Viry A, Vitzthum V, Monnin P, Bize J, Rotzinger D, Racine D. Optimization of CT pulmonary angiography for pulmonary embolism using task-based image quality assessment and diagnostic reference levels: A multicentric study. Phys Med 2024; 121:103365. [PMID: 38663347 DOI: 10.1016/j.ejmp.2024.103365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/12/2024] [Accepted: 04/19/2024] [Indexed: 05/12/2024] Open
Abstract
PURPOSE To establish size-specific diagnostic reference levels (DRLs) for pulmonary embolism (PE) based on patient CT examinations performed on 74 CT devices. To assess task-based image quality (IQ) for each device and to investigate the variability of dose and IQ across different CTs. To propose a dose/IQ optimization. METHODS 1051 CT pulmonary angiography dose data were collected. DRLs were calculated as the 75th percentile of CT dose index (CTDI) for two patient categories based on the thoracic perimeters. IQ was assessed with two thoracic phantom sizes using local acquisition parameters and three other dose levels. The area under the ROC curve (AUC) of a 2 mm low perfused vessel was assessed with a non-prewhitening with eye-filter model observer. The optimal IQ-dose point was mathematically assessed from the relationship between IQ and dose. RESULTS The DRLs of CTDIvol were 6.4 mGy and 10 mGy for the two patient categories. 75th percentiles of phantom CTDIvol were 6.3 mGy and 10 mGy for the two phantom sizes with inter-quartile AUC values of 0.047 and 0.066, respectively. After the optimization, 75th percentiles of phantom CTDIvol decreased to 5.9 mGy and 7.55 mGy and the interquartile AUC values were reduced to 0.025 and 0.057 for the two phantom sizes. CONCLUSION DRLs for PE were proposed as a function of patient thoracic perimeters. This study highlights the variability in terms of dose and IQ. An optimization process can be started individually and lead to a harmonization of practice throughout multiple CT sites.
Collapse
Affiliation(s)
- Anaïs Viry
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland.
| | - Veronika Vitzthum
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - Pascal Monnin
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - Julie Bize
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - David Rotzinger
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011, Lausanne, Switzerland
| | - Damien Racine
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| |
Collapse
|
2
|
Kobayashi D, Hayashi H, Nishigami R, Maeda T, Asahara T, Kanazawa Y, Katsumata A, Kimoto N, Yamamoto S. A blurring correction method suitable to analyze quantitative x-ray images derived from energy-resolving photon counting detector. Phys Med Biol 2024; 69:075023. [PMID: 38452379 DOI: 10.1088/1361-6560/ad3119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/07/2024] [Indexed: 03/09/2024]
Abstract
Objective.The purpose of this study is to propose a novel blurring correction method that enables accurate quantitative analysis of the object edge when using energy-resolving photon counting detectors (ERPCDs). Although the ERPCDs have the ability to generate various quantitative analysis techniques, such as the derivations of effective atomic number (Zeff) and bone mineral density values, at the object edge in these quantitative images, accurate quantitative information cannot be obtained. This is because image blurring prevents the gathering of accurate primary x-ray attenuation information.Approach.We developed the following procedure for blurring correction. A 5 × 5 pixels masking region was set as the processing area, and the pixels affected by blurring were extracted from the analysis of pixel value distribution. The blurred pixel values were then corrected to the proper values estimated by analyzing minimum and/or maximum values in the set mask area. The suitability of our correction method was verified by a simulation study and an experiment using a prototype ERPCD.Main results. WhenZeffimage of aluminum objects (Zeff= 13) were analyzed without applying our correction method, regardless of raw data or correction data applying a conventional edge enhancement method, the properZeffvalues could not be derived for the object edge. In contrast, when applying our correction method, 82% of pixels affected by blurring were corrected and the properZeffvalues were calculated for those pixels. As a result of investigating the applicability limits of our method through simulation, it was proven that it works effectively for objects with 4 × 4 pixels or more.Significance. Our method is effective in correcting image blurring when the quantitative image is calculated based on multiple images. It will become an in-demand technology for putting a quantitative diagnosis into actual medical examinations.
Collapse
Affiliation(s)
- Daiki Kobayashi
- Graduate School of Medical Sciences, Kanazawa University, Ishikawa, 920-0942, Japan
| | - Hiroaki Hayashi
- College of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Ishikawa, 920-0942, Japan
| | - Rina Nishigami
- Graduate School of Medical Sciences, Kanazawa University, Ishikawa, 920-0942, Japan
| | - Tatsuya Maeda
- Graduate School of Medical Sciences, Kanazawa University, Ishikawa, 920-0942, Japan
| | - Takashi Asahara
- Graduate School of Medical Sciences, Kanazawa University, Ishikawa, 920-0942, Japan
| | - Yuki Kanazawa
- Graduate School of Biomedical Sciences, Tokushima University, Tokushima, 770-8503, Japan
| | | | | | | |
Collapse
|
3
|
Huo B, Chen X, Xu Z, He D, Wang J. Exposure frequency and radiation dose from CT examinations in Huaian. RADIATION PROTECTION DOSIMETRY 2024; 200:396-402. [PMID: 38195745 DOI: 10.1093/rpd/ncad302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 11/12/2023] [Accepted: 11/22/2023] [Indexed: 01/11/2024]
Abstract
This study quantified the exposure frequency and established the local diagnostic reference levels (DRLs) for the most common computed tomography (CT) examinations. A combined method census and sampling survey was used to quantify both frequency and radiation dose of CT examinations. Data were acquired through Picture Archiving and Communication System (PACS) or Radiology Information System (RIS). The annual frequency of CT examinations was 239.8 per 1000 inhabitants. The P75 of volume CT dose index (CTDIvol) to adult patients from CT scanning for head, chest, abdomen and lumbar spine examinations were 63.0, 12.4, 20.0 and 24.0 mGy, respectively. The P75 of dose-length product were 858.6, 416.0, 620.7 and 559.2 mGy·cm, respectively. This dose audit of CT practice can act as a starting point for establishing Huaian local DRLs and could be a reference for dose optimisation in China. This study compared DRLs in different countries and analysed some reasons for the rapid growth of CT examination frequency in Huaian.
