1
|
Jia Z, Guo L, Yuan W, Dai J, Lu J, Li Z, Du X, Chen W, Liu X. Performance of dual-layer spectrum CT virtual monoenergetic images to assess early rectal adenocarcinoma T-stage: comparison with MR. Insights Imaging 2024; 15:11. [PMID: 38228903 DOI: 10.1186/s13244-023-01593-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 12/09/2023] [Indexed: 01/18/2024] Open
Abstract
OBJECTIVES To evaluate the image quality and utility of virtual monoenergetic images (VMI) of dual-layer spectrum computed tomography (DLSCT) in assessing preoperative T-stage for early rectal adenocarcinoma (ERA). METHODS This retrospective study included 67 ERA patients (mean age 62 ± 11.1 years) who underwent DLSCT and MR examination. VMI 40-200 keV and poly energetic image (PEI) were reconstructed. The image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and tumor contrast of different energy levels were calculated and compared, respectively. Two radiologists independently assess the image quality of the VMIs and PEI using 5-point scales. The diagnostic accuracies of DLSCT and HR-MRI for ERA T-staging were evaluated and compared. RESULTS The maximum noise was observed at VMI 40 keV, and noise at VMI 40-200 keV in the arterial and venous phases showed no significant difference (all p > 0.05). The highest SNR and CNR were obtained at VMI 40 keV, significantly greater than other energy levels and PEI (all p < 0.05). Tumor contrast was more evident than PEI at 40-100 keV in the arterial phase and at 40 keV in the venous phase (all p < 0.05). When compared with PEI, VMI 40 keV yielded the highest scores for overall image quality, tumor visibility, and tumor margin delineation, especially in the venous phase (p < 0.05). The overall diagnostic accuracy of DLSCT and HR-MRI for T-stage was 65.67 and 71.64% and showed no significant difference (p > 0.05). CONCLUSIONS VMI 40 keV improves image quality and accuracy in identifying lesions, providing better diagnostic information for ERA staging. CRITICAL RELEVANCE STATEMENT Low-keV VMI from DLSCT can improve tumor staging accuracy for early rectal carcinoma, helping guide surgical intervention decisions, and has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC. KEYPOINTS • Compared with PEI, low-keV VIM derived from DLSCT, particularly at the 40 keV, significantly enhanced the objective and subjective image quality of ERA. • Using VMI 40 keV helped increase lesion detectability, leading to improved diagnostic accuracy for ERA. • Low-keV VMI from DLSCT has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC.
Collapse
Affiliation(s)
- Ziqi Jia
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Lei Guo
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - WenJing Yuan
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - JianHao Dai
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - JianYe Lu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - ZhiQiang Li
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xiaohua Du
- Department of Pathology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Weicui Chen
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.
| | - Xian Liu
- Department of Radiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.
| |
Collapse
|
2
|
Zhou X, Cui M, Liu Y, Wu Y, Hu D, Zhai D, Qin M, Shen J, Ju S, Fan G, Cai W. Low Dose Iodinated Contrast Material and Radiation for Virtual Monochromatic Imaging in Craniocervical Dual-Layer Spectral Detector Computed Tomography Angiography: A Prospective and Randomized Study. Acad Radiol 2023:S1076-6332(23)00681-5. [PMID: 38135625 DOI: 10.1016/j.acra.2023.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 12/01/2023] [Accepted: 12/01/2023] [Indexed: 12/24/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate the feasibility of virtual monochromatic imaging (VMI) of dual-layer spectral detector computed tomography (SDCT) to reduce iodinated contrast material (CM) and radiation dose in craniocervical computed tomography angiography (CTA). MATERIALS AND METHODS A total of 280 consecutively selected patients performed craniocervical CTA with SDCT were prospectively selected and randomly divided into four groups (A, DoseRight index (DRI) 31, iopromide 370mgI/mL, volume 0.8 mL/kg; B, DRI 26, iopromide 370mgI/mL, volume 0.4 mL/kg; C, DRI 26, ioversol 320mgI/mL, volume 0.4 mL/kg; D, DRI 26, iohexol 300mgI/mL, volume 0.4 mL/kg). 50-70 kiloelectron volts (keV) VMIs in group B were reconstructed and compared to group A to select the optimal keV. Then, the optimal keV in groups B, C and D was reconstructed and compared. Objective image quality, including vascular attenuation, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), was evaluated. Subjective image quality was assessed using a 5-point Likert scale. In addition, the effective dose (ED), iodine load and iodine delivery rate (IDR) were compared between groups A and D. RESULTS 55 keV VMI was the optimal VMI in group B. The objective and subjective image quality of 55 keV VMI in group B were equal to or better than those of the CI in group A. The SNR, CNR and subjective image quality in group D were similar to those in group B (P > 0.05). The ED, iodine load and IDR of group D were reduced by 44%, 59% and 19%, respectively, when compared to those of group A. CONCLUSION Low dose iodinated CM and radiation for 55 keV VMI in craniocervical CTA using SDCT could still provide equivalent or better image quality than the conventional scanning protocol.
