Kalidindi Y, Ganapathy AK, Cunningham L, Lovato A, Albers B, Shetty AS, Ballard DH. Customization of Computed Tomography Radio-Opacity in 3D-Printed Contrast-Injectable Tumor Phantoms. MICROMACHINES 2024; 15:992. [PMID: 39203643 PMCID: PMC11356228 DOI: 10.3390/mi15080992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2024] [Revised: 07/27/2024] [Accepted: 07/29/2024] [Indexed: 09/03/2024]
Abstract
Medical Imaging Phantoms (MIPs) calibrate imaging devices, train medical professionals, and can help procedural planning. Traditional MIPs are costly and limited in customization. Additive manufacturing allows for customizable, patient-specific phantoms. This study examines the CT attenuation characteristics of contrast-injectable, chambered 3D-printed phantoms to optimize tissue-mimicking capabilities. A MIP was constructed from a CT of a complex pelvic tumor near the iliac bifurcation. A 3D reconstruction of these structures composed of three chambers (aorta, inferior vena cava, tumor) with ports for contrast injection was 3D printed. Desired attenuations were 200 HU (arterial I), 150 HU (venous I), 40 HU (tumor I), 150 HU (arterial II), 90 HU (venous II), and 400 HU (tumor II). Solutions of Optiray 350 and water were injected, and the phantom was scanned on CT. Attenuations were measured using ROIs. Mean attenuation for the six phases was as follows: 37.49 HU for tumor I, 200.50 HU for venous I, 227.92 HU for arterial I, 326.20 HU for tumor II, 91.32 HU for venous II, and 132.08 HU for arterial II. Although the percent differences between observed and goal attenuation were high, the observed relative HU differences between phases were similar to goal HU differences. The observed attenuations reflected the relative concentrations of contrast solutions used, exhibiting a strong positive correlation with contrast concentration. The contrast-injectable tumor phantom exhibited a useful physiologic range of attenuation values, enabling the modification of tissue-mimicking 3D-printed phantoms even after the manufacturing process.
Collapse
Affiliation(s)
- Yuktesh Kalidindi
- School of Medicine, Saint Louis University, St. Louis, MO 63104, USA;
| | | | - Liam Cunningham
- School of Medicine, Washington University in St. Louis, St. Louis, MO 63110, USA; (A.K.G.); (L.C.)
| | - Adriene Lovato
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA; (A.L.); (A.S.S.)
| | - Brian Albers
- St. Louis Children’s Hospital Medical 3D Printing Center, BJC HealthCare, St. Louis, MO 63110, USA;
| | - Anup S. Shetty
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA; (A.L.); (A.S.S.)
| | - David H. Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA; (A.L.); (A.S.S.)
| |
Collapse
|
2
|
Bellmann Q, Peng Y, Genske U, Yan L, Wagner M, Jahnke P. Low-contrast lesion detection in neck CT: a multireader study comparing deep learning, iterative, and filtered back projection reconstructions using realistic phantoms. Eur Radiol Exp 2024; 8:84. [PMID: 39046565 PMCID: PMC11269546 DOI: 10.1186/s41747-024-00486-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Accepted: 06/18/2024] [Indexed: 07/25/2024] Open
Abstract
BACKGROUND Computed tomography (CT) reconstruction algorithms can improve image quality, especially deep learning reconstruction (DLR). We compared DLR, iterative reconstruction (IR), and filtered back projection (FBP) for lesion detection in neck CT. METHODS Nine patient-mimicking neck phantoms were examined with a 320-slice scanner at six doses: 0.5, 1, 1.6, 2.1, 3.1, and 5.2 mGy. Each of eight phantoms contained one circular lesion (diameter 1 cm; contrast -30 HU to the background) in the parapharyngeal space; one phantom had no lesions. Reconstruction was made using FBP, IR, and DLR. Thirteen readers were tasked with identifying and localizing lesions in 32 images with a lesion and 20 without lesions for each dose and reconstruction algorithm. Receiver operating characteristic (ROC) and localization ROC (LROC) analysis were performed. RESULTS DLR improved lesion detection with ROC area under the curve (AUC) 0.724 ± 0.023 (mean ± standard error of the mean) using DLR versus 0.696 ± 0.021 using IR (p = 0.037) and 0.671 ± 0.023 using FBP (p < 0.001). Likewise, DLR