1
|
Yousefzadeh F, Yazdi M, Entezarmahdi SM, Faghihi R, Ghasempoor S, Shahamiri N, Mehrizi ZA, Haghighatafshar M. SPECT-MPI iterative denoising during the reconstruction process using a two-phase learned convolutional neural network. EJNMMI Phys 2024; 11:82. [PMID: 39378001 PMCID: PMC11461437 DOI: 10.1186/s40658-024-00687-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Accepted: 09/26/2024] [Indexed: 10/11/2024] Open
Abstract
PURPOSE The problem of image denoising in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a fundamental challenge. Although various image processing techniques have been presented, they may degrade the contrast of denoised images. The proposed idea in this study is to use a deep neural network as the denoising procedure during the iterative reconstruction process rather than the post-reconstruction phase. This method could decrease the background coefficient of variation (COV_bkg) of the final reconstructed image, which represents the amount of random noise, while improving the contrast-to-noise ratio (CNR). METHODS In this study, a generative adversarial network is used, where its generator is trained by a two-phase approach. In the first phase, the network is trained by a confined image region around the heart in transverse view. The second phase improves the network's generalization by tuning the network weights with the full image size as the input. The network was trained and tested by a dataset of 247 patients who underwent two immediate serially high- and low-noise SPECT-MPI. RESULTS Quantitative results show that compared to post-reconstruction low pass filtering and post-reconstruction deep denoising methods, our proposed method can decline the COV_bkg of the images by up to 10.28% and 12.52% and enhance the CNR by up to 54.54% and 45.82%, respectively. CONCLUSION The iterative deep denoising method outperforms 2D low-pass Gaussian filtering with an 8.4-mm FWHM and post-reconstruction deep denoising approaches.
Collapse
Affiliation(s)
- Farnaz Yousefzadeh
- Department of Computer Science and Engineering and IT, School of Electrical and Computer Engineering, Shiraz University, Shiraz, Iran
| | - Mehran Yazdi
- School of Electrical and Computer Engineering, Shiraz University, Shiraz, Iran.
| | | | - Reza Faghihi
- Department of Nuclear Engineering, Shiraz University, Shiraz, Iran
| | - Sadegh Ghasempoor
- Department of Nuclear Medicine, Alzahra Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
| | | | - Zahra Abuee Mehrizi
- Department of Nuclear Medicine, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mahdi Haghighatafshar
- Department of Nuclear Medicine, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
2
|
Du Y, Sun J, Li CY, Yang BH, Wu TH, Mok GSP. Deep learning-based multi-frequency denoising for myocardial perfusion SPECT. EJNMMI Phys 2024; 11:80. [PMID: 39356406 PMCID: PMC11447183 DOI: 10.1186/s40658-024-00680-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 09/04/2024] [Indexed: 10/03/2024] Open
Abstract
BACKGROUND Deep learning (DL)-based denoising has been proven to improve image quality and quantitation accuracy of low dose (LD) SPECT. However, conventional DL-based methods used SPECT images with mixed frequency components. This work aims to develop an integrated multi-frequency denoising network to further enhance LD myocardial perfusion (MP) SPECT denoising. METHODS Fifty anonymized patients who underwent routine 99mTc-sestamibi stress SPECT/CT scans were retrospectively recruited. Three LD datasets were obtained by reducing the 10 s acquisition time of full dose (FD) SPECT to be 5, 2 and 1 s per projection based on the list mode data for a total of 60 projections. FD and LD projections were Fourier transformed to magnitude and phase images, which were then separated into two or three frequency bands. Each frequency band was then inversed Fourier transformed back to the image domain. We proposed a 3D integrated attention-guided multi-frequency conditional generative adversarial network (AttMFGAN) and compared with AttGAN, and separate AttGAN for multi-frequency bands denoising (AttGAN-MF).The multi-frequency FD and LD projections of 35, 5 and 10 patients were paired for training, validation and testing. The LD projections to be tested were separated to multi-frequency components and input to corresponding networks to get the denoised components, which were summed to get the final denoised projections. Voxel-based error indices were measured on the cardiac region on the reconstructed images. The perfusion defect size (PDS) was also analyzed. RESULTS AttGAN-MF and AttMFGAN have superior performance on all physical and clinical indices as compared to conventional AttGAN. The integrated AttMFGAN is better than AttGAN-MF. Multi-frequency denoising with two frequency bands have generally better results than corresponding three-frequency bands methods. CONCLUSIONS AttGAN-MF and AttMFGAN are promising to further improve LD MP SPECT denoising.
Collapse
Affiliation(s)
- Yu Du
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China
| | - Jingzhang Sun
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- School of Cyberspace Security, Hainan University, Haikou, Hainan, China
| | - Chien-Ying Li
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Bang-Hung Yang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Tung-Hsin Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China.
