1
|
Rengo M, Tiberia F, Vicini S, Bellini D, Celestre M, Trionfera G, Laghi A, Carbone I. CT colonography: can we achieve an adequate bowel preparation without diet restriction? Eur Radiol 2023; 33:5184-5192. [PMID: 36806568 PMCID: PMC10289920 DOI: 10.1007/s00330-023-09471-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 01/13/2023] [Accepted: 01/22/2023] [Indexed: 02/21/2023]
Abstract
OBJECTIVE To evaluate if an adequate bowel preparation for CT colonography, can be achieved without diet restriction, using a reduced amount of cathartic agent and fecal tagging. To investigate the influence of patients' characteristics on bowel preparation and the impact on patients' compliance. METHODS In total, 1446 outpatients scheduled for elective CT colonography were prospectively enrolled. All patients had the same bowel preparation based on a reduced amount of cathartic agent (120 g of macrogol in 1.5 l of water) the day before the exam and a fecal tagging agent (60 ml of hyperosmolar oral iodinated agent) the day of the exam. No dietary restrictions were imposed before the exam. The bowel preparation was evaluated using a qualitative and quantitative score. Patients were grouped by age, gender, and presence of diverticula in both scores. Patients' compliance has been evaluated with a questionnaire after the end of the exam and with a phone-calling interview the day after the exam. RESULTS According to the qualitative score, adequate bowel preparation was achieved in 1349 patients (93.29%) and no statistical differences were observed among the subgroups of patients. Quantitative scores demonstrated that colon distension was significantly better in younger patients and without diverticula. A good patients' compliance was observed and most patients (96.5%) were willing to repeat it. CONCLUSIONS The lack of diet restriction does not affect the quality of CTC preparation and good patient's compliance could potentially increase the participation rate in CRC screening programs. KEY POINTS • An adequate quality bowel preparation for CT colonography can be achieved without diet restriction, using a reduced amount of cathartic agent (120 g of macrogol in 1.5 l of water) and fecal tagging (60 ml of hyperosmolar oral iodinated agent). • A bowel preparation based on the combination of a reduced amount of cathartic agent and fecal tagging, without diet restriction, allows obtaining good quality in more than 90% of patients. • The bowel preparation scheme proposed reduces the distress and discomfort experienced by the patients improving adherence to CTC.
Collapse
Affiliation(s)
- Marco Rengo
- Department of Medico-Surgical Sciences and Biotechnologies, Academic Diagnostic Imaging Unit, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy.
| | - Filippo Tiberia
- Department of Radiological, Oncological and Pathological Sciences, Academic Diagnostic Imaging Unit, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Simone Vicini
- Department of Radiological, Oncological and Pathological Sciences, Academic Diagnostic Imaging Unit, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Davide Bellini
- Department of Medico-Surgical Sciences and Biotechnologies, Academic Diagnostic Imaging Unit, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Michela Celestre
- Diagnostic Imaging Unit, Valmontone Hospital, Via Dei Lecci, Valmontone, RM, Italy
| | - Gianfranco Trionfera
- Diagnostic Imaging Unit, Valmontone Hospital, Via Dei Lecci, Valmontone, RM, Italy
| | - Andrea Laghi
- Department of Surgical and Medical Sciences and Translational Medicine, Radiology Unit, Sant'Andrea University Hospital, "Sapienza" University of Rome, Via Di Grottarossa 1035, 00189, Rome, Italy
| | - Iacopo Carbone
- Department of Radiological, Oncological and Pathological Sciences, Academic Diagnostic Imaging Unit, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy
| |
Collapse
|
2
|
Chen LS, Chen SJ, Hsu TW, Chang SH, Hou CJ, Lin CW, Chen YR, Hsieh CC, Han SC, Chang KY. Exploring the interior of 3D endoluminal lesions in the air spaces by a novel electronic biopsy technique: A preliminary study of endoluminal colon lesions. PLoS One 2023; 18:e0284142. [PMID: 37167339 PMCID: PMC10174533 DOI: 10.1371/journal.pone.0284142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 03/08/2023] [Indexed: 05/13/2023] Open
Abstract
To explore the interior of a lesion in a 3D endoluminal view, this study investigates the application of an 'electronic biopsy' (EB) technique to computed tomographic colonography (CTC) for further differentiation and 2D image correlation of endoluminal lesions in the air spaces. A retrospective study of sixty-two various endoluminal lesions from thirty patients (13 males, 17 females; age range, 31 to 90 years) was approved by our institutional review board and evaluated. The endoluminal lesions were segmented using gray-level threshold and reconstructed into isosurfaces using a marching cube algorithm. EB allows users to interactively erode and apply grey-level mapping (GM) to the surface of the region of interest (ROI) in 3D CTC. Radiologists conducted the clinical evaluation, and the resulting data were analyzed. EB significantly improves 3D gray-level presentation for evaluating the surface and inside of endoluminal lesions over that of SR, GM or target GM (TGM) (P < 0.01) with preservation of the 3D spatial effect. Moreover, 3D to 2D image correlation were achieved in any layer of the lesion using EB as did GM/TGM on the surface. The specificity and diagnostic accuracy of EB are significantly greater than those of SR (P < 0.01). These performance can be better further with GM/TGM and reach the best with EB (specificity, 89.3-92.9%; accuracy, 95.2-96.8%). EB can be used in CTC to improve the differentiation of endoluminal lesions. EB increases 3D to 2D image correlations of the lesions on or beneath the lesion surface.
Collapse
Affiliation(s)
- Lih-Shyang Chen
- Department of Electric Engineering, National Cheng Kung University, Tainan, Taiwan, ROC
| | - Shao-Jer Chen
- School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC
- Department of Medical Imaging, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC
| | - Ta-Wen Hsu
- School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC
- Department of General Surgery, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC
| | - Shu-Han Chang
- Department of Electric Engineering, National Cheng Kung University, Tainan, Taiwan, ROC
| | - Chun-Ju Hou
- Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan, Taiwan, ROC
| | - Chih-Wen Lin
- School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC
- Department of Medical Imaging, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC
| | - Yu-Ruei Chen
- School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC
- Department of Medical Imaging, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC
| | - Chin-Chiang Hsieh
- Department of Radiology, Tainan Hospital, Ministry of Health and Welfare, Tainan, Taiwan, ROC
| | - Shu-Chen Han
- Department of Radiology, Tainan Municipal Hospital, Tainan, Taiwan, ROC
| | - Ku-Yaw Chang
- Department of Computer Science and Information Engineering, Da-Yeh University, Changhua, Taiwan, ROC
| |
Collapse
|
3
|
Grosu S, Wiemker R, An C, Obmann MM, Wong E, Yee J, Yeh BM. Comparison of the performance of conventional and spectral-based tagged stool cleansing algorithms at CT colonography. Eur Radiol 2022; 32:7936-7945. [PMID: 35486170 DOI: 10.1007/s00330-022-08831-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 03/15/2022] [Accepted: 04/20/2022] [Indexed: 01/03/2023]
Abstract
OBJECTIVES To compare the performance of conventional versus spectral-based electronic stool cleansing for iodine-tagged CT colonography (CTC) using a dual-layer spectral detector scanner. METHODS We retrospectively evaluated iodine contrast stool-tagged CTC scans of 30 consecutive patients (mean age: 69 ± 8 years) undergoing colorectal cancer screening obtained on a dual-layer spectral detector CT scanner. One reader identified locations of electronic cleansing artifacts (n = 229) on conventional and spectral cleansed images. Three additional independent readers evaluated these locations using a conventional cleansing algorithm (Intellispace Portal) and two experimental spectral cleansing algorithms (i.e., fully transparent and translucent tagged stool). For each cleansed image set, readers recorded the severity of over- and under-cleansing artifacts on a 5-point Likert scale (0 = none to 4 = severe) and readability compared to uncleansed images. Wilcoxon's signed-rank tests were used to assess artifact severity, type, and readability (worse, unchanged, or better). RESULTS Compared with conventional cleansing (66% score ≥ 2), the severity of overall cleansing artifacts was lower in transparent (60% score ≥ 2, p = 0.011) and translucent (50% score ≥ 2, p < 0.001) spectral cleansing. Under-cleansing artifact severity was lower in transparent (49% score ≥ 2, p < 0.001) and translucent (39% score ≥ 2, p < 0.001) spectral cleansing compared with conventional cleansing (60% score ≥ 2). Over-cleansing artifact severity was worse in transparent (17% score ≥ 2, p < 0.001) and translucent (14% score ≥ 2, p = 0.023) spectral cleansing compared with conventional cleansing (9% score ≥ 2). Overall readability was significantly improved in transparent (p < 0.001) and translucent (p < 0.001) spectral cleansing compared with conventional cleansing. CONCLUSIONS Spectral cleansing provided more robust electronic stool cleansing of iodine-tagged stool at CTC than conventional cleansing. KEY POINTS • Spectral-based electronic cleansing of tagged stool at CT colonography provides higher quality images with less perception of artifacts than does conventional cleansing. • Spectral-based electronic cleansing could potentially advance minimally cathartic approach for CT colonography. Further clinical trials are warranted.
Collapse
Affiliation(s)
- Sergio Grosu
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Avenue, San Francisco, CA, 94143, USA.
- Department of Radiology, University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany.
| | - Rafael Wiemker
- Philips Research Laboratories Hamburg, Röntgenstraße 24, 22335, Hamburg, Germany
| | - Chansik An
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Avenue, San Francisco, CA, 94143, USA
| | - Markus M Obmann
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Avenue, San Francisco, CA, 94143, USA
- Department of Radiology and Nuclear Imaging, University Hospital Basel, Petersgraben 4, CH - 4051, Basel, Switzerland
| | - Eddy Wong
- CT/AMI Clinical Science, Philips Healthcare, 100 Park Avenue, Orange Village, OH, 44122, USA
| | - Judy Yee
- Department of Radiology, Montefiore Medical Center, Albert Einstein College of Medicine, 111 E 210th Street, Bronx, NY, 10467-2401, USA
| | - Benjamin M Yeh
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Avenue, San Francisco, CA, 94143, USA
| |
Collapse
|
4
|
Bellini D, Panvini N, Vicini S, Rengo M, Lucchesi P, Caruso D, Carbone I, Laghi A. Low-volume reduced bowel preparation regimen for CT colonography: a randomized noninferiority trial. Abdom Radiol (NY) 2021; 46:4556-4566. [PMID: 34143258 DOI: 10.1007/s00261-021-03176-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Revised: 06/08/2021] [Accepted: 06/10/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE To determine whether the quality of a low-volume reduced bowel preparation (LV-RBP) for CT Colonography (CTC) is noninferior to full-volume reduced bowel preparation (FV-RBP) regimen. METHODS In this randomized controlled trial, consecutive participants referred for CTC were randomly assigned to receive LV-RBP (52.5 g of PMF104 in 500 mL of water) or FV-RBP (105 g of PMF104 in 1000 mL of water). Images were independently reviewed by five blinded readers who rated the quality of bowel preparation from 0 (best score) to 3 (worst score). The primary outcome was the noninferiority of LV-RBP to FV-RBP in the proportion of colonic segments scored 0 for cleansing quality, with noninferiority margin of 10%. Volume of residual fluids, colonic distension, lesions and polyps detection rates and patient tolerability were secondary outcomes. RESULTS From March 2019 to January 2020, 110 participants (mean age 65 years ± 14 [standard deviation]; 74 women) were allocated to LV-RBP (n = 55) or FV-RBP (n = 55) arms. There were 92% segment scored 0 in colon cleansing quality in LV-RBP and 94% in FV-RBP for prone scans, and 94% vs 92% for supine scans. Risk difference was - 2.1 (95% CI -5.9 to 1.7) and 1.5 (95% CI -2.4 to 5.4) for prone and supine positions, respectively. Residual fluids and colonic distension were also noninferior in LV-RBP. LV-RBP was associated with a lower number of evacuations during preparation (7 ± 5 vs 10 ± 6, p = 0.002). CONCLUSION The LV-RBP for CTC demonstrated noninferior quality of colon cleansing with improved gastrointestinal tolerability compared to FV-RBP regimen.
