1
|
Elmarsafawy H, Hafez M, Alsawah GA, Bakr A, Rakha S. Long-term outcomes of percutaneous closure of ventricular septal defects in children using different devices: A single centre experience from Egypt. BMC Pediatr 2023; 23:381. [PMID: 37525132 PMCID: PMC10392015 DOI: 10.1186/s12887-023-04194-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 07/18/2023] [Indexed: 08/02/2023] Open
Abstract
BACKGROUND The feasibility of percutaneous closure ventricular septal defects (VSD) in children has been previously proven. However, data on long-term outcomes are limited. We aim to evaluate the long-term outcome of our experience with percutaneous closure of VSD using various occluders. METHODS Retrospective institutional analysis of children who underwent transcatheter closure of perimembranous and muscular VSDs between September 2012 and February 2020. Patient demographics, procedural, and long-term follow-up data were comprehensively analyzed. Patients who lost to follow-up within two years post-procedure were excluded. RESULTS We identified 75 patients (54.7% males) with a median of 66 months (IQR, 46-96). The closure success rate at one year was 95.7%. Complete heart block was detected in two patients early post-procedure and resolved with steroids. The VSDs were perimembranous (52%), muscular (33.33%), and residual (14.67%). Implanted devices were Pfm Nit-Occlud LeˆVSD Coil (42.7%), HyperionTM VSD Muscular Occluder (28%), Amplatzer VSD muscular occluder (10.7%), Amplatzer Duct Occluder (14.7%), Occlutech Muscular VSD Occluder (2.7%), and Amplatzer Duct Occluder II (1.3%). No new arrhythmia or valve regurgitation was detected after two years post-procedure. Persisted complications on long-term follow-up included: residual shunting in 3(4%), mild tricuspid regurgitation in 2(2.7%), and aortic regurgitation in 2(2.7%), with one immediate post-catheterization mild aortic regurgitation worsened during follow-up, requiring surgical repair of VSD three years after device implantation. No deaths were reported. CONCLUSION Long-term outcomes of pediatric transcatheter VSD closure using different devices are satisfactory. Post-procedural adverse events are limited, but long-term surveillance is necessary to monitor their progression.
Collapse
Affiliation(s)
- Hala Elmarsafawy
- Pediatric Cardiology Unit, Pediatrics Department, Mansoura University Faculty of Medicine, El Gomhouria St, Mansoura, Dakahlia Governorate, 35516, Egypt
- Faculty of Medicine, New Mansoura University, New Mansoura City, Egypt
| | - Mona Hafez
- Pediatric Cardiology Unit, Pediatrics Department, Mansoura University Faculty of Medicine, El Gomhouria St, Mansoura, Dakahlia Governorate, 35516, Egypt
| | - Gehan A Alsawah
- Pediatric Cardiology Unit, Pediatrics Department, Mansoura University Faculty of Medicine, El Gomhouria St, Mansoura, Dakahlia Governorate, 35516, Egypt
| | - Asmaa Bakr
- Pediatric Cardiology Unit, Pediatrics Department, Mansoura University Faculty of Medicine, El Gomhouria St, Mansoura, Dakahlia Governorate, 35516, Egypt
| | - Shaimaa Rakha
- Pediatric Cardiology Unit, Pediatrics Department, Mansoura University Faculty of Medicine, El Gomhouria St, Mansoura, Dakahlia Governorate, 35516, Egypt.
| |
Collapse
|
2
|
Song J. Percutaneous Transcatheter Closure of Congenital Ventricular Septal Defects. Korean Circ J 2023; 53:134-150. [PMID: 36914603 PMCID: PMC10011220 DOI: 10.4070/kcj.2022.0336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 12/27/2022] [Indexed: 02/17/2023] Open
Abstract
Ventricular septal defects (VSDs) are the most common kind of congenital heart disease and, if indicated, surgical closure has been accepted as a gold-standard treatment. However, as less-invasive methods are preferred, percutaneous device closure has been developed. After the first VSD closure was performed percutaneously by Lock in 1988, both techniques and devices have developed consistently. A perventricular approach for closure of muscular VSD in small patients and the closure of perimembranous VSD using off-label devices are key remarkable developments. Even though the Amplatzer membranous VSD occluder (Abbott) could not be approved for use due to the high complete atrioventricular conduction block rate, other new devices have shown good results for closure of perimembranous VSDs. However, the transcatheter technique is slightly complicated to perform, and concerns about conduction problems after VSD closure with devices remain. There have been a few reports demonstrating successful closure of subarterial-type VSDs with Amplatzer devices, but long-term issues involving aortic valve damage have not been explored yet. In conclusion, transcatheter VSD closure should be accepted as being as effective and safe as surgery but should only be performed by experienced persons and in specialized institutes because the procedure is complex and requires different techniques. To avoid serious complications, identifying appropriate patient candidates for device closure before the procedure is very important.
