1
|
Kise Y, Møystad A, Kuwada C, Ariji E, Bjørnland T. Does ultrasound elastography have a role as a diagnostic method for Sjögren's syndrome in the salivary glands? A systematic review. Oral Radiol 2024; 40:329-341. [PMID: 38308723 DOI: 10.1007/s11282-024-00740-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 01/04/2024] [Indexed: 02/05/2024]
Abstract
OBJECTIVE This systematic review was performed to examine the usefulness of salivary gland ultrasound elastography (USE) as a diagnostic tool for Sjögren's syndrome (SjS). METHODS Electronic databases (MEDLINE, EMBASE, the Cochrane Library, and Web of Science: Science Citation Index) were searched to identify studies using USE to diagnose SjS from database inception to 15 July 2022. The primary outcome was improved diagnostic accuracy for SjS with the use of USE. Risk of bias and applicability concerns were assessed using the GRADE system, which is continuously developed by the GRADE Working Group. RESULTS Among 4550 screened studies, 24 full-text articles describing the applications of USE to diagnose SjS were reviewed. The overall risk of bias was determined to be low for 17 of the 24 articles, medium for 5, and high for 2. Articles comparing patients with SjS and healthy subjects reported high diagnostic accuracy of USE, with most results showed statistically significant differences (parotid glands: 15 of the 16 articles, submandibular glands: 11 of the 14 articles). CONCLUSIONS This systematic review suggests that the assessment of salivary glands using USE is a useful diagnostic tool for SjS.
Collapse
Affiliation(s)
- Yoshitaka Kise
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Aichi Gakuin University, 2-11 Suemori-dori, Chikusa-Ku, Nagoya, 464-8651, Japan.
| | - Anne Møystad
- Department of Maxillofacial Radiology, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Oslo, Norway
| | - Chiaki Kuwada
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Aichi Gakuin University, 2-11 Suemori-dori, Chikusa-Ku, Nagoya, 464-8651, Japan
| | - Eiichiro Ariji
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Aichi Gakuin University, 2-11 Suemori-dori, Chikusa-Ku, Nagoya, 464-8651, Japan
| | - Tore Bjørnland
- Department of Oral Surgery and Oral Medicine, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Oslo, Norway
| |
Collapse
|
2
|
Dai X, Sui X, Chen S, Zhao B, Liu Z, Wang X. The diagnostic performance of salivary gland ultrasound elastography in Sjögren's syndrome and sicca symptoms: a systematic review and meta-analysis. Eur Radiol 2024; 34:1545-1555. [PMID: 37658892 DOI: 10.1007/s00330-023-10166-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 06/29/2023] [Accepted: 07/19/2023] [Indexed: 09/05/2023]
Abstract
OBJECTIVE To systematically evaluate the diagnostic performance of ultrasound elastography (USE) in distinguishing primary Sjögren's syndrome (pSS) from healthy/disease controls. METHODS We searched the PubMed, Embase, Web of Science, and Cochrane Library databases for published literature on USE for diagnosing pSS. Bivariate random effects models were used to calculate the pooled sensitivity and specificity of USE. To determine the factors influencing heterogeneity, meta-regression and subgroup analyses were performed to assess country, diagnostic criteria, imaging mechanisms, shear wave elastography techniques, measurement location, control group category, and patient age. Publication bias was assessed using the asymmetry of the Deeks funnel plot. RESULTS Fifteen articles covering 816 patients and 735 control participants were included. USE showed a pooled sensitivity of 0.80 (95% CI: 0.71-0.87) and specificity of 0.87 (95% CI: 0.78-0.92). Meta-regression and subgroup analyses revealed that shear wave elastography techniques, measurement location, and patient age were significant factors that affected study heterogeneity (p < 0.05). Elastography performs better in diagnosing patients aged ≤ 51 years compared to patients aged > 51 years. There was no significant publication bias. CONCLUSION USE demonstrates high accuracy in differentiating between pSS and healthy/disease control groups. CLINICAL RELEVANCE STATEMENT Ultrasound elastography, as a non-invasive and cost-effective technique, can be used to distinguish primary Sjögren's syndrome from disease/healthy control groups by measuring the stiffness of salivary glands. KEY POINTS • Ultrasound elastography is an acceptable technique for the diagnosis of primary Sjögren's syndrome. • The pooled sensitivity and specificity of ultrasound elastography for diagnosing primary Sjögren's syndrome were 0.80 and 0.87, respectively. • In patients aged ≤ 51 years with primary Sjögren's syndrome, ultrasound elastography showed good diagnostic performance.
Collapse
Affiliation(s)
- Xinpeng Dai
- Department of Ultrasound, Hebei Medical University Third Affiliated Hospital, No.139 Ziqiang Road, Qiaoxi District, Shijiazhuang, Hebei Province, China
| | - Xin Sui
- Department of Ultrasound, Hebei Medical University Third Affiliated Hospital, No.139 Ziqiang Road, Qiaoxi District, Shijiazhuang, Hebei Province, China.
| | - Simei Chen
- Department of Ultrasound, Hebei Medical University Third Affiliated Hospital, No.139 Ziqiang Road, Qiaoxi District, Shijiazhuang, Hebei Province, China
| | - Bingxin Zhao
- Department of Ultrasound, Hebei Medical University Third Affiliated Hospital, No.139 Ziqiang Road, Qiaoxi District, Shijiazhuang, Hebei Province, China
| | - Zongjie Liu
- Department of Ultrasound, Hebei Medical University Third Affiliated Hospital, No.139 Ziqiang Road, Qiaoxi District, Shijiazhuang, Hebei Province, China
| | - Xiaoyan Wang
- Department of Ultrasound, Hebei General Hospital, NO.348 Heping West Road, Xinhua District, Shijiazhuang, Hebei Province, China
| |
Collapse
|
3
|
Hofauer B, Roth A, Heiser C, Schukraft J, Johnson F, Zhu Z, Knopf A. Point Shear Wave Elastography in Diagnosis and Follow-Up of Salivary Gland Affection after Head and Neck Cancer Treatment. J Clin Med 2022; 11:jcm11216285. [PMID: 36362513 PMCID: PMC9654639 DOI: 10.3390/jcm11216285] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 10/20/2022] [Accepted: 10/23/2022] [Indexed: 11/16/2022] Open
Abstract
Therapies of head and neck squamous cell carcinoma (HNSCC), particularly irradiation and chemotherapy (C/RT), can affect salivary glands to some extent. Recent studies suggest that point shear wave elastography (pSWE) is well suited for the diagnosis and rating of homogenous damage to parenchymatous organs. The purpose of this study was to assess the value of this sonographic modality as a tool for the evaluation both of salivary gland affection after HNSCC therapy and the effect of a salivary replacement therapy based on liposomes. A total of 69 HNSCC patients were included in this study. All patients had finished cancer treatment and attended regular follow-up. pSWE values of ipsi- and contralateral parotid (PG) and submandibular glands (SMG) were obtained in a standardized manner and compared to those of a healthy control (HC) group. After a two months treatment with a liposomal saliva replacement therapy pSWE quantification was performed again. Ipsi- and contralateral salivary glands suffer under standard HNSCC tumor therapy. Here, the ipsilateral parotid gland (PG) is primarily affected. Therefore, a sequence of manifestation (surgery < surgery plus adjuvant C/RT < primary C/RT) is comprehensible, evaluated by pSWE measurements. The examination of all glands and statistical analysis of the values compared to controls resulted in an pSWE cutoff value for affected glandular tissue of >2 m/s. Using a liposomal saliva replacement therapy, pSWE values of the ipsilateral PG can be improved, although the level of HC could not be restored.
Collapse
Affiliation(s)
- Benedikt Hofauer
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany
- Correspondence:
| | - Andreas Roth
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany
| | - Clemens Heiser
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany
| | - Johannes Schukraft
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany
| | - Felix Johnson
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany
| | - Zhaojun Zhu
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany
| | - Andreas Knopf
- Department of Otorhinolaryngology, University Medical Center Freiburg, 79106 Freiburg, Germany
| |
Collapse
|
4
|
Lorenzon M, Spina E, Tulipano Di Franco F, Giovannini I, De Vita S, Zabotti A. Salivary Gland Ultrasound in Primary Sjögren’s Syndrome: Current and Future Perspectives. Open Access Rheumatol 2022; 14:147-160. [PMID: 36072437 PMCID: PMC9444027 DOI: 10.2147/oarrr.s284763] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 08/24/2022] [Indexed: 12/12/2022] Open
Affiliation(s)
- Michele Lorenzon
- Institute of Radiology, Department of Medicine, University of Udine, Udine, Italy
- Correspondence: Michele Lorenzon, Institute of Radiology, Department of Medicine, University of Udine, Udine, Italy, Tel +39 0432 559232, Email
| | - Erica Spina
- Institute of Radiology, Department of Medicine, University of Udine, Udine, Italy
| | | | - Ivan Giovannini
- Rheumatology Clinic, Department of Medical and Biological Sciences, Azienda Sanitaria Universitaria Friuli Centrale c/o University of Udine, Udine, Italy
| | - Salvatore De Vita
- Rheumatology Clinic, Department of Medical and Biological Sciences, Azienda Sanitaria Universitaria Friuli Centrale c/o University of Udine, Udine, Italy
| | - Alen Zabotti
- Rheumatology Clinic, Department of Medical and Biological Sciences, Azienda Sanitaria Universitaria Friuli Centrale c/o University of Udine, Udine, Italy
| |
Collapse
|
5
|
Shear wave elastography as a potential additional diagnostic tool in primary Sjögren's syndrome: an observational study. Rheumatol Int 2022; 42:1579-1587. [PMID: 35507104 DOI: 10.1007/s00296-022-05120-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 03/17/2022] [Indexed: 10/18/2022]
Abstract
The primary aim of this study was to verify if shear wave elastography can be used to evaluate salivary gland involvement in primary Sjögren's syndrome (pSS). The secondary objective was to establish an accurate cut-off value for parotid and submandibular salivary gland stiffness and to verify whether there are any distinctions among pSS patients with or without subjective mouth dryness. This prospective study included 45 patients with pSS (2016 ACR/EULAR classification criteria) and 108 healthy controls. All subjects underwent bilateral shear wave elastography of the parotid and submandibular salivary glands. Clinical data of pSS patients were collected and compared to elastography results. Patients with pSS had significantly higher shear wave elastography values for the parotid and submandibular salivary glands than the controls. There were no statistical differences in SWE values between patients with or without mouth dryness. The optimal cut-off value (mean value of 4 salivary glands shear wave elastography results) to distinguish patients with or without pSS was 13.19 kPa with sensitivity = 97.8% and specificity = 100.0%. It was, therefore, confirmed that shear wave elastography measurement of salivary glands has strong predictive ability in pSS detection (AUC 97.8%, 95% CI 93.4-100.0%). Shear wave elastography seems to be a promising, non-invasive and simple quantitative adjunct test to support the diagnosis of pSS with good sensitivity and specificity. More extensive prospective studies are needed to standardize a study protocol.
