1
|
Park EH, O'Donnell T, Fritz J. Dual-Energy Computed Tomography Applications in Rheumatology. Radiol Clin North Am 2024; 62:849-863. [PMID: 39059976 DOI: 10.1016/j.rcl.2024.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/28/2024]
Abstract
Dual-energy computed tomography (DECT) has emerged as a transformative tool in the past decade. Initially employed in gout within the field of rheumatology to distinguish and quantify monosodium urate crystals through its dual-material discrimination capability, DECT has since broadened its clinical applications. It now encompasses various rheumatic diseases, employing advanced techniques such as bone marrow edema assessment, iodine mapping, and collagen-specific imaging. This review article aims to examine the unique characteristics of DECT, discuss its strengths and limitations, illustrate its applications for accurately evaluating various rheumatic diseases in clinical practice, and propose future directions for DECT in rheumatology.
Collapse
Affiliation(s)
- Eun Hae Park
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, USA; Department of Radiology, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Geonjiro 20, Deokjin-gu, Jeonju, Jeollabukdo 54907, Republic of Korea
| | - Thomas O'Donnell
- CT Research Collaborations Siemens Healthineers, Malvern PA, USA
| | - Jan Fritz
- Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, USA.
| |
Collapse
|
2
|
Chen Y, Huang Z, Feng L, Zou W, Kong D, Zhu D, Dai G, Zhao W, Zhang Y, Luo M. Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography. Acad Radiol 2024; 31:3191-3199. [PMID: 38290889 DOI: 10.1016/j.acra.2024.01.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 01/11/2024] [Accepted: 01/11/2024] [Indexed: 02/01/2024]
Abstract
RATIONALE AND OBJECTIVES To evaluate the image quality of low-dose CT colonography (CTC) using deep learning-based reconstruction (DLR) compared to iterative reconstruction (IR). MATERIALS AND METHODS Adults included in the study were divided into four groups according to body mass index (BMI). Routine-dose (RD: 120 kVp) CTC images were reconstructed with IR (RD-IR); low-dose (LD: 100kVp) images were reconstructed with IR (LD-IR) and DLR (LD-DLR). The subjective image quality was rated on a 5-point scale by two radiologists independently. The parameters for objective image quality included noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The Friedman test was used to compare the image quality among RD-IR, LD-IR and LD-DLR. The KruskalWallis test was used to compare the results among different BMI groups. RESULTS A total of 270 volunteers (mean age: 47.94 years ± 11.57; 115 men) were included. The effective dose of low-dose CTC was decreased by approximately 83.18% (5.18mSv ± 0.86 vs. 0.86mSv ± 0.05, P < 0.001). The subjective image quality score of LD-DLR was superior to that of LD-IR (3.61 ± 0.56 vs. 2.70 ± 0.51, P < 0.001) and on par with the RD- IR's (3.61 ± 0.56 vs. 3.74 ± 0.52, P = 0.486). LD-DLR exhibited the lowest noise, and the maximum SNR and CNR compared to RD-IR and LD-IR (all P < 0.001). No statistical difference was found in the noise of LD-DLR images between different BMI groups (all P > 0.05). CONCLUSION Compared to IR, DLR provided low-dose CTC with superior image quality at an average radiation dose of 0.86mSv, which may be promising in future colorectal cancer screening.
Collapse
Affiliation(s)
- Yanshan Chen
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Department of Radiology, Jinling Hospital, the First School of Clinical Medicine, Southern Medical University, Nanjing, Jiangsu 210002, China (Y.C.)
| | - Zixuan Huang
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Department of Radiology, Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, Guangdong 510095, China (Z.H.)
| | - Lijuan Feng
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Department of Radiology, the First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi 530021, China (L.F.)
| | - Wenbin Zou
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.)
| | - Decan Kong
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.)
| | - Dongyun Zhu
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.)
| | - Guochao Dai
- Medical Imaging Center, the First People's Hospital of Kashi Area, Kashi, Xinjiang 844000, China (G.D.)
| | - Weidong Zhao
- Department of Radiology, the Second Hospital of Shanxi Medical University, Taiyuan, Shanxi 030001, China (W.Z.)
| | - Yuanke Zhang
- School of Computer Science, Qufu Normal University, Rizhao, Shandong 276826, China (Y.Z.)
| | - Mingyue Luo
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.).
| |
Collapse
|
3
|
Shin DJ, Choi YH, Lee SB, Cho YJ, Lee S, Cheon JE. Low-iodine-dose computed tomography coupled with an artificial intelligence-based contrast-boosting technique in children: a retrospective study on comparison with conventional-iodine-dose computed tomography. Pediatr Radiol 2024; 54:1315-1324. [PMID: 38839610 PMCID: PMC11254996 DOI: 10.1007/s00247-024-05953-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 05/12/2024] [Accepted: 05/13/2024] [Indexed: 06/07/2024]
Abstract
BACKGROUND Low-iodine-dose computed tomography (CT) protocols have emerged to mitigate the risks associated with contrast injection, often resulting in decreased image quality. OBJECTIVE To evaluate the image quality of low-iodine-dose CT combined with an artificial intelligence (AI)-based contrast-boosting technique in abdominal CT, compared to a standard-iodine-dose protocol in children. MATERIALS AND METHODS This single-center retrospective study included 35 pediatric patients (mean age 9.2 years, range 1-17 years) who underwent sequential abdominal CT scans-one with a standard-iodine-dose protocol (standard-dose group, Iobitridol 350 mgI/mL) and another with a low-iodine-dose protocol (low-dose group, Iohexol 240 mgI/mL)-within a 4-month interval from January 2022 to July 2022. The low-iodine CT protocol was reconstructed using an AI-based contrast-boosting technique (contrast-boosted group). Quantitative and qualitative parameters were measured in the three groups. For qualitative parameters, interobserver agreement was assessed using the intraclass correlation coefficient, and mean values were employed for subsequent analyses. For quantitative analysis of the three groups, repeated measures one-way analysis of variance with post hoc pairwise analysis was used. For qualitative analysis, the Friedman test followed by post hoc pairwise analysis was used. Paired t-tests were employed to compare radiation dose and iodine uptake between the standard- and low-dose groups. RESULTS The standard-dose group exhibited higher attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of organs and vessels compared to the low-dose group (all P-values < 0.05 except for liver SNR, P = 0.12). However, noise levels did not differ between the standard- and low-dose groups (P = 0.86). The contrast-boosted group had increased attenuation, CNR, and SNR of organs and vessels, and reduced noise compared with the low-dose group (all P < 0.05). The contrast-boosted group showed no differences in attenuation, CNR, and SNR of organs and vessels (all P > 0.05), and lower noise (P = 0.002), than the standard-dose group. In qualitative analysis, the contrast-boosted group did not differ regarding vessel enhancement and lesion conspicuity (P > 0.05) but had lower noise (P < 0.05) and higher organ enhancement and artifacts (all P < 0.05) than the standard-dose group. While iodine uptake was significantly reduced in low-iodine-dose CT (P < 0.001), there was no difference in radiation dose between standard- and low-iodine-dose CT (all P > 0.05). CONCLUSION Low-iodine-dose abdominal CT, combined with an AI-based contrast-boosting technique exhibited comparable organ and vessel enhancement, as well as lesion conspicuity compared to standard-iodine-dose CT in children. Moreover, image noise decreased in the contrast-boosted group, albeit with an increase in artifacts.
Collapse
Affiliation(s)
- Dong-Joo Shin
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
| | - Young Hun Choi
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, Jongno-Gu, Seoul, Republic of Korea.