| |
Collapse
|
3
|
Chen X, Zhou B, Guo X, Xie H, Liu Q, Duncan JS, Sinusas AJ, Liu C. DuDoCFNet: Dual-Domain Coarse-to-Fine Progressive Network for Simultaneous Denoising, Limited-View Reconstruction, and Attenuation Correction of Cardiac SPECT. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:3110-3125. [PMID: 38578853 DOI: 10.1109/tmi.2024.3385650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/07/2024]
Abstract
Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of coronary artery diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-view (LV) SPECT, such as the latest GE MyoSPECT ES system, enables accelerated scanning and reduces hardware expenses but degrades reconstruction accuracy. Additionally, Computed Tomography (CT) is commonly used to derive attenuation maps ( μ -maps) for attenuation correction (AC) of cardiac SPECT, but it will introduce additional radiation exposure and SPECT-CT misalignments. Although various methods have been developed to solely focus on LD denoising, LV reconstruction, or CT-free AC in SPECT, the solution for simultaneously addressing these tasks remains challenging and under-explored. Furthermore, it is essential to explore the potential of fusing cross-domain and cross-modality information across these interrelated tasks to further enhance the accuracy of each task. Thus, we propose a Dual-Domain Coarse-to-Fine Progressive Network (DuDoCFNet), a multi-task learning method for simultaneous LD denoising, LV reconstruction, and CT-free μ -map generation of cardiac SPECT. Paired dual-domain networks in DuDoCFNet are cascaded using a multi-layer fusion mechanism for cross-domain and cross-modality feature fusion. Two-stage progressive learning strategies are applied in both projection and image domains to achieve coarse-to-fine estimations of SPECT projections and CT-derived μ -maps. Our experiments demonstrate DuDoCFNet's superior accuracy in estimating projections, generating μ -maps, and AC reconstructions compared to existing single- or multi-task learning methods, under various iterations and LD levels. The source code of this work is available at https://github.com/XiongchaoChen/DuDoCFNet-MultiTask.
Collapse
|
4
|
Miller RJH, Slomka PJ. Artificial Intelligence in Nuclear Cardiology: An Update and Future Trends. Semin Nucl Med 2024; 54:648-657. [PMID: 38521708 DOI: 10.1053/j.semnuclmed.2024.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 02/19/2024] [Indexed: 03/25/2024]
Abstract
Myocardial perfusion imaging (MPI), using either single photon emission computed tomography (SPECT) or positron emission tomography (PET), is one of the most commonly ordered cardiac imaging tests, with prominent clinical roles for disease diagnosis and risk prediction. Artificial intelligence (AI) could potentially play a role in many steps along the typical MPI workflow, from image acquisition through to clinical reporting and risk estimation. AI can be utilized to improve image quality, reducing radiation exposure and image acquisition times. Once images are acquired, AI can help optimize motion correction and image registration during image reconstruction or provide direct image attenuation correction. Utilizing these image sets, AI can segment a number of anatomic features from associated computed tomographic imaging or even generate synthetic attenuation imaging. Lastly, AI may play an important role in disease diagnosis or risk prediction by combining the large number of potentially important clinical, stress, and imaging-related variables. This review will focus on the most recent developments in the field, providing clinicians and researchers with a timely update on the field. Additionally, it will discuss future trends including applications of AI during multiple points of the typical MPI workflow to maximize clinical utility and methods to maximize the information that can be obtained from hybrid imaging.
Collapse
Affiliation(s)
- Robert J H Miller
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Biomedical Sciences, and Imaging, Cedars-Sinai Medical Center, Los Angeles, CA; Department of Cardiac Sciences, University of Calgary, Calgary, AB, Canada
| | - Piotr J Slomka
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Biomedical Sciences, and Imaging, Cedars-Sinai Medical Center, Los Angeles, CA.
| |
Collapse
|
5
|
Miller RJH, Slomka PJ. Current status and future directions in artificial intelligence for nuclear cardiology. Expert Rev Cardiovasc Ther 2024; 22:367-378. [PMID: 39001698 DOI: 10.1080/14779072.2024.2380764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 07/12/2024] [Indexed: 07/18/2024]
Abstract
INTRODUCTION Myocardial perfusion imaging (MPI) is one of the most commonly ordered cardiac imaging tests. Accurate motion correction, image registration, and reconstruction are critical for high-quality imaging, but this can be technically challenging and has traditionally relied on expert manual processing. With accurate processing, there is a rich variety of clinical, stress, functional, and anatomic data that can be integrated to guide patient management. AREAS COVERED PubMed and Google Scholar were reviewed for articles related to artificial intelligence in nuclear cardiology published between 2020 and 2024. We will outline the prominent roles for artificial intelligence (AI) solutions to provide motion correction, image registration, and reconstruction. We will review the role for AI in extracting anatomic data for hybrid MPI which is otherwise neglected. Lastly, we will discuss AI methods to integrate the wealth of data to improve disease diagnosis or risk stratification. EXPERT OPINION There is growing evidence that AI will transform the performance of MPI by automating and improving on aspects of image acquisition and reconstruction. Physicians and researchers will need to understand the potential strengths of AI in order to benefit from the full clinical utility of MPI.
Collapse
Affiliation(s)
- Robert J H Miller
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Biomedical Sciences, and Imaging, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- Department of Cardiac Sciences, University of Calgary, Calgary, Canada
| | - Piotr J Slomka
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Biomedical Sciences, and Imaging, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| |
Collapse
|
6
|
Rahman MA, Yu Z, Laforest R, Abbey CK, Siegel BA, Jha AK. DEMIST: A Deep-Learning-Based Detection-Task-Specific Denoising Approach for Myocardial Perfusion SPECT. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2024; 8:439-450. [PMID: 38766558 PMCID: PMC11101197 DOI: 10.1109/trpms.2024.3379215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
Abstract
There is an important need for methods to process myocardial perfusion imaging (MPI) single-photon emission computed tomography (SPECT) images acquired at lower-radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects compared to low-dose images. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners (N = 338). The evaluation was performed at low-dose levels of 6.25%, 12.5%, and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic deep learning-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.
