26
|
Trinh KTL, Thai DA, Lee NY. Bonding Strategies for Thermoplastics Applicable for Bioanalysis and Diagnostics. Micromachines (Basel) 2022; 13:1503. [PMID: 36144126 PMCID: PMC9501821 DOI: 10.3390/mi13091503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 09/05/2022] [Accepted: 09/08/2022] [Indexed: 06/16/2023]
Abstract
Microfluidics is a multidisciplinary science that includes physics, chemistry, engineering, and biotechnology. Such microscale systems are receiving growing interest in applications such as analysis, diagnostics, and biomedical research. Thermoplastic polymers have emerged as one of the most attractive materials for microfluidic device fabrication owing to advantages such as being optically transparent, biocompatible, cost-effective, and mass producible. However, thermoplastic bonding is a key challenge for sealing microfluidic devices. Given the wide range of bonding methods, the appropriate bonding approach should be carefully selected depending on the thermoplastic material and functional requirements. In this review, we aim to provide a comprehensive overview of thermoplastic fabricating and bonding approaches, presenting their advantages and disadvantages, to assist in finding suitable microfluidic device bonding methods. In addition, we highlight current applications of thermoplastic microfluidics to analyses and diagnostics and introduce future perspectives on thermoplastic bonding strategies.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
| | - Duc Anh Thai
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea
| |
Collapse
|
27
|
Manikandan V, Lee NY. Green synthesis of carbon quantum dots and their environmental applications. Environ Res 2022; 212:113283. [PMID: 35461844 DOI: 10.1016/j.envres.2022.113283] [Citation(s) in RCA: 39] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Revised: 04/07/2022] [Accepted: 04/08/2022] [Indexed: 05/25/2023]
Abstract
Green synthesis of scalable, high-quality, fluorescent carbon quantum dots (CQDs) from natural biomass remains attractive due to their outstanding environmental application. CQDs are an emerging class of zero-dimensional carbon nanomaterials (<10 nm) that have recently attracted much attention due to their strong optical properties, biocompatibility, nontoxicity, uniform particle size, high photostability, low-cost synthesis, and highly tunable photoluminescence. The unique properties of CQDs possess a broad range of prospective applications in a number of fields such as metal ions detection, photocatalysis, sensing, medical diagnosis, bioimaging, and drug delivery. CQD nanostructures are synthesized using various techniques such as hydrothermal method, laser ablation, microwave irradiation, electrochemical oxidation, reflux method, and ultrasonication. However, this type of fabrication approach requires several chemical reactions including oxidation, carbonization, and pyrolysis. Green synthesis of CQDs has several advantages such as the use of low-cost and non-toxic raw materials, renewable resources, simple operations, and being environment-friendly. This review article will discuss the physicochemical properties of CQDs techniques used in the production of CQDs, and the stability of CQDs along with their applications in wastewater treatment and biomedical fields.
Collapse
Affiliation(s)
- Velu Manikandan
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| |
Collapse
|
28
|
Trinh TND, Lee NY. Colorimetric detection of viable antibiotic resistant Enterococcus mediated by cordless operation of reverse transcription loop-mediated isothermal amplification. J Biotechnol 2022; 357:92-99. [PMID: 35952900 DOI: 10.1016/j.jbiotec.2022.08.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Revised: 07/12/2022] [Accepted: 08/05/2022] [Indexed: 11/20/2022]
Abstract
In this study, we applied a tube-based reverse transcription loop-mediated isothermal amplification technique using preloaded amplification and detection reagents for simple screening of viable vancomycin-resistant Enterococcus in a cordless manner. We adopted an mRNA-based approach to detect live Enterococcus in vancomycin-treated cultures. We used agarose to preload and store all reagents for amplification and detection inside the tube, which could achieve on-site isothermal nucleic acid amplification and detection in less than 1 h without using sophisticated instruments. Moreover, the use of a portable insulated water tumbler eliminated the need for electricity, which is usually important in nucleic acid amplification-based assays. The water tumbler acted as a heat source to supply a stable heat required for the amplification reaction, which could last up to 45 min. In addition, colorimetric detection was realized using pH-based methods. The detection was triggered by shaking the tube so that the amplified solution was reacted with phenolphthalein embedded in the tube cap. The introduced one-pot strategy has many advantages such as easy and cordless operation, low cost, disposability, and less chance of contamination because the amplification and detection occur in a closed system. The system could have a great impact on nucleic acid analyses in instrument-free and low-resource areas.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, the Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, the Republic of Korea.