Collapse
Affiliation(s)
- Xiuzhi Zhou
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Manman Cui
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Yan Liu
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Yuanyuan Wu
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Dongliang Hu
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Duchang Zhai
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Mingyu Qin
- Suzhou Medical College of Soochow University, Suzhou, 215026, Jiangsu, China (M.Q.)
| | - Junkang Shen
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Shenghong Ju
- Department of Radiology, Zhongda Hospital, Medical School of Southeast University, Nanjing, 210009, Jiangsu, China (S.J.)
| | - Guohua Fan
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.)
| | - Wu Cai
- Department of Radiology, The Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Gusu, Suzhou, 215004, Jiangsu, China (X.Z., M.C., Y.L., Y.W., D.H., D.Z., J.S., G.F., W.C.).
| |
Collapse
|
3
|
Chang Y, Xing H, Shang Y, Liu Y, Yu L, Dai H. Preoperative predicting invasiveness of lung adenocarcinoma manifesting as ground-glass nodules based on multimodal images of dual-layer spectral detector CT radiomics models. J Cancer Res Clin Oncol 2023; 149:15425-15438. [PMID: 37642725 DOI: 10.1007/s00432-023-05311-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 08/16/2023] [Indexed: 08/31/2023]
Abstract
OBJECTIVE To construct and validate conventional and radiomics models based on dual-layer spectral CT radiomics for preoperative prediction of lung ground glass nodules (GGNs) invasiveness. MATERIALS AND METHODS A retrospective study was conducted on 176 GGNs patients who underwent chest non-contrast enhancement scan on dual-layer spectral detector CT at our hospital within 2 weeks before surgery. Patients were randomized into the training cohort and testing cohort. Clinical features, imaging features and spectral quantitative parameters were collected to establish a conventional model. Radiomics models were established by extracting 1781 radiomics features form regions of interest of each spectral image [120 kVp poly energetic images (PI), 60 keV images and electron density maps], respectively. After selecting the optimal radiomic features and integrating multiple machine learning models, the conventional model, PI model, 60 keV model, electron density (ED) model and combined model based on multimodal spectral images were finally established. The performance of these models was assessed through the evaluation of discrimination, calibration, and clinical application. RESULTS In the conventional model, age, vacuole sign, 60 keV and ED were independent risk factors of invasiveness. The combined model using logistic regression-least absolute shrinkage and selection operator classifiers was the optimal model with a higher area under the curve of the training (0.961, 95% confidence interval, CI: 0.932-0.991) and testing set (0.944, 0.890-0.999). CONCLUSION The combined models are helpful to predict the invasiveness of GGNs before surgery and guide the individualized treatment of patients.
Collapse
Affiliation(s)
- Yue Chang
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, 215006, Jiangsu Province, People's Republic of China
| | - Hanqi Xing
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, 215006, Jiangsu Province, People's Republic of China
| | - Yi Shang
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, 215006, Jiangsu Province, People's Republic of China
| | - Yuanqing Liu
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, 215006, Jiangsu Province, People's Republic of China
| | - Lefan Yu
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, 215006, Jiangsu Province, People's Republic of China
| | - Hui Dai
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, 215006, Jiangsu Province, People's Republic of China.
- Institute of Medical Imaging, Soochow University, Suzhou, 215006, Jiangsu Province, People's Republic of China.