Collapse
Affiliation(s)
- Binbin Huo
- Occupational Health Division, Huaian Center for Disease Control and Prevention, Huaian, Jiangsu 223002, China
| | - Xiaomin Chen
- Occupational Health Division, Huaian Center for Disease Control and Prevention, Huaian, Jiangsu 223002, China
| | - Zhiyong Xu
- Occupational Health Division, Huaian Center for Disease Control and Prevention, Huaian, Jiangsu 223002, China
| | - Dongdong He
- Occupational Health Division, Huaian Center for Disease Control and Prevention, Huaian, Jiangsu 223002, China
| | - Jin Wang
- Radiation Protection Institute, Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, Jiangsu 221005, China
| |
Collapse
|
4
|
Simantirakis G, Hourdakis CJ, Kalathaki M, Liotsou V, Nikolaou M, Pafilis C, Thrapsanioti Z, Tritakis P, Carinou E. Updating national diagnostic reference levels for computed tomography in Greece: Challenges on patient protection optimisation. Eur J Radiol 2024; 175:111429. [PMID: 38508091 DOI: 10.1016/j.ejrad.2024.111429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/18/2024] [Accepted: 03/13/2024] [Indexed: 03/22/2024]
Abstract
The escalating use of Computed Tomography (CT) imaging necessitates establishment and periodic revision of Diagnostic Reference Levels (DRLs) to ensure patient protection optimization. This paper presents the outcomes of a national survey conducted from 2019 to 2022, focusing on revising DRLs for adult CT examinations. Dosimetric data from 127 scanners in 120 medical facilities, representing 25% of the country's CT scanners, were collected, emphasizing geographic distribution and technology representation. Τhe parameters used for DRLs were the CTDIvol and the DLP of a typical acquisition of the region of interest (scan DLP). In addition to the 7 CT examination for which the DRL values were revised, establishment of DRLs for neck, cervical spine, pelvic bones-hips, coronary artery calcium (Ca) score and cardiac computed tomography angiography (CCTA) examinations was performed. Revised DRLs exhibited a 15 % average decrease in CTDIvol and a 7 % average decrease in scan DLP from the initial DRLs. This reduction of dosimetric values is relatively low compared to other national studies. The findings revealed wide variations in dosimetric values and scan lengths among scanners, emphasizing the need for standardization and optimization. Incorporation of advanced technologies like Iterative Reconstruction (IR) showcased potential for further dose reduction, yet challenges in uniform implementation persist. The study underscores the importance of ongoing optimisation efforts, particularly in the context of increased CT utilization and evolving technology. The revised DRLs have been officially adopted in Greece, emphasizing the commitment to safe and effective CT practices.
Collapse
Affiliation(s)
- George Simantirakis
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece.
| | - Costas J Hourdakis
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| | - Maria Kalathaki
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| | - Vasiliki Liotsou
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| | - Magda Nikolaou
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| | - Christos Pafilis
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| | - Zoi Thrapsanioti
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| | - Panagiotis Tritakis
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| | - Eleftheria Carinou
- Greek Atomic Energy Commission, P.O. Box 60092, 153 10, Agia Paraskevi, Athens, Greece
| |
Collapse
|
5
|
Yagahara A, Ando D, Oda M. Demonstration of Japanese radiographic examination codes in establishing typical values for a wide variety of general radiography examinations. Sci Rep 2024; 14:2249. [PMID: 38278840 PMCID: PMC10817891 DOI: 10.1038/s41598-024-52294-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Accepted: 01/16/2024] [Indexed: 01/28/2024] Open
Abstract
The purpose of this study was to demonstrate Japanese radiographic examination codes JJ1017 in establishing typical values for a wide variety of general radiography. About 200,000 sets of examination data were collected, including exposure conditions, JJ1017 code applied, examination room numbers and patient information. Typical values for adults, children, and infants were calculated from the collected data, and the following items were examined: comparing typical values of general radiography in Japan DRLs 2015 and typical values in a facility; comparison of typical values between X-ray equipment for examinations of DRLs 2015; comparison of typical values for different procedures at the same anatomical site; identification of examination items associated with high radiation doses. The total numbers of JJ1017 codes applicable to the examinations were 45,372 for adults, 542 for children, and 2339 for infants. To calculate the typical values and compare these with the DRLs, we used a combination of JJ1017 anatomical codes, posture codes, and direction of radiation codes. The combination of these codes allowed the calculation of a typical value and comparison with DRLs 2015. Comparison between devices reveals differences in radiation doses and provides an opportunity to review the characteristics of the devices and their operation to suggest dose reductions. By calculating typical values for examination items for which the DRLs were not available, we were able to identify examination items with high doses in a facility and suggest items that should be audited in the facility.
Collapse
Affiliation(s)
- Ayako Yagahara
- Faculty of Health Sciences, Hokkaido University of Science, Sapporo, Japan.
| | - Daisuke Ando
- Department of Radiology, Southern TOHOKU Proton Therapy Center, Koriyama, Japan
| | - Makoto Oda
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Japan
| |
Collapse
|
6
|
Aldahery ST. Assessment of radiographers' knowledge about radiation doses and DRLs in computed tomography departments in Jeddah, Saudi Arabia: A cross-sectional study. Saudi Pharm J 2023; 31:101820. [PMID: 37928978 PMCID: PMC10622684 DOI: 10.1016/j.jsps.2023.101820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Accepted: 10/08/2023] [Indexed: 11/07/2023] Open
Abstract
Objective To assess radiographers' understanding of radiation safety considering the newly approved national diagnostic reference levels (DRLs) as an optimization tool for radiation dose. Methods A cross-sectional study was conducted in Saudi Arabia among radiographers working at local hospitals in Jeddah city from February to March 2022. The survey comprised of 22 questions involving demographic information; and general information related to radiation dose; CTDIvol and DRLs. Data were analyzed using IBM SPSS Statistics version 26. Chi-square test was used to compare demographic groups regarding their distribution of responses with 0.05 as the level of significance. Results A total of 169 radiographers participated in the study (39 % females, 60 % males). Most of the participants (91 %) were aware of the description of the ALARA principle. It was noted that (47 %) of the participants indicated that the routine scanning protocols are designed by the radiologists. The majority of them (78 %) were confident to manipulate the CT scanning parameters properly. In addition, half of the participants (53 %) were aware of the CTDIvol and DLP. Unexpectedly, none of the demographic variables were significantly associated with the radiographers' knowledge about radiation dose, p-values are > 0.05. Conclusion Although radiographers demonstrated good knowledge of radiation protection, limited awareness of DRLs was noted among radiographers and lack of implementing and optimizing the local dose of the DRLs in this study. Therefore, education and training for healthcare professionals including radiographers are necessary to enhance clinical practical performance in radiology departments.