| | - Seul Bi Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Jongno-Gu, Seoul, Republic of Korea
| | - Yeon Jin Cho
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Jongno-Gu, Seoul, Republic of Korea
| | - Seunghyun Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Jongno-Gu, Seoul, Republic of Korea
| | - Jung-Eun Cheon
- Department of Radiology, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Jongno-Gu, Seoul, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Jongno-Gu, Seoul, Republic of Korea
| |
Collapse
|
4
|
Choi HU, Cho J, Hwang J, Lee S, Chang W, Park JH, Lee KH. Diagnostic performance and image quality of an image-based denoising algorithm applied to radiation dose-reduced CT in diagnosing acute appendicitis. Abdom Radiol (NY) 2024; 49:1839-1849. [PMID: 38411690 PMCID: PMC11213764 DOI: 10.1007/s00261-024-04246-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 02/07/2024] [Accepted: 02/07/2024] [Indexed: 02/28/2024]
Abstract
PURPOSE To evaluate diagnostic performance and image quality of ultralow-dose CT (ULDCT) in diagnosing acute appendicitis with an image-based deep-learning denoising algorithm (IDLDA). METHODS This retrospective multicenter study included 180 patients (mean ± standard deviation, 29 ± 9 years; 91 female) who underwent contrast-enhanced 2-mSv CT for suspected appendicitis from February 2014 to August 2016. We simulated ULDCT from 2-mSv CT, reducing the dose by at least 50%. Then we applied an IDLDA on ULDCT to produce denoised ULDCT (D-ULDCT). Six radiologists with different experience levels (three board-certified radiologists and three residents) independently reviewed the ULDCT and D-ULDCT. They rated the likelihood of appendicitis and subjective image qualities (subjective image noise, diagnostic acceptability, and artificial sensation). One radiologist measured image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). We used the receiver operating characteristic (ROC) analyses, Wilcoxon's signed-rank tests, and paired t-tests. RESULTS The area under the ROC curves (AUC) for diagnosing appendicitis ranged 0.90-0.97 for ULDCT and 0.94-0.97 for D-ULDCT. The AUCs of two residents were significantly higher on D-ULDCT (AUC difference = 0.06 [95% confidence interval, 0.01-0.11; p = .022] and 0.05 [0.00-0.10; p = .046], respectively). D-ULDCT provided better subjective image noise and diagnostic acceptability to all six readers. However, the response of board-certified radiologists and residents differed in artificial sensation (all p ≤ .003). D-ULDCT showed significantly lower image noise, higher SNR, and higher CNR (all p < .001). CONCLUSION An IDLDA can provide better ULDCT image quality and enhance diagnostic performance for less-experienced radiologists.
Collapse
Affiliation(s)
- Hyeon Ui Choi
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
| | - Jungheum Cho
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea.
| | - Jinhee Hwang
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Korea
| | - Seungjae Lee
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
- Institute of Health and Environment, Seoul National University, Seoul, Korea
| | - Won Chang
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
| | - Ji Hoon Park
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
- Department of Medical Device Development, Seoul National University College of Medicine, Seoul, Korea
| | - Kyoung Ho Lee
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea
- Department of Medical Device Development, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
5
|
Gemmete JJ. Dual-Energy Computed Tomography in the Evaluation and Management of Subarachnoid Hemorrhage, Intracranial Hemorrhage, and Acute Ischemic Stroke. Neuroimaging Clin N Am 2024; 34:241-249. [PMID: 38604708 DOI: 10.1016/j.nic.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2024]
Abstract
Dual-energy computed tomography (DECT) has emerged as a valuable imaging modality in the diagnosis and management of various cerebrovascular pathologies, including subarachnoid hemorrhage, intracranial hemorrhage, and acute ischemic stroke. This article reviews the principles of DECT and its applications in the evaluation and management of these conditions. The authors discuss the advantages of DECT over conventional computed tomography, as well as its limitations, and provide an overview of current research and future directions in the field.
Collapse
Affiliation(s)
- Joseph J Gemmete
- Departments of Radiology, Neurosurgery, Neurology, and Otolaryngology, Michigan Medicine, UH B1D 328, 1500 E Medical Center Drive, Ann Arbor, MI 48019, USA.
| |
Collapse
|
6
|
Balogh ZA, Barna Z, Majoros E. Comparison of iterative reconstruction implementations for multislice helical CT. Z Med Phys 2024:S0939-3889(24)00046-1. [PMID: 38679541 DOI: 10.1016/j.zemedi.2024.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 02/20/2024] [Accepted: 04/03/2024] [Indexed: 05/01/2024]
Abstract
The most mature image reconstruction algorithms in multislice helical computed tomography are based on analytical and iterative methods. Over the past decades, several methods have been developed for iterative reconstructions that improve image quality by reducing noise and artifacts. In the regularization step of iterative reconstruction, noise can be significantly reduced, thereby making low-dose CT. The quality of the reconstructed image can be further improved by using model-based reconstructions. In these reconstructions, the main focus is on modeling the data acquisition process, including the behavior of the photon beams, the geometry of the system, etc. In this article, we propose two model-based reconstruction algorithms using a virtual detector for multislice helical CT. The aim of this study is to compare the effect of using a virtual detector on image quality for the two proposed algorithms with a model-based iterative reconstruction using the original detector model. Since the algorithms are implemented using multiple GPUs, the merging of separately reconstructed volumes can significantly affect image quality. This issue is often referred to as the "long object" problem, for which we also present a solution that plays an important role in the proposed reconstruction processes. The algorithms were evaluated using mathematical and physical phantoms, as well as patient cases. The SSIM, MS-SSIM and L1 metrics were utilized to evaluate the image quality of the mathematical phantom case. To demonstrate the effectiveness of the algorithms, we used the CatPhan 600 phantom. Additionally, anonymized patient scans were used to showcase the improvements in image quality on real scan data.
Collapse
Affiliation(s)
- Zsolt Adam Balogh
- Department of Mathematical Sciences, United Arab Emirates University, Al Ain P.O.Box: 15551, United Arab Emirates.
| | | | - Eva Majoros
- Marton Varga Technical College, Budapest H-1149, Hungary
| |
Collapse
|
7
|
Park H, Hwang EJ, Goo JM. Deep Learning-Based Kernel Adaptation Enhances Quantification of Emphysema on Low-Dose Chest CT for Predicting Long-Term Mortality. Invest Radiol 2024; 59:278-286. [PMID: 37428617 DOI: 10.1097/rli.0000000000001003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/12/2023]
Abstract
OBJECTIVES The aim of this study was to ascertain the predictive value of quantifying emphysema using low-dose computed tomography (LDCT) post deep learning-based kernel adaptation on long-term mortality. MATERIALS AND METHODS This retrospective study investigated LDCTs obtained from asymptomatic individuals aged 60 years or older during health checkups between February 2009 and December 2016. These LDCTs were reconstructed using a 1- or 1.25-mm slice thickness alongside high-frequency kernels. A deep learning algorithm, capable of generating CT images that resemble standard-dose and low-frequency kernel images, was applied to these LDCTs. To quantify emphysema, the lung volume percentage with an attenuation value less than or equal to -950 Hounsfield units (LAA-950) was gauged before and after kernel adaptation. Low-dose chest CTs with LAA-950 exceeding 6% were deemed emphysema-positive according to the Fleischner Society statement. Survival data were sourced from the National Registry Database at the close of 2021. The risk of nonaccidental death, excluding causes such as injury or poisoning, was explored according to the emphysema quantification results using multivariate Cox proportional hazards models. RESULTS The study comprised 5178 participants (mean age ± SD, 66 ± 3 years; 3110 males). The median LAA-950 (18.2% vs 2.6%) and the proportion of LDCTs with LAA-950 exceeding 6% (96.3% vs 39.3%) saw a significant decline after kernel adaptation. There was no association between emphysema quantification before kernel adaptation and the risk of nonaccidental death. Nevertheless, after kernel adaptation, higher LAA-950 (hazards ratio for 1% increase, 1.01; P = 0.045) and LAA-950 exceeding 6% (hazards ratio, 1.36; P = 0.008) emerged as independent predictors of nonaccidental death, upon adjusting for age, sex, and smoking status. CONCLUSIONS The application of deep learning for kernel adaptation proves instrumental in quantifying pulmonary emphysema on LDCTs, establishing itself as a potential predictive tool for long-term nonaccidental mortality in asymptomatic individuals.
Collapse
Affiliation(s)
- Hyungin Park
- From the Department of Radiology, Seoul National University Hospital, Seoul, South Korea (H.P., E.J.H., J.M.G.); and Department of Radiology, Seoul National University College of Medicine, Seoul, South Korea (J.M.G.)
| | | | | |
Collapse
|
8
|
Shu G, Zhao L, Li F, Jiang Y, Zhang X, Yu C, Pan J, Sun SK. Metallic artifacts-free spectral computed tomography angiography based on renal clearable bismuth chelate. Biomaterials 2024; 305:122422. [PMID: 38128318 DOI: 10.1016/j.biomaterials.2023.122422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/28/2023] [Accepted: 12/07/2023] [Indexed: 12/23/2023]
Abstract
Computed tomography angiography (CTA) is one of the most important diagnosis techniques for various vascular diseases in clinic. However, metallic artifacts caused by metal implants and calcified plaques in more and more patients severely hinder its wide applications. Herein, we propose an improved metallic artifacts-free spectral CTA technique based on renal clearable bismuth chelate (Bi-DTPA dimeglumine) for the first time. Bi-DTPA dimeglumine owns the merits of ultra-simple synthetic process, approximately 100% of yield, large-scale production capability, good biocompatibility, and favorable renal clearable ability. More importantly, Bi-DTPA dimeglumine shows superior contrast-enhanced effect in CTA compared with clinical iohexol at a wide range of X-ray energies especially in higher X-ray energy. In rabbits' model with metallic transplants, Bi-DTPA dimeglumine assisted-spectral CTA can not only effectively mitigate metallic artifacts by reducing beam hardening effect under high X-ray energy, but also enables accurate delineation of vascular structure. Our proposed strategy opens a revolutionary way to solve the bottleneck problem of metallic artifacts in CTA examinations.
