1
|
Rhouati A, Zourob M. Development of a Multiplexed Electrochemical Aptasensor for the Detection of Cyanotoxins. BIOSENSORS 2024; 14:268. [PMID: 38920572 PMCID: PMC11202177 DOI: 10.3390/bios14060268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 05/12/2024] [Accepted: 05/14/2024] [Indexed: 06/27/2024]
Abstract
In this study, we report a multiplexed platform for the simultaneous determination of five marine toxins. The proposed biosensor is based on a disposable electrical printed (DEP) microarray composed of eight individually addressable carbon electrodes. The electrodeposition of gold nanoparticles on the carbon surface offers high conductivity and enlarges the electroactive area. The immobilization of thiolated aptamers on the AuNP-decorated carbon electrodes provides a stable, well-orientated and organized binary self-assembled monolayer for sensitive and accurate detection. A simple electrochemical multiplexed aptasensor based on AuNPs was designed to synchronously detect multiple cyanotoxins, namely, microcystin-LR (MC-LR), Cylindrospermopsin (CYL), anatoxin-α, saxitoxin and okadaic acid (OA). The choice of the five toxins was based on their widespread presence and toxicity to aquatic ecosystems and humans. Taking advantage of the conformational change of the aptamers upon target binding, cyanotoxin detection was achieved by monitoring the resulting electron transfer increase by square-wave voltammetry. Under the optimal conditions, the linear range of the proposed aptasensor was estimated to be from 0.018 nM to 200 nM for all the toxins, except for MC-LR where detection was possible within the range of 0.073 to 150 nM. Excellent sensitivity was achieved with the limits of detection of 0.0033, 0.0045, 0.0034, 0.0053 and 0.0048 nM for MC-LR, CYL, anatoxin-α, saxitoxin and OA, respectively. Selectivity studies were performed to show the absence of cross-reactivity between the five analytes. Finally, the application of the multiplexed aptasensor to tap water samples revealed very good agreement with the calibration curves obtained in buffer. This simple and accurate multiplexed platform could open the window for the simultaneous detection of multiple pollutants in different matrices.
Collapse
Affiliation(s)
- Amina Rhouati
- Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia;
- Bioengineering Laboratory, Higher National School of Biotechnology, Constantine 25100, Algeria
| | - Mohammed Zourob
- Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia;
| |
Collapse
|
2
|
Bai X, Gong W, Guo Y, Zhu D, Li X. Detection of saxitoxin by a SERS aptamer sensor based on enzyme cycle amplification technology. Analyst 2023; 148:2327-2334. [PMID: 37097282 DOI: 10.1039/d3an00330b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023]
Abstract
Saxitoxin (STX) is a typical toxic guanidinium neurotoxin, one of the paralytic shellfish poisons (PSP), which poses a serious threat to human health. In this paper, a simple and sensitive SERS aptamer sensor (abbreviated as AuNP@4-NTP@SiO2) for the quantitative determination of STX was developed. Hairpin aptamers of saxitoxin are modified on magnetic beads and used as recognition elements. In the presence of STX, DNA ligase, and the rolling circle template (T1), a rolling circle amplification reaction was triggered to produce long single-stranded DNA containing repetitive sequences. The sequence can be hybridized with the SERS probe to realize the rapid detection of STX. Due to the inherent merits of its components, the obtained AuNP@4-NTP@SiO2 SERS aptamer sensor manifests excellent sensing performance for STX detection with a wide linear range from 2.0 × 10-10 mol L-1 to 5.0 × 10-4 mol L-1 and a lower detection limit of 1.2 × 10-11 mol L-1. This SERS sensor can provide a strategy for the micro-detection of other biological toxins by changing the aptamer sequence.
Collapse
Affiliation(s)
- Xinna Bai
- Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Chemistry and Chemical Engineering, Linyi University, Linyi, Shandong 276005, China.
| | - Weifang Gong
- Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Chemistry and Chemical Engineering, Linyi University, Linyi, Shandong 276005, China.
| | - Yaxin Guo
- Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Chemistry and Chemical Engineering, Linyi University, Linyi, Shandong 276005, China.
| | - Di Zhu
- Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Chemistry and Chemical Engineering, Linyi University, Linyi, Shandong 276005, China.
| | - Xuemei Li
- Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Chemistry and Chemical Engineering, Linyi University, Linyi, Shandong 276005, China.
