1
|
Jin Y, Meng LJ. Exploration of Coincidence Detection of Cascade Photons to Enhance Preclinical Multi-Radionuclide SPECT Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:1766-1781. [PMID: 38163304 DOI: 10.1109/tmi.2023.3348756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
We proposed a technique of coincidence detection of cascade photons (CDCP) to enhance preclinical SPECT imaging of therapeutic radionuclides emitting cascade photons, such as Lu-177, Ac-225, Ra-223, and In-111. We have carried out experimental studies to evaluate the proposed CDCP-SPECT imaging of low-activity radionuclides using a prototype coincidence detection system constructed with large-volume cadmium zinc telluride (CZT) imaging spectrometers and a pinhole collimator. With In-111 in experimental studies, the CDCP technique allows us to improve the signal-to-contamination in the projection (Projection-SCR) by ~53 times and reduce ~98% of the normalized contamination. Compared to traditional scatter correction, which achieves a Projection-SCR of 1.00, our CDCP method boosts it to 15.91, showing enhanced efficacy in reducing down-scattered contamination, especially at lower activities. The reconstructed images of a line source demonstrated the dramatic enhancement of the image quality with CDCP-SPECT compared to conventional and triple-energy-window-corrected SPECT data acquisition. We also introduced artificial energy blurring and Monte Carlo simulation to quantify the impact of detector performance, especially its energy resolution and timing resolution, on the enhancement through the CDCP technique. We have further demonstrated the benefits of the CDCP technique with simulation studies, which shows the potential of improving the signal-to-contamination ratio by 300 times with Ac-225, which emits cascade photons with a decay constant of ~0.1 ns. These results have demonstrated the potential of CDCP-enhanced SPECT for imaging a super-low level of therapeutic radionuclides in small animals.
Collapse
|
2
|
Ochoa-Figueroa M, Frias-Rose J, Good E, Sanchez-Rodriguez V, Davidsson A, Pagonis C. Diagnostic performance of different cardiac stress protocols for myocardial perfusion imaging for the diagnosis of coronary artery disease using a cadmium-zinc-telluride camera with invasive coronary angiography correlation. Rev Esp Med Nucl Imagen Mol 2023; 42:281-288. [PMID: 36103979 DOI: 10.1016/j.remnie.2022.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 11/08/2021] [Accepted: 01/23/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the diagnostic performance of three different cardiac stress protocols for myocardial perfusion imaging (MPI) using a cadmium-zinc-telluride (CZT) camera with invasive coronary angiography (ICA) correlation for the diagnosis of coronary artery disease in a high risk population. METHODS Retrospective study of 263 patients (96 women and 167 males, mean age 68 years) from which 119 patients performed a bicycle stress test (BST), 113 pharmacological stress test (PST) and 31 a combination of the two (CST) between September 2014 and December 2018. The patients then underwent myocardial perfusion imaging (MPI), followed by ICA and evaluated by means of quantitative angiography software, within six months after the MPI. The mean pre-test probability score for coronary disease according to the European Society of Cardiology criteria was 36% for the whole population. The MPI was performed in a dedicated CZT cardio camera (D-SPECT Spectrum Dynamics) with a two-day protocol, according to the European Association of Nuclear Medicine guidelines. RESULTS No significant difference was observed between the three stress protocols in terms of diagnostic accuracy (BST 85%, PST 88%, CST 84%). The overall diagnostic accuracy of MPI to identify patients with any obstructive CAD at ICA was 86%, Sensitivity 93%, Specificity 54%, PPV 90% and NPV 63%. CONCLUSION The CZT D-SPECT camera achieves overall satisfactory results in the diagnosis of CAD, observing no significant differences in the diagnostic performance when the stress test was performed as a BST, PST or CST.
Collapse
Affiliation(s)
- Miguel Ochoa-Figueroa
- Department of Clinical Physiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Sweden; Department of Radiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
| | - Jeronimo Frias-Rose
- Department of Pathology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Sweden
| | - Elin Good
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden; Department of Cardiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Veronica Sanchez-Rodriguez
- Department of Clinical Physiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Sweden; Department of Radiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Anette Davidsson
- Department of Clinical Physiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Sweden
| | - Christos Pagonis
- Department of Cardiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
3
|
Arvidsson I, Davidsson A, Overgaard NC, Pagonis C, Åström K, Good E, Frias-Rose J, Heyden A, Ochoa-Figueroa M. Deep learning prediction of quantitative coronary angiography values using myocardial perfusion images with a CZT camera. J Nucl Cardiol 2023; 30:116-126. [PMID: 35610536 DOI: 10.1007/s12350-022-02995-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 03/15/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE Evaluate the prediction of quantitative coronary angiography (QCA) values from MPI, by means of deep learning. METHODS 546 patients (67% men) undergoing stress 99mTc-tetrofosmin MPI in a CZT camera in the upright and supine position were included (1092 MPIs). Patients were divided into two groups: ICA group included 271 patients who performed an ICA within 6 months of MPI and a control group with 275 patients with low pre-test probability for CAD and a normal MPI. QCA analyses were performed using radiologic software and verified by an expert reader. Left ventricular myocardium was segmented using clinical nuclear cardiology software and verified by an expert reader. A deep learning model was trained using a double cross-validation scheme such that all data could be used as test data as well. RESULTS Area under the receiver-operating characteristic curve for the prediction of QCA, with > 50% narrowing of the artery, by deep learning for the external test cohort: per patient 85% [95% confidence interval (CI) 84%-87%] and per vessel; LAD 74% (CI 72%-76%), RCA 85% (CI 83%-86%), LCx 81% (CI 78%-84%), and average 80% (CI 77%-83%). CONCLUSION Deep learning can predict the presence of different QCA percentages of coronary artery stenosis from MPIs.
Collapse
Affiliation(s)
- Ida Arvidsson
- Centre for Mathematical Sciences, Lund University, Lund, Sweden
| | - Anette Davidsson
- Department of Clinical Physiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, 581 85, Linköping, Sweden
| | | | - Christos Pagonis
- Department of Cardiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Kalle Åström
- Centre for Mathematical Sciences, Lund University, Lund, Sweden
| | - Elin Good
- Department of Cardiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Jeronimo Frias-Rose
- Department of Pathology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Anders Heyden
- Centre for Mathematical Sciences, Lund University, Lund, Sweden
| | - Miguel Ochoa-Figueroa
- Department of Clinical Physiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, 581 85, Linköping, Sweden.
- Department of Radiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
| |
Collapse
|
4
|
Assante R, D'Antonio A, Mannarino T, Nappi C, Gaudieri V, Zampella E, Buongiorno P, Cantoni V, Green R, Frega N, Verberne HJ, Petretta M, Cuocolo A, Acampa W. Simultaneous assessment of myocardial perfusion and adrenergic innervation in patients with heart failure by low-dose dual-isotope CZT SPECT imaging. J Nucl Cardiol 2022; 29:3341-3351. [PMID: 35378694 PMCID: PMC9834348 DOI: 10.1007/s12350-022-02951-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 03/06/2022] [Indexed: 01/22/2023]
Abstract
BACKGROUND In patients with heart failure (HF) sequential imaging studies have demonstrated a relationship between myocardial perfusion and adrenergic innervation. We evaluated the feasibility of a simultaneous low-dose dual-isotope 123I/99mTc-acquisition protocol using a cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) camera. METHODS AND RESULTS Thirty-six patients with HF underwent simultaneous low-dose 123I-metaiodobenzylguanidine (MIBG)/99mTc-sestamibi gated CZT-SPECT cardiac imaging. Perfusion and innervation total defect sizes and perfusion/innervation mismatch size (defined by 123I-MIBG defect size minus 99mTc-sestamibi defect size) were expressed as percentages of the total left ventricular (LV) surface area. LV ejection fraction (EF) significantly correlated with perfusion defect size (P < .005), innervation defect size (P < .005), and early (P < .05) and late (P < .01) 123I-MIBG heart-to-mediastinum (H/M) ratio. In addition, late H/M ratio was independently associated with reduced LVEF (P < .05). Although there was a significant relationship (P < .001) between perfusion and innervation defect size, innervation defect size was larger than perfusion defect size (P < .001). At multivariable linear regression analysis, 123I-MIBG washout rate (WR) correlated with perfusion/innervation mismatch (P < .05). CONCLUSIONS In patients with HF, a simultaneous low-dose dual-isotope 123I/99mTc-acquisition protocol is feasible and could have important clinical implications.