Collapse
Affiliation(s)
- Davide Bellini
- Department of Radiological Sciences, Oncology and Pathology, Sapienza University of Rome - I.C.O.T. Hospital, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Nicola Panvini
- Department of Radiological Sciences, Oncology and Pathology, Sapienza University of Rome - I.C.O.T. Hospital, Via Franco Faggiana, 1668, 04100, Latina, Italy.
| | - Simone Vicini
- Department of Radiological Sciences, Oncology and Pathology, Sapienza University of Rome - I.C.O.T. Hospital, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Marco Rengo
- Department of Radiological Sciences, Oncology and Pathology, Sapienza University of Rome - I.C.O.T. Hospital, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Paola Lucchesi
- Department of Radiological Sciences, Oncology and Pathology, Sapienza University of Rome - I.C.O.T. Hospital, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Damiano Caruso
- Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy
| | - Iacopo Carbone
- Department of Radiological Sciences, Oncology and Pathology, Sapienza University of Rome - I.C.O.T. Hospital, Via Franco Faggiana, 1668, 04100, Latina, Italy
| | - Andrea Laghi
- Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy
| |
Collapse
|
5
|
Wu R, Geng L, Zhao Z, Liao D, He B, Hu H, Lin Y, Li M, Xiang M, Zhang Y, Feng G, Tan B, Du X. Clinical Application of Oral Meglumine Diatrizoate Esophagogram in Screening for Esophageal Fistula During Radiotherapy or Chemoradiotherapy for Esophageal Cancer. Front Oncol 2020; 10:562147. [PMID: 33123474 PMCID: PMC7566907 DOI: 10.3389/fonc.2020.562147] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 08/20/2020] [Indexed: 12/24/2022] Open
Abstract
Background: This study aimed to investigate the specificity and sensitivity of oral meglumine diatrizoate esophagogram in screening for esophageal fistula during radiotherapy or chemoradiotherapy for esophageal cancer and determine if early detection and intervention could improve the prognosis of esophageal fistulas. Methods: Esophageal cancer patients undergoing radiotherapy or chemoradiotherapy were included. Weekly oral meglumine diatrizoate esophagograms were performed to screen for esophageal fistulas during radiotherapy. When an esophageal fistula was detected, fibroesophagoscopy and computed tomography (CT) were used for confirmation; once confirmed, radiotherapy was discontinued, and the patient received intervention. The esophagogram results were reviewed weekly to assess the recovery of the esophageal fistula. If the fistula was healed, the patient resumed and completed radiotherapy. Results: A total of 206 patients with cancer of the esophagus undergoing chemotherapy/radiotherapy were included. During radiotherapy, 10 cases of esophageal fistula were detected or suspected based on the oral meglumine diatrizoate esophagography findings, and eight of those cases were confirmed by CT and esophagoscopy. All patients with esophageal fistula received intervention; among them, 62.5% (5/8) recovered after 1 to 2 weeks of treatment and continued radiotherapy to completion. The sensitivity and specificity of oral meglumine diatrizoate esophagography in screening for esophageal fistulas during radiotherapy or chemoradiotherapy were 100 and 98.9%, respectively. The median survival period of patients with esophageal fistulas was 6.4 months. Conclusion: Oral meglumine diatrizoate esophagography has high sensitivity and specificity in screening for esophageal fistulas during radiotherapy or chemoradiotherapy with minimal side effects. Early diagnosis and timely intervention can significantly improve the prognosis and prolong the survival period of patients. Trial Registration: Chictr.org.cn, Identifier: ChiCTR-DDD-17012617. Registered on September 7, 2017. The first participant was enrolled on September 25, 2017. http://www.chictr.org.cn/showproj.aspx?proj=21526.
Collapse
Affiliation(s)
- Rong Wu
- Department of Oncology, Mianyang Central Hospital, Mianyang, China
| | - Lidan Geng
- Department of Oncology, Mianyang Central Hospital, Mianyang, China.,Department of Oncology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Zhenhua Zhao
- Department of Oncology, Mianyang Central Hospital, Mianyang, China
| | - Dongbiao Liao
- Department of Oncology, Mianyang Central Hospital, Mianyang, China
| | - Bin He
- Department of Oncology, Yan Ting County Cancer Hospital, Yanting County, China
| | - He Hu
- Department of Oncology, Yan Ting County Cancer Hospital, Yanting County, China
| | - Yanqun Lin
- Department of Oncology, Yan Ting County Cancer Hospital, Yanting County, China
| | - Musheng Li
- Department of Radiology, Mianyang Cancer Hospital, Mianyang, China
| | - Miao Xiang
- Department of Oncology, Mianyang Central Hospital, Mianyang, China
| | - Yu Zhang
- Department of Oncology, Mianyang Central Hospital, Mianyang, China
| | - Gang Feng
- Department of Oncology, Mianyang Central Hospital, Mianyang, China
| | - Bangxian Tan
- Department of Oncology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Xiaobo Du
- Department of Oncology, Mianyang Central Hospital, Mianyang, China.,Department of Oncology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| |
Collapse
|
6
|
Chen LS, Hsu TW, Chen SJ, Chang SH, Lin CW, Chen YR, Hsieh CC, Han SC, Chang KY, Hou CJ. Improving Image Correlation and Differentiation of 3D Endoluminal Lesions in the Air Spaces Using a Novel Target Gray Level Mapping Technique: A Preliminary Study of Its Application to Computed Tomographic Colonography and Comparison with Traditional Surface Rendering Method. J Med Biol Eng 2020; 40:868-879. [PMID: 33013258 PMCID: PMC7519704 DOI: 10.1007/s40846-020-00565-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Accepted: 09/07/2020] [Indexed: 11/24/2022]
Abstract
Purpose To improve the three dimensional (3D) and two dimensional (2D) image correlation and differentiation of 3D endoluminal lesions in the traditional surface rendering (SR) computed tomographic endoscopy (CTE), a target gray level mapping (TGM) technique is developed and applied to computed tomographic colonography (CTC) in this study. Methods A study of sixty-two various endoluminal lesions from thirty patients (13 males, 17 females; age range 31–90 years) was approved by our institutional review board and evaluated retrospectively. The endoluminal lesions were segmented using gray level threshold. The marching cubes algorithm was used to detect isosurfaces in the segmented volumetric data sets. TGM allows users to interactively apply grey level mapping (GM) to region of interest (ROI) in the 3D CTC. Radiologists conducted the clinical evaluation and the resulting data were analyzed.
Results TGM and GM are significantly superior to SR in terms of surface texture, 3D shape, the confidence of 3D to 2D, 2D to 3D image correlation, and clinical classification of endoluminal lesions (P < 0.01). The specificity and diagnostic accuracy of GM and TGM methods are significantly better than those of SR (P < 0.01). Moreover, TGM performs better than GM (specificity: 75.0–85.7% vs. 53.6–64.3%; accuracy: 88.7–93.5% vs. 77.4–83.9%). TGM is a preferable display mode for further localization and differentiation of a lesion in CTC navigation.
Conclusions Compared with only the spatial shape information in traditional SR of CTC images, the 3D shapes and gray level information of endoluminal lesions can be provided by TGM simultaneously. 3D to 2D image correlations are also increased and facilitated at the same time. TGM is less affected by adjacent colon surfaces than GM. TGM serves as a better way to improve the image correlation and differentiation of endoluminal lesions.
Collapse
Affiliation(s)
- Lih-Shyang Chen
- Department of Electric Engineering, National Cheng Kung University, Tainan, Taiwan, ROC
| | - Ta-Wen Hsu
- Department of General Surgery, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC.,School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC
| | - Shao-Jer Chen
- School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC.,Department of Medical Imaging, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC.,Department of Medical Imaging, Buddhist Dalin Tzu Chi General Hospital, No. 2, Min-Sheng Road, Dalin Town, Chiayi, 622 Taiwan, ROC
| | - Shu-Han Chang
- Department of Electric Engineering, National Cheng Kung University, Tainan, Taiwan, ROC
| | - Chih-Wen Lin
- School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC.,Department of Medical Imaging, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC
| | - Yu-Ruei Chen
- School of Medicine, Tzu Chi University, Hualien, Taiwan, ROC.,Department of Medical Imaging, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan, ROC
| | - Chin-Chiang Hsieh
- Department of Radiology, Tainan Hospital, Ministry of Health and Welfare, Tainan, Taiwan, ROC
| | - Shu-Chen Han
- Department of Radiology, Tainan Municipal Hospital, Tainan, Taiwan, ROC
| | - Ku-Yaw Chang
- Department of Computer Science and Information Engineering, Da-Yeh University, Changhua, Taiwan, ROC
| | - Chun-Ju Hou
- Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan, Taiwan, ROC
| |
Collapse
|
7
|
Obmann MM, An C, Schaefer A, Sun Y, Wang ZJ, Yee J, Yeh BM. Improved Sensitivity and Reader Confidence in CT Colonography Using Dual-Layer Spectral CT: A Phantom Study. Radiology 2020; 297:99-107. [PMID: 32720868 DOI: 10.1148/radiol.2020200032] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Background Limited cathartic preparations for CT colonography with fecal tagging can improve patient comfort but may result in nondiagnostic examinations from poorly tagged stool. Dual-energy CT may overcome this limitation by improving the conspicuity of the contrast agent, but more data are needed. Purpose To investigate whether dual-energy CT improves polyp detection in CT colonography compared with conventional CT at different fecal tagging levels in vitro. Materials and Methods In this HIPAA-compliant study, between December 2017 and August 2019, a colon phantom 30 cm in diameter containing 60 polyps of different shapes (spherical, ellipsoid, flat) and size groups (5-9 mm, 11-15 mm) was constructed and serially filled with simulated feces tagged with four different iodine concentrations (1.26, 2.45, 4.88, and 21.00 mg of iodine per milliliter), then it was scanned with dual-energy CT with and without an outer fat ring to simulate large body size (total diameter, 42 cm). Two readers independently reviewed conventional 120-kVp CT and 40-keV monoenergetic dual-energy CT images to record the presence of polyps and confidence (three-point scale.) Generalized estimating equations were used for sensitivity comparisons between conventional CT and dual-energy CT, and a Wilcoxon signed-rank test was used for reader confidence. Results Dual-energy CT had higher overall sensitivity for polyp detection than conventional CT (58.8%; 95% confidence interval [CI]: 49.7%, 67.3%; 564 of 960 polyps vs 42.1%; 95% CI: 32.1%, 52.8%; 404 of 960 polyps; P < .001), including with the fat ring (48% and 31%, P < .001). Reader confidence improved with dual-energy CT compared with conventional images on all tagging levels (P < .001). Interrater agreement was substantial (κ = 0.74; 95% CI: 0.70, 0.77). Conclusion Compared with conventional 120-kVp CT, dual-energy CT improved polyp detection and reader confidence in a dedicated dual-energy CT colonography phantom, especially with suboptimal fecal tagging. © RSNA, 2020.