improved lesion localization, with LROC AUC 0.407 ± 0.039 versus 0.338 ± 0.041 using IR (p = 0.002) and 0.313 ± 0.044 using FBP (p < 0.001). Dose reduction to 0.5 mGy compromised lesion detection in FBP-reconstructed images compared to doses ≥ 2.1 mGy (p ≤ 0.024), while no effect was observed with DLR or IR (p ≥ 0.058). CONCLUSION DLR improved the detectability of lesions in neck CT imaging. Dose reduction to 0.5 mGy maintained lesion detectability when denoising reconstruction was used. RELEVANCE STATEMENT Deep learning enhances lesion detection in neck CT imaging compared to iterative reconstruction and filtered back projection, offering improved diagnostic performance and potential for x-ray dose reduction. KEY POINTS Low-contrast lesion detectability was assessed in anatomically realistic neck CT phantoms. Deep learning reconstruction (DLR) outperformed filtered back projection and iterative reconstruction. Dose has little impact on lesion detectability against anatomical background structures.
Collapse
Affiliation(s)
- Quirin Bellmann
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117, Berlin, Germany
| | - Yang Peng
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117, Berlin, Germany
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, 430030, Hubei Province, China
| | - Ulrich Genske
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117, Berlin, Germany
| | - Li Yan
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117, Berlin, Germany
| | - Moritz Wagner
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117, Berlin, Germany
| | - Paul Jahnke
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117, Berlin, Germany.
- Berlin Institute of Health (BIH), Anna-Louisa-Karsch-Str. 2, 10178, Berlin, Germany.
| |
Collapse
|
3
|
Shapira N, Donovan K, Mei K, Geagan M, Roshkovan L, Gang GJ, Abed M, Linna NB, Cranston CP, O'Leary CN, Dhanaliwala AH, Kontos D, Litt HI, Stayman JW, Shinohara RT, Noël PB. Three-dimensional printing of patient-specific computed tomography lung phantoms: a reader study. PNAS NEXUS 2023; 2:pgad026. [PMID: 36909822 PMCID: PMC9992761 DOI: 10.1093/pnasnexus/pgad026] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 12/20/2022] [Accepted: 01/17/2023] [Indexed: 02/04/2023]
Abstract
In modern clinical decision-support algorithms, heterogeneity in image characteristics due to variations in imaging systems and protocols hinders the development of reproducible quantitative measures including for feature extraction pipelines. With the help of a reader study, we investigate the ability to provide consistent ground-truth targets by using patient-specific 3D-printed lung phantoms. PixelPrint was developed for 3D-printing lifelike computed tomography (CT) lung phantoms by directly translating clinical images into printer instructions that control density on a voxel-by-voxel basis. Data sets of three COVID-19 patients served as input for 3D-printing lung phantoms. Five radiologists rated patient and phantom images for imaging characteristics and diagnostic confidence in a blinded reader study. Effect sizes of evaluating phantom as opposed to patient images were assessed using linear mixed models. Finally, PixelPrint's production reproducibility was evaluated. Images of patients and phantoms had little variation in the estimated mean (0.03-0.29, using a 1-5 scale). When comparing phantom images to patient images, effect size analysis revealed that the difference was within one-third of the inter- and intrareader variabilities. High correspondence between the four phantoms created using the same patient images was demonstrated by PixelPrint's production repeatability tests, with greater similarity scores between high-dose acquisitions of the phantoms than between clinical-dose acquisitions of a single phantom. We demonstrated PixelPrint's ability to produce lifelike CT lung phantoms reliably. These phantoms have the potential to provide ground-truth targets for validating the generalizability of inference-based decision-support algorithms between different health centers and imaging protocols and for optimizing examination protocols with realistic patient-based phantoms. Classification: CT lung phantoms, reader study.