Collapse
Affiliation(s)
- Roberta Assante
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Adriana D'Antonio
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Teresa Mannarino
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Carmela Nappi
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy.
| | - Emilia Zampella
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Pietro Buongiorno
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Valeria Cantoni
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Roberta Green
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Nicola Frega
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Hein J Verberne
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, location AMC, University of Amsterdam, Amsterdam, The Netherlands
| | | | - Alberto Cuocolo
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Wanda Acampa
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Via Pansini 5, 80131, Naples, Italy
| |
Collapse
|
5
|
Taillefer R. Scintillation cameras: A new clinical era has come. J Nucl Cardiol 2022; 29:1942-1945. [PMID: 34254249 DOI: 10.1007/s12350-021-02660-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 04/09/2021] [Indexed: 12/22/2022]
Affiliation(s)
- Raymond Taillefer
- Department of Nuclear Medicine, Hôpital du Haut-Richelieu, CISSS de la Montérégie Centre, 920 Boulevard du Séminaire Nord, Saint-Jean-sur-Richelieu, Quebec, J3A 1B7, Canada.
| |
Collapse
|
6
|
Yamada Y, Nakano S, Gatate Y, Okano N, Muramatsu T, Nishimura S, Kuji I, Fukushima K, Matsunari I. Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction. J Nucl Cardiol 2021; 28:187-195. [PMID: 30603890 DOI: 10.1007/s12350-018-01585-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 12/17/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Simultaneous dual-tracer imaging using isotopes with close photo-peaks may benefit from improved properties of cadmium-zinc-telluride (CZT)-based scanners. METHODS Thirty patients having undergone primary percutaneous coronary intervention for acute myocardial infarction underwent single-(99mTc-tetrofosmin (TF) or 123I-BMIPP first) followed by simultaneous 99mTc-TF /123I-BMIPP dual-tracer imaging using a Discovery NM/CT 670 CZT. The values for the quantitative gated-SPECT (QGS) and the quantitative perfusion SPECT (QPS) were assessed. RESULTS The intra-class correlation (ICC) coefficients between the single- and dual-tracer imaging were high in all the QGS and QPS data (Summed motion score: 0.95, summed thickening score: 0.94, ejection fraction: 0.98, SRS for 99mTc-TF: 0.97/ for 123I-BMIPP: 0.95). Wall motion, wall thickening and rest scores per coronary-territory-based regions were also comparable between the single- and dual imaging (ICC coefficient > 0.91). The interrater concordance in the visual analysis for the infarction and perfusion-metabolism mismatch was significant for the global and regional left ventricle (P < 0.001). CONCLUSION The quantitative/semi-quantitative values for global and regional left-ventricular function, perfusion, and fatty acid metabolism were closely comparable between the dual-tracer imaging and the single-tracer mode. These data suggests the feasibility of the novel CZT-based scanner for the simultaneous 99mTc-TF /123I-BMIPP dual-tracer acquisitions in clinical settings.
Collapse
Affiliation(s)
- Yoshihiro Yamada
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shintaro Nakano
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan.
| | - Youdou Gatate
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Nanami Okano
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| | - Toshihiro Muramatsu
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shigeyuki Nishimura
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Ichiei Kuji
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Kenji Fukushima
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| |
Collapse
|
7
|
Songy B, Guernou M, Lussato D, Queneau M, Bonardel G, Grellier JF, Flahaut L, Nguyen D. Feasibility of simultaneous dual isotope acquisition for myocardial perfusion imaging with a cadmium zinc telluride camera. J Nucl Cardiol 2020; 27:737-747. [PMID: 30478657 DOI: 10.1007/s12350-018-1452-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 08/10/2018] [Indexed: 10/27/2022]
Abstract
BACKGROUND We studied the impact of technetium-99m (99mTc) in the thallium-201 (201Tl) energy window (70 keV) to determine if CZT cardiac cameras allow us to perform simultaneous dual-isotope acquisition for myocardial perfusion imaging. METHODS We included 117 consecutive patients. We injected 0.7 MBq/kg of 201Tl at stress, performed the first scan (image T1), then injected at rest 2 MBq/kg of 99mTc-tetrofosmin and immediately acquired a second scan with reconstruction in the energy window of thallium (image T2). A corrected thallium image was created by the subtraction of 99mTc downscattered photons (image TS). We compared spectra, image quality, and semiquantitative scores on T1, T2, and TS images. RESULTS Though T2 images were of worse quality, TS images were of equal quality compared to T1 images in most cases. Scores show an underestimation of abnormalities in 20% of patients on T2 images and in 10% on TS images. CONCLUSIONS Despite the improved energy resolution of CZT cameras, downscatter of technetium in the 201Tl window leads to an underestimation of the pathological territory in 10% to 20% of cases. It does not allow us to use simultaneous dual-isotope acquisition in clinical practice without additional tools for scatter correction.
Collapse
Affiliation(s)
- Bernard Songy
- Nuclear Cardiology, Centre Cardiologique du Nord (CCN), Saint-Denis, Paris, France.
| | - Mohamed Guernou
- Nuclear Cardiology, Centre Cardiologique du Nord (CCN), Saint-Denis, Paris, France
| | - David Lussato
- Nuclear Cardiology, Centre Cardiologique du Nord (CCN), Saint-Denis, Paris, France
| | - Mathieu Queneau
- Nuclear Cardiology, Centre Cardiologique du Nord (CCN), Saint-Denis, Paris, France
| | - Gerald Bonardel
- Nuclear Cardiology, Centre Cardiologique du Nord (CCN), Saint-Denis, Paris, France
| | | | - Ludovic Flahaut
- Nuclear Cardiology, Centre Cardiologique du Nord (CCN), Saint-Denis, Paris, France
| | - Duc Nguyen
- Nuclear Cardiology, Centre Cardiologique du Nord (CCN), Saint-Denis, Paris, France
| |
Collapse
|
8
|
Zampella E, Nappi C, Acampa W. Simultaneous dual isotope 201Tl/ 99mTc myocardial perfusion imaging using CZT cameras: Clinical utility or technical challenge? J Nucl Cardiol 2020; 27:748-750. [PMID: 30478659 DOI: 10.1007/s12350-018-01522-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Accepted: 11/02/2018] [Indexed: 10/27/2022]
Affiliation(s)
- Emilia Zampella
- Department of Advances Biomedical Sciences, University "Federico II", Naples, Italy
| | - Carmela Nappi
- Department of Advances Biomedical Sciences, University "Federico II", Naples, Italy
| | - Wanda Acampa
- Department of Advances Biomedical Sciences, University "Federico II", Naples, Italy.
| |
Collapse
|
9
|
Piekarski E, Manrique A, Rouzet F, Le Guludec D. Current Status of Myocardial Perfusion Imaging With New SPECT/CT Cameras. Semin Nucl Med 2020; 50:219-226. [PMID: 32284108 DOI: 10.1053/j.semnuclmed.2020.02.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Myocardial perfusion imaging (MPI) with Single-Photon Emission Computed Tomography (SPECT) has a major role in the management of coronary artery disease. Recent technological advances regarding SPECT detectors with the use of solid-state detectors has allowed for improved imaging quality since a decade with dramatic dose and/or time reduction of imaging protocols due to improved sensitivity and spatial resolution, and is now performed as a routine exam. Interestingly, this new technology has modified our everyday practice, from acquisition protocols (low dose and ultra-fast protocols) to image semiology. Numerous studies have shown how these technical advances have allowed for improved patient management, with similar or improved diagnostic and prognostic information derived from MPI. These improvements have also led to the straightforward implementation of myocardial blood flow measurement. This article reviews the current status of MPI using new SPECT and SPECT/CT cameras.
Collapse
Affiliation(s)
- Eve Piekarski
- Nuclear Medicine Department, Bichat Hospital, AP-HP, Paris, France; Université de Paris, Paris, France; Laboratory for Vascular Translational Science, INSERM, Paris, France
| | - Alain Manrique
- Normandie Univ, UNICAEN, Caen, France; Médecine Nucléaire, CHU de Caen, Caen, France; GIP Cyceron, Campus Jules Horowitz, Caen, France
| | - François Rouzet
- Nuclear Medicine Department, Bichat Hospital, AP-HP, Paris, France; Université de Paris, Paris, France; Laboratory for Vascular Translational Science, INSERM, Paris, France
| | - Dominique Le Guludec
- Nuclear Medicine Department, Bichat Hospital, AP-HP, Paris, France; Université de Paris, Paris, France; Laboratory for Vascular Translational Science, INSERM, Paris, France.
| |
Collapse
|
10
|
Slomka PJ, Miller RJ, Hu LH, Germano G, Berman DS. Solid-State Detector SPECT Myocardial Perfusion Imaging. J Nucl Med 2019; 60:1194-1204. [DOI: 10.2967/jnumed.118.220657] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 06/18/2019] [Indexed: 02/07/2023] Open
|
11
|
Hyafil F, Gimelli A, Slart RHJA, Georgoulias P, Rischpler C, Lubberink M, Sciagra R, Bucerius J, Agostini D, Verberne HJ. EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras. Eur J Hybrid Imaging 2019; 3:11. [PMID: 34191169 PMCID: PMC8218102 DOI: 10.1186/s41824-019-0058-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 06/10/2019] [Indexed: 01/28/2023] Open
Abstract
An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.