| |
Collapse
|
3
|
Wei LN, Luo L, Wang BZ, Lei HT, Guan T, Shen YD, Wang H, Xu ZL. Biosensors for detection of paralytic shellfish toxins: Recognition elements and transduction technologies. Trends Food Sci Technol 2023. [DOI: 10.1016/j.tifs.2023.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
4
|
Chakraborty P, Krishnani KK. Emerging bioanalytical sensors for rapid and close-to-real-time detection of priority abiotic and biotic stressors in aquaculture and culture-based fisheries. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 838:156128. [PMID: 35605873 DOI: 10.1016/j.scitotenv.2022.156128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 05/12/2022] [Accepted: 05/17/2022] [Indexed: 06/15/2023]
Abstract
Abiotic stresses of various chemical contamination of physical, inorganic, organic and biotoxin origin and biotic stresses of bacterial, viral, parasitic and fungal origins are the significant constraints in achieving higher aquaculture production. Testing and rapid detection of these chemical and microbial contaminants are crucial in identifying and mitigating abiotic and biotic stresses, which has become one of the most challenging aspects in aquaculture and culture-based fisheries. The classical analytical techniques, including titrimetric methods, spectrophotometric, mass spectrometric, spectroscopic, and chromatographic techniques, are tedious and sometimes inaccessible when required. The development of novel and improved bioanalytical methods for rapid, selective and sensitive detection is a wide and dynamic field of research. Biosensors offer precise detection of biotic and abiotic stressors in aquaculture and culture-based fisheries within no time. This review article allows filling the knowledge gap for detection and monitoring of chemical and microbial contaminants of abiotic and biotic origin in aquaculture and culture-based fisheries using nano(bio-) analytical technologies, including nano(bio-)molecular and nano(bio-)sensing techniques.
Collapse
Affiliation(s)
- Puja Chakraborty
- ICAR-Central Institute of Fisheries Education, Panch Marg, Off Yari Road, Versova, Andheri (W), Mumbai 400061, India
| | - K K Krishnani
- ICAR-Central Institute of Fisheries Education, Panch Marg, Off Yari Road, Versova, Andheri (W), Mumbai 400061, India.
| |
Collapse
|
5
|
Kumar S, Sharma R, Bhawna, Gupta A, Singh P, Kalia S, Thakur P, Kumar V. Prospects of Biosensors Based on Functionalized and Nanostructured Solitary Materials: Detection of Viral Infections and Other Risks. ACS OMEGA 2022; 7:22073-22088. [PMID: 35811879 PMCID: PMC9260923 DOI: 10.1021/acsomega.2c01033] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 05/16/2022] [Indexed: 10/04/2023]
Abstract
Advances in nanotechnology over the past decade have emerged as a substitute for conventional therapies and have facilitated the development of economically viable biosensors. Next-generation biosensors can play a significant role in curbing the spread of various viruses, including HCoV-2, and controlling morbidity and mortality. Pertaining to the impact of the current pandemic, there is a need for point-of-care biosensor-based testing as a detection method to accelerate the detection process. Integrating biosensors with nanostructures could be a substitute for ultrasensitive label-free biosensors to amplify sensing and miniaturization. Notably, next-generation biosensors could expedite the detection process. An elaborate description of various types of functionalized nanomaterials and their synthetic aspects is presented. The utility of the functionalized nanostructured materials for fabricating nanobiosensors to detect several types of viral infections is described in this review. This review also discusses the choice of appropriate nanomaterials, as well as challenges and opportunities in the field of nanobiosensors.
Collapse
Affiliation(s)
- Sanjeev Kumar
- Department
of Chemistry, University of Delhi, New Delhi, Delhi 110007, India
- Department
of Chemistry, Kirori Mal College, University
of Delhi, New Delhi, Delhi 110007, India
| | - Ritika Sharma
- Department
of Biochemistry, University of Delhi, New Delhi, Delhi 110021, India
| | - Bhawna
- Department
of Chemistry, University of Delhi, New Delhi, Delhi 110007, India
| | - Akanksha Gupta
- Department
of Chemistry, Sri Venkateswara College, University of Delhi, New Delhi, Delhi 110021, India
| | - Prashant Singh
- Department
of Chemistry, Atma Ram Sanatan Dharma College, University of Delhi, New Delhi, Delhi 110021, India
| | - Susheel Kalia
- Department
of Chemistry, Indian Military Academy, Dehradun, Uttarakhand 248007, India
| | - Pankaj Thakur
- Special
Centre for Nanoscience, Jawaharlal Nehru
University, New Delhi, Delhi 110067, India
| | - Vinod Kumar
- Special
Centre for Nanoscience, Jawaharlal Nehru
University, New Delhi, Delhi 110067, India
| |
Collapse
|
6
|