Collapse
Affiliation(s)
- Jinyoung Song
- Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
| |
Collapse
|
3
|
Transcatheter closure of ventricular septal defects: preliminary results in children weighing 10 kg or less. Cardiol Young 2022; 33:539-545. [PMID: 35491695 DOI: 10.1017/s1047951122001147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
INTRODUCTION Ventricular septal defect is one of the commonest heart defect in children and closure of this defect with devices has seen a rapid progression over a period of time. The availability of new and safer devices has made the transcatheter closure of ventricular septal defect a suitable option even in young children. AIM The study was done to evaluate the feasibility and complications of device closure of ventricular septal defect in children weighing 10 kg or less with different types of devices. METHODS The present study was undertaken in a newly established dedicated Paediatric Cardiac Unit at a Tertiary Care Hospital. Relevant data were obtained retrospectively from the case files and the catheterisation records and data were analysed for first 50 patients with ventricular septal defect weighing 10 kg or less between March 2018 and March 2021. RESULTS Among these 50 patients selected, device closure was successfully done in 45 (90%) cases while 5 (10%) attempts were unsuccessful for various reasons. The mean weight in this study was 7.46 ± 1.89 kg (2.3-10 kg), 21 (42%) cases were females while 29 (58%) were males; mean age was 19.4 ± 11.88 months (4-48 months). Right heart catheterisation study showed 21 (42%) patients with normal pulmonary artery pressures (no pulmonary artery hypertension). Among 29 patients with pulmonary arterial hypertension, 13 patients (22%) were having mild pulmonary arterial hypertension, 4 (8%) were with moderate pulmonary arterial hypertension, and 12 (24%) were with severe pulmonary arterial hypertension. Mean Qp/Qs was 2.73 ± 0.72 (2.5-4.5) and mean pulmonary vascular resistance was 1.5 ± 1.04 (0.6-4.6 WU). Amplatzer Duct Occluder (ADOI) was used in 15 (30%) cases, 27 (52%) cases were closed with Amplatzer Duct Occluder (ADOII), and the 3 (6%) cases closure was done with Amplatzer muscular ventricular septal defect occluder. CONCLUSIONS Transcatheter closure of ventricular septal defect in children 10 kg or less is feasible and safe alternative to surgical ventricular septal defect closure. The immediate and short-term outcomes have proven this method to be safe and valid.
Collapse
|
4
|
Zheng H, Lin A, Wang L, Xu Y, Zhang Z. The Long-Term Change of Arrhythmias after Transcatheter Closure of Perimembranous Ventricular Septal Defects. Cardiol Res Pract 2021; 2021:1625915. [PMID: 34239725 PMCID: PMC8241517 DOI: 10.1155/2021/1625915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 06/09/2021] [Accepted: 06/12/2021] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVES To observe and analyze the long-term change of different types of arrhythmias after transcatheter closure of perimembranous ventricular septal defect (pmVSD). METHODS We retrospectively collected the data of patients who underwent pmVSD closure in our institution from March 2002 to December 2010. RESULTS One hundred thirty-nine patients met the inclusion criteria, of which 265 (25.5%) had early arrhythmia. They were classified into two categories: conduction abnormality (191/1039; 18.4%) and origin abnormality (94/1039; 9.0%), including 20 patients with both types of arrhythmias. The median follow-up time was 84.5 months, and 103 patients (103/191; 53.9%) with early conduction block got permanent arrhythmias, while only three patients (3/94; 3.2%) with early anomalous origin arrhythmias still had an abnormal electrocardiogram. Serious arrhythmias (28/1039; 2.7%), including II° atrioventricular block (AVB), III° AVB, and complete left bundle branch block (CLBBB), can appear immediately in the early postoperative period (21 patients) or in the late outset (seven patients) after several months or even years (6 months to 8.3 years). Twenty patients (20/21; 95.2%) with serious arrhythmia in the early postoperative period improved after early treatment, but six patients relapsed or worsened during follow-up. At the endpoint, severe arrhythmia persisted in 13 patients, of which four patients got permanent pacemaker implanted, and one patient with recurrent CLBBB died from heart failure. CONCLUSIONS The probability of delayed CAVB or bundle branch block after VSD closure is low but often occurs several years after surgery. Therefore, long-term ECG follow-up should last for several years or even decades. Serious arrhythmias that appear early after transcatheter pmVSD closure may impose a risk of recurrence although they have been cured already. Close attention should be paid to the changes of cardiac function in patients with CLBBB after VSD closure, and the severity of such arrhythmia should be taken seriously and reexamined.