| |
Collapse
|
29
|
Sivakumar R, Lee NY. Recent advances in airborne pathogen detection using optical and electrochemical biosensors. Anal Chim Acta 2022; 1234:340297. [PMID: 36328717 PMCID: PMC9395976 DOI: 10.1016/j.aca.2022.340297] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 07/27/2022] [Accepted: 08/18/2022] [Indexed: 11/30/2022]
Abstract
The world is currently facing an adverse condition due to the pandemic of airborne pathogen SARS-CoV-2. Prevention is better than cure; thus, the rapid detection of airborne pathogens is necessary because it can reduce outbreaks and save many lives. Considering the immense role of diverse detection techniques for airborne pathogens, proper summarization of these techniques would be beneficial for humans. Hence, this review explores and summarizes emerging techniques, such as optical and electrochemical biosensors used for detecting airborne bacteria (Bacillus anthracis, Mycobacterium tuberculosis, Staphylococcus aureus, and Streptococcus pneumoniae) and viruses (Influenza A, Avian influenza, Norovirus, and SARS-CoV-2). Significantly, the first section briefly focuses on various diagnostic modalities applied toward airborne pathogen detection. Next, the fabricated optical biosensors using various transducer materials involved in colorimetric and fluorescence strategies for infectious pathogen detection are extensively discussed. The third section is well documented based on electrochemical biosensors for airborne pathogen detection by differential pulse voltammetry, cyclic voltammetry, square-wave voltammetry, amperometry, and impedance spectroscopy. The unique pros and cons of these modalities and their future perspectives are addressed in the fourth and fifth sections. Overall, this review inspected 171 research articles published in the last decade and persuaded the importance of optical and electrochemical biosensors for airborne pathogen detection.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
30
|
Nguyen HA, Choi H, Lee NY. A Rotatable Paper Device Integrating Reverse Transcription Loop-Mediated Isothermal Amplification and a Food Dye for Colorimetric Detection of Infectious Pathogens. Biosensors 2022; 12:bios12070488. [PMID: 35884291 PMCID: PMC9313173 DOI: 10.3390/bios12070488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 06/24/2022] [Accepted: 06/28/2022] [Indexed: 11/17/2022]
Abstract
In this study, we developed a rotatable paper device integrating loop-mediated isothermal amplification (RT-LAMP) and a novel naked-eye readout of the RT-LAMP results using a food additive, carmoisine, for infectious pathogen detection. Hydroxyl radicals created from the reaction between CuSO4 and H2O2 were used to decolor carmoisine, which is originally red. The decolorization of carmoisine can be interrupted in the presence of DNA amplicons produced by the RT-LAMP reaction due to how DNA competitively reacts with the hydroxyl radicals to maintain the red color of the solution. In the absence of the target DNA, carmoisine is decolored, owing to its reaction with hydroxyl radicals; thus, positive and negative samples can be easily differentiated based on the color change of the solution. A rotatable paper device was fabricated to integrate the RT-LAMP reaction with carmoisine-based colorimetric detection. The rotatable paper device was successfully used to detect SARS-CoV-2 and SARS-CoV within 70 min using the naked eye. Enterococcus faecium spiked in milk was detected using the rotatable paper device. The detection limits for the SARS-CoV-2 and SARS-CoV targets were both 103 copies/µL. The rotatable paper device provides a portable and low-cost tool for detecting infectious pathogens in a resource-limited environment.
Collapse
|
31
|
Sivakumar R, Lee NY. Emerging bismuth-based direct Z-scheme photocatalyst for the degradation of organic dye and antibiotic residues. Chemosphere 2022; 297:134227. [PMID: 35259359 DOI: 10.1016/j.chemosphere.2022.134227] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 02/19/2022] [Accepted: 03/03/2022] [Indexed: 06/14/2023]
Abstract
Organic dye and antibiotic residues are some of the key substances that can contaminate the environment due to their wide usage in various industries and modern medicine. The degradation of these substances present in waterbodies is essential while contemplating human health. Photocatalysts (PSs) are promising materials that develop highly reactive species instantly by simple solar energy conversion for degrading the organic dye and antibiotic residues and converting them into nontoxic products. Among numerous semiconductors, the bismuth (Bi)-containing PS has received great attention due to its strong sunlight absorption, facile preparation, and high photostability. Owing to the technology advancement and demerits of the traditional methods, a Bi-containing direct Z-scheme PS has been developed for efficient photogenerated charge carrier separation and strong redox proficiency. In this review, a synthetic Bi-based Z-scheme heterojunction that mimics natural photosynthesis is described, and its design, fabrication methods, and applications are comprehensively reviewed. Specifically, the first section briefly explains the role of various semiconductors in the environmental applications and the importance of the Bi-based materials for constructing the Z-scheme photocatalytic systems. In the successive section, overview of Z-scheme PS are concisely discussed. The fourth and fifth sections extensively explain the degradation of the organic dyes and antibiotics utilizing the Bi-based direct Z-scheme heterojunction. Eventually, the conclusions and future perspectives of this emerging research field are addressed. Overall, this review is potentially useful for the researchers involved in the environmental remediation field as a collection of up-to-date research articles for the fabrication of the Bi-containing direct Z-scheme PS.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of Industrial Environmental Engineering, College of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
32
|
The Loan Trinh K, Ri Chae W, Yoon Lee N. Recent advances in the fabrication strategies of paper-based microfluidic devices for rapid detection of bacteria and viruses. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107548] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
33
|
Dinh VP, Lee NY. Fabrication of a fully integrated paper microdevice for point-of-care testing of infectious disease using Safranin O dye coupled with loop-mediated isothermal amplification. Biosens Bioelectron 2022; 204:114080. [DOI: 10.1016/j.bios.2022.114080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 01/21/2022] [Accepted: 02/03/2022] [Indexed: 11/02/2022]
|
34
|
Trinh KTL, Lee NY. Fabrication of Wearable PDMS Device for Rapid Detection of Nucleic Acids via Recombinase Polymerase Amplification Operated by Human Body Heat. Biosensors (Basel) 2022; 12:bios12020072. [PMID: 35200333 PMCID: PMC8869297 DOI: 10.3390/bios12020072] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 01/18/2022] [Accepted: 01/25/2022] [Indexed: 05/28/2023]
Abstract