Collapse
|
6
|
Multimodal Evaluation of Long-Term Salivary Gland Alterations in Sarcoidosis. J Clin Med 2022; 11:jcm11092292. [PMID: 35566418 PMCID: PMC9101207 DOI: 10.3390/jcm11092292] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 04/11/2022] [Accepted: 04/19/2022] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Sarcoidosis is a systemic inflammatory disease characterized by non-caseating granulomas. In addition to the lungs as classical site of affection, extrapulmonary manifestations are common, for example in the cervical lymph nodes or the salivary glands. The aim of this investigation is the analysis of the long-term course of glandular symptoms and the sonographic evaluation of long-term salivary gland changes. MATERIAL AND METHODS All patients with a diagnosis of sarcoidosis over a period of 20 years in the departments of otorhinolaryngology, rheumatology, and pneumology were identified. In addition to clinical examinations and functional evaluation of the salivary glands, a sonographic examination of the salivary glands was carried out. The changes in the area of the salivary glands were assessed using B-mode sonography and different elastographic methods with appropriate scoring systems. RESULTS A total of 76 patients were included in the study (age 35.1 ± 21.6 years). Overall, 17 patients presented with salivary gland manifestation at the time of the initial diagnosis. Of these patients, 15 received steroid therapy, 6 were also treated with another drug, and 2 patients were not treated with drugs. The time span between initial diagnosis and follow-up was 88.2 months (±83.0). At the time of the initial diagnosis, 17/17 complained of swelling of the salivary glands, 9/17 of xerostomia, and 8/17 of pain in the area of the salivary glands. At the time of follow-up, 5/17 reported swelling of the salivary glands, 6/17 reported xerostomia, and 1/17 reported pain in the salivary gland area. Sonography showed sonomorphological abnormalities of the salivary glands only in individual cases, with only mild alterations on average. CONCLUSION In summary, it can be observed that patients with initial symptoms in the area of the salivary glands, such as swelling or pain, also suffer more frequently from dry mouth and eyes. In all patients, however, these symptoms regressed over time. A previous diagnosis of sarcoidosis with involvement of the salivary glands only leads to permanent abnormalities in the area of the salivary glands in individual cases.
Collapse
|
7
|
Inhalative Treatment of Laryngitis Sicca in Patients with Sjögren's Syndrome-A Pilot Study. J Clin Med 2022; 11:jcm11041081. [PMID: 35207348 PMCID: PMC8876981 DOI: 10.3390/jcm11041081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/10/2022] [Accepted: 02/15/2022] [Indexed: 11/16/2022] Open
Abstract
Xerostomia and keratoconjunctivitis sicca are the main symptoms of Sjögren's syndrome. Often patients also suffer from laryngeal complaints, but there is a lack of specific treatment options. The aim of this study was to evaluate the effect of a liposomal inhalation therapy. Patients with Sjögren's syndrome were included and received a two-month period of liposomal inhalation therapy. The effect was evaluated by standardized questionnaires (patient-reported indices) and measurement of unstimulated whole salivary flow and glandular stiffness. Forty-five patients were included in this study. A comparison of baseline and therapeutic values demonstrated a significant improvement of the EULAR Sjögren's syndrome patient reported index (ESSPRI) with a baseline of 5.0 ± 2.1 and a therapeutic value of 4.1 ± 2.4 (p = 0.012). This improvement was mainly based on the item on dryness within this score. Overall, the therapy was well tolerated. In conclusion, an inhalative application of liposomes had a beneficial effect on the reported dryness in patients with Sjögren's syndrome. A first insight into the effect of inhalation therapy on laryngeal symptoms could thus be obtained and at the same time the basis was created on which case calculations can be carried out in the future.
Collapse
|
8
|
Jering M, Zenk J, Thölken R, Rüger H, Psychogios G. Can Ultrasound in Combination with Virtual Touch Imaging Quantification Predict the Dignity of a Parotid Tumor? ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1192-1203. [PMID: 33541749 DOI: 10.1016/j.ultrasmedbio.2020.12.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Revised: 11/20/2020] [Accepted: 12/30/2020] [Indexed: 06/12/2023]
Abstract
Pre-operative evaluation of a parotid gland tumor is crucial in guiding treatment. This study evaluates the diagnostic performance of B-mode ultrasound in combination with Virtual Touch imaging quantification (VTIQ) in the assessment of parotid lesions. A prospective study of 268 patients with parotid lesions was conducted. Pre-operative ultrasound findings and VTIQ data were compared against histologic results. Ill-defined margins on ultrasound were associated with a significantly higher risk of malignancy (odds ratio [OR] = 1224.0, 95 % confidence interval [CI]: 151.8-9872.7). Faster mean shear waves on VTIQ (OR = 1.81, 95% CI: 1.47-2.23, per 1 m/s increase) and an area with shear wave velocity >6.0 m/s involving >70 % of the lesion (OR = 19.80, 95 % CI: 6.22-63.07) were associated with higher risk of malignancy. Addition of VTIQ to routine pre-operative B-mode ultrasound can provide supplemental information on the dignity of a parotid tumor, allowing for peri-operative procedural optimization.
Collapse
Affiliation(s)
- Monika Jering
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Augsburg, Augsburg, Germany.
| | - Johannes Zenk
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Augsburg, Augsburg, Germany
| | - Rubens Thölken
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Augsburg, Augsburg, Germany
| | - Holger Rüger
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Augsburg, Augsburg, Germany
| | - Georgios Psychogios
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Augsburg, Augsburg, Germany; Department of Otolaryngology, Head and Neck Surgery, University Hospital of Ioannina, Ioannina, Greece
| |
Collapse
|
9
|
Oruk YE, Çildağ MB, Karaman CZ, Çildağ S. Effectiveness of ultrasonography and shear wave sonoelastography in Sjögren syndrome with salivary gland involvement. Ultrasonography 2021; 40:584-593. [PMID: 34058823 PMCID: PMC8446487 DOI: 10.14366/usg.21014] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 03/23/2021] [Indexed: 01/23/2023] Open
Abstract
Purpose This study investigated the effectiveness of major salivary gland ultrasonography (MSGUS) using a new grading system and shear wave elastography (SWE) in evaluating the major salivary glands of patients with Sjögren syndrome (SjS). Methods This prospectively-designed cross-sectional study included 49 SjS patients and 49 healthy controls. Major salivary glands were examined with gray-scale ultrasonography and SWE. A new grading system for salivary glands was developed using MSGUS findings. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MSGUS and shear wave velocity (SWV) values were investigated. The MSGUS grading system and SWV values were evaluated together by logistic regression analysis. A cutoff value of SWE for salivary glands was determined. Results The sensitivity, specificity, PPV, and NPV of MSGUS were 69.4%, 73.5%, 72.3%, and 70.6% for the submandibular gland and 69.4%, 65.3%, 66.7%, and 68.1% for the parotid gland, respectively. The mean SWV values of the parotid and submandibular glands were significantly higher in SjS patients than in controls (P<0.05). The sensitivity, specificity, PPV, and NPV for the submandibular gland (cutoff, 1.95 m/s) and the parotid gland (cutoff, 2.39 m/s) were 69.4%, 52%, 59.1%, and 63% and 82.7%, 83.7%, 83.5%, and 82.8%, respectively. Adding SWE to the parotid gland grading system increased the sensitivity and specificity (sensitivity, 82.7%; specificity, 83.7%). Conclusion Evaluating the salivary glands using MSGUS with a new grading system and SWE may contribute to the diagnosis of SjS. The combination of MSGUS and SWE may be a promising tool for diagnosing SjS.
Collapse
Affiliation(s)
- Yunus Emre Oruk
- Department of Diagnostic Radiology, Muğla Menteșe State Hospital, Muğla, Turkey.,Department of Diagnostic and Interventional Radiology, Adnan Menderes University, Aydin, Turkey
| | - Mehmet Burak Çildağ
- Department of Diagnostic and Interventional Radiology, Adnan Menderes University, Aydin, Turkey
| | - Can Zafer Karaman
- Department of Diagnostic and Interventional Radiology, Adnan Menderes University, Aydin, Turkey
| | - Songül Çildağ
- Department of Immunology and Allergy, Adnan Menderes University, Aydin, Turkey
| |
Collapse
|
10
|
Martino M, Fodor D, Fresilli D, Guiban O, Rubini A, Cassoni A, Ralli M, De Vincentiis C, Arduini F, Celletti I, Pacini P, Polti G, Polito E, Greco A, Valentini V, Sorrenti S, D'Andrea V, Masciocchi C, Barile A, Cantisani V. Narrative review of multiparametric ultrasound in parotid gland evaluation. Gland Surg 2020; 9:2295-2311. [PMID: 33447581 DOI: 10.21037/gs-20-530] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Disorders affecting parotid gland represent a heterogeneous group comprising congenital, inflammatory and neoplastic diseases which show a focal or diffuse pattern of appearance. The differentiation of neoplastic from non-neoplastic conditions of parotid glands is pivotal for the diagnostic imaging. Frequently there is evidence of overlapping between the clinical and the imaging appearance of the various pathologies. The parotid gland is also often object of study with the combination of different techniques [ultrasound-computed tomography-magnetic resonance imaging (US-CT-MRI), ex.]. Compared to other dominant methods of medical imaging, US has several advantages providing images in real-time at lower cost, and without harmful use of ionizing radiation and of contrast enhancement. B-mode US, and the microvascular pattern color Doppler are usually used as first step evaluation of parotid lesions. Elastography and contrast-enhanced US (CEUS) has opened further possible perspectives to improve the differentiation between benign and malignant parotid lesions. The characterization of the parotid tumors plays a crucial role for their treatment planning and for the prediction of possible surgical complications. We present, here an updated review of the most recurrent pathologies of parotid gland focusing on the diagnostic power of multiparametric US including CEUS and ultrasound elastography (USE); limitations, advantages and the main key-points will be presented.
