1
|
Kontogiannis T, Braybrook J, McElroy C, Foy C, Whale AS, Quaglia M, Smales CM. Characterization of AAV vectors: A review of analytical techniques and critical quality attributes. Mol Ther Methods Clin Dev 2024; 32:101309. [PMID: 39234444 PMCID: PMC11372808 DOI: 10.1016/j.omtm.2024.101309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/06/2024]
Abstract
Standardized evaluation of adeno-associated virus (AAV) vector products for biotherapeutic application is essential to ensure the safety and efficacy of gene therapies. This includes analyzing the critical quality attributes of the product. However, many of the current analytical techniques used to assess these attributes have limitations, including low throughput, large sample requirements, poorly understood measurement variability, and lack of comparability between methods. To address these challenges, it is essential to establish higher-order reference methods that can be used for comparability measurements, optimization of current assays, and development of reference materials. Highly precise methods are necessary for measuring the empty/partial/full capsid ratios and the titer of AAV vectors. Additionally, it is important to develop methods for the measurement of less-established critical quality attributes, including post-translational modifications, capsid stoichiometry, and methylation profiles. By doing so, we can gain a better understanding of the influence of these attributes on the quality of the product. Moreover, quantification of impurities, such as host-cell proteins and DNA contaminants, is crucial for obtaining regulatory approval. The development and application of refined methodologies will be essential to thoroughly characterize AAV vectors by informing process development and facilitating the generation of reference materials for assay validation and calibration.
Collapse
Affiliation(s)
- Theodoros Kontogiannis
- School of Biosciences, Division of Natural Sciences, University of Kent, Canterbury, Kent CT2 7NJ, UK
- National Measurement Laboratory at LGC, Teddington, Middlesex TW11 0LY, UK
| | - Julian Braybrook
- National Measurement Laboratory at LGC, Teddington, Middlesex TW11 0LY, UK
| | | | - Carole Foy
- National Measurement Laboratory at LGC, Teddington, Middlesex TW11 0LY, UK
| | - Alexandra S Whale
- National Measurement Laboratory at LGC, Teddington, Middlesex TW11 0LY, UK
| | - Milena Quaglia
- Reading Scientific Services Ltd, Reading Science Centre, Whiteknights Campus, Pepper Lane, Reading Berkshire RG6 6LA, UK
| | - C Mark Smales
- School of Biosciences, Division of Natural Sciences, University of Kent, Canterbury, Kent CT2 7NJ, UK
- National Institute for Bioprocessing Research and Training, Blackrock, Co, Foster Avenue, A94 X099 Mount Merrion, Dublin, Ireland
| |
Collapse
|
2
|
Crego-Vicente B, Febrer-Sendra B, Nindia A, Pessela A, Aixut S, Martínez-Campreciós J, Mediavilla A, Silgado A, Sulleiro E, Treviño B, Molina I, Muro A, Salvador F, Fernández-Soto P. First field study using Strong-LAMP for diagnosis of strongyloidiasis in Cubal, Angola. Parasit Vectors 2023; 16:393. [PMID: 37907997 PMCID: PMC10619288 DOI: 10.1186/s13071-023-06009-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 10/10/2023] [Indexed: 11/02/2023] Open
Abstract
BACKGROUND Strongyloides stercoralis infection is a common neglected tropical disease distributed worldwide, mainly in tropical and subtropical climates. The impact of S. stercoralis infections on human health ranges from mild asymptomatic infections to chronic strongyloidiasis unnoticeable until the host is immunosuppressed. In severe strongyloidiasis, a syndrome of hyperinfection and larval dissemination to various organs can occur with high mortality rates. The diagnosis of strongyloidiasis is challenging because of the absence of a single standard reference test with high sensitivity and specificity, which also makes it difficult to estimate the accuracy of other diagnostic tests. This study aimed to evaluate, for the first time, the use of an easy-to-perform loop-mediated isothermal amplification (LAMP) colorimetric assay (named Strong-LAMP) for the molecular screening of strongyloidiasis in stool samples from patients in a low-resource endemic area in Cubal, Angola. To compare different LAMP application scenarios, the performance of the Strong-LAMP under field conditions in Angola was reassessed in a well-equipped reference laboratory in Spain and compared with a quantitative polymerase chain reaction (qPCR) method. METHODS A total of 192 stool samples were collected from adult population in Cubal, Angola, and examined by parasitological methods (direct saline microscopy and Baermann's technique). DNA was extracted from each stool sample using a commercial kit and tested by the colorimetric Strong-LAMP assay for the detection of Strongyloides spp. under field conditions. Furthermore, all samples were shipped to a well-equipped laboratory in Spain, reanalysed by the same procedure and compared with a qPCR method. The overall results after testing were compared. RESULTS Strongyloides stercoralis larvae were identified by direct saline microscopy and Baermann in a total of 10/192 (5.2%) and 18/192 (9.4%) stool samples, respectively. Other helminth and protozoan species were also identified. The Strong-LAMP-positive results were visually detected in 69/192 (35.9%) stool samples. The comparison of Strong-LAMP results in field conditions and at a reference laboratory matched in a total of 146/192 (76.0%) samples. A total of 24/192 (12.5%) stool samples tested positive by qPCR. CONCLUSIONS This is the first study in which colorimetric Strong-LAMP has been clinically evaluated in a resource-poor strongyloidiasis endemic area. Strong-LAMP has been shown to be more effective in screening for strongyloidiasis than parasitological methods under field conditions and qPCR in the laboratory. Our Strong-LAMP has proven to be a field-friendly and highly accurate molecular test for the diagnosis of strongyloidiasis.