Collapse
|
7
|
Greffier J, Van Ngoc Ty C, Fitton I, Frandon J, Beregi JP, Dabli D. Spectral performance of two split-filter dual-energy CT systems: A phantom study. Med Phys 2023; 50:6828-6835. [PMID: 37672341 DOI: 10.1002/mp.16701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Revised: 07/31/2023] [Accepted: 07/31/2023] [Indexed: 09/08/2023] Open
Abstract
BACKGROUND Recently, a second generation of split filter dual-energy CT (SFCT) platform has been developed. The thicknesses of the gold and tin filters used to obtain both low- and high-energy spectra have been changed. These differences in filter thickness may affect the spectral separation between the two spectra and thus the quality of spectral images. PURPOSE To compare the spectral performance of two Split-Filter Dual-Energy CT systems (SFCT-1st and SFCT-2nd ) on virtual monoenergetic images (VMIs) and iodine map. METHODS A Multi-Energy CT phantom was scanned on two SFCT with a tube voltage of 120 kVp for both systems (SFCT-1st -120 and SFCT-2nd -120) and 140 kVp only for the second generation (SFCT-2nd -140). Acquisitions were performed on the phantom with a CTDIvol close to 11 mGy. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated on VMIs from 40 to 70 keV. A detectability index (d') was computed to assess the detection of two contrast-enhanced lesions on VMIs. Hounsfield Unit (HU) accuracy was assessed on VMIs and the accuracy of iodine concentration was assessed on iodine maps. RESULTS For all keV, noise magnitude values were lower with the SFCT-2nd -120 than with the SFCT-1st -120 (on average: -22.5 ± 2.9%) and higher with the SFCT-2nd -140 than with the SFCT-2nd -120 (on average: 25.0 ± 6.2%). Average NPS spatial frequencies (fav ) were lower with the SFCT-1st -120 than with the SFCT-2nd -120 (-6.0 ± 0.5%) and the SFCT-2nd -140 (-3.6 ± 1.6%). Similar TTF50% values were found for both systems and both kVp for blood and iodine inserts at 2 mg/mL (0.29 ± 0.01 mm-1 ) and at 4 mg/mL (0.31 ± 0.01 mm-1 ). d' values peaked at 40 keV for the SFCT-2nd and at 70 keV for the SFCT-1st . Highest d' values were found for the SFCT-2nd -120 for both simulated lesions. Accuracy of HU values and iodine concentration was higher with the SFCT-2nd than with the SFCT 1st . CONCLUSION Compared to the SFCT-1st , with similar spatial resolution and noise texture values, the SFCT-2nd -120 exhibited the lowest values for noise magnitude, the highest detectability index values, and more accurate HU values and iodine concentrations.
Collapse
Affiliation(s)
- Joël Greffier
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Claire Van Ngoc Ty
- Université de Paris, Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Department of Radiology, Paris, France
| | - Isabelle Fitton
- Université de Paris, Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Department of Radiology, Paris, France
| | - Julien Frandon
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Jean-Paul Beregi
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Djamel Dabli
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| |
Collapse
|
8
|
Bouchareb Y, Al-Maimani A, Al-Balushi AY, Al-Kalbani M, Al-Maskari H, Al-Dhuhli H, Al-Kindi F. Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman. RADIATION PROTECTION DOSIMETRY 2023; 199:2148-2155. [PMID: 37594414 DOI: 10.1093/rpd/ncad225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 07/25/2023] [Accepted: 07/31/2023] [Indexed: 08/19/2023]
Abstract
This study aimed to estimate diagnostic reference levels (DRLs) for the most frequent computed tomography (CT) imaging examinations to monitor and better control radiation doses delivered to patients. Seven CT imaging examinations: Head, Chest, Chest High Resolution (CHR), Abdomen Pelvis (AP), Chest Abdomen Pelvis (CAP), Kidneys Ureters Bladder (KUB) and Cardiac, were considered. CT dosimetric quantities and patient demographics were collected from data storage systems. Local typical values for DRLs were calculated for CTDIvol (mGy), dose length product (DLP) (mGy·cm) and effective doses (mSv) were estimated for each examination. The calculated DRLs were given as (median CTDIvol (mGy):median DLP (mGy·cm)): Head: 39:657; Chest: 13:451; CHR: 6:228; AP: 12:578; CAP: 20:807; KUB: 7:315, and Cardiac: 2:31. Estimated effective doses for Head, Chest, CHR, AP, CAP, KUB and Cardiac were 1.3, 12.7, 6.3, 12.5, 18.1, 5.8 and 0.8 mSv, respectively. The estimated DRLs will act as guidance doses to prevent systematic excess of patient doses.