Collapse
Affiliation(s)
- Hongyan Zheng
- Department of Cardiology, Cardiovascular Institute of Panyu District, Panyu Central Hospital, No. 8 Fuyudong Rd, Guangzhou City, Guangdong Province 511400, China
| | - Aiwen Lin
- Department of Cardiology, Cardiovascular Institute of Panyu District, Panyu Central Hospital, No. 8 Fuyudong Rd, Guangzhou City, Guangdong Province 511400, China
| | - Li Wang
- Department of Obstetrics and Gynecology, Panyu Central Hospital, No. 8 Fuyudong Rd, Guangzhou City, Guangdong Province 511400, China
| | - Yukai Xu
- Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, No. 96 Dongchuan Rd, Guangzhou City, Guangdong Province 510100, China
| | - Zhiwei Zhang
- Department of Pediatric Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, No. 96 Dongchuan Rd, Guangzhou City, Guangdong Province 510100, China
| |
Collapse
|
5
|
Bergmann M, Germann CP, Nordmeyer J, Peters B, Berger F, Schubert S. Short- and Long-term Outcome After Interventional VSD Closure: A Single-Center Experience in Pediatric and Adult Patients. Pediatr Cardiol 2021; 42:78-88. [PMID: 33009919 PMCID: PMC7864847 DOI: 10.1007/s00246-020-02456-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 09/16/2020] [Indexed: 11/30/2022]
Abstract
Interventional closure of congenital ventricular septal defects (VSD) is recording a continuous rise in acceptance. Complete atrioventricular block (cAVB) and residual shunting are major concerns during follow-up, but long-term data for both are still limited. We retrospectively evaluated the outcome of patients with interventional VSD closure and focused on long-term results (> 1 year follow-up). Transcatheter VSD closures were performed between 1993 and 2015, in 149 patients requiring 155 procedures (104 perimembranous, 29 muscular, 19 residual post-surgical VSDs, and 3 with multiple defects). The following devices were used: 65 × Amplatzer™ Membranous VSD Occluder, 33 × Duct Occluder II, 27 × Muscular VSD Occluder, 3 × Duct Occluder I, 24 × PFM-Nit-Occlud®, and 3 × Rashkind-Occluder. The median age at time of implantation was 6.2 (0.01-66.1) years, median height 117 (49-188) cm, and median weight 20.9 (3.2-117) kg. Median follow-up time was 6.2 (1.1-21.3) years and closure rate was 86.2% at last follow-up. Complications resulting in device explantation include one case of cAVB with a Membranous VSD occluder 7 days after implantation and four cases due to residual shunt/malposition. Six (4%) deaths occurred during follow-up with only one procedural related death from a hybrid VSD closure. Overall, our reported results of interventional VSD closure show favorable outcomes with only one (0.7%) episode of cAVB. Interventional closure offers a good alternative to surgical closure and shows improved performance by using softer devices. However, prospective long-term data in the current era with different devices are still mandatory to assess the effectiveness and safety of this procedure.
Collapse
Affiliation(s)
- M. Bergmann
- grid.418209.60000 0001 0000 0404Department of Pediatric Cardiology and Congenital Heart Diseases, German Heart Center Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - C. P. Germann
- grid.418209.60000 0001 0000 0404Department of Pediatric Cardiology and Congenital Heart Diseases, German Heart Center Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - J. Nordmeyer
- grid.418209.60000 0001 0000 0404Department of Pediatric Cardiology and Congenital Heart Diseases, German Heart Center Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - B. Peters
- grid.418209.60000 0001 0000 0404Department of Pediatric Cardiology and Congenital Heart Diseases, German Heart Center Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - F. Berger
- grid.418209.60000 0001 0000 0404Department of Pediatric Cardiology and Congenital Heart Diseases, German Heart Center Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - S. Schubert
- grid.418209.60000 0001 0000 0404Department of Pediatric Cardiology and Congenital Heart Diseases, German Heart Center Berlin, Augustenburger Platz 1, 13353 Berlin, Germany ,grid.418457.b0000 0001 0723 8327Clinic for Pediatric Cardiology and Congenital Heart Defects, Herz- Und Diabeteszentrum NRW, Ruhr University of Bochum, Georgstraße 11, 32545 Bad Oeynhausen, Germany
| |
Collapse
|
6
|
Li G, Liao H, Wu J, Zhou K, Hua Y, Wang C, Duan H, Shi X, Wu G, Li Y. Re-evaluation of the criteria for asymmetric amplatzer occluders in the closure of perimembranous ventricular septal defects: A case series report. Medicine (Baltimore) 2020; 99:e21356. [PMID: 32846756 PMCID: PMC7447404 DOI: 10.1097/md.0000000000021356] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
RATIONALE To discuss suitable criteria for the application of asymmetric Amplatzer occluders for perimembranous ventricular septal defects (pmVSDs). PATIENTS CONCERNS AND DIAGNOSES We retrospectively studied 18 children with perimembranous VSDs who underwent attempted asymmetric occluder closure between January 2015 and December 2018 in our center. INTERVENTIONS Asymmetric Amplatzer occluders were attempted to be placed to all the enrolled patients. We analyzed the diameter of the defects with the receiver operating characteristic curve (ROC) values, the size of the occluders attempted, the presence of aneurysm and the presence of aortic valve prolapse for each patient. Then, for patients who experienced successful device implantation, the therapeutic efficiency was evaluated by follow-up. OUTCOMES Only 5 out of a total of 18 patients completed successful device implantation. Compared with failed cases, successful cases demonstrated a significantly smaller VSD size (5.46 ± 1.03 mm vs. 8.73 ± 2.33 mm, P = 0.012) and had a low ratio of aortic valvar prolapse (20% vs. 76.92%, P = 0.026). Four out of 5 successful cases involved arrhythmia complications, but the rhythm of the heart recovered after drug treatment. According to the ROC and Youden analyses, the cut-off value of the defect size for successful asymmetric Amplatzer occluder implantation was no larger than 5.7 mm. LESSONS The application of an asymmetric Amplatzer occluder expands the range of indications for patients with superior localized VSD but is largely limited in cases with aortic valvar prolapse and large VSD sizes. All successful cases recovered from arrhythmia postprocedure.