Collapse
Affiliation(s)
- Beatriz Crego-Vicente
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, Salamanca, Spain
| | - Begoña Febrer-Sendra
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, Salamanca, Spain
| | | | | | | | - Joan Martínez-Campreciós
- Hospital Nossa Senhora da Paz, Cubal, Angola
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | - Alejandro Mediavilla
- Microbiology Department, Vall d'Hebron University Hospital, PROSICS, Barcelona, Spain
| | - Aroa Silgado
- Microbiology Department, Vall d'Hebron University Hospital, PROSICS, Barcelona, Spain
| | - Elena Sulleiro
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
- Microbiology Department, Vall d'Hebron University Hospital, PROSICS, Barcelona, Spain
| | - Begoña Treviño
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
- International Health Unit Vall d'Hebron-Drassanes, Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS, Barcelona, Spain
| | - Israel Molina
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
- International Health Unit Vall d'Hebron-Drassanes, Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS, Barcelona, Spain
| | - Antonio Muro
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, Salamanca, Spain
| | - Fernando Salvador
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain.
- International Health Unit Vall d'Hebron-Drassanes, Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS, Barcelona, Spain.
| | - Pedro Fernández-Soto
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, Salamanca, Spain.
| |
Collapse
|
3
|
Febrer-Sendra B, Crego-Vicente B, Nindia A, Martínez-Campreciós J, Aixut S, Mediavilla A, Silgado A, Oliveira-Souto I, Salvador F, Molina I, Muro A, Sulleiro E, Fernández-Soto P. First field and laboratory evaluation of LAMP assay for malaria diagnosis in Cubal, Angola. Parasit Vectors 2023; 16:343. [PMID: 37789462 PMCID: PMC10548721 DOI: 10.1186/s13071-023-05942-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 08/22/2023] [Indexed: 10/05/2023] Open
Abstract
BACKGROUND Malaria is a globally distributed infectious disease. According to the World Health Organization, Angola is one of the six countries that account for over half the global malaria burden in terms of both malaria cases and deaths. Diagnosis of malaria still depends on microscopic examination of thin and thick blood smears and rapid diagnostic tests (RDTs), which often lack analytical and clinical sensitivity. Molecular methods could overcome these disadvantages. The aim of this study was to evaluate, for the first time to our knowledge, the performance of a loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria in an endemic area in Cubal, Angola, and to assess the reproducibility at a reference laboratory. METHODS A total of 200 blood samples from patients attended at Hospital Nossa Senhora da Paz, Cubal, Angola, were analysed for Plasmodium spp. detection by microscopy, RDTs, and LAMP. LAMP assay was easily performed in a portable heating block, and the results were visualized by a simple colour change. Subsequently, the samples were sent to a reference laboratory in Spain to be reanalysed by the same colorimetric LAMP assay and also in real-time LAMP format. RESULTS In field tests, a total of 67/200 (33.5%) blood samples were microscopy-positive for Plasmodium spp., 98/200 RDT positive, and 112/200 (56%) LAMP positive. Using microscopy as reference standard, field LAMP detected more microscopy-positive samples than RDTs (66/67; 98% vs. 62/67; 92.5%). When samples were reanalysed at a reference laboratory in Spain using both colorimetric and real-time assays, the overall reproducibility achieved 84.5%. CONCLUSIONS This is the first study to our knowledge in which LAMP has been clinically evaluated on blood samples in a resource-poor malaria-endemic area. The colorimetric LAMP proved to be more sensitive than microscopy and RDTs for malaria diagnosis in field conditions. Furthermore, LAMP showed an acceptable level of reproducibility in a reference laboratory. The possibility to use LAMP in a real-time format in a portable device reinforces the reliability of the assay for molecular diagnosis of malaria in resource-poor laboratories in endemic areas.
Collapse
Affiliation(s)
- Begoña Febrer-Sendra
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Salamanca, Spain
| | - Beatriz Crego-Vicente
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Salamanca, Spain
| | | | - Joan Martínez-Campreciós
- Hospital Nossa Senhora da Paz, Cubal, Angola
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | | | - Alejandro Mediavilla
- Microbiology Department Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain
| | - Aroa Silgado
- Microbiology Department Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain
| | - Inés Oliveira-Souto
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
- International Health Unit Vall d'Hebron-Drassanes, Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain
| | - Fernando Salvador
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
- International Health Unit Vall d'Hebron-Drassanes, Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain
| | - Israel Molina
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
- International Health Unit Vall d'Hebron-Drassanes, Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain
| | - Antonio Muro
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Salamanca, Spain
| | - Elena Sulleiro
- Microbiology Department Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain.