Pathogen detection by nucleic acid amplification proved its significance during the current coronavirus disease 2019 (COVID-19) pandemic. The emergence of recombinase polymerase amplification (RPA) has enabled nucleic acid amplification in limited-resource conditions owing to the low operating temperatures around the human body. In this study, we fabricated a wearable RPA microdevice using poly(dimethylsiloxane) (PDMS), which can form soft-but tight-contact with human skin without external support during the body-heat-based reaction process. In particular, the curing agent ratio of PDMS was tuned to improve the flexibility and adhesion of the device for better contact with human skin, as well as to temporally bond the microdevice without requiring further surface modification steps. For PDMS characterization, water contact angle measurements and tests for flexibility, stretchability, bond strength, comfortability, and bendability were conducted to confirm the surface properties of the different mixing ratios of PDMS. By using human body heat, the wearable RPA microdevices were successfully applied to amplify 210 bp from Escherichia coli O157:H7 (E. coli O157:H7) and 203 bp from the DNA plasmid SARS-CoV-2 within 23 min. The limit of detection (LOD) was approximately 500 pg/reaction for genomic DNA template (E. coli O157:H7), and 600 fg/reaction for plasmid DNA template (SARS-CoV-2), based on gel electrophoresis. The wearable RPA microdevice could have a high impact on DNA amplification in instrument-free and resource-limited settings.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Korea;
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Korea
| |
Collapse
|
35
|
Sivakumar R, Lee NY. Adsorptive removal of organic pollutant methylene blue using polysaccharide-based composite hydrogels. Chemosphere 2022; 286:131890. [PMID: 34426282 DOI: 10.1016/j.chemosphere.2021.131890] [Citation(s) in RCA: 35] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 07/28/2021] [Accepted: 08/11/2021] [Indexed: 06/13/2023]
Abstract
Methylene blue (MB) is categorized as an organic dye (OD) released as effluents after various industrial activities and is one of the most abundant pollutants in the aquatic environment. Significantly, because of its potential toxicity, removing MB from wastewater has been a matter of necessity in recent times. Numerous analytical techniques have been applied, among which polysaccharide-based composite hydrogels appear as the most favorable for MB removal because of their large surface area, excellent mechanical properties, swelling capability, and large-scale production. In this review, the first section gives adequate information about the ODs' adverse effects on the environment and the contribution of polysaccharide-based hydrogels for OD removal, especially MB. Next, various mechanisms such as electrostatic interactions, π-π interactions, hydrogen bonding, hydrophobic interaction, van der Waals force, and coordination interaction involved in the adsorption technique are investigated. The third section extensively describes the MB removal by incorporation of various materials such as monomers, metal oxides, magnetic nanoparticles, and clay into the polysaccharide matrix to produce composite hydrogels. Finally, the current limitations and future perspectives of the polysaccharide-based composite hydrogel techniques are addressed. Overall, this review acknowledged the vital role of polysaccharide-based composite hydrogels for MB adsorption by surveying 110 research articles published in the past five years (2015-2021).
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of Industrial Environmental Engineering, College of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
36
|
Trinh KTL, Chae WR, Lee NY. Pressure-Free Assembling of Poly(methyl methacrylate) Microdevices via Microwave-Assisted Solvent Bonding and Its Biomedical Applications. Biosensors (Basel) 2021; 11:bios11120526. [PMID: 34940283 PMCID: PMC8699324 DOI: 10.3390/bios11120526] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/09/2021] [Accepted: 12/16/2021] [Indexed: 06/14/2023]
Abstract
Poly(methyl methacrylate) (PMMA) has become an appealing material for manufacturing microfluidic chips, particularly for biomedical applications, because of its transparency and biocompatibility, making the development of an appropriate bonding strategy critical. In our research, we used acetic acid as a solvent to create a pressure-free assembly of PMMA microdevices. The acetic acid applied between the PMMA slabs was activated by microwave using a household microwave oven to tightly merge the substrates without external pressure such as clamps. The bonding performance was tested and a superior bond strength of 14.95 ± 0.77 MPa was achieved when 70% acetic acid was used. Over a long period, the assembled PMMA device with microchannels did not show any leakage. PMMA microdevices were also built as a serpentine 2D passive micromixer and cell culture platform to demonstrate their applicability. The results demonstrated that the bonding scheme allows for the easy assembly of PMMAs with a low risk of clogging and is highly biocompatible. This method provides for a simple but robust assembly of PMMA microdevices in a short time without requiring expensive instruments.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea;
| | - Woo Ri Chae
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea;
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Korea;
| |
Collapse
|
37
|
Chae DS, Kim ME, Kang KY, Lee NY, Lee WS, Lee JS. Quantitative proteomic analysis comparing grades ICRS1 and ICRS3 in patients with osteoarthritis. Exp Ther Med 2021; 22:1470. [PMID: 34737810 PMCID: PMC8561757 DOI: 10.3892/etm.2021.10905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 09/07/2021] [Indexed: 11/06/2022] Open
Abstract
Osteoarthritis (OA), which is caused by joint damage, is the most common form of arthritis, affecting millions of people worldwide. This damage can accumulate over time, which is why aging is one of the main contributors to joint damage associated with OA. The OA-related proteins that have been reported to date have been identified by the comparative analysis of OA patients with normal controls, following surgical or pharmacological treatment. For the first time, the present study analyzed OA-related proteins in patients with OA according to the International Cartilage Repair Society (ICRS) scale. Changes in protein expression can be observed during the OA process. The present study demonstrated differential protein expression patterns in articular cartilage from ICRS1- and ICRS3-graded OA patients. ICRS grade-matched OA knee samples from 12 OA patients, 6 ICRS grade 1 patients and 6 ICRS3 patients were subjected to proteomic analysis using the LTQ-Orbitrap mass spectrometry system. A total of 231 unique proteins were identified as expressed across the ICRS1 and ICRS3 OA patient groups. Relative differences in protein expression associated with the following classifications were observed: Biological adhesion, cell killing, cellular process, development process and molecular function. Although some of these proteins have been previously reported to be associated with rheumatoid arthritis, including cartilage oligomeric matrix protein, collagen types, angiogenin, complement C5 and CD59 glycoprotein, numerous additional proteins were newly identified, which may further help our understanding of disease pathogenesis. These findings suggested that these proteins may be used to develop novel therapeutic targets for OA.