Collapse
Affiliation(s)
- Milvia Martino
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Daniela Fodor
- 2nd Internal Medicine Department, "Iuliu Hațieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Daniele Fresilli
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Olga Guiban
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | | | - Andrea Cassoni
- Department of Maxillofacial Surgery, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Massimo Ralli
- Department of Sense Organs, Sapienza University of Rome, Rome, Italy
| | | | - Federico Arduini
- Department of Radiology, Ospedale Santa Maria del Carmine, Rovereto, Italy
| | - Ilaria Celletti
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Patrizia Pacini
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Giorgia Polti
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Eleonora Polito
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Antonio Greco
- Department of Sense Organs, Sapienza University of Rome, Rome, Italy
| | - Valentino Valentini
- Department of Maxillofacial Surgery, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - Salvatore Sorrenti
- Department of Surgical Sciences, "Sapienza" University of Rome, Rome, Italy
| | - Vito D'Andrea
- Department of Surgical Sciences, "Sapienza" University of Rome, Rome, Italy
| | - Carlo Masciocchi
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Antonio Barile
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Vito Cantisani
- Department of Radiological Sciences, Oncology and Pathology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| |
Collapse
|
11
|
Abstract
Primary Sjögren's syndrome (pSS) is an autoimmune disease, which involves salivary glands (SG) and extra glandular organs. Today, Sjögren's patients' diagnosis is based on classification criteria taking into account five objective tests, including histology, immunology, two ophthalmological tests, and salivary flow evaluation. To date, the challenge is to find the right imaging tool for diagnosis, follow up, and prognosis of pSS. The objective of this review is to describe as to what are these imaging modalities and particularly the place and validity of salivary glands ultrasonography (SGUS) in the diagnosis and follow-up strategy of patients with suspected pSS. Moreover, new noninvasive tools are emerging, including elastography, a new ultrasonography technique that provides an estimate of tissue elasticity, MRI, MR sialography, and 18 fluorodeoxyglucose-positron emission tomography. Although new imaging opportunities are available, SGUS should be the first-line choice in pSS because of its accessibility, feasibility over time, and sensitivity to change.
Collapse
|
12
|
Moisoiu V, Badarinza M, Stefancu A, Iancu SD, Serban O, Leopold N, Fodor D. Combining surface-enhanced Raman scattering (SERS) of saliva and two-dimensional shear wave elastography (2D-SWE) of the parotid glands in the diagnosis of Sjögren's syndrome. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 235:118267. [PMID: 32276224 DOI: 10.1016/j.saa.2020.118267] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 03/06/2020] [Accepted: 03/15/2020] [Indexed: 06/11/2023]
Abstract
In this study, we combine the molecular structural information gained by SERS of saliva samples with the morphological data given by two-dimensional shear wave elastography (2D-SWE) (SuperSonic Imagine, Aixplorer) of parotid glands in the case of n = 31 patients with Sjögren's syndrome (SjS) and n = 22 controls, with the aim to discriminate between the two groups. The overall classification accuracy yielded by a hybrid principal component analysis-linear discriminant analysis (PCA-LDA) model based on both SERS and elastography (81%) was superior to that yielded by SERS spectra alone (75%) and elastography data alone (71%). This preliminary study is the first report on the use of 2D-SWE of parotid glands for the diagnosis of SjS as well as the first to describe the diagnosis of SjS based on the SERS spectra of dried saliva samples, the results suggesting that the strategy of combining the two methods could improve the diagnosis of SjS.
Collapse
Affiliation(s)
- Vlad Moisoiu
- Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania
| | - Maria Badarinza
- 2(nd) Department of Internal Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Andrei Stefancu
- Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania; MEDFUTURE Research Center for Advanced Medicine, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Stefania D Iancu
- Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania
| | - Oana Serban
- 2(nd) Department of Internal Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Nicolae Leopold
- Faculty of Physics, Babeș-Bolyai University Cluj-Napoca, Romania; MEDFUTURE Research Center for Advanced Medicine, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
| | - Daniela Fodor
- 2(nd) Department of Internal Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
| |
Collapse
|
13
|
Arslan S, Durmaz MS, Erdogan H, Esmen SE, Turgut B, Iyisoy MS. Two-Dimensional Shear Wave Elastography in the Assessment of Salivary Gland Involvement in Primary Sjögren's Syndrome. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:949-956. [PMID: 31763717 DOI: 10.1002/jum.15179] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 10/29/2019] [Accepted: 11/07/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES The aim of this study was to investigate the diagnostic performance of two-dimensional (2D) shear wave elastography (SWE) in the assessment of salivary gland involvement in primary Sjögren's syndrome (pSS). METHODS Fifty-three patients with pSS and 30 healthy volunteers were included. The echogenicity of all submandibular and parotid glands was evaluated with B-mode ultrasound, and their elasticity was assessed with 2D SWE. The mean and standard deviation of the shear wave speed and elasticity modes on 2D SWE were calculated. RESULTS The mean shear wave speed and elasticity mode values for the submandibular and parotid glands were significantly higher in the patients with pSS (P < .05). The mean elasticity of the shear wave speed mode was best able to differentiate the parotid glands of patients with pSS from those of healthy volunteers at a cutoff value of 2.48 m/s, whereas the mean elasticity of the elasticity mode was best able to differentiate the submandibular glands of patients with pSS from those of healthy volunteers at a cutoff value of 21 kPa. CONCLUSIONS Two-dimensional SWE is an effective technique for assessment of the parenchyma of the salivary glands in patients with pSS and predicts interstitial fibrosis and the severity of histologic damage.
Collapse
Affiliation(s)
- Serdar Arslan
- Department of Radiology, Division of Neuroradiology, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey (S.A.)
| | - Mehmet Sedat Durmaz
- Department of Radiology, Selcuk University School of Medicine, Konya, Turkey (M.S.D.)
| | - Hasan Erdogan
- Department of Radiology, Aksaray University Training and Research Hospital, Aksaray, Turkey (H.E.)
| | - Serpil Ergulu Esmen
- Departments of Rheumatology, University of Health Science, Konya Training and Research Hospital, Konya, Turkey (S.E.E)
| | - Bekir Turgut
- Department of Radiology, University of Health Science, Konya Training and Research Hospital, Konya, Turkey (B.T.)
| | - Mehmet Sinan Iyisoy
- and Department of Medical Education and Informatics, Necmettin Erbakan University School of Medicine, Konya, Turkey (M.S.I.)
| |
Collapse
|
14
|
The Utility of Major Salivary Gland Ultrasonographic Parameters in the Diagnosis of Sjögren Syndrome. DISEASE MARKERS 2020; 2019:1716848. [PMID: 31929838 PMCID: PMC6942831 DOI: 10.1155/2019/1716848] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Accepted: 11/25/2019] [Indexed: 02/08/2023]
Abstract
Objective To investigate ultrasonographically the salivary glands and to correlate ultrasonographic parameters with focus score, serum beta-2-microglobulin, and stimulated salivary flow rate. Material and Methods 32 patients with primary Sjögren's syndrome (pSS) and 32 healthy controls were enrolled in this case-control study, performed in the Department of Internal Medicine, Division of Rheumatology, "Victor Babeș" University of Medicine and Pharmacy, Timișoara, Romania. All the patients and controls were examined by salivary gland ultrasonography (B-mode, color and spectral Doppler, and sonoelastography), determining the following parameters: salivary gland ultrasonography (SGUS) score, resistive index (RI) of transverse facial artery, and shear wave velocity (SWV). Serum beta-2-microglobulin and stimulated saliva amount were determined in all the patients and controls. Minor salivary gland biopsy with focus score assessment was done in pSS patients. Results Patients with pSS presented higher SGUS score and parotid and submandibular SWV and reduced RI of transverse facial artery than controls (p < 0.0001). In pSS patients, statistically significant correlations were identified between assessed ultrasonographic parameters and focus score, serum beta-2-microglobulin, and respective stimulated saliva flow (p < 0.0001). Conclusions This study highlighted statistically significant correlations between salivary gland ultrasonographic parameters and focus score, serum beta-2-microglobulin, and stimulated saliva flow.
Collapse
|
15
|
Elbeblawy YM, Eshaq Amer Mohamed M. Strain and shear wave ultrasound elastography in evaluation of chronic inflammatory disorders of major salivary glands. Dentomaxillofac Radiol 2019; 49:20190225. [PMID: 31770001 DOI: 10.1259/dmfr.20190225] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVE The aim of this study was to assess chronic inflammatory conditions of major salivary glands by ultrasound elastography. METHODS 21 patients with chronic inflammatory conditions of major salivary glands and 21 healthy adult volunteers were included in this study. All participants underwent B-mode sonography and ultrasound elastography. The diagnostic performance of strain ratio and shear wave velocity was evaluated by sensitivity and specificity at the optimum cutoff point and the area under the receiver operating characteristic curve. RESULTS Cases showed statistically significant higher median strain ratio of parotid and submandibular gland than control group (p-value = 0.001). Total cases showed statistically significant higher median scores than control group (p-value < 0.001). At cut-off value of (1.13); diagnostic accuracy, sensitivity and specificity were 97.6, 95.2 and 100% respectively with AUROC 0.954 and confidence interval: 0.840-0.995. Cases showed statistically significant higher median shear wave velocity of parotid gland than control group (p-value = 0.022), with no statistically significant difference in submandibular gland in the two groups (p-value = 0.216). Total cases showed statistically significant higher median scores than control group (p-value < 0.001). At cut-off value of (23.5), diagnostic accuracy was 78.6% with a sensitivity of 81% and specificity of 76.2% with 0.819 AUROC and onfidence interval :0.669-0.920. CONCLUSION Our initial experience suggests that elastography may be potentially useful for diagnosis of chronic inflammatory conditions of the major salivary glands. This conclusion needs to be further validated large sample studies.