Collapse
Affiliation(s)
- Markus M Obmann
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, San Francisco, CA 94117 (M.M.O., C.A., A.S., Y.S., Z.J.W., B.M.Y.); and Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY (J.Y.)
| | - Chansik An
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, San Francisco, CA 94117 (M.M.O., C.A., A.S., Y.S., Z.J.W., B.M.Y.); and Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY (J.Y.)
| | - Amanda Schaefer
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, San Francisco, CA 94117 (M.M.O., C.A., A.S., Y.S., Z.J.W., B.M.Y.); and Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY (J.Y.)
| | - Yuxin Sun
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, San Francisco, CA 94117 (M.M.O., C.A., A.S., Y.S., Z.J.W., B.M.Y.); and Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY (J.Y.)
| | - Zhen J Wang
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, San Francisco, CA 94117 (M.M.O., C.A., A.S., Y.S., Z.J.W., B.M.Y.); and Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY (J.Y.)
| | - Judy Yee
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, San Francisco, CA 94117 (M.M.O., C.A., A.S., Y.S., Z.J.W., B.M.Y.); and Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY (J.Y.)
| | - Benjamin M Yeh
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, San Francisco, CA 94117 (M.M.O., C.A., A.S., Y.S., Z.J.W., B.M.Y.); and Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, New York, NY (J.Y.)
| |
Collapse
|
8
|
Ricci ZJ, Kobi M, Flusberg M, Yee J. CT Colonography in Review With Tips and Tricks to Improve Performance. Semin Roentgenol 2020; 56:140-151. [PMID: 33858640 DOI: 10.1053/j.ro.2020.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Zina J Ricci
- Montefiore Medical Center/Albert Einstein College of Medicine, Bronx, NY.
| | - Mariya Kobi
- Montefiore Medical Center/Albert Einstein College of Medicine, Bronx, NY
| | - Milana Flusberg
- Westchester Medical Center/New York Medical College, Valhalla, NY
| | - Judy Yee
- Montefiore Medical Center/Albert Einstein College of Medicine, Bronx, NY
| |
Collapse
|
9
|
O’Shea A, Foran AT, Murray TE, Thornton E, Dunne R, Lee MJ, Morrin MM. Quality of same-day CT colonography following incomplete optical colonoscopy. Eur Radiol 2020; 30:6508-6516. [DOI: 10.1007/s00330-020-06979-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 04/17/2020] [Accepted: 05/25/2020] [Indexed: 01/25/2023]
|
10
|
Utano K, Takayanagi D, Nagata K, Aizawa M, Endo S, Nemoto T, Nemoto D, Isohata N, Lefor AK, Togashi K. A novel volume-reduced CT colonography regimen using hypertonic laxative (polyethylene glycol with ascorbic acid): randomized controlled trial. Eur Radiol 2019; 29:5236-5246. [PMID: 30903329 DOI: 10.1007/s00330-019-06127-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Revised: 02/10/2019] [Accepted: 02/25/2019] [Indexed: 12/17/2022]
Abstract
OBJECTIVES The aim of this study is to investigate the feasibility of bowel preparation using a hypertonic laxative (polyethylene glycol with ascorbic acid, PEG + Asc) for CT colonography (CTC) and to examine the volume limit of laxative. METHODS In one institution, patients who met the indications for CTC were enrolled and randomly assigned to CTC with regimen A (800 ml PEG + Asc), B (600 ml PEG + Asc), or C (400 ml PEG + Asc). Sodium diatrizoate was given orally for fecal tagging. On the previous day, patients ate low-residue meals and took the assigned lavage solution after dinner. A reader blinded to the preparation graded residual stool/fluid and fecal tagging quality in six segments of the colorectum. The primary outcome was a proportion of colon segments without stool. One hundred twenty segments in 20 patients with each regimen were needed to show a non-inferiority margin of 15%, assuming 85% of no stool. RESULTS A total of 360 segments in 60 patients were analyzed. There were 83% of segments with no stool in regimen A, 89% in regimen B, and 88% in regimen C. Using the delta method, the 95% confidence interval of the risk difference (6.7%) between regimens A and B was - 2.2% to 15.6%, and the risk difference (5.0%) between regimens A and C was - 4.1% to 14%, both within the non-inferiority margin. Residual fluid and fecal tagging quality were also within the non-inferiority margin. No adverse events occurred. CONCLUSIONS A novel CTC regimen using hypertonic laxative demonstrated optimal colon cleansing effectiveness even with the lowest volume of laxative (UMIN000022851). KEY POINTS • A novel CTC regimen using a hypertonic laxative is feasible. • The lowest volume of laxative provides excellent colon imaging. • However, the lowest volume of laxative did not improve patient acceptance.
Collapse
Affiliation(s)
- Kenichi Utano
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan
| | - Daisuke Takayanagi
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan
| | - Koichi Nagata
- Division of Screening Technology, National Cancer Center, Tokyo, Japan
| | - Masato Aizawa
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan
| | - Shungo Endo
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan
| | - Tetsutaro Nemoto
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan
| | - Daiki Nemoto
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan
| | - Noriyuki Isohata
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan
| | - Alan Kawarai Lefor
- Department of Surgery, Jichi Medical University, Shimotsuke, Tochigi, Japan
| | - Kazutomo Togashi
- Department of Coloproctology, Aizu Medical Center, Fukushima Medical University, 21-2 Maeda, Tanisawa, Kawahigashi, Aizuwakamatsu City, Fukushima, 969-3492, Japan.
| |
Collapse
|
11
|
Mitsuzaki K, Iinuma G, Morimoto T, Miyake M, Tomimatsu H. Computed tomographic colonography with a reduced dose of laxative using a novel barium sulfate contrast agent in Japan. Jpn J Radiol 2018; 37:245-254. [PMID: 30554302 DOI: 10.1007/s11604-018-0800-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 12/09/2018] [Indexed: 01/22/2023]
Abstract
PURPOSE To test the tagging efficacy, patient acceptability, and accuracy of computed tomographic colonography (CTC) with a reduced dose of laxative using a novel barium sulfate (BaSO4) contrast agent. MATERIALS AND METHODS CTC followed by optical colonoscopy (OC) was performed on 73 patients with positive results in fecal occult blood tests. They were administrated a BaSO4 suspension and a magnesium citrate solution for bowel preparation. Patients completed a questionnaire about the acceptability of bowel preparation. Tagging efficacy was estimated using a novel categorization system, which classified all segments into 8 categories. The accuracy of detecting protruded lesions ≥ 6 mm was calculated from the comparison of CTC and OC results, using the latter as a reference standard. RESULTS Tagging efficacy was good in 77.3% of colonic segments where residue was observed. The acceptability of bowel preparation for CTC was significantly higher than that for OC. The sensitivity, specificity, and positive and negative predictive values were 0.778, 0.945, 0.824, and 0.929, respectively. All lesions ≥ 7 mm were successfully detected by CTC. CONCLUSION CTC with a reduced dose of laxative using a novel BaSO4 contrast agent has a favorable tagging efficacy, patient acceptability, and accuracy.
Collapse
Affiliation(s)
- Katsuhiko Mitsuzaki
- Center for Preventive Medicine, Saiseikai Kumamoto Hospital, 5-3-1 Chikami, Minami-ku, Kumamoto, Kumamoto, Japan.
| | - Gen Iinuma
- Department of Radiology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, Japan
| | - Tsuyoshi Morimoto
- Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa, Japan
| | - Mototaka Miyake
- Department of Radiology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, Japan
| | - Hideto Tomimatsu
- Department of Radiology, Gifu University School of Medicine, 1-1 Yanagito, Gifu, Gifu, Japan
| |
Collapse
|
12
|
Taguchi N, Oda S, Imuta M, Yamamura S, Yokota Y, Nakaura T, Nagayama Y, Kidoh M, Utsunomiya D, Funama Y, Baba H, Yamashita Y. Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing. Eur J Radiol 2018; 108:7-12. [PMID: 30396674 DOI: 10.1016/j.ejrad.2018.09.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 07/31/2018] [Accepted: 09/10/2018] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To assess the utility of virtual monochromatic imaging (VMI) using a dual-layer spectral detector CT for electronic cleansing in fecal-tagging CT colonography (CTC). METHODS This study included 35 patients who underwent fecal-tagging CTC with a dual-layer detector spectral CT scanner. Conventional images at 120 kVp and VMI at 40, 50, and 60 keV were reconstructed. Quantitative image quality parameters, i.e., tagging density and image noise, were compared and the visual image quality was scored on a four-point scale. We recorded the number of the colon segments with appropriate tagging density (≥300 HU) for each patient and used these data to compare the reconstructions. In addition, electronic cleansing performance was semi-quantitatively assessed using a four-point scale. RESULTS The mean tagging density on VMI was significantly higher than that on conventional 120 kVp images. The number of colon segments with appropriate tagging density on VMI were significantly higher than that on conventional 120 kVp images. There was no significant difference among the reconstructed images with respect to image noise. Scores for subjective image quality and electronic cleansing performance on VMI were significantly higher than those on conventional 120 kVp images. CONCLUSION With dual-layer spectral detector CT, VMI can yield significantly better fecal-tagged CTC image quality and improve electronic cleansing performance.
Collapse
Affiliation(s)
- Narumi Taguchi
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Seitaro Oda
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan.
