1
|
Frush DP, Vassileva J, Brambilla M, Mahesh M, Rehani M, Samei E, Applegate K, Bourland J, Ciraj-Bjenlac O, Dahlstrom D, Gershan V, Gilligan P, Godthelp B, Hjemly H, Kainberger F, Mikhail-Lette M, Holmberg O, Paez D, Schrandt S, Valentin A, Van Deventer T, Wakeford R. Recurrent medical imaging exposures for the care of patients: one way forward. Eur Radiol 2024; 34:6475-6487. [PMID: 38592419 DOI: 10.1007/s00330-024-10659-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/17/2023] [Accepted: 01/23/2024] [Indexed: 04/10/2024]
Abstract
Medical imaging is both valuable and essential in the care of patients. Much of this imaging depends on ionizing radiation with attendant responsibilities for judicious use when performing an examination. This responsibility applies in settings of both individual as well as multiple (recurrent) imaging with associated repeated radiation exposures. In addressing the roles and responsibilities of the medical communities in the paradigm of recurrent imaging, both the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) have issued position statements, each affirmed by other organizations. The apparent difference in focus and approach has resulted in a lack of clarity and continued debate. Aiming towards a coherent approach in dealing with radiation exposure in recurrent imaging, the IAEA convened a panel of experts, the purpose of which was to identify common ground and reconcile divergent perspectives. The effort has led to clarifying recommendations for radiation exposure aspects of recurrent imaging, including the relevance of patient agency and the provider-patient covenant in clinical decision-making. CLINICAL RELEVANCE STATEMENT: An increasing awareness, generating some lack of clarity and divergence in perspectives, with patients receiving relatively high radiation doses (e.g., ≥ 100 mSv) from recurrent imaging warrants a multi-stakeholder accord for the benefit of patients, providers, and the imaging community. KEY POINTS: • Recurrent medical imaging can result in an accumulation of exposures which exceeds 100 milli Sieverts. • Professional organizations have different perspectives on roles and responsibilities for recurrent imaging. • An expert panel reconciles differing perspectives for addressing radiation exposure from recurrent medical imaging.
Collapse
Affiliation(s)
- Donald Paul Frush
- Department of Radiology, Duke University Medical Center, Durham, NC, 27705, USA.
| | - Jenia Vassileva
- Radiation Protection of Patients Unit, International Atomic Energy Agency, Vienna, Austria
| | - Marco Brambilla
- Department of Medical Physics, University Hospital of Novara, Novara, Italy
| | - Mahadevappa Mahesh
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, USA
| | - Madan Rehani
- Department of Radiology, Massachusetts General Hospital, Boston, USA
| | - Ehsan Samei
- Department of Radiology, Duke University Medical Center, Durham, NC, 27705, USA
| | | | - John Bourland
- Department of Radiation Oncology, Wake Forest University School of Medicine, Winston-Salem, NC, USA
| | | | | | - Vesna Gershan
- Radiation Protection of Patients Unit, International Atomic Energy Agency, Vienna, Austria
| | - Paddy Gilligan
- Mater Misericordiae University Hospital, Dublin, Ireland
| | - Barbara Godthelp
- Authority for Nuclear Safety and Radiation Protection, The Hague, The Netherlands
| | - Hakon Hjemly
- International Society of Radiographers and Radiological Technologists, London, UK
| | - Franz Kainberger
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | | | - Ola Holmberg
- Radiation Protection of Patients Unit, International Atomic Energy Agency, Vienna, Austria
| | - Diana Paez
- Division of Human Health, International Atomic Energy Agency, Vienna, Austria
| | - Suz Schrandt
- ExPPect, Founder & CEO, and Patients for Patient Safety US, Champion (Affiliate, WHO PFPS Network), Arlington, VA, USA
| | - Andreas Valentin
- Department of Internal Medicine With Cardiology & Intensive Care Medicine Clinic Donaustadt Vienna Health Care Group, Vienna, Austria
| | | | - Richard Wakeford
- Centre for Occupational and Environmental Health, The University of Manchester, Manchester, UK
| |
Collapse
|
2
|
Naimi S, Tetteh MA, Ashraf H, Johansen S. Evaluation of an in-use chest CT protocol in lung cancer screening - A single institutional study. Acta Radiol Open 2024; 13:20584601241256005. [PMID: 39044837 PMCID: PMC11265249 DOI: 10.1177/20584601241256005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 05/02/2024] [Indexed: 07/25/2024] Open
Abstract