Label-Free Detection of Saxitoxin with Field-Effect Device-Based Biosensor. NANOMATERIALS 2022; 12:nano12091505. [PMID: 35564214 PMCID: PMC9102806 DOI: 10.3390/nano12091505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 04/23/2022] [Accepted: 04/26/2022] [Indexed: 11/16/2022]
Abstract
Saxitoxin (STX) is a highly toxic and widely distributed paralytic shellfish toxin (PSP), posing a serious hazard to the environment and human health. Thus, it is highly required to develop new STX detection approaches that are convenient, desirable, and affordable. This study presented a label-free electrolyte-insulator-semiconductor (EIS) sensor covered with a layer-by-layer developed positively charged Poly (amidoamine) (PAMAM) dendrimer. An aptamer (Apt), which is sensitive to STX was electrostatically immobilized onto the PAMAM dendrimer layer. This results in an Apt that is preferably flat inside a Debye length, resulting in less charge-screening effect and a higher sensor signal. Capacitance-voltage and constant-capacitance measurements were utilized to monitor each step of a sensor surface variation, namely, the immobilization of PAMAM dendrimers, Apt, and STX. Additionally, the surface morphology of PAMAM dendrimer layers was studied by using atomic force microscopy and scanning electron microscopy. Fluorescence microscopy was utilized to confirm that Apt was successfully immobilized on a PAMAM dendrimer-modified EIS sensor. The results presented an aptasensor with a detection range of 0.5–100 nM for STX detection and a limit of detection was 0.09 nM. Additionally, the aptasensor demonstrated high selectivity and 9-day stability. The extraction of mussel tissue indicated that an aptasensor may be applied to the detection of STX in real samples. An aptasensor enables marine toxin detection in a rapid and label-free manner.
Collapse
|
7
|
Noureen B, Ullah N, Tian Y, Du L, Chen W, Wu C, Wang P. An electrochemical PAH-modified aptasensor for the label-free and highly-sensitive detection of saxitoxin. Talanta 2022; 240:123185. [PMID: 34973551 DOI: 10.1016/j.talanta.2021.123185] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/22/2021] [Accepted: 12/26/2021] [Indexed: 01/19/2023]
Abstract
Saxitoxin (STX), is one of the most dangerous and widespread paralytic shellfish toxins, causing a severe threat to the ecosystem and human health. So, it is important and highly essential to develop novel techniques for STX detection in a convenient, desirable, and low-cost manner. Herein, this study developed an electrolyte-insulator-semiconductor (EIS) sensor covered with a layer-by-layer prepared, positively-charged weak polyelectrolyte layer of poly (allylamine hydrochloride) (PAH) for the label-free detection of STX. The specific aptamer (Apt) sensitive to STX was electrostatically adsorbed onto the PAH layer. This leads to a preferentially flat orientation of the Apt within the Debye length, thus yielding a reduced charge-screening influence and a higher sensor signal. Each step of sensor surface modification, i.e. PAH adsorption, immobilization of Apt, and attachment of STX, was monitored by capacitance-voltage (C-V) and constant-capacitance (ConCap) measurements. Furthermore, atomic force microscopy (AFM) was employed to characterize the surface morphology and roughness of the PAH layer. Fluorescence microscopy was used to confirm the effective immobilization of Apt onto the PAH-modified EIS sensor. The results showed that the detection range of this aptasensor for STX detection was 0.5-100 nM and the detection limit was as low as 0.05 nM. Furthermore, this aptasensor showed good selectivity and 9 days' stability. The mussel tissue extraction test suggested that this aptasensor can be used to detect STX in real samples. This aptasensor provides a convenient approach for moderate, rapid, and label-free detection of marine biological toxins.
Collapse
Affiliation(s)
- Beenish Noureen
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Science, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, 710061, China
| | - Najeeb Ullah
- Department of Biochemistry and Molecular Biology, School of Basic Medical Sciences, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, 710061, China
| | - Yulan Tian
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Science, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, 710061, China
| | - Liping Du
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Science, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, 710061, China; Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
| | - Wei Chen
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Science, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, 710061, China
| | - Chunsheng Wu
- Institute of Medical Engineering, Department of Biophysics, School of Basic Medical Science, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, 710061, China.