| | - Masanori Imuta
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Sadahiro Yamamura
- Department of Radiology, Kumamoto General Hospital, 10-10 Toricho, Yatsushiro, Kumamoto, 866-8660, Japan
| | - Yasuhiro Yokota
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yasunori Nagayama
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Masafumi Kidoh
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Daisuke Utsunomiya
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Hideo Baba
- Department of Gastroenterological Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| |
Collapse
|
13
|
Patients’ experience of screening CT colonography with reduced and full bowel preparation in a randomised trial. Eur Radiol 2018; 29:2457-2464. [DOI: 10.1007/s00330-018-5808-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 09/10/2018] [Accepted: 09/27/2018] [Indexed: 02/07/2023]
|
14
|
van der Meulen MP, Lansdorp-Vogelaar I, Goede SL, Kuipers EJ, Dekker E, Stoker J, van Ballegooijen M. Colorectal Cancer: Cost-effectiveness of Colonoscopy versus CT Colonography Screening with Participation Rates and Costs. Radiology 2018; 287:901-911. [PMID: 29485322 DOI: 10.1148/radiol.2017162359] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Purpose To compare the cost-effectiveness of computed tomographic (CT) colonography and colonoscopy screening by using data on unit costs and participation rates from a randomized controlled screening trial in a dedicated screening setting. Materials and Methods Observed participation rates and screening costs from the Colonoscopy or Colonography for Screening, or COCOS, trial were used in a microsimulation model to estimate costs and quality-adjusted life-years (QALYs) gained with colonoscopy and CT colonography screening. For both tests, the authors determined optimal age range and screening interval combinations assuming a 100% participation rate. Assuming observed participation for these combinations, the cost-effectiveness of both tests was compared. Extracolonic findings were not included because long-term follow-up data are lacking. Results The participation rates for colonoscopy and CT colonography were 21.5% (1276 of 5924 invitees) and 33.6% (982 of 2920 invitees), respectively. Colonoscopy was more cost-effective in the screening strategies with one or two lifetime screenings, whereas CT colonography was more cost-effective in strategies with more lifetime screenings. CT colonography was the preferred test for willingness-to-pay-thresholds of €3200 per QALY gained and higher, which is lower than the Dutch willingness-to-pay threshold of €20 000. With equal participation, colonoscopy was the preferred test independent of willingness-to-pay thresholds. The findings were robust for most of the sensitivity analyses, except with regard to relative screening costs and subsequent participation. Conclusion Because of the higher participation rates, CT colonography screening for colorectal cancer is more cost-effective than colonoscopy screening. The implementation of CT colonography screening requires previous satisfactory resolution to the question as to how best to deal with extracolonic findings. © RSNA, 2018 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Miriam P van der Meulen
- From the Departments of Public Health (M.P.v.d.M., I.L.V., S.L.G., M.v.B.), Gastroenterology and Hepatology (E.J.K.), and Internal Medicine (E.J.K.), Erasmus Medical Centre, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology (E.D.) and Department of Radiology (J.S.), Academic Medical Center, Amsterdam, the Netherlands
| | - Iris Lansdorp-Vogelaar
- From the Departments of Public Health (M.P.v.d.M., I.L.V., S.L.G., M.v.B.), Gastroenterology and Hepatology (E.J.K.), and Internal Medicine (E.J.K.), Erasmus Medical Centre, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology (E.D.) and Department of Radiology (J.S.), Academic Medical Center, Amsterdam, the Netherlands
| | - S Lucas Goede
- From the Departments of Public Health (M.P.v.d.M., I.L.V., S.L.G., M.v.B.), Gastroenterology and Hepatology (E.J.K.), and Internal Medicine (E.J.K.), Erasmus Medical Centre, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology (E.D.) and Department of Radiology (J.S.), Academic Medical Center, Amsterdam, the Netherlands
| | - Ernst J Kuipers
- From the Departments of Public Health (M.P.v.d.M., I.L.V., S.L.G., M.v.B.), Gastroenterology and Hepatology (E.J.K.), and Internal Medicine (E.J.K.), Erasmus Medical Centre, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology (E.D.) and Department of Radiology (J.S.), Academic Medical Center, Amsterdam, the Netherlands
| | - Evelien Dekker
- From the Departments of Public Health (M.P.v.d.M., I.L.V., S.L.G., M.v.B.), Gastroenterology and Hepatology (E.J.K.), and Internal Medicine (E.J.K.), Erasmus Medical Centre, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology (E.D.) and Department of Radiology (J.S.), Academic Medical Center, Amsterdam, the Netherlands
| | - Jaap Stoker
- From the Departments of Public Health (M.P.v.d.M., I.L.V., S.L.G., M.v.B.), Gastroenterology and Hepatology (E.J.K.), and Internal Medicine (E.J.K.), Erasmus Medical Centre, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology (E.D.) and Department of Radiology (J.S.), Academic Medical Center, Amsterdam, the Netherlands
| | - Marjolein van Ballegooijen
- From the Departments of Public Health (M.P.v.d.M., I.L.V., S.L.G., M.v.B.), Gastroenterology and Hepatology (E.J.K.), and Internal Medicine (E.J.K.), Erasmus Medical Centre, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, the Netherlands; Department of Gastroenterology and Hepatology (E.D.) and Department of Radiology (J.S.), Academic Medical Center, Amsterdam, the Netherlands
| |
Collapse
|
15
|
Regge D, Iussich G, Segnan N, Correale L, Hassan C, Arrigoni A, Asnaghi R, Bestagini P, Bulighin G, Cassinis MC, Ederle A, Ferraris A, Galatola G, Gallo T, Gandini G, Garretti L, Martina MC, Molinar D, Montemezzi S, Morra L, Motton M, Occhipinti P, Pinali L, Soardi GA, Senore C. Comparing CT colonography and flexible sigmoidoscopy: a randomised trial within a population-based screening programme. Gut 2017; 66:1434-1440. [PMID: 27196588 DOI: 10.1136/gutjnl-2015-311278] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Revised: 03/17/2016] [Accepted: 03/21/2016] [Indexed: 12/16/2022]
Abstract
IMPORTANCE AND AIMS The role of CT colonography (CTC) as a colorectal cancer (CRC) screening test is uncertain. The aim of our trial was to compare participation and detection rate (DR) with sigmoidoscopy (flexible sigmoidoscopy (FS)) and CTC in a screening setting. DESIGN SETTING AND PARTICIPANTS We conducted two randomised clinical trials (RCTs). (1) Participation RCT: individuals, aged 58 years, living in Turin (Italy), were randomly assigned to be invited to FS or CTC screening; (2) detection RCT: residents in northern Italy, aged 58-60, giving their consent to recruitment, were randomly allocated to CTC or FS. Polyps ≥6 mm at CTC, or 'high-risk' distal lesions at FS, were referred for colonoscopy (TC). MAIN OUTCOME MEASURES Participation rate (proportion of invitees examined); DR of advanced adenomas or CRC (advanced neoplasia (AN)). RESULTS Participation was 30.4% (298/980) for CTC and 27.4% (267/976) for FS (relative risk (RR) 1.1; 95% CI 0.98 to 1.29). Among men, participation was higher with CTC than with FS (34.1% vs 26.5%, p=0.011). In the detection RCT, 2673 subjects had FS and 2595 had CTC: the AN DR was 4.8% (127/2673, including 9 CRCs) with FS and 5.1% (133/2595, including 10 CRCs) with CTC (RR 1.08; 95% CI 0.85 to 1.37). Distal AN DR was 3.9% (109/2673) with FS and 2.9% (76/2595) with CTC (RR 0.72; 95% CI 0.54 to 0.96); proximal AN DR was 1.2% (34/2595) for FS vs 2.7% (69/2595) for CTC (RR 2.06; 95% CI 1.37 to 3.10). CONCLUSIONS AND RELEVANCE Participation and DR for FS and CTC were comparable. AN DR was twice as high in the proximal colon and lower in the distal colon with CTC than with FS. Men were more likely to participate in CTC screening. TRIAL REGISTRATION NUMBER NCT01739608; Pre-results.
Collapse
Affiliation(s)
- Daniele Regge
- Candiolo Cancer Institute-FPO, IRCCS, Candiolo, Italy
| | | | - Nereo Segnan
- AOU S Giovanni Battista-CPO Piemonte, SCDO Epidemiologia dei Tumori 2, Turin, Italy
| | - Loredana Correale
- im3D S.p.A., Turin, Italy
- Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy
| | - Cesare Hassan
- AOU Città della Salute e della Scienza, CPO Piemonte, SCDO Epidemiologia screening e registro tumori, Turin, Italy
| | - Arrigo Arrigoni
- Endoscopy Unit, Ospedale San Giovanni Antica Sede, Turin, Italy
| | - Roberto Asnaghi
- Radiology Unit, Fondazione Salvatore Maugeri, IRCCS, Istituto Scientifico di Veruno, Veruno, Italy
| | | | - Gianmarco Bulighin
- Endoscopy and Gastroenterology Unit, U.l.s.s. 20 Verona, Ospedale G. Fracastoro-San Bonifacio, Verona, Italy
| | - Maria Carla Cassinis
- Radiology Unit, Department of Surgical Science, University of Torino, A.O.U. Città della Salute e della Scienza di Torino, Turin, Italy
| | - Andrea Ederle
- Endoscopy and Gastroenterology Unit, U.l.s.s. 20 Verona, Ospedale G. Fracastoro-San Bonifacio, Verona, Italy
| | - Andrea Ferraris
- Radiology Unit, Department of Surgical Science, University of Torino, A.O.U. Città della Salute e della Scienza di Torino, Turin, Italy
| | | | - Teresa Gallo
- Radiology Unit, Ospitale Mauriziano, Turin, Italy
| | - Giovanni Gandini
- Radiology Unit, Department of Surgical Science, University of Torino, A.O.U. Città della Salute e della Scienza di Torino, Turin, Italy
| | - Licia Garretti
- Radiology Unit, Ospedale San Giovanni Antica Sede, Turin, Italy
| | - Maria Cristina Martina
- Radiology Unit, Department of Surgical Science, University of Torino, A.O.U. Città della Salute e della Scienza di Torino, Turin, Italy
| | | | - Stefania Montemezzi
- Radiology Unit, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Lia Morra
- im3D S.p.A., Turin, Italy
- Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy
| | - Massimiliano Motton
- Radiology Unit, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | | | - Lucia Pinali
- Radiology Unit, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Gian Alberto Soardi
- Radiology Unit, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Carlo Senore
- AOU S Giovanni Battista-CPO Piemonte, SCDO Epidemiologia dei Tumori 2, Turin, Italy
| |
Collapse
|
16
|
Sali L, Grazzini G, Mascalchi M. CT colonography: role in FOBT-based screening programs for colorectal cancer. Clin J Gastroenterol 2017; 10:312-319. [PMID: 28447326 DOI: 10.1007/s12328-017-0744-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 04/18/2017] [Indexed: 01/28/2023]
Abstract
Computed tomographic colonography (CTC) is a minimally invasive imaging examination for the colon, and is safe, well tolerated and accurate for the detection of colorectal cancer (CRC) and advanced adenoma. While the role of CTC as a primary test for population screening of CRC is under investigation, the fecal occult blood test (FOBT) has been recommended for population screening of CRC in Europe. Subjects with positive FOBT are invited to undergo total colonoscopy, which has some critical issues, such as suboptimal compliance, contraindications and the possibility of an incomplete exploration of the colon. Based on available data, the integration of CTC in FOBT-based population screening programs for CRC may fall into three scenarios. First, CTC is recommended in FOBT-positive subjects when colonoscopy is refused, incomplete or contraindicated. For these indications CTC should replace double-contrast barium enema. Second, conversely, CTC is not currently recommended as a second-level examination prior to colonoscopy in all FOBT-positive subjects, as this strategy is most probably not cost-effective. Finally, CTC may be considered instead of colonoscopy for surveillance after adenoma removal, but specific studies are needed.
Collapse
Affiliation(s)
- Lapo Sali
- Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", University of Florence, Viale Morgagni 50, 50134, Florence, Italy.
| | - Grazia Grazzini
- Cancer Prevention and Research Institute (ISPO), Via Cosimo il Vecchio 2, 50139, Florence, Italy
| | - Mario Mascalchi
- Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", University of Florence, Viale Morgagni 50, 50134, Florence, Italy
| |
Collapse
|
17
|
Steffey MA, Zwingenberger AL, Daniel L, Taylor SL. Assessment of 3 Bowel Preparation Protocols for Computed Tomography Pneumocolonography in Normal Dogs. Vet Surg 2016; 45:929-935. [PMID: 27489142 DOI: 10.1111/vsu.12524] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To investigate the effects of 3 different bowel preparation protocols on interpretation of computed tomography (CT) pneumocolonography images. STUDY DESIGN Experimental crossover design. ANIMALS Intact male, hound-cross, research colony dogs (n=4). METHODS All dogs received the 3 different bowel preparation protocols for CT pneumocolonography in the same order, with a minimum of 2 weeks between protocols. For each segment of large bowel, the subjective adequacy of bowel cleansing was assessed, residual fecal and bowel volumes were calculated, and the density of fecal material in the bowel lumen was measured. Linear mixed effect models that included a random dog effect were used to evaluate mean differences in outcome measures across protocols. RESULTS No dogs experienced any clinical problems associated with the protocols or CT pneumocolonography. Bowel cleansing was considered adequate for CT pneumocolonography interpretation for all 3 protocols. There was a significant effect of protocol on residual fecal volumes and the fecal:bowel volume ratio, with the 2 protocols that included an extended fast producing the lowest total residual fecal volumes. There was a significant effect of protocol on maximum measured density of residual fecal material with the 2 protocols including iodinated contrast having the highest density. CONCLUSIONS All protocols were sufficient for CT pneumocolonography interpretation and contrast-tagging of residual fecal material was successful with oral iopamidol administration. An at-home bowel cleansing protocol may provide adequate bowel cleansing for CT pneumocolonography image interpretation.