- Suzhou Key Laboratory of Intelligent Medicine and Equipment, Suzhou, 215123, Jiangsu Province, People's Republic of China.
| |
Collapse
|
4
|
Zhu Y, Wang P, Wang B, Jiang Z, Li Y, Jiang J, Zhong Y, Xue L, Jiang L. Dual-layer spectral-detector CT for predicting microsatellite instability status and prognosis in locally advanced gastric cancer. Insights Imaging 2023; 14:151. [PMID: 37726599 PMCID: PMC10509117 DOI: 10.1186/s13244-023-01490-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 07/31/2023] [Indexed: 09/21/2023] Open
Abstract
OBJECTIVE To construct and validate a prediction model based on dual-layer detector spectral CT (DLCT) and clinico-radiologic features to predict the microsatellite instability (MSI) status of gastric cancer (GC) and to explore the relationship between the prediction results and patient prognosis. METHODS A total of 264 GC patients who underwent preoperative DLCT examination were randomly allocated into the training set (n = 187) and validation set (n = 80). Clinico-radiologic features and DLCT parameters were used to build the clinical and DLCT model through multivariate logistic regression analysis. A combined DLCT parameter (CDLCT) was constructed to predict MSI. A combined prediction model was constructed using multivariate logistic regression analysis by integrating the significant clinico-radiologic features and CDLCT. The Kaplan-Meier survival analysis was used to explore the prognostic significant of the prediction results of the combined model. RESULTS In this study, there were 70 (26.52%) MSI-high (MSI-H) GC patients. Tumor location and CT_N staging were independent risk factors for MSI-H. In the validation set, the area under the curve (AUC) of the clinical model and DLCT model for predicting MSI status was 0.721 and 0.837, respectively. The combined model achieved a high prediction efficacy in the validation set, with AUC, sensitivity, and specificity of 0.879, 78.95%, and 75.4%, respectively. Survival analysis demonstrated that the combined model could stratify GC patients according to recurrence-free survival (p = 0.010). CONCLUSION The combined model provides an efficient tool for predicting the MSI status of GC noninvasively and tumor recurrence risk stratification after surgery. CRITICAL RELEVANCE STATEMENT MSI is an important molecular subtype in gastric cancer (GC). But MSI can only be evaluated using biopsy or postoperative tumor tissues. Our study developed a combined model based on DLCT which could effectively predict MSI preoperatively. Our result also showed that the combined model could stratify patients according to recurrence-free survival. It may be valuable for clinicians in choosing appropriate treatment strategies to avoid tumor recurrence and predicting clinical prognosis in GC. KEY POINTS • Tumor location and CT_N staging were independent predictors for MSI-H in GC. • Quantitative DLCT parameters showed potential in predicting MSI status in GC. • The combined model integrating clinico-radiologic features and CDLCT could improve the predictive performance. • The prediction results could stratify the risk of tumor recurrence after surgery.