| | - Ping Wang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
| |
Collapse
|
8
|
3D Impedimetric Biosensor for Cyanobacteria Detection in Natural Water Sources. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors10010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The excessive growth of cyanobacteria in freshwater sources produces the development of toxic blooms mainly due to the production of cyanotoxins. Here, a novel impedimetric biosensor based on a three-dimensional interdigitated electrode array (3D-IDEA) for detection of cyanobacteria cells is reported. The 3D-IDEA sensor surface biofunctionalization was performed by means of the layer-by-layer method using polyethyleneimine (PEI) as the anchoring layer and concanavalin A (Con A) as the bioreceptor to lipopolysaccharides of cyanobacteria cells. The developed PEI-Con A 3D-IDEA sensors show a linear response (R2 = 0.992) of the impedance changes (RS) versus the logarithm of cyanobacteria concentrations in the range of 102–105 cells·mL−1 with the detection limit of 100 cells·mL−1. Moreover, to prevent the interference from components that may be present in real water samples and minimize a possible sample matrix effect, a filtration methodology to recover cyanobacterial cells was developed. The proposed methodology allows 91.2% bacteria recovery, permitting to obtain results similar to controlled assays. The developed system can be used in aquatic environments to detect cyanobacteria and consequently to prevent the formation of blooms and the production of cyanotoxins. Con A can bind to most polysaccharides and so react with other types of bacteria. However, currently, on the market, it is not possible to find specific biorecognition elements for cyanobacteria. Taking into consideration the specificity of samples to be analyzed (natural water resources), it is difficult to expect high concentration of other bacteria. In this sense, the developed methodology may be used as an alarm system to select samples for more thorough and precise laboratory analysis.
Collapse
|
9
|
Chung S, Bode L, Hall DA. Point-of-care human milk testing for maternal secretor status. Anal Bioanal Chem 2021; 414:3187-3196. [PMID: 34741182 PMCID: PMC8956550 DOI: 10.1007/s00216-021-03697-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 09/21/2021] [Accepted: 09/24/2021] [Indexed: 11/27/2022]
Abstract
We present an electrochemical impedimetric-based biosensor for monitoring the variation in human milk oligosaccharide (HMO) composition. 2′-Fucosyllactose (2’FL) is an HMO associated with infant growth, cognitive development, and protection from infectious diarrhea, one of the major causes of infant death worldwide. Due to genetic variation, the milk of some women (non-secretors) contains no or very little 2′FL with potential implications for infant health and development. However, there is currently no technology to analyze the presence and concentration of HMOs in human milk at the point-of-care (POC). The lack of such technology represents a major impediment to advancing human milk research and improving maternal-infant health. Towards this unmet need, we report an impedimetric assay for HMOs with an α-1,2 linkage, the most abundant of which is 2′FL. The sensor uses a lectin for affinity, specifically Ulex europaeusagglutininI (UEA), with electrochemical readout. In spiked studies, the sensor exhibited a high degree of linearity (R2 = 0.991) over 0.5 to 3.0 μM with a 330-nM detection limit. The sensor performance was clinically validated using banked human milk samples and correctly identified all secretor vs. non-secretor samples. Furthermore, despite the short 35-min assay time and low sample volume (25 μL), the assay was highly correlated with HPLC measurements. This bedside human milk testing assay enables POC, “sample-to-answer” quantitative HMO measurement, and will be a valuable tool to assess milk composition.
Collapse
Affiliation(s)
- Saeromi Chung
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Lars Bode
- Department of Pediatrics, University of California San Diego, La Jolla, CA, 92093, USA
- Mother-Milk-Infant Center of Research Excellence (MOMI CORE), University of California San Diego, La Jolla, CA, 92093, USA
| | - Drew A Hall
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, 92093, USA.
- Department of Bioengineering, University of California San Diego, La Jolla, CA, 92093, USA.
| |
Collapse
|
10
|
Electrochemical Biosensors for Tracing Cyanotoxins in Food and Environmental Matrices. BIOSENSORS-BASEL 2021; 11:bios11090315. [PMID: 34562905 PMCID: PMC8468299 DOI: 10.3390/bios11090315] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 08/30/2021] [Accepted: 09/01/2021] [Indexed: 12/13/2022]
Abstract
The adoption of electrochemical principles to realize on-field analytical tools for detecting pollutants represents a great possibility for food safety and environmental applications. With respect to the existing transduction mechanisms, i.e., colorimetric, fluorescence, piezoelectric etc., electrochemical mechanisms offer the tremendous advantage of being easily miniaturized, connected with low cost (commercially available) readers and unaffected by the color/turbidity of real matrices. In particular, their versatility represents a powerful approach for detecting traces of emerging pollutants such as cyanotoxins. The combination of electrochemical platforms with nanomaterials, synthetic receptors and microfabrication makes electroanalysis a strong starting point towards decentralized monitoring of toxins in diverse matrices. This review gives an overview of the electrochemical biosensors that have been developed to detect four common cyanotoxins, namely microcystin-LR, anatoxin-a, saxitoxin and cylindrospermopsin. The manuscript provides the readers a quick guide to understand the main electrochemical platforms that have been realized so far, and the presence of a comprehensive table provides a perspective at a glance.
Collapse
|