Collapse
Affiliation(s)
- Gang Shu
- School of Medical Imaging, Tianjin Medical University, Tianjin, 300203, China; Department of Radiology, The Second Hospital of Tianjin Medical University, Tianjin, 300211, China
| | - Lu Zhao
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Fengtan Li
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Yingjian Jiang
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Xuening Zhang
- Department of Radiology, The Second Hospital of Tianjin Medical University, Tianjin, 300211, China
| | - Chunshui Yu
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Jinbin Pan
- Department of Radiology, Tianjin Key Laboratory of Functional Imaging, Tianjin Medical University General Hospital, Tianjin, 300052, China.
| | - Shao-Kai Sun
- School of Medical Imaging, Tianjin Medical University, Tianjin, 300203, China.
| |
Collapse
|
9
|
Kang Y, Hwang SH, Han K, Shin HJ. Comparison of image quality, contrast administration, and radiation doses in pediatric abdominal dual-layer detector dual-energy CT using propensity score matching analysis. Eur J Radiol 2023; 169:111177. [PMID: 37944333 DOI: 10.1016/j.ejrad.2023.111177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 10/25/2023] [Accepted: 10/27/2023] [Indexed: 11/12/2023]
Abstract
PURPOSE To compare the image quality, contrast administration, and radiation dose between single-energy CT (SECT) and dual-energy CT (DECT) in pediatric patients. METHODS From March to December 2021, children who underwent abdominal SECT or DECT were retrospectively included in this study. The DECT group received 10-30 % less contrast than the routine dose. CT images were obtained at hepatic venous phase using a routine reconstruction method (iDose4). DECT scans were additionally reconstructed with a virtual monoenergetic image (VMI) at 40 and 65 keV. Quantitative image evaluations compared the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the liver, portal vein, and pancreas. Qualitative analysis assessed degree of contrast enhancement, lesion or organ conspicuity, image noise, artificiality, and overall image quality. RESULTS Among 318 patients, 112 (median age, 16 years; 56 in each group) were included after propensity score matching. Compared with the SECT group, DECT group with iDose4 demonstrated lower CNRs and SNRs, while VMI at 40 or 65 keV showed no significant difference. In qualitative analysis, iDose4 produced higher scores on artificiality, and VMI at 40 keV demonstrated superior contrast enhancement and lesion conspicuity in the DECT group. Overall image quality was higher with VMI 65 keV among the DECT patients, and there was no significant difference compared to SECT. The volume CT dose index (CTDIvol) did not differ significantly between the two groups (median, 2.8 mGy vs. 2.9 mGy; p = 0.802). The injected contrast volume was reduced by 10 % in the DECT group. CONCLUSION Pediatric abdominal DECT with reduced contrast administration showed no significant differences in image quality and radiation dose compared to SECT.
Collapse
Affiliation(s)
- Yeseul Kang
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Yongin Severance Hospital 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do 16995, Republic of Korea
| | - Shin Hye Hwang
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Yongin Severance Hospital 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do 16995, Republic of Korea
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Severance Hospital, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Hyun Joo Shin
- Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Yongin Severance Hospital 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do 16995, Republic of Korea.
| |
Collapse
|
10
|
Shim J, Kim K, Lee Y. Effect of iodine concentration reduction by comparison of virtual monoenergetic image quality with dual-energy computed tomography. Appl Radiat Isot 2023; 200:110967. [PMID: 37527620 DOI: 10.1016/j.apradiso.2023.110967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 07/20/2023] [Accepted: 07/28/2023] [Indexed: 08/03/2023]
Abstract
This study aimed to evaluate the image quality of virtual monoenergetic images (VMIs) with tube voltage modulation in pediatric abdominal computed tomography (CT) examination and to determine the effect of decreasing contrast agent concentration. Using a 1-year old pediatric phantom, five contrast agent concentration diluent tubes of 100%, 80%, 60%, 40%, and 20% of the same concentration as the average Hounsfield unit (HU) in the descending aorta were inserted, and the mixed image and VMIs (40, 60, and 80 keV) acquired using dual-energy CT were compared with single-energy CT (SECT) images. For quantitative evaluation, the HU and coefficient of variation (COV) of each image were compared and analyzed. The analysis revealed that the HU of the 40 keV VMIs, acquired with a tube voltage of 70 kV and 100% contrast agent concentration, was 61% higher than that of the SECT image. The results showed that SECT had the lowest COV among all contrast agent concentration and tube voltage combinations, while the 40 keV image acquired at 70 kV had the second-lowest COV value. The HU of the 40 keV image acquired at 70 kV at a contrast agent concentration of 100% was 9% higher than that of SECT at 80% concentration. This study confirms that 40 keV VMIs are more useful than SECT images for vascular diagnosis with contrast in pediatric abdominal CT examinations and that a 20% reduction in contrast agent concentration can reduce the risk of contrast agent concentration-induced nephrotoxicity in pediatric patients by increasing the subjective acceptability of image quality for diagnosis.
Collapse
Affiliation(s)
- Jina Shim
- Department of Diagnostic Radiology, Severance Hospital, Seoul, Republic of Korea
| | - Kyuseok Kim
- Department of Radiological Science, Gachon University, Incheon, Republic of Korea.
| | - Youngjin Lee
- Department of Radiological Science, Gachon University, Incheon, Republic of Korea.
| |
Collapse
|
11
|
Ng CKC. Generative Adversarial Network (Generative Artificial Intelligence) in Pediatric Radiology: A Systematic Review. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1372. [PMID: 37628371 PMCID: PMC10453402 DOI: 10.3390/children10081372] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/07/2023] [Accepted: 08/09/2023] [Indexed: 08/27/2023]
Abstract
Generative artificial intelligence, especially with regard to the generative adversarial network (GAN), is an important research area in radiology as evidenced by a number of literature reviews on the role of GAN in radiology published in the last few years. However, no review article about GAN in pediatric radiology has been published yet. The purpose of this paper is to systematically review applications of GAN in pediatric radiology, their performances, and methods for their performance evaluation. Electronic databases were used for a literature search on 6 April 2023. Thirty-seven papers met the selection criteria and were included. This review reveals that the GAN can be applied to magnetic resonance imaging, X-ray, computed tomography, ultrasound and positron emission tomography for image translation, segmentation, reconstruction, quality assessment, synthesis and data augmentation, and disease diagnosis. About 80% of the included studies compared their GAN model performances with those of other approaches and indicated that their GAN models outperformed the others by 0.1-158.6%. However, these study findings should be used with caution because of a number of methodological weaknesses. For future GAN studies, more robust methods will be essential for addressing these issues. Otherwise, this would affect the clinical adoption of the GAN-based applications in pediatric radiology and the potential advantages of GAN could not be realized widely.
Collapse
Affiliation(s)
- Curtise K. C. Ng
- Curtin Medical School, Curtin University, GPO Box U1987, Perth, WA 6845, Australia; or ; Tel.: +61-8-9266-7314; Fax: +61-8-9266-2377
- Curtin Health Innovation Research Institute (CHIRI), Faculty of Health Sciences, Curtin University, GPO Box U1987, Perth, WA 6845, Australia
| |
Collapse
|
12
|
Zhong J, Shen H, Chen Y, Xia Y, Shi X, Lu W, Li J, Xing Y, Hu Y, Ge X, Ding D, Jiang Z, Yao W. Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT. J Digit Imaging 2023; 36:1390-1407. [PMID: 37071291 PMCID: PMC10406981 DOI: 10.1007/s10278-023-00806-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 04/19/2023] Open
Abstract
This study is aimed to evaluate effects of deep learning image reconstruction (DLIR) on image quality in single-energy CT (SECT) and dual-energy CT (DECT), in reference to adaptive statistical iterative reconstruction-V (ASIR-V). The Gammex 464 phantom was scanned in SECT and DECT modes at three dose levels (5, 10, and 20 mGy). Raw data were reconstructed using six algorithms: filtered back-projection (FBP), ASIR-V at 40% (AV-40) and 100% (AV-100) strength, and DLIR at low (DLIR-L), medium (DLIR-M), and high strength (DLIR-H), to generate SECT 120kVp images and DECT 120kVp-like images. Objective image quality metrics were computed, including noise power spectrum (NPS), task transfer function (TTF), and detectability index (d'). Subjective image quality evaluation, including image noise, texture, sharpness, overall quality, and low- and high-contrast detectability, was performed by six readers. DLIR-H reduced overall noise magnitudes from FBP by 55.2% in a more balanced way of low and high frequency ranges comparing to AV-40, and improved the TTF values at 50% for acrylic inserts by average percentages of 18.32%. Comparing to SECT 20 mGy AV-40 images, the DECT 10 mGy DLIR-H images showed 20.90% and 7.75% improvement in d' for the small-object high-contrast and large-object low-contrast tasks, respectively. Subjective evaluation showed higher image quality and better detectability. At 50% of the radiation dose level, DECT with DLIR-H yields a gain in objective detectability index compared to full-dose AV-40 SECT images used in daily practice.