Collapse
Affiliation(s)
- Fabien Hyafil
- Department of Nuclear Medicine; Bichat University Hospital, Assistance Publique - Hôpitaux de Paris; Inserm UMR 1148, Paris Diderot-Paris 7 University, 46 rue Henri Huchard, 75018, Paris, France.
| | | | - Riemer H J A Slart
- Medical Imaging Center, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, The Netherlands
- TechMed Centre, Department of Biomedical Photonic Imaging, University of Twente, Enschede, The Netherlands
| | - Panagiotis Georgoulias
- Department of Nuclear Medicine, University of Thessaly, University Hospital of Larissa, Larissa, Greece
| | - Christoph Rischpler
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Mark Lubberink
- Department of Medical Physics and PET Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Roberto Sciagra
- Nuclear Medicine Unit, Department of Experimental and Clinical Biomedical Sciences, University of Florence, Florence, Italy
| | - Jan Bucerius
- Department of Nuclear Medicine, Maastricht University Medical Center and Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
- Department of Nuclear Medicine, University Hospital RWTH Aachen, Aachen, Germany
| | - Denis Agostini
- Department of Nuclear Medicine, CHU Caen Normandy University, Caen, France
| | - Hein J Verberne
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
12
|
Comparative Cardiac Phantom Study Using Tc-99m/I-123 and Tl-201/I-123 Tracers with Cadmium-Zinc-Telluride Detector-Based Single-Photon Emission Computed Tomography. Nucl Med Mol Imaging 2019; 53:57-63. [PMID: 30828402 DOI: 10.1007/s13139-018-0559-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 11/08/2018] [Accepted: 12/04/2018] [Indexed: 12/25/2022] Open
Abstract
Objective A recently introduced single-photon emission computed tomography (SPECT), based on cadmium-zinc-telluride (CZT) detectors (D-SPECT), supports high energy resolution for cardiac imaging. Importantly, the high energy resolution may allow simultaneous dual-isotope (SDI) imaging (e.g., using Tc-99m and I-123). We quantitatively evaluated Tc-99m/I-123 SDI imaging by D-SPECT in comparison with conventional T1-201/I-123. Materials and Methods Energy resolution was measured as a percentage of the full width at half maximum (FWHM) for Tc-99m, I-123, and Tl-201. The impact of cross-talk and reconstructed image contrast were quantified by measuring the contrast-to-noise ratio (CNR), and the transmural defect contrast in the left ventricle wall (C TD) induced by a difference in energy, for combinations of Tc-99m/I-123 or Tl-201/I-123, using an RH-2 cardiac phantom. Corresponding measurement was also carried out in Anger SPECT (A-SPECT). Results The energy resolution of the D-SPECT system was 5.4%/5.1% for Tc-99m/I-123 and 5.4%/5.3% for Tl-201/I-123, which was approximately two times higher than the A-SPECT. No notable difference was confirmed in the CNRs of the two systems, but T1-201/I-123 showed overall higher value than Tc-99m/I-123. Compared to A-SPECT, C TD of D-SPECT significantly increased with both Tc-99m/I-123 and T1-201/I-123 (p < 0.05). In DSPECT, the combination of Tc-99m/I-123 had a slightly better C TD than T1-201/I-123. In addition, C TD of Tc-99m/I-123 was improved with scatter correction at both nuclides (p < 0.05), but in Tl-201/I-123, no significant improvement was confirmed in I-123 (p > 0.05). Conclusion D-SPECT was considered to be capable of performing high-quality SDI imaging using Tc-99m/I-123.
Collapse
|
13
|
Zhang YQ, Jiang YF, Hong L, Chen M, Zhang NN, Yang HJ, Zhou YF. Diagnostic value of cadmium-zinc-telluride myocardial perfusion imaging versus coronary angiography in coronary artery disease: A PRISMA-compliant meta-analysis. Medicine (Baltimore) 2019; 98:e14716. [PMID: 30817614 PMCID: PMC6831125 DOI: 10.1097/md.0000000000014716] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Rapid progress has been made in research of cadmium-zinc-telluride (CZT) technology in the last few years, which might serve as a new method to diagnose coronary artery disease. However, compared with coronary angiography, the diagnostic value of CZT is still controversial. We aimed to evaluate diagnosis value of coronary angiography versus CZT in coronary artery disease. METHODS We searched the database for eligible researches associated with CZT- myocardial perfusion imaging (MPI) and invasive coronary angiography, extracted the relevant data, and rigorously screened it according to the inclusion and exclusion criteria. The accuracy indicators included sensitivity, specificity, accuracy, positive and negative likelihood ratios. RESULTS According to the inclusion and exclusion criteria, we finally found 20 studies containing 2350 patients in this search. Pooled results showed that sensitivity of CZT-MPI was 0.84% and 95% confidence interval (95% CI): 0.78 to 0.89, specificity was 0.72, 95% CI (0.62-0.76), the specificity was lower apparently. The positive likelihood ratio was 3.0, 95% CI (2.4-3.8), the negative likelihood ratio was 0.22, 95% CI (0.16-0.31), diagnostic odds ratio was 14, 95% CI (7.84-17.42). CONCLUSION This meta-analysis showed that CZT-MPI had satisfactory sensitivity and specificity for diagnosing coronary artery disease. Larger studies are required for further evaluation.
Collapse
|
14
|
Imbert L, Roch V, Merlin C, Djaballah W, Cachin F, Perrin M, Claudin M, Verger A, Boutley H, Karcher G, Marie PY. Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol. J Nucl Cardiol 2018; 25:2016-2023. [PMID: 28512723 DOI: 10.1007/s12350-017-0914-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 03/28/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE OF THE REPORT This study aimed at assessing an original low-dose dual-isotope procedure in which the abnormal stress Tc-99m Sestamibi SPECT is followed by rest Tl-201 SPECT, along with a head-to-head comparison with a single-isotope procedure. METHODS AND RESULTS One hundred two patients, referred for a low-dose stress-SPECT with Sestamibi (123 ± 20 MBq) on a CZT camera and for whom a rest Sestamibi SPECT was warranted, had an additional Tl-201 rest-SPECT (52 ± 5 MBq) between stress and rest Sestamibi SPECT recordings. Tl-201 images were processed for spill-over and scatter corrections, and uptake differences with stress Sestamibi SPECT were analyzed: (1) for rest acquisitions from Tl-201 (dual-isotope procedure) and from Sestamibi (single-isotope procedure) and (2) in segments for which a diagnosis of ischemia, infarct, or normal perfusion was achieved. Mean effective dose was 8.3 mSv for dual-isotope but would decrease to 5.7 mSv for an expected rate of 37% of patients for whom rest-SPECT is not warranted. After a further background correction of Tl-201 images, the rest-stress difference in myocardial uptake was equivalent between dual- and single-procedures for identifying ischemic segments (respective areas-under-curves: 0.83 ± 0.03 and 0.81 ± 0.03). CONCLUSION This original dual-isotope procedure provides acceptable radiation doses and consistent results, as compared with conventional single-isotope.
Collapse
Affiliation(s)
- Laetitia Imbert
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France.
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France.
- INSERM, Université de Lorraine, UMR 947, IADI, 54000, Nancy, France.
- Department of Radiotherapy, Lorraine Cancerology Institute, 54500, Vandoeuvre, France.
| | - Véronique Roch
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
| | - Charles Merlin
- Department of Nuclear Medicine, Jean Perrin Centre, Université d'Auvergne, 63011, Clermont-Ferrand, France
- INSERM, Université d'Auvergne, UMR 990, IMTV, 63000, Clermont-Ferrand, France
| | - Wassila Djaballah
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
| | - Florent Cachin
- Department of Nuclear Medicine, Jean Perrin Centre, Université d'Auvergne, 63011, Clermont-Ferrand, France
- INSERM, Université d'Auvergne, UMR 990, IMTV, 63000, Clermont-Ferrand, France
| | - Mathieu Perrin
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
| | - Marine Claudin
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
| | - Antoine Verger
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
- INSERM, Université de Lorraine, UMR 947, IADI, 54000, Nancy, France
| | - Henri Boutley
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
- University of Lorraine, Faculty of Medicine, 54000, Nancy, France
| | - Gilles Karcher
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
- University of Lorraine, Faculty of Medicine, 54000, Nancy, France
| | - Pierre-Yves Marie
- CHRU-Nancy, Université de Lorraine, Department of Nuclear Medicine, 54000, Nancy, France
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
- INSERM, Université de Lorraine, UMR 1116, DCAC, 54000, Nancy, France
| |
Collapse
|
15
|
Sharir T, Slomka P. Dual-isotope myocardial perfusion SPECT imaging: Past, present, and future. J Nucl Cardiol 2018; 25:2024-2028. [PMID: 28664393 DOI: 10.1007/s12350-017-0966-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Accepted: 06/15/2017] [Indexed: 10/19/2022]
Affiliation(s)
- Tali Sharir
- Department of Nuclear Cardiology, Assuta Medical Center, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel.