- International Health Unit Vall d'Hebron-Drassanes, Infectious Diseases Department, Vall d'Hebron University Hospital, PROSICS Barcelona, Barcelona, Spain.
| | - Pedro Fernández-Soto
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Salamanca, Spain.
| |
Collapse
|
4
|
Collaborative trial validation of a new multiplex real-time PCR to sensitively detect allergenic nuts in food. J Verbrauch Lebensm 2022. [DOI: 10.1007/s00003-022-01385-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
AbstractIn this article, we present a multiplex real-time PCR method for a simultaneous, sensitive and specific detection and semi-quantitative estimation of the allergenic species peanut, hazelnut, walnut and cashew in food. Due to the use of multicopy target sequences, a very sensitive detection of the allergenic ingredients was possible. The method was validated in-house as well as by a collaborative trial with 12 laboratories. Within the ring trial, 0.64 mg/kg (i.e. approx. 0.1–0.2 mg of peanut and tree nut-derived protein/kg) could still be detected in a processed cookie matrix, confirmed by results of incurred, processed samples spiked at very low levels between 0.9 and 50 mg/kg of the corresponding allergenic ingredient (peanut, tree nut). In addition, the method revealed good precision data. With regard to quantitative analysis though, insufficient recovery data (bias) were determined in some cases, resulting in measurement uncertainties of more than 50%.
Collapse
|
5
|
Li J, Jiang J, Su Y, Liang Y, Zhang C. A novel cloth-based supersandwich electrochemical aptasensor for direct, sensitive detection of pathogens. Anal Chim Acta 2021; 1188:339176. [PMID: 34794578 DOI: 10.1016/j.aca.2021.339176] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 10/04/2021] [Accepted: 10/13/2021] [Indexed: 01/07/2023]
Abstract
Traditional detection methods for food-borne pathogens are usually expensive and laborious, so there is an urgent need for an economical, facile and sensitive method. In this work, a novel cloth-based supersandwich electrochemical aptasensor (CSEA) is firstly developed for direct detection of pathogens. Carbon ink- and wax-based screen-printing is used to make cloth-based electrodes and hydrophilic/hydrophobic regions respectively to fabricate the sensing devices. Two well-designed, specific single-stranded DNA sequences arise a cascade hybridization reaction to form the DNA supersandwich (DSS) whose grooves can be inserted by methylene blue (MB), which effectively amplifies the current signal to greatly improve the detection sensitivity. Taking the detection of Salmonella typhimurium (S. typhimurium) as an example, the aptamers bind to S. typhimurium to form the target-aptamers complex, which can simultaneously bind to the capture probe and DSS, resulting in detection of S. typhimurium. Moreover, the addition of tail sequences of aptamer makes the proposed CSEA versatile. Under optimized conditions, the electrochemical signal increases linearly with the logarithm of S. typhimurium concentration over the range from 102 to 108 CFU mL-1, with a limit of detection of 16 CFU mL-1. Additionally, the CSEA efficiently determined the levels of S. typhimurium in milk samples. Experimental results illustrate that the fabricated CSEA is sensitive, specific, reproducible and stable. Moreover, when Ru(bpy)32+ replaces MB, the electrochemiluminescence (ECL) can be performed. Thus, for the proposed sensing strategy, the dual-mode detection of electrochemistry and ECL is easily realized.
Collapse
Affiliation(s)
- Jie Li
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Jun Jiang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Yan Su
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Yi Liang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| |
Collapse
|
6
|
Encapsulation of Large-Size Plasmids in PLGA Nanoparticles for Gene Editing: Comparison of Three Different Synthesis Methods. NANOMATERIALS 2021; 11:nano11102723. [PMID: 34685164 PMCID: PMC8541650 DOI: 10.3390/nano11102723] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 10/07/2021] [Accepted: 10/08/2021] [Indexed: 12/12/2022]
Abstract
The development of new gene-editing technologies has fostered the need for efficient and safe vectors capable of encapsulating large nucleic acids. In this work we evaluate the synthesis of large-size plasmid-loaded PLGA nanoparticles by double emulsion (considering batch ultrasound and microfluidics-assisted methodologies) and magnetic stirring-based nanoprecipitation synthesis methods. For this purpose, we characterized the nanoparticles and compared the results between the different synthesis processes in terms of encapsulation efficiency, morphology, particle size, polydispersity, zeta potential and structural integrity of loaded pDNA. Our results demonstrate particular sensibility of large pDNA for shear and mechanical stress degradation during double emulsion, the nanoprecipitation method being the only one that preserved plasmid integrity. However, plasmid-loaded PLGA nanoparticles synthesized by nanoprecipitation did not show cell expression in vitro, possibly due to the slow release profile observed in our experimental conditions. Strong electrostatic interactions between the large plasmid and the cationic PLGA used for this synthesis may underlie this release kinetics. Overall, none of the methods evaluated satisfied all the requirements for an efficient non-viral vector when applied to large-size plasmid encapsulation. Further optimization or alternative synthesis methods are thus in current need to adapt PLGA nanoparticles as delivery vectors for gene editing therapeutic technologies.