Collapse
Affiliation(s)
- Dong-Sik Chae
- Department of Orthopedic Surgery, International St. Mary's Hospital, College of Medicine, Catholic Kwandong University, Incheon 22711, Republic of Korea
| | - Mi Eun Kim
- Department of Life Science, Immunology Research Lab, BK21-Four Education Research Group, College of Natural Sciences, Chosun University, Gwangju 61452, Republic of Korea
| | - Kyung-Yil Kang
- Department of Orthopedic Surgery, International St. Mary's Hospital, College of Medicine, Catholic Kwandong University, Incheon 22711, Republic of Korea
| | - Nae Yoon Lee
- Department of Bionano Technology, Gachon University, Seongnam, Gyeonggi-do 13120, Republic of Korea
| | - Woo-Suk Lee
- Department of Orthopedic Surgery, Yonsei University College of Medicine, Gangnam Severence Hospital, Seoul 135720, Republic of Korea
| | - Jun Sik Lee
- Department of Life Science, Immunology Research Lab, BK21-Four Education Research Group, College of Natural Sciences, Chosun University, Gwangju 61452, Republic of Korea
| |
Collapse
|
38
|
Trinh KTL, Le NXT, Lee NY. Microfluidic-based fabrication of alginate microparticles for protein delivery and its application in the in vitro chondrogenesis of mesenchymal stem cells. J Drug Deliv Sci Technol 2021. [DOI: 10.1016/j.jddst.2021.102735] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
39
|
Nguyen HA, Lee NY. Polydopamine aggregation: A novel strategy for power-free readout of loop-mediated isothermal amplification integrated into a paper device for multiplex pathogens detection. Biosens Bioelectron 2021; 189:113353. [PMID: 34049080 DOI: 10.1016/j.bios.2021.113353] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 05/11/2021] [Accepted: 05/13/2021] [Indexed: 12/23/2022]
Abstract
Loop-mediated isothermal amplification (LAMP) has been widely used for detecting pathogens. However, power-free and clear visualization of results still remain challenging. In this study, we developed a paper device integrated with power-free DNA detection strategy realized by polydopamine aggregation. In the presence of DNA amplicons, the polymerization of dopamine into aggregated polydopamine was hindered, while in the absence of DNA amplicons, polydopamine aggregation is facilitated. The porosity of the paper enabled the capillary flow of dispersed polydopamine for positive sample, while aggregated polydopamine remained at the bottom of the paper strip due to large size of the aggregates for negative sample. Based on this mechanism, we fabricated a slidable paper device integrating LAMP with dopamine polymerization for the naked-eye detection, operated in a seamless manner. Moreover, the introduced paper device was successfully used to detect DNA extracted from Escherichia coli O157:H7 and SARS-CoV-2 within 25 min, as well as Enterococcus faecium within 35 min. The detection limits of both Escherichia coli O157:H7 and SARS-CoV-2 were 10-4 ng/μL. The introduced paper device can be used as a simple and sensitive tool for detecting multiple infectious pathogens, making it an ideal tool particularly for resource-limited environment.
Collapse
Affiliation(s)
- Hanh An Nguyen
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
40
|
Kim S, Song J, Kim R, Lee NY, Kim MH, Park HG. Ferrowax microvalves for fully automated serial dilution on centrifugal microfluidic platforms. Biotechnol J 2021; 16:e2100131. [PMID: 34499815 DOI: 10.1002/biot.202100131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 09/06/2021] [Accepted: 09/07/2021] [Indexed: 11/07/2022]
Abstract
We herein describe a centrifugal microfluidic system to accomplish a fully automated serial dilution. The liquid flow on the disc was regulated by utilizing ferrowax microvalves systematically integrated into the channels within specially designed metering structures. By opening the differently positioned microvalves through irradiation of IR laser to allow metering, the same amount of diluent was serially eluted to the dilution chamber from the same diluent chamber. After dilution, the diluted samples were automatically delivered to the respective final product chambers by appropriately opening or closing the microvalves in the connecting channels, followed by rotating the disc. Based on this unique design principle, six consecutive two-fold and 10-fold dilutions were successfully achieved, yielding excellent accuracy in a wide dynamic range up to six orders of magnitude. Very importantly, the overall serial dilution process, including the diluent addition, mixing, and product transfer steps, was completed very rapidly within 5 min, due to the minimized procedures enabled by the automated actuation of the ferrowax microvalves at the rationally designed positions. We expect our centrifugal microfluidic system would serve as a powerful elemental tool to realize fully automated diagnostic microsystems involving the serial dilution process.