Collapse
Affiliation(s)
- Gang Li
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
- Department of Pediatrics, The Affiliated Hospital of Southwest Medical University, No. 25 Taiping Street, Luzhou, Sichuan, China
| | - Hongyu Liao
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Jinlin Wu
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Kaiyu Zhou
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Yimin Hua
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Chuan Wang
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Hongyu Duan
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Xiaoqing Shi
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Gang Wu
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| | - Yifei Li
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan
| |
Collapse
|
7
|
Haddad RN, Daou L, Saliba Z. Device Closure of Perimembranous Ventricular Septal Defect: Choosing Between Amplatzer Occluders. Front Pediatr 2019; 7:300. [PMID: 31475122 PMCID: PMC6707042 DOI: 10.3389/fped.2019.00300] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Accepted: 07/08/2019] [Indexed: 11/13/2022] Open
Abstract
Background: Off-label device closure of perimembranous ventricular septal defect (pmVSD) is well reported in the literature with encouraging results. However, technical challenges may be encountered. Objectives: To evaluate and compare feasibility, technical aspects, procedural outcomes, and mid-term follow-up of pmVSD closure using Amplatzer™ occluders. Patients and Methods: From July 2015 to July 2018, patients in whom pmVSD closure was attempted using an Amplatzer occluder were retrospectively identified from our institution's database. Device selection was made according to the defect anatomy that was obtained via ventriculography and trans-esophageal echocardiography. Follow-up evaluations were done at discharge, then at 1, 3, 6, and 12 months and yearly thereafter with transthoracic echocardiography and electrocardiogram. Results: In total, 8 Amplatzer Duct Occluder (ADO), 27 ADO II, and 17 Amplatzer Muscular VSD Occluder (AMO) were used in 51 patients with a mean age of 7.4 ± 6.9 years and a mean weight of 25.4 ± 19.8 kg. Implantation was successful in 50/51 patients (98.0%). There was no procedure related mortality. One ADO accidentally embolized to the aorta after release and was surgically recaptured from the iliac artery. All ADO II were delivered retrogradely with the least amount of time (p = 0.002) and the lowest radiation exposure (p < 0.001). Minor valvular disturbances occurred in 8/49 patients (16.3%), including five tricuspid regurgitation (three with ADOII and two with AMO) and three trivial aortic regurgitations (two with ADO and one with ADOII). On a median follow-up of 194 days (range, 60-895 days), no surgical device removal was necessary. At 6 months of follow-up, trivial residual shunt was present in 5/49 patients (10.2%), among which none occurred with ADO. One complete atrioventricular block was detected 18 months after ADO implantation and required permanent pacing. Conclusions: Transcatheter closure of PmVSD using Amplatzer occluders is feasible, safe and efficacious in properly selected patients. The major key factor behind high procedural success rate is proper device selection. ADOII is remarkably superior in terms of device softness, flexibility and faster implantation process. Yet, its use is limited to small defects with particular anatomy.