Collapse
|
7
|
Tan X, Ge L, Zhang T, Lu Z. Preservation of DNA for data storage. RUSSIAN CHEMICAL REVIEWS 2021. [DOI: 10.1070/rcr4994] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The preservation of DNA has attracted significant interest of scientists in diverse research fields from ancient biological remains to the information field. In light of the different DNA safekeeping requirements (e.g., storage time, storage conditions) in these disparate fields, scientists have proposed distinct methods to maintain the DNA integrity. Specifically, DNA data storage is an emerging research, which means that the binary digital information is converted to the sequences of nucleotides leading to dense and durable data storage in the form of synthesized DNA. The intact preservation of DNA plays a significant role because it is closely related to data integrity. This review discusses DNA preservation methods, aiming to confirm an appropriate one for synthetic oligonucleotides in DNA data storage. First, we analyze the impact factors of the DNA long-term storage, including the intrinsic stability of DNA, environmental factors, and storage methods. Then, the benefits and disadvantages of diverse conservation approaches (e.g., encapsulation-free, chemical encapsulation) are discussed. Finally, we provide advice for storing non-genetic information in DNA in vitro. We expect these preservation suggestions to promote further research that may extend the DNA storage time.
The bibliography includes 99 references.
Collapse
|
8
|
Sharma L, Watts E, Singh P. High resolution real-time PCR melting curve assay for identification of top five Penaeidae shrimp species. Lebensm Wiss Technol 2020. [DOI: 10.1016/j.lwt.2020.109983] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
9
|
Minso R, Schulz A, Dopfer C, Alfeis N, Barneveld AV, Makartian-Gyulumyan L, Hansen G, Junge S, Müller C, Ringshausen FCC, Sauer-Heilborn A, Stanke F, Stolpe C, Tamm S, Welte T, Dittrich AM, Tümmler B. Intestinal current measurement and nasal potential difference to make a diagnosis of cases with inconclusive CFTR genetics and sweat test. BMJ Open Respir Res 2020; 7:e000736. [PMID: 33020115 PMCID: PMC7537139 DOI: 10.1136/bmjresp-2020-000736] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 08/31/2020] [Accepted: 09/05/2020] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Nasal potential difference (NPD) and intestinal current measurements (ICM) are cystic fibrosis transmembrane conductance regulator (CFTR) biomarkers recommended to make a diagnosis in individuals with inconclusive sweat test and CFTR genetics and a clinical suspicion for cystic fibrosis (CF) or CFTR-related disorder (CFTR-RD). METHODS NPD and ICM were measured according to standard operating procedures of the European Cystic Fibrosis Society Diagnostic Network Working Group. RESULTS We assessed 219 individuals by NPD or ICM who had been referred to our laboratory due to clinical symptoms suggestive of CF, but inconclusive sweat test and CFTR genetics (median age: 16.3 years, range 0.4 to 76 years). CF or CFTR-related disorder was diagnosed in 22 of 29 patients (76%) with a CFTR genotype of unknown or variable clinical significance and in 51 of 190 carriers (27%) of one (35/42) or no (16/148) identified CFTR mutation. If two CFTR sequence variants had been identified, the outcome of NPD and ICM was consistent with the classification of the CFTR2 database. Moreover, a suspected false-positive diagnosis of CF was confirmed in seven and withdrawn in eight patients. Of 26 individuals assessed by both NPD and ICM, eleven individuals exhibited discordant tracings of ICM and NPD, with one measurement being in the CF range and the other in the normal range. CONCLUSION The majority of patients whom we diagnosed with CF or CFTR-RD by extended electrophysiology are carriers of the wild-type CFTR coding sequence on at least one of their CF alleles. The disease-causing genetic lesions should reside in the non-coding region of CFTR or elsewhere in the genome, affecting the regulation of CFTR expression in a tissue-depending fashion which may explain the large within-group variability of CFTR activity in the respiratory and intestinal epithelium seen in this group.