Background Lung cancer is the most common cause of cancer-related death worldwide and therefore there has been a growing demand for low-dose computed tomography (LDCT) protocols. Purpose To investigate and evaluate the dose and image quality of patients undergoing lung cancer screening (LCS) using LDCT in Norway. Materials and Methods Retrospective dosimetry data, volumetric CT dose index (CTDIvol) and dose-length product (DLP), from 70 average-size and 70 large-size patients who underwent LDCT scan for LCS were included in the survey. Effective dose and size-specific dose were calculated for each examination and were compared with the American Association of Physicists in Medicine (AAPM) requirement. For a quantitative image quality analysis, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were determined for different regions in the chest with two iterative reconstruction techniques, iDose and Iterative Model Reconstruction. Differences in dose and image quality between average-size and large-size patients were evaluated by Independent sample t test, and Wilcoxon signed rank test within the same patient group. Results The independent sample t test revealed significant differences (p < .05) in dose values between average-size and large-size patients. Mean CTDIvol and DLP for average-size patients were 2.8 mGy and 115 mGy.cm, respectively, with appropriate increment for the large-size patients. Image quality (image noise, SNR, and CNR) did not significantly differ between patient groups when images were reconstructed with a model based iterative reconstruction algorithm. Conclusion The screening protocol assessed in this study resulted in CTDIvol values that were compliant with AAPM recommendation. No significant differences in objective image quality were found between patient groups.
Collapse
Affiliation(s)
- Salma Naimi
- Health faculty, Oslo Metropolitan University, Oslo, Norway
| | - Mercy Afadzi Tetteh
- Department of Diagnostic Imaging, Akershus University Hospital, Lørenskog, Norway
| | - Haseem Ashraf
- Department of Diagnostic Imaging, Akershus University Hospital, Lørenskog, Norway
- Division of Medicine and Laboratory Sciences, University of Oslo, Oslo, Norway
| | - Safora Johansen
- Health faculty, Oslo Metropolitan University, Oslo, Norway
- Department of Cancer Treatment, Oslo University Hospital, Oslo, Norway
- Health and Social Sciences, Cluster, Singapore Institution of Technology, Singaporee
| |
Collapse
|
3
|
Oshima Y, Ohno Y, Takenaka D, Ito Y, Kimata H, Fujii K, Akino N, Hamabuchi N, Matsuyama T, Nagata H, Ueda T, Ikeda H, Ozawa Y, Yoshikawa T, Toyama H. Capability for dose reduction while maintaining nodule detection: Comparison of silver and copper X-ray spectrum modulation filters for chest CT using a phantom study with different reconstruction methods. Eur J Radiol 2023; 166:110969. [PMID: 37454556 DOI: 10.1016/j.ejrad.2023.110969] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 07/03/2023] [Accepted: 07/10/2023] [Indexed: 07/18/2023]
Abstract
PURPOSE To compare the capability of CTs obtained with a silver or copper x-ray beam spectral modulation filter (Ag filter and Cu filter) and reconstructed with FBP, hybrid-type IR and deep learning reconstruction (DLR) for radiation dose reduction for lung nodule detection using a chest phantom study. MATERIALS AND METHODS A chest CT phantom was scanned with a 320-detector row CT with Ag filter at 0.6, 1.6 and 2.5 mGy and Cu filters at 0.6, 1.6, 2.5 and 9.6 mGy, and reconstructed with the aforementioned methods. To compare image quality of all the CT data, SNRs and CNRs for any nodule were calculated for all protocols. To compare nodule detection capability among all protocols, the probability of detection of any nodule was assessed with a 5-point visual scoring system. Then, ROC analyses were performed to compare nodule detection capability of Ag and Cu filters for each radiation dose data with the same method and of the three methods for any radiation dose data and obtained with either filter. RESULTS At any of the doses, SNR, CNR and area under the curve for the Ag filter were significantly higher or larger than those for the Cu filter (p < 0.05). Moreover, with DLR, those values were significantly higher or larger than all the others for CTs obtained with any of the radiation doses and either filter (p < 0.05). CONCLUSION The Ag filter and DLR can significantly improve image quality and nodule detection capability compared with the Cu filter and other reconstruction methods at each of radiation doses used.