Collapse
Affiliation(s)
- Yassine Bouchareb
- Sultan Qaboos University, College of Medicine & Health Sciences, Muscat, Oman
| | - Amal Al-Maimani
- Sultan Qaboos University Hospital, Radiology and Molecular Imaging, Muscat, Oman
| | | | | | | | - Humoud Al-Dhuhli
- Sultan Qaboos University Hospital, Radiology and Molecular Imaging, Muscat, Oman
| | - Faiza Al-Kindi
- Radiology Department, Royal Hospital, PO. Box 1331, Muscat, Oman
| |
Collapse
|
9
|
Arlany L, Toh HG, Nazir B, Ng JJ, Tay YH, Tay YS, Poon CJX, Lee LN, Fum WKS, Lee EYT, Mariah SI, Fortier MV, Tham WP, Chew LL, Chong KHE, Chong LR. Establishment of CT diagnostic reference levels (DRLs) for a Singapore healthcare cluster. Radiography (Lond) 2023; 29:184-189. [PMID: 36469993 DOI: 10.1016/j.radi.2022.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 11/08/2022] [Accepted: 11/09/2022] [Indexed: 12/09/2022]
Abstract
INTRODUCTION The use of computed tomography (CT) in healthcare institutions has increased rapidly in recent years. The Singapore Health Services (SingHealth) cluster of healthcare institutions has taken the first step in establishing a local cluster-wide CT Diagnostic Reference Levels (DRL) in Singapore. CT dose data from each institution were collected through two primary dosimetry metrics: volume CT dose index (CTDIvol measured in mGy) and dose-length product (DLP measured in mGy.cm). METHODS Data from 19 CT scanners in seven institutions under one of Singapore healthcare cluster were retrospectively collected and analysed. The five common adult CT examinations analysed were CT Brain (non-contrast enhanced), CT Chest (IV contrast enhanced), CT Kidney-Ureter-Bladder (CT KUB, non-contrast enhanced), CT Pulmonary Angiogram (CT PA, IV contrast enhanced) and CT Abdomen-Pelvis (CT AP, IV contrast enhanced, single phase). Median CTDIvol and DLP values for the five CT examinations from each institution were derived, with the cluster DRLs determined as the 75th percentile of the distribution of the institution median dose values. RESULTS A total of 2413 dose data points were collected over a six-month period from June to November 2020. The cluster CT DRLs for the five CT examinations were determined to be 47 mGy and 820 mGy.cm for CT Brain, 5.4 mGy and 225 mGy.cm for CT Chest, 6.7 mGy and 248 mGy.cm for CT PA, 4.6 mGy and 190 mGy.cm for CT KUB and 6.9 mGy and 349 mGy.cm for CT AP. CONCLUSION The establishment of the cluster CT DRLs provided individual institutions with a better understanding if their CT doses are unusually high or low, while emphasising that these DRLs are not meant as hard dose limits or constraints to follow strictly.
Collapse
Affiliation(s)
- L Arlany
- Sengkang General Hospital, 110 Sengkang East Way, Singapore 544886.
| | - H G Toh
- Singapore General Hospital, Outram Road Singapore, Singapore 169608
| | - B Nazir
- National Cancer Centre Singapore, 11 Hospital Crescent, Singapore 169610
| | - J J Ng
- Sengkang General Hospital, 110 Sengkang East Way, Singapore 544886
| | - Y H Tay
- Kandang Kerbau Hospital, 100 Bukit Timah Road, Singapore 229899
| | - Y S Tay
- Singapore General Hospital, Outram Road Singapore, Singapore 169608
| | - C J X Poon
- Changi General Hospital, 2 Simei Street 3, Singapore 529889
| | - L N Lee
- Singapore General Hospital, Outram Road Singapore, Singapore 169608
| | - W K S Fum
- Singapore General Hospital, Outram Road Singapore, Singapore 169608
| | - E Y T Lee
- National Heart Centre Singapore, 5 Hospital Drive, Singapore 169609
| | - S I Mariah
- National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433
| | - M V Fortier
- Kandang Kerbau Hospital, 100 Bukit Timah Road, Singapore 229899
| | - W P Tham
- Singapore General Hospital, Outram Road Singapore, Singapore 169608
| | - L L Chew
- National Cancer Centre Singapore, 11 Hospital Crescent, Singapore 169610
| | - K H E Chong
- National Heart Centre Singapore, 5 Hospital Drive, Singapore 169609
| | - L R Chong
- Changi General Hospital, 2 Simei Street 3, Singapore 529889
| |
Collapse
|
10
|
Identification and characterization of patients being exposed to computed-tomography associated radiation-doses above 100 mSv in a real-life setting. Eur J Radiol Open 2022; 10:100470. [PMID: 36590327 PMCID: PMC9800257 DOI: 10.1016/j.ejro.2022.100470] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 12/16/2022] [Accepted: 12/20/2022] [Indexed: 12/24/2022] Open
Abstract
Rationale and objectives Patients receiving high cumulative effective doses (CED) from recurrent computed tomography (CT) in a real-life setting are not well identified. Evaluation of causes and patient characteristics may help to define individuals potentially at risk of radiation-induced secondary malignancies. Materials and methods Patients who received a CED > 100 mSv from CT scans during October 2012 and April 2020 at a tertiary university center were identified with the help of a radiological radiation dose monitoring system. The primary disease and referral diagnosis, number of CT exams, time period, age, BMI and gender distribution of the 1000 patients with the highest CED were analysed. Results 3431 patients had a CED of more than 100 mSv, which corresponded to 2.75% of all patients who received a CT exam. From the 1000 patients with the highest CED, mean number of CT exams per patient was 14.6, mean CED was 257 mSv (SD 98, range 177-1339). Mean age of patients was 63.9 years (SD 10.6), male to female ratio 3:2, and mean BMI 28.7 kg/m2 (SD 5.5). 728 (72.9%) patients had cancer. The leading primary diagnosis was liver cirrhosis in 197 patients and 103 patients had a liver transplantation. In patients with liver cirrhosis, 750 exams were indicated for the follow-up of the disease, 662 for the clarification of an acute clinical condition, and 202 for CT-guided stereotactic radiofrequency ablation. Conclusion Recurrent CT scans of patients with cancer, liver cirrhosis and liver transplantation may lead to critically high CED.
Collapse
|
11
|
Jusoh II, Abdullah KA, Ali MH. DIAGNOSTIC REFERENCE LEVELS FOR COMMON CT EXAMINATIONS: RESULTS FROM A STATEWIDE DOSE SURVEY. RADIATION PROTECTION DOSIMETRY 2022; 198:1417-1423. [PMID: 36093894 DOI: 10.1093/rpd/ncac182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/09/2022] [Accepted: 08/17/2022] [Indexed: 06/15/2023]
Abstract
The aim of this study was to investigate the current radiation doses for CT examinations throughout a state in Malaysia and, based on this data, to propose local diagnostic reference levels (DRLs) for the most common CT examinations. A study was conducted in three of the four hospitals that have provided CT services throughout the state. A survey booklet was designed to facilitate collection of pertinent CT scan data. The following information were extracted and recorded for each study: tube voltage, tube current, number of scans phases, CT dose index volume (CTDIvol) and dose length product (DLP). Proposed local DRLs of CT brain and thorax were up to 12% lower than the current national DRLs. However, an increase of DLP (median value) for CT abdomen was also found as compared to the 75th percentile of national DRLs. Therefore, considerable optimisation should be made to achieve a better dose reduction.