Collapse
Affiliation(s)
- Raymond N Haddad
- Department of Pediatrics, Hotel Dieu de France University Medical Center, Saint Joseph University, Beirut, Lebanon
| | - Linda Daou
- Department of Pediatric Cardiology, Hotel Dieu de France University Medical Center, Saint Joseph University, Beirut, Lebanon
| | - Zakhia Saliba
- Department of Pediatric Cardiology, Hotel Dieu de France University Medical Center, Saint Joseph University, Beirut, Lebanon
| |
Collapse
|
8
|
Nguyen HL, Phan QT, Doan DD, Dinh LH, Tran HB, Sharmin S, Thottian JJ, Won H, Lee WS, Shin SY, Nguyen TQ, Kim SW. Percutaneous closure of perimembranous ventricular septal defect using patent ductus arteriosus occluders. PLoS One 2018; 13:e0206535. [PMID: 30439981 PMCID: PMC6237304 DOI: 10.1371/journal.pone.0206535] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Accepted: 10/15/2018] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES To assess the safety and efficacy of percutaneous closure of perimembranous ventricular septal defect (PmVSD) using patent ductus arteriosus (PDA) occluders. BACKGROUND Widespread use of conventional PmVSD closure devices has been limited by unacceptable high rate of complete heart block (CHB). The elegant design of PDA occluders is supposed to ease implantation, increase closure rate and minimize damage to adjacent structures. Thus, PDA occluders may reduce complications, especially the CHB, and offer a good alternative for PmVSD closure. METHOD From September 2008 to October 2015, patients who underwent attempted percutaneous VSD closure using PDA occluders were included in the study. Patient demographics, echocardiography measurements, procedure details and follow-up data until October 2017 were collected. RESULTS In total, 321 patients with a mean age of 15.5±12.6 years and mean a weight of 33.3±20.5 kg were included in this study. The mean defect size was 4.8±2.1 mm. Implantation was successful in 307 (95.6%) patients. The median follow-up time was 63 months (24 to 108 months). The closure rates were 89.5%, 91.5%, and 99.3% after the procedure 24 hours, 6 months and 2 years, respectively. Major complications occurred in 5 (1.7%) patients during the procedure and follow-up, including persistent CHB in 2 (0.7%) patients and device embolization in 3 (1.0%) patients. No death, disability, or other major complication was detected. CONCLUSION Percutaneous closure of PmVSD using PDA occluders is feasible, safe and efficacious in selected patients.
Collapse
Affiliation(s)
- Hieu Lan Nguyen
- Intervention Center, Vietnam National Heart Institute, Ha Noi, Vietnam
- Intervention Center, Hanoi Medical University Hospital, Hanoi, Vietnam
| | - Quang Tan Phan
- Intervention Center, Quang Nam Central General Hospital, Quang Nam, Vietnam
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
- * E-mail:
| | - Dung Duc Doan
- Intervention Center, Hanoi Medical University Hospital, Hanoi, Vietnam
| | - Linh Huynh Dinh
- Intervention Center, Vietnam National Heart Institute, Ha Noi, Vietnam
| | - Hieu Ba Tran
- Intervention Center, Vietnam National Heart Institute, Ha Noi, Vietnam
| | - Saima Sharmin
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| | - Julian Johny Thottian
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
- Intervention Center, Westfort Group Hospital, Kerala, India
| | - Hoyoun Won
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| | - Wang Soo Lee
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| | - Seung Yong Shin
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| | | | - Sang Wook Kim
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| |
Collapse
|
9
|
Park H, Song J, Kim ES, Huh J, Kang IS. Early Experiences Using Cocoon Occluders for Closure of a Ventricular Septal Defect. J Cardiovasc Imaging 2018; 26:165-174. [PMID: 30310884 PMCID: PMC6160808 DOI: 10.4250/jcvi.2018.26.e19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 09/04/2018] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Transcatheter device closure of ventricular septal defect (VSD) has become an attractive alternative to surgery. We report here on our early experiences of transcatheter closure of VSD using Cocoon devices, which are now available in Korea. METHODS We reviewed the medical records and angiographic images of 13 patients who underwent transcatheter closure of VSD with a Cocoon occluder at Samsung Medical Center. The median patient age was 5.8 years, and the median patient weight was 20.3 kg. RESULTS The device was successfully implanted in all patients. The follow-up period was 10 ± 6 months, and no mortality was observed. An immediate residual leak on the next day was detected in 7 patients (including 4 with perimembranous VSD). However, 6 months later, a residual leak was observed only in 2 patients with perimembranous VSD and 1 patient with muscular VSD. Early conduction abnormalities were observed in 3 patients, all of whom had perimembranous VSD, but no significant complete atrioventricular block was observed. One patient experienced newly developed significant aortic regurgitation that decreased spontaneously but still existed at the 6 month follow-up. No hemolysis or embolization was noted on the next day or during the follow-up period. CONCLUSIONS Cocoon devices can be used safely and effectively for VSD closure. However, residual leaks and conduction abnormalities may occur early after implantation, especially in patients with perimembranous VSD. Although normal conduction was recovered, long-term evaluation remains essential.