Collapse
Affiliation(s)
- Rebecca Minso
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
| | - Angela Schulz
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
| | - Christian Dopfer
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research DZL, Hannover, Germany
| | - Nadine Alfeis
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
| | - Andrea van Barneveld
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Klinische Forschergruppe, OE 6710, Medizinische Hochschule Hannover, Hannover, Germany
| | - Lena Makartian-Gyulumyan
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Klinische Forschergruppe, OE 6710, Medizinische Hochschule Hannover, Hannover, Germany
| | - Gesine Hansen
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research DZL, Hannover, Germany
| | - Sibylle Junge
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
| | - Carsten Müller
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
| | - Felix C C Ringshausen
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research DZL, Hannover, Germany
- Department of Respiratory Medicine, Hannover Medical School, Hannover, Germany
| | | | - Frauke Stanke
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research DZL, Hannover, Germany
- Klinische Forschergruppe, OE 6710, Medizinische Hochschule Hannover, Hannover, Germany
| | - Cornelia Stolpe
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
| | - Stephanie Tamm
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Klinische Forschergruppe, OE 6710, Medizinische Hochschule Hannover, Hannover, Germany
| | - Tobias Welte
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research DZL, Hannover, Germany
- Department of Respiratory Medicine, Hannover Medical School, Hannover, Germany
| | - Anna-Maria Dittrich
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research DZL, Hannover, Germany
| | - Burkhard Tümmler
- Clinic for Paediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- Biomedical Research in Endstage and Obstructive Lung Disease (BREATH), German Center for Lung Research DZL, Hannover, Germany
- Klinische Forschergruppe, OE 6710, Medizinische Hochschule Hannover, Hannover, Germany
| |
Collapse
|
10
|
Baoutina A, Bhat S, Partis L, Emslie KR. Storage Stability of Solutions of DNA Standards. Anal Chem 2019; 91:12268-12274. [DOI: 10.1021/acs.analchem.9b02334] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Anna Baoutina
- National Measurement Institute (NMI), Lindfield, Sydney, New South Wales 2070, Australia
| | - Somanath Bhat
- National Measurement Institute (NMI), Lindfield, Sydney, New South Wales 2070, Australia
| | - Lina Partis
- National Measurement Institute (NMI), Lindfield, Sydney, New South Wales 2070, Australia
| | - Kerry R. Emslie
- National Measurement Institute (NMI), Lindfield, Sydney, New South Wales 2070, Australia
| |
Collapse
|
11
|
Grześkowiak Ł, Riedmüller J, Vahjen W, Zentek J. Storage procedures and time influence the detectability of Clostridium difficile toxin A but not toxin B in porcine fecal specimens. J Vet Diagn Invest 2019; 32:222-225. [PMID: 31328697 PMCID: PMC7081514 DOI: 10.1177/1040638719864383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Storage procedures are known to affect the detectability of Clostridium difficile toxins in equine and human feces. We assessed the impact of different storage conditions on the detectability of C. difficile toxins in swine feces. Specimens were inoculated with toxins, 112 ng/g of toxin A (TcdA) and 16 ng/g of toxin B (TcdB) and subjected to the following 3 storage treatments: 4°C, −30°C, repetitive freezing at −30°C and thawing. Toxin determination was assessed at 1, 2, 7, 14, and 21 d with ELISA. A decrease in concentrations of TcdA with time was observed for samples stored at 4°C and repetitive freezing–thawing (p ≤0.05). On day 14, storage at 4°C resulted in decreased TcdA concentration as opposed to storage at −30°C and repetitive freezing–thawing (p ≤0.05). On day 21, storage at 4°C resulted in decreased TcdA detectability compared with storage at −30°C (p ≤0.05). The TcdB concentration was unaffected. These results on toxin detectability in swine feces should be carefully considered in in vitro studies on toxigenic C. difficile. Our results also offer valuable information for microbiologists and veterinarians monitoring the presence of virulent C. difficile in pigs.
Collapse
Affiliation(s)
- Łukasz Grześkowiak
- Institute of Animal Nutrition, Freie Universität Berlin, Berlin, Germany
| | | | - Wilfried Vahjen
- Institute of Animal Nutrition, Freie Universität Berlin, Berlin, Germany
| | - Jürgen Zentek
- Institute of Animal Nutrition, Freie Universität Berlin, Berlin, Germany
| |
Collapse
|
12
|
Comparison of Loop-Mediated Isothermal Amplification and Real-Time PCR Assays for Detection of Strongyloides Larvae in Different Specimen Matrices. J Clin Microbiol 2019; 57:JCM.01173-18. [PMID: 30728195 DOI: 10.1128/jcm.01173-18] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 01/29/2019] [Indexed: 12/27/2022] Open
Abstract
Strongyloides stercoralis can cause disease that ranges from asymptomatic chronic infection to fatal hyperinfection. Diagnosis from stool can be challenging because the most sensitive conventional tests require live larvae to be effective and there can be low larval output in chronic infection. Nucleic acid amplification tests (NAAT) have been developed to complement existing diagnostic methods. We compared a recently developed loop-mediated isothermal amplification (LAMP) assay with a real-time PCR that has previously been validated with larval microscopy. The limits of detection-quantified using serial dilutions of DNA extracts from single Strongyloides ratti third-stage (L3) larvae spiked into approximately 250 µl of 5 different S. stercoralis-negative stool specimens-were 10-3 (1/5 replicates) and 10-2 (1/5 replicates) dilutions for PCR and LAMP, respectively. PCR was positive for 4/5 replicates at 10-2 LAMP was compared to PCR using extracts from 396 stool specimens collected in Bangladesh and Australia, of which 53 were positive and 343 were negative by PCR. The positive percentage agreement of LAMP was 77.3% (95% score confidence interval [CI], 64.5 to 86.6). The negative percentage agreement was 100% (95% CI, 98.9 to 100). In a preliminary investigation, PCR and LAMP assays were positive using DNA extracted from serum (PCR, 3/16 extracts; LAMP, 2/16 extracts) and bronchoalveolar lavage fluid (PCR and LAMP, 2/2 extracts), demonstrating proof of concept. Compared to PCR, the lower number of positive results using the LAMP assay may have been due to reaction inhibitors and DNA degradation, and strategies to improve the LAMP assay are discussed.