Collapse
Affiliation(s)
- Irwan Iskandar Jusoh
- School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Kuala Nerus, Terengganu 21300, Malaysia
| | - Kamarul Amin Abdullah
- School of Medical Imaging, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Kuala Nerus, Terengganu 21300, Malaysia
| | - Mohd Hanafi Ali
- Discipline of Medical Imaging Science, Sydney School of Health Sciences, Faculty of Medicine and Health, Level 7, University of Sydney, D18 Susan Wakil Health Building, Western Avenue, Camperdown, NSW 2006, Australia
| |
Collapse
|
12
|
Tonkopi E, Wikan EJ, Hovland TO, Høgset S, Kofod TA, Sefenu SK, Hughes-Ryan E, d´Entremont-O´Connell D, Gunn C, Holter T, Johansen S. A survey of local diagnostic reference levels for the head, thorax, abdomen and pelvis computed tomography in Norway and Canada. Acta Radiol Open 2022; 11:20584601221131477. [PMID: 36225897 PMCID: PMC9549116 DOI: 10.1177/20584601221131477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 09/22/2022] [Indexed: 11/05/2022] Open
Abstract
Background Computed tomography (CT) contributes to 60% of the collective dose in medical
imaging. Literature has demonstrated that patient dose varies across regions
and countries. Establishing diagnostic reference levels (DRLs) contributes
to the optimization of clinical practices and radiation protection. Purpose To survey the dose indices (CTDIvol and dose-length product) for frequently
performed CT examinations from the chosen hospitals in Norway and Canada and
to determine local DRLs (LDRLs) based on the collected data. Material and Methods The survey included eight scanners from two Norwegian hospitals and four
scanners from four Canadian hospitals. Dosimetry data were collected for the
following routine CT examinations: head, contrast-enhanced thorax, and
abdomen and pelvis. Overall 480 adult average-sized patients from Norway and
360 from Canada were included in the survey. The LDRLs were determined as
the 75th percentile of distributions of median values of dose indicators
from different CT scanners. The differences in dose between scanners were
determined using single-factor ANOVA. Results The LDRLs determined in Norway were higher overall than in Canada. The
obtained values were compared to the national DRLs. The dose from several
scanners in Norway exceeded national Norwegian DRLs, while Canadian LDRLs
were below the Canadian reference levels. The differences between the means
of the dose distributions from each scanner were statistically significant
(p < 0.05) for all examinations with exception of
identical scanners located in the same hospital and using the same
protocols. Conclusion Observed dose variations even in the same hospital, or from the same scanner
model confirmed the need for CT protocol optimization.
Collapse
Affiliation(s)
- Elena Tonkopi
- Department of Diagnostic Imaging,
Nova Scotia
Health Authority, Halifax, NS,
Canada,Department of Radiation Oncology,
Dalhousie
University, Halifax, NS, Canada,Department of Diagnostic Radiology,
Dalhousie
University, Halifax, NS, Canada
| | | | | | - Sivert Høgset
- Health faculty,
Oslo
Metropolitan University, Oslo,
Norway
| | | | | | - Emily Hughes-Ryan
- School of Health Sciences,
Dalhousie
University, Halifax, NS, Canada
| | | | - Catherine Gunn
- Department of Radiation Oncology,
Dalhousie
University, Halifax, NS, Canada,School of Health Sciences,
Dalhousie
University, Halifax, NS, Canada
| | - Tanja Holter
- Department of Physics and
Computational Radiology, Oslo University
Hospital, Oslo Norway
| | - Safora Johansen
- Health faculty,
Oslo
Metropolitan University, Oslo,
Norway,Department of Cancer Treatment,
Oslo
University Hospital, Oslo, Norway,Safora Johansen, Oslo Metropolitan
University and Oslo Hospital, Pilestredet 48, Oslo 0130, Norway.
| |
Collapse
|
13
|
Almujally A, Alenezi S, Alddosary KN, Otayni A, Sulieman A, Abdelghani A, Alkhybari E, Tamam N, Bradley D. Abdomen and pelvis computed tomography procedure: Effective dose assessment and establishment of a local diagnostic reference level. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
Patient dose in CT angiography examinations: An institutional survey. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
15
|
Assessment of diagnostic reference levels awareness and knowledge amongst CT radiographers in Saudi Arabia. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2022. [DOI: 10.1016/j.jrras.2022.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
16
|
Hasan N, Rizk C, Babikir E. National diagnostic reference levels based on clinical indications and patient size for adults’ computed tomography in the Kingdom of Bahrain. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110147] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
17
|
El Mansouri M, Choukri A, Nhila O, Talbi M. Evaluation of radiation dose in lumbar spine computed tomography in a single Moroccan center. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
18
|
Greffier J, Viry A, Barbotteau Y, Frandon J, Loisy M, Oliveira F, Beregi JP, Dabli D. Phantom task‐based image quality assessment of three generations of rapid kV‐switching dual‐energy CT systems on virtual monoenergetic images. Med Phys 2022; 49:2233-2244. [DOI: 10.1002/mp.15558] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/11/2022] [Accepted: 02/11/2022] [Indexed: 11/10/2022] Open
Affiliation(s)
- Joël Greffier
- Department of medical imaging CHU Nîmes Univ Montpellier, Nîmes Medical Imaging Group Nîmes 2992 France
| | - Anaïs Viry
- Institute of Radiation Physics Lausanne University Hospital and University of Lausanne Rue du Grand‐Pré 1 Lausanne 1007 Switzerland
| | - Yves Barbotteau
- Hôpital Privé Clairval – Service d'Imagerie 317, Bd du Redon Marseille 13009 France
| | - Julien Frandon
- Department of medical imaging CHU Nîmes Univ Montpellier, Nîmes Medical Imaging Group Nîmes 2992 France
| | - Maeliss Loisy
- Department of medical imaging CHU Nîmes Univ Montpellier, Nîmes Medical Imaging Group Nîmes 2992 France
| | - Fabien Oliveira
- Department of medical imaging CHU Nîmes Univ Montpellier, Nîmes Medical Imaging Group Nîmes 2992 France
| | - Jean Paul Beregi
- Department of medical imaging CHU Nîmes Univ Montpellier, Nîmes Medical Imaging Group Nîmes 2992 France
| | - Djamel Dabli
- Department of medical imaging CHU Nîmes Univ Montpellier, Nîmes Medical Imaging Group Nîmes 2992 France
| |
Collapse
|
19
|
Abdulkadir MK, Piersson AD, Musa GM, Audu SA, Abubakar A, Muftaudeen B, Umana JE. Assessment of diagnostic reference levels awareness and knowledge amongst CT radiographers. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [DOI: 10.1186/s43055-021-00444-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Reports indicated that numerous factors, including inadequate personnel knowledge, contributes to insufficient patient data for setting up diagnostic reference levels (DRLs) in developing countries. This study aims to evaluate the knowledge of DRLs as an optimisation tool amongst computed tomography (CT) radiographers in northern Nigeria. This is a quantitative cross-sectional study. A structured questionnaire was devised and distributed on site to sixty-two CT radiographers in northern Nigeria. A total of fifteen questions were included in the questionnaire focusing on DRLs, dose optimisation and dose descriptors generating quantitative data concerning overall CT radiographers’ perceived knowledge and awareness about DRLs.