Collapse
Affiliation(s)
- Hyojung Park
- Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jinyoung Song
- Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - E Seul Kim
- Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - June Huh
- Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - I-Seok Kang
- Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
10
|
Nguyen HL, Phan QT, Dinh LH, Tran HB, Won H, Thottian JJ, Duc DD, Quang TN, Kim SW. Nit-Occlud Lê VSD coil versus Duct Occluders for percutaneous perimembranous ventricular septal defect closure. CONGENIT HEART DIS 2018; 13:584-593. [PMID: 30019378 DOI: 10.1111/chd.12613] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2017] [Revised: 03/06/2018] [Accepted: 04/19/2018] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate the efficacy and safety of Nit-Occlud Lê VSD Coil versus Duct Occluders for percutaneous closure of perimembranous ventricular septal defect (pmVSD). INTRODUCTION VSD closure using conventional pmVSD occluders has been largely abandoned because of an unacceptable high rate of complete heart block (CHB). The advantages of Duct Occluders and VSD Coil are supposed to reduce the drawbacks of previous devices, especially CHB complications. METHOD Patients underwent percutaneous pmVSD closure were divided into Coil group (using VSD Coil, n = 71) and DO group (using Duct Occluders, n = 315). Patient demographics, clinical presentations, echocardiography measurements, procedure details and follow-up data were collected. RESULT The procedure success rate was high in both DO group (95.6%) and Coil group (97.2%, P = .53). The closure rate immediately after procedure in the DO group was higher than that in the Coil group (76.8% vs. 58.0%, P < .01). After 6 months, the closure rate was not significantly different between the 2 groups (DO group 91.3% vs. Coil group 84.1%, P = .07). The mean follow-up time was 61.4 ± 24.1 months. The major complication rate was low in both groups (DO group 1.9% vs. Coil group 1.4%, P = .78). Two patients (0.7%) in the DO group and one patient (1.4%) in the Coil group with CHB needed permanent pacemaker (P = .5). Device embolization (3 patients, 1.0%) and endocarditis (1 patient, 0.3%) occurred only in the DO group. There was no death, disability or other major complications detected in either group. CONCLUSION Percutaneous pmVSD closure using either Nit-Occlud Lê VSD Coil or Duct Occluders is feasible, safe and efficacious in selected patients. The main problems of Duct Occluders are unsuitable defect anatomy and device embolization while VSD Coil disadvantages are residual shunt and hemolysis.
Collapse
Affiliation(s)
- Hieu Lan Nguyen
- Intervention Center, Hanoi Medical University Hospital, Hanoi, Vietnam.,Intervention Center, Vietnam National Heart Institute, Hanoi, Vietnam
| | - Quang Tan Phan
- Intervention Center, Quang Nam Central General Hospital, Quang Nam, Vietnam.,Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| | - Linh Huynh Dinh
- Intervention Center, Vietnam National Heart Institute, Hanoi, Vietnam
| | - Hieu Ba Tran
- Intervention Center, Vietnam National Heart Institute, Hanoi, Vietnam
| | - Hoyoun Won
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| | - Julian Johny Thottian
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea.,Westfort Group Hospital, Intervention Center, Kerala, India
| | - Dung Doan Duc
- Intervention Center, Hanoi Medical University Hospital, Hanoi, Vietnam
| | | | - Sang Wook Kim
- Intervention Center, Chung-Ang University Hospital, Seoul, South Korea
| |
Collapse
|
11
|
A meta-analysis of transcatheter device closure of perimembranous ventricular septal defect. Int J Cardiol 2018; 254:75-83. [DOI: 10.1016/j.ijcard.2017.12.011] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2017] [Accepted: 12/05/2017] [Indexed: 11/21/2022]
|
12
|
Li Y, Zhou K, Hua Y. Whether heart blocks post perimembranous ventricular septal defect device closure remain threatening: how could Chinese experiences impact the world? J Evid Based Med 2017; 10:5-10. [PMID: 27481182 DOI: 10.1111/jebm.12214] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Accepted: 06/24/2016] [Indexed: 01/11/2023]
Abstract
Transcatheter closure has become one of the alternations of surgical treatment since 1988. However, cAVB occurred as a threatening incidence of 6.8% after Amplatzer VSD Occluder closure, which was quite higher than the incidence of 1% to 2% post-surgical closure, which leaded this kind of technique, was not approved by FDA. In this commentary, we reviewed the publications of cAVB following the device closure, and summarized current data of Modified Amplatzer-type Occluder during long-term follow-up, especially introduced the experiences from China, where this kind of treatment became a routine procedure for VSD children. Moreover, we carried our visualized analysis based on scientific literatures using CiteSpace to draw knowledge burst mapping, which revealed the development procedure on this interested topics, and demonstrated the role of China's works to make contributions in the field, and figured out the limitation of our researches, which supplied a basic understanding on why we could not impact the world. Finally, it concluded that transcatheter closure of pmVSD with Modified Amplatzer-type Occluder would be safe and efficient with low incidence of well controlled complications, but it failed to spread our experiences in a more scientific way. And, we hope this kind of therapy could be accepted in a wider region of the world with the increasing evidence from China.