Collapse
Affiliation(s)
- Nadav Shapira
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Kevin Donovan
- Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 423 Guardian Drive, Philadelphia, PA 19104, USA
| | - Kai Mei
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Michael Geagan
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Leonid Roshkovan
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Grace J Gang
- Department of Biomedical Engineering, Johns Hopkins University, 720 Rutland Avenue, Baltimore, MD 21205, USA
| | - Mohammed Abed
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
- Department of Radiology, College of Medicine, Ibn Sina University of Medical and Pharmaceutical Sciences, 79G3+3RR Qadisaya Expy, Baghdad, Iraq
| | - Nathaniel B Linna
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Coulter P Cranston
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Cathal N O'Leary
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Ali H Dhanaliwala
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Despina Kontos
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - Harold I Litt
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
| | - J Webster Stayman
- Department of Biomedical Engineering, Johns Hopkins University, 720 Rutland Avenue, Baltimore, MD 21205, USA
| | - Russell T Shinohara
- Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, 423 Guardian Drive, Philadelphia, PA 19104, USA
- Center for Biomedical Image Computing and Analytics (CBICA), Perelman School of Medicine of the University of Pennsylvania, 3700 Hamilton Walk, Philadelphia, PA 19104, USA
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Civic Center, Philadelphia, PA 19104, USA
- Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, Arcisstraße 21, 80333 München, Germany
| |
Collapse
|
4
|
Jusufbegović M, Pandžić A, Busuladžić M, Čiva LM, Gazibegović-Busuladžić A, Šehić A, Vegar-Zubović S, Jašić R, Beganović A. Utilisation of 3D Printing in the Manufacturing of an Anthropomorphic Paediatric Head Phantom for the Optimisation of Scanning Parameters in CT. Diagnostics (Basel) 2023; 13:328. [PMID: 36673137 PMCID: PMC9858362 DOI: 10.3390/diagnostics13020328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 11/27/2022] [Accepted: 11/29/2022] [Indexed: 01/18/2023] Open
Abstract
Computed tomography (CT) is a diagnostic imaging process that uses ionising radiation to obtain information about the interior anatomic structure of the human body. Considering that the medical use of ionising radiation implies exposing patients to radiation that may lead to unwanted stochastic effects and that those effects are less probable at lower doses, optimising imaging protocols is of great importance. In this paper, we used an assembled 3D-printed infant head phantom and matched its image quality parameters with those obtained for a commercially available adult head phantom using the imaging protocol dedicated for adult patients. In accordance with the results, an optimised scanning protocol was designed which resulted in dose reductions for paediatric patients while keeping image quality at an adequate level.
Collapse
Affiliation(s)
- Merim Jusufbegović
- Radiology Clinic, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina
- Department of Radiological Technologies, Faculty of Health Studies, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
| | - Adi Pandžić
- Department of Mechanical Production Engineering, Faculty of Mechanical Engineering Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
| | - Mustafa Busuladžić
- Faculty of Medicine, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
| | - Lejla M. Čiva
- Sarajevo Medical School, University Sarajevo School of Science and Technology, 71210 Ilidža, Bosnia and Herzegovina
| | | | - Adnan Šehić
- Department of Radiological Technologies, Faculty of Health Studies, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
| | - Sandra Vegar-Zubović
- Radiology Clinic, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina
- Faculty of Medicine, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
| | - Rahima Jašić
- Department of Radiation Protection and Medical Physics, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina
| | - Adnan Beganović
- Faculty of Science, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina
- Department of Radiation Protection and Medical Physics, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina
| |
Collapse
|
5
|