Collapse
|
16
|
Abstract
OBJECTIVE There are different imaging techniques to assess the parotid glands (i.e., sialography, salivary gland scintigraphy) in patients with Sjögren syndrome (SS). However, their use is limited by the invasive character or high cost. Ultrasound (US) is gaining interest by rheumatologists as a complementary diagnostic tool for SS. To date, there is an increasing body of evidence supporting its sensitivity in the assessment of salivary glands in SS. The aim of our study was to analyze the potential role of US as a diagnostic and prognostic tool in SS and to discuss existing evidence to support its application use. METHODS A systematic search was performed in the electronic database PubMed, using the following search terms: (salivary glands OR parotid glands OR submandibular glands) AND Sjögren's syndrome AND (ultrasonography OR ultrasound OR sonography). Titles, abstracts, and full reports were systematically screened. RESULTS The results of the studies analyzed in this review show encouraging results in terms of accuracy, validity, and diagnostic value, which leads us to believe that in the future US could become the reference imaging tool to assess SS. The studies include a small cohort of patients, and there is no standardized approach in terms of US techniques for the assessment of salivary glands. CONCLUSIONS Ultrasound of major salivary glands is a useful tool for diagnosis, prognostic evaluation, and response to treatment in SS. The use of this imaging technology is still under development, and more multicentric studies are needed to validate this tool.
Collapse
|
17
|
Hofauer B, Chaker A, Thürmel K, Knopf A. [Manifestations of autoimmune disorders in otorhinolaryngology : Classical symptoms and diagnostic approach]. HNO 2019; 65:695-708. [PMID: 28710538 DOI: 10.1007/s00106-017-0380-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Manifestations of autoimmune disorders represent a diagnostic challenge. Many autoimmune disorders show typical manifestations in the ear, nose and throat and should be taken into account in the differential diagnosis. Sjogren's syndrome, various vasculitides and sarcoidosis represent the most common autoimmune disorders in otorhinolaryngology, but IgG4-related diseases, relapsing polychondritis and autoimmune disorders of the mucosa are also observed. Autoimmune diseases can lead to sensorineural deficits. Both hypo- and hyperthyroidism can be caused by autoimmune disorders. The diagnosis is usually based on the corresponding classification criteria, whose correct application can facilitate the clarification of these diseases.
Collapse
Affiliation(s)
- B Hofauer
- Hals-Nasen-Ohren-Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Ismaningerstr. 22, 81675, München, Deutschland.
| | - A Chaker
- Hals-Nasen-Ohren-Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Ismaningerstr. 22, 81675, München, Deutschland
| | - K Thürmel
- Rheumatologie, II. Medizinische Klinik, Klinikum rechts der Isar, Technische Universität München, München, Deutschland
| | - A Knopf
- Hals-Nasen-Ohren-Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Ismaningerstr. 22, 81675, München, Deutschland
| |
Collapse
|
18
|
Martins-Rocha T, Azzolin I, Serban T, Massazza G, Iagnocco A. New applications of sonoelastography in rheumatology: where are we now? Rheumatology (Oxford) 2019; 58:765-769. [PMID: 30281087 DOI: 10.1093/rheumatology/key296] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 08/22/2018] [Indexed: 12/19/2022] Open
Abstract
Ultrasound elastography (UE) is a non-invasive imaging method that allows the assessment of tissue elastic property. Different UE techniques are currently available (i.e. strain UE and acoustic radiation force impulse UE), with several potential clinical applications. Recent studies investigated the role of UE in two systemic rheumatic diseases and psoriasis. This research added interesting information to the already known applications of UE in the assessment of tendinopathies. In SS, acoustic radiation force impulse UE has shown a potential role in the diagnosis of the disease, with lower sensitivity than and similar specificity to salivary gland histology. In SSc, a potential use of UE in screening pre-clinical disease has been reported. In psoriasis, the use of strain UE in evaluating treatment response has been highlighted. UE is a promising tool in rheumatology, with a potential role in the evaluation of various tissues and pathologies.
Collapse
Affiliation(s)
| | - Irene Azzolin
- Division of Physical Medicine and Rehabilitation, MFRU - Università degli Studi di Torino
| | - Teodora Serban
- Academic Rheumatology Center, Division of Physical Medicine and Rehabilitation and Dipartimento Scienze Cliniche e Biologiche, Università degli Studi di Torino, Turin, Italy
| | - Giuseppe Massazza
- Division of Physical Medicine and Rehabilitation, MFRU - Università degli Studi di Torino
| | - Annamaria Iagnocco
- Academic Rheumatology Center, Division of Physical Medicine and Rehabilitation and Dipartimento Scienze Cliniche e Biologiche, Università degli Studi di Torino, Turin, Italy
| |
Collapse
|
19
|
Rahatli FK, Turnaoglu H, Iyidir OT, Kirnap NG, Haberal KM, Aydın E, Uslu N. Assessment of Parotid and Submandibular Glands With Shear Wave Elastography Following Radioactive Iodine Therapy for Papillary Thyroid Carcinoma. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:357-362. [PMID: 30027680 DOI: 10.1002/jum.14695] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 04/18/2018] [Accepted: 04/19/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVES Papillary thyroid carcinoma (PTC) is the most common thyroid malignancy. Radioactive iodine (RAI) therapy is used for remnant ablation following thyroidectomy. Side effects such as dysphagia, xerostomia, and sialoadenitis may occur. We aimed to determine the differences in the parotid and submandibulary glands between healthy patients and patients with PTC who had undergone RAI therapy and have dry mouth symptoms using both shear wave elastography and ultrasonography. METHODS We enrolled 30 patients with PTC who had undergone RAI therapy following surgery and 30 healthy controls. Ultrasonography and shear wave elastography of submandibular and parotid glands were performed. The volume of the submandibular glands and the thickness of parotid glands were determined. Ten independent measurements were obtained from each gland, with the region of interest placed at different points on the glands. The mean shear wave velocities (SWVs) were calculated and compared between the patients and controls. RESULTS In the PTC group, there was a significant reduction in the volume of the submandibular glands (P < .05) and in the thickness of the parotid glands (P < .05) compared with the control group. The mean SWVs of the parotid glands and submandibular glands were significantly higher in the PTC group compared with the control group (P < .0001). The SWVs of the parotid glands were higher than the SWVs of the submandibular glands (P < .0001). CONCLUSIONS Shear wave elastography could be a noninvasive and easy assessment method of parotid and submandibular glands in patients who had undergone RAI therapy and experience dry mouth.
Collapse
Affiliation(s)
- Feride Kural Rahatli
- Department of Radiology, Faculty of Medicine, Baskent University, Ankara, Turkey
| | - Hale Turnaoglu
- Department of Radiology, Faculty of Medicine, Baskent University, Ankara, Turkey
| | - Ozlem Turhan Iyidir
- Department of Endocrinology, Faculty of Medicine, Baskent University, Ankara, Turkey
| | - Nazli Gulsoy Kirnap
- Department of Endocrinology, Faculty of Medicine, Baskent University, Ankara, Turkey
| | - Kemal Murat Haberal
- Department of Radiology, Faculty of Medicine, Baskent University, Ankara, Turkey
| | - Erdinç Aydın
- Department of Ear, Nose, and Throat, Faculty of Medicine, Baskent University, Ankara, Turkey
| | - Nihal Uslu
- Department of Radiology, Faculty of Medicine, Baskent University, Ankara, Turkey
| |
Collapse
|
20
|
Pia LJ, Juan BM, Frank P, Angela AA, Jose G, Juan de Dios BS. Is sonoelastography a helpful method of evaluation to diagnose Sjögren's syndrome? Int J Rheum Dis 2018; 22:175-181. [PMID: 30187679 DOI: 10.1111/1756-185x.13373] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2017] [Revised: 03/27/2018] [Accepted: 07/29/2018] [Indexed: 12/19/2022]
Affiliation(s)
- López-Jornet Pia
- Instituto Murciano de Investigación Biosanitaria (IMIB-Arrixaca-UMU); Hospital Clínico Universitario Virgen de la Arrixaca; Murcia Spain
- Oral Medicine Hospital General Universitario JM Morales Meseguer University Murcia; Murcia Spain
| | - Berna Mestre Juan
- Department of Radiology; Virgen de la Arrixaca University Hospital; El Palmar (Murcia); Spain University Murcia; Murcia Spain
| | - Pina Frank
- Rheumatology Unit; Hospital General Universitario JM Morales Meseguer; Murcia Spain
| | - Aniorte Alegria Angela
- Oral Medicine Hospital General Universitario JM Morales Meseguer University Murcia; Murcia Spain
| | - Gálvez Jose
- Rheumatology Unit; Hospital General Universitario JM Morales Meseguer; Murcia Spain
| | - Berna Serna Juan de Dios
- Department of Radiology; Virgen de la Arrixaca University Hospital; El Palmar (Murcia); Spain University Murcia; Murcia Spain
| |
Collapse
|
21
|
|
22
|
Cindil E, Oktar SO, Akkan K, Sendur HN, Mercan R, Tufan A, Ozturk MA. Ultrasound elastography in assessment of salivary glands involvement in primary Sjögren's syndrome. Clin Imaging 2018; 50:229-234. [PMID: 29689477 DOI: 10.1016/j.clinimag.2018.04.011] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 04/11/2018] [Accepted: 04/12/2018] [Indexed: 12/17/2022]
Abstract
OBJECTIVE Our study aimed to assess the pathological sonoelastographic changes in the major salivary glands and to demonstrate the diagnostic effectiveness of Sonoelastography as an additional method to US in Sjögren's syndrome. METHODS Fifty eight patients with primary Sjögren's syndrome (pSS) were selected according to the American-European Consensus Group Classification criteria. Twenty five healthy volunteers involved in this study. All patients were evaluated with B-mode and elastography by using Hitachi EUB 7500 digital ultrasound equipment. All subjects were female. The sonoelastography examination, which allowed us to assess the elasticity of the parenchyma, was performed and strain ratios were measured by comparing with the adjacent tissues. RESULTS Statistically significant differences were found between the pSS and control groups for the elastographic scores and strain ratios (p < 0.001). The highest sensitivity and specificity levels were obtained when the strain ratio cut-off value was taken as 1.55 for the submandibular gland and 2.45 for the parotid gland (sensitivity and specificity were 83% and 88% respectively for the submandibular gland and 83% and 92% respectively for the parotid gland). However, no statistically significant differences were found between the disease duration and the elasticity scores or strain ratios in pSS group (p > 0.05). CONCLUSION US examination is an efficient method to assess major salivary gland involvement in the diagnosis of pSS. Sonoelastography is a modality which can contribute to the diagnosis by improving specificity in the differential diagnosis of pSS. Strain ratio measurement, which is a semi-quantitative method, increases the diagnostic effectiveness by providing high sensitivity, specificity, and negative predictive values.