Collapse
Affiliation(s)
- Yifei Li
- Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, China
- Ministry of Education Key Laboratory of Women and Children's Diseases and Birth Defects, West China Second University Hospital, Sichuan University, Chengdu, China
| | - Kaiyu Zhou
- Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, China
- Ministry of Education Key Laboratory of Women and Children's Diseases and Birth Defects, West China Second University Hospital, Sichuan University, Chengdu, China
- Program for Changjiang Scholars and Innovative Research Team in University, West China Second University Hospital, Sichuan University, Chengdu, China
| | - Yimin Hua
- Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, China
- Ministry of Education Key Laboratory of Women and Children's Diseases and Birth Defects, West China Second University Hospital, Sichuan University, Chengdu, China
- Program for Changjiang Scholars and Innovative Research Team in University, West China Second University Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
13
|
Wang L, Shang X, Qiu Q, Lu R, Xiao S, Li D, Yu J, Zhang C, Xia C, Zhou H, Zhang G. Late-Onset Postoperative Junctional Ectopic Tachycardia in Nonsurgical Procedures. Int Heart J 2016; 57:522-4. [PMID: 27385605 DOI: 10.1536/ihj.15-509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Postoperative junctional ectopic tachycardia (JET) is a narrow complex tachycardia and most frequently occurs during and after surgical repair of certain types of congenital heart defects. Postoperative junctional ectopic tachycardia may produce unfavorable hemodynamics that prolongs stays in the cardiac intensive care unit and hospital, prolongs time on a ventilator, and occasionally requires the use of extracorporeal membrane oxygenation (ECMO) as rescue therapy. The present report describes a rare case of late-onset postoperative junctional ectopic tachycardia, which occurred 13 days after the deployment of a perimembranous ventricular septal defect (PmVSD) occluder in a 17-year-old female teenager. To the best of our knowledge, late-onset postoperative junctional ectopic tachycardia has not previously been reported as a complication in nonsurgical procedures. In this case, the junctional ectopic tachycardia remained resistant to medicines and the haemodynamic imbalance caused a serious life-threatening situation in the patient. The occluder was removed by an emergent thoracotomy; then, the patient was successfully cured by being supported with extracorporeal membrane oxygenation. The findings suggest that during follow-up management, the physician should pay attention postoperatively to junctional ectopic tachycardia even after discharge from the hospital.
Collapse
Affiliation(s)
- Lijun Wang
- Cardiac Dynamics Laboratory, Wuhan Asia Heart Hospital
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Hornung M, Franke J, Id D, Sievert H. [Interventional closure of atrial septal defects, patent oval foramen and ventricular septal defects]. Herz 2016; 40:765-70. [PMID: 26135465 DOI: 10.1007/s00059-015-4331-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Percutaneous transcatheter closure techniques and devices for congenital intracardiac shunts have considerably improved; therefore, catheter closure is now the treatment of choice for atrial septal defects (ASD). This is technically feasible in more than 80% of patients with a secundum ASD and the success rate is higher than 99%. General anesthesia is as a rule unnecessary and the hospital stay is very short. A patent oval foramen (POF) is a potential cause of cryptogenic stroke and peripheral embolisms. The catheter occlusion has many advantages in comparison to lifelong anticoagulation therapy and for some patients it is the only therapeutic option. Randomized trials have shown that interventional closure leads to results which are comparable to drug therapy and for some occlusion systems even evidence of significant advantages compared to drug therapy was found. Even ventricular septal defects (VSD), including perimembraneous and post-myocardial infarction VSDs can be closed by catheter techniques with a high success rate.