Genske U, Jahnke P. Human Observer Net: A Platform Tool for Human Observer Studies of Image Data. Radiology 2022; 303:524-530. [PMID: 35258375 DOI: 10.1148/radiol.211832] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Current software applications for human observer studies of images lack flexibility in study design, platform independence, multicenter use, and assessment methods and are not open source, limiting accessibility and expandability. Purpose To develop a user-friendly software platform that enables efficient human observer studies in medical imaging with flexibility of study design. Materials and Methods Software for human observer imaging studies was designed as an open-source web application to facilitate access, platform-independent usability, and multicenter studies. Different interfaces for study creation, participation, and management of results were implemented. The software was evaluated in human observer experiments between May 2019 and March 2021, in which duration of observer responses was tracked. Fourteen radiologists evaluated and graded software usability using the 100-point system usability scale. The application was tested in Chrome, Firefox, Safari, and Edge browsers. Results Software function was designed to allow visual grading analysis (VGA), multiple-alternative forced-choice (m-AFC), receiver operating characteristic (ROC), localization ROC, free-response ROC, and customized designs. The mean duration of reader responses per image or per image set was 6.2 seconds ± 4.8 (standard deviation), 5.8 seconds ± 4.7, 8.7 seconds ± 5.7, and 6.0 seconds ± 4.5 in four-AFC with 160 image quartets per reader, four-AFC with 640 image quartets per reader, localization ROC, and experimental studies, respectively. The mean system usability scale score was 83 ± 11 (out of 100). The documented code and a demonstration of the application are available online (https://github.com/genskeu/HON, https://hondemo.pythonanywhere.com/). Conclusion A user-friendly and efficient open-source application was developed for human reader experiments that enables study design versatility, as well as platform-independent and multicenter usability. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Thompson in this issue.
Collapse
Affiliation(s)
- Ulrich Genske
- From the Department of Radiology, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany (U.G., P.J.); Data Analytics and Computational Statistics, Hasso Plattner Institute, Digital Engineering Faculty, University of Potsdam, Potsdam, Germany (U.G.); and Berlin Institute of Health, Berlin, Germany (P.J.)
| | - Paul Jahnke
- From the Department of Radiology, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany (U.G., P.J.); Data Analytics and Computational Statistics, Hasso Plattner Institute, Digital Engineering Faculty, University of Potsdam, Potsdam, Germany (U.G.); and Berlin Institute of Health, Berlin, Germany (P.J.)
| |
Collapse
|
6
|
Rynio P, Wojtuń M, Wójcik Ł, Kawa M, Falkowski A, Gutowski P, Kazimierczak A. The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis. Quant Imaging Med Surg 2022; 12:1385-1396. [PMID: 35111632 DOI: 10.21037/qims-21-529] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 10/13/2021] [Indexed: 12/21/2022]
Abstract
Background Advances in 3D printing technology allow us to continually find new medical applications. One of them is 3D printing of aortic templates to guide vascular surgeons or interventional radiologists to create fenestrations in the stent-graft surface for the implantation procedure called fenestrated endovascular aortic aneurysm repair. It is believed that the use of 3D printing significantly improves the quality of modified fenestrated stent-grafts. However, the accuracy and reliability of personalized 3D printed models of aortic templates are not well established. Methods Thirteen 3D printed templates of the visceral aorta and sixteen of the aortic arch and their corresponding computer tomography of angiography images were included in this accuracy study. The 3D models were scanned in the same conditions on computed tomography (CT) and evaluated by three physicians experienced in vascular CT assessment. Model and patient CT measurements were performed at key landmarks to maintain quality for stent-graft modification, including side branches and aortic diameters. CT-scanned aortic templates were segmented, aligned with sourced patient data, and evaluated for the Hausdorff matrix. Next, Bland-Altman plots determined the degree of agreement. Results The Intraclass Correlation Coefficients values were more than 0.9 for all measurements of aortic diameters and aortic branches diameter in all landmark locations. Therefore, the reliability of the aortic templates was considered excellent. The Bland-Altman plots analysis indicated measurement biases of 0.05 to 0.47 for aortic arch templates and 0.06 to 0.38 for reno-visceral aortic templates. The arithmetic mean of Hausdorff's mean distances of the aortic arch templates was 0.47 mm (SD =0.06) and ranged from 0.34 to 0.58. The mean metrics for abdominal models was 0.24 mm (SD =0.03) and ranged from 0.21 to 0.31. Conclusions The printed models of 3D aortic templates are accurate and reliable, thus can be widely used in endovascular surgery and interventional radiology departments as aortic templates to guide the physician-modified fenestrated stent-graft fabrication.