Collapse
Affiliation(s)
- Md Ashequr Rahman
- Department of Biomedical Engineering, Washington University, St. Louis, MO 63130 USA
| | - Zitong Yu
- Department of Biomedical Engineering, Washington University, St. Louis, MO 63130 USA
| | - Richard Laforest
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63130 USA
| | - Craig K Abbey
- Department of Psychological and Brain Sciences, University of California at Santa Barbara, Santa Barbara, CA 93106 USA
| | - Barry A Siegel
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63130 USA
| | - Abhinav K Jha
- Department of Biomedical Engineering and the Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63130 USA
| |
Collapse
|
7
|
Xie H, Liu Q, Zhou B, Chen X, Guo X, Wang H, Li B, Rominger A, Shi K, Liu C. Unified Noise-aware Network for Low-count PET Denoising with Varying Count Levels. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2024; 8:366-378. [PMID: 39391291 PMCID: PMC11463975 DOI: 10.1109/trpms.2023.3334105] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/12/2024]
Abstract
As PET imaging is accompanied by substantial radiation exposure and cancer risk, reducing radiation dose in PET scans is an important topic. However, low-count PET scans often suffer from high image noise, which can negatively impact image quality and diagnostic performance. Recent advances in deep learning have shown great potential for recovering underlying signal from noisy counterparts. However, neural networks trained on a specific noise level cannot be easily generalized to other noise levels due to different noise amplitude and variances. To obtain optimal denoised results, we may need to train multiple networks using data with different noise levels. But this approach may be infeasible in reality due to limited data availability. Denoising dynamic PET images presents additional challenge due to tracer decay and continuously changing noise levels across dynamic frames. To address these issues, we propose a Unified Noise-aware Network (UNN) that combines multiple sub-networks with varying denoising power to generate optimal denoised results regardless of the input noise levels. Evaluated using large-scale data from two medical centers with different vendors, presented results showed that the UNN can consistently produce promising denoised results regardless of input noise levels, and demonstrate superior performance over networks trained on single noise level data, especially for extremely low-count data.
Collapse
Affiliation(s)
- Huidong Xie
- Department of Biomedical Engineering, Yale University
| | - Qiong Liu
- Department of Biomedical Engineering, Yale University
| | - Bo Zhou
- Department of Biomedical Engineering, Yale University
| | | | - Xueqi Guo
- Department of Biomedical Engineering, Yale University
| | - Hanzhong Wang
- Department of Nuclear Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
| | - Biao Li
- Department of Nuclear Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
| | - Axel Rominger
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern
| | - Kuangyu Shi
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern
- Computer Aided Medical Procedures and Augmented Reality, Institute of Informatics 116, Technical University of Munich, Munich, Germany
| | - Chi Liu
- Department of Biomedical Engineering, Yale University
- Department of Radiology and Biomedical Imaging at Yale University
| |
Collapse
|
8
|
Azimi MS, Kamali-Asl A, Ay MR, Zeraatkar N, Hosseini MS, Sanaat A, Dadgar H, Arabi H. Deep learning-based partial volume correction in standard and low-dose positron emission tomography-computed tomography imaging. Quant Imaging Med Surg 2024; 14:2146-2164. [PMID: 38545051 PMCID: PMC10963814 DOI: 10.21037/qims-23-871] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 11/20/2023] [Indexed: 08/05/2024]
Abstract
BACKGROUND Positron emission tomography (PET) imaging encounters the obstacle of partial volume effects, arising from its limited intrinsic resolution, giving rise to (I) considerable bias, particularly for structures comparable in size to the point spread function (PSF) of the system; and (II) blurred image edges and blending of textures along the borders. We set out to build a deep learning-based framework for predicting partial volume corrected full-dose (FD + PVC) images from either standard or low-dose (LD) PET images without requiring any anatomical data in order to provide a joint solution for partial volume correction and de-noise LD PET images. METHODS We trained a modified encoder-decoder U-Net network with standard of care or LD PET images as the input and FD + PVC images by six different PVC methods as the target. These six PVC approaches include geometric transfer matrix (GTM), multi-target correction (MTC), region-based voxel-wise correction (RBV), iterative Yang (IY), reblurred Van-Cittert (RVC), and Richardson-Lucy (RL). The proposed models were evaluated using standard criteria, such as peak signal-to-noise ratio (PSNR), root mean squared error (RMSE), structural similarity index (SSIM), relative bias, and absolute relative bias. RESULTS Different levels of error were observed for these partial volume correction methods, which were relatively smaller for GTM with a SSIM of 0.63 for LD and 0.29 for FD, IY with an SSIM of 0.63 for LD and 0.67 for FD, RBV with an SSIM of 0.57 for LD and 0.65 for FD, and RVC with an SSIM of 0.89 for LD and 0.94 for FD PVC approaches. However, large quantitative errors were observed for multi-target MTC with an RMSE of 2.71 for LD and 2.45 for FD and RL with an RMSE of 5 for LD and 3.27 for FD PVC approaches. CONCLUSIONS We found that the proposed framework could effectively perform joint de-noising and partial volume correction for PET images with LD and FD input PET data (LD vs. FD). When no magnetic resonance imaging (MRI) images are available, the developed deep learning models could be used for partial volume correction on LD or standard PET-computed tomography (PET-CT) scans as an image quality enhancement technique.