Collapse
|
13
|
Mikutis G, Schmid L, Stark WJ, Grass RN. Length-dependent DNA degradation kinetic model: Decay compensation in DNA tracer concentration measurements. AIChE J 2018. [DOI: 10.1002/aic.16433] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Gediminas Mikutis
- Dept. of Chemistry and Applied Biosciences, Functional Materials Laboratory; ETH Zurich; Vladimir-Prelog-Weg 1, CH-8093 Zurich Switzerland
| | - Lucius Schmid
- Dept. of Chemistry and Applied Biosciences, Functional Materials Laboratory; ETH Zurich; Vladimir-Prelog-Weg 1, CH-8093 Zurich Switzerland
| | - Wendelin J. Stark
- Dept. of Chemistry and Applied Biosciences, Functional Materials Laboratory; ETH Zurich; Vladimir-Prelog-Weg 1, CH-8093 Zurich Switzerland
| | - Robert N. Grass
- Dept. of Chemistry and Applied Biosciences, Functional Materials Laboratory; ETH Zurich; Vladimir-Prelog-Weg 1, CH-8093 Zurich Switzerland
| |
Collapse
|
14
|
Fattorini P, Marrubini G, Bonin S, Bertoglio B, Grignani P, Recchia E, Pitacco P, Procopio F, Cantoni C, Pajnič IZ, Sorçaburu-Cigliero S, Previderè C. Producing standard damaged DNA samples by heating: pitfalls and suggestions. Anal Biochem 2018; 549:107-112. [PMID: 29551671 DOI: 10.1016/j.ab.2018.03.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 03/08/2018] [Accepted: 03/12/2018] [Indexed: 11/29/2022]
Abstract
Heat-mediated hydrolysis of DNA is a simple and inexpensive method for producing damaged samples in vitro. Despite heat-mediated DNA hydrolysis is being widely used in forensic and clinical validation procedures, the lack of standardized procedures makes it impossible to compare the intra and inter-laboratory outcomes of the damaging treatments. In this work, a systematic approach to heat induced DNA hydrolysis was performed at 70 °C for 0-18 h to test the role both of the hydrolysis buffer and of the experimental conditions. Specifically, a trial DNA sample, resuspended in three different media (ultrapure water, 0.1% DEPC-water and, respectively, TE) was treated both in Eppendorf tubes ("Protocol P") and in Eppendorf tubes provided with screwcaps ("Protocol S"). The results of these comparative tests were assessed by normalization of the qPCR results. DEPC-water increased the degradation of the samples up to about 100 times when compared to the ultrapure water. Conversely, the TE protected the DNA from degradation whose level was about 1700 times lower than in samples treated in ultrapure water. Even the employment of the "Protocol S" affected the level of degradation, by consistently increasing it (up to about 180 times in DEPC-water). Thus, this comparative approach showed that even seemingly apparently trivial and often underestimated parameters modify the degradation level up to 2-3 orders of magnitude. The chemical-physical reasons of these findings are discussed together with the role of potential factors such as enhanced reactivity of CO2, ROS, NOx and pressure, which are likely to be involved. Since the intra and inter-laboratory comparison of the outcomes of the hydrolytic procedure is the first step toward its standardization, the normalization of the qPCR data by the UV/qPCR ratio seems to be the simplest and most reliable way to allow this. Finally, the supplying (provided with the commercial qPCR kits) of a DNA sample whose degree of degradation is well documented could be helpful in ISO/IEC 17025 validation procedures and in proficiency testing.
Collapse
Affiliation(s)
- Paolo Fattorini
- Department of Medicine, Surgery and Health, University of Trieste, Italy.
| | | | - Serena Bonin
- Department of Medicine, Surgery and Health, University of Trieste, Italy
| | - Barbara Bertoglio
- Department of Public Health, Experimental and Forensic Medicine, Section of Legal Medicine and Forensic Sciences, University of Pavia, Italy
| | - Pierangela Grignani
- Department of Public Health, Experimental and Forensic Medicine, Section of Legal Medicine and Forensic Sciences, University of Pavia, Italy
| | - Elisa Recchia
- Department of Medicine, Surgery and Health, University of Trieste, Italy
| | - Paola Pitacco
- Department of Medicine, Surgery and Health, University of Trieste, Italy
| | - Francesca Procopio
- School of Biological and Chemical Sciences, Queen Mary University of London, United Kingdom
| | | | - Irena Zupanič Pajnič
- Institute of Forensic Medicine, Faculty of Medicine, University of Ljubljana, Slovenia
| | | | - Carlo Previderè
- Department of Public Health, Experimental and Forensic Medicine, Section of Legal Medicine and Forensic Sciences, University of Pavia, Italy
| |
Collapse
|
15
|
Tal M, Verbrugghe A, Gomez DE, Chau C, Weese JS. The effect of storage at ambient temperature on the feline fecal microbiota. BMC Vet Res 2017; 13:256. [PMID: 28821259 PMCID: PMC5563020 DOI: 10.1186/s12917-017-1188-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Accepted: 08/10/2017] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Feline fecal microbiota analyses can potentially be impacted by a variety of factors such as sample preparation, sequencing method and bioinformatics analyses. Another potential influence is changes in the microbiota from storage of samples prior to processing. This study examined the effect of ambient temperature exposure on the feline fecal microbiota composition. Fecal samples were collected from 12 healthy cats, within 15 min after defecation. Samples were aliquoted and the first aliquot was frozen at -80 °C within 1 hour of defecation. Remaining aliquots were maintained at ambient temperature (20 to 23 °C) and frozen at -80 °C at 6, 12, 24, 36, 48, 72 and 96 h after collection. DNA was extracted from all aliquots, and polymerase chain reaction (PCR). The PCR products were sequenced with next-generation sequencing (Illumina MiSeq). RESULTS No significant differences were observed in alpha and beta biodiversity indexes, as well as relative abundance of different taxa over time (P > 0.05 for all tests between time points). Principal coordinate analyses demonstrated that samples cluster mainly by cat, with no significant differences between time points (AMOVA, P > 0.05; HOMOVA, P > 0.05). Linear discriminant analysis effect size method was performed and failed to detect any enriched taxa, between time points. Random forest algorithm analysis indicated homogeneity across time points. CONCLUSIONS Although existing evidence from human fecal storage studies is contradictory, a recent study in companion animals agreed with the current study, demonstrating that maintenance of feline fecal samples at ambient temperature for up to 4 days has no effect on the bacterial membership and structure.