Collapse
Affiliation(s)
- Pawel Rynio
- Department of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Maciej Wojtuń
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Łukasz Wójcik
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Miłosz Kawa
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Aleksander Falkowski
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Piotr Gutowski
- Department of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Arkadiusz Kazimierczak
- Department of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland
| |
Collapse
|
7
|
Shapira N, Donovan K, Mei K, Geagan M, Roshkovan L, Litt HI, Gang GJ, Stayman JW, Shinohara RT, Noël PB. PixelPrint: Three-dimensional printing of realistic patient-specific lung phantoms for CT imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2022; 12031:120310N. [PMID: 35664728 PMCID: PMC9164709 DOI: 10.1117/12.2611805] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Phantoms are essential tools for assessing and verifying performance in computed tomography (CT). Realistic patient-based lung phantoms that accurately represent textures and densities are essential in developing and evaluating novel CT hardware and software. This study introduces PixelPrint, a 3D-printing solution to create patient-specific lung phantoms with accurate contrast and textures. PixelPrint converts patient images directly into printer instructions, where density is modeled as the ratio of filament to voxel volume to emulate local attenuation values. For evaluation of PixelPrint, phantoms based on four COVID-19 pneumonia patients were manufactured and scanned with the original (clinical) CT scanners and protocols. Density and geometrical accuracies between phantom and patient images were evaluated for various anatomical features in the lung, and a radiomic feature comparison was performed for mild, moderate, and severe COVID-19 pneumonia patient-based phantoms. Qualitatively, CT images of the patient-based phantoms closely resemble the original CT images, both in texture and contrast levels, with clearly visible vascular and parenchymal structures. Regions-of-interest (ROIs) comparing attenuation demonstrated differences below 15 HU. Manual size measurements performed by an experienced thoracic radiologist revealed a high degree of geometrical correlation between identical patient and phantom features, with differences smaller than the intrinsic spatial resolution of the images. Radiomic feature analysis revealed high correspondence, with correlations of 0.95-0.99 between patient and phantom images. Our study demonstrates the feasibility of 3D-printed patient-based lung phantoms with accurate geometry, texture, and contrast that will enable protocol optimization, CT research and development advancements, and generation of ground-truth datasets for radiomic evaluations.
Collapse
Affiliation(s)
- Nadav Shapira
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Kevin Donovan
- Department of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, Philadelphia, PA, USA
| | - Kai Mei
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Michael Geagan
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Leonid Roshkovan
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Harold I. Litt
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Grace J. Gang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - J. Webster Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Russell T. Shinohara
- Department of Biostatistics, Epidemiology and Informatics, University of Pennsylvania, Philadelphia, PA, USA
| | - Peter B. Noël
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| |
Collapse
|
8
|
Mei K, Geagan M, Roshkovan L, Litt HI, Gang GJ, Shapira N, Stayman JW, Noël PB. Three-dimensional printing of patient-specific lung phantoms for CT imaging: Emulating lung tissue with accurate attenuation profiles and textures. Med Phys 2021; 49:825-835. [PMID: 34910309 DOI: 10.1002/mp.15407] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 11/22/2021] [Accepted: 11/22/2021] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Phantoms are a basic tool for assessing and verifying performance in CT research and clinical practice. Patient-based realistic lung phantoms accurately representing textures and densities are essential in developing and evaluating novel CT hardware and software. This study introduces PixelPrint, a 3D printing solution to create patient-based lung phantoms with accurate attenuation profiles and textures. METHODS PixelPrint, a software tool, was developed to convert patient digital imaging and communications in medicine (DICOM) images directly into FDM printer instructions (G-code). Density was modeled as the ratio of filament to voxel volume to emulate attenuation profiles for each voxel, with the filament ratio controlled through continuous modification of the printing speed. A calibration phantom was designed to determine the mapping between filament line width and Hounsfield units (HU) within the range of human lungs. For evaluation of PixelPrint, a phantom based on a single human lung slice was manufactured and scanned with the same CT scanner and protocol used for the patient scan. Density and geometrical accuracy between phantom and patient CT data were evaluated for various anatomical features in the lung. RESULTS For the calibration phantom, measured mean HU show a very high level of linear correlation with respect to the utilized filament line widths, (r > 0.999). Qualitatively, the CT image of the patient-based phantom closely resembles the original CT image both in texture and contrast levels (from -800 to 0 HU), with clearly visible vascular and parenchymal structures. Regions of interest comparing attenuation illustrated differences below 15 HU. Manual size measurements performed by an experienced thoracic radiologist reveal a high degree of geometrical correlation of details between identical patient and phantom features, with differences smaller than the intrinsic spatial resolution of the scans. CONCLUSION The present study demonstrates the feasibility of 3D-printed patient-based lung phantoms with accurate organ geometry, image texture, and attenuation profiles. PixelPrint will enable applications in the research and development of CT technology, including further development in radiomics.
