1
|
Comments on the 2023 ESC guidelines for the management of cardiomyopathies. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2024; 77:285-289. [PMID: 38048845 DOI: 10.1016/j.rec.2023.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 11/16/2023] [Indexed: 12/06/2023]
|
2
|
Fogante M, Volpato G, Esposto Pirani P, Cela F, Compagnucci P, Valeri Y, Selimi A, Alfieri M, Brugiatelli L, Belleggia S, Coraducci F, Argalia G, Casella M, Dello Russo A, Schicchi N. Cardiac Magnetic Resonance and Cardiac Implantable Electronic Devices: Are They Truly Still "Enemies"? MEDICINA (KAUNAS, LITHUANIA) 2024; 60:522. [PMID: 38674168 PMCID: PMC11051994 DOI: 10.3390/medicina60040522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 03/15/2024] [Accepted: 03/20/2024] [Indexed: 04/28/2024]
Abstract
The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.
Collapse
Affiliation(s)
- Marco Fogante
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.)
| | - Giovanni Volpato
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Paolo Esposto Pirani
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.)
| | - Fatjon Cela
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.)
| | - Paolo Compagnucci
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Yari Valeri
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Adelina Selimi
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Michele Alfieri
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Leonardo Brugiatelli
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Sara Belleggia
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Francesca Coraducci
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
| | - Giulio Argalia
- Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy; (P.E.P.); (F.C.); (G.A.)
| | - Michela Casella
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
- Department of Clinical, Special and Dental Sciences, Marche Polytechnic University, 60121 Ancona, Italy
| | - Antonio Dello Russo
- Cardiology and Arrhythmology Clinic, University Hospital “Azienda Ospedaliero-Universitaria delle Marche”, 60126 Ancona, Italy; (G.V.); (P.C.); (Y.V.); (A.S.); (M.A.); (L.B.); (S.B.); (F.C.); (M.C.); (A.D.R.)
- Department of Biomedical Sciences and Public Health, Marche Polytechnic University, 60121 Ancona, Italy
| | - Nicolò Schicchi
- Cardiovascular Radiological Diagnostics, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy;
| |
Collapse
|
3
|
Kim D, Collins JD, White JA, Hanneman K, Lee DC, Patel AR, Hu P, Litt H, Weinsaft JW, Davids R, Mukai K, Ng MY, Luetkens JA, Roguin A, Rochitte CE, Woodard PK, Manisty C, Zareba KM, Mont L, Bogun F, Ennis DB, Nazarian S, Webster G, Stojanovska J. SCMR expert consensus statement for cardiovascular magnetic resonance of patients with a cardiac implantable electronic device. J Cardiovasc Magn Reson 2024; 26:100995. [PMID: 38219955 PMCID: PMC11211236 DOI: 10.1016/j.jocmr.2024.100995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 01/09/2024] [Indexed: 01/16/2024] Open
Abstract
Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.
Collapse
Affiliation(s)
- Daniel Kim
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA.