Collapse
Affiliation(s)
- Yuka Oshima
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Yoshiharu Ohno
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan; Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan.
| | - Daisuke Takenaka
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan; Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi, Hyogo, Japan
| | - Yuya Ito
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Hirona Kimata
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Kenji Fujii
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Naruomi Akino
- Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Nayu Hamabuchi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Takahiro Matsuyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Hiroyuki Nagata
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Hirotaka Ikeda
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Yoshiyuki Ozawa
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| | - Takeshi Yoshikawa
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan; Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake, Aichi, Japan
| |
Collapse
|
4
|
Cancer risk in healthy patients who underwent chest tomography comparing three different technologies. Appl Radiat Isot 2023; 193:110625. [PMID: 36680979 DOI: 10.1016/j.apradiso.2022.110625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 12/15/2022] [Accepted: 12/20/2022] [Indexed: 12/30/2022]
Abstract
This research aimed to estimate the risk of cancer associated with patients without previous disease undergoing chest tomography. Siemens CT scanners have 6, 64, and 128 detectors. The Biologic Effects of Ionizing Radiation Reports - BEIR VII methodology was used. The study presented a sample of 64 patients aged between 18 and 80 years, in the city of Belo Horizonte, Minas Gerais - Brazil. The IMPACT CT software and CalDose X CT Online were used to calculate the absorbed and equivalent dose from the Volumetric Computed Tomography Dose Index - CTDIvol (mGy) and Dose Length Product - DLP values provided by the equipment. CT-Expo Software was also used to estimate Specific Dose Estimates (SSDEs) values. The CTDvol results for the MG1, MG,2 and MG3 Diagnostic Centers in mGy were respectively 4.369 ± 1.352, 6.99 4 ± 1.53,3 and 9.984 ± 2.282 and the SSDE values were 3.800, 6.40,0 and 9,.500. The values for the equivalent dose, at the MG2 Diagnostic Center, by IMPACT CT, in (mSv) for the breasts, esophagus, heart, thyroid, lung and thymus were respectively 3.9, 5.7, 4.7, 1.0, 4.8 and 5.7. The CalDose Software, for the same equipment and the same organs, in mSv, estimated the values 7.4, 9.4, 11.1, 5.3, 10.8 and 11.3 for women and 7.1, 9.3, 11.0, 5.3, 10.2 and 10.9 for men. The estimated risk of cancer decreased according to the patient's age, but with a higher incidence for females. The use of each software must be carefully analyzed to avoid undue values due to the particularities of each one. The results also showed that the risk of developing cancer due to radiation decreases with patient age and is higher in females.
Collapse
|
5
|
Pozzessere C, von Garnier C, Beigelman-Aubry C. Radiation Exposure to Low-Dose Computed Tomography for Lung Cancer Screening: Should We Be Concerned? Tomography 2023; 9:166-177. [PMID: 36828367 PMCID: PMC9964027 DOI: 10.3390/tomography9010015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/13/2023] [Accepted: 01/17/2023] [Indexed: 01/26/2023] Open
Abstract
Lung cancer screening (LCS) programs through low-dose Computed Tomography (LDCT) are being implemented in several countries worldwide. Radiation exposure of healthy individuals due to prolonged CT screening rounds and, eventually, the additional examinations required in case of suspicious findings may represent a concern, thus eventually reducing the participation in an LCS program. Therefore, the present review aims to assess the potential radiation risk from LDCT in this setting, providing estimates of cumulative dose and radiation-related risk in LCS in order to improve awareness for an informed and complete attendance to the program. After summarizing the results of the international trials on LCS to introduce the benefits coming from the implementation of a dedicated program, the screening-related and participant-related factors determining the radiation risk will be introduced and their burden assessed. Finally, future directions for a personalized screening program as well as technical improvements to reduce the delivered dose will be presented.