- Faculty of Health Sciences, Ben Gurion University of the Negev, Beer Sheba, Israel.
| | - Piotr Slomka
- Department of Imaging (Division of Nuclear Medicine) and Medicine, Cedars Sinai Medical Center, Los Angeles, CA, USA
- David Geffen School of Medicine at the UCLA, Los Angeles, CA, USA
| |
Collapse
|
16
|
Dorbala S, Ananthasubramaniam K, Armstrong IS, Chareonthaitawee P, DePuey EG, Einstein AJ, Gropler RJ, Holly TA, Mahmarian JJ, Park MA, Polk DM, Russell R, Slomka PJ, Thompson RC, Wells RG. Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation. J Nucl Cardiol 2018; 25:1784-1846. [PMID: 29802599 DOI: 10.1007/s12350-018-1283-y] [Citation(s) in RCA: 225] [Impact Index Per Article: 32.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Sharmila Dorbala
- Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | | | | | | | | | - Andrew J Einstein
- Columbia University Medical Center and New York-Presbyterian Hospital, New York, NY, USA
| | | | - Thomas A Holly
- Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - John J Mahmarian
- Houston Methodist Hospital and Weill Cornell Medical College, Houston, TX, USA
| | | | - Donna M Polk
- Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | | | | | | | - R Glenn Wells
- University of Ottawa Heart Institute, Ottawa, Canada
| |
Collapse
|
17
|
Goshen E, Beilin L, Stern E, Kenig T, Goldkorn R, Ben-Haim S. Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results. EJNMMI Phys 2018. [PMID: 29536291 PMCID: PMC5849748 DOI: 10.1186/s40658-018-0205-z] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Background The performance of a prototype novel digital single-photon emission computed tomography (SPECT) camera with multiple pixelated CZT detectors and high sensitivity collimators (Digital SPECT; Valiance X12 prototype, Molecular Dynamics) was evaluated in various clinical settings. Images obtained in the prototype system were compared to images from an analog camera fitted with high-resolution collimators. Clinical feasibility, image quality, and diagnostic performance of the prototype were evaluated in 36 SPECT studies in 35 patients including bone (n = 21), brain (n = 5), lung perfusion (n = 3), and parathyroid (n = 3) and one study each of sentinel node and labeled white blood cells. Images were graded on a scale of 1–4 for sharpness, contrast, overall quality, and diagnostic confidence. Results Digital CZT SPECT provided a statistically significant improvement in sharpness and contrast in clinical cases (mean score of 3.79 ± 0.61 vs. 3.26 ± 0.50 and 3.92 ± 0.29 vs. 3.34 ± 0.47 respectively, p < 0.001 for both). Overall image quality was slightly higher for the digital SPECT but not statistically significant (3.74 vs. 3.66). Conclusion CZT SPECT provided significantly improved image sharpness and contrast compared to the analog system in the clinical settings evaluated. Further studies will evaluate the diagnostic performance of the system in large patient cohorts in additional clinical settings.
Collapse
Affiliation(s)
- Elinor Goshen
- Department of Nuclear Medicine, Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan, Israel. .,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | | | - Eli Stern
- Molecular Dynamics, Hamilton, Bermuda
| | - Tal Kenig
- Molecular Dynamics, Hamilton, Bermuda
| | - Ronen Goldkorn
- Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.,Department of Nuclear Cardiology, Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan, Israel
| | - Simona Ben-Haim
- Department of Nuclear Medicine, Chaim Sheba Medical Center, Tel Hashomer, Ramat Gan, Israel.,Institute of Nuclear Medicine, University College London and UCL Hospitals, London, UK
| |
Collapse
|
18
|
Caobelli F, Wollenweber T, Bavendiek U, Kühn C, Schütze C, Geworski L, Thackeray JT, Bauersachs J, Haverich A, Bengel FM. Simultaneous dual-isotope solid-state detector SPECT for improved tracking of white blood cells in suspected endocarditis. Eur Heart J 2018; 38:436-443. [PMID: 27469371 DOI: 10.1093/eurheartj/ehw231] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Accepted: 04/29/2016] [Indexed: 11/13/2022] Open
Abstract
Aims High-energy resolution and sensitivity of novel cadmium-zinc-telluride (CZT) detector equipped SPECT systems facilitate simultaneous imaging of multiple isotopes and may enhance the detection of molecular/cellular signals. This may refine the detection of endocarditis. This study was designed to determine the feasibility and diagnostic accuracy of simultaneous imaging of inflammation with 111In-labeled white blood cells (WBCs) and myocardial perfusion with 99mTc-sestamibi, for localization of WBCs relative to the valve plane in suspected endocarditis. Methods and results A dedicated cardiac CZT camera (Discovery 530c, GE Healthcare) was employed. Anthropomorphic thorax phantom studies were followed by clinical studies in 34 patients with suspected infection of native valves (n = 12) or implants (n = 22). Simultaneous 111In-WBC/99mTc perfusion imaging was performed, and compared with standard 111In-WBC planar scintigraphy and SPECT-CT. Phantom studies ruled out significant radioisotope crosstalk. Downscatter on 99mTc images was not observed for 111In activity as high as 2.5*99mTc activity. In patients, image quality was superior for CZT imaging vs. conventional SPECT-CT and planar scintigraphy (P < 0.01). Cadmium-zinc-telluride dual isotope imaging improved reader confidence for detection of inflammatory foci. Diagnostic accuracy based on surgery or Duke Criteria during follow-up was highest for CZT imaging (P < 0.001). Conclusion Novel CZT SPECT technology improves the accuracy of molecular/cellular cardiac imaging. Simultaneous multi-isotope imaging with 111In and 99mTc is feasible and aids in the workup of suspected endocarditis.
Collapse
Affiliation(s)
- Federico Caobelli
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| | - Tim Wollenweber
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| | - Udo Bavendiek
- Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany
| | - Christian Kühn
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Christian Schütze
- Department of Radiation Protection and Medical Physics, Hannover Medical School, Hannover, Germany
| | - Lilli Geworski
- Department of Radiation Protection and Medical Physics, Hannover Medical School, Hannover, Germany
| | - James T Thackeray
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| | - Johann Bauersachs
- Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany
| | - Axel Haverich
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Frank M Bengel
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| |
Collapse
|
19
|
Issue “noninvasive molecular imaging and theranostic probes”: New concepts in myocardial imaging. Methods 2017; 130:72-78. [DOI: 10.1016/j.ymeth.2017.05.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2017] [Accepted: 05/29/2017] [Indexed: 01/16/2023] Open
|
20
|
D'estanque E, Hedon C, Lattuca B, Bourdon A, Benkiran M, Verd A, Roubille F, Mariano-Goulart D. Optimization of a simultaneous dual-isotope 201Tl/ 123I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary? J Nucl Cardiol 2017; 24:1361-1369. [PMID: 27225516 DOI: 10.1007/s12350-016-0524-1] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Accepted: 04/11/2016] [Indexed: 01/08/2023]
Abstract
BACKGROUND Dual-isotope 201Tl/123I-MIBG SPECT can assess trigger zones (dysfunctions in the autonomic nervous system located in areas of viable myocardium) that are substrate for ventricular arrhythmias after STEMI. This study evaluated the necessity of delayed acquisition and scatter correction for dual-isotope 201Tl/123I-MIBG SPECT studies with a CZT camera to identify trigger zones after revascularization in patients with STEMI in routine clinical settings. METHODS Sixty-nine patients were prospectively enrolled after revascularization to undergo 201Tl/123I-MIBG SPECT using a CZT camera (Discovery NM 530c, GE). The first acquisition was a single thallium study (before MIBG administration); the second and the third were early and late dual-isotope studies. We compared the scatter-uncorrected and scatter-corrected (TEW method) thallium studies with the results of magnetic resonance imaging or transthoracic echography (reference standard) to diagnose myocardial necrosis. RESULTS Summed rest scores (SRS) were significantly higher in the delayed MIBG studies than the early MIBG studies. SRS and necrosis surface were significantly higher in the delayed thallium studies with scatter correction than without scatter correction, leading to less trigger zone diagnosis for the scatter-corrected studies. Compared with the scatter-uncorrected studies, the late thallium scatter-corrected studies provided the best diagnostic values for myocardial necrosis assessment. CONCLUSIONS Delayed acquisitions and scatter-corrected dual-isotope 201Tl/123I-MIBG SPECT acquisitions provide an improved evaluation of trigger zones in routine clinical settings after revascularization for STEMI.