Collapse
Affiliation(s)
- Soohyun Kim
- Department of Chemical and Biomolecular Engineering (BK21+ Program), Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Jayeon Song
- Department of Chemical and Biomolecular Engineering (BK21+ Program), Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - RaKyeom Kim
- Department of Chemical and Biomolecular Engineering (BK21+ Program), Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
- Department of BioNano Technology, Gachon University, Gyeonggi-do, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, Gyeonggi-do, Republic of Korea
| | | | - Hyun Gyu Park
- Department of Chemical and Biomolecular Engineering (BK21+ Program), Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| |
Collapse
|
41
|
Abstract
This study introduces a spinning and fully integrated paper-based microdevice that can perform multiple functions, including DNA extraction, amplification, and colorimetric detection, for monitoring two major vancomycin-resistant Enterococci (VREs), which carry the vanA and vanB genes. The spinning microdevice is composed of a stationary part and a spinning part. The square-shaped stationary part has two zones: the lysis and reaction zones. The spinning part, which has a spin wheel-like shape, was inserted perpendicularly into the stationary part so that its two semicircles remained on the upper and lower parts. Sodium hydroxide-treated glass microfiber filter discs, inserted in the upper semicircle, were soaked in the lysis chambers by folding them toward the lysis zone to capture DNA in the lysis chambers. The captured DNA was transferred to the reaction chambers by folding the discs toward the reaction chambers. Water was added to the sodium hydroxide-treated glass microfiber filter discs to elute purified DNA into the reaction chambers. The upper semicircle was then unfolded, and the reaction chambers were sealed for subsequent loop-mediated isothermal amplification (LAMP) for 45 min. After the reaction, the spinning part was spun in the lysis zone direction to bring the lower semicircle, inserted with phenolphthalein-treated glass microfiber filter discs, toward the upper part of the stationary part. By folding it toward the reaction chambers, the lower semicircle came into contact with them and the phenolphthalein-treated glass microfiber filter discs were soaked in the reaction chambers and expressed color after 30 s. Based on the pH change during the LAMP reaction, the phenolphthalein-treated discs remained pink in the absence of target DNA, while those in contact with the positive samples turned colorless. A sensitive detection with a VRE limit of detection of 102 CFU/mL for tap water spiked with VRE carrying the vanA gene was achieved using this microdevice. Both VREs, carrying vanA and vanB genes, were successfully identified from tap water and contaminated equipment surfaces within 75 min. The introduced microdevice demonstrated a rapid, accurate, and sensitive performance for the environmental assessment of VRE contamination in resource-limited regions.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| |
Collapse
|
42
|
Lee NY, Kim NR, Kang JW, Kim G, Han MS, Jang JA, Ahn D, Jeong JH, Han MH, Nam EJ. Increased salivary syndecan-1 level is associated with salivary gland function and inflammation in patients with Sjögren's syndrome. Scand J Rheumatol 2021; 51:220-229. [PMID: 34212822 DOI: 10.1080/03009742.2021.1923162] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Objectives: Syndecan-1 (SDC-1), a transmembrane heparin sulphate proteoglycan predominantly expressed on epithelial cells, also exists in a soluble form through ectodomain shedding. SDC-1 expression and shedding may be modulated in the inflammatory milieu of primary Sjögren's syndrome (SS). We investigated SDC-1 expression in minor salivary glands (MSGs) and analysed the association between salivary or plasma levels of SDC-1 and clinical parameters in SS.Method: We measured salivary and plasma SDC-1 levels via an enzyme-linked immunosorbent assay and assessed the salivary flow rates (SFRs) in 70 patients with SS and 35 healthy subjects. Disease activity indices, serological markers, salivary gland scintigraphy, and MSG biopsy were evaluated in patients with SS.Results: SDC-1 expression was upregulated on ductal epithelial cells in inflamed salivary glands. Salivary SDC-1 levels in patients significantly exceeded those in healthy subjects [median (interquartile range) 49.0 (20.7-79.1) vs 3.7 (1.7-6.3) ng/mL, p < 0.001] and inversely correlated with SFRs (r = -0.358, p = 0.032) and ejection fractions of the parotid (r = -0.363, p = 0.027) and submandibular (r = -0.485, p = 0.002) glands in salivary gland scintigraphy. Plasma SDC-1 levels were significantly correlated with the EULAR Sjögren's Syndrome Disease Activity Index (r = 0.507, p < 0.001) and EULAR Sjögren's Syndrome Patient Reported Index (r = 0.267, p = 0.033). Focus scores were correlated with salivary SDC-1 levels (r = 0.551, p = 0.004).Conclusion: Salivary and plasma SDC-1 levels may constitute potential biomarkers for salivary gland function and disease activity, respectively, in SS.