| | | | - James A White
- Departments of Cardiac Sciences and Diagnostic Imaging, Cummings School of Medicine, University of Calgary, Calgary, Canada
| | - Kate Hanneman
- Department of Medical Imaging, University Medical Imaging Toronto, Toronto General Hospital and Peter Munk Cardiac Centre, University of Toronto, Toronto, Canada
| | - Daniel C Lee
- Department of Medicine (Division of Cardiology), Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Amit R Patel
- Cardiovascular Division, University of Virginia, Charlottesville, VA, USA
| | - Peng Hu
- School of Biomedical Engineering, ShanghaiTech University, Shanghai, China
| | - Harold Litt
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, PA, USA
| | - Jonathan W Weinsaft
- Department of Medicine (Division of Cardiology), Weill Cornell Medicine, New York, NY, USA
| | - Rachel Davids
- SHS AM NAM USA DI MR COLLAB ADV-APPS, Siemens Medical Solutions USA, Inc., Chicago, Il, USA
| | - Kanae Mukai
- Salinas Valley Memorial Healthcare System, Ryan Ranch Center for Advanced Diagnostic Imaging, Monterey, CA, USA
| | - Ming-Yen Ng
- Department of Diagnostic Radiology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, the Hong Kong Special Administrative Region of China
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany
| | - Ariel Roguin
- Department of Cardiology, Hillel Yaffe Medical Center, Hadera and Faculty of Medicine. Technion - Israel Institute of Technology, Israel
| | - Carlos E Rochitte
- Heart Institute, InCor, University of São Paulo Medical School, São Paulo, SP, Brazil
| | - Pamela K Woodard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, St. Louis, MO, USA
| | - Charlotte Manisty
- Institute of Cardiovascular Science, University College London, London, UK
| | - Karolina M Zareba
- Division of Cardiovascular Medicine, The Ohio State University, Columbus, OH, USA
| | - Lluis Mont
- Cardiovascular Institute, Hospital Clínic, University of Barcelona, Catalonia, Spain
| | - Frank Bogun
- Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, MI, USA
| | - Daniel B Ennis
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Saman Nazarian
- Section of Cardiac Electrophysiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, PA, USA
| | - Gregory Webster
- Department of Pediatrics (Cardiology), Ann & Robert H. Lurie Children's Hospital, Chicago, IL, USA
| | - Jadranka Stojanovska
- Department of Radiology, Grossman School of Medicine, New York University, New York, NY, USA
| |
Collapse
|
4
|
Nissan N, Ochoa-Albiztegui RE, Fruchtman H, Gluskin J, Eskreis-Winkler S, Horvat JV, Kosmidou I, Meng A, Pinker K, Jochelson MS. Breast MRI in patients with implantable loop recorder: initial experience. Eur Radiol 2024; 34:155-164. [PMID: 37555957 PMCID: PMC11181953 DOI: 10.1007/s00330-023-10025-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 05/10/2023] [Accepted: 06/13/2023] [Indexed: 08/10/2023]
Abstract
OBJECTIVES To investigate the feasibility of breast MRI exams and guided biopsies in patients with an implantable loop recorder (ILR) as well as the impact ILRs may have on image interpretation. MATERIALS AND METHODS This retrospective study examined breast MRIs of patients with ILR, from April 2008 to September 2022. Radiological reports and electronic medical records were reviewed for demographic characteristics, safety concerns, and imaging findings. MR images were analyzed and compared statistically for artifact quantification on the various pulse sequences. RESULTS Overall, 40/82,778 (0.049%) MRIs during the study period included ILR. All MRIs were completed without early termination. No patient-related or device-related adverse events occurred. ILRs were most commonly located in the left lower-inner quadrant (64.6%). The main artifact was a signal intensity (SI) void in a dipole formation in the ILR bed with or without areas of peripheral high SI. Artifacts appeared greatest in the cranio-caudal axis (p < 0.001), followed by the anterior-posterior axis (p < 0.001), and then the right-left axis. High peripheral rim-like SI artifacts appeared on the post-contrast and subtracted T1-weighted images, mimicking suspicious enhancement. Artifacts were most prominent on diffusion-weighted (p < 0.001), followed by T2-weighted and T1-weighted images. In eight patients, suspicious findings were found on MRI, resulting in four additional malignant lesions. Of six patients with left breast cancer, the tumor was completely visible in five cases and partially obscured in one. CONCLUSION Breast MRI is feasible and safe among patients with ILR and may provide a significant diagnostic value, albeit with localized, characteristic artifacts. CLINICAL RELEVANCE STATEMENT Indicated breast MRI exams and guided biopsies can be safely performed in patients with implantable loop recorder. Nevertheless, radiologists should be aware of associated limitations including limited assessment of the inner left breast and pseudo-enhancement artifacts. KEY POINTS • Breast MRI in patients with an implantable loop recorder is an infrequent, feasible, and safe procedure. • Despite limited breast visualization of the implantable loop recorder bed and characteristic artifacts, MRI depicted additional lesions in 8/40 (20%) of cases, half of which were malignant. • Breast MRI in patients with an implantable loop recorder should be performed when indicated, taking into consideration typical associated artifacts.