Collapse
Affiliation(s)
- Emmanuel D'estanque
- Nuclear Medicine Department, Montpellier University Hospital, 371, Avenue du Doyen Gaston Giraud, 34295, Montpellier Cedex 5, France.
| | - Christophe Hedon
- Cardiology Department, Montpellier University Hospital, Montpellier, France
- U1046 INSERM, UMR9214 CNRS, Montpellier University Hospital, Montpellier, France
| | - Benoît Lattuca
- Cardiology Department, Montpellier University Hospital, Montpellier, France
| | - Aurélie Bourdon
- Nuclear Medicine Department, Montpellier University Hospital, 371, Avenue du Doyen Gaston Giraud, 34295, Montpellier Cedex 5, France
| | - Meriem Benkiran
- Nuclear Medicine Department, Montpellier University Hospital, 371, Avenue du Doyen Gaston Giraud, 34295, Montpellier Cedex 5, France
| | - Aurélie Verd
- Nuclear Medicine Department, Montpellier University Hospital, 371, Avenue du Doyen Gaston Giraud, 34295, Montpellier Cedex 5, France
| | - François Roubille
- Cardiology Department, Montpellier University Hospital, Montpellier, France
- U1046 INSERM, UMR9214 CNRS, Montpellier University Hospital, Montpellier, France
| | - Denis Mariano-Goulart
- Nuclear Medicine Department, Montpellier University Hospital, 371, Avenue du Doyen Gaston Giraud, 34295, Montpellier Cedex 5, France
- U1046 INSERM, UMR9214 CNRS, Montpellier University Hospital, Montpellier, France
| |
Collapse
|
21
|
Assante R, Acampa W. Dual isotope and multidetector camera: The best choices for a specific end-point. J Nucl Cardiol 2017; 24:1370-1373. [PMID: 27197817 DOI: 10.1007/s12350-016-0520-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Accepted: 04/12/2016] [Indexed: 01/08/2023]
Affiliation(s)
- Roberta Assante
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Wanda Acampa
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy.
- Institute of Biostructure and Bioimaging, National Council of Research, Naples, Italy.
| |
Collapse
|
22
|
Nudi F, Iskandrian AE, Schillaci O, Peruzzi M, Frati G, Biondi-Zoccai G. Diagnostic Accuracy of Myocardial Perfusion Imaging With CZT Technology: Systemic Review and Meta-Analysis of Comparison With Invasive Coronary Angiography. JACC Cardiovasc Imaging 2017; 10:787-794. [PMID: 28330657 DOI: 10.1016/j.jcmg.2016.10.023] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 09/29/2016] [Accepted: 10/05/2016] [Indexed: 02/08/2023]
Abstract
OBJECTIVES This study sought to summarize the evidence on stress myocardial perfusion imaging (MPI) using cadmium-zinc-telluride (CZT) technology for the diagnosis of obstructive coronary artery disease (CAD). The CZT cameras are newly introduced, and comparative data with the conventional Anger technology (Anger-MPI) are lacking. BACKGROUND The diagnostic accuracy of Anger-MPI for detection of angiographically significant CAD is well established; however, less evidence is available on the diagnostic accuracy of CZT-MPI. METHODS Clinical studies comparing CZT-MPI and invasive coronary angiography were systematically searched and abstracted. Calculations of diagnostic accuracy, including sensitivity, specificity, likelihood ratios, and diagnostic odds ratio, were obtained with fixed and random effects, reporting point estimates and 95% confidence intervals. RESULTS Based on our search, a total of 16 studies (N = 2,092) were included. The sensitivity of CZT-MPI was 0.84 (95% confidence interval [CI]: 0.78 to 0.89), whereas the specificity of 0.69 (95% CI: 0.62 to 0.76) was significantly reduced. The positive likelihood ratio was 2.73 (95% CI: 2.21 to 3.39), the negative likelihood ratio was 0.24 (95% CI: 0.17 to 0.31), and the diagnostic odds ratio was 11.93 (95% CI: 7.84 to 17.42). At subgroup and meta-regression analyses, the diagnostic accuracy between D-SPECT and Discovery cameras was similar (p = 0.711) and not impacted upon by smaller sample size studies (p = 0.573). CONCLUSIONS CZT-MPI has satisfactory sensitivity for angiographically significant CAD, but its suboptimal specificity warrants further development and research.
Collapse
Affiliation(s)
- Francesco Nudi
- Service of Hybrid Cardio Imaging, Madonna della Fiducia Clinic, Rome, Italy; Ostia Radiologica, Ostia, Italy; Etisan, Rome, Italy
| | - Ami E Iskandrian
- Division of Cardiovascular Disease, University of Alabama at Birmingham, Alabama
| | - Orazio Schillaci
- Department of Nuclear Medicine, Tor Vergata University, Rome, Italy
| | - Mariangela Peruzzi
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy
| | - Giacomo Frati
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Department of AngioCardioNeurology, IRCCS Neuromed, Pozzilli, Italy
| | - Giuseppe Biondi-Zoccai
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Department of AngioCardioNeurology, IRCCS Neuromed, Pozzilli, Italy.
| |
Collapse
|
23
|
Ishihara M, Onoguchi M, Taniguchi Y, Shibutani T. Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities. Int J Cardiovasc Imaging 2017; 33:2057-2066. [PMID: 28664481 DOI: 10.1007/s10554-017-1205-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Accepted: 06/22/2017] [Indexed: 02/02/2023]
Abstract
The aim of this study was to clarify the differences in thallium-201-chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium-zinc-telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.
Collapse
Affiliation(s)
- Masaru Ishihara
- Department of Radiology, Hyogo Cancer Center, 13-70 Kitaoji, Akashi, Hyogo, 673-8558, Japan.,Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.
| | - Yasuyo Taniguchi
- Department of Cardiology, Hyogo Brain and Heart Center at Himeji, 520 Saisho-ko, Himeji, Hyogo, 670-0981, Japan
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
| |
Collapse
|
24
|
Phillips LM. CZT-SPECT: Reaching its Potential. JACC Cardiovasc Imaging 2017; 10:795-796. [DOI: 10.1016/j.jcmg.2017.02.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Revised: 02/10/2017] [Accepted: 02/15/2017] [Indexed: 11/28/2022]
|
25
|
Fukuchi T, Okauchi T, Shigeta M, Yamamoto S, Watanabe Y, Enomoto S. Positron emission tomography with additional γ
-ray detectors for multiple-tracer imaging. Med Phys 2017; 44:2257-2266. [DOI: 10.1002/mp.12149] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 01/27/2017] [Accepted: 01/29/2017] [Indexed: 11/10/2022] Open
Affiliation(s)
| | - Takashi Okauchi
- RIKEN Center for Life Science Technologies; Kobe 650-0047 Japan
| | - Mika Shigeta
- RIKEN Center for Life Science Technologies; Kobe 650-0047 Japan
| | - Seiichi Yamamoto
- Department of Radiological and Medical Laboratory Sciences; Nagoya University Graduate School of Medicine; Nagoya 461-0047 Japan
| | | | - Shuichi Enomoto
- RIKEN Center for Life Science Technologies; Kobe 650-0047 Japan
| |
Collapse
|
26
|
Angelidis G, Giamouzis G, Karagiannis G, Butler J, Tsougos I, Valotassiou V, Giannakoulas G, Dimakopoulos N, Xanthopoulos A, Skoularigis J, Triposkiadis F, Georgoulias P. SPECT and PET in ischemic heart failure. Heart Fail Rev 2017; 22:243-261. [DOI: 10.1007/s10741-017-9594-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
27
|
Slomka P, Hung GU, Germano G, Berman DS. Novel SPECT Technologies and Approaches in Cardiac Imaging. CARDIOVASCULAR INNOVATIONS AND APPLICATIONS 2016; 2:31-46. [PMID: 29034066 PMCID: PMC5640436 DOI: 10.15212/cvia.2016.0052] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Recent novel approaches in myocardial perfusion single photon emission CT (SPECT) have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv) stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.
Collapse
Affiliation(s)
- Piotr Slomka
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Guang-Uei Hung
- Department of Nuclear Medicine, Chang Bing Show Chwan Memorial Hospital, Changhua, Taiwan
| | - Guido Germano
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Daniel S. Berman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| |
Collapse
|
28
|
Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM). Eur J Nucl Med Mol Imaging 2016; 43:2423-2432. [PMID: 27542010 DOI: 10.1007/s00259-016-3467-5] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2016] [Accepted: 07/11/2016] [Indexed: 10/21/2022]
Abstract
The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.
Collapse
|
29
|
Imbert L, Marie PY. CZT cameras: A technological jump for myocardial perfusion SPECT. J Nucl Cardiol 2016; 23:894-6. [PMID: 26108415 DOI: 10.1007/s12350-015-0216-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Accepted: 06/10/2015] [Indexed: 11/28/2022]
Affiliation(s)
- Laetitia Imbert
- CRAN, UMR 7039, Université de Lorraine - CNRS, 54500, Vandoeuvre, France.
- Department of Radiotherapy, Institut de Cancérologie de Lorraine, 54500, Vandoeuvre, France.
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France.