Results
A response rate of 77.4% (48/62) was achieved. About 83.3% of the participants declare DRLs awareness, and 37.5% carried out a local dose survey. The percentage correctly perceived knowledge of concepts; DRLs was 45.8%, dose optimisation (42%) and CT dose descriptor (39%). Radiographers with work experience ranging from 4-10 years had the highest score.
Conclusion
In this survey, deficiencies were noted in radiographers’ knowledge about DRLs with precise knowledge gap in the implementation of local dose survey for DRLs and optimisation. There is a need for continuous radiographers’ training with greater emphasis on dose optimisation and institutional based dose evaluation.
Collapse
|
20
|
Suliman II, Bashier EH, Awad M, Ahmed I, Mohamed S, Ahmed NA. NATIONAL DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSES FOR STANDARD CT EXAMINATIONS IN SUDAN. RADIATION PROTECTION DOSIMETRY 2021; 196:1-9. [PMID: 34415339 DOI: 10.1093/rpd/ncab123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 06/14/2021] [Accepted: 07/16/2021] [Indexed: 06/13/2023]
Abstract
Radiation doses were determined to propose national diagnostic reference levels (NDRLs) and achievable doses (ADs) for computed tomography (CT) examinations in Sudan. Doses were estimated from retrospectively collected scan parameters for 1336 CT examinations of adult patients from 14 Sudanese hospitals using CT Expo 2.5 software. ADs and NDRLs were set at the 50th and 75th percentile of the hospital median dose distribution, respectively. The proposed CTDIvol (mGy) ADs ranged from: 10 (chest) to 64 (head), and that of the dose-length product (DLP; mGy.cm) ranged from 366 (chest) to 1225 (head). The proposed CTDIvol (mGy) NDRLs ranged from 15 kidney-ureter-bladder (KUB) to 79 (head), whereas that of the DLP (mGy.cm) ranged from 690 (chest) to 1490 (head). Current doses fell within the upper range of the doses presented in the literature emphasizing the need for implementation of the current ADs and NDRLs for CT to enhance patient protection and dose optimization in Sudan.
Collapse
Affiliation(s)
- I I Suliman
- Imam Mohammad Ibn Saud Islamic University (IMSIU), College of Science, Department of Physics, Riyadh 11642, Saudi Arabia
- Sudan Atomic Energy Commission, Radiation and Nuclear Safety Institute, PO Box 3001, Khartoum, Sudan
| | - Einas H Bashier
- Sudan Atomic Energy Commission, Radiation and Nuclear Safety Institute, PO Box 3001, Khartoum, Sudan
| | - Mustafa Awad
- Sudan Atomic Energy Commission, Radiation and Nuclear Safety Institute, PO Box 3001, Khartoum, Sudan
| | - Ibrahim Ahmed
- Sudan Atomic Energy Commission, Radiation and Nuclear Safety Institute, PO Box 3001, Khartoum, Sudan
| | - Suhair Mohamed
- Sudan Atomic Energy Commission, Radiation and Nuclear Safety Institute, PO Box 3001, Khartoum, Sudan
| | - Nada A Ahmed
- Sudan Atomic Energy Commission, Radiation and Nuclear Safety Institute, PO Box 3001, Khartoum, Sudan
- Taibah University, Faculty of Science, P.O. Box 344, Al-Madinah, Saudi Arabia
| |
Collapse
|
21
|
ALADA Dose Optimization in the Computed Tomography of the Temporal Bone: The Diagnostic Potential of Different Low-Dose CT Protocols. Diagnostics (Basel) 2021; 11:diagnostics11101894. [PMID: 34679601 PMCID: PMC8534882 DOI: 10.3390/diagnostics11101894] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/05/2021] [Accepted: 10/07/2021] [Indexed: 11/16/2022] Open
Abstract
Objective: Repeated computed tomography (CT) is essential for diagnosis, surgical planning and follow-up in patients with middle and inner ear pathology. Dose reduction to “as low as diagnostically acceptable” (ALADA) is preferable but challenging. We aimed to compare the diagnostic quality of images of subtle temporal bone structures produced with low doses (LD) and reference protocols (RP). Methods: Two formalin-fixed human cadaver heads were scanned using a 64-slice CT scanner and cone-beam CT (CBCT). The protocols were: RP (120 kV, 250 mA, CTDIvol 83.72 mGy), LD1 (100 kV, 80 mA, CTDIvol 26.79 mGy), LD2 (100 kV, 35 mA, CTDIvol 7.66 mGy), LD3 (80 kV, 40 mA, CTDIvol 4.82 mGy), and CBCT standard protocol. Temporal bone structures were assessed using a 5-point scale. Results: A median score of ≥2 was achieved with protocols such as the tendons of m. tensor tympani (RP/LD1/LD2/CBCT) and m. stapedius (CBCT), the incudostapedial joint (RP/LD1/CBCT), the incudomalleolar joint (RP/LD1/LD2/CBCT), the stapes feet (RP/LD1/CBCT), the stapes head (RP/LD1/LD2/CBCT), the tympanic membrane (RP/LD1/LD2/CBCT), the lamina spiralis ossea (none), the chorda tympani (RP/LD1/CBCT), and the modiolus (RP/LD1/LD2/CBCT). Adaptive statistical iterative reconstructions did not show advantages over the filtered back projection. Conclusions: LD protocols using a CTDIvol of 7.66 mGy may be sufficient for the identification of temporal bone structures.