Collapse
Affiliation(s)
- Noam Nissan
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | | | - Hila Fruchtman
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Jill Gluskin
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Sarah Eskreis-Winkler
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Joao V Horvat
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Ioanna Kosmidou
- Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Alicia Meng
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Katja Pinker
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Maxine S Jochelson
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| |
Collapse
|
5
|
Barison A, Ricci F, Pavon AG, Muscogiuri G, Bisaccia G, Camastra G, De Lazzari M, Lanzillo C, Raguso M, Monti L, Vargiu S, Pedrotti P, Piacenti M, Todiere G, Pontone G, Indolfi C, Dellegrottaglie S, Lombardi M, Schwitter J, Aquaro GD. Cardiovascular Magnetic Resonance in Patients with Cardiac Electronic Devices: Evidence from a Multicenter Study. J Clin Med 2023; 12:6673. [PMID: 37892813 PMCID: PMC10607654 DOI: 10.3390/jcm12206673] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 10/11/2023] [Accepted: 10/17/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND Most recent cardiac implantable electronic devices (CIEDs) can safely undergo a cardiovascular magnetic resonance (CMR) scan under certain conditions, but metal artifacts may degrade image quality. The aim of this study was to assess the overall diagnostic yield of CMR and the extent of metal artifacts in a multicenter, multivendor study on CIED patients referred for CMR. METHODS We analyzed 309 CMR scans from 292 patients (age 57 ± 16 years, 219 male) with an MR-conditional pacemaker (n = 122), defibrillator (n = 149), or loop recorder (n = 38); CMR scans were performed in 10 centers from 2012 to 2020; MR-unsafe implants were excluded. Clinical and device parameters were recorded before and after the CMR scan. A visual analysis of metal artifacts was performed for each sequence on a segmental basis, based on a 5-point artifact score. RESULTS The vast majority of CMR scans (n = 255, 83%) were completely performed, while only 32 (10%) were interrupted soon after the first sequences and 22 (7%) were only partly acquired; CMR quality was non-diagnostic in 34 (11%) scans, poor (<1/3 sequences were diagnostic) in 25 (8%), or acceptable (1/3 to 2/3 sequences were diagnostic) in 40 (13%), while most scans (n = 201, 68%) were of overall good quality. No adverse event or device malfunctioning occurred, and only nonsignificant changes in device parameters were recorded. The most affected sequences were SSFP (median score 0.32 [interquartile range 0.07-0.91]), followed by GRE (0.18 [0.02-0.59]) and LGE (0.14 [0.02-0.55]). ICDs induced more artifacts (median score in SSFP images 0.87 [0.50-1.46]) than PMs (0.11 [0.03-0.28]) or ILRs (0.11 [0.00-0.56]). Moreover, most artifacts were located in the anterior, anteroseptal, anterolateral, and apical segments of the LV and in the outflow tract of the RV. CONCLUSIONS CMR is a versatile imaging technique, with a high safety profile and overall good image quality even in patients with MR-conditional CIEDs. Several strategies are now available to optimize image quality, substantially enhancing overall diagnostic yield.