- Department of Nuclear Medicine, CHU Nancy, 54000, Nancy, France.
| | - Pierre-Yves Marie
- Nancyclotep Experimental Imaging Platform, 54000, Nancy, France
- Department of Nuclear Medicine, CHU Nancy, 54000, Nancy, France
- Faculty of Medicine, University of Lorraine, 54000, Nancy, France
- INSERM, U1116, 54000, Nancy, France
| |
Collapse
|
30
|
Henzlova MJ, Duvall WL. Which SPECT for today, which SPECT for tomorrow? J Nucl Cardiol 2016; 23:803-6. [PMID: 27072000 DOI: 10.1007/s12350-016-0496-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Accepted: 03/29/2016] [Indexed: 11/26/2022]
|
31
|
Guo Z, Gao M, Zhang D, Li Y, Song M, Zhuang R, Su X, Chen G, Liu T, Liu P, Wu H, Du J, Zhang X. Simultaneous SPECT imaging of multi-targets to assist in identifying hepatic lesions. Sci Rep 2016; 6:28812. [PMID: 27377130 PMCID: PMC4932524 DOI: 10.1038/srep28812] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Accepted: 06/08/2016] [Indexed: 12/11/2022] Open
Abstract
Molecular imaging technique is an attractive tool to detect liver disease at early stage. This study aims to develop a simultaneous dual-isotope single photon emission computed tomography (SPECT)/CT imaging method to assist diagnosis of hepatic tumor and liver fibrosis. Animal models of liver fibrosis and orthotopic human hepatocellular carcinoma (HCC) were established. The tracers of 131I-NGA and 99mTc-3P-RGD2 were selected to target asialoglycoprotein receptor (ASGPR) on the hepatocytes and integrin αvβ3 receptor in tumor or fibrotic liver, respectively. SPECT imaging and biodistribution study were carried out to verify the feasibility and superiority. As expected, 99mTc-3P-RGD2 had the ability to evaluate liver fibrosis and detect tumor lesions. 131I-NGA showed that it was effective in assessing the anatomy and function of the liver. In synchronized dual-isotope SPECT/CT imaging, clear fusion images can be got within 30 minutes for diagnosing liver fibrosis and liver cancer. This new developed imaging approach enables the acquisition of different physiological information for diagnosing liver fibrosis, liver cancer and evaluating residual functional liver volume simultaneously. So synchronized dual-isotope SPECT/CT imaging with 99mTc-3P-RGD2 and 131I-NGA is an effective approach to detect liver disease, especially liver fibrosis and liver cancer.
Collapse
Affiliation(s)
- Zhide Guo
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China.,Department of Isotope, China Institute of Atomic Energy, P. O. Box 2108, Beijing 102413, China
| | - Mengna Gao
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China
| | - Deliang Zhang
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China
| | - Yesen Li
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China.,The First Affiliated Hospital of Xiamen University, Zhenhai road, Xiamen 361103, China
| | - Manli Song
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China
| | - Rongqiang Zhuang
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China
| | - Xinhui Su
- Zhongshan Hospital Affiliated of Xiamen University, Hubin South Road, Xiamen 361004, China
| | - Guibing Chen
- The First Affiliated Hospital of Xiamen University, Zhenhai road, Xiamen 361103, China
| | - Ting Liu
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China
| | - Pingguo Liu
- Zhongshan Hospital Affiliated of Xiamen University, Hubin South Road, Xiamen 361004, China
| | - Hua Wu
- The First Affiliated Hospital of Xiamen University, Zhenhai road, Xiamen 361103, China
| | - Jin Du
- Department of Isotope, China Institute of Atomic Energy, P. O. Box 2108, Beijing 102413, China
| | - Xianzhong Zhang
- Center for Molecular Imaging and Translational Medicine, State Key Laboratory of Molecular Vaccinology and Molecular Diagnostics, School of Public Health, Xiamen University, Xiang'an South Rd, Xiamen 361102, China
| |
Collapse
|
32
|
Ben-Haim S, Kennedy J, Keidar Z. Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging—Technological Aspects and Clinical Applications. Semin Nucl Med 2016; 46:273-85. [DOI: 10.1053/j.semnuclmed.2016.01.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
33
|
Allie R, Hutton BF, Prvulovich E, Bomanji J, Michopoulou S, Ben-Haim S. Pitfalls and artifacts using the D-SPECT dedicated cardiac camera. J Nucl Cardiol 2016; 23:301-10. [PMID: 26403143 DOI: 10.1007/s12350-015-0277-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Accepted: 07/28/2015] [Indexed: 11/28/2022]
Abstract
Myocardial perfusion imaging is a well-established and widely used imaging technique for the assessment of patients with known or suspected coronary artery disease. Pitfalls and artifacts associated with conventional gamma cameras are well known, and the ways to avoid and correct them have been described. In recent years solid-state detector dedicated cardiac cameras were introduced and have been shown to offer improved accuracy in addition to new imaging protocols and novel applications. The purpose of this manuscript is to familiarize the readers with the causes and effects of technical, patient-related, and operator-related pitfalls and artifacts associated with the D-SPECT dedicated cardiac camera with solid-state detectors. The manuscript offers guidance on how to avoid these factors, how to detect them, and how to correct better for them, providing high-quality diagnostic images.
Collapse
Affiliation(s)
- Rayjanah Allie
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Brian F Hutton
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| | - Elizabeth Prvulovich
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Jamshed Bomanji
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Sofia Michopoulou
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Simona Ben-Haim
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom.
- Institute of Nuclear Medicine, Chaim Sheba Medical Center, Tel-Hashomer, 5265601, Israel.
| |
Collapse
|
34
|
Schatka I, Weiberg D, Reichelt S, Owsianski-Hille N, Derlin T, Berding G, Bengel FM. A randomized, double-blind, crossover comparison of novel continuous bed motion versus traditional bed position whole-body PET/CT imaging. Eur J Nucl Med Mol Imaging 2015; 43:711-7. [DOI: 10.1007/s00259-015-3226-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Accepted: 10/08/2015] [Indexed: 11/29/2022]
|
35
|
Henzlova MJ, Duvall WL. Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast…. J Nucl Cardiol 2015; 22:523-5. [PMID: 25423933 DOI: 10.1007/s12350-014-0034-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
36
|
Pourmoghaddas A, Vanderwerf K, Ruddy TD, Glenn Wells R. Scatter correction improves concordance in SPECT MPI with a dedicated cardiac SPECT solid-state camera. J Nucl Cardiol 2015; 22:334-43. [PMID: 25342215 DOI: 10.1007/s12350-014-0008-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Accepted: 09/12/2014] [Indexed: 01/20/2023]
Abstract
PURPOSE Correction for photon attenuation and scatter improves image quality with conventional NaI-based gamma cameras but evaluation of these corrections for novel solid-state dedicated cardiac cameras is limited. In this study, we assess the accuracy of dual-energy-window (DEW) scatter correction (SC) applied to clinically acquired (99m)Tc-tetrofosmin myocardial perfusion images obtained on a dedicated multi-pinhole camera with cadmium-zinc-telluride (CZT) detectors (GE Discovery NM530) compared to DEW scatter-corrected images from our conventional SPECT camera (GE Infinia Hawkeye 4; INF). METHODS A modified DEW SC method was formulated to account for the detection of primary photons in the lower energy window (120 keV ± 5%) with CZT detectors, in addition to estimating the scattered photons detected in the photopeak window (140 keV ± 10%). Phantom experiments were used to estimate the DEW correction parameters. Data from 108 patients, acquired using a standard rest/stress Tc-99m-tetrofosmin SPECT/CT protocol on both cameras, were reconstructed with no correction (NC), attenuation correction (AC), and AC with DEW-SC. Images were compared based on the summed stress/rest/difference scores (SSS/SRS/SDS) calculated by clinical software. RESULTS The correlation between SSS/SRS for the two cameras was excellent (r ≥ 0.94). The mean difference between cameras was <0.4 for SSS/SRS/SDS scores. Since datasets did not follow a normal distribution, non-parametric tests were used to show significant differences between datasets. Classification of disease (SSS) was highly correlated, as ranked by the two cameras (kendall's tau = 0.72, P < .001). AC significantly reduced the mean difference between the two cameras for SSS/SRS compared to NC. AC without SC on the CZT introduced a bias towards higher scores when compared to the INF, which was reduced after applying SC. Although SC increased noise, the scores for the AC/SC images were not significantly different between the two cameras (P > .1). CONCLUSIONS DEW-SC on the CZT camera was feasible and produced images that are not significantly different from those acquired on the INF camera. Although use of SC on CZT images does increase noise, the resultant noise does not introduce bias relative to the INF camera.
Collapse
|
37
|
Seco J, Clasie B, Partridge M. Review on the characteristics of radiation detectors for dosimetry and imaging. Phys Med Biol 2014; 59:R303-47. [PMID: 25229250 DOI: 10.1088/0031-9155/59/20/r303] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been transformed by the implementation of multi-slice CT and digital x-ray imaging systems, with silver halide films now largely obsolete for many applications. Nuclear medicine has benefited from more sensitive, faster and higher-resolution detectors delivering ever-higher SPECT and PET image quality. PET/MR systems have been enabled by the development of gamma ray detectors that can operate in high magnetic fields. These huge advances in imaging have enabled equally impressive steps forward in radiotherapy delivery accuracy, with 4DCT, PET and MRI routinely used in treatment planning and online image guidance provided by cone-beam CT. The challenge of ensuring safe, accurate and precise delivery of highly complex radiation fields has also both driven and benefited from advances in radiation detectors. Detector systems have been developed for the measurement of electron, intensity-modulated and modulated arc x-ray, proton and ion beams, and around brachytherapy sources based on a very wide range of technologies. The types of measurement performed are equally wide, encompassing commissioning and quality assurance, reference dosimetry, in vivo dosimetry and personal and environmental monitoring. In this article, we briefly introduce the general physical characteristics and properties that are commonly used to describe the behaviour and performance of both discrete and imaging detectors. The physical principles of operation of calorimeters; ionization and charge detectors; semiconductor, luminescent, scintillating and chemical detectors; and radiochromic and radiographic films are then reviewed and their principle applications discussed. Finally, a general discussion of the application of detectors for x-ray nuclear medicine and ion beam imaging and dosimetry is presented.