Collapse
Affiliation(s)
- Jingyu Zhong
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Changning District, No. 1111 Xianxia Road, Shanghai, 200336 China
| | - Hailin Shen
- Department of Radiology, Suzhou Kowloon Hospital, Shanghai Jiao Tong University School of Medicine, Suzhou, 215028 China
| | - Yong Chen
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025 China
| | - Yihan Xia
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025 China
| | - Xiaomeng Shi
- Department of Materials, Imperial College London, South Kensington Campus, London, SW7 2AZ UK
| | - Wei Lu
- Computed Tomography Research Center, GE Healthcare, Shanghai, 201203 China
| | - Jianying Li
- Computed Tomography Research Center, GE Healthcare, Beijing, 100176 China
| | - Yue Xing
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Changning District, No. 1111 Xianxia Road, Shanghai, 200336 China
| | - Yangfan Hu
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Changning District, No. 1111 Xianxia Road, Shanghai, 200336 China
| | - Xiang Ge
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Changning District, No. 1111 Xianxia Road, Shanghai, 200336 China
| | - Defang Ding
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Changning District, No. 1111 Xianxia Road, Shanghai, 200336 China
| | - Zhenming Jiang
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Changning District, No. 1111 Xianxia Road, Shanghai, 200336 China
| | - Weiwu Yao
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Changning District, No. 1111 Xianxia Road, Shanghai, 200336 China
| |
Collapse
|
13
|
Dabli D, Durand Q, Frandon J, de Oliveira F, Pastor M, Beregi J, Greffier J. Impact of the automatic tube current modulation (ATCM) system on virtual monoenergetic image quality for dual-source CT: A phantom study. Phys Med 2023; 109:102574. [PMID: 37004360 DOI: 10.1016/j.ejmp.2023.102574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 02/23/2023] [Accepted: 03/22/2023] [Indexed: 04/03/2023] Open
Abstract
PURPOSE To assess the impact of the automatic tube current modulation (ATCM) on virtual monoenergetic images (VMIs) quality in dual-source CT(DSCT). MATERIALS AND METHODS Acquisitions were performed on DSCT using the Mercury phantom. The acquisition parameters for an abdomen-pelvic examination with single-energy CT(SECT) and dual-energy CT(DECT) imaging were used. Acquisitions were performed for each imaging mode using fixed mAs and ATCM. The mAs value was set to obtain a volume CT dose index of 11 mGy in fixed mAs acquisitions. This value was used as the reference mAs in ATCM acquisitions. The noise power spectrum and task-based transfer function at 40,50,60 and 70 keV levels were computed on VMIs and SECT images. The detectability index (d') was calculated for a lesion with an iodine concentration of 10 mg/mL. RESULTS The noise magnitude on VMIs was higher with the ATCM system than with fixed mAs for all energy levels and section diameters of 21,26 and 31 cm. The noise texture and spatial resolution were similar between the fixed mAs and ATCM acquisitions for both imaging modes. The d' values were lower for all energy levels with ATCM than with fixed mAs acquisitions for 21 and 26 cm diameters by -39.82 ± 9.32%, similar at 31 cm diameter -4.13 ± 0.24% and higher at 36 cm diameter 10.40 ± 6.69%. It was higher on VMIs at all energy levels compared to SECT images. CONCLUSIONS The ATCM system could be used with DECT imaging to optimize patient exposure without changing the noise texture and spatial resolution of VMIs compared to fixed mAs and SECT.
Collapse
|
14
|
Significant CT dose reduction of 2-[ 18F]FDG PET/CT in pretreatment pediatric lymphoma without compromising the diagnostic and staging efficacy. Eur Radiol 2023; 33:2248-2257. [PMID: 36166086 DOI: 10.1007/s00330-022-09145-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 08/29/2022] [Accepted: 09/05/2022] [Indexed: 11/04/2022]
Abstract
OBJECTIVES To compare the diagnostic and staging efficacy of PET/diagnostic-level CT (PET/DxCT) and PET/low-dose CT (PET/LDCT) in pretreatment pediatric lymphoma patients and to estimate the reduction of the CT effective dose in the PET/CT scan. METHODS One hundred and five pediatric patients who underwent total-body PET/CT examination were enrolled and divided into the DxCT group (n = 47) and LDCT group (n = 58) according to their dose levels. The sensitivity, specificity, PPV, and NPV of PET/DxCT and PET/LDCT for detecting the involvement of lymph node, spleen, bone marrow, and other extranodal organs in pretreatment lymphoma were compared. ROC analysis was performed to evaluate the integral efficiency. The staging accuracies based on PET/DxCT and PET/LDCT were also evaluated. Dosimetry was calculated for DxCT and LDCT, and the reduction in the effective dose was estimated. RESULTS In the diagnosis of nodal, splenic, bone marrow, and other extranodal involvement, the differences in sensitivity, specificity, PPV, and NPV between PET/LDCT and PET/DxCT were not significant (all p values ∈ [0.332, 1.000]). Both modalities had accuracies above 90% and the ROC analysis indicated good or high efficiency in diagnosing all patterns of lymphoma involvement. PET/LDCT and PET/DxCT each had a staging accuracy of 89.7% and 89.4%, respectively. LDCT had a comparable image quality score with DxCT, with a significant increase in noise (p < 0.001) and a 66.1% reduction in effective dose. CONCLUSIONS PET/LDCT allowed for a 66.1% CT effective dose reduction compared to PET/DxCT in pediatric lymphoma patients without compromising the diagnostic and staging efficacy. KEY POINTS • Pediatric lymphoma patients can benefit from a reduced effective dose of PET/CT. • This retrospective study showed that the diagnostic and staging efficacies of PET/low-dose CT are comparable to those of PET/diagnostic-level CT, both with satisfactory efficiency in diagnosing all patterns of lymphoma involvement. • PET/low-dose CT allowed for a 66.1% CT effective dose reduction compared to PET/diagnostic-level CT.
Collapse
|
15
|
Lee HJ, Kim JS, Lee JK, Lee HA, Pak S. Ultra-low-dose hepatic multiphase CT using deep learning-based image reconstruction algorithm focused on arterial phase in chronic liver disease: A non-inferiority study. Eur J Radiol 2023; 159:110659. [PMID: 36584563 DOI: 10.1016/j.ejrad.2022.110659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 12/07/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022]
Abstract
PURPOSE This study determined whether image quality and detectability of ultralow-dose hepatic multiphase CT (ULDCT, 33.3% dose) using a vendor-agnostic deep learning model(DLM) are noninferior to those of standard-dose CT (SDCT, 100% dose) using model-based iterative reconstruction(MBIR) in patients with chronic liver disease focusing on arterial phase. METHODS Sixty-seven patients underwent hepatic multiphase CT using a dual-source scanner to obtain two different radiation dose CT scans (100%, SDCT and 33.3%, ULDCT). ULDCT using DLM and SDCT using MBIR were compared. A margin of -0.5 for the difference between the two protocols was pre-defined as noninferiority of the overall image quality of the arterial phase image. Quantitative image analysis (signal to noise ratio[SNR] and contrast to noise ratio[CNR]) was also conducted. The detectability of hepatic arterial focal lesions was compared using the Jackknife free-response receiver operating characteristic analysis. Non-inferiority was satisfied if the margin of the lower limit of 95%CI of the difference in figure-of-merit was less than -0.1. RESULTS Mean overall arterial phase image quality scores with ULDCT using DLM and SDCT using MBIR were 4.35 ± 0.57 and 4.08 ± 0.58, showing noninferiority (difference: -0.269; 95 %CI, -0.374 to -0.164). ULDCT using DLM showed a significantly superior contrast-to-noise ratio of arterial enhancing lesion (p < 0.05). Figure-of-merit for detectability of arterial hepatic focal lesion was 0.986 for ULDCT using DLM and 0.963 for SDCT using MBIR, showing noninferiority (difference: -0.023, 95 %CI: -0.016 to 0.063). CONCLUSION ULDCT using DLM with 66.7% dose reduction showed non-inferior overall image quality and detectability of arterial focal hepatic lesion compared to SDCT using MBIR.