Collapse
|
22
|
Diagnostic reference levels and median doses for common clinical indications of CT: findings from an international registry. Eur Radiol 2021; 32:1971-1982. [PMID: 34642811 PMCID: PMC8831291 DOI: 10.1007/s00330-021-08266-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 07/13/2021] [Accepted: 07/28/2021] [Indexed: 11/02/2022]
Abstract
OB JECTIVES The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry. METHODS Standardized data on 3.7 million CTs in adults were collected between 2016 and 2019 from 161 institutions across seven countries (United States of America (US), Switzerland, Netherlands, Germany, UK, Israel, Japan). DRLs (75th percentile) and median doses for volumetric CT-dose index (CTDIvol) and dose-length product (DLP) were assessed for each EUCLID category (chronic sinusitis, stroke, cervical spine trauma, coronary calcium scoring, lung cancer, pulmonary embolism, coronary CT angiography, hepatocellular carcinoma (HCC), colic/abdominal pain, appendicitis), and US radiation doses were compared with European. RESULTS The number of CT scans within EUCLID categories ranged from 8,933 (HCC) to over 1.2 million (stroke). There was greater variation in dose between categories than within categories (p < .001), and doses were significantly different between categories within anatomic areas. DRLs and median doses were assessed for all categories. DRLs were higher in the US for 9 of the 10 indications (except chronic sinusitis) than in Europe but with a significantly higher sample size in the US. CONCLUSIONS DRLs for CTDIvol and DLP for EUCLID clinical indications from diverse organizations were established and can contribute to dose optimization. These values were usually significantly higher in the US than in Europe. KEY POINTS • Registry data were used to create benchmarks for 10 common indications for CT identified by the European Society of Radiology. • Observed US radiation doses were higher than European for 9 of 10 indications (except chronic sinusitis). • The presented diagnostic reference levels and median doses highlight potentially unnecessary variation in radiation dose.
Collapse
|
23
|
Papanastasiou E, Protopsaltis A, Finitsis S, Hatzidakis A, Prassopoulos P, Siountas A. Institutional Diagnostic Reference Levels and Peak Skin Doses in selected diagnostic and therapeutic interventional radiology procedures. Phys Med 2021; 89:63-71. [PMID: 34352677 DOI: 10.1016/j.ejmp.2021.07.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 07/08/2021] [Accepted: 07/20/2021] [Indexed: 02/06/2023] Open
Abstract
PURPOSE Institutional (local) Diagnostic Reference Levels for Cerebral Angiography (CA), Percutaneous Transhepatic Cholangiography (PTC), Transarterial Chemoembolization (TACE) and Percutaneous Transhepatic Biliary Drainage (PTBD) are reported in this study. MATERIALS AND METHODS Data for air kerma-area product (PKA), air kerma at the patient entrance reference point (Ka,r), fluoroscopy time (FT) and number of images (NI) as well as estimates of Peak Skin Dose (PSD) were collected for 142 patients. Therapeutic procedure complexity was also evaluated, in an attempt to incorporate it into the DRL analysis. RESULTS Local PKA DRL values were 70, 34, 189 and 54 Gy.cm2 for CA, PTC, TACE and PTBD respectively. The corresponding DRL values for Ka,r were 494, 194, 1186 and 400 mGy, for FT they were 9.2, 14.2, 27.5 and 22.9 min, for the NI they were 844, 32, 602 and 13 and for PSD they were 254, 256, 1598 and 540 mGy respectively. PKA for medium complexity PTBD procedures was 2.5 times higher than for simple procedures. For TACE, the corresponding ratio was 1.6. PSD was estimated to be roughly 50% of recorded Ka,r for procedures in the head/neck region and 10% higher than recorded Ka,r for procedures in the body region. In only 5 cases the 2 Gy dose alarm threshold for skin deterministic effects was exceeded. CONCLUSION Procedure complexity can differentiate DRLs in Interventional Radiology procedures. PSD could be deduced with reasonable accuracy from values of Ka,r that are reported in every angiography system.
Collapse
Affiliation(s)
- Emmanouil Papanastasiou
- Medical Physics Laboratory, School of Medicine, Aristotle University of Thessaloniki, AHEPA University Hospital, Thessaloniki, Greece.
| | - Athanasios Protopsaltis
- Medical Physics Laboratory, School of Medicine, Aristotle University of Thessaloniki, AHEPA University Hospital, Thessaloniki, Greece
| | - Stefanos Finitsis
- Department of Radiology, School of Medicine, Aristotle University of Thessaloniki, AHEPA University Hospital, Thessaloniki, Greece
| | - Adam Hatzidakis
- Department of Radiology, School of Medicine, Aristotle University of Thessaloniki, AHEPA University Hospital, Thessaloniki, Greece
| | - Panos Prassopoulos
- Department of Radiology, School of Medicine, Aristotle University of Thessaloniki, AHEPA University Hospital, Thessaloniki, Greece
| | - Anastasios Siountas
- Medical Physics Laboratory, School of Medicine, Aristotle University of Thessaloniki, AHEPA University Hospital, Thessaloniki, Greece
| |
Collapse
|
24
|
Esmaeilyfard R, Samanipour A, Paknahad M. A cloud-fog software architecture for dental CBCT dose monitoring using the DICOM structured report: Automated establishment of DRL. Phys Med 2021; 89:147-150. [PMID: 34365119 DOI: 10.1016/j.ejmp.2021.07.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 07/29/2021] [Accepted: 07/29/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE The diagnostic reference level (DRL) has been established to optimize the diagnostic methods and reduce radiation dose during radiographic examinations. The aim of this study was to present a completely new solution based on Cloud-Fog software architecture for automatic establishment of the DRL values during dental cone-beam computed tomography (CBCT) according to digital imaging and communications in medicine (DICOM) structured reports. METHODS AND MATERIALS A Cloud-Fog software architecture was used for automatic data handling. This architecture used the DICOM structured reports as a source for extracting the required information by fog devices in the imaging center. These devices transferred the derived information to the cloud server. The cloud server calculated the value of indication-based DRL in dental CBCT imaging based upon the parameters and adequate quantities of the absorbed dose. The feedback of DRL value was continuously announced to the imaging centers in 6 phases. In each phase, the level of the dose was optimized in imaging centers. RESULTS The DRL value was established for 5-specific indications, including third molar teeth (511 mGy.cm2), implant (719 mGy.cm2), form and position anomalies of the tooth (408 mGy.cm2), dentoalveolar pathologies (612 mGy.cm2), and endodontics (632 mGy.cm2). The determination of the DRL value in each phase revealed a downward trend until stabilization. CONCLUSION The new solution presented in this study makes it possible to calculate and update the DRL value nationally and automatically among all centers. Also, the results showed that this approach is successful in establishing stabilized DRL values.