Collapse
Affiliation(s)
- Mohammad-Saber Azimi
- Department of Medical Radiation Engineering, Shahid Beheshti University, Tehran, Iran
- Research Center for Molecular and Cellular Imaging (RCMCI), Advanced Medical Technologies and Equipment Institute (AMTEI), Tehran University of Medical Sciences (TUMS), Tehran, Iran
| | - Alireza Kamali-Asl
- Department of Medical Radiation Engineering, Shahid Beheshti University, Tehran, Iran
| | - Mohammad-Reza Ay
- Research Center for Molecular and Cellular Imaging (RCMCI), Advanced Medical Technologies and Equipment Institute (AMTEI), Tehran University of Medical Sciences (TUMS), Tehran, Iran
- Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | - Amirhossein Sanaat
- Division of Nuclear Medicine & Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
| | - Habibollah Dadgar
- Cancer Research Center, Razavi Hospital, Imam Reza International University, Mashhad, Iran
| | - Hossein Arabi
- Division of Nuclear Medicine & Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
| |
Collapse
|
9
|
Bousse A, Kandarpa VSS, Shi K, Gong K, Lee JS, Liu C, Visvikis D. A Review on Low-Dose Emission Tomography Post-Reconstruction Denoising with Neural Network Approaches. ARXIV 2024:arXiv:2401.00232v2. [PMID: 38313194 PMCID: PMC10836084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 02/06/2024]
Abstract
Low-dose emission tomography (ET) plays a crucial role in medical imaging, enabling the acquisition of functional information for various biological processes while minimizing the patient dose. However, the inherent randomness in the photon counting process is a source of noise which is amplified in low-dose ET. This review article provides an overview of existing post-processing techniques, with an emphasis on deep neural network (NN) approaches. Furthermore, we explore future directions in the field of NN-based low-dose ET. This comprehensive examination sheds light on the potential of deep learning in enhancing the quality and resolution of low-dose ET images, ultimately advancing the field of medical imaging.
Collapse
Affiliation(s)
| | | | - Kuangyu Shi
- Lab for Artificial Intelligence & Translational Theranostics, Dept. Nuclear Medicine, Inselspital, University of Bern, 3010 Bern, Switzerland
| | - Kuang Gong
- The Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital/Harvard Medical School, Boston, MA 02114, USA
| | - Jae Sung Lee
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 03080, Korea
| | - Chi Liu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | | |
Collapse
|
10
|
Li J, Yang G, Zhang L. Artificial Intelligence Empowered Nuclear Medicine and Molecular Imaging in Cardiology: A State-of-the-Art Review. PHENOMICS (CHAM, SWITZERLAND) 2023; 3:586-596. [PMID: 38223683 PMCID: PMC10781930 DOI: 10.1007/s43657-023-00137-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 10/13/2023] [Accepted: 10/16/2023] [Indexed: 01/16/2024]
Abstract
Nuclear medicine and molecular imaging plays a significant role in the detection and management of cardiovascular disease (CVD). With recent advancements in computer power and the availability of digital archives, artificial intelligence (AI) is rapidly gaining traction in the field of medical imaging, including nuclear medicine and molecular imaging. However, the complex and time-consuming workflow and interpretation involved in nuclear medicine and molecular imaging, limit their extensive utilization in clinical practice. To address this challenge, AI has emerged as a fundamental tool for enhancing the role of nuclear medicine and molecular imaging. It has shown promising applications in various crucial aspects of nuclear cardiology, such as optimizing imaging protocols, facilitating data processing, aiding in CVD diagnosis, risk classification and prognosis. In this review paper, we will introduce the key concepts of AI and provide an overview of its current progress in the field of nuclear cardiology. In addition, we will discuss future perspectives for AI in this domain.
Collapse
Affiliation(s)
- Junhao Li
- Department of Nuclear Medicine, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 305 Zhongshan East Road, Xuanwu District, Nanjing, 210002 Jiangsu China
| | - Guifen Yang
- Department of Nuclear Medicine, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 305 Zhongshan East Road, Xuanwu District, Nanjing, 210002 Jiangsu China
| | - Longjiang Zhang
- Department of Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 305 Zhongshan East Road, Xuanwu District, Nanjing, 210002 Jiangsu China
| |
Collapse
|
11
|
Yang C, Ko K, Lin P. Reducing scan time in 177 Lu planar scintigraphy using convolutional neural network: A Monte Carlo simulation study. J Appl Clin Med Phys 2023; 24:e14056. [PMID: 37261890 PMCID: PMC10562044 DOI: 10.1002/acm2.14056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 05/15/2022] [Accepted: 05/16/2023] [Indexed: 06/02/2023] Open
Abstract
PURPOSE The aim of this study was to reduce scan time in 177 Lu planar scintigraphy through the use of convolutional neural network (CNN) to facilitate personalized dosimetry for 177 Lu-based peptide receptor radionuclide therapy. METHODS The CNN model used in this work was based on DenseNet, and the training and testing datasets were generated from Monte Carlo simulation. The CNN input images (IMGinput ) consisted of 177 Lu planar scintigraphy that contained 10-90% of the total photon counts, while the corresponding full-count images (IMG100% ) were used as the CNN label images. Two-sample t-test was conducted to compare the difference in pixel intensities within region of interest between IMG100% and CNN output images (IMGoutput ). RESULTS No difference was found in IMGoutput for rods with diameters ranging from 13 to 33 mm in the Derenzo phantom with a target-to-background ratio of 20:1, while statistically significant differences were found in IMGoutput for the 10-mm diameter rods when IMGinput containing 10% to 60% of the total photon counts were denoised. Statistically significant differences were found in IMGoutput for both right and left kidneys in the NCAT phantom when IMGinput containing 10% of the total photon counts were denoised. No statistically significant differences were found in IMGoutput for any other source organs in the NCAT phantom. CONCLUSION Our results showed that the proposed method can reduce scan time by up to 70% for objects larger than 13 mm, making it a useful tool for personalized dosimetry in 177 Lu-based peptide receptor radionuclide therapy in clinical practice.