Collapse
Affiliation(s)
- N Y Lee
- Department of Laboratory Medicine, Kyungpook National University Chilgok Hospital, School of Medicine, Daegu, Republic of Korea
| | - N R Kim
- Division of Rheumatology, Department of Internal Medicine, Kyungpook National University Chilgok Hospital, School of Medicine, Daegu, Republic of Korea
| | - J W Kang
- Division of Rheumatology, Department of Internal Medicine, Daegu Fatima Hospital, Daegu, Republic of Korea
| | - G Kim
- Division of Rheumatology, Department of Internal Medicine, Daegu Fatima Hospital, Daegu, Republic of Korea.,Laboratory for Arthritis and Bone Biology, Fatima Research Institute, Daegu Fatima Hospital, Daegu, Republic of Korea
| | - M-S Han
- Laboratory for Arthritis and Bone Biology, Fatima Research Institute, Daegu Fatima Hospital, Daegu, Republic of Korea
| | - J A Jang
- Laboratory for Arthritis and Bone Biology, Fatima Research Institute, Daegu Fatima Hospital, Daegu, Republic of Korea
| | - D Ahn
- Department of Otolaryngology-Head and Neck Surgery, Kyungpook National University Hospital, School of Medicine, Daegu, Republic of Korea
| | - J H Jeong
- Department of Nuclear Medicine, Kyungpook National University Chilgok Hospital, School of Medicine, Daegu, Republic of Korea
| | - M-H Han
- Department of Pathology, Kyungpook National University Hospital, School of Medicine, Daegu, Republic of Korea
| | - E J Nam
- Division of Rheumatology, Department of Internal Medicine, Kyungpook National University Chilgok Hospital, School of Medicine, Daegu, Republic of Korea
| |
Collapse
|
43
|
Sivakumar R, Lee NY. Recent progress in smartphone-based techniques for food safety and the detection of heavy metal ions in environmental water. Chemosphere 2021; 275:130096. [PMID: 33677270 DOI: 10.1016/j.chemosphere.2021.130096] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 02/10/2021] [Accepted: 02/21/2021] [Indexed: 05/14/2023]
Abstract
Emerging smartphone-based point-of-care tests (POCTs) are cost-effective, precise, and easy to implement in resource-limited areas. Thus, they are considered a potential alternative to conventional diagnostic testing. This review explores food safety and the detection of metal ions in environmental water based on unprecedented smartphone technology. Specifically, we provide an overview of various methods used for target analyte detection (antibiotics, enzymes, mycotoxins, pathogens, pesticides, small molecules, and metal ions), such as colorimetric, fluorescence, microscopic imaging, and electrochemical methods. This paper performs a comprehensive review of smartphone-based POCTs developed in the last three years (2018-2020) and evaluates their relative advantages and limitations. Moreover, we discuss the imperative role of new technology in the progress of POCTs. Sensor materials (metal nanoparticles, carbon dots, quantum dots, organic substrates, etc.) and detection techniques (paper-based, later flow assay, microfluidic platform, etc.) involved in POCTs based on smartphones, and the challenges faced by these techniques, are addressed.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of Industrial Environmental Engineering, College of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
44
|
Nam EJ, Ham JY, Song KE, Kim YK, Lee NY. Incidence and Distribution of the Pathogens Causing Central Nervous System Infections at the University Hospital of Korea. Clin Lab 2021; 67. [PMID: 34107628 DOI: 10.7754/clin.lab.2020.201118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND The pathogens involved in central nervous system (CNS) infections are various, such as viruses, bacteria, and fungi, so a syndromic approach can be required. In addition, since their rapid and accurate detection is very crucial, molecular diagnostics using cerebrospinal fluid is becoming the emerging standard method. METHODS The study was conducted retrospectively to identify the incidence and distribution patterns of the pathogens according to gender, age, season, and month and to analyze their codetection from August 2017 to July 2020. It was also conducted to investigate turn-around times (TATs) according to the detection method. The detection methods were FilmArray® Meningitis/Encephalitis (M/E) method (FilmArray), Cepheid® Xpert EV assay (Xpert), and Multiplex PCR method for five species of bacteria. RESULTS The overall incidence for at least one pathogen was 13.9% (346/2,496). The highest incidence was shown in age group 4 (3 - 6 years), with 27.4%. The detection rates by FilmArray, Xpert, and Multiplex PCR method were 39.8%, 41.7%, and 0.4%, respectively. Enterovirus (EV) showed the highest incidence rate, which accounted for 37.0%. The distribution of the pathogens according to the age groups were the highest in age group 4, with 47.5% (168/354), followed by 27.4% (97/354) in age group 5. Of the ten cases in which bacteria were detected, S. agalactiae accounted for 60.0% (6/10), most of which occurred in age group 1. E. coli K1, L. monocytogenes, and N. meningitidis were not detected. In the viral distribution, EV accounted for the highest proportion in all age groups. The overall proportion of EV accounted for 87.6% (310/354), followed by human parechovirus with 2.8% (10/354). The most commonly detected season was summer, comprising 75.1%. A total of eight cases of co-detection with two pathogens accounted for 1.6% (8/507) in FilmArray. In FilmArray, all TATs were found to be shorter than Xpert. CONCLUSIONS The information on the incidence and distribution patterns of the pathogens causing CNS infections and their rapid detection are critically important to clinicians in the management of immunocompromised patients, elderly, and children. The expeditious molecular diagnostics for these pathogens would be valuable in medical decisions by clinicians.