Collapse
Affiliation(s)
- Emetullah Cindil
- Gazi University Faculty of Medicine, Department of Radiology, Ankara, Turkey.
| | - Suna Ozhan Oktar
- Gazi University Faculty of Medicine, Department of Radiology, Ankara, Turkey
| | - Koray Akkan
- Gazi University Faculty of Medicine, Department of Radiology, Ankara, Turkey
| | - Halit Nahit Sendur
- Gazi University Faculty of Medicine, Department of Radiology, Ankara, Turkey
| | | | - Abdurrahman Tufan
- Gazi University Faculty of Medicine, Department of Rheumatology, Ankara, Turkey
| | - Mehmet Akif Ozturk
- Gazi University Faculty of Medicine, Department of Rheumatology, Ankara, Turkey
| |
Collapse
|
23
|
Kimura-Hayama E, Criales-Vera S, Azpeitia-Espinosa L, Pacheco-Molina C, Reyes E, Lima G, Hernandez-Ramirez D, Llorente L, Hernandez-Molina G. Elastographic ultrasound: an additional image tool in Sjögren's syndrome. Int J Rheum Dis 2018; 21:1293-1300. [PMID: 29624878 DOI: 10.1111/1756-185x.13292] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
AIM To evaluate the stiffness of parotid and submandibular glands using elastography ultrasound and to correlate it with B-mode ultrasonographical, clinical and serological features, salivary profibrotic and inflammatory chemokines, and salivary gland fibrosis. METHODS We performed B-mode and elastography ultrasound of major salivary glands of 26 patients with primary Sjögren's syndrome. We registered the shear wave velocity (SWV) and correlated it with the morphologic ultrasonographic changes assessed by the Hocevar scale. We assessed the European League Against Rheumatism (EULAR) Sjögren's Syndrome Disease Activity Index (ESSDAI), EULAR Sjögren's Syndrome Patient Reported Index (ESSPRI), non-stimulated whole salivary flow rate (NSWSF), C3 and C4 levels, anti-Ro/La antibodies, salivary inflammatory (C-X-C motif ligand 13 [CXCL13], CXCL10, CXCL8, C-C motif ligand 2 [CCL2], interleukin 10 [IL-10] and IL-6) and pro-fibrotic (CXCL14, CCL28, tumor necrosis factor-related apoptosis-inducing ligand and transforming growth factor β) chemokines and cytokines and evaluated the presence of fibrosis in the minor salivary gland. RESULTS Ninety-two percent of patients were women; mean age was 51.1 ± 11 years; median disease duration was 6.1 years; 92.3% had oral symptoms and 26.9% fibrosis. The median B-mode score was 22.2 points and the median SWV 2.5 m/s (τ = 0.53, P = 0.001). The SWV correlated with the NSWSF (τ = -0.53, P = 0.001), ESSDAI (τ = 0.31, P = 0.03), glandular ESDDAI domain (τ = 0.36, P = 0.02), C4 levels (τ = -0.32, P = 0.04), salivary CXCL13 (τ = 0.29, P = 0.03) and CXCL10 (τ = 0.30, P = 0.003), but not with age and fibrosis. CONCLUSION WV correlated with the B-mode ultrasound score, systemic and glandular activity and in a large degree with CXCL10, an inflammatory chemokine, but not with fibrosis. An increased SWV might represent chronic glandular inflammation rather than fibrotic changes in these patients.
Collapse
Affiliation(s)
- Eric Kimura-Hayama
- Department of Radiology, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, Mexico
| | - Sergio Criales-Vera
- Department of Radiology, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, Mexico
| | - Luis Azpeitia-Espinosa
- Department of Radiology, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, Mexico
| | - Carlos Pacheco-Molina
- Immunology and Rheumatology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Edgardo Reyes
- Pathology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Guadalupe Lima
- Immunology and Rheumatology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Diego Hernandez-Ramirez
- Immunology and Rheumatology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Luis Llorente
- Immunology and Rheumatology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| | - Gabriela Hernandez-Molina
- Immunology and Rheumatology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico
| |
Collapse
|
24
|
Takagi Y, Nakamura H, Sumi M, Shimizu T, Hirai Y, Horai Y, Takatani A, Kawakami A, Eida S, Sasaki M, Nakamura T. Combined classification system based on ACR/EULAR and ultrasonographic scores for improving the diagnosis of Sjögren's syndrome. PLoS One 2018; 13:e0195113. [PMID: 29614092 PMCID: PMC5882118 DOI: 10.1371/journal.pone.0195113] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Accepted: 03/17/2018] [Indexed: 12/18/2022] Open
Abstract
We retrospectively evaluated the effectiveness of combined use of salivary gland ultrasonography (US) and the 2016 American College of Rheumatology/European League Against Rheumatic Disease (ACR/EULAR) classification criteria for improving the diagnostic efficiency in patients with Sjögren’s syndrome (SS). A US-based salivary gland disease grading system was developed using a cohort comprising 213 SS or non-SS patients who fulfilled the minimum requirements for classifying SS based on the American-European Consensus Group (AECG) and ACR criteria. Using 62 SS or non-SS patients from the 213 patients and who had also undergone all the 5 examinations needed for the ACR/EULAR classification, we compared the diagnostic accuracy of various combinations of the ACR/EULAR and US classifications for diagnosing SS, using the clinical diagnosis of SS by rheumatologists as the gold standard. The ACR/EULAR criteria discriminated clinical SS patients with 77% and 79% accuracy for those with primary or secondary SS and for those with primary SS, respectively. However, the integrated score system of the ACR/EULAR and US classifications yielded 92% and 93% accuracy for these 2 SS patient groups, respectively, provided that US score of 3 was assigned to patients with US grade ≥2, and then patients with integrated threshold score of ≥5 were diagnosed as SS. Cross-validation also indicated improved accuracy of the integrated ACR/EULAR and US score system (91.9 and 93.0% for primary/secondary and primary SS patients, respectively) over that by the ACR/EULAR criteria alone. (74.2 and 86.0%, respectively). The integrated ACR/EULAR and US scoring system can improve the diagnosis of patients with clinical SS.
Collapse
Affiliation(s)
- Yukinori Takagi
- Department of Radiology and Cancer Biology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Hideki Nakamura
- Department of Immunology and Rheumatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Misa Sumi
- Department of Radiology and Cancer Biology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Toshimasa Shimizu
- Department of Immunology and Rheumatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Yasuko Hirai
- Department of Immunology and Rheumatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Yoshiro Horai
- Department of Immunology and Rheumatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
- Clinical Research Center, National Hospital Organization (NHO) Nagasaki Medical Center, Nagasaki, Japan
| | - Ayuko Takatani
- Department of Immunology and Rheumatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Atsushi Kawakami
- Department of Immunology and Rheumatology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Sato Eida
- Department of Radiology and Cancer Biology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Miho Sasaki
- Department of Radiology and Cancer Biology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| | - Takashi Nakamura
- Department of Radiology and Cancer Biology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
- * E-mail:
| |
Collapse
|
25
|
Knopf A, Heiser C, Karasoy Ö, Hofauer B, Bier H, Mansour N. Bipolar dissection technique in parotid gland surgery. Acta Otolaryngol 2017; 137:1210-1214. [PMID: 28741402 DOI: 10.1080/00016489.2017.1354396] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Parotid gland surgery (PGS) has to manage the balancing act between sufficient radicality and preservation of functional structures. While many studies evaluate post-therapeutic complication due to different extent of surgery, the current study introduces bipolar dissection (BP) being a fast and safe preparation technique. METHODS Analysis of clinical parameters (age, sex, tumour entity, treatment modalities, facial nerve palsy, bleeding, saliva fistula and Frey's syndrome) of 319 consecutively included patients who underwent extracapsular dissection and superficial/total/radical parotidectomy. Subgroup analysis was done according to the preparation technique (cold vs BP). RESULTS Facial nerve palsy rate increased with the extent of PGS (p < .0001). There were no differences in the risk of post-operative bleeding, salivary fistula and Frey's syndrome. BP resulted in a significant reduction of operation time (p = .04), postoperative bleeding (p = .001) and salivary fistula (p = .045) when compared with cold preparation. CONCLUSIONS Ubiquitous available BP allows fast and safe PGS regardless its extent.