Collapse
Affiliation(s)
- Chiara Pozzessere
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne (UNIL), 1011 Lausanne, Switzerland
- Correspondence:
| | - Christophe von Garnier
- Faculty of Biology and Medicine, University of Lausanne (UNIL), 1011 Lausanne, Switzerland
- Division of Pulmonology, Department of Medicine, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland
| | - Catherine Beigelman-Aubry
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne (UNIL), 1011 Lausanne, Switzerland
| |
Collapse
|
6
|
Ma G, Yang D, Li Y, Li M, Li J, Fu J, Peng Z. Combined measurement of circulating tumor cell counts and serum tumor marker levels enhances the screening efficiency for malignant versus benign pulmonary nodules. Thorac Cancer 2022; 13:3393-3401. [PMID: 36284506 PMCID: PMC9715841 DOI: 10.1111/1759-7714.14702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 10/03/2022] [Accepted: 10/06/2022] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND The high false-positive rate for pulmonary nodules (PNs) from using low-dose computed tomography (LDCT) screening can lead to overuse of invasive procedures, overtreatment, and patient anxiety. Therefore, it is very important to develop new diagnostic methods. METHODS A negative enrichment-fluorescence in situ hybridization (NE-FISH) approach was used to detect circulating tumor cells (CTCs) in patients with PNs. We evaluated whether or not the combination of CTC counts with serum tumor marker levels (CEA, CA 125, CYFRA 21-1, SCC) could improve the diagnostic ability for distinguishing patients with malignant pulmonary nodules (MPNs) from those with benign pulmonary nodules (BPNs). Moreover, the potential clinical application of this combination for the diagnosis of solitary pulmonary nodules (SPNs) with a diameter ≤2 cm was also investigated. RESULTS The combination of CTC counts and tumor marker levels had a sensitivity of 80.12% and the area under the receiver operating characteristics curve (AUCROC ) of 0.853 (95% confidence interval [CI]: 0.800-0.897, p < 0.001) for the differential diagnosis of PNs. For early cancer stages, the sensitivity was 75.38% (AUCROC = 0.780, 95% CI: 0.713-0.838, p < 0.001). In addition, for SPNs within 2 cm the combination of CTC counts and tumor marker levels was still the most valuable diagnostic tool with a sensitivity of 78.95% and AUCROC of 0.888. CONCLUSION The combination of CTC counts and serum tumor marker levels is helpful for improving the diagnosis of PNs, especially in the early stages of cancer and for SPNs within 2 cm.
Collapse
Affiliation(s)
- Guojun Ma
- Department of Thoracic Surgery, Shandong Provincial Hospital, Cheeloo College of MedicineShandong UniversityJinanChina,Department of Thoracic SurgeryLiaocheng People's HospitalLiaochengChina
| | - Dawei Yang
- Zhong Yuan Academy of Biological MedicineLiaocheng People's HospitalLiaochengChina
| | - Yang Li
- Zhong Yuan Academy of Biological MedicineLiaocheng People's HospitalLiaochengChina
| | - Meng Li
- Department of Thoracic Surgery, Shandong Provincial Hospital, Cheeloo College of MedicineShandong UniversityJinanChina
| | - Jingtao Li
- Department of Thoracic SurgeryLiaocheng People's HospitalLiaochengChina
| | - Jianhua Fu
- Department of Thoracic SurgeryLiaocheng People's HospitalLiaochengChina
| | - Zhongmin Peng
- Department of Thoracic Surgery, Shandong Provincial Hospital, Cheeloo College of MedicineShandong UniversityJinanChina
| |
Collapse
|
7
|
Single CT Appointment for Double Lung and Colorectal Cancer Screening: Is the Time Ripe? Diagnostics (Basel) 2022; 12:diagnostics12102326. [PMID: 36292015 PMCID: PMC9601268 DOI: 10.3390/diagnostics12102326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Revised: 09/15/2022] [Accepted: 09/21/2022] [Indexed: 12/24/2022] Open
Abstract
Annual screening of lung cancer (LC) with chest low-dose computed tomography (CT) and screening of colorectal cancer (CRC) with CT colonography every 5 years are recommended by the United States Prevention Service Task Force. We review epidemiological and pathological data on LC and CRC, and the features of screening chest low-dose CT and CT colonography comprising execution, reading, radiation exposure and harm, and the cost effectiveness of the two CT screening interventions. The possibility of combining chest low-dose CT and CT colonography examinations for double LC and CRC screening in a single CT appointment is then addressed. We demonstrate how this approach appears feasible and is already reasonable as an opportunistic screening intervention in 50–75-year-old subjects with smoking history and average CRC risk. In addition to the crucial role Computer Assisted Diagnosis systems play in decreasing the test reading times and the need to educate radiologists in screening chest LDCT and CT colonography, in view of a single CT appointment for double screening, the following uncertainties need to be solved: (1) the schedule of the screening CT; (2) the effectiveness of iterative reconstruction and deep learning algorithms affording an ultra-low-dose CT acquisition technique and (3) management of incidental findings. Resolving these issues will imply new cost-effectiveness analyses for LC screening with chest low dose CT and for CRC screening with CT colonography and, especially, for the double LC and CRC screening with a single-appointment CT.