Collapse
|
45
|
Thi Huong V, Thi Ta HK, Mai NXD, Van Tran TT, Khuyen BX, Trinh KTL, Lee NY, Phan BT, Tran NHT. Development of a highly sensitive sensor chip using optical diagnostic based on functionalized plasmonically active AuNPs. Nanotechnology 2021; 32:335505. [PMID: 33979787 DOI: 10.1088/1361-6528/ac0080] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 05/12/2021] [Indexed: 06/12/2023]
Abstract
Measuring solution concentration plays an important role in chemical, biochemical, clinical diagnosis, environmental monitoring, and biological analyses. In this work, we develop a transmission-mode localized surface plasmon resonance sensor chip system and convenient method which is highly efficient, highly sensitive for detection sensing using multimode fiber. The plasmonically active sensor's surface AuNPs with high-density NPs were decorated onto 1 cm sensing length of various clad-free fiber in the form of homogeneous monolayer utilizing a self-assembly process for immobilization of the target molecule. The carboxyl bond is formed through a functional reaction on the sensor head. Using the significance in the refractive index difference and numerical aperture, which is caused by a variation in the concentration of measuring bovine serum albumin (BSA) protein which can be accurately measured by the output signal. The refractive index variation of the medium analyte layer can be converted to signal output power change at the He-Ne wavelength of 632.8 nm. The sensor detection limit was estimated to be 0.075 ng ml-1for BSA protein which shows high sensitivity compared to other types of label-free optical biosensors. This also leads to a possibility of finding the improvement in the sensitivity label-free biosensors. The conventional method should allow multimode fiber biosensors to become a possible replacement for conventional biosensing techniques based on fluorescence.
Collapse
Affiliation(s)
- Vu Thi Huong
- Faculty Department of Information Communication, Convergence Technology, Soongsil University, Seoul 06978, Republic of Korea
| | - Hanh Kieu Thi Ta
- Faculty of Materials Science and Technology, University of Science, HoChiMinh City, Vietnam
- Vietnam National University, HoChiMinh City, Vietnam
- Center for Innovative Materials and Architectures (INOMAR), HoChiMinh City, Vietnam
| | - Ngoc Xuan Dat Mai
- Vietnam National University, HoChiMinh City, Vietnam
- Center for Innovative Materials and Architectures (INOMAR), HoChiMinh City, Vietnam
| | - Thi Thanh Van Tran
- Faculty of Materials Science and Technology, University of Science, HoChiMinh City, Vietnam
- Vietnam National University, HoChiMinh City, Vietnam
| | - Bui Xuan Khuyen
- Institute of Materials Science, Vietnam Academy of Science and Technology, Hanoi, Vietnam
| | - Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, College of Industrial Environmental Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Bach Thang Phan
- Vietnam National University, HoChiMinh City, Vietnam
- Center for Innovative Materials and Architectures (INOMAR), HoChiMinh City, Vietnam
- Laboratory of Advanced Materials, University of Science, HoChiMinh City, Vietnam
| | - Nhu Hoa Thi Tran
- Faculty of Materials Science and Technology, University of Science, HoChiMinh City, Vietnam
- Vietnam National University, HoChiMinh City, Vietnam
| |
Collapse
|
46
|
Sivakumar R, Lee NY. Paper-Based Fluorescence Chemosensors for Metal Ion Detection in Biological and Environmental Samples. BioChip J 2021. [DOI: 10.1007/s13206-021-00026-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
47
|
Abstract
Because of the global spread of antimicrobials, there is an urgent need to develop rapid and effective tools for antimicrobial susceptibility testing to help clinicians prescribe accurate and appropriate antibiotic doses sooner. The conventional methods for antimicrobial susceptibility testing are usually based on bacterial culture methods, which are time-consuming, complicated, and labor-intensive. Therefore, other approaches are needed to address these issues. Recently, microfluidic technology has gained significant attention in infection management due to its advantages including rapid detection, high sensitivity and specificity, highly automated assay, simplicity, low cost, and potential for point-of-care testing in low-resource areas. Microfluidic advances for antimicrobial susceptibility testing can be classified into phenotypic (usually culture-based) and genotypic tests. Genotypic antimicrobial susceptibility testing is the detection of resistant genes in a microorganism using methods such as nucleic acid amplification. This review (with 107 references) surveys the different forms of nucleic acid amplification-based microdevices used for genotypic antimicrobial susceptibility testing. The first section reviews the serious threat of antimicrobial-resistant microorganisms and the urgent need for fast check-ups. Next, several conventional antimicrobial susceptibility testing methods are discussed, and microfluidic technology as a promising candidate for rapid detection of antimicrobial-resistant microorganisms is briefly introduced. The next section highlights several advancements of microdevices, with an emphasis on their working principles and performance. The review concludes with the importance of fully integrated microdevices and a discussion on future perspectives.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea.