Collapse
Affiliation(s)
- Yongjian Zhu
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Peng Wang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Bingzhi Wang
- Department of Pathology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Zhichao Jiang
- Department of Medical Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Ying Li
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Jun Jiang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Yuxin Zhong
- Department of Pancreatic and Gastric Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Liyan Xue
- Department of Pathology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Liming Jiang
- Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| |
Collapse
|
5
|
Xu H, Zhu N, Yue Y, Guo Y, Wen Q, Gao L, Hou Y, Shang J. Spectral CT-based radiomics signature for distinguishing malignant pulmonary nodules from benign. BMC Cancer 2023; 23:91. [PMID: 36703132 PMCID: PMC9878920 DOI: 10.1186/s12885-023-10572-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Accepted: 01/20/2023] [Indexed: 01/27/2023] Open
Abstract
OBJECTIVES To evaluate the discriminatory capability of spectral CT-based radiomics to distinguish benign from malignant solitary pulmonary solid nodules (SPSNs). MATERIALS AND METHODS A retrospective study was performed including 242 patients with SPSNs who underwent contrast-enhanced dual-layer Spectral Detector CT (SDCT) examination within one month before surgery in our hospital, which were randomly divided into training and testing datasets with a ratio of 7:3. Regions of interest (ROIs) based on 40-65 keV images of arterial phase (AP), venous phases (VP), and 120kVp of SDCT were delineated, and radiomics features were extracted. Then the optimal radiomics-based score in identifying SPSNs was calculated and selected for building radiomics-based model. The conventional model was developed based on significant clinical characteristics and spectral quantitative parameters, subsequently, the integrated model combining radiomics-based model and conventional model was established. The performance of three models was evaluated with discrimination, calibration, and clinical application. RESULTS The 65 keV radiomics-based scores of AP and VP had the optimal performance in distinguishing benign from malignant SPSNs (AUC65keV-AP = 0.92, AUC65keV-VP = 0.88). The diagnostic efficiency of radiomics-based model (AUC = 0.96) based on 65 keV images of AP and VP outperformed conventional model (AUC = 0.86) in the identification of SPSNs, and that of integrated model (AUC = 0.97) was slightly further improved. Evaluation of three models showed the potential for generalizability. CONCLUSIONS Among the 40-65 keV radiomics-based scores based on SDCT, 65 keV radiomics-based score had the optimal performance in distinguishing benign from malignant SPSNs. The integrated model combining radiomics-based model based on 65 keV images of AP and VP with Zeff-AP was significantly superior to conventional model in the discrimination of SPSNs.
Collapse
Affiliation(s)
- Hang Xu
- grid.412467.20000 0004 1806 3501Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| | - Na Zhu
- grid.416466.70000 0004 1757 959XDepartment of Radiation Oncology, Nanfang Hospital of Southern Medical University, Guangzhou, 510000 China
| | - Yong Yue
- grid.412467.20000 0004 1806 3501Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| | - Yan Guo
- GE Healthcare, Shenyang, 110004 China
| | - Qingyun Wen
- grid.459518.40000 0004 1758 3257Department of Radiology, Jining First People’s Hospital, Jining, 272000 China
| | - Lu Gao
- Department of Radiology, Liaoning Province Cancer Hospital, Shenyang, 110801 China
| | - Yang Hou
- grid.412467.20000 0004 1806 3501Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| | - Jin Shang
- grid.412467.20000 0004 1806 3501Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| |
Collapse
|
6
|
Taguchi N, Oda S, Imuta M, Yamamura S, Yokota Y, Nakaura T, Nagayama Y, Kidoh M, Utsunomiya D, Funama Y, Baba H, Yamashita Y. Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing. Eur J Radiol 2018; 108:7-12. [PMID: 30396674 DOI: 10.1016/j.ejrad.2018.09.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 07/31/2018] [Accepted: 09/10/2018] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To assess the utility of virtual monochromatic imaging (VMI) using a dual-layer spectral detector CT for electronic cleansing in fecal-tagging CT colonography (CTC). METHODS This study included 35 patients who underwent fecal-tagging CTC with a dual-layer detector spectral CT scanner. Conventional images at 120 kVp and VMI at 40, 50, and 60 keV were reconstructed. Quantitative image quality parameters, i.e., tagging density and image noise, were compared and the visual image quality was scored on a four-point scale. We recorded the number of the colon segments with appropriate tagging density (≥300 HU) for each patient and used these data to compare the reconstructions. In addition, electronic cleansing performance was semi-quantitatively assessed using a four-point scale. RESULTS The mean tagging density on VMI was significantly higher than that on conventional 120 kVp images. The number of colon segments with appropriate tagging density on VMI were significantly higher than that on conventional 120 kVp images. There was no significant difference among the reconstructed images with respect to image noise. Scores for subjective image quality and electronic cleansing performance on VMI were significantly higher than those on conventional 120 kVp images. CONCLUSION With dual-layer spectral detector CT, VMI can yield significantly better fecal-tagged CTC image quality and improve electronic cleansing performance.