Collapse
Affiliation(s)
- Joao Seco
- Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | | | | |
Collapse
|
38
|
Simulation study on a stationary data acquisition SPECT system with multi-pinhole collimators attached to a triple-head gamma camera system. Ann Nucl Med 2014; 28:716-24. [DOI: 10.1007/s12149-014-0865-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Accepted: 05/21/2014] [Indexed: 10/25/2022]
|
39
|
Du Y, Bhattacharya M, Frey EC. Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator. Phys Med Biol 2014; 59:2813-28. [PMID: 24819280 PMCID: PMC4142679 DOI: 10.1088/0031-9155/59/11/2813] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter modeling can be applied to non-parallel-beam projection geometries.
Collapse
Affiliation(s)
- Yong Du
- Department of Radiology, Johns Hopkins University, 601 N Caroline Street, JOHC 4263, Baltimore, MD 21287, USA
| | | | | |
Collapse
|
40
|
Cervo M, Gerbaudo VH, Park MA, Moore SC. Quantitative simultaneous 111In∕99mTc SPECT-CT of osteomyelitis. Med Phys 2014; 40:082501. [PMID: 23927346 DOI: 10.1118/1.4812421] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE A well-established approach for diagnostic imaging of osteomyelitis (OM), a bone infection, is simultaneous SPECT-CT of 99mTc sulfur colloid (SC) and 111In white blood cells (WBC). This method provides essentially perfect spatial registration of the tracers within anatomic sites of interest. Currently, diagnosis is based purely on a visual assessment-where relative discordance between 99mTc and 111In uptake in bone, i.e., high 111In and low 99mTc, suggests OM. To achieve more quantitative images, noise, scatter, and crosstalk between radionuclides must be addressed through reconstruction. Here the authors compare their Monte Carlo-based joint OSEM (MC-JOSEM) algorithm, which reconstructs both radionuclides simultaneously, to a more conventional triple-energy window-based reconstruction (TEW-OSEM), and to iterative reconstruction with no compensation for scatter (NC-OSEM). METHODS The authors created numerical phantoms of the foot and torso. Multiple bone-infection sites were modeled using high-count Monte Carlo simulation. Counts per voxel were then scaled to values appropriate for 111In WBC and 99mTc SC imaging. Ten independent noisy projection image sets were generated by drawing random Poisson deviates from these very low-noise images. Data were reconstructed using the two iterative scatter-compensation methods, TEW-OSEM and MC-JOSEM, as well as the uncorrected method (NC-OSEM). Mean counts in volumes of interest (VOIs) were used to evaluate the bias and precision of each method. Data were also acquired using a phantom, approximately the size of an adult ankle, consisting of regions representing infected and normal bone marrow, within a bone-like attenuator and surrounding soft tissue; each compartment contained a mixture of 111In and 99mTc. Low-noise data were acquired during multiple short scans over 29 h on a Siemens Symbia T6 SPECT-CT with medium-energy collimators. Pure 99mTc and 111In projection datasets were derived by fitting the acquired projections to the sum of 99mTc and 111In contributions, using the known half-lives. Uncontaminated data were scaled and recombined into six datasets with different activity ratios; ten Poisson noise realizations were then generated for each ratio. VOIs in each of the compartments were used to evaluate the bias and precision of each method with respect to reconstructions of uncontaminated datasets. In addition to the simulated and acquired phantom images, the authors reconstructed patient images with MC-JOSEM and TEW-OSEM. Patient reconstructions were assessed qualitatively for lesion contrast, spatial definition, and scatter. RESULTS For all simulated and acquired infection phantoms, the root-mean squared-error of measured 99mTc activity was significantly improved with MC-JOSEM and TEW-OSEM in comparison to NC-OSEM reconstructions. While MC-JOSEM trended toward outperforming TEW-OSEM, the improvement was only found to be significant (p<0.001) for the acquired bone phantom in which a wide range of 111In∕99mTc concentration ratios were tested. In all cases, scatter correction did not significantly improve 111In quantitation. CONCLUSIONS Compensation for scatter and crosstalk is useful for improving quality, bias, and precision of 99mTc activity estimates in simultaneous dual-radionuclide imaging of OM. The use of the more rigorous MC-based estimates provided marginal improvements over TEW. While the phantom results were encouraging, more subjects are needed to evaluate the usefulness of quantitative 111In∕99mTc SPECT-CT in the clinic.
Collapse
Affiliation(s)
- Morgan Cervo
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Brigham and Women's Hospital, 75 Francis Street, Boston, Massachusetts 02115, USA.
| | | | | | | |
Collapse
|
41
|
Abidov A, Germano G, Hachamovitch R, Slomka P, Berman DS. Gated SPECT in assessment of regional and global left ventricular function: an update. J Nucl Cardiol 2013; 20:1118-43; quiz 1144-6. [PMID: 24234974 DOI: 10.1007/s12350-013-9792-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2013] [Accepted: 09/11/2013] [Indexed: 01/31/2023]
Abstract
Gated myocardial perfusion SPECT (GSPECT) is a major clinical tool, widely used for performing myocardial perfusion imaging procedures. In this review, we have presented the fundamentals of GSPECT and the ways in which the functional measurements it provides have contributed to the emergence of myocardial perfusion SPECT in its important role as a major tool of modern cardiac imaging. GSPECT imaging has shown unique capability to provide accurate, reproducible and operator-independent quantitative data regarding myocardial perfusion, global and regional systolic and diastolic function, stress-induced regional wall-motion abnormalities, ancillary markers of severe and extensive disease, left ventricular geometry and mass, as well as the presence and extent of myocardial scar and viability. Adding functional data to perfusion provides an effective means of increasing both diagnostic accuracy and reader's confidence in the interpretation of the results of perfusion scans. Assessment of global and regional LV function has improved the prognostic power of myocardial perfusion SPECT and has been shown in a large registry to add to the perfusion assessment in predicting benefit from revascularization.
Collapse
|
42
|
|
43
|
Wells RG, Marvin B, Kovalski G, Ruddy TD. Planar radionuclide angiography with a dedicated cardiac SPECT camera. J Nucl Cardiol 2013; 20:358-66. [PMID: 23436136 DOI: 10.1007/s12350-013-9674-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2012] [Accepted: 01/08/2013] [Indexed: 11/25/2022]
Abstract
BACKGROUND We compared a dedicated cardiac camera with a traditional system for left ventricular (LV) functional measurements using gated blood-pool imaging. METHODS 24-frame gated planar images were obtained from 48 patients in an LAO orientation for 6M counts/view on a standard gamma camera. Immediately thereafter, 24-frame ECG-gated data were obtained for 8 minutes on a dedicated cardiac SPECT camera. The gated SPECT image volumes were iteratively reconstructed and then transferred offline. In-house software was used to reproject the images into a 24-frame gated planar format. Both the original and the reprojected gated planar datasets were analyzed using semiautomated software to determine ejection fraction (EF), ventricular volume (end diastolic volume, EDV), peak ejection rate (PER), and peak filling rate (PFR). RESULTS The difference in EF values averaged 0.4% ± 4.4%. The correlation in EF was r ≥ 0.94 (P < .01) with a linear regression slope of 0.98. Correlation of the EDV was r ≥ 0.86 (P < .01), but the volumes from the dedicated cardiac camera were smaller (linear regression slope was 0.6). Correlation of PFR and PER were r = 0.91 and r ≥ 0.83, respectively (P < .01 for both). CONCLUSIONS Reprojection of 24-frame gated blood-pool SPECT images is an effective means of obtaining LV functional measurements with a dedicated cardiac SPECT camera using standard 2D-planar analysis tools.