Collapse
Affiliation(s)
- Andreas Knopf
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der s Isar, Technische Universität München, München, Germany
| | - Clemens Heiser
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der s Isar, Technische Universität München, München, Germany
| | - Özlem Karasoy
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der s Isar, Technische Universität München, München, Germany
| | - Benedikt Hofauer
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der s Isar, Technische Universität München, München, Germany
| | - Henning Bier
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der s Isar, Technische Universität München, München, Germany
| | - Naglaa Mansour
- Department of Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der s Isar, Technische Universität München, München, Germany
| |
Collapse
|
26
|
McQueen AS, Bhatia KS. Head and neck ultrasound: technical advances, novel applications and the role of elastography. Clin Radiol 2017; 73:81-93. [PMID: 28985885 DOI: 10.1016/j.crad.2017.08.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 08/10/2017] [Accepted: 08/14/2017] [Indexed: 01/25/2023]
Abstract
High-resolution ultrasound (US) provides superb anatomical detail in the superficial anatomy of the neck and has become the first-line imaging investigation for neck lumps and a crucial component of clinical pathways. In this article, a wide range of advances in neck US are described with a focus on the emerging role of ultrasound elastography. Selected examples of clinical utility are presented across a spectrum of scenarios with discussion of newer applications, service delivery, and training issues. The changing role of the neck ultrasound practitioner and the future of the technique in the head and neck are considered.
Collapse
Affiliation(s)
- A S McQueen
- Department of Radiology, Freeman Hospital, Newcastle upon Tyne NHS Foundation Trust, Newcastle, UK.
| | - K S Bhatia
- Department of Radiology, St. Mary's Hospital, Imperial College Healthcare NHS Trust, London, UK.
| |
Collapse
|
27
|
Knopf A, Cortolezis N, Bas M, Mansour N, Hofauer B. Multimodal ultrasonographic algorithm in the differentiation of submandibular masses. Acta Otolaryngol 2017; 137:640-645. [PMID: 28084145 DOI: 10.1080/00016489.2016.1269363] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
CONCLUSION The multimodal diagnostic algorithm is a simple diagnostic tool in the pre-operative assessment of submandibular masses that enables one-stage surgical concepts. BACKGROUND The pre-operative assessment of submandibular masses is of major clinical impact. This study assesses the diagnostic utility of a newly introduced diagnostic algorithm in the differentiation of submandibular masses based on epidemiological and B-mode ultrasonographic data. METHODS One hundred and eighty-eight patients with submandibular triangle masses were included. Epidemiological and ultrasonographic data of 128 consecutively included patients were assessed and structured in a multimodal algorithm. The diagnostic algorithm was prospectively validated in a further 60 patients. RESULTS Single epidemiological and ultrasonographic data do not reliably predict the lesional entity. The multimodal diagnostic algorithm achieved a diagnostic sensitivity/specificity of 100%/100% in sialolithiasis, 44%/100% in benign submandibular gland diseases (BSD), 94%/96% in nodal lymphoma/unspecific lymphadenitis, and 91%/84% in carcinomas. Reduced sensitivity in BSD or specificity in carcinomas increased after intra-operative fresh frozen section in patients suspected for BSD.
Collapse
Affiliation(s)
- Andreas Knopf
- Department of Otorhinolaryngology/Head and Neck Surgery, Technische Universität München, München, Germany
| | - Nikolaus Cortolezis
- Department of Otorhinolaryngology/Head and Neck Surgery, Technische Universität München, München, Germany
| | - Murat Bas
- Department of Otorhinolaryngology/Head and Neck Surgery, Technische Universität München, München, Germany
| | - Naglaa Mansour
- Department of Otorhinolaryngology/Head and Neck Surgery, Technische Universität München, München, Germany
| | - Benedikt Hofauer
- Department of Otorhinolaryngology/Head and Neck Surgery, Technische Universität München, München, Germany
| |
Collapse
|
28
|
Beckman KA, Luchs J, Milner MS, Ambrus JL. The Potential Role for Early Biomarker Testing as Part of a Modern, Multidisciplinary Approach to Sjögren's Syndrome Diagnosis. Adv Ther 2017; 34:799-812. [PMID: 28283891 DOI: 10.1007/s12325-017-0501-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Indexed: 02/06/2023]
Abstract
Sjögren's syndrome (SS) is a chronic and progressive multisystem autoimmune disease typically managed by rheumatologists. Diagnostic delays are common, due in large part to the non-specific and variable nature of SS symptoms and the slow progression of disease. The hallmark characteristics of SS are dry eye and dry mouth, but there are a broad range of other possible symptoms such as joint and muscle pain, skin rashes, chronic dry cough, vaginal dryness, extremity numbness or tingling, and disabling fatigue. Given that dry eye and dry mouth are typically the earliest presenting complaints, eye care clinicians and dental professionals are often the first point of medical contact and can provide critical collaboration with rheumatologists to facilitate both timely diagnosis and ongoing care of patients with SS. Current diagnostic criteria advocated by the American College of Rheumatology are predicated on the presence of signs/symptoms suggestive of SS along with at least two objective factors such as traditional biomarker positivity, salivary gland biopsy findings, and/or presence of keratoconjunctivitis sicca. Traditional biomarkers for SS include the autoantibodies anti-Sjögren's syndrome-related antigen A (SS-A/Ro), anti-Sjögren's syndrome-related antigen B (SS-B/La), antinuclear antibody (ANA) titers, and rheumatoid factor (RF). While diagnostically useful, these biomarkers have low specificity for SS and are not always positive, especially in early cases of SS. Several newly-identified biomarkers for SS include autoantibodies to proteins specific to the salivary and lacrimal glands [SP-1 (salivary gland protein-1), PSP (parotid secretory protein), CA-6 (carbonic anhydrase VI)]. Data suggest that these novel biomarkers may appear earlier in the course of disease and are often identified in cases that test negative to traditional biomarkers. The Sjö® test is a commercially available diagnostic panel that incorporates testing for traditional SS biomarkers (anti-SS-A/Ro, anti-SS-B/La, ANA, and RF), as well as three novel, proprietary early biomarkers (antibodies to SP-1, PSP, and CA-6) which provide greater sensitivity and specificity than traditional biomarker testing alone. Timely diagnosis of SS requires appropriate clinical vigilance for potential SS symptoms, referral and collaborative communication among rheumatology, ophthalmology, and oral care professions, and proactive differential work-up that includes both physical and laboratory evaluations.
Collapse
Affiliation(s)
- Kenneth A Beckman
- Comprehensive EyeCare of Central Ohio, Westerville, OH, USA.
- Ohio State University, Columbus, OH, USA.
| | - Jodi Luchs
- Hofstra University School of Medicine, Hempstead, NY, USA
- South Shore Eye Care, Wantagh, NY, USA
| | - Mark S Milner
- The Eye Center of Southern Connecticut, PC, Hamden, CT, USA
- Yale University School of Medicine, New Haven, CT, USA
| | - Julian L Ambrus
- Division of Allergy, Immunology and Rheumatology, Department of Medicine, SUNY at Buffalo School of Medicine, Buffalo, NY, USA
| |
Collapse
|
29
|
[Swelling of the submandibular and parotid glands : A description of possible differential diagnoses]. HNO 2017; 64:333-48. [PMID: 27160691 DOI: 10.1007/s00106-016-0158-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Swelling of single or multiple major salivary glands can be caused by various local or systemic diseases. In differential diagnosis, congenital cystic or vascular malformations should be considered, as well as infectious or tumorous alterations. Salivary duct obstructions due to sialolithiasis or stenosis can cause salivary gland enlargement. Multiple systemic diseases can have manifestations in the parotid or submandibular glands. As therapy varies from cause to cause, knowledge of the different potential diagnoses is crucial.
Collapse
|
30
|
Chen S, Wang Y, Chen S, Wu Q, Chen S. Virtual Touch Quantification of the Salivary Glands for Diagnosis of Primary Sjögren Syndrome. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:2607-2613. [PMID: 27872417 DOI: 10.7863/ultra.16.01085] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 02/24/2016] [Accepted: 03/13/2016] [Indexed: 02/05/2023]
Abstract
OBJECTIVES To investigate the value of salivary gland stiffness measured by Virtual Touch quantification (VTQ; Siemens Medical Solutions, Erlangen, Germany) for assessment of primary Sjögren syndrome. METHODS Fifty-four patients with primary Sjögren syndrome, 35 patients without primary Sjögren syndrome (patients with dry mouth and dry eye symptoms), and 52 healthy control volunteers were included in this study. Patients with primary Sjögren syndrome were classified as early or advanced stage by labial gland biopsies. All participants underwent B-mode sonography, on which the salivary glands (parotid and submandibular) were identified and VTQ measurements of shear wave velocity (SWV) were obtained. The diagnostic performance of SWV was evaluated by sensitivity and specificity at the optimum cutoff point and the area under the receiver operating characteristic curve. RESULTS For submandibular glands, the mean SWV ± SD values were 2.25 ± 0.34 m/s in patients with early-stage primary Sjögren, 1.84 ± 0.20 m/s in patients without primary Sjögren syndrome, and 1.82 ± 0.27 m/s in healthy controls (P< .001). With cutoff values of 2.15 and 2.10 m/s to separate patients with early-stage primary Sjögren syndrome from those without Sjögren syndrome and healthy controls, the sensitivity and specificity were 77.1% and 85.4% and 79.2% and 83.9%, respectively. For parotid glands, the SWV values were 2.78 ± 0.82 m/s in patients with early-stage primary Sjögren syndrome, 1.93 ± 0.33 m/s, in patients without primary Sjögren syndrome, and 1.85 ± 0.31 m/s in healthy controls (P < .001). With cutoff values of 2.18 and 2.10 m/s to separate patients with early-stage primary Sjögren syndrome from those without Sjögren syndrome and healthy controls, the sensitivity and specificity were 89.3 % and 75.3% and 91.4% and 80.0%. CONCLUSIONS The VTQ technique might be a useful noninvasive strategy for assessment of salivary glands in the early stage of primary Sjögren syndrome.