Collapse
Affiliation(s)
- Michele A Steffey
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, California.
| | - Allison L Zwingenberger
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, California
| | - Leticia Daniel
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, California
| | - Sandra L Taylor
- Department of Public Health Sciences, Division of Biostatistics, School of Medicine, University of California-Davis, Davis, California
| |
Collapse
|
18
|
Fuster D, Pagès M, Granados U, Perlaza P, Rubello D, Lomeña F. Update on PET/CT colonography in the diagnosis of colorectal cancer. Rev Esp Med Nucl Imagen Mol 2016; 35:246-52. [DOI: 10.1016/j.remn.2016.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Revised: 05/02/2016] [Accepted: 05/03/2016] [Indexed: 12/23/2022]
|
19
|
Fuster D, Pagès M, Granados U, Perlaza P, Rubello D, Lomeña F. Update on PET/CT colonography in the diagnosis of colorectal cancer. Rev Esp Med Nucl Imagen Mol 2016. [DOI: 10.1016/j.remnie.2016.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
20
|
Greuter MJE, Berkhof J, Fijneman RJA, Demirel E, Lew JB, Meijer GA, Stoker J, Coupé VMH. The potential of imaging techniques as a screening tool for colorectal cancer: a cost-effectiveness analysis. Br J Radiol 2016; 89:20150910. [PMID: 27194458 DOI: 10.1259/bjr.20150910] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
OBJECTIVE Imaging may be promising for colorectal cancer (CRC) screening, since it has test characteristics comparable with colonoscopy but is less invasive. We aimed to assess the potential of CT colonography (CTC) and MR colonography (MRC) in terms of (cost-effectiveness) using the Adenoma and Serrated pathway to Colorectal CAncer model. METHODS We compared several CTC and MRC strategies with 5- or 10-yearly screening intervals with no screening, 10-yearly colonoscopy screening and biennial faecal immunochemical test (FIT) screening. We assumed trial-based participation rates in the base-case analyses and varied the rates in sensitivity analyses. Incremental lifetime costs and health effects were estimated from a healthcare perspective. RESULTS The health gain of CTC and MRC was similar and ranged from 0.031 to 0.048 life-year gained compared with no screening, for 2-5 screening rounds. Lifetime costs per person for MRC strategies were €60-110 higher than those for CTC strategies with an equal number of screening rounds. All imaging-based strategies were cost-effective compared with no screening. FIT screening was the dominant screening strategy, leading to most LYG and highest cost-savings. Compared with three rounds of colonoscopy screening, CTC with five rounds was found to be cost-effective in an incremental analysis of imaging strategies. Assumptions on screening participation have a major influence on the ordering of strategies in terms of costs and effects. CONCLUSION CTC and MRC have potential for CRC screening, compared with no screening and compared with three rounds of 10-yearly colonoscopy screening. When taking FIT screening as the reference, imaging is not cost-effective. Participation is an important driver of effectiveness and cost estimates. ADVANCES IN KNOWLEDGE This is the first study to assess the cost-effectiveness of MRC screening for CRC.
Collapse
Affiliation(s)
- Marjolein J E Greuter
- 1 Department of Epidemiology and Biostatistics, VU University Medical Center, Amsterdam, Netherlands
| | - Johannes Berkhof
- 1 Department of Epidemiology and Biostatistics, VU University Medical Center, Amsterdam, Netherlands
| | - Remond J A Fijneman
- 2 Department of Pathology, Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Erhan Demirel
- 1 Department of Epidemiology and Biostatistics, VU University Medical Center, Amsterdam, Netherlands
| | - Jie-Bin Lew
- 3 Cancer Research Division, Cancer Council NSW, NSW, Australia
| | - Gerrit A Meijer
- 2 Department of Pathology, Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Jaap Stoker
- 4 Department of Radiology, Academic Medical Center, Amsterdam, Netherlands
| | - Veerle M H Coupé
- 1 Department of Epidemiology and Biostatistics, VU University Medical Center, Amsterdam, Netherlands
| |
Collapse
|
21
|
Neri E, Mantarro A, Faggioni L, Scalise P, Bemi P, Pancrazi F, D'Ippolito G, Bartolozzi C. CT colonography with rectal iodine tagging: Feasibility and comparison with oral tagging in a colorectal cancer screening population. Eur J Radiol 2015; 84:1701-7. [PMID: 26032131 DOI: 10.1016/j.ejrad.2015.05.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Revised: 05/11/2015] [Accepted: 05/18/2015] [Indexed: 02/06/2023]
Abstract
PURPOSE To evaluate feasibility, diagnostic performance, patient acceptance, and overall examination time of CT colonography (CTC) performed through rectal administration of iodinated contrast material. MATERIALS AND METHODS Six-hundred asymptomatic subjects (male:female=270:330; mean 63 years) undergoing CTC for colorectal cancer screening on an individual basis were consecutively enrolled in the study. Out of them, 503 patients (group 1) underwent CTC with rectal tagging, of which 55 had a total of 77 colonic lesions. The remaining 97 patients (group 2) were randomly selected to receive CTC with oral tagging of which 15 had a total of 20 colonic lesions. CTC findings were compared with optical colonoscopy, and per-segment image quality was visually assessed using a semi-quantitative score (1=poor, 2=adequate, 3=excellent). In 70/600 patients (11.7%), CTC was performed twice with both types of tagging over a 5-year follow-up cancer screening program. In this subgroup, patient acceptance was rated via phone interview two weeks after CTC using a semi-quantitative scale (1=poor, 2=fair, 3=average, 4=good, 5=excellent). RESULTS Mean per-polyp sensitivity, specificity, positive and negative predictive values of CTC with rectal vs oral tagging were 96.1% (CI95% 85.4÷99.3%) vs 89.4% (CI95% 65.4÷98.1%), 95.3% (CI95% 90.7÷97.8%) vs 95.8% (CI95% 87.6÷98.9%), 86.0% (CI95% 73.6÷93.3) vs 85.0% (CI95% 61.1÷96.0%), and 98.8% (CI95% 95.3÷99.8%) vs 97.2% (CI95% 89.4÷99.5%), respectively (p>0.05). Polyp detection rates were not statistically different between groups 1 and 2 (p>0.05). Overall examination time was significantly shorter with rectal than with oral tagging (18.3±3.5 vs 215.6±10.3 minutes, respectively; p<0.0001). CONCLUSIONS Rectal iodine tagging can be an effective alternative to oral tagging for CTC with the advantages of greater patient acceptance and lower overall examination time.
Collapse
Affiliation(s)
- Emanuele Neri
- Diagnostic and Interventional Radiology - Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Italy.
| | - Annalisa Mantarro
- Diagnostic and Interventional Radiology - Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Italy
| | - Lorenzo Faggioni
- Diagnostic and Interventional Radiology - Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Italy
| | - Paola Scalise
- Diagnostic and Interventional Radiology - Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Italy
| | - Pietro Bemi
- Diagnostic and Interventional Radiology - Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Italy
| | - Francesca Pancrazi
- Diagnostic and Interventional Radiology - Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Italy
| | - Giuseppe D'Ippolito
- Federal University of São Paulo - Sena Madureira 1500 - Vila Mariana, UNIFESP, São Paulo, SP, Brazil
| | - Carlo Bartolozzi
- Diagnostic and Interventional Radiology - Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Italy
| |
Collapse
|
22
|
Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography. Eur Radiol 2015; 25:2115-24. [DOI: 10.1007/s00330-015-3604-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 10/30/2014] [Accepted: 01/15/2015] [Indexed: 01/15/2023]
|
23
|
Laghi A. Computed tomography colonography in 2014: an update on technique and indications. World J Gastroenterol 2014; 20:16858-67. [PMID: 25492999 PMCID: PMC4258555 DOI: 10.3748/wjg.v20.i45.16858] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2014] [Revised: 08/27/2014] [Accepted: 10/14/2014] [Indexed: 02/06/2023] Open
Abstract
Twenty years after its introduction, computed tomographic colonography (CTC) has reached its maturity, and it can reasonably be considered the best radiological diagnostic test for imaging colorectal cancer (CRC) and polyps. This examination technique is less invasive than colonoscopy (CS), easy to perform, and standardized. Reduced bowel preparation and colonic distention using carbon dioxide favor patient compliance. Widespread implementation of a new image reconstruction algorithm has minimized radiation exposure, and the use of dedicated software with enhanced views has enabled easier image interpretation. Integration in the routine workflow of a computer-aided detection algorithm reduces perceptual errors, particularly for small polyps. Consolidated evidence from the literature shows that the diagnostic performances for the detection of CRC and large polyps in symptomatic and asymptomatic individuals are similar to CS and are largely superior to barium enema, the latter of which should be strongly discouraged. Favorable data regarding CTC performance open the possibility for many different indications, some of which are already supported by evidence-based data: incomplete, failed, or unfeasible CS; symptomatic, elderly, and frail patients; and investigation of diverticular disease. Other indications are still being debated and, thus, are recommended only if CS is unfeasible: the use of CTC in CRC screening and in surveillance after surgery for CRC or polypectomy. In order for CTC to be used appropriately, contraindications such as acute abdominal conditions (diverticulitis or the acute phase of inflammatory bowel diseases) and surveillance in patients with a long-standing history of ulcerative colitis or Crohn's disease and in those with hereditary colonic syndromes should not be overlooked. This will maximize the benefits of the technique and minimize potential sources of frustration or disappointment for both referring clinicians and patients.
Collapse
|
24
|
Iafrate F, Iannitti M, Ciolina M, Baldassari P, Pichi A, Laghi A. Bowel cleansing before CT colonography: comparison between two minimal-preparation regimens. Eur Radiol 2014; 25:203-10. [PMID: 25149295 DOI: 10.1007/s00330-014-3345-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2014] [Revised: 05/20/2014] [Accepted: 07/14/2014] [Indexed: 01/27/2023]
Abstract
AIM To compare two regimens of reduced bowel preparation and faecal tagging for CT colonography. MATERIALS AND METHODS Single centre, prospective, randomized, noninferiority study, in which 52 consecutive adults underwent routine CT colonography. Patients, following a three-day low-fibre diet, received one of the two reduced preparations: 1-L polyethylene glycol and four tablets of bisacodyl in association with 90 mL of Iopamidol for faecal tagging administered on the same day as CTC examination (group 1); or a standard "iodine-only" preparation, consisting in 180 ml of Iopamidol the day before the examination (group 2). Primary outcome was the overall quality of bowel preparation. RESULTS Twenty-six patients per group were included. Per segment analysis showed preparation of diagnostic quality in 97.4% of segments in group 1 and in 95.5% in group 2 (p = ns). Per-patient analysis showed optimal quality of preparation in 76.9% of patients in group 1 and in 84.6% in group 2 (p = ns). Patient tolerability to both preparations was not different. CONCLUSION A limited bowel preparation consisting of 1-L PEG and four tablets of bisacodyl in association with 90 mL of Iodine for faecal tagging administered on the same day as CTC examination is feasible and offers bowel cleansing comparable to "iodine-only" preparation. KEY POINTS • Low-dose PEG bisacodyl and Iopamidol preparation is feasible, providing adequate bowel cleansing. • Faecal tagging is not different from the two limited preparations. • Patient tolerability to the two colon cleansing regimens is similar.
Collapse
Affiliation(s)
- F Iafrate
- Department of Radiological Oncological and Pathological Sciences, "Sapienza" University of Rome, Rome, Italy,
| | | | | | | | | | | |
Collapse
|
25
|
Noncathartic CT colonography: Image quality assessment and performance and in a screening cohort. AJR Am J Roentgenol 2013; 201:787-94. [PMID: 24059367 DOI: 10.2214/ajr.12.9225] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE Cathartic bowel preparation is a major barrier for colorectal cancer screening. We examined noncathartic CT colonography (CTC) quality and performance using four similar bowel-tagging regimens in an asymptomatic screening cohort. SUBJECTS AND METHODS This prospective study included 564 asymptomatic subjects who underwent noncathartic CTC without dietary modification but with 21 g of barium with or without iodinated oral contrast material (four regimens). The quality of tagging with oral agents was evaluated. A gastrointestinal radiologist evaluated examinations using primary 2D search supplemented by electronic cleansing (EC) and 3D problem solving. Results were compared with complete colonoscopy findings after bowel purgation and with retrospective unblinded evaluation in 556 of the 564 (99%) subjects. RESULTS Of the 556 subjects, 7% (37/556) and 3% (16/556) of patients had 52 and 20 adenomatous polyps ≥ 6 and ≥ 10 mm, respectively. The addition of iodine significantly improved the percentage of labeled stool (p ≤ 0.0002) and specificity (80% vs 89-93%, respectively; p = 0.046). The overall sensitivity of noncathartic CTC for adenomatous polyps ≥ 6 mm was 76% (28/37; 95% CI, 59-88%), which is similar to the sensitivity of the iodinated regimens with most patients (sensitivity: 231 patients, 74% [14/19; 95% CI, 49-91%]; 229 patients, 80% [12/15; 95% CI, 52-96%]). The negative predictive value was 98% (481/490), and the lone cancer was detected (0.2%, 1/556). EC was thought to improve conspicuity of 10 of 21 visible polyps ≥ 10 mm. CONCLUSION In this prospective study of asymptomatic subjects, the per-patient sensitivity of noncathartic CTC for detecting adenomas ≥ 6 mm was approximately 76%. Inclusion of oral iodine contrast material improves examination specificity and the percentage of labeled stool. EC may improve polyp conspicuity.