Collapse
Affiliation(s)
- Kai Mei
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Michael Geagan
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Leonid Roshkovan
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Harold I Litt
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Grace J Gang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| | - Nadav Shapira
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - J Webster Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany
| |
Collapse
|
9
|
Comparison of low-contrast detectability between uniform and anatomically realistic phantoms-influences on CT image quality assessment. Eur Radiol 2021; 32:1267-1275. [PMID: 34476563 PMCID: PMC8794946 DOI: 10.1007/s00330-021-08248-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 07/22/2021] [Accepted: 08/05/2021] [Indexed: 11/21/2022]
Abstract
Objectives To evaluate the effects of anatomical phantom structure on task-based image quality assessment compared with a uniform phantom background. Methods Two neck phantom types of identical shape were investigated: a uniform type containing 10-mm lesions with 4, 9, 18, 30, and 38 HU contrast to the surrounding area and an anatomically realistic type containing lesions of the same size and location with 10, 18, 30, and 38 HU contrast. Phantom images were acquired at two dose levels (CTDIvol of 1.4 and 5.6 mGy) and reconstructed using filtered back projection (FBP) and adaptive iterative dose reduction 3D (AIDR 3D). Detection accuracy was evaluated by seven radiologists in a 4-alternative forced choice experiment. Results Anatomical phantom structure impaired lesion detection at all lesion contrasts (p < 0.01). Detectability in the anatomical phantom at 30 HU contrast was similar to 9 HU contrast in uniform images (91.1% vs. 89.5%). Detection accuracy decreased from 83.6% at 5.6 mGy to 55.4% at 1.4 mGy in uniform FBP images (p < 0.001), whereas AIDR 3D preserved detectability at 1.4 mGy (80.7% vs. 85% at 5.6 mGy, p = 0.375) and was superior to FBP (p < 0.001). In the assessment of anatomical images, superiority of AIDR 3D was not confirmed and dose reduction moderately affected detectability (74.6% vs. 68.2%, p = 0.027 for FBP and 81.1% vs. 73%, p = 0.018 for AIDR 3D). Conclusions A lesion contrast increase from 9 to 30 HU is necessary for similar detectability in anatomical and uniform neck phantom images. Anatomical phantom structure influences task-based assessment of iterative reconstruction and dose effects. Key Points • A lesion contrast increase from 9 to 30 HU is necessary for similar low-contrast detectability in anatomical and uniform neck phantom images. • Phantom background structure influences task-based assessment of iterative reconstruction and dose effects. • Transferability of CT assessment to clinical imaging can be expected to improve as the realism of the test environment increases. Supplementary Information The online version contains supplementary material available at 10.1007/s00330-021-08248-3.