Collapse
Affiliation(s)
- Ching‐Ching Yang
- Department of Medical Imaging and Radiological SciencesKaohsiung Medical UniversityKaohsiungTaiwan
- Department of Medical ResearchKaohsiung Medical University Chung‐Ho Memorial HospitalKaohsiungTaiwan
| | - Kuan‐Yin Ko
- Department of Nuclear MedicineNational Taiwan University Cancer CenterTaipeiTaiwan
- Graduate Institute of Clinical MedicineCollege of MedicineNational Taiwan UniversityTaipeiTaiwan
| | - Pei‐Yao Lin
- Department of Nuclear MedicineNational Taiwan University Cancer CenterTaipeiTaiwan
| |
Collapse
|
12
|
Sohlberg A, Kangasmaa T, Tikkakoski A. Comparison of post reconstruction- and reconstruction-based deep learning denoising methods in cardiac SPECT. Biomed Phys Eng Express 2023; 9:065007. [PMID: 37666231 DOI: 10.1088/2057-1976/acf66c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 09/04/2023] [Indexed: 09/06/2023]
Abstract
Objective. The quality of myocardial perfusion SPECT (MPS) images is often hampered by low count statistics. Poor image quality might hinder reporting the studies and in the worst case lead to erroneous diagnosis. Deep learning (DL)-based methods can be used to improve the quality of the low count studies. DL can be applied in several different methods, which might affect the outcome. The aim of this study was to investigate the differences between post reconstruction- and reconstruction-based denoising methods.Approach. A UNET-type network was trained using ordered subsets expectation maximization (OSEM) reconstructed MPS studies acquired with half, quarter and eighth of full-activity. The trained network was applied as a post reconstruction denoiser (OSEM+DL) and it was incorporated into a regularized reconstruction algorithm as a deep learning penalty (DLP). OSEM+DL and DLP were compared against each other and against OSEM images without DL denoising in terms of noise level, myocardium-ventricle contrast and defect detection performance with signal-to-noise ratio of a non-prewhitening matched filter (NPWMF-SNR) applied to artificial perfusion defects inserted into defect-free clinical MPS scans. Comparisons were made using half-, quarter- and eighth-activity data.Main results. OSEM+DL provided lower noise level at all activities than other methods. DLP's noise level was also always lower than matching activity OSEM's. In addition, OSEM+DL and DLP outperformed OSEM in defect detection performance, but contrary to noise level ranking DLP had higher NPWMF-SNR overall than OSEM+DL. The myocardium-ventricle contrast was highest with DLP and lowest with OSEM+DL. Both OSEM+DL and DLP offered better image quality than OSEM, but visually perfusion defects were deeper in OSEM images at low activities.Significance. Both post reconstruction- and reconstruction-based DL denoising methods have great potential for MPS. The preference between these methods is a trade-off between smoother images and better defect detection performance.
Collapse
Affiliation(s)
- Antti Sohlberg
- Department of Nuclear Medicine, Päijät-Häme Central Hospital, Lahti, Finland
- HERMES Medical Solutions, Stockholm, Sweden
| | - Tuija Kangasmaa
- Department of Clinical Physiology and Nuclear Medicine, Vaasa Central Hospital, Vaasa, Finland
| | - Antti Tikkakoski
- Clinical Physiology and Nuclear Medicine, Tampere University Hospital, Tampere, Finland
| |
Collapse
|
13
|
Sanaei B, Faghihi R, Arabi H. Employing Multiple Low-Dose PET Images (at Different Dose Levels) as Prior Knowledge to Predict Standard-Dose PET Images. J Digit Imaging 2023; 36:1588-1596. [PMID: 36988836 PMCID: PMC10406788 DOI: 10.1007/s10278-023-00815-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 03/13/2023] [Accepted: 03/15/2023] [Indexed: 03/30/2023] Open
Abstract
The existing deep learning-based denoising methods predicting standard-dose PET images (S-PET) from the low-dose versions (L-PET) solely rely on a single-dose level of PET images as the input of deep learning network. In this work, we exploited the prior knowledge in the form of multiple low-dose levels of PET images to estimate the S-PET images. To this end, a high-resolution ResNet architecture was utilized to predict S-PET images from 6 to 4% L-PET images. For the 6% L-PET imaging, two models were developed; the first and second models were trained using a single input of 6% L-PET and three inputs of 6%, 4%, and 2% L-PET as input to predict S-PET images, respectively. Similarly, for 4% L-PET imaging, a model was trained using a single input of 4% low-dose data, and a three-channel model was developed getting 4%, 3%, and 2% L-PET images. The performance of the four models was evaluated using structural similarity index (SSI), peak signal-to-noise ratio (PSNR), and root mean square error (RMSE) within the entire head regions and malignant lesions. The 4% multi-input model led to improved SSI and PSNR and a significant decrease in RMSE by 22.22% and 25.42% within the entire head region and malignant lesions, respectively. Furthermore, the 4% multi-input network remarkably decreased the lesions' SUVmean bias and SUVmax bias by 64.58% and 37.12% comparing to single-input network. In addition, the 6% multi-input network decreased the RMSE within the entire head region, within the lesions, lesions' SUVmean bias, and SUVmax bias by 37.5%, 39.58%, 86.99%, and 45.60%, respectively. This study demonstrated the significant benefits of using prior knowledge in the form of multiple L-PET images to predict S-PET images.