Collapse
|
26
|
Hansmann A, Burling D. Essential requirements of a CT colonography service. Eur J Radiol 2013; 82:1187-91. [DOI: 10.1016/j.ejrad.2012.03.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Revised: 03/07/2012] [Accepted: 03/08/2012] [Indexed: 12/20/2022]
|
27
|
Pollentine A, Ngan-Soo E, McCoubrie P. Acceptability of oral iodinated contrast media: a head-to-head comparison of four media. Br J Radiol 2013; 86:20120636. [PMID: 23564884 DOI: 10.1259/bjr.20120636] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVE To assess the palatability of iodinated oral contrast media commonly used in abdominopelvic CT and CT colonography (CTC). METHODS 80 volunteers assessed the palatability of a 20-ml sample of a standard 30 mg ml(-1) dilution of Omnipaque® (iohexol; GE Healthcare, Cork, Ireland), Telebrix® (meglumine ioxithalamate; Guerbet, Aulnay-sous-Bois, France), Gastromiro® (iopamidol; Bracco, High Wycombe, UK) and Gastrografin® (sodium diatrizoate and meglumine diatrizoate; Bayer, Newbury, UK) in a computer-generated random order. RESULTS Gastrografin is rated significantly less palatable than the remaining media (p<0.005). Omnipaque and Telebrix are significantly more palatable than Gastromiro. No difference existed between Omnipaque and Telebrix. 39% of participants would refuse to consume the quantities of Gastrografin required for a CTC examination compared with Telebrix (7%) and Omnipaque (9%) (p<0.05). CONCLUSION Omnipaque and Telebrix are significantly more palatable than both Gastromiro and Gastrografin, with participants more willing to ingest them in larger quantities as well as being less expensive. ADVANCES IN KNOWLEDGE Omnipaque and Telebrix are significantly more palatable iodinated oral contrast media than both Gastromiro and Gastrografin, which has potential implications in compliance with both abdominopelvic CT and CTC.
Collapse
Affiliation(s)
- A Pollentine
- Department of Radiology, Southmead Hospital, Bristol, UK.
| | | | | |
Collapse
|
28
|
Boellaard TN, van der Paardt MP, Hollmann MW, Eberl S, Peringa J, Schouten LJ, Kavaliauskiene G, Runge JH, Tielbeek JAW, Stoker J. A multi-centre randomised double-blind placebo-controlled trial to evaluate the value of a single bolus intravenous alfentanil in CT colonography. BMC Gastroenterol 2013; 13:94. [PMID: 23706123 PMCID: PMC3671205 DOI: 10.1186/1471-230x-13-94] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2013] [Accepted: 05/21/2013] [Indexed: 01/23/2023] Open
Abstract
Background Pain is common during colonic insufflation required for CT colonography. We therefore evaluate whether a single intravenous alfentanil bolus has a clinically relevant analgesic effect compared with placebo in patients undergoing CT colonography. Methods A prospective multi-centre randomised double-blind placebo-controlled trial was performed in patients scheduled for elective CT colonography. Patients were randomised to receive either a bolus of 7.5 μg/kg alfentanil (n = 45) or placebo (n = 45). The primary outcome was the difference in maximum pain during colonic insufflation on an 11-point numeric rating scale. We defined a clinically relevant effect as a maximum pain reduction of at least 1.3 points. Secondary outcomes included total pain and burden of CT colonography (5-point scale), the most burdensome aspect and side effects. Our primary outcome was tested using a one-sided independent samples t-test. Results Maximum pain scores during insufflation were lower with alfentanil as compared with placebo, 5.3 versus 3.0 (P < 0.001). Total CT colonography pain and burden were also lower with alfentanil (2.0 vs. 1.6; P = 0.014 and 2.1 vs. 1.7; P = 0.007, respectively). With alfentanil fewer patients rated the insufflation as most burdensome aspect (56.1% vs. 18.6%; P = 0.001). Episodes with desaturations < 90% SpO2 were more common with alfentanil (8.1% vs. 44.4%; P < 0.001, but no clinically relevant desaturations occurred. Conclusions A low-dose intravenous alfentanil bolus provides a clinically relevant reduction of maximum pain during CT colonography and may improve the CT colonography acceptance, especially for patients with a low pain threshold. Trial registration Dutch Trial Register:
NTR2902
Collapse
|
29
|
van Ravesteijn VF, Boellaard TN, van der Paardt MP, Serlie IWO, de Haan MC, Stoker J, van Vliet LJ, Vos FM. Electronic cleansing for 24-h limited bowel preparation CT colonography using principal curvature flow. IEEE Trans Biomed Eng 2013; 60:3036-45. [PMID: 23674411 DOI: 10.1109/tbme.2013.2262046] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
CT colonography (CTC) is one of the recommended methods for colorectal cancer screening. The subject's preparation is one of the most burdensome aspects of CTC with a cathartic bowel preparation. Tagging of the bowel content with an oral contrast medium facilitates CTC with limited bowel preparation. Unfortunately, such preparations adversely affect the 3-D image quality. Thus far, data acquired after very limited bowel preparation were evaluated with a 2-D reading strategy only. Existing cleansing algorithms do not work sufficiently well to allow a primary 3-D reading strategy. We developed an electronic cleansing algorithm, aimed to realize optimal 3-D image quality for low-dose CTC with 24-h limited bowel preparation. The method employs a principal curvature flow algorithm to remove heterogeneities within poorly tagged fecal residue. In addition, a pattern recognition-based approach is used to prevent polyp-like protrusions on the colon surface from being removed by the method. Two experts independently evaluated 40 CTC cases by means of a primary 2-D approach without involvement of electronic cleansing as well as by a primary 3-D method after electronic cleansing. The data contained four variations of 24-h limited bowel preparation and was based on a low radiation dose scanning protocol. The sensitivity for lesions ≥ 6 mm was significantly higher for the primary 3-D reading strategy (84%) than for the primary 2-D reading strategy (68%) (p = 0.031). The reading time was increased from 5:39 min (2-D) to 7:09 min (3-D) (p = 0.005); the readers' confidence was reduced from 2.3 (2-D) to 2.1 (3-D) ( p = 0.013) on a three-point Likert scale. Polyp conspicuity for cleansed submerged lesions was similar to not submerged lesions (p = 0.06). To our knowledge, this study is the first to describe and clinically validate an electronic cleansing algorithm that facilitates low-dose CTC with 24-h limited bowel preparation.
Collapse
|
30
|
Sali L, Grazzini G, Ventura L, Falchini M, Borgheresi A, Castiglione G, Grimaldi M, Ianniciello N, Mallardi B, Zappa M, Mascalchi M. Computed tomographic colonography in subjects with positive faecal occult blood test refusing optical colonoscopy. Dig Liver Dis 2013; 45:285-9. [PMID: 23266193 DOI: 10.1016/j.dld.2012.11.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2012] [Revised: 10/29/2012] [Accepted: 11/12/2012] [Indexed: 12/11/2022]
Abstract
BACKGROUND Refusal of colonoscopy is a drawback of colorectal cancer screening programmes based on faecal occult blood test. Computed-tomographic-colonography is generally more accepted than colonoscopy. AIM To compare adherence to computed-tomographic-colonography and second-invitation colonoscopy in subjects with positive faecal test refusing colonoscopy. METHODS We performed a prospective study in 198 subjects with positive faecal test who refused first referral to colonoscopy in one endoscopy service of the Florence screening programme. Subjects were randomly invited to computed-tomographic-colonography (n = 100) or re-invited to colonoscopy (n = 98). Mail invitation was followed by a questionnaire administered by phone. Computed-tomographic-colonography findings were verified with colonoscopy. RESULTS 32 subjects could not be reached, 71 (35.9%) had undergone colonoscopy on their own; 4 were excluded for contraindications; 30/48 (62.5%) in the computed-tomographic-colonography arm and 11/43 (25.6%) in the colonoscopy arm accepted the proposed examinations (p < 0.001). Four advanced adenomas and 1 cancer were found in the 28 subjects who ultimately underwent computed-tomographic-colonography and 2 advanced adenomas and 2 cancers in the 9 subjects who ultimately underwent second-invitation colonoscopy. CONCLUSION Subjects with positive faecal occult blood test refusing colonoscopy show a higher adherence to computed-tomographic-colonography than to second invitation colonoscopy.
Collapse
Affiliation(s)
- Lapo Sali
- Radiodiagnostic Section, Department of Clinical Physiopathology, University of Florence, Viale G. Pieraccini 6, 50139 Florence, Italy.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Chen ZY, Shen HS, Luo MY, Duan CJ, Cai WL, Lu HB, Zhang GP, Liu Y, Liang JZ. Pilot study on efficacy of reduced cathartic bowel preparation with polyethylene glycol and bisacodyl. World J Gastroenterol 2013; 19:561-568. [PMID: 23382637 PMCID: PMC3558582 DOI: 10.3748/wjg.v19.i4.561] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2012] [Revised: 12/16/2012] [Accepted: 01/07/2013] [Indexed: 02/06/2023] Open
Abstract
AIM: To evaluate the efficacy of reduced cathartic bowel preparation with 2 L polyethylene glycol (PEG)-4000 electrolyte solution and 10 mg bisacodyl enteric-coated tablets for computed tomographic colonography (CTC).
METHODS: Sixty subjects who gave informed consent were randomly assigned to study group A, study group B or the control group. On the day prior to CTC, subjects in study group A were given 20 mL 40% wt/vol barium sulfate suspension before 3 mealtimes, 60 mL 60% diatrizoate meglumine diluted in 250 mL water after supper, and 10 mg bisacodyl enteric-coated tablets 1 h before oral administration of 2 L PEG-4000 electrolyte solution. Subjects in study group B were treated identically to those in study group A, with the exception of bisacodyl which was given 1 h after oral PEG-4000. Subjects in the control group were managed using the same strategy as the subjects in study group A, but without administration of bisacodyl. Residual stool and fluid scores, the attenuation value of residual fluid, and discomfort during bowel preparation in the three groups were analyzed statistically.
RESULTS: The mean scores for residual stool and fluid in study group A were lower than those in study group B, but the differences were not statistically significant. Subjects in study group A showed greater stool and fluid cleansing ability than the subjects in study group B. The mean scores for residual stool and fluid in study groups A and B were lower than those in the control group, and were significantly different. There was no significant difference in the mean attenuation value of residual fluid between study group A, study group B and the control group. The total discomfort index during bowel preparation was 46, 45 and 45 in the three groups, respectively, with no significant difference.