Collapse
|
10
|
Mahmood U, Apte A, Kanan C, Bates DDB, Corrias G, Manneli L, Oh JH, Erdi YE, Nguyen J, O'Deasy J, Shukla-Dave A. Quality control of radiomic features using 3D-printed CT phantoms. J Med Imaging (Bellingham) 2021; 8:033505. [PMID: 34222557 PMCID: PMC8240751 DOI: 10.1117/1.jmi.8.3.033505] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 06/04/2021] [Indexed: 01/01/2023] Open
Abstract
Purpose: The lack of standardization in quantitative radiomic measures of tumors seen on computed tomography (CT) scans is generally recognized as an unresolved issue. To develop reliable clinical applications, radiomics must be robust across different CT scan modes, protocols, software, and systems. We demonstrate how custom-designed phantoms, imprinted with human-derived patterns, can provide a straightforward approach to validating longitudinally stable radiomic signature values in a clinical setting. Approach: Described herein is a prototype process to design an anatomically informed 3D-printed radiomic phantom. We used a multimaterial, ultra-high-resolution 3D printer with voxel printing capabilities. Multiple tissue regions of interest (ROIs), from four pancreas tumors, one lung tumor, and a liver background, were extracted from digital imaging and communication in medicine (DICOM) CT exam files and were merged together to develop a multipurpose, circular radiomic phantom (18 cm diameter and 4 cm width). The phantom was scanned 30 times using standard clinical CT protocols to test repeatability. Features that have been found to be prognostic for various diseases were then investigated for their repeatability and reproducibility across different CT scan modes. Results: The structural similarity index between the segment used from the patients' DICOM image and the phantom CT scan was 0.71. The coefficient variation for all assessed radiomic features was < 1.0 % across 30 repeat scans of the phantom. The percent deviation (pDV) from the baseline value, which was the mean feature value determined from repeat scans, increased with the application of the lung convolution kernel, changes to the voxel size, and increases in the image noise. Gray level co-occurrence features, contrast, dissimilarity, and entropy were particularly affected by different scan modes, presenting with pDV > ± 15 % . Conclusions: Previously discovered prognostic and popular radiomic features are variable in practice and need to be interpreted with caution or excluded from clinical implementation. Voxel-based 3D printing can reproduce tissue morphology seen on CT exams. We believe that this is a flexible, yet practical, way to design custom phantoms to validate and compare radiomic metrics longitudinally, over time, and across systems.
Collapse
Affiliation(s)
- Usman Mahmood
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, United States
| | - Aditya Apte
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, United States
| | - Christopher Kanan
- Rochester Institute of Technology, Department of Imaging Science, Rochester, New York, United States
| | - David D B Bates
- Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, United States
| | - Giuseppe Corrias
- Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, United States
| | | | - Jung Hun Oh
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, United States
| | - Yusuf Emre Erdi
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, United States
| | | | - Joseph O'Deasy
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, United States
| | - Amita Shukla-Dave
- Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York, United States.,Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, United States
| |
Collapse
|
11
|
Task-based assessment of neck CT protocols using patient-mimicking phantoms-effects of protocol parameters on dose and diagnostic performance. Eur Radiol 2020; 31:3177-3186. [PMID: 33151393 PMCID: PMC8043932 DOI: 10.1007/s00330-020-07374-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 08/18/2020] [Accepted: 10/05/2020] [Indexed: 11/25/2022]
Abstract