Collapse
Affiliation(s)
- Behnoush Sanaei
- Nuclear Engineering Department, Shiraz University, Shiraz, Iran
| | - Reza Faghihi
- Nuclear Engineering Department, Shiraz University, Shiraz, Iran
| | - Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging, Department of Medical Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| |
Collapse
|
14
|
Pashazadeh A, Hoeschen C. [Opportunities for artificial intelligence in radiation protection : Improving safety of diagnostic imaging]. RADIOLOGIE (HEIDELBERG, GERMANY) 2023; 63:530-538. [PMID: 37347256 PMCID: PMC10299955 DOI: 10.1007/s00117-023-01167-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/16/2023] [Indexed: 06/23/2023]
Abstract
CLINICAL/METHODOLOGICAL ISSUE Imaging of structures of internal organs often requires ionizing radiation, which is a health risk. Reducing the radiation dose can increase the image noise, which means that images provide less information. STANDARD RADIOLOGICAL METHODS This problem is observed in commonly used medical imaging modalities such as computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), angiography, fluoroscopy, and any modality that uses ionizing radiation for imaging. METHODOLOGICAL INNOVATIONS Artificial intelligence (AI) can improve the quality of low-dose images and help minimize radiation exposure. Potential applications are explored, and frameworks and procedures are critically evaluated. PERFORMANCE The performance of AI models varies. High-performance models could be used in clinical settings in the near future. Several challenges (e.g., quantitative accuracy, insufficient training data) must be addressed for optimal performance and widespread adoption of this technology in the field of medical imaging. PRACTICAL RECOMMENDATIONS To fully realize the potential of AI and deep learning (DL) in medical imaging, research and development must be intensified. In particular, quality control of AI models must be ensured, and training and testing data must be uncorrelated and quality assured. With sufficient scientific validation and rigorous quality management, AI could contribute to the safe use of low-dose techniques in medical imaging.
Collapse
Affiliation(s)
- Ali Pashazadeh
- Institut für Medizintechnik (IMT), Otto-von-Guericke-Universität Magdeburg, Otto-Hahn-Str. 2, 39016, Magdeburg, Deutschland.
| | - Christoph Hoeschen
- Institut für Medizintechnik (IMT), Otto-von-Guericke-Universität Magdeburg, Otto-Hahn-Str. 2, 39016, Magdeburg, Deutschland
| |
Collapse
|
15
|
Sun J, Jiang H, Du Y, Li CY, Wu TH, Liu YH, Yang BH, Mok GSP. Deep learning-based denoising in projection-domain and reconstruction-domain for low-dose myocardial perfusion SPECT. J Nucl Cardiol 2023; 30:970-985. [PMID: 35982208 DOI: 10.1007/s12350-022-03045-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 06/13/2022] [Indexed: 10/15/2022]
Abstract
BACKGROUND Low-dose (LD) myocardial perfusion (MP) SPECT suffers from high noise level, leading to compromised diagnostic accuracy. Here we investigated the denoising performance for MP-SPECT using a conditional generative adversarial network (cGAN) in projection-domain (cGAN-prj) and reconstruction-domain (cGAN-recon). METHODS Sixty-four noisy SPECT projections were simulated for a population of 100 XCAT phantoms with different anatomical variations and 99mTc-sestamibi distributions. Series of LD projections were obtained by scaling the full dose (FD) count rate to be 1/20 to 1/2 of the original. Twenty patients with 99mTc-sestamibi stress SPECT/CT scans were retrospectively analyzed. For each patient, LD SPECT images (7/10 to 1/10 of FD) were generated from the FD list mode data. All projections were reconstructed by the quantitative OS-EM method. A 3D cGAN was implemented to predict FD images from their corresponding LD images in the projection- and reconstruction-domain. The denoised projections were reconstructed for analysis in various quantitative indices along with cGAN-recon, Gaussian, and Butterworth-filtered images. RESULTS cGAN denoising improves image quality as compared to LD and conventional post-reconstruction filtering. cGAN-prj can further reduce the dose level as compared to cGAN-recon without compromising the image quality. CONCLUSIONS Denoising based on cGAN-prj is superior to cGAN-recon for MP-SPECT.
Collapse
Affiliation(s)
- Jingzhang Sun
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China
| | - Han Jiang
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China
| | - Yu Du
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China
| | - Chien-Ying Li
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Tung-Hsin Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
| | - Yi-Hwa Liu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Internal Medicine, Yale University School of Medicine, New Haven, CT, USA
| | - Bang-Hung Yang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.
- Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China.
| |
Collapse
|
16
|
Xie H, Liu Z, Shi L, Greco K, Chen X, Zhou B, Feher A, Stendahl JC, Boutagy N, Kyriakides TC, Wang G, Sinusas AJ, Liu C. Segmentation-Free PVC for Cardiac SPECT Using a Densely-Connected Multi-Dimensional Dynamic Network. IEEE TRANSACTIONS ON MEDICAL IMAGING 2023; 42:1325-1336. [PMID: 36459599 PMCID: PMC10204821 DOI: 10.1109/tmi.2022.3226604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
In nuclear imaging, limited resolution causes partial volume effects (PVEs) that affect image sharpness and quantitative accuracy. Partial volume correction (PVC) methods incorporating high-resolution anatomical information from CT or MRI have been demonstrated to be effective. However, such anatomical-guided methods typically require tedious image registration and segmentation steps. Accurately segmented organ templates are also hard to obtain, particularly in cardiac SPECT imaging, due to the lack of hybrid SPECT/CT scanners with high-end CT and associated motion artifacts. Slight mis-registration/mis-segmentation would result in severe degradation in image quality after PVC. In this work, we develop a deep-learning-based method for fast cardiac SPECT PVC without anatomical information and associated organ segmentation. The proposed network involves a densely-connected multi-dimensional dynamic mechanism, allowing the convolutional kernels to be adapted based on the input images, even after the network is fully trained. Intramyocardial blood volume (IMBV) is introduced as an additional clinical-relevant loss function for network optimization. The proposed network demonstrated promising performance on 28 canine studies acquired on a GE Discovery NM/CT 570c dedicated cardiac SPECT scanner with a 64-slice CT using Technetium-99m-labeled red blood cells. This work showed that the proposed network with densely-connected dynamic mechanism produced superior results compared with the same network without such mechanism. Results also showed that the proposed network without anatomical information could produce images with statistically comparable IMBV measurements to the images generated by anatomical-guided PVC methods, which could be helpful in clinical translation.
Collapse
|
17
|
Sohlberg A, Kangasmaa T, Constable C, Tikkakoski A. Comparison of deep learning-based denoising methods in cardiac SPECT. EJNMMI Phys 2023; 10:9. [PMID: 36752847 PMCID: PMC9908801 DOI: 10.1186/s40658-023-00531-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 02/01/2023] [Indexed: 02/09/2023] Open
Abstract
BACKGROUND Myocardial perfusion SPECT (MPS) images often suffer from artefacts caused by low-count statistics. Poor-quality images can lead to misinterpretations of perfusion defects. Deep learning (DL)-based methods have been proposed to overcome the noise artefacts. The aim of this study was to investigate the differences among several DL denoising models. METHODS Convolution neural network (CNN), residual neural network (RES), UNET and conditional generative adversarial neural network (cGAN) were generated and trained using ordered subsets expectation maximization (OSEM) reconstructed MPS studies acquired with full, half, three-eighths and quarter acquisition time. All DL methods were compared against each other and also against images without DL-based denoising. Comparisons were made using half and quarter time acquisition data. The methods were evaluated in terms of noise level (coefficient of variation of counts, CoV), structural similarity index measure (SSIM) in the myocardium of normal patients and receiver operating characteristic (ROC) analysis of realistic artificial perfusion defects inserted into normal MPS scans. Total perfusion deficit scores were used as observer rating for the presence of a perfusion defect. RESULTS All the DL denoising methods tested provided statistically significantly lower noise level than OSEM without DL-based denoising with the same acquisition time. CoV of the myocardium counts with the different DL noising methods was on average 7% (CNN), 8% (RES), 7% (UNET) and 14% (cGAN) lower than with OSEM. All DL methods also outperformed full time OSEM without DL-based denoising in terms of noise level with both half and quarter acquisition time, but this difference was not statistically significant. cGAN had the lowest CoV of the DL methods at all noise levels. Image quality and polar map uniformity of DL-denoised images were also better than reduced acquisition time OSEM's. SSIM of the reduced acquisition time OSEM was overall higher than with the DL methods. The defect detection performance of full time OSEM measured as area under the ROC curve (AUC) was on average 0.97. Half time OSEM, CNN, RES and UNET provided equal or nearly equal AUC. However, with quarter time data CNN, RES and UNET had an average AUC of 0.93, which was lower than full time OSEM's AUC, but equal to quarter acquisition time OSEM. cGAN did not achieve the defect detection performance of the other DL methods. Its average AUC with half time data was 0.94 and 0.91 with quarter time data. CONCLUSIONS DL-based denoising effectively improved noise level with slightly lower perfusion defect detection performance than full time reconstruction. cGAN achieved the lowest noise level, but at the same time the poorest defect detection performance among the studied DL methods.
Collapse
Affiliation(s)
- Antti Sohlberg
- Department of Clinical Physiology and Nuclear Medicine, Päijät-Häme Central Hospital, Lahti, Finland.