Collapse
Affiliation(s)
- R Glenn Wells
- Cardiology, University of Ottawa, Ottawa, ON, Canada.
| | | | | | | |
Collapse
|
44
|
Harrison SD, Harrison MA, Duvall WL. Stress myocardial perfusion imaging in the emergency department--new techniques for speed and diagnostic accuracy. Curr Cardiol Rev 2013; 8:116-22. [PMID: 22708910 PMCID: PMC3406271 DOI: 10.2174/157340312801784916] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2010] [Revised: 08/20/2011] [Accepted: 09/05/2011] [Indexed: 11/22/2022] Open
Abstract
Emergency room evaluations of patients presenting with chest pain continue to rise, and these evaluations which often include cardiac imaging, are an increasing area of resource utilization in the current health system. Myocardial perfusion imaging from the emergency department remains a vital component of the diagnosis or exclusion of coronary artery disease as the etiology of chest pain. Recent advances in camera technology, and changes to the imaging protocols have allowed MPI to become a more efficient way of providing this diagnostic information. Compared with conventional SPECT, new high-efficiency CZT cameras provide a 3-5 fold increase in photon sensitivity, 1.65-fold improvement in energy resolution and a 1.7-2.5-fold increase in spatial resolution. With stress-only imaging, rest images are eliminated if stress images are normal, as they provide no additional prognostic or diagnostic value and cancelling the rest images would shorten the length of the test which is of particular importance to the ED population. The rapid but accurate triage of patients in an ED CPU is essential to their care, and stress-only imaging and new CZT cameras allow for shorter test time, lower radiation doses and lower costs while demonstrating good clinical outcomes. These changes to nuclear stress testing can allow for faster throughput of patients through the emergency department while providing a safe and efficient evaluation of chest pain.
Collapse
|
45
|
Neill J, Prvulovich EM, Fish MB, Berman DS, Slomka PJ, Sharir T, Martin WH, DiCarli MF, Ziffer JA, Bomanji JB, Shiti D, Ben-Haim S. Initial multicentre experience of high-speed myocardial perfusion imaging: comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation. Eur J Nucl Med Mol Imaging 2013; 40:1084-94. [PMID: 23595108 DOI: 10.1007/s00259-013-2399-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2012] [Accepted: 03/15/2013] [Indexed: 10/27/2022]
Abstract
PURPOSE High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. METHODS The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS ≥3 or coronary territorial SSS ≥2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5% and coronary territorial TPD ≥3% were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; ≥50% was considered significant. RESULTS Of the 50 patients, 13 (26%) had no stenosis, 22 (44%) had single-vessel disease, 6 (12%) had double-vessel disease and 9 (18%) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's ρ 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92% (35/38), 83% (10/12) and 90% (45/50) vs. 84% (32/38), 50% (6/12) and 76% (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89% (31/35), 57% (8/14) and 80% (39/49) vs. 86% (31/36), 77% (10/13) and 84% (41/49), respectively. CONCLUSION HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual assessment better than conventional SPECT. Further assessment in a larger patient population may be needed to confirm this observation.
Collapse
Affiliation(s)
- Johanne Neill
- Institute of Nuclear Medicine, University College London Hospital, 235 Euston Road, London NW1 2BU, UK.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Evaluation of ischaemia in obese patients: feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera. Eur J Nucl Med Mol Imaging 2012; 39:1254-61. [PMID: 22699527 DOI: 10.1007/s00259-012-2161-5] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2012] [Accepted: 05/16/2012] [Indexed: 10/28/2022]
Abstract
PURPOSE Obesity is a significant and independent risk factor for cardiovascular disease, and assessing ischaemia in obese patients is clinically important but sometimes difficult because of imaging artefacts. The aim of this study was to evaluate the feasibility and diagnostic accuracy of stress/rest imaging with a cadmium-zinc telluride (CZT) camera using a low-dose protocol in a series of consecutive obese patients referred for the evaluation of coronary artery disease. METHODS We considered 148 consecutive obese patients (mean BMI 39 ± 7 kg/m(2)) with known or suspected coronary artery disease referred to our laboratory for stress/rest myocardial perfusion imaging. A subgroup of 103 of the 148 patients underwent invasive coronary angiography for clinical reasons. All patients underwent a single-day stress/rest low-dose ultrafast protocol. Patients were injected with (99m)Tc-tetrofosmin at a dose in the range 185-222 MBq during bicycle exercise or dipyridamole stress, and underwent the first scan with an acquisition time of 7 min starting 15 min after the end of the stress. The rest scan with an acquisition time of 6 min was started from 30 to 45 min after (99m)Tc-tetrofosmin injection at a dose in the range 370-444 MBq. Images were visually inspected, and the summed stress score (SSS) and summed rest score (SRS) were obtained. RESULTS Image quality was graded very good or excellent in all patients. Of the 103 patients who underwent coronary angiography, 12 (12 %), 26 (25 %) and 56 (54 %) showed one-, two- and three-vessel disease, and 9 showed normal coronary vessels. In the 103 patients submitted to coronary angiography, the mean SSS and SRS were 7 ± 6 and 2 ± 3, respectively. Semiquantitative regional and global SSS was a good discriminant of coronary artery disease and the area under the overall ROC curve was 0.848 (95 % CI 0.723-0.975). CONCLUSION In obese patients, a single-day stress/rest low-dose ultrafast protocol with a CZT camera is clinically feasible and provides high image quality.
Collapse
|
47
|
DePuey EG. Advances in SPECT camera software and hardware: currently available and new on the horizon. J Nucl Cardiol 2012; 19:551-81; quiz 585. [PMID: 22456968 DOI: 10.1007/s12350-012-9544-7] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
48
|
|
49
|
Abstract
Advances in SPECT and PET imaging hardware, software, and radiotracers are vastly improving the non-invasive evaluation of myocardial perfusion and function. In contrast to traditional dual-headed, sodium iodide crystal and photomultiplier cameras with mechanical collimators, new SPECT camera designs utilize novel, collimators, and solid-state detectors that convert photons directly to electrical signals. These cameras simultaneously collect data from as many as 76 small detectors narrowly focused on the heart. New noise regularization and resolution recovery/noise reduction reconstruction software interprets emitted counts more efficiently and thus more effectively discriminates between useful signals and noise. As a result, shorter acquisition times and/or lower tracer doses produce higher quality SPECT images than were possible before. PET perfusion imaging has benefitted from the introduction of novel detectors that now allow true 3D imaging, new radiopharmaceuticals, and precise attenuation correction (AC). These developments have resulted in perfusion images with higher spatial and contrast resolution that may be acquired in shorter protocols and/or with less patient radiation exposure than traditional SPECT. Hybrid SPECT/CT and PET/CT cameras utilize transmission computed tomographic (CT) scans for AC, and offer the additional clinical advantages of evaluating coronary calcium, myocardial anatomy (including non-invasive CT angiography), myocardial function, and myocardial perfusion in a single imaging procedure.
Collapse
Affiliation(s)
- Ernest V Garcia
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA.
| |
Collapse
|
50
|
Seller P, Bell S, Cernik R, Christodoulou C, Egan C, Gaskin J, Jacques S, Pani S, Ramsey B, Reid C, Sellin P, Scuffham J, Speller R, Wilson M, Veale M. Pixellated Cd(Zn)Te high-energy X-ray instrument. JOURNAL OF INSTRUMENTATION : AN IOP AND SISSA JOURNAL 2011; 6:C12009. [PMID: 22737179 PMCID: PMC3378031 DOI: 10.1088/1748-0221/6/12/c12009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
We have developed a pixellated high energy X-ray detector instrument to be used in a variety of imaging applications. The instrument consists of either a Cadmium Zinc Telluride or Cadmium Telluride (Cd(Zn)Te) detector bump-bonded to a large area ASIC and packaged with a high performance data acquisition system. The 80 by 80 pixels each of 250 μm by 250 μm give better than 1 keV FWHM energy resolution at 59.5 keV and 1.5 keV FWHM at 141 keV, at the same time providing a high speed imaging performance. This system uses a relatively simple wire-bonded interconnection scheme but this is being upgraded to allow multiple modules to be used with very small dead space. The readout system and the novel interconnect technology is described and how the system is performing in several target applications.
Collapse
Affiliation(s)
- P. Seller
- Technology Department, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, OX110QX, U.K
| | - S. Bell
- Technology Department, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, OX110QX, U.K
| | - R.J. Cernik
- School of Materials, Manchester University, Grosvenor St., Manchester, M1 7HS, U.K
| | - C. Christodoulou
- Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, London, WC1E6BT, U.K
| | - C.K. Egan
- School of Materials, Manchester University, Grosvenor St., Manchester, M1 7HS, U.K
| | - J.A. Gaskin
- NASA Space Science Technology Centre 320 Sparkman Drive, Huntsville, AL 35805, U.S.A
| | - S. Jacques
- School of Materials, Manchester University, Grosvenor St., Manchester, M1 7HS, U.K
| | - S. Pani
- Department of Physics, University of Surrey, Guildford, GU2 7XH, U.K
| | - B.D. Ramsey
- NASA Space Science Technology Centre 320 Sparkman Drive, Huntsville, AL 35805, U.S.A
| | - C. Reid
- Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, London, WC1E6BT, U.K
| | - P.J. Sellin
- Department of Physics, University of Surrey, Guildford, GU2 7XH, U.K
| | - J.W. Scuffham
- Department of Physics, University of Surrey, Guildford, GU2 7XH, U.K
- Nuclear Medicine Department, Royal Surrey County Hospital, Egerton Road, Guildford, GU2 7XX, U.K
| | - R.D. Speller
- Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, London, WC1E6BT, U.K
| | - M.D. Wilson
- Technology Department, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, OX110QX, U.K
| | - M.C. Veale
- Technology Department, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, OX110QX, U.K
| |
Collapse
|