Collapse
Affiliation(s)
- Shaoqi Chen
- Department of Ultrasound, First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Yukai Wang
- Department of Rheumatism, Central Hospital of Shantou, Shantou, China
| | - Shaoxing Chen
- Department of Community Monitoring, First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Qiulin Wu
- Guangdong Province Key Laboratory of Medical Molecular Imaging, Shantou University, Shantou, China
| | - Shigao Chen
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota USA
| |
Collapse
|
31
|
Hofauer B, Mansour N, Heiser C, Wirth M, Straßen U, Loeffelbein D, Bas M, Knopf A. Reproducibility of Acoustic Radiation Force Impulse Imaging in Thyroid and Salivary Glands with Experienced and Inexperienced Examiners. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2545-2552. [PMID: 27475926 DOI: 10.1016/j.ultrasmedbio.2016.06.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2016] [Revised: 06/07/2016] [Accepted: 06/10/2016] [Indexed: 06/06/2023]
Abstract
Acoustic radiation force impulse (ARFI) imaging enables the sonographic measurement of tissue stiffness. The aim of this study was to evaluate if experience in ARFI imaging influences the reproducibility of ARFI imaging of the head and neck. Three experienced sonographers and three inexperienced sonographers performed ARFI imaging of thyroid, submandibular and parotid glands in 10 healthy volunteers. The examination was repeated after 2 wk. Ten single ARFI measurements were done in every gland. Inter-rater and intra-rater reliability was analyzed using the intra-class correlation coefficient (ICC). Moderate agreement was observed between experienced and inexperienced examiners (ICC = 0.46). In salivary glands, agreement was fair between the groups (ICC = 0.33), whereas in separate evaluations, inter-rater reliability in the submandibular glands was moderate (ICC = 0.52), and that in the parotid glands, only poor (ICC = 0.09). For ARFI imaging of the thyroid gland, there was moderate agreement between the groups (ICC = 0.50). The intra-rater reliability for the salivary and thyroid glands together and separately was strong in both groups. ARFI imaging of the thyroid and salivary glands did exhibit good reproducibility. ARFI imaging of the thyroid gland reached the highest levels of inter- and intra-observer agreement in both groups. ARFI imaging in salivary glands is only reproducible with experienced examiners.
Collapse
Affiliation(s)
- Benedikt Hofauer
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
| | - Naglaa Mansour
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany
| | - Clemens Heiser
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany
| | - Markus Wirth
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany
| | - Ulrich Straßen
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany
| | - Denys Loeffelbein
- Cranio-Maxillo-Facial Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany
| | - Murat Bas
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany
| | - Andreas Knopf
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany
| |
Collapse
|
32
|
Cornec D, Jousse-Joulin S, Costa S, Marhadour T, Marcorelles P, Berthelot JM, Hachulla E, Hatron PY, Goeb V, Vittecoq O, Nowak E, Pers JO, Devauchelle-Pensec V, Saraux A. High-Grade Salivary-Gland Involvement, Assessed by Histology or Ultrasonography, Is Associated with a Poor Response to a Single Rituximab Course in Primary Sjögren's Syndrome: Data from the TEARS Randomized Trial. PLoS One 2016; 11:e0162787. [PMID: 27662653 PMCID: PMC5035078 DOI: 10.1371/journal.pone.0162787] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 08/29/2016] [Indexed: 01/11/2023] Open
Abstract
Purpose To determine whether the severity of salivary-gland involvement, assessed using salivary gland ultrasonography [SGUS], histological focus score, or the unstimulated whole salivary flow [UWSF], was associated with the response to rituximab in patients with primary Sjögren’s syndrome [pSS]. Materials and Methods Among the 120 patients with pSS enrolled in the randomised TEARS trial of rituximab versus placebo, 35 underwent either centralised minor salivary-gland biopsy or SGUS at inclusion. The echostructure of each parotid and submandibular gland was graded on a scale of 0 to 4. Histologic minor salivary gland involvement was assessed by the focus score. Among rituximab-treated patients with available data (n = 14), half met the Sjögren’s Syndrome Responder Index [SSRI]-30 definition of a response at week 24. Results The SGUS score correlated positively to the focus score [r = 0.61] and negatively to the UWSF [r = -0.68]. The focus score was not correlated to the UWSF. The median total SGUS grade at inclusion was 9 [6-11] in responders versus 16 [11-16] in non-responders [p = 0.04]. The proportion of SSRI-30 responders was 0% among patients with SGUS grade 4 and 88% among those with SGUS grade ≤3. Low baseline SGUS scores were associated with sicca-related outcomes improvement, but not with fatigue or biological improvement. Median baseline focus score was 0.3 [0.0–1.3] in the responders versus 4.0 [2.7–5.3] in the non-responders [p = 0.02]. Baseline UWSF was not associated with the response rate. Conclusion In patients with pSS, the highest SGUS grade or a high histological focus score is associated with absence of a response to a single rituximab course after 6 months. Further studies, including more patients and different treatment strategies, are required to confirm the clinical utility of these potential biomarkers in pSS.
Collapse
Affiliation(s)
- Divi Cornec
- Service de Rhumatologie, Hôpital de la Cavale Blanche, CHRU Brest, Boulevard Tanguy Prigent, 29609 Brest, France
- EA2216, INSERM ESPRI, ERI29, Laboratoire d’Immunothérapies et Pathologies lymphocytaires B, Université de Brest, and Labex "IGO", Brest, France
| | - Sandrine Jousse-Joulin
- Service de Rhumatologie, Hôpital de la Cavale Blanche, CHRU Brest, Boulevard Tanguy Prigent, 29609 Brest, France
- EA2216, INSERM ESPRI, ERI29, Laboratoire d’Immunothérapies et Pathologies lymphocytaires B, Université de Brest, and Labex "IGO", Brest, France
| | - Sebastian Costa
- Laboratoire d’Anatomie Pathologique et Cytologie, Hôpital Morvan, CHRU Brest, Avenue Foch, 29609 Brest, France
| | - Thierry Marhadour
- Service de Rhumatologie, Hôpital de la Cavale Blanche, CHRU Brest, Boulevard Tanguy Prigent, 29609 Brest, France
| | - Pascale Marcorelles
- Laboratoire d’Anatomie Pathologique et Cytologie, Hôpital Morvan, CHRU Brest, Avenue Foch, 29609 Brest, France
| | | | - Eric Hachulla
- Service de Médecine Interne, Claude Huriez Hospital, Université Lille Nord-de-France, 59037 Lille Cedex, France
| | - Pierre-Yves Hatron
- Service de Médecine Interne, Claude Huriez Hospital, Université Lille Nord-de-France, 59037 Lille Cedex, France
| | - Vincent Goeb
- Service de Rhumatologie, CHRU de Rouen, 76230 Bois-Guillaume, France
| | - Olivier Vittecoq
- Service de Rhumatologie, CHRU de Rouen, 76230 Bois-Guillaume, France
| | | | - Jacques-Olivier Pers
- EA2216, INSERM ESPRI, ERI29, Laboratoire d’Immunothérapies et Pathologies lymphocytaires B, Université de Brest, and Labex "IGO", Brest, France
| | - Valérie Devauchelle-Pensec
- Service de Rhumatologie, Hôpital de la Cavale Blanche, CHRU Brest, Boulevard Tanguy Prigent, 29609 Brest, France
- EA2216, INSERM ESPRI, ERI29, Laboratoire d’Immunothérapies et Pathologies lymphocytaires B, Université de Brest, and Labex "IGO", Brest, France
| | - Alain Saraux
- Service de Rhumatologie, Hôpital de la Cavale Blanche, CHRU Brest, Boulevard Tanguy Prigent, 29609 Brest, France
- EA2216, INSERM ESPRI, ERI29, Laboratoire d’Immunothérapies et Pathologies lymphocytaires B, Université de Brest, and Labex "IGO", Brest, France
- * E-mail:
| |
Collapse
|
33
|
Hofauer B, Mansour N, Heiser C, Gahleitner C, Thuermel K, Bas M, Knopf A. Sonoelastographic Modalities in the Evaluation of Salivary Gland Characteristics in Sjögren's Syndrome. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2130-2139. [PMID: 27207020 DOI: 10.1016/j.ultrasmedbio.2016.04.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 02/23/2016] [Accepted: 04/11/2016] [Indexed: 06/05/2023]
Abstract
The purpose of this study was to investigate salivary tissue assessment with various sonoelastographic modalities (real-time tissue elastography, Virtual Touch imaging and quantification) in patients with Sjögren's syndrome as compared with an appropriate control group. The sonoelastographic modalities were evaluated in 50 patients with primary Sjögren's syndrome (pSS). Patients underwent high-resolution ultrasonography of the submandibular and parotid glands. Results of B-mode, real-time tissue elastography, Virtual Touch imaging-each graded with the appropriate scoring system-and Virtual Touch quantification were compared with those for 50 patients with sicca symptoms who did not fulfill the American-European consensus group criteria. In B-mode, 34 of 50 parotid glands in patients with pSS and 8 of 50 in the control group had abnormal findings (p < 0.001). Compared with 9 of 50 control patients, 38 of 50 patients with pSS had abnormal findings in submandibular gland B-mode (p < 0.001). With real-time tissue elastography, there was a trend toward higher scores for parotid glands in the pSS group (p = 0.238), whereas scores for submandibular glands in the control group were higher (p = 0.107). Virtual Touch imaging did not indicate any difference (p = 0.647 and p = 0.658). In Virtual Touch quantification, values for parotid (mean: 2.99 m/s) and submandibular glands (mean: 2.54 m/s) in the pSS group were higher than those for parotid (mean: 2.16 m/s) and submandibular (mean: 2.04 m/s) glands in the control group (p < 0.001 and p = 0.008). Glandular stiffness, measured by Virtual Touch quantification, was significantly higher in patients with Sjögreńs syndrome than in patients with sicca symptoms.