Collapse
Affiliation(s)
- Marius Hornung
- CardioVasculäres Centrum CVC, Seckbacher Landstraße 65, 60389, Frankfurt, Deutschland
| | | | | | | |
Collapse
|
15
|
Transcatheter device closure of perimembranous ventricular septal defect in children treated with prophylactic oral steroids: acute and mid-term results of a single-centre, prospective, observational study. Cardiol Young 2016; 26:669-76. [PMID: 26105182 DOI: 10.1017/s1047951115001018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
UNLABELLED Background and Objective Although transcatheter closure of perimembranous ventricular septal defect is emerging as an accepted, viable alternative, conduction disturbances still remain a major concern. Although steroid treatment has shown encouraging results with complete recovery, efficacy of prophylactic use of steroids is still speculative. We aim to study the mid-term outcome of perimembranous ventricular septal defect closure in children who received prophylactic oral steroids. Materials and methods A prospective study was designed and antegrade device closure was attempted in eligible children who met the following inclusion criteria: age 3-18 years and weight >10 kg, defect diameter ⩽12 mm, and symptomatic, haemodynamic changes or history of infective endocarditis. Prophylactic steroid protocol consisted of 2 weeks oral prednisolone (1 mg/kg/day) initiated immediately after the procedure, and in the event of bradyarrhythmia it was escalated to 2 mg/kg. Patients were regularly followed-up at 1, 6, and 12 months and then annually. Patients with post-procedure heart block underwent Holter monitoring after a minimum of 1 year interval. RESULTS Between May, 2007 and August, 2012, successful device closure was accomplished in 290/297 patients. Mean age and weight were 9±3.12 years and 21±8.27 kg, respectively. The defect measured 5±1.38 mm on echocardiography. Mean fluoroscopy time was 12.98±8.64 minutes. Eight patients with major complications included one each with device embolisation, haemolysis, severe aortic regurgitation, and five with bradyarrhythmias, including complete atrioventricular block in three, Mobitz II in one, and bifascicular block in one. Patients with complete atrioventricular block responded to high-dose steroid and temporary pacemaker. Minor complications included post-procedure heart block (n=22) and blood loss (n=2). At 18.23±13.15 months follow-up, 8/27 (five major, 22 minor) with arrhythmia had persistent post-procedure heart block of no clinical consequences. CONCLUSION In our patient population, transcatheter device closure of the perimembranous ventricular septal defect with prophylactic oral steroid resulted in excellent closure rate and acceptably low incidence of conduction disturbances at mid-term follow-up.
Collapse
|
16
|
Chen F, Li P, Liu S, Du H, Zhang B, Jin X, Zheng X, Wu H, Chen S, Han L, Qin Y, Zhao X. Transcatheter Closure of Intracristal Ventricular Septal Defect With Mild Aortic Cusp Prolapse Using Zero Eccentricity Ventricular Septal Defect Occluder. Circ J 2015; 79:2162-8. [DOI: 10.1253/circj.cj-15-0301] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Feng Chen
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Pan Li
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Suxuan Liu
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - He Du
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Bili Zhang
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Xiucai Jin
- Department of Echocardiography, Changhai Hospital, Second Military Medical University
| | - Xing Zheng
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Hong Wu
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Shaoping Chen
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Lin Han
- Department of Cardiothoracic Surgery, Changhai Hospital, Second Military Medical University
| | - Yongwen Qin
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| | - Xianxian Zhao
- Department of Cardiology, Changhai Hospital, Second Military Medical University
| |
Collapse
|
17
|
Xing Q, Wu Q, Shi L, Xing Y, Yu G. Minimally invasive transthoracic device closure of isolated ventricular septal defects without cardiopulmonary bypass: Long-term follow-up results. J Thorac Cardiovasc Surg 2015; 149:257-64. [DOI: 10.1016/j.jtcvs.2014.07.078] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2014] [Revised: 06/24/2014] [Accepted: 07/20/2014] [Indexed: 11/26/2022]
|
18
|
Decreased tricuspid regurgitation following percutaneous closure of congenital perimembranous ventricular septal defect: immediate and 6-month echocardiographic assessment. Heart Vessels 2014; 30:611-7. [PMID: 24946869 DOI: 10.1007/s00380-014-0531-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2013] [Accepted: 05/23/2014] [Indexed: 01/26/2023]
Abstract
As a common concomitant performance and the most frequent complications of transcatheter perimembranous ventricular septal defect (VSD) closure, tricuspid regurgitation (TR) has rarely been concerned. From January 2008 to December 2012, a total of 70 patients (men: 33, women: 37; mean age: 30.0 ± 17.1 years) with at least mild TR before VSD closure were examined in 508 consecutive congenital perimembranous VSD patients to investigate the outcomes of TR. After VSD closure, the jet area decreased from 3.4 ± 2.5 to 1.2 ± 2.5 cm(2) (p < 0.001); however, no significant decrease was found in 3 patients (mean age 59.7 ± 2.5 years) with severe TR (12.0 ± 1.2 versus 11.2 ± 3.2 cm(2), p = 0.668). Compared to the early outcome after VSD closure, the jet area detected by TTE at 6-month follow-up had further decreased (1.2 ± 2.5 versus 0.9 ± 2.2 cm(2), p < 0.001). In 6 patients, a slight residual shunt was detected immediately after VSD closure and diminished in 3 patients at 6-month follow-up. The hemolysis occurred in one of these six patients and recovered after 3 days. In conclusion, functional TR was ameliorated after percutaneous VSD closure, although persistent abundant TR was common in patients with severe TR before procedure.
Collapse
|
19
|
Ventricular arrhythmias induced by long-term use of ephedrine in two competitive athletes. Heart Vessels 2014; 30:280-3. [DOI: 10.1007/s00380-013-0455-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2013] [Accepted: 12/13/2013] [Indexed: 10/25/2022]
|