Collapse
|
8
|
Kowada A. Cost-effectiveness and health impact of lung cancer screening with low-dose computed tomography for never smokers in Japan and the United States: a modelling study. BMC Pulm Med 2022; 22:19. [PMID: 34996423 PMCID: PMC8742389 DOI: 10.1186/s12890-021-01805-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 12/16/2021] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Never smokers in Asia have a higher incidence of lung cancer than in Europe and North America. We aimed to assess the cost-effectiveness of lung cancer screening with low-dose computed tomography (LDCT) for never smokers in Japan and the United States. METHODS We developed a state-transition model for three strategies: LDCT, chest X-ray (CXR), and no screening, using a healthcare payer perspective over a lifetime horizon. Sensitivity analyses were also performed. Main outcomes were costs, quality-adjusted life-years (QALYs), life expectancy life-years (LYs), incremental cost-effectiveness ratios (ICERs), and deaths from lung cancer. The willingness-to-pay level was US$100,000 per QALY gained. RESULTS LDCT yielded the greatest benefits with the lowest cost in Japan, but the ICERs of LDCT compared with CXR were US$3,001,304 per QALY gained for American men and US$2,097,969 per QALY gained for American women. Cost-effectiveness was sensitive to the incidence of lung cancer. Probabilistic sensitivity analyses demonstrated that LDCT was cost-effective 99.3-99.7% for Japanese, no screening was cost-effective 77.7% for American men, and CXR was cost-effective 93.2% for American women. Compared with CXR, LDCT has the cumulative lifetime potential for 60-year-old Japanese to save US$117 billion, increase 2,339,349 QALYs and 3,020,102 LYs, and reduce 224,749 deaths, and the potential for 60-year-old Americans to cost US$120 billion, increase 48,651 QALYs and 67,988 LYs, and reduce 2,309 deaths. CONCLUSIONS This modelling study suggests that LDCT screening for never smokers has the greatest benefits and cost savings in Japan, but is not cost-effective in the United States. Assessing the risk of lung cancer in never smokers is important for introducing population-based LDCT screening.
Collapse
Affiliation(s)
- Akiko Kowada
- Department of Occupational Health, Kitasato University Graduate School of Medical Sciences, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0373, Japan.
- Health Sciences University of Hokkaido, 1757 Kanazawa, Tobetsu-cho, Ishikari-gun, Hokkaido, 061-0293, Japan.
| |
Collapse
|
9
|
Khezerloo D, Iranmakani S, Jahanshahi A, Mehnati P, Mortezazadeh T. Image quality and pulmonary nodule detectability at low-dose computed tomography (low kVp and mAs): A phantom study. JOURNAL OF MEDICAL SIGNALS & SENSORS 2022; 12:64-68. [PMID: 35265467 PMCID: PMC8804592 DOI: 10.4103/jmss.jmss_65_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 06/04/2021] [Accepted: 08/27/2021] [Indexed: 11/08/2022]
Abstract
Background: Nowadays, there has been a growing demand for low-dose computed tomography (LDCT) protocols. CT has a critical role in the management of the diagnosis chain of pulmonary disease, especially in lung cancer screening. There have been introduced several dose reduction methods, however, most of them are time-consuming, intricate, and vendor-based strategies that are hardly used in clinics routinely. This study aims to evaluate the image quality and pulmonary nodule detectability of LDCT protocols that are feasible and easy implemented. Image quality was analyzed in a general quality control phantom (Gammex) and then in a manmade lung phantom with nodules-equivalent objects. Methods: This study was designed in a two steps, in the first step, a feasible low-dose lung CT protocol was selected with quality assessment of accreditation phantom image. In the second step, the selected low-dose protocol with an appropriate image quality was performed on a manmade lung phantom in which there were objects equivalent to the pulmonary nodule. Finally, image quality parameters of the phantom at the appropriate scan protocol were compared with the standard protocol. Results: A reduction of about 17% of kVp and 46% in tube current leads to dose reduction by about 70%. The contrast-to-noise ratio in the low-dose protocol remained almost unchanged. The signal-to-noise ratio in the low-dose protocol decreased by approximately 32%, and the noise level has increased by about 1.5 times. However, this reduction method hardly affected the detectability of nodules in man-made pulmonary phantom. Conclusions: Here, we demonstrated that the LDCT scan has an insignificant effect on the perception of lung nodules. In this study, patient dose in lung CT was reduced by modifying of kVp and mAs about approximately 70%. Hence, to step in toward low-dose strategies in medical imaging clinics, using easy-implemented and feasible low-dose strategies may be helpful.