Collapse
Affiliation(s)
- Hyun Joo Lee
- Department of Radiology, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | - Jin Sil Kim
- Department of Radiology, College of Medicine, Ewha Womans University, Seoul, Republic of Korea.
| | - Jeong Kyong Lee
- Department of Radiology, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | - Hye Ah Lee
- Clinical Trial Center, Mokdong Hospital, Ewha Womans University, Seoul, Republic of Korea
| | - Seongyong Pak
- Department of Biomedical Engineering, Asan Medical Institute of Convergence Science and Technology,Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
16
|
Bae JS, Lee JM, Kim SW, Park S, Han S, Yoon JH, Joo I, Hong H. Low-contrast-dose liver CT using low monoenergetic images with deep learning-based denoising for assessing hepatocellular carcinoma: a randomized controlled noninferiority trial. Eur Radiol 2022; 33:4344-4354. [PMID: 36576547 DOI: 10.1007/s00330-022-09298-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 09/29/2022] [Accepted: 11/13/2022] [Indexed: 12/29/2022]
Abstract
OBJECTIVE Low monoenergetic images obtained using noise-reduction techniques may reduce CT contrast media requirements. We aimed to investigate the effectiveness of low-contrast-dose CT using dual-energy CT and deep learning-based denoising (DLD) techniques in patients at high risk of hepatocellular carcinoma (HCC). METHODS We performed a prospective, randomized controlled noninferiority trial at a tertiary hospital between June 2019 and August 2020 (NCT04027556). Patients at high risk of HCC were randomly assigned (1:1) to the standard-contrast-dose group or low-contrast-dose group, which targeted a 40% reduction in contrast medium dose based on lean body weight. HCC conspicuity on arterial phase images was the primary endpoint with a noninferiority margin of 0.2. Images were independently assessed by three radiologists; model-based iterative reconstruction (MBIR) images of the standard-contrast-dose group and low monoenergetic (50-keV) DLD images of the low-contrast-dose group were compared using a generalized estimating equation. RESULTS Ninety participants (age 59 ± 10 years; 68 men) were analyzed. Compared with the standard-contrast-dose group (n = 47), 40% less contrast media was used in the low-contrast-dose group (n = 43) (107.0 ± 17.1 mL vs. 64.5 ± 11.3 mL, p < 0.001). In the arterial phase, HCC conspicuity on 50-keV DLD images in the low-contrast-dose group was noninferior to that of MBIR images in the standard-contrast-dose group (2.92 vs. 2.56; difference, 0.36; 95% confidence interval, -0.13 to ∞; p = 0.013). CONCLUSIONS The contrast dose in liver CT can be reduced by 40% without impairing HCC conspicuity when using 50-keV and DLD techniques. KEY POINTS • In the arterial phase, hepatocellular carcinoma conspicuity on 50-keV deep learning-based denoising images in the low-contrast-dose group was noninferior to that of model-based iterative reconstruction images in the standard-contrast-dose group. • HCC detection was comparable between 50-keV deep learning-based denoising images in the low-contrast-dose group and model-based iterative reconstruction images in the standard-contrast-dose group.
Collapse
Affiliation(s)
- Jae Seok Bae
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea. .,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
| | - Se Woo Kim
- Department of Radiology, Armed Forces Daejeon Hospital, 90, Jaun-ro, Yuseong-gu, Daejeon, 34059, Republic of Korea
| | - Sungeun Park
- Department of Radiology, Konkuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul, 05030, Republic of Korea
| | - Seungchul Han
- Department of Radiology, Samsung Medical Center, 81, Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
| | - Hyunsook Hong
- Division of Biostatistics, Medical Research Collaborating Center, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
| |
Collapse
|
17
|
Choi H, Park EA, Ahn C, Kim JH, Lee W, Jeong B. Performance of 1-mm non-gated low-dose chest computed tomography using deep learning-based noise reduction for coronary artery calcium scoring. Eur Radiol 2022; 33:3839-3847. [PMID: 36520181 DOI: 10.1007/s00330-022-09300-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 08/31/2022] [Accepted: 11/13/2022] [Indexed: 12/23/2022]
Abstract
OBJECTIVE To investigate performance of 1-mm, sharp kernel, low-dose chest computed tomography (LDCT) for coronary artery calcium scoring (CACS) using deep learning (DL)-based denoising technique. METHODS This retrospective, intra-individual comparative study consisted of four image datasets of 131 participants who underwent LDCT and calcium CT on the same day between January and February 2020; 1-mm LDCT with DL, 1-mm LDCT with iterative reconstruction (IR), 3-mm LDCT, and calcium CT. CACS from calcium CT were considered as reference and CACS were categorized as 0, 1-10, 11-100, 101-400, and > 400. We compared CACS from LDCTs with that from calcium CT. RESULTS Mean CACS was 104.8 ± 249.1 and proportion of positive CACS was 45% (59/131). CACS from LDCT images tended to be underestimated than those from calcium CT: 1-mm LDCT with DL (93.5 ± 249.6, p = 0.002), 1-mm LDCT with IR (94.7 ± 249.9, p < 0.001), and 3-mm LDCT (90.3 ± 245.3, p = 0.004). All LDCT datasets showed excellent agreement with calcium CT: intraclass correlation coefficient (ICC) = 0.961 (95% confidence interval (CI), 0.945-0.972) for DL, 0.969 (95% CI, 0.956-0.978) for IR, and 0.952 (95% CI, 0.932-0.966) for 3-mm LDCT; weighted kappa for CACS classification, 0.930 (95% CI, 0.893-0.966) for 1-mm LDCT with DL, 0.908 (95% CI, 0.866-0.950) for 1-mm LDCT with IR, and 0.846 (95% CI, 0.780-0.912) for 3-mm LDCT. The accuracy of CACS classification of 1-mm LDCT with DL (90%) tended to be better than 1-mm LDCT with IR (87%) and 3-mm LDCT (84.7%) (p = 0.10). CONCLUSION DL-based noise reduction algorithm can offer reliable calcium scores in 1-mm LDCT reconstructed with sharp kernel. KEY POINTS • Deep learning (DL)-based noise reduction enables calcium scoring at 1-mm, sharp kernel reconstructed low-dose chest CT (LDCT). • Both iterative reconstruction and DL-based noise reduction underestimated calcium score, but agreement were excellent with those from calcium CT. • Accuracy of categorical classification of calcium scoring tended to be highest in 1-mm LDCT with DL compared to 1-mm LDCT with IR and 3-mm LDCT (90%, 87%, and 84.7%, p = 0.10).
Collapse
Affiliation(s)
- Hyewon Choi
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102 Heukseok-ro, Dongjak-gu, Seoul, 06973, Republic of Korea
| | - Eun-Ah Park
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
| | - Chulkyun Ahn
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
- ClariPi Research, Seoul, 03088, Republic of Korea
| | - Jong-Hyo Kim
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
- ClariPi Research, Seoul, 03088, Republic of Korea
- Center for Medical-IT Convergence Technology Research, Advanced Institutes of Convergence Technology, Suwon, 16229, Republic of Korea
| | - Whal Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
| | - Baren Jeong
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
| |
Collapse
|
18
|
Balogh ZA, Janos Kis B. Comparison of CT noise reduction performances with deep learning-based, conventional, and combined denoising algorithms. Med Eng Phys 2022; 109:103897. [DOI: 10.1016/j.medengphy.2022.103897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 09/18/2022] [Accepted: 09/22/2022] [Indexed: 11/29/2022]
|
19
|
Chun M, Choi JH, Kim S, Ahn C, Kim JH. Fully automated image quality evaluation on patient CT: Multi-vendor and multi-reconstruction study. PLoS One 2022; 17:e0271724. [PMID: 35857804 PMCID: PMC9299323 DOI: 10.1371/journal.pone.0271724] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 07/06/2022] [Indexed: 12/21/2022] Open
Abstract
While the recent advancements of computed tomography (CT) technology have contributed in reducing radiation dose and image noise, an objective evaluation of image quality in patient scans has not yet been established. In this study, we present a patient-specific CT image quality evaluation method that includes fully automated measurements of noise level, structure sharpness, and alteration of structure. This study used the CT images of 120 patients from four different CT scanners reconstructed with three types of algorithm: filtered back projection (FBP), vendor-specific iterative reconstruction (IR), and a vendor-agnostic deep learning model (DLM, ClariCT.AI, ClariPi Inc.). The structure coherence feature (SCF) was used to divide an image into the homogeneous (RH) and structure edge (RS) regions, which in turn were used to localize the regions of interests (ROIs) for subsequent analysis of image quality indices. The noise level was calculated by averaging the standard deviations from five randomly selected ROIs on RH, and the mean SCFs on RS was used to estimate the structure sharpness. The structure alteration was defined by the standard deviation ratio between RS and RH on the subtraction image between FBP and IR or DLM, in which lower structure alterations indicate successful noise reduction without degradation of structure details. The estimated structure sharpness showed a high correlation of 0.793 with manually measured edge slopes. Compared to FBP, IR and DLM showed 34.38% and 51.30% noise reduction, 2.87% and 0.59% lower structure sharpness, and 2.20% and -12.03% structure alteration, respectively, on an average. DLM showed statistically superior performance to IR in all three image quality metrics. This study is expected to contribute to enhance the CT protocol optimization process by allowing a high throughput and quantitative image quality evaluation during the introduction or adjustment of lower-dose CT protocol into routine practice.