Collapse
Affiliation(s)
- Rasool Esmaeilyfard
- Computer Engineering and Information Technology Department, Shiraz University of Technology, Shiraz, Iran; Health Technology Research Center, Shiraz University of Technology, Shiraz, Iran
| | - Ali Samanipour
- Computer Engineering and Information Technology Department, Shiraz University of Technology, Shiraz, Iran
| | - Maryam Paknahad
- Oral and Dental Disease Research Center, Dental School, Shiraz University of Medical Sciences, Shiraz, Iran; Oral and Maxillofacial Radiology Department, Dental School, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
25
|
Assessment of task-based image quality for abdominal CT protocols linked with national diagnostic reference levels. Eur Radiol 2021; 32:1227-1237. [PMID: 34327581 PMCID: PMC8794993 DOI: 10.1007/s00330-021-08185-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 06/04/2021] [Accepted: 06/29/2021] [Indexed: 12/18/2022]
Abstract
Objectives To assess task-based image quality for two abdominal protocols on various CT scanners. To establish a relationship between diagnostic reference levels (DRLs) and task-based image quality. Methods A protocol for the detection of focal liver lesions was used to scan an anthropomorphic abdominal phantom containing 8- and 5-mm low-contrast (20 HU) spheres at five CTDIvol levels (4, 8, 12, 16, and 20 mGy) on 12 CTs. Another phantom with high-contrast calcium targets (200 HU) was scanned at 2, 4, 6, 10, and 15 mGy using a renal stones protocol on the same CTs. To assess the detectability, a channelized Hotelling observer was used for low-contrast targets and a non-prewhitening observer with an eye filter was used for high contrast targets. The area under the ROC curve and signal to noise ratio were used as figures of merit. Results For the detection of 8-mm spheres, the image quality reached a high level (mean AUC over all CTs higher than 0.95) at 11 mGy. For the detection of 5-mm spheres, the AUC never reached a high level of image quality. Variability between CTs was found, especially at low dose levels. For the search of renal stones, the AUC was nearly maximal even for the lowest dose level. Conclusions Comparable task-based image quality cannot be reached at the same dose level on all CT scanners. This variability implies the need for scanner-specific dose optimization. Key Points • There is an image quality variability for subtle low-contrast lesion detection in the clinically used dose range. • Diagnostic reference levels were linked with task-based image quality metrics. • There is a need for specific dose optimization for each CT scanner and clinical protocol.
Collapse
|
26
|
Abdulkadir MK, Izge IY, Yunusa GH, Mohammed A, Osman ND. Evaluation of age-based radiation dose in paediatric patients received from head CT examination at a tertiary hospital, Nigeria. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
27
|
Botwe BO, Schandorf C, Inkoom S, Faanu A, Rolstadaas L, Goa PE. National indication-based diagnostic reference level values in computed tomography: Preliminary results from Ghana. Phys Med 2021; 84:274-284. [PMID: 33775566 DOI: 10.1016/j.ejmp.2021.03.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 02/09/2021] [Accepted: 03/05/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE This study was conducted to develop national indication-based DRL values for common indications of adult computed tomography (CT) examinations for clinical application in Ghana. MATERIALS AND METHODS The methodological approach recommended by the International Commission on Radiological Protection (ICRP), Publication 135, for the development of DRLs, was employed. Studies on CT infrastructure, common indications and quality control tests were first undertaken. A sample of 20 CT dose descriptor/quantity data sets were collected from each centre for each indication. Overall, 3960 data sets were collected for all identified common indications from 71.4% of the total CT scanners in Ghana (25/35). The data were collected from image folders reported and accepted by radiologists. The objective image quality was assessed through a signal to noise ratio (SNR) analysis prior to using the data and extracting DRL values. RESULTS Clinical indications and their respective DRL values in terms of volume weighted CT dose index (CTDIvol) and dose length product (DLP) were cerebrovascular accident (CVA)/stroke (77 mGy; 1313 mGy.cm), head trauma/injury (76 mGy; 1596 mGy.cm), brain tumour/space occupying lesion (SOL) (77 mGy; 2696 mGy.cm), lung tumour/cancer (12 mGy; 828 mGy.cm) and chest lesion with chronic kidney disease (CKD) (13 mGy; 467 mGy.cm). Others were abdominopelvic lesion (17 mGy; 1299 mGy.cm), kidney stones (15 mGy; 731 mGy.cm), urothelial malignancy/CT-intravenous urogram (CT-IVU) (11 mGy; 1449 mGy.cm) and pulmonary embolism (PE) (14 mGy; 942 mGy.cm). CONCLUSION National Indication-based DRL values developed in this study are recommended to be used to manage CT radiation dose in Ghana.
Collapse
Affiliation(s)
- Benard Ohene Botwe
- Radiography Department, School of Biomedical and Allied Health Sciences, College of Health Sciences, University of Ghana, Korle-Bu Campus, Accra, Ghana; Department of Nuclear Safety and Security, School of Nuclear and Allied Sciences, University of Ghana, Atomic Campus, Accra, Legon, Ghana.
| | - Cyril Schandorf
- Department of Nuclear Safety and Security, School of Nuclear and Allied Sciences, University of Ghana, Atomic Campus, Accra, Legon, Ghana
| | - Stephen Inkoom
- Medical Physics Department, School of Nuclear and Allied Sciences, University of Ghana, Atomic Campus, Accra, Ghana; Radiation Protection Institute (RPI), Ghana Atomic Energy Commission, Accra, Ghana
| | - Augustine Faanu
- Radiological and Non-ionizing Radiation Directorate, Nuclear Regulatory Authority, Accra, Ghana
| | - Linn Rolstadaas
- Clinic of Radiology and Nuclear Medicine, St. Olavs University Hospital, Trondheim, Norway
| | - Pål Erik Goa
- Clinic of Radiology and Nuclear Medicine, St. Olavs University Hospital, Trondheim, Norway; Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
28
|
|