Collapse
Affiliation(s)
- Moran Tal
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1 Canada
| | - Adronie Verbrugghe
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1 Canada
| | - Diego E. Gomez
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1 Canada
- College of Veterinary Medicine, University of Florida, Gainesville, Florida USA
| | - Charlotte Chau
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1 Canada
| | - J. Scott Weese
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1 Canada
| |
Collapse
|
16
|
Payne DA, Baluchova K, Peoc'h KH, van Schaik RHN, Chan KCA, Maekawa M, Mamotte C, Russomando G, Rousseau F, Ahmad-Nejad P. Pre-examination factors affecting molecular diagnostic test results and interpretation: A case-based approach. Clin Chim Acta 2016; 467:59-69. [PMID: 27321365 DOI: 10.1016/j.cca.2016.06.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 06/13/2016] [Accepted: 06/15/2016] [Indexed: 12/13/2022]
Abstract
BACKGROUND Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. METHODS The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. CONCLUSIONS The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics.
Collapse
Affiliation(s)
- Deborah A Payne
- Molecular Services, APP-UniPath LLC, American Pathology Partners-UniPath, 6116 East Warren Ave., Denver, CO, USA.
| | - Katarina Baluchova
- Comenius University in Bratislava, Jessenius Faculty of Medicine in Martin, Biomedical Center Martin, Division of Oncology, Mala Hora 4C, 036 01 Martin, Slovakia; Comenius University in Bratislava, Jessenius Faculty of Medicine in Martin, Department of Molecular Biology, Mala Hora 4C, 036 01 Martin, Slovakia
| | - Katell H Peoc'h
- AP-HP Hôpital Beaujon, Service de Biochimie clinique, Clichy F-92118, France; Université Paris Diderot, UFR de Médecine site Bichat, INSERM UMRs-1149, Paris, France
| | - Ron H N van Schaik
- Department Clinical Chemistry, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - K C Allen Chan
- Department of Chemical Pathology, Li Ka Shing Institute of Health Sciences, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong
| | - Masato Maekawa
- Department of Laboratory Medicine, Hamamatsu University School of Medicine, Hamamatsu, Japan
| | - Cyril Mamotte
- School of Biomedical Sciences and CHIRI Biosciences, Curtin University, Perth, Australia
| | - Graciela Russomando
- Molecular Biology and Biotechnology Department, Instituto de Investigaciones en Ciencias de la Salud, Universidad Nacional de Asunción, Paraguay
| | - François Rousseau
- Department of Medical Biology, Direction médicale des services hospitaliers, CHU de Québec - Université Laval, Québec City, Canada; Department of Molecular Biology, Medical Biochemistry and Pathology, Faculty of Medicine, Université Laval, Québec City, Canada
| | - Parviz Ahmad-Nejad
- Institute for Medical Laboratory Diagnostics, Centre for Clinical and Translational Research (CCTR), HELIOS Hospital, Heusnerstraße 40, 42283 Wuppertal, Witten/Herdecke University, Germany
| |
Collapse
|
17
|
Urubschurov V, Büsing K, Janczyk P, Souffrant WB, Zeyner A. Development and Evaluation of qPCR Assay for Quantitation of Kazachstania slooffiae and Total Yeasts Occurring in the Porcine Gut. Curr Microbiol 2015; 71:373-81. [PMID: 26134536 DOI: 10.1007/s00284-015-0862-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 05/04/2015] [Indexed: 10/23/2022]
Abstract
Kazachstania slooffiae is the dominating yeast in pig's gut. No methods others than cultivation were applied for enumeration of yeasts within this ecosystem. Therefore, the aim of this study was to develop a real-time quantitative polymerase chain reaction (qPCR) assay to quantitate total yeasts and K. slooffiae in the porcine gut. This work demonstrated that the copy numbers in gDNA can be determined by qPCR using PCR amplicons as a calibrator and one-point calibration method. The gDNA were then used as a calibrator for further analysis. The values of quantitation cycle and PCR amplification efficiency of gDNA calibrator were highly reproducible. DNA was extracted from feces and from 10 different cultured yeasts found in pigs' intestine. The qPCR results using primers NL1/LS2 encoding 26S rDNA correlated (r = 0.984, P < 0.0001) with cultivation results. From two primer sets developed, one set encoding act1 gene was suitable for quantitation of K. slooffiae. The copy numbers of K. slooffiae could be determined by 40% analyzed animals, amounting to about 70% of total yeasts. The application of this method in next studies will help to get more information about K. slooffiae and total yeasts in the gut of pigs.