CONCLUSION: Administration of 10 mg bisacodyl enteric-coated tablets prior to or after oral administration of 2 L PEG-4000 electrolyte solution enhances stool and fluid cleansing ability, and has no impact on the attenuation value of residual fluid or the discomfort index. The former is an excellent alternative for CTC colorectum cleansing
Collapse
|
32
|
Lin OS, Kozarek RA, Gluck M, Jiranek GC, Koch J, Kowdley KV, Irani S, Nguyen M, Dominitz JA. Preference for colonoscopy versus computerized tomographic colonography: a systematic review and meta-analysis of observational studies. J Gen Intern Med 2012; 27:1349-60. [PMID: 22700393 PMCID: PMC3445696 DOI: 10.1007/s11606-012-2115-4] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2011] [Revised: 04/03/2012] [Accepted: 04/13/2012] [Indexed: 12/13/2022]
Abstract
In recent years, colorectal cancer (CRC) screening using computerized tomographic colonography (CTC) has attracted considerable attention. In order to better understand patient preferences for CTC versus colonoscopy, we performed a systematic review and meta-analysis of the available literature. Data sources included published studies, abstracts and book chapters, in any language, with publication dates from 1995 through February 2012, and with prospective or retrospective enrollment of diagnostic or screening patients who had undergone both procedures and explicit assessment of their preference for colonoscopy versus CTC. A predefined algorithm identified eligible studies using computer and hand searches performed by two independent investigators. We used a mixed effects model to pool preference differences (defined as the proportion of subjects who preferred CTC minus the proportion who preferred colonoscopy for each study). Twenty-three studies met inclusion criteria, totaling 5616 subjects. In 16 of these studies, patients preferred CTC over colonoscopy, while colonoscopy was preferred in three studies. Due to the high degree of heterogeneity, an overall pooled preference difference was not calculated. Stratified analysis revealed that studies published in radiology journals (preference difference 0.590 [95 % CI 0.485, 0.694]) seemed more likely than studies in gastroenterology (0.218 [-0.015-0.451]) or general medicine journals (-0.158 [-0.389-0.072]) to report preference for CTC (p<0.001). Studies by radiology authors showed a trend towards stronger preference for CTC compared with studies by gastroenterology authors. Symptomatic patients expressed no preference, but screening patients preferred CTC. There was no difference in preferences between studies using "masked" and "unmasked" preference ascertainment methods. Three studies featuring limited bowel preparations for CTC reported marked preference for CTC. There was no evidence of publication bias, while cumulative and exclusion analysis did not show any temporal trend or dominant study. Limitations included data heterogeneity and preference ascertainment limitations. In conclusion, most included studies reported preference for CTC. On stratified analysis, screening patients preferred CTC while diagnostic patients showed no preference. Studies published in radiology journals showed significantly stronger preference for CTC compared with studies in gastroenterology or general medicine journals.
Collapse
Affiliation(s)
- Otto S Lin
- C3-Gas, Gastroenterology Section, Virginia Mason Medical Center, 1100 Ninth Avenue, Seattle, WA 98101, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
33
|
The second ESGAR consensus statement on CT colonography. Eur Radiol 2012; 23:720-9. [PMID: 22983280 PMCID: PMC3563960 DOI: 10.1007/s00330-012-2632-x] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2011] [Revised: 03/18/2012] [Accepted: 04/01/2012] [Indexed: 12/14/2022]
Abstract
Objective To update quality standards for CT colonography based on consensus among opinion leaders within the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). Material and methods A multinational European panel of nine members of the ESGAR CT colonography Working Group (representing six EU countries) used a modified Delphi process to rate their level of agreement on a variety of statements pertaining to the acquisition, interpretation and implementation of CT colonography. Four Delphi rounds were conducted, each at 2 months interval. Results The panel elaborated 86 statements. In the final round the panelists achieved complete consensus in 71 of 86 statements (82 %). Categories including the highest proportion of statements with excellent Cronbach's internal reliability were colon distension, scan parameters, use of intravenous contrast agents, general guidelines on patient preparation, role of CAD and lesion measurement. Lower internal reliability was achieved for the use of a rectal tube, spasmolytics, decubitus positioning and number of CT data acquisitions, faecal tagging, 2D vs. 3D reading, and reporting. Conclusion The recommendations of the consensus should be useful for both the radiologist who is starting a CTC service and for those who have already implemented the technique but whose practice may need updating. Key Points • Computed tomographic colonography is the optimal radiological method of assessing the colon • This article reviews ESGAR quality standards for CT colonography • This article is aimed to provide CT-colonography guidelines for practising radiologists • The recommendations should help radiologists who are starting/updating their CTC services
Collapse
|
34
|
Zijta F, Nederveen A, Jensch S, Florie J, Bipat S, van der Paardt M, van Swijndregt AM, Stoker J. Feasibility of using automated insufflated carbon dioxide (CO2) for luminal distension in 3.0T MR colonography. Eur J Radiol 2012; 81:1128-33. [DOI: 10.1016/j.ejrad.2011.02.067] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2011] [Accepted: 02/28/2011] [Indexed: 11/25/2022]
|
35
|
Pollentine A, Mortimer A, McCoubrie P, Archer L. Evaluation of two minimal-preparation regimes for CT colonography: optimising image quality and patient acceptability. Br J Radiol 2012; 85:1085-92. [PMID: 22422379 DOI: 10.1259/bjr/22421731] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
OBJECTIVE To compare a 2 day bowel preparation regime of barium, iodine and a mild stimulant laxative with a 1 day iodine-only regime for CT colonography (CTC). METHODS 100 consecutive patients underwent CTC. The first 50 patients (Regime 1) ingested 1 bisacodyl tablet twice a day 3 days before CTC and 1 dose each of 50 ml of barium and 20 ml of iodinated contrast per day starting 2 days before CTC. The second 50 patients (Regime 2) ingested 3 doses of iodinated contrast over 24 h prior to CTC. Volumes of residual stool and fluid, and the effectiveness of stool and fluid tagging, were graded according to methods established by Taylor et al (Taylor S, Slaker A, Burling D, Tam E, Greenhalgh R, Gartner L, et al. CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging. Eur Radiol 2008; 18: 32-42). A 3 day low-residue diet was taken by both cohorts. Questionnaires rating the side-effects and burden of the bowel preparation were compared to a control cohort of patients undergoing barium enema. RESULTS The proportion of colons producing none/scattered stool (score 1) was 90.3% with Regime 1 and 65.0% with Regime 2 (p<0.005). Any residual stool was significantly better tagged with Regime 1 (score 5), with 91.7% of Regime 1 exhibiting optimum tagging vs 71.3% of Regime 2 (p<0.05). No significant differences in side-effects between the bowel preparation regimes for CTC were elicited. Bowel preparation for barium enema was tolerated significantly worse than both of the CTC bowel preparation regimes. CONCLUSION Regime 1, containing a 3 day preparation of a mild laxative, barium and iodine, produced a significantly better prepared colon, with no difference in patient acceptability.
Collapse
Affiliation(s)
- A Pollentine
- Department of Radiology, Southmead Hospital, Westbury-on-Trym, Bristol, UK.
| | | | | | | |
Collapse
|
36
|
Zueco Zueco C, Sobrido Sampedro C, Corroto JD, Rodriguez Fernández P, Fontanillo Fontanillo M. CT colonography without cathartic preparation: positive predictive value and patient experience in clinical practice. Eur Radiol 2012; 22:1195-204. [PMID: 22246146 DOI: 10.1007/s00330-011-2367-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2011] [Revised: 11/09/2011] [Accepted: 12/11/2011] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To determine the positive predictive value (PPV) for polyps ≥ 6 mm detected at CT colonography (CTC) performed without cathartic preparation, with low-dose iodine faecal tagging regimen and to evaluate patient experience. METHODS 1920 average-risk patients underwent CTC without cathartic preparation. Faecal tagging was performed by diatrizoate meglumine and diatrizoate sodium at a total dose of 60 ml (22.2 g of iodine).The standard interpretation method was primary 3D with 2D problem solving. We calculated per-patient and per-polyp PPV in relation to size and morphology. All colonic segments were evaluated for image quality (faecal tagging, amount of liquid and solid residual faeces and luminal distension). Patients completed a questionnaire before and after CTC to assess preparation and examination experience. RESULTS Per-polyp PPV for detected lesions of ≥ 6 mm, 6-9 mm, ≥ 10 mm and ≥ 30 mm were 94.3%, 93.1%, 94.7% and 98%, respectively. Per-polyp PPV, according to lesion morphology, was 94.6%, 97.3% and 85.1% for sessile, pedunculated and flat polyps, respectively. Per-patient PPV was 92.8%. Preparation without frank cathartics was reported to cause minimal discomfort by 78.9% of patients. CONCLUSION CTC without cathartic preparation and low-dose iodine faecal tagging may yield high PPVs for lesions ≥ 6 mm and is well accepted by patients. KEY POINTS • Computed tomographic colonography (CTC) without cathartic preparation is well accepted by patients • Cathartic-free faecal tagging CTC yields high positive predictive values • CTC without cathartic preparation could improve uptake of colorectal cancer screening.
Collapse
Affiliation(s)
- Carmen Zueco Zueco
- Complexo Hospitalario Universitario de Vigo - CHUVI, c/Pizarro 22, 36204 Vigo, Pontevedra, Spain.
| | | | | | | | | |
Collapse
|
37
|
Participation and yield of colonoscopy versus non-cathartic CT colonography in population-based screening for colorectal cancer: a randomised controlled trial. Lancet Oncol 2012; 13:55-64. [DOI: 10.1016/s1470-2045(11)70283-2] [Citation(s) in RCA: 266] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
38
|
Abstract
OBJECTIVES The aim of this study was to determine if the introduction of faecal tagging to CT colonography (CTC) made the examination easier to tolerate or reduced the number of false-positives. METHODS Our department changed bowel preparation for CT colonography from Picolax (Ferring Pharmaceuticals Ltd, London, UK) to Gastrografin (Bracco Diagnostics Inc, Princeton, NJ) only with a modified diet. Questionnaires were given to a subgroup of patients within these cohorts. The numbers of false-positives were compared between two cohorts before and after this change. false-positives were defined as lesions reported on CT that were not confirmed by subsequent endoscopic examination. Polyps were matched if they were in the same or adjacent segments, and were within 5 mm of the reported size. RESULTS 412 patients were identified from the Picolax cohort, and 116 from the Gastrografin cohort. 62 patients in each group completed questionnaires. Gastrografin produced less diarrhoea; 34% had five or more bowel motions in the previous day and night, compared with 77% for Picolax (p<0.001), although more patients found drinking it unpleasant compared with Picolax (85% reported drinking Picolax as "easy" vs 61% for Gastrografin; p=0.002). Picolax produced more non-diagnostic examinations, although this difference was not statistically significant. There was not a significant reduction in the numbers of false-positives (2 out of 112 for Gastrografin group, 14 out of 389 for the Picolax group; p=0.54). CONCLUSION Switching from Picolax to Gastrografin as a CTC preparation technique produced less diarrhoea, but did not reduce the number of false-positives.
Collapse
Affiliation(s)
- A Slater
- Department of Radiology, John Radcliffe Hospital, Oxford, UK.
| | | | | |
Collapse
|
39
|
Khan S, Ahmed J, Lim M, Owais A, McNaught C, Mainprize K, Babu S, Renwick I, MacFie J, Mitchell C. Colonoscopy in the octogenarian population: Diagnostic and survival outcomes from a large series of patients. Surgeon 2011; 9:195-9. [DOI: 10.1016/j.surge.2010.09.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2010] [Revised: 08/03/2010] [Accepted: 09/08/2010] [Indexed: 12/31/2022]
|
40
|
Pagés Llinás M, Darnell Martín A, Ayuso Colella J. CT colonography: What radiologists need to know. RADIOLOGIA 2011. [DOI: 10.1016/j.rxeng.2011.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
41
|
National CT colonography trial (ACRIN 6664): comparison of three full-laxative bowel preparations in more than 2500 average-risk patients. AJR Am J Roentgenol 2011; 196:1076-82. [PMID: 21512073 DOI: 10.2214/ajr.10.4334] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE The purpose of our study was to compare the effect of three different full-laxative bowel preparations on patient compliance, residual stool and fluid, reader confidence, and polyp detection at CT colonography (CTC). SUBJECTS AND METHODS A total of 2531 patients underwent CTC followed by colonoscopy for the American College of Radiology Imaging Network (ACRIN) National CTC Trial. Of this total, 2525 patients used one of three bowel preparations with bisacodyl tablets and stool and fluid tagging: 4 L of polyethylene glycol (PEG); 90 mL of phosphosoda; or 300 mL of magnesium citrate. Patients reported percent compliance with the bowel preparation and radiologists graded each CTC examination for the amount of residual fluid and stool on a scale from 1 (none) to 4 (nondiagnostic). Reader confidence for true-positive findings was reported on a 5-point scale: 1 (low) to 5 (high). Sensitivity and specificity for detecting polyps ≥ 6 mm and ≥ 1 cm compared with colonoscopy were calculated for each preparation. RESULTS The most commonly prescribed preparation was phosphosoda (n = 1403) followed by PEG (n = 1020) and magnesium citrate (n = 102). Phosphosoda had the highest patient compliance (p = 0.01), least residual stool (p < 0.001), and highest reader confidence versus PEG for examinations with polyps (p = 0.06). Magnesium citrate had significantly more residual fluid compared with PEG and phosphosoda (p = 0.006). The sensitivity and specificity for detecting colon polyps ≥ 6 mm and ≥ 1 cm did not differ significantly between preparations. CONCLUSION Polyp detection was comparable for all three preparations, although phosphosoda had significantly higher patient compliance and the least residual stool.