Collapse
Affiliation(s)
- Minsoo Chun
- Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital, Gyeonggi-do, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jin Hwa Choi
- Department of Radiation Oncology, Chung-Ang University College of Medicine, Seoul, Republic of Korea
| | - Sihwan Kim
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
| | - Chulkyun Ahn
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
- ClariPi Research, Seoul, Republic of Korea
| | - Jong Hyo Kim
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
- ClariPi Research, Seoul, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
- Center for Medical-IT Convergence Technology Research, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| |
Collapse
|
20
|
Ng CKC. Artificial Intelligence for Radiation Dose Optimization in Pediatric Radiology: A Systematic Review. CHILDREN 2022; 9:children9071044. [PMID: 35884028 PMCID: PMC9320231 DOI: 10.3390/children9071044] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 07/11/2022] [Accepted: 07/11/2022] [Indexed: 01/19/2023]
Abstract
Radiation dose optimization is particularly important in pediatric radiology, as children are more susceptible to potential harmful effects of ionizing radiation. However, only one narrative review about artificial intelligence (AI) for dose optimization in pediatric computed tomography (CT) has been published yet. The purpose of this systematic review is to answer the question “What are the AI techniques and architectures introduced in pediatric radiology for dose optimization, their specific application areas, and performances?” Literature search with use of electronic databases was conducted on 3 June 2022. Sixteen articles that met selection criteria were included. The included studies showed deep convolutional neural network (CNN) was the most common AI technique and architecture used for dose optimization in pediatric radiology. All but three included studies evaluated AI performance in dose optimization of abdomen, chest, head, neck, and pelvis CT; CT angiography; and dual-energy CT through deep learning image reconstruction. Most studies demonstrated that AI could reduce radiation dose by 36–70% without losing diagnostic information. Despite the dominance of commercially available AI models based on deep CNN with promising outcomes, homegrown models could provide comparable performances. Future exploration of AI value for dose optimization in pediatric radiology is necessary due to small sample sizes and narrow scopes (only three modalities, CT, positron emission tomography/magnetic resonance imaging and mobile radiography, and not all examination types covered) of existing studies.
Collapse
Affiliation(s)
- Curtise K. C. Ng
- Curtin Medical School, Curtin University, GPO Box U1987, Perth, WA 6845, Australia; or ; Tel.: +61-8-9266-7314; Fax: +61-8-9266-2377
- Curtin Health Innovation Research Institute (CHIRI), Faculty of Health Sciences, Curtin University, GPO Box U1987, Perth, WA 6845, Australia
| |
Collapse
|
21
|
Seo JY, Joo I, Yoon JH, Kang HJ, Kim S, Kim JH, Ahn C, Lee JM. Deep learning-based reconstruction of virtual monoenergetic images of kVp-switching dual energy CT for evaluation of hypervascular liver lesions: Comparison with standard reconstruction technique. Eur J Radiol 2022; 154:110390. [PMID: 35724579 DOI: 10.1016/j.ejrad.2022.110390] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 01/12/2022] [Accepted: 05/31/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To investigate clinical applicability of deep learning(DL)-based reconstruction of virtual monoenergetic images(VMIs) of arterial phase liver CT obtained by rapid kVp-switching dual-energy CT for evaluation of hypervascular liver lesions. MATERIALS AND METHODS We retrospectively included 109 patients who had available late arterial phase liver CT images of the liver obtained with a rapid switching kVp DECT scanner for suspicious intra-abdominal malignancies. Two VMIs of 70 keV and 40 keV were reconstructed using adaptive statistical iterative reconstruction (ASiR-V) for arterial phase scans. VMIs at 40 keV were additionally reconstructed with a vendor-agnostic DL-based reconstruction technique (ClariCT.AI, ClariPi, DL 40 keV). Qualitative, quantitative image quality and subjective diagnostic acceptability were compared according to reconstruction techniques. RESULTS In qualitative analysis, DL 40 keV images showed less image noise (4.55 vs 3.11 vs 3.95, p < 0.001), better image sharpness (4.75 vs 4.16 vs 4.3, p < 0.001), better image contrast (4.98 vs 4.72 vs 4.19, p < 0.017), better lesion conspicuity (4.61 vs 4.23 vs 3.4, p < 0.001) and diagnostic acceptability (4.59 vs 3.88 vs 4.09, p < 0.001) compared with ASiR-V 40 keV or 70 keV image sets. In quantitative analysis, DL 40 keV significantly reduced image noise relative to ASiR-V 40 keV images (49.9%, p < 0.001) and ASiR-V 70 keV images (85.2%, p = 0.012). DL 40 keV images showed significantly higher CNRlesion to the liver and SNRliver than ASiR-V 40 keV image and 70 keV images (p < 0.001). CONCLUSION DL-based reconstruction of 40 keV images using vendor-agnostic software showed greater noise reduction, better lesion conspicuity, image contrast, image sharpness, and higher overall image diagnostic acceptability than ASiR for 40 keV or 70 keV images in patients with hypervascular liver lesions.
Collapse
Affiliation(s)
- June Young Seo
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Hyo Jin Kang
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Sewoo Kim
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Jong Hyo Kim
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea; Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea; Center for Medical-IT Convergence Technology Research, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea; Research Institute, ClariPi, Seoul, Republic of Korea
| | - Chulkyun Ahn
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea; Research Institute, ClariPi, Seoul, Republic of Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
22
|
Lee T, Lee JM, Yoon JH, Joo I, Bae JS, Yoo J, Kim JH, Ahn C, Kim JH. Deep learning-based image reconstruction of 40-keV virtual monoenergetic images of dual-energy CT for the assessment of hypoenhancing hepatic metastasis. Eur Radiol 2022; 32:6407-6417. [PMID: 35380228 DOI: 10.1007/s00330-022-08728-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/19/2022] [Accepted: 03/10/2022] [Indexed: 12/18/2022]
Abstract
OBJECTIVES To evaluate the diagnostic value of deep learning model (DLM) reconstructed dual-energy CT (DECT) low-keV virtual monoenergetic imaging (VMI) for assessing hypoenhancing hepatic metastases. METHODS This retrospective study included 131 patients who underwent contrast-enhanced DECT (80-kVp and 150-kVp with a tin filter) in the portal venous phase for hepatic metastasis surveillance. Linearly blended images simulating 100-kVp images (100-kVp), standard 40-keV VMI images (40-keV VMI), and post-processed 40-keV VMI using a vendor-agnostic DLM (i.e., DLM 40-keV VMI) were reconstructed. Lesion conspicuity and diagnostic acceptability were assessed by three independent reviewers and compared using the Wilcoxon signed-rank test. The contrast-to-noise ratios (CNRs) were also measured placing ROIs in metastatic lesions and liver parenchyma. The detection performance of hepatic metastases was assessed by using a jackknife alternative free-response ROC method. The consensus by two independent radiologists was used as the reference standard. RESULTS DLM 40-keV VMI, compared to 40-keV VMI and 100-kVp, showed a higher lesion-to-liver CNR (8.25 ± 3.23 vs. 6.05 ± 2.38 vs. 5.99 ± 2.00), better lesion conspicuity (4.3 (4.0-4.7) vs. 3.7 (3.7-4.0) vs. 3.7 (3.3-4.0)), and better diagnostic acceptability (4.3 (4.0-4.3) vs. 3.0 (2.7-3.3) vs. 4.0 (4.0-4.3)) (p < 0.001 for all). For lesion detection (246 hepatic metastases in 68 patients), the figure of merit was significantly higher with DLM 40-keV VMI than with 40-keV VMI (0.852 vs. 0.822, p = 0.012), whereas no significant difference existed between DLM 40-keV VMI and 100-kVp (0.852 vs. 0.842, p = 0.31). CONCLUSIONS DLM 40-keV VMI provided better image quality and comparable diagnostic performance for detecting hypoenhancing hepatic metastases compared to linearly blended images. KEY POINTS • DLM 40-keV VMI provides a superior image quality compared with 40-keV or 100-kVp for assessing hypoenhancing hepatic metastasis. • DLM 40-keV VMI has the highest CNR and lesion conspicuity score for hypoenhancing hepatic metastasis due to noise reduction and structural preservation. • DLM 40-keV VMI provides higher lesion detectability than standard 40-keV VMI (p = 0.012).