- HERMES Medical Solutions, Stockholm, Sweden.
| | - Tuija Kangasmaa
- Department of Clinical Physiology and Nuclear Medicine, Vaasa Central Hospital, Vaasa, Finland
| | | | - Antti Tikkakoski
- Clinical Physiology and Nuclear Medicine, Tampere University Hospital, Tampere, Finland
| |
Collapse
|
18
|
Sun J, Yang BH, Li CY, Du Y, Liu YH, Wu TH, Mok GSP. Fast myocardial perfusion SPECT denoising using an attention-guided generative adversarial network. Front Med (Lausanne) 2023; 10:1083413. [PMID: 36817784 PMCID: PMC9935600 DOI: 10.3389/fmed.2023.1083413] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Accepted: 01/16/2023] [Indexed: 02/05/2023] Open
Abstract
Purpose Deep learning-based denoising is promising for myocardial perfusion (MP) SPECT. However, conventional convolutional neural network (CNN)-based methods use fixed-sized convolutional kernels to convolute one region within the receptive field at a time, which would be ineffective for learning the feature dependencies across large regions. The attention mechanism (Att) is able to learn the relationships between the local receptive field and other voxels in the image. In this study, we propose a 3D attention-guided generative adversarial network (AttGAN) for denoising fast MP-SPECT images. Methods Fifty patients who underwent 1184 MBq 99mTc-sestamibi stress SPECT/CT scan were retrospectively recruited. Sixty projections were acquired over 180° and the acquisition time was 10 s/view for the full time (FT) mode. Fast MP-SPECT projection images (1 s to 7 s) were generated from the FT list mode data. We further incorporated binary patient defect information (0 = without defect, 1 = with defect) into AttGAN (AttGAN-def). AttGAN, AttGAN-def, cGAN, and Unet were implemented using Tensorflow with the Adam optimizer running up to 400 epochs. FT and fast MP-SPECT projection pairs of 35 patients were used for training the networks for each acquisition time, while 5 and 10 patients were applied for validation and testing. Five-fold cross-validation was performed and data for all 50 patients were tested. Voxel-based error indices, joint histogram, linear regression, and perfusion defect size (PDS) were analyzed. Results All quantitative indices of AttGAN-based networks are superior to cGAN and Unet on all acquisition time images. AttGAN-def further improves AttGAN performance. The mean absolute error of PDS by AttcGAN-def was 1.60 on acquisition time of 1 s/prj, as compared to 2.36, 2.76, and 3.02 by AttGAN, cGAN, and Unet. Conclusion Denoising based on AttGAN is superior to conventional CNN-based networks for MP-SPECT.
Collapse
Affiliation(s)
- Jingzhang Sun
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macao SAR, China
| | - Bang-Hung Yang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Hsinchu, Taiwan,Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - Chien-Ying Li
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Hsinchu, Taiwan,Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - Yu Du
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macao SAR, China
| | - Yi-Hwa Liu
- Department of Internal Medicine, Yale University School of Medicine, New Haven, CT, United States
| | - Tung-Hsin Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Hsinchu, Taiwan,Tung-Hsin Wu,
| | - Greta S. P. Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macao SAR, China,Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macao SAR, China,Ministry of Education Frontiers Science Center for Precision Oncology, Faculty of Health Science, University of Macau, Taipa, Macao SAR, China,*Correspondence: Greta S. P. Mok,
| |
Collapse
|
19
|
Experimental study of noise level optimization in brain single-photon emission computed tomography images using non-local means approach with various reconstruction methods. NUCLEAR ENGINEERING AND TECHNOLOGY 2023. [DOI: 10.1016/j.net.2023.01.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
20
|
Apostolopoulos ID, Papandrianos NI, Feleki A, Moustakidis S, Papageorgiou EI. Deep learning-enhanced nuclear medicine SPECT imaging applied to cardiac studies. EJNMMI Phys 2023; 10:6. [PMID: 36705775 PMCID: PMC9883373 DOI: 10.1186/s40658-022-00522-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Accepted: 12/19/2022] [Indexed: 01/28/2023] Open
Abstract
Deep learning (DL) has a growing popularity and is a well-established method of artificial intelligence for data processing, especially for images and videos. Its applications in nuclear medicine are broad and include, among others, disease classification, image reconstruction, and image de-noising. Positron emission tomography (PET) and single-photon emission computerized tomography (SPECT) are major image acquisition technologies in nuclear medicine. Though several studies have been conducted to apply DL in many nuclear medicine domains, such as cancer detection and classification, few studies have employed such methods for cardiovascular disease applications. The present paper reviews recent DL approaches focused on cardiac SPECT imaging. Extensive research identified fifty-five related studies, which are discussed. The review distinguishes between major application domains, including cardiovascular disease diagnosis, SPECT attenuation correction, image denoising, full-count image estimation, and image reconstruction. In addition, major findings and dominant techniques employed for the mentioned task are revealed. Current limitations of DL approaches and future research directions are discussed.
Collapse
Affiliation(s)
- Ioannis D. Apostolopoulos
- grid.11047.330000 0004 0576 5395Department of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece ,grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| | - Nikolaos I. Papandrianos
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| | - Anna Feleki
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| | - Serafeim Moustakidis
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece ,AIDEAS OÜ, 10117 Tallinn, Estonia
| | - Elpiniki I. Papageorgiou
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| |
Collapse
|
21
|
Murata T. [[SPECT] 5. Application of Artificial Intelligence in Nuclear Medicine for SPECT]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:1230-1236. [PMID: 36261360 DOI: 10.6009/jjrt.2022-2096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
|