| |
Collapse
|
48
|
Thai DA, Lee NY. A paper-based colorimetric chemosensor for rapid and highly sensitive detection of sulfide for environmental monitoring. Anal Methods 2021; 13:1332-1339. [PMID: 33651059 DOI: 10.1039/d1ay00074h] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
In this study, we report on paper-based colorimetric detection of sulfide using a newly synthesized chemical acting as a chemosensor, based on the deprotonation mechanism. Paper strips were also fabricated and incorporated with the chemosensor for on-site monitoring. The presence of sulfide induced deprotonation of a hydroxyl group of the chemosensor, which eventually resulted in a distinct spectral change in the tube as well as a visible color change on a paper strip. The chemosensor showed a highly selective colorimetric response to sulfide by changing its color from colorless to yellow without any interference from a mixture containing other anions. Moreover, the chemosensor effectively differentiated sulfide from other thiols, including cysteine and glutathione. The chemosensor colorimetrically detected sulfide with a fast response time of 10 s under physiological conditions. Practically, the paper test strip enabled colorimetric visualization of as low as 30 μM sulfide and a good recovery in quantitative analysis in water samples. The introduced paper-based chemosensor is a promising colorimetric strategy with rapid, selective, and sensitive sensing abilities for sulfide monitoring in environmental water samples.
Collapse
Affiliation(s)
- Duc Anh Thai
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea.
| | | |
Collapse
|
49
|
Le NXT, Trinh KTL, Lee NY. Poly(acrylic acid) as an adhesion promoter for UV-assisted thermoplastic bonding: Application for the in vitro construction of human blood vessels. Mater Sci Eng C Mater Biol Appl 2021; 122:111874. [PMID: 33641892 DOI: 10.1016/j.msec.2021.111874] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 12/27/2020] [Accepted: 01/06/2021] [Indexed: 11/25/2022]
Abstract
In this study, we introduced a novel adhesion bonding method for fabricating thermoplastic microdevices using poly(acrylic acid) (PAA) as a UV-assisted adhesion promoter. The bonding mechanism was based on the covalent cross-links between poly(methyl methacrylate) (PMMA) and PAA via the free radicals in their carbon backbone generated under UV irradiation. The water contact angle and Fourier-transformed infrared (FTIR) analysis were performed to analyze the surface characteristics of the PAA-coated PMMA. PMMAs were bonded under UV treatment for 60 s with the highest bond strength of around 1.18 MPa. The PMMA microdevice was leak-proof for over 200 h. Besides, clog-free PMMA microdevices with various-sizes microchannels were performed to demonstrate such a high applicable bonding method for microdevice fabrication. Moreover, PMMAs were bonded with other thermoplastics with a bond strength of around 0.5 MPa. Notably, collagen was easily coated inside the PMMA microchannels via electrostatic interaction between PAA and collagen which is beneficial for on-device cell culture. As a result, a layered co-culture model of smooth muscle cells (SMCs) and human umbilical vein endothelial cells (HUVECs) was realized inside simple straight microchannels mimicking human blood vessel wall. Therefore, the introduced bonding method could pave the way for fabricating microdevice for cell-related applications.
Collapse
Affiliation(s)
- Nguyen Xuan Thanh Le
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Kieu The Loan Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Republic of Korea.
| |
Collapse
|
50
|
Sivakumar R, Dinh VP, Lee NY. Ultraviolet-induced in situ gold nanoparticles for point-of-care testing of infectious diseases in loop-mediated isothermal amplification. Lab Chip 2021; 21:700-709. [PMID: 33554994 DOI: 10.1039/d1lc00019e] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The present study investigated ultraviolet-induced in situ gold nanoparticles (AuNPs) coupled with loop-mediated isothermal amplification (LAMP) for the point-of-care testing (POCT) of two major infectious pathogens, namely, Coronavirus (COVID-19) and Enterococcus faecium (E. faecium spp.). In the process, gold ions in a gold chloride (HAuCl4) solution were reduced using trisodium citrate (Na3Ct), a reducing agent, and upon UV illumination, red-colored AuNPs were produced in the presence of LAMP amplicons. The nitrogenous bases of the target deoxyribonucleic acid (DNA) acted as a physical support for capturing gold ions dissolved in the sample. The high affinity of gold with the nitrogenous bases enabled facile detection within 10 min, and the detection limit of COVID-19 plasmid DNA was as low as 42 fg μL-1. To ensure POCT, we designed a portable device that contained arrays of reagent chambers and detection chambers. In the portable device, colorimetric reagents such as HAuCl4 and Na3Ct were contained in the reagent chambers; these reagents were subsequently transferred to the detection chambers where LAMP amplicons were present and thus allowed convenient sample delivery and multiplex detection. Owing to the high sensitivity of the in situ AuNPs, simplicity of portable device fabrication, and rapid colorimetric detection, we strongly believe that the fabricated portable device could serve as a kit for rapid POCT for instantaneous detection of infectious diseases, and could be readily usable at the bedside.
Collapse
Affiliation(s)
- Rajamanickam Sivakumar
- Department of Industrial Environmental Engineering, College of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | - Vu Phong Dinh
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea.
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea.
| |
Collapse
|