Collapse
Affiliation(s)
- Taehee Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea. .,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea. .,Institute of Radiation Medicine, Seoul National University Medical Research Center, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Ijin Joo
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.,Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jae Seok Bae
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jeongin Yoo
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Jae Hyun Kim
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Chulkyun Ahn
- Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Korea
| | - Jong Hyo Kim
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.,Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Korea.,Center for Medical-IT Convergence Technology Research, Advanced Institutes of Convergence Technology, Suwon, 16229, Korea
| |
Collapse
|
23
|
Bie Y, Yang S, Li X, Zhao K, Zhang C, Zhong H. Impact of deep learning-based image reconstruction on image quality compared with adaptive statistical iterative reconstruction-Veo in renal and adrenal computed tomography. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:409-418. [PMID: 35124575 PMCID: PMC9108564 DOI: 10.3233/xst-211105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 12/28/2021] [Accepted: 01/16/2022] [Indexed: 06/14/2023]
Abstract
OBJECTIVE To evaluate image quality of deep learning-based image reconstruction (DLIR) in contrast-enhanced renal and adrenal computed tomography (CT) compared with adaptive statistical iterative reconstruction-Veo (ASiR-V). METHODS We prospectively recruited 52 patients. All images were reconstructed with ASiR-V 30%, ASiR-V 70%, and DLIR at low, medium, and high reconstruction strengths. CT number, noise, noise reduction rate, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured and calculated within the region of interest (ROI) on subcutaneous fat, bilateral renal cortices, renal medulla, renal arteries, and adrenal glands. For qualitative analyses, the differentiation of the renal cortex and medulla, conspicuity of the adrenal gland boundary, sharpness, artifacts, and subjective noise were assessed. The overall image quality was calculated on a scale from 0 (worst) to 15 (best) based on the five values above and the score≥9 was acceptable. RESULTS CT number does not significantly differ between the reconstruction datasets. Noise does not significantly differ between ASiR-V 30% and DLIR-L, but it is significantly lower using ASiR-V 70%, DLIR-M, and DLIR-H. The noise reduction rate relative to ASiR-V 30% is significantly different between the DLIR groups and ASiR-V 70%, and DLIR-H yields the highest noise reduction rate (61.6%). SNR and CNR are higher for DLIR-M, DLIR-H, and ASiR-V 70% than for ASiR-V 30% and DLIR-L. DLIR-H shows the best SNR and CNR. The overall image quality yields the same pattern for DLIR-H, with the highest score. Percentages of cases with overall image quality score≥9 are 100% (DLIR-H), 94.23% (DLIR-M), 90.38% (ASiR-V70%), 67.31% (DLIR-L), and 63.46% (ASiR-V30%), respectively. CONCLUSIONS DLIR significantly improved the objective and subjective image quality of renal and adrenal CTs, yielding superior noise reduction compared with ASiR-V.
Collapse
Affiliation(s)
- Yifan Bie
- Department of Radiology, the Second Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Shuo Yang
- Department of Radiology, the Second Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Xingchao Li
- Department of Radiology, the Second Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Kun Zhao
- Department of Radiology, the Second Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Changlei Zhang
- Department of Radiology, the Second Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| | - Hai Zhong
- Department of Radiology, the Second Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
| |
Collapse
|
24
|
Yoon H, Kim J, Lim HJ, Lee MJ. Image quality assessment of pediatric chest and abdomen CT by deep learning reconstruction. BMC Med Imaging 2021; 21:146. [PMID: 34629049 PMCID: PMC8503996 DOI: 10.1186/s12880-021-00677-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 09/28/2021] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Efforts to reduce the radiation dose have continued steadily, with new reconstruction techniques. Recently, image denoising algorithms using artificial neural networks, termed deep learning reconstruction (DLR), have been applied to CT image reconstruction to overcome the drawbacks of iterative reconstruction (IR). The purpose of our study was to compare the objective and subjective image quality of DLR and IR on pediatric abdomen and chest CT images. METHODS This retrospective study included pediatric body CT images from February 2020 to October 2020, performed on 51 patients (34 boys and 17 girls; age 1-18 years). Non-contrast chest CT (n = 16), contrast-enhanced chest CT (n = 12), and contrast-enhanced abdomen CT (n = 23) images were included. Standard 50% adaptive statistical iterative reconstruction V (ASIR-V) images were compared to images with 100% ASIR-V and DLR at medium and high strengths. Attenuation, noise, contrast to noise ratio (CNR), and signal to noise (SNR) measurements were performed. Overall image quality, artifacts, and noise were subjectively assessed by two radiologists using a four-point scale (superior, average, suboptimal, and unacceptable). A phantom scan was performed including the dose range of the clinical images used in our study, and the noise power spectrum (NPS) was calculated. Quantitative and qualitative parameters were compared using repeated-measures analysis of variance (ANOVA) with Bonferroni correction and Wilcoxon signed-rank tests. RESULTS DLR had better CNR and SNR than 50% ASIR-V in both pediatric chest and abdomen CT images. When compared with 50% ASIR-V, high strength DLR was associated with noise reduction in non-contrast chest CT (33.0%), contrast-enhanced chest CT (39.6%), and contrast-enhanced abdomen CT (38.7%) with increases in CNR at 149.1%, 105.8%, and 53.1% respectively. The subjective assessment of overall image quality and the noise was also better on DLR images (p < 0.001). However, there was no significant difference in artifacts between reconstruction methods. From NPS analysis, DLR methods showed a pattern of reducing the magnitude of noise while maintaining the texture. CONCLUSION Compared with 50% ASIR-V, DLR improved pediatric body CT images with significant noise reduction. However, artifacts were not improved by DLR, regardless of strength.
Collapse
Affiliation(s)
- Haesung Yoon
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - Jisoo Kim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - Hyun Ji Lim
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - Mi-Jung Lee
- Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea.
| |
Collapse
|
25
|
Park SB. Advances in deep learning for computed tomography denoising. World J Clin Cases 2021; 9:7614-7619. [PMID: 34621813 PMCID: PMC8462260 DOI: 10.12998/wjcc.v9.i26.7614] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 05/12/2021] [Accepted: 08/17/2021] [Indexed: 02/06/2023] Open
Abstract
Computed tomography (CT) has seen a rapid increase in use in recent years. Radiation from CT accounts for a significant proportion of total medical radiation. However, given the known harmful impact of radiation exposure to the human body, the excessive use of CT in medical environments raises concerns. Concerns over increasing CT use and its associated radiation burden have prompted efforts to reduce radiation dose during the procedure. Therefore, low-dose CT has attracted major attention in the radiology, since CT-associated x-ray radiation carries health risks for patients. The reduction of the CT radiation dose, however, compromises the signal-to-noise ratio, which affects image quality and diagnostic performance. Therefore, several denoising methods have been developed and applied to image processing technologies with the goal of reducing image noise. Recently, deep learning applications that improve image quality by reducing the noise and artifacts have become commercially available for diagnostic imaging. Deep learning image reconstruction shows great potential as an advanced reconstruction method to improve the quality of clinical CT images. These improvements can provide significant benefit to patients regardless of their disease, and further advances are expected in the near future.