Collapse
Affiliation(s)
- Benedikt Hofauer
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University, Munich, Germany.
| | - Naglaa Mansour
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University, Munich, Germany
| | - Clemens Heiser
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University, Munich, Germany
| | - Constanze Gahleitner
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University, Munich, Germany
| | - Klaus Thuermel
- Rheumatology, II. Medizinische Department, Klinikum rechts der Isar, Technical University, Munich, Germany
| | - Murat Bas
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University, Munich, Germany
| | - Andreas Knopf
- Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University, Munich, Germany
| |
Collapse
|
34
|
Effect of liposomal local therapy on salivary glands in acoustic radiation force impulse imaging in Sjögren's syndrome. Clin Rheumatol 2016; 35:2597-601. [PMID: 27572326 DOI: 10.1007/s10067-016-3395-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2016] [Revised: 08/20/2016] [Accepted: 08/22/2016] [Indexed: 12/15/2022]
Abstract
The purpose of this study was to evaluate the utility of acoustic radiation force impulse (ARFI) imaging as a monitoring tool for the effect of a liposomal local therapy in patients with dry mouth symptoms due to primary Sjögren's syndrome (pSS). Fifty patients with pSS, diagnosed according to the American-European Consensus Group (AECG) criteria, were included. Clinical data were collected, and sonographic examination including ARFI imaging of the parotid and submandibular glands was performed. Subjective symptoms were evaluated via visual analogue scales (VAS), and the unstimulated whole salivary flow was measured. After a two-month period of liposomal local therapy, sonographic examination was repeated and both subjective and objective symptoms were re-evaluated. Before local treatment, the mean ARFI value of parotid glands was 2.96 m/s (SD 0.97). Mean ARFI value of the submandibular glands was 2.09 m/s (SD 0.71). After the two-month treatment period, a significant decline of ARFI values in the parotid glands to a value of 2.34 m/s (SD 0.70, p < 0.001) could be observed. The submandibular glands did not show any significant change. Further, a significant reduction of the subjective sensation of dry mouth symptoms could be observed (p = 0.0001). With the application of ARFI imaging, a decline in parotid gland stiffness could be observed in patients with primary Sjögren's Syndrome accompanied by a significant improvement of the subjective sensation of dry mouth symptoms. The seromucous submandibular glands did not show any changes compared to the serous parotid glands.
Collapse
|
35
|
Li C, Zhang C, Li N, Li J. Compression Real-time Elastography for Evaluation of Salivary Gland Lesions: A Meta-analysis. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:999-1007. [PMID: 27072157 DOI: 10.7863/ultra.15.08043] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Accepted: 12/03/2015] [Indexed: 06/05/2023]
Abstract
OBJECTIVES To evaluate the performance of compression real-time elastography for differentiation between benign and malignant salivary gland lesions. METHODS A systematic literature database search was conducted. Pooled sensitivity, specificity, positive likelihood ratio (LR+), and negative likelihood ratio (LR-) values for real-time elastography were analyzed. Summary receiver operating characteristic (ROC) curves were also constructed. Heterogeneity was evaluated by χ(2) and I(2) tests. I(2) > 50% or P < .05 indicated heterogeneity, and then a random-effects model was applied. A Deek funnel plot was used to assess publication bias. Fagan plot analysis was performed to evaluate the clinical utility of real-time elastography. When heterogeneity was found, subgroup analyses were used to explore the sources of heterogeneity. A sensitivity analysis was conducted by omitting 1 study at a time and examining the influence of each individual study on the overall results. RESULTS Nine articles with 581 lesions were included. The pooled sensitivity and specificity of real-time elastography for differentiation between benign and malignant lesions were 76% (95% confidence interval [CI], 65%-85%; 95% prediction interval [PI], 29%-95%) and 73% (95% CI, 62%-81%; 95% PI, 24%-96%), respectively. The LR+ and LR- were 2.81 (95% CI, 1.79-4.39; 95% PI, 0.65-12.16) and 0.33 (95% CI, 0.20-0.55; 95% PI, 0.07-1.69). The area under the ROC curve was 0.81 (95% CI, 0.77-0.84). No publication bias was detected, according to the Deek funnel plot (P = .51). The Fagan plot showed that when pretest probabilities were 25%, 50%, and 75%, positive posttest probabilities were 48%, 74%, and 89%, and negative probabilities were 10%, 25%, and 50%. CONCLUSIONS Real-time elastography is a novel supplementary adjunct to conventional sonography for evaluation of salivary gland lesions. However, its overall accuracy is less promising, and biopsy may still be necessary in routine clinical practice.
Collapse
Affiliation(s)
- Changtian Li
- Department of Ultrasound, Southern Building, Chinese PLA General Hospital, Beijing, China
| | - Changsheng Zhang
- Department of Anesthesia and Operation Center, Chinese PLA General Hospital, Beijing, China
| | - Nan Li
- Department of Ultrasound, Southern Building, Chinese PLA General Hospital, Beijing, China
| | - Junlai Li
- Department of Ultrasound, Southern Building, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
36
|
Chen S, Wang Y, Zhang G, Chen S. Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study. BIOMED RESEARCH INTERNATIONAL 2016; 2016:2793898. [PMID: 28078285 PMCID: PMC5203879 DOI: 10.1155/2016/2793898] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Accepted: 11/23/2016] [Indexed: 02/05/2023]
Abstract
A total of 136 subjects (51 SS patients, 35 sicca syndrome patients without SS, and 50 healthy volunteers) were enrolled in this study. The mean SWV value for salivary glands of SS patients was statistically higher than that of controls (2.81 ± 0.66 m/s versus 1.85 ± 0.28 m/s for parotid glands and 2.29 ± 0.34 m/s versus 1.82 ± 0.25 m/s for submandibular glands, resp.). Combining SWV values of parotid and submandibular glands gives a sensitivity of 88.2% (95% CI: 76.1-95.6%) and specificity of 96.0% (95% CI: 86.3-99.5%) at the cutoff point of 2.19 m/s, with an AUROC of 0.954 (95% CI: 0.893-0.986). In addition, combining SGUS score and SWV value yields a sensitivity of 98.0% (95% CI: 89.6-100%), specificity of 90.0% (95% CI: 78.2-96.7%), and AUROC of 0.962 (95% CI: 0.904-0.990). Classification tree considering the sequential use of SGUS score and SWV value achieved 92.1% accuracy for diagnosis of SS. Similarly, the ROC curve of combined SGUS scores and SWV values yields an AUROC of 0.954 (95% CI: 0.885-0.987), sensitivity of 97.1% (95% CI: 85.1-99.9%), and specificity of 92.2% (95% CI: 81.1-97.8%) for separating sicca syndrome patients (without SS) from SS patients. Combining SGUS and VTQ provides a promising tool for diagnosis of SS.
Collapse
Affiliation(s)
- Shaoqi Chen
- Department of Ultrasound, The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong, China
| | - Yukai Wang
- Department of Rheumatology, Shantou Central Hospital, Shantou, Guangdong, China
- *Yukai Wang: and
| | - Guohong Zhang
- Department of Pathology, Shantou University Medical College, Shantou, Guangdong, China
- *Guohong Zhang:
| | - Shigao Chen
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, MN, USA
| |
Collapse
|
37
|
Beckman KA, Luchs J, Milner MS. Making the diagnosis of Sjögren's syndrome in patients with dry eye. Clin Ophthalmol 2015; 10:43-53. [PMID: 26766898 PMCID: PMC4699514 DOI: 10.2147/opth.s80043] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Sjögren’s syndrome (SS) is a chronic and progressive systemic autoimmune disease that often presents initially with symptoms of dry eye and dry mouth. Symptoms are often nonspecific and develop gradually, making diagnosis difficult. Patients with dry eye complaints warrant a step-wise evaluation for possible SS. Initial evaluation requires establishment of a dry eye diagnosis using a combination of patient questionnaires and objective ocular tests, including inflammatory biomarker testing. Additional work-up using the Schirmer test and tear film break-up time can differentiate between aqueous-deficient dry eye (ADDE) and evaporative dry eye. The presence of ADDE should trigger further work-up to differentiate between SS-ADDE and non-SS-ADDE. There are numerous non-ocular manifestations of SS, and monitoring for SS-related comorbid findings can aid in diagnosis, ideally in collaboration with a rheumatologist. The clinical work-up of SS can involve a variety of tests, including tear function tests, serological tests for autoantibody biomarkers, minor salivary gland and lacrimal gland biopsies. Examination of classic SS biomarkers (SS-A/Ro, SS-B/La, antinuclear antibody, and rheumatoid factor) is a convenient and non-invasive way of evaluating patients for the presence of SS, even years prior to confirmed diagnosis, although not all SS patients will test positive, particularly those with early disease. Recently, newer biomarkers have been identified, including autoantibodies to salivary gland protein-1, parotid secretory protein, and carbonic anhydrase VI, and may allow for earlier diagnosis of SS. A diagnostic test kit is commercially available (Sjö®), incorporating these new biomarkers along with the classic autoantibodies. This advanced test has been shown to identify SS patients who previously tested negative against traditional biomarkers only. All patients with clinically significant ADDE should be considered for serological assessment for SS, given the availability of new serological diagnostic tests and the potentially serious consequences of missing the diagnosis.
Collapse
Affiliation(s)
- Kenneth A Beckman
- Comprehensive EyeCare of Central Ohio, Westerville, OH, USA; The Ohio State University, Columbus, OH, USA
| | - Jodi Luchs
- Hofstra University School of Medicine, Hempstead, NY, USA; South Shore Eye Care, Wantagh, NY, USA
| | - Mark S Milner
- The Eye Center of Southern Connecticut, PC, Hamden, CT, USA; Yale University School of Medicine, New Haven, CT, USA
| |
Collapse
|
38
|
[Clinical usefulness of salivary gland ultrasonography in Sjögren's syndrome: Where are we now?]. Rev Med Interne 2015; 37:186-94. [PMID: 26608250 DOI: 10.1016/j.revmed.2015.10.341] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Accepted: 10/19/2015] [Indexed: 12/18/2022]
Abstract
Salivary gland ultrasonography is a simple, noninvasive and inexpensive procedure, which provides valuable information for the diagnosis of primary Sjögren's syndrome (pSS). The main sonographic characteristic of the major salivary glands (parotid and submandibular) in pSS patients is the heterogeneity of the parenchyma, with the appearance of hypoechoic areas. Numerous studies published over the past 20 years report a sensitivity of 70% and a specificity of more than 90% for the diagnosis of pSS. Before the widespread use of this procedure in daily practice and its integration into classification criteria of the disease, it has yet to be validated in terms of reproducibility and a consensus score should be established. This work is being conducted by an international group of experts. Other ultrasound techniques such as elastography could also be of interest to objectively quantify changes in the glandular tissue that occur during the disease.
Collapse
|