Collapse
Affiliation(s)
- Vladimir Urubschurov
- Institute of Agricultural and Nutritional Sciences, Group Animal Nutrition, Martin Luther University Halle-Wittenberg, Theodor-Lieser-Straße 11, 06120, Halle (Saale), Germany,
| | | | | | | | | |
Collapse
|
18
|
Krüger NJ, Buhler C, Iwobi AN, Huber I, Ellerbroek L, Appel B, Stingl K. "Limits of control"--crucial parameters for a reliable quantification of viable campylobacter by real-time PCR. PLoS One 2014; 9:e88108. [PMID: 24505398 PMCID: PMC3914927 DOI: 10.1371/journal.pone.0088108] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Accepted: 01/07/2014] [Indexed: 11/19/2022] Open
Abstract
The unsuitability of the "CFU" parameter and the usefulness of cultivation-independent quantification of Campylobacter on chicken products, reflecting the actual risk for infection, is increasingly becoming obvious. Recently, real-time PCR methods in combination with the use of DNA intercalators, which block DNA amplification from dead bacteria, have seen wide application. However, much confusion exists in the correct interpretation of such assays. Campylobacter is confronted by oxidative and cold stress outside the intestine. Hence, damage caused by oxidative stress probably represents the most frequent natural death of Campylobacter on food products. Treatment of Campylobacter with peroxide led to complete loss of CFU and to significant entry of any tested DNA intercalator, indicating disruption of membrane integrity. When we transiently altered the metabolic state of Campylobacter by abolishing the proton-motive force or by inhibiting active efflux, CFU was constant but enhanced entry of ethidium bromide (EtBr) was observed. Consistently, ethidium monoazide (EMA) also entered viable Campylobacter, in particular when nutrients for bacterial energization were lacking (in PBS) or when the cells were less metabolically active (in stationary phase). In contrast, propidium iodide (PI) and propidium monoazide (PMA) were excluded from viable bacterial cells, irrespective of their metabolic state. As expected for a diffusion-limited process, the extent of signal reduction from dead cells depended on the temperature, incubation time and concentration of the dyes during staining, prior to crosslinking. Consistently, free protein and/or DNA present in varying amounts in the heterogeneous matrix lowered the concentration of the DNA dyes at the bacterial membrane and led to considerable variation of the residual signal from dead cells. In conclusion, we propose an improved approach, taking into account principles of method variability and recommend the implementation of process sample controls for reliable quantification of intact and potentially infectious units (IPIU) of Campylobacter by real-time PCR.
Collapse
Affiliation(s)
- Nora-Johanna Krüger
- National Reference Laboratory for Campylobacter, Federal Institute for Risk Assessment, Berlin, Germany
| | - Christiane Buhler
- National Reference Laboratory for Campylobacter, Federal Institute for Risk Assessment, Berlin, Germany
| | - Azuka N. Iwobi
- Bavarian Health and Food Safety Authority, Oberschleißheim, Germany
| | - Ingrid Huber
- Bavarian Health and Food Safety Authority, Oberschleißheim, Germany
| | - Lüppo Ellerbroek
- National Reference Laboratory for Campylobacter, Federal Institute for Risk Assessment, Berlin, Germany
| | - Bernd Appel
- National Reference Laboratory for Campylobacter, Federal Institute for Risk Assessment, Berlin, Germany
| | - Kerstin Stingl
- National Reference Laboratory for Campylobacter, Federal Institute for Risk Assessment, Berlin, Germany
- * E-mail:
| |
Collapse
|
19
|
Rajatileka S, Luyt K, El-Bokle M, Williams M, Kemp H, Molnár E, Váradi A. Isolation of human genomic DNA for genetic analysis from premature neonates: a comparison between newborn dried blood spots, whole blood and umbilical cord tissue. BMC Genet 2013; 14:105. [PMID: 24168095 PMCID: PMC3817355 DOI: 10.1186/1471-2156-14-105] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2013] [Accepted: 09/17/2013] [Indexed: 12/17/2022] Open
Abstract
Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Anikó Váradi
- Centre for Research in Biosciences, Department of Biological, Biomedical and Analytical Sciences, Faculty of Health and Applied Sciences, University of the West of England, Bristol BS16 1QY, UK.
| |
Collapse
|
20
|
Viljoen CD, Thompson GG, Sreenivasan S. Stability of ultramer as copy number standards in real-time PCR. Gene 2013; 516:143-5. [DOI: 10.1016/j.gene.2012.12.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2012] [Accepted: 12/02/2012] [Indexed: 11/17/2022]
|
21
|
Pakpour S, Milani AS, Chénier MR. A multi-criteria decision-making approach for comparing sample preservation and DNA extraction methods from swine feces. ACTA ACUST UNITED AC 2012. [DOI: 10.4236/ajmb.2012.22018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|