Collapse
Affiliation(s)
- Sung Bin Park
- Department of Radiology, Chung-Ang University Hospital, Seoul 06973, South Korea
| |
Collapse
|
26
|
Yeoh H, Hong SH, Ahn C, Choi JY, Chae HD, Yoo HJ, Kim JH. Deep Learning Algorithm for Simultaneous Noise Reduction and Edge Sharpening in Low-Dose CT Images: A Pilot Study Using Lumbar Spine CT. Korean J Radiol 2021; 22:1850-1857. [PMID: 34431248 PMCID: PMC8546130 DOI: 10.3348/kjr.2021.0140] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 05/27/2021] [Accepted: 06/01/2021] [Indexed: 11/16/2022] Open
Abstract
Objective The purpose of this study was to assess whether a deep learning (DL) algorithm could enable simultaneous noise reduction and edge sharpening in low-dose lumbar spine CT. Materials and Methods This retrospective study included 52 patients (26 male and 26 female; median age, 60.5 years) who had undergone CT-guided lumbar bone biopsy between October 2015 and April 2020. Initial 100-mAs survey images and 50-mAs intraprocedural images were reconstructed by filtered back projection. Denoising was performed using a vendor-agnostic DL model (ClariCT.AI™, ClariPI) for the 50-mAS images, and the 50-mAs, denoised 50-mAs, and 100-mAs CT images were compared. Noise, signal-to-noise ratio (SNR), and edge rise distance (ERD) for image sharpness were measured. The data were summarized as the mean ± standard deviation for these parameters. Two musculoskeletal radiologists assessed the visibility of the normal anatomical structures. Results Noise was lower in the denoised 50-mAs images (36.38 ± 7.03 Hounsfield unit [HU]) than the 50-mAs (93.33 ± 25.36 HU) and 100-mAs (63.33 ± 16.09 HU) images (p < 0.001). The SNRs for the images in descending order were as follows: denoised 50-mAs (1.46 ± 0.54), 100-mAs (0.99 ± 0.34), and 50-mAs (0.58 ± 0.18) images (p < 0.001). The denoised 50-mAs images had better edge sharpness than the 100-mAs images at the vertebral body (ERD; 0.94 ± 0.2 mm vs. 1.05 ± 0.24 mm, p = 0.036) and the psoas (ERD; 0.42 ± 0.09 mm vs. 0.50 ± 0.12 mm, p = 0.002). The denoised 50-mAs images significantly improved the visualization of the normal anatomical structures (p < 0.001). Conclusion DL-based reconstruction may enable simultaneous noise reduction and improvement in image quality with the preservation of edge sharpness on low-dose lumbar spine CT. Investigations on further radiation dose reduction and the clinical applicability of this technique are warranted.
Collapse
Affiliation(s)
- Hyunjung Yeoh
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Sung Hwan Hong
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
| | - Chulkyun Ahn
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Korea
| | - Ja-Young Choi
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Hee-Dong Chae
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Hye Jin Yoo
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Jong Hyo Kim
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Korea.,Center for Medical-IT Convergence Technology Research, Advanced Institutes of Convergence Technology, Suwon, Korea
| |
Collapse
|
27
|
Choi H, Chang W, Kim JH, Ahn C, Lee H, Kim HY, Cho J, Lee YJ, Kim YH. Dose reduction potential of vendor-agnostic deep learning model in comparison with deep learning-based image reconstruction algorithm on CT: a phantom study. Eur Radiol 2021; 32:1247-1255. [PMID: 34390372 PMCID: PMC8364308 DOI: 10.1007/s00330-021-08199-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 06/11/2021] [Accepted: 07/02/2021] [Indexed: 12/25/2022]
Abstract
Objectives To compare the dose reduction potential (DRP) of a vendor-agnostic deep learning model (DLM, ClariCT.AI) with that of a vendor-specific deep learning–based image reconstruction algorithm (DLR, TrueFidelity™). Methods Computed tomography (CT) images of a multi-sized image quality phantom (Mercury v4.0) were acquired under six radiation dose levels (0.48/0.97/1.93/3.87/7.74/15.47 mGy) and were reconstructed using filtered back projection (FBP) and three strength levels of the DLR (low/medium/high). The FBP images were denoised using the DLM. For all DLM and DLR images, the detectability index (d′) (a task-based detection performance metric) was obtained, under various combinations of three target sizes (10/5/1 mm), five inlets (CT value difference with the background; −895/50/90/335/1000 HU), five phantom diameters (36/31/26/21/16 cm), and six radiation dose levels. Dose reduction potential (DRP) measures the dose reduction made by using DLM or DLR, while yielding d′ equivalent to that of FBP at full dose. Results The DRPs of the DLM, DLR-low, DLR-medium, and DLR-high were 86% (81–88%), 60% (46–67%), 76% (60–81%), and 87% (78–92%), respectively. For 10-mm targets, the DRP of the DLM (87%) was higher than that of all DLR algorithms (58–86%). However, for smaller targets (5 mm/1 mm), the DRPs of the DLR-high (89/88%) were greater than those of the DLM (87/84%). Conclusion The dose reduction potential of the vendor-agnostic DLM was shown to be comparable to that of the vendor-specific DLR at high strength and superior to those of the DLRs at medium and low strengths. Key Points • DRP of the vendor-agnostic model was comparable to that of high-strength vendor-specific model and superior to those of medium- and low-strength models. • Under various radiation dose levels, the deep learning model shows higher detectability indexes compared to FBP. Supplementary Information The online version contains supplementary material available at 10.1007/s00330-021-08199-9.
Collapse
Affiliation(s)
- Hyunsu Choi
- Department of Radiology, Seoul National University Bundang Hospital, 82, Gumi-ro-173-beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Won Chang
- Department of Radiology, Seoul National University Bundang Hospital, 82, Gumi-ro-173-beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea.
| | - Jong Hyo Kim
- Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul National University Medical Research Center, 101 Daehak-ro, Jongno-gu, Seoul, Republic of Korea
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
| | - Chulkyun Ahn
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
| | - Heejin Lee
- Department of Applied bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea
| | - Hae Young Kim
- Department of Radiology, Seoul National University Bundang Hospital, 82, Gumi-ro-173-beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Jungheum Cho
- Department of Radiology, Seoul National University Bundang Hospital, 82, Gumi-ro-173-beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Yoon Jin Lee
- Department of Radiology, Seoul National University Bundang Hospital, 82, Gumi-ro-173-beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Young Hoon Kim
- Department of Radiology, Seoul National University Bundang Hospital, 82, Gumi-ro-173-beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| |
Collapse
|
28
|
Cardobi N, Dal Palù A, Pedrini F, Beleù A, Nocini R, De Robertis R, Ruzzenente A, Salvia R, Montemezzi S, D’Onofrio M. An Overview of Artificial Intelligence Applications in Liver and Pancreatic Imaging. Cancers (Basel) 2021; 13:2162. [PMID: 33946223 PMCID: PMC8124771 DOI: 10.3390/cancers13092162] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 04/27/2021] [Accepted: 04/28/2021] [Indexed: 12/11/2022] Open
Abstract
Artificial intelligence (AI) is one of the most promising fields of research in medical imaging so far. By means of specific algorithms, it can be used to help radiologists in their routine workflow. There are several papers that describe AI approaches to solve different problems in liver and pancreatic imaging. These problems may be summarized in four different categories: segmentation, quantification, characterization and image quality improvement. Segmentation is usually the first step of successive elaborations. If done manually, it is a time-consuming process. Therefore, the semi-automatic and automatic creation of a liver or a pancreatic mask may save time for other evaluations, such as quantification of various parameters, from organs volume to their textural features. The alterations of normal liver and pancreas structure may give a clue to the presence of a diffuse or focal pathology. AI can be trained to recognize these alterations and propose a diagnosis, which may then be confirmed or not by radiologists. Finally, AI may be applied in medical image reconstruction in order to increase image quality, decrease dose administration (referring to computed tomography) and reduce scan times. In this article, we report the state of the art of AI applications in these four main categories.
Collapse
Affiliation(s)
- Nicolò Cardobi
- Radiology Unit, Department of Pathology and Diagnostics, University Hospital of Verona, Piazzale Aristide Stefani, 1, 37126 Verona, Italy; (R.D.R.); (S.M.)
| | - Alessandro Dal Palù
- Department of Mathematical, Physical and Computer Sciences, University of Parma, 43121 Parma, Italy;
| | - Federica Pedrini
- Department of Radiology, G.B. Rossi University Hospital, University of Verona, 37129 Verona, Italy; (F.P.); (A.B.); (M.D.)
| | - Alessandro Beleù
- Department of Radiology, G.B. Rossi University Hospital, University of Verona, 37129 Verona, Italy; (F.P.); (A.B.); (M.D.)
| | - Riccardo Nocini
- Otolaryngology-Head and Neck Surgery Department, University Hospital of Verona, Piazzale Aristide Stefani, 1, 37126 Verona, Italy;
| | - Riccardo De Robertis
- Radiology Unit, Department of Pathology and Diagnostics, University Hospital of Verona, Piazzale Aristide Stefani, 1, 37126 Verona, Italy; (R.D.R.); (S.M.)
| | - Andrea Ruzzenente
- Department of Surgery, General and Hepatobiliary Surgery, University Hospital G.B. Rossi, University and Hospital Trust of Verona, 37126 Verona, Italy;
| | - Roberto Salvia
- Unit of General and Pancreatic Surgery, Department of Surgery and Oncology, University of Verona Hospital Trust, 37126 Verona, Italy;
| | - Stefania Montemezzi
- Radiology Unit, Department of Pathology and Diagnostics, University Hospital of Verona, Piazzale Aristide Stefani, 1, 37126 Verona, Italy; (R.D.R.); (S.M.)
| | - Mirko D’Onofrio
- Department of Radiology, G.B. Rossi University Hospital, University of Verona, 37129 Verona, Italy; (F.P.); (A.B.); (M.D.)
| |
Collapse
|