Collapse
|
10
|
Du Y, Sidorenkov G, Heuvelmans MA, Vliegenthart R, Groen HJ, Greuter MJ, de Bock GH. Lung cancer screening with low-dose CT: simulating the effect of starting screening at a younger age in women. Eur J Radiol 2022; 148:110182. [DOI: 10.1016/j.ejrad.2022.110182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 01/17/2022] [Accepted: 01/26/2022] [Indexed: 11/03/2022]
|
11
|
Vonder M, Dorrius MD, Vliegenthart R. Latest CT technologies in lung cancer screening: protocols and radiation dose reduction. Transl Lung Cancer Res 2021; 10:1154-1164. [PMID: 33718053 PMCID: PMC7947397 DOI: 10.21037/tlcr-20-808] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The aim of this review is to provide clinicians and technicians with an overview of the development of CT protocols in lung cancer screening. CT protocols have evolved from pre-fixed settings in early lung cancer screening studies starting in 2004 towards automatic optimized settings in current international guidelines. The acquisition protocols of large lung cancer screening studies and guidelines are summarized. Radiation dose may vary considerably between CT protocols, but has reduced gradually over the years. Ultra-low dose acquisition can be achieved by applying latest dose reduction techniques. The use of low tube current or tin-filter in combination with iterative reconstruction allow to reduce the radiation dose to a submilliSievert level. However, one should be cautious in reducing the radiation dose to ultra-low dose settings since performed studies lacked generalizability. Continuous efforts are made by international radiology organizations to streamline the CT data acquisition and image quality assurance and to keep track of new developments in CT lung cancer screening. Examples like computer-aided diagnosis and radiomic feature extraction are discussed and current limitations are outlined. Deep learning-based solutions in post-processing of CT images are provided. Finally, future perspectives and recommendations are provided for lung cancer screening CT protocols.
Collapse
Affiliation(s)
- Marleen Vonder
- Department of Epidemiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Monique D Dorrius
- Department of Epidemiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Rozemarijn Vliegenthart
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
12
|
Cohen SL, Wang JJ, Chan N, O’Connell W, Shah R, Sanelli P, Raoof S. Lung Cancer Screening CT. Chest 2019; 156:1214-1222. [DOI: 10.1016/j.chest.2019.07.024] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Revised: 07/12/2019] [Accepted: 07/31/2019] [Indexed: 12/15/2022] Open
|
13
|
Wang GX, Baggett TP, Pandharipande PV, Park ER, Percac-Lima S, Shepard JAO, Fintelmann FJ, Flores EJ. Barriers to Lung Cancer Screening Engagement from the Patient and Provider Perspective. Radiology 2019; 290:278-287. [PMID: 30620258 DOI: 10.1148/radiol.2018180212] [Citation(s) in RCA: 109] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Lung cancer remains the leading cause of cancer mortality in the United States. Lung cancer screening (LCS) with low-dose CT reduces mortality among high-risk current and former smokers and has been covered by public and private insurers without cost sharing since 2015. Patients and referring providers confront numerous barriers to participation in screening. To best serve in multidisciplinary efforts to expand LCS nationwide, radiologists must be knowledgeable of these challenges. A better understanding of the difficulties confronted by other stakeholders will help radiologists continue to collaboratively guide the growth of LCS programs in their communities. This article reviews barriers to participation in LCS for patients and referring providers, as well as possible solutions and interventions currently underway.
Collapse
Affiliation(s)
- Gary X Wang
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| | - Travis P Baggett
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| | - Pari V Pandharipande
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| | - Elyse R Park
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| | - Sanja Percac-Lima
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| | - Jo-Anne O Shepard
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| | - Florian J Fintelmann
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| | - Efren J Flores
- From the Department of Radiology (G.X.W., P.V.P., J.O.S., F.J.F., E.J.F.), Division of General Internal Medicine (T.P.B., S.P.L.), and Department of Psychiatry (E.R.P.), Harvard Medical School, Massachusetts General Hospital, 55 Fruit St, Founders 202, Boston, MA 02114; and Institute for Technology Assessment (P.V.P.), Mongan Institute Health Policy Center (E.R.P.), and Tobacco Research and Treatment Center (E.R.P., T.P.B.), Massachusetts General Hospital, Boston, Mass
| |
Collapse
|
14
|
Nawa T. Low-dose CT screening for lung cancer reduced lung cancer mortality in Hitachi City. Int J Radiat Biol 2018; 95:1441-1446. [DOI: 10.1080/09553002.2018.1511930] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Takeshi Nawa
- Department of Respiratory Medicine, Hitachi General Hospital Hitachi Ltd, Hitachi City, Japan
| |
Collapse
|