Collapse
Affiliation(s)
- Narumi Taguchi
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Seitaro Oda
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan.
| | - Masanori Imuta
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Sadahiro Yamamura
- Department of Radiology, Kumamoto General Hospital, 10-10 Toricho, Yatsushiro, Kumamoto, 866-8660, Japan
| | - Yasuhiro Yokota
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yasunori Nagayama
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Masafumi Kidoh
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Daisuke Utsunomiya
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Hideo Baba
- Department of Gastroenterological Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan
| |
Collapse
|
7
|
Doerner J, Luetkens JA, Iuga AI, Byrtus J, Haneder S, Maintz D, Hickethier T. Poly-energetic and virtual mono-energetic images from a novel dual-layer spectral detector CT: optimization of window settings is crucial to improve subjective image quality in abdominal CT angiographies. Abdom Radiol (NY) 2018; 43:742-50. [PMID: 28677003 DOI: 10.1007/s00261-017-1241-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
PURPOSE We aimed to determine optimal window settings for poly-energetic (PolyE) and virtual mono-energetic images (MonoE) derived from abdominal angiographic studies on a novel dual-layer spectral detector CT (SDCT) system. METHODS From 50 patients, SDCT datasets PolyE and MonoE at 70 and 40 keV levels were reconstructed and best individual window width and level (BI-W/L) manually assessed. Through regression analysis, the so-called optimized individual (OI-W/L) values were obtained. Subjective image quality parameters and vessel diameters were measured to determine influences of different W/L settings. RESULTS Image noise was lower and attenuation and contrast-to-noise ratio were higher in MonoE compared to PolyE (all p ≤ 0.002). Mean BI-W/L values for PolyE, 70, and 40 keV were 637/284, 647/291, and 1568/691, respectively. Mean OI-W/L values were 631/276, 628/286, and 1516/667, respectively. Compared to standard settings, all adjusted W/L settings varied significantly and yielded higher subjective scoring. No between-group differences were found between manually adjusted and mathematically calculated W/L settings. CONCLUSION PolyE and MonoE from abdominal angiographic SDCT studies require appropriate W/L settings especially at low energy reconstruction levels. Individual adjustment reaches the best image quality but is time consuming. From our data, predefined W/L settings of 640/280 (PolyE/MonoE 70 keV) and 1570/690 (MonoE 40 keV) as a non-individualized starting point for abdominal angiographic studies from the novel SDCT system are suggested.
Collapse
|
8
|
Oda S, Nakaura T, Utsunomiya D, Funama Y, Taguchi N, Imuta M, Nagayama Y, Yamashita Y. Clinical potential of retrospective on-demand spectral analysis using dual-layer spectral detector-computed tomography in ischemia complicating small-bowel obstruction. Emerg Radiol 2017; 24:431-4. [PMID: 28462483 DOI: 10.1007/s10140-017-1511-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Accepted: 04/21/2017] [Indexed: 01/17/2023]
Abstract
We describe a case of ischemia complicating acute small-bowel obstruction in which retrospective on-demand spectral analysis using dual-layer spectral detector computed tomography (CT) provided a higher degree of confidence pertaining to the diagnosis. Dual-layer spectral detector CT enables retrospective on-demand spectral analysis, including virtual monochromatic imaging, iodine mapping, and determining the effective atomic number Z, without the need of a pre-scan setting requiring a special protocol, particularly facilitating emergency situations. Retrospective on-demand spectral analysis could improve the accuracy and diagnostic confidence in cases with ischemia complicating small-bowel obstruction.