Objectives To assess how modifying multiple protocol parameters affects the dose and diagnostic performance of a neck CT protocol using patient-mimicking phantoms and task-based methods. Methods Six patient-mimicking neck phantoms containing hypodense lesions of 1 cm diameter and 30 HU contrast and one non-lesion phantom were examined with 36 CT protocols. All possible combinations of the following parameters were investigated: 100- and 120-kVp tube voltage; tube current modulation (TCM) noise levels of SD 7.5, 10, and 14; pitches of 0.637, 0.813, and 1.388; filtered back projection (FBP); and iterative reconstruction (AIDR 3D). Dose-length products (DLPs) and lesion detectability (assessed by 14 radiologists) were compared with the clinical standard protocol (120 kVp, TCM SD 7.5, 0.813 pitch, AIDR 3D). Results The DLP of the standard protocol was 25 mGy•cm; the area under the curve (AUC) was 0.839 (95%CI: 0.790–0.888). Combined effects of tube voltage reduction to 100 kVp and TCM noise level increase to SD 10 optimized protocol performance by improving dose (7.3 mGy•cm) and detectability (AUC 0.884, 95%CI: 0.844–0.924). Diagnostic performance was significantly affected by the TCM noise level at 120 kVp (AUC 0.821 at TCM SD 7.5 vs. 0.776 at TCM SD 14, p = 0.003), but not at 100-kVp tube voltage (AUC 0.839 at TCM SD 7.5 vs. 0.819 at TCM SD 14, p = 0.354), the reconstruction method at 100 kVp (AUC 0.854 for AIDR 3D vs. 0.806 for FBP, p < 0.001), but not at 120-kVp tube voltage (AUC 0.795 for AIDR 3D vs. 0.793 for FBP, p = 0.822), and the tube voltage for AIDR 3D reconstruction (p < 0.001), but not for FBP (p = 0.226). Conclusions Combined effects of 100-kVp tube voltage, TCM noise level of SD 10, a pitch of 0.813, and AIDR 3D resulted in an optimal neck protocol in terms of dose and diagnostic performance. Protocol parameters were subject to complex interactions, which created opportunities for protocol improvement. Key Points • A task-based approach using patient-mimicking phantoms was employed to optimize a CT system for neck imaging through systematic testing of protocol parameters. • Combined effects of 100-kVp tube voltage, TCM noise level of SD 10, a pitch of 0.813, and AIDR 3D reconstruction resulted in an optimal protocol in terms of dose and diagnostic performance. • Interactions of protocol parameters affect diagnostic performance and should be considered when optimizing CT techniques. Electronic supplementary material The online version of this article (10.1007/s00330-020-07374-8) contains supplementary material, which is available to authorized users.
Collapse
|
12
|
Shah D, Naik L, Paunipagar B, Rasalkar D, Chaudhary K, Bagaria V. Setting Up 3D Printing Services for Orthopaedic Applications: A Step-by-Step Guide and an Overview of 3DBioSphere. Indian J Orthop 2020; 54:217-227. [PMID: 33194095 PMCID: PMC7609604 DOI: 10.1007/s43465-020-00254-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 09/03/2020] [Indexed: 02/04/2023]
Abstract
INTRODUCTION 3D printing has widespread applications in orthopaedics including creating biomodels, patient-specific instruments, implants, and developing bioprints. 3DGraphy or printing 3D models enable the surgeon to understand, plan, and simulate different procedures on it. Despite widespread applications in non-healthcare specialties, it has failed to gain traction in healthcare settings. This is perhaps due to perceived capital expenditure cost and the lack of knowledge and skill required to execute the process. PURPOSE This article is written with an aim to provide step-by-step instructions for setting up a cost-efficient 3D printing laboratory in an institution or standalone radiology centre. The article with the help of video modules will explain the key process of segmentation, especially the technique of edge detection and thresholding which are the heart of 3D printing. CONCLUSION This is likely to enable the practising orthopaedician and radiologist to set up a 3D printing unit in their departments or even standalone radiology centres at minimal startup costs. This will enable maximal utilisation of this technology that is likely to bring about a paradigm shift in planning, simulation, and execution of complex surgeries.
Collapse
Affiliation(s)
- Darshil Shah
- grid.465035.1Department of Orthopaedics, Sir HN Reliance Foundation Hospital, Mumbai, India
| | - Lokesh Naik
- grid.465035.1Department of Orthopaedics, Sir HN Reliance Foundation Hospital, Mumbai, India
| | - Bhawan Paunipagar
- Department of Radiology, Akshay PET-CT, Akshay CT, Sai MRI Scans, Sangli, India ,Department of Radiology, Akshay CT and Sai MRI Scans, Sangli, Kolhapur India
| | - Darshana Rasalkar
- Department of Radiology, Akshay PET-CT, Akshay CT, Sai MRI Scans, Sangli, India ,Department of Radiology, Akshay CT and Sai MRI Scans, Sangli, Kolhapur India
| | - Kshitij Chaudhary
- grid.465035.1Department of Orthopaedics, Sir HN Reliance Foundation Hospital, Mumbai, India
| | - Vaibhav Bagaria
- grid.465035.1Department of Orthopaedics, Sir HN Reliance Foundation Hospital, Mumbai, India
| |
Collapse
|