Collapse
|
42
|
Pagés Llinás M, Darnell Martín A, Ayuso Colella JR. [CT colonography: what radiologists need to know]. RADIOLOGIA 2011; 53:315-25. [PMID: 21696795 DOI: 10.1016/j.rx.2011.01.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2010] [Revised: 12/11/2010] [Accepted: 01/20/2011] [Indexed: 02/06/2023]
Abstract
In 2008, CT colonography was approved by the American Cancer Society as a technique for screening for colorectal cancer. This approval should be considered an important step in the recognition of the technique, which although still relatively new is already changing some diagnostic algorithms. This update about CT colonography reports the quality parameters necessary for a CT colonographic study to be diagnostic and reviews the technical innovations and colonic preparation for the study. We provide a brief review of the signs and close with a discussion of the current indications for and controversies about the technique.
Collapse
Affiliation(s)
- M Pagés Llinás
- Centro de Diagnóstico por la Imagen, Hospital Clínic de Barcelona, Barcelona, España.
| | | | | |
Collapse
|
43
|
CT colonography with limited bowel preparation for the detection of colorectal neoplasia in an FOBT positive screening population. ACTA ACUST UNITED AC 2011; 35:661-8. [PMID: 19888629 PMCID: PMC2980629 DOI: 10.1007/s00261-009-9586-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Purpose Aim was to evaluate the accuracy of computed tomography colonography (CTC) for detection of colorectal neoplasia in a Fecal Occult Blood Test (FOBT) positive screening population. Methods In three different institutions, consecutive FOBT positives underwent CTC after laxative free iodine tagging bowel preparation followed by colonoscopy with segmental unblinding. Each CTC was read by two experienced observers. For CTC and for colonoscopy the per-polyp sensitivity and per-patient sensitivity and specificity were calculated for detection of carcinomas, advanced adenomas, and adenomas. Results In total 22 of 302 included FOBT positive participants had a carcinoma (7%) and 137 had an adenoma or carcinoma ≥10 mm (45%). CTC sensitivity for carcinoma was 95% with one rectal carcinoma as false negative finding. CTC sensitivity for advanced adenomas was 92% (95% CI: 88–96) vs. 96% (95% CI: 93–99) for colonoscopy (P = 0.26). For adenomas and carcinomas ≥10 mm the CTC per-polyp sensitivity was 93% (95% CI: 89–97) vs. 97% (95% CI: 94–99) for colonoscopy (P = 0.17). The per-patient sensitivity for the detection of adenomas and carcinomas ≥10 mm was 95% (95% CI: 91–99) for CTC vs. 99% (95% CI: 98–100) for colonoscopy (P = 0.07), while the per-patient specificity was 90% (95% CI: 86–95) and 96% (95% CI: 94–99), respectively (P < 0.001). Conclusion CTC with limited bowel preparation performed in an FOBT positive screening population has high diagnostic accuracy for the detection of adenomas and carcinomas and a sensitivity similar to that of colonoscopy for relevant lesions.
Collapse
|
44
|
Decreased-Purgation CT Colonography: State of the Art. CURRENT COLORECTAL CANCER REPORTS 2011. [DOI: 10.1007/s11888-010-0085-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
45
|
Slater A, North M, Hart M, Ferrett C. Gas insufflation of minimal preparation CT of the colon reduces false-positives. Br J Radiol 2011; 85:346-50. [PMID: 21224295 DOI: 10.1259/bjr/20678489] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVES Minimal preparation CT of the colon (MPCT colon) is used for investigation of suspected colorectal cancer in frail and/or elderly patients who would be expected to tolerate laxative bowel preparation poorly. Although it has good sensitivity for colorectal cancer it has a poor specificity. We wished to investigate whether distension of the colon with carbon dioxide alone would reduce the number of false-positives, but without making the test arduous or excessively uncomfortable. METHODS 134 patients were recruited and underwent MPCT colon with gas insufflation and antispasmodics. Results were compared with a cohort of 134 patients undergoing standard protocol MPCT colon. The numbers of false-positives were compared, as was reader confidence. All trial patients were given a questionnaire documenting their experience. RESULTS The number of false-positives was 15% in the control group and 5% in the trial group; this difference was statistically significant, (p=0.01). Reader confidence was increased in the trial group. Patient tolerance was good, with 95% saying they would have the test again. CONCLUSION Use of gas insufflation and antispasmodics reduces the false-positives from 15% to 5% without adversely affecting patient tolerance.
Collapse
Affiliation(s)
- A Slater
- John Radcliffe Hospital, Headley Way, Headington, Oxford, UK.
| | | | | | | |
Collapse
|
46
|
Liedenbaum MH, Bipat S, Bossuyt PMM, Dwarkasing RS, de Haan MC, Jansen RJ, Kauffman D, van der Leij C, de Lijster MS, Lute CC, van der Paardt MP, Thomeer MG, Zijlstra IA, Stoker J. Evaluation of a standardized CT colonography training program for novice readers. Radiology 2010; 258:477-87. [PMID: 21177395 DOI: 10.1148/radiol.10100019] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
PURPOSE To determine how many computed tomographic (CT) colonography training studies have to be evaluated by novice readers to obtain an adequate level of competence in polyp detection. MATERIALS AND METHODS The study was approved by the Institutional Review Board. Informed consent was obtained from all participants. Six physicians (one radiologist, three radiology residents, two researchers) and three technicians completed a CT colonography training program. Two hundred CT colonographic examinations with colonoscopic verification were selected from a research database, with 100 CT colonographic examinations with at least one polyp 6 mm or larger. After a lecture session and short individual hands-on training, CT colonography training was done individually with immediate feedback of colonoscopy outcome. Per-polyp sensitivity was calculated for four sets of 50 CT colonographic examinations for lesions 6 mm or larger. By using logistic regression analyses, the number of CT colonographic examinations to reach 90% sensitivity for lesions 6 mm or larger was estimated. Reading times were registered. RESULTS The average per-polyp sensitivity for lesions 6 mm or larger was 76% (207 of 270) in the first set of 50 CT colonographic examinations, 77% (262 of 342) in the second (P = .96 vs first set), 80% (310 of 387) in the third (P = .67 vs first set), and 91% (261 of 288) in the fourth (P = .018). The estimated number of CT colonographic examinations for a sufficient sensitivity was 164. Six of nine readers reached this level of competence within 175 CT colonographic examinations. Reading times decreased significantly from the first to the second set of 50 CT colonographic examinations for six readers. CONCLUSION Novice CT colonography readers obtained sensitivity equal to that of experienced readers after practicing on average 164 CT colonographic studies.
Collapse
Affiliation(s)
- Marjolein H Liedenbaum
- Department of Radiology and Clinical Epidemiology and Biostatistics, Academic Medical Center Amsterdam, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Taylor SA, Bomanji JB, Manpanzure L, Robinson C, Groves AM, Dickson J, Papathanasiou ND, Greenhalgh R, Ell PJ, Halligan S. Nonlaxative PET/CT colonography: feasibility, acceptability, and pilot performance in patients at higher risk of colonic neoplasia. J Nucl Med 2010; 51:854-61. [PMID: 20484420 DOI: 10.2967/jnumed.109.072728] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
UNLABELLED CT colonography without bowel preparation is a safer and better-tolerated alternative to full laxation protocols, but comparative sensitivity and specificity are potentially reduced. Uptake of (18)F-FDG by colonic neoplasia is well described, and combining PET with nonlaxative CT colonography could improve accuracy. The purpose was to prospectively test the technical feasibility and acceptability of combined nonlaxative PET/CT colonography in patients at higher risk of colorectal neoplasia and to provide pilot data on diagnostic performance. METHODS Fifty-six patients (median age, 64 y; 30 women) at high risk of colonic neoplasia underwent nonlaxative PET/CT colonography with barium fecal tagging within 2 wk of scheduled colonoscopy. Colonic segmental distension was graded 1 (poor) to 3 (good). A radiologist, experienced in CT colonography, and nuclear medicine physician in consensus analyzed the datasets. The diagnostic performance for standalone CT colonography and combined PET/CT colonography was compared with the reference colonoscopy. Patient experience for 25 items (each scored from 1 to 7) pertaining to satisfaction, worry, and physical discomfort was canvassed after both PET/CT colonography and colonoscopy. RESULTS Distension was good in 298 of 334 segments (89%; 95% confidence interval [CI], 85%-92%). Patients experienced more physical discomfort during colonoscopy (median, 4; interquartile range [IQR], 2-7) than during PET/CT colonography (median, 5; IQR, 3-7; P = 0.03) and were more willing to undergo PET/CT colonography again (36/43 [84%; 95% CI, 73%-95%] vs. 31/43 [72%; 95% CI, 59%-86%]; P = 0.001). Twenty-one patients had 54 polyps according to colonoscopy (10 with at least 1 polyp >or=6 mm and 8 with at least 1 polyp >or=10 mm). Of 14 polyps 6 mm or greater, 12 (86%; 95% CI, 67%-100%) were (18)F-FDG-avid, including all those 10 mm or greater (mean standardized uptake value, 10.1). CT colonography sensitivity for polyps 6 mm or larger was 92.9% (95% CI, 79.4%-100%) and was not improved by the addition of PET. However, combined PET/CT colonography review improved per-patient positive predictive value for a polyp 10 mm or greater from 73% (95% CI, 39-92) to 100% (95% CI, 60-100). CONCLUSION In this feasibility study, simultaneous PET acquisition during nonlaxative CT colonography is technically feasible, is well tolerated, and potentially improves specificity.
Collapse
Affiliation(s)
- Stuart A Taylor
- Department of Specialist Radiology, University College London Hospital NHS Trust, London, United Kingdom.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Abstract
Computed tomographic colonography (CTC) is a promising emerging technology for imaging of the colon. This concise review discusses the currently available data on CTC technique, test characteristics, acceptance, safety, cost-effectiveness, follow-up strategy, and extracolonic findings. In summary, CTC technique is still evolving, and further research is needed to clarify the role of automated colonic insufflation, smooth-muscle relaxants, intravenous and oral contrast, software rendering, and patient positioning. Currently, full bowel preparation is still required to achieve optimal results. The sensitivity for detecting large polyps (> 1 cm) can be as high as 85%, with specificity of up to 97%. These test characteristics are almost comparable to those of conventional colonoscopy. Patient acceptance of CTC is generally higher than that for colonoscopy, especially in patients who have never undergone either procedure. CTC is generally safe, although uncommon instances of colonic perforation have been documented. In terms of cost-effectiveness, most decision analyses have concluded that CTC would only be cost-effective if it were considerably cheaper than conventional colonoscopy. The proper follow-up strategy for small polyps or incidental extracolonic findings discovered during CTC is still under debate. At present, the exact clinical role of virtual colonoscopy still awaits determination. Even though widespread CTC screening is not available today, in the future there may eventually be a role for this technology. Technological advances in this area will undoubtedly continue, with multi-detector row CT scanners allowing thinner collimation and higher resolution images. Stool-tagging techniques are likely to evolve and may eventually allow for low-preparation CTC. Perceptual and fatigue-related reading errors can potentially be minimized with the help of computer-aided detection software. Further research will define the exact role of this promising technology in our diagnostic armamentarium.
Collapse
|