Collapse
Affiliation(s)
- Andrea Barison
- Fondazione Toscana Gabriele Monasterio, 56127 Pisa, Italy
- Life Science Institute, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
| | - Fabrizio Ricci
- Department of Neuroscience, Imaging and Clinical Sciences, G. d’Annunzio University of Chieti-Pescara, 66100 Chieti, Italy
| | - Anna Giulia Pavon
- Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, 6900 Lugano, Switzerland
| | - Giuseppe Muscogiuri
- Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy
| | - Giandomenico Bisaccia
- Department of Neuroscience, Imaging and Clinical Sciences, G. d’Annunzio University of Chieti-Pescara, 66100 Chieti, Italy
| | | | - Manuel De Lazzari
- Department of Cardiac Thoracic and Vascular Sciences and Public Health, University of Padua, 35122 Padova, Italy
| | | | - Mario Raguso
- Ospedale Policlinico Casilino, 00169 Roma, Italy
| | - Lorenzo Monti
- IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy
| | - Sara Vargiu
- Cardiologia 3, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy
| | - Patrizia Pedrotti
- Cardiac Magnetic Resonance Laboratory, Cardiologia 4, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy
| | | | | | - Gianluca Pontone
- Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy
| | - Ciro Indolfi
- Division of Cardiology, Magna Graecia University, 88100 Catanzaro, Italy
- Center for Cardiovascular Research, Magna Graecia University, 88100 Catanzaro, Italy
- Mediterranea Cardiocentro, 80122 Naples, Italy
| | - Santo Dellegrottaglie
- Advanced Cardiovascular Imaging Unit, Ospedale Medico-Chirurgico Accreditato Villa dei Fiori, 80011 Acerra, Italy
| | - Massimo Lombardi
- Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, 20097 Milan, Italy
| | - Juerg Schwitter
- Division of Cardiology, Cardiovascular Department, University Hospital Lausanne—CHUV, 1011 Lausanne, Switzerland
- CMR Center, University Hospital Lausanne—CHUV, 1011 Lausanne, Switzerland
- Faculty of Biology & Medicine, University of Lausanne—UniL, 1015 Lausanne, Switzerland
| | - Giovanni Donato Aquaro
- Academic Radiology Unit, Department of Surgical Medical and Molecular Pathology and Critical Area, University of Pisa, 56126 Pisa, Italy
| | | | | |
Collapse
|
6
|
Hopman LHGA, Zweerink A, van der Lingen ALCJ, Huntelaar MJ, Mulder MJ, Robbers LFHJ, van Rossum AC, van Halm VP, Götte MJW, Allaart CP. Feasibility of CMR Imaging during Biventricular Pacing: Comparison with Invasive Measurement as a Pathway towards a Novel Optimization Strategy. J Clin Med 2023; 12:3998. [PMID: 37373691 PMCID: PMC10298880 DOI: 10.3390/jcm12123998] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/07/2023] [Accepted: 06/10/2023] [Indexed: 06/29/2023] Open
Abstract
OBJECTIVES This prospective pilot study assessed the feasibility of cardiovascular magnetic resonance (CMR) imaging during biventricular (BIV) pacing in patients with a CMR conditional cardiac resynchronization therapy defibrillator (CRT-D) and compared the results with invasive volume measurements. METHODS Ten CRT-D patients underwent CMR imaging prior to device implantation (baseline) and six weeks after device implantation, including CRT-on and CRT-off modes. Left ventricular (LV) function, volumes, and strain measurements of LV dyssynchrony and dyscoordination were assessed. Invasive pressure-volume measurements were performed, matching the CRT settings used during CMR. RESULTS Post-implantation imaging enabled reliable cine assessment, but showed artefacts on late gadolinium enhancement images. After six weeks of CRT, significant reverse remodeling was observed, with a 22.7 ± 11% reduction in LV end-systolic volume during intrinsic rhythm (CRT-off). During CRT-on, the LV ejection fraction significantly improved from 27.4 ± 5.9% to 32.2 ± 8.7% (p < 0.01), and the strain assessment showed the abolition of the left bundle branch block contraction pattern. Invasively measured and CMR-assessed LV hemodynamics during BIV pacing were significantly associated. CONCLUSIONS Post-CRT implantation CMR assessing acute LV pump function is feasible and provides important insights into the effects of BIV pacing on cardiac function and contraction patterns. LV assessment during CMR may constitute a future CRT optimization strategy.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - Cornelis P. Allaart
- Department of Cardiology, Amsterdam UMC, De Boelelaan 1118, 1081 HV Amsterdam, The Netherlands; (L.H.G.A.H.)
| |
Collapse
|