Collapse
|
9
|
van Hamersvelt RW, Schilham AMR, Engelke K, den Harder AM, de Keizer B, Verhaar HJ, Leiner T, de Jong PA, Willemink MJ. Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study. Eur Radiol 2017; 27:4351-4359. [PMID: 28374079 PMCID: PMC5579207 DOI: 10.1007/s00330-017-4801-4] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Accepted: 03/13/2017] [Indexed: 12/20/2022]
Abstract
OBJECTIVES To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols. METHODS Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm3 calcium hydroxyapatite (HA) were scanned using a 64-slice SDCT scanner at various acquisition protocols (120 and 140 kVp, and 50, 100 and 200 mAs). Regions of interest (ROIs) were placed in each insert and mean attenuation profiles at monochromatic energy levels (90-200 keV) were constructed. These profiles were fitted to attenuation profiles of pure HA and water to calculate HA concentrations. For comparison, one phantom was scanned using dual energy X-ray absorptiometry (DXA). RESULTS At both 120 and 140 kVp, excellent correlations (R = 0.97, P < 0.001) were found between true and measured HA concentrations. Mean error for all measurements at 120 kVp was -5.6 ± 5.7 mg/cm3 (-3.6 ± 3.2%) and at 140 kVp -2.4 ± 3.7 mg/cm3 (-0.8 ± 2.8%). Mean measurement errors were smaller than 6% for all acquisition protocols. Strong linear correlations (R2 ≥ 0.970, P < 0.001) with DXA were found. CONCLUSIONS SDCT allows for accurate BMD quantification and potentially opens up the possibility for osteoporosis evaluation and opportunistic screening in patients undergoing SDCT for other clinical indications. However, patient studies are needed to extend and translate our findings. KEY POINTS • Dual-layer spectral detector CT allows for accurate bone mineral density quantification. • BMD measurements on SDCT are strongly linearly correlated to DXA. • SDCT, acquired for several indications, may allow for evaluation of osteoporosis. • This potentially opens up the possibility for opportunistic osteoporosis screening.
Collapse
Affiliation(s)
- Robbert W van Hamersvelt
- Department of Radiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
| | - Arnold M R Schilham
- Department of Radiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| | - Klaus Engelke
- Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen, Germany
| | - Annemarie M den Harder
- Department of Radiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| | - Bart de Keizer
- Department of Nuclear Medicine, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Harald J Verhaar
- Department of Geriatric Medicine, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Tim Leiner
- Department of Radiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| | - Pim A de Jong
- Department of Radiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| | - Martin J Willemink
- Department of Radiology, University Medical Centre Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| |
Collapse
|
10
|
van Hamersvelt RW, Willemink MJ, de Jong PA, Milles J, Vlassenbroek A, Schilham AMR, Leiner T. Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study. Eur Radiol 2017; 27:3677-3686. [PMID: 28124106 PMCID: PMC5544796 DOI: 10.1007/s00330-017-4737-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Revised: 12/12/2016] [Accepted: 01/03/2017] [Indexed: 01/24/2023]
Abstract
Objectives The aim of this study was to evaluate the feasibility and accuracy of dual-layer spectral detector CT (SDCT) for the quantification of clinically encountered gadolinium concentrations. Methods The cardiac chamber of an anthropomorphic thoracic phantom was equipped with 14 tubular inserts containing different gadolinium concentrations, ranging from 0 to 26.3 mg/mL (0.0, 0.1, 0.2, 0.4, 0.5, 1.0, 2.0, 3.0, 4.0, 5.1, 10.6, 15.7, 20.7 and 26.3 mg/mL). Images were acquired using a novel 64-detector row SDCT system at 120 and 140 kVp. Acquisitions were repeated five times to assess reproducibility. Regions of interest (ROIs) were drawn on three slices per insert. A spectral plot was extracted for every ROI and mean attenuation profiles were fitted to known attenuation profiles of water and pure gadolinium using in-house-developed software to calculate gadolinium concentrations. Results At both 120 and 140 kVp, excellent correlations between scan repetitions and true and measured gadolinium concentrations were found (R > 0.99, P < 0.001; ICCs > 0.99, CI 0.99–1.00). Relative mean measurement errors stayed below 10% down to 2.0 mg/mL true gadolinium concentration at 120 kVp and below 5% down to 1.0 mg/mL true gadolinium concentration at 140 kVp. Conclusion SDCT allows for accurate quantification of gadolinium at both 120 and 140 kVp. Lowest measurement errors were found for 140 kVp acquisitions. Key Points • Gadolinium quantification may be useful in patients with contraindication to iodine. • Dual-layer spectral detector CT allows for overall accurate quantification of gadolinium. • Interscan variability of gadolinium quantification using SDCT material decomposition is excellent.
Collapse
Affiliation(s)
- Robbert W van Hamersvelt
- Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands.
| | - Martin J Willemink
- Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| | - Pim A de Jong
- Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| | - Julien Milles
- CT Clinical Science, Philips HealthCare, Best, The Netherlands
| | | | - Arnold M R Schilham
- Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| | - Tim Leiner
- Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, 3508 GA, Utrecht, The Netherlands
| |
Collapse
|