1
|
Głuchowska A, Cysewski D, Baj-Krzyworzeka M, Szatanek R, Węglarczyk K, Podszywałow-Bartnicka P, Sunderland P, Kozłowska E, Śliwińska MA, Dąbrowski M, Sikora E, Mosieniak G. Unbiased proteomic analysis of extracellular vesicles secreted by senescent human vascular smooth muscle cells reveals their ability to modulate immune cell functions. GeroScience 2022; 44:2863-2884. [PMID: 35900662 PMCID: PMC9768090 DOI: 10.1007/s11357-022-00625-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 07/12/2022] [Indexed: 01/07/2023] Open
Abstract
Atherosclerosis, a common age-related disease, is characterized by intense immunological activity. Atherosclerotic plaque is composed of endothelial cells, vascular smooth muscle cells (VSMCs), lipids and immune cells infiltrating from the blood. During progression of the disease, VSMCs undergo senescence within the plaque and secrete SASP (senescence-associated secretory phenotype) factors that can actively modulate plaque microenvironment. We demonstrated that senescent VSMCs secrete increased number of extracellular vesicles (senEVs). Based on unbiased proteomic analysis of VMSC-derived EVs and of the soluble fraction of SASP (sSASP), more than 900 proteins were identified in each of SASP compartments. Comparison of the composition of VMSC-derived EVs with the SASP atlas revealed several proteins, including Serpin Family F Member 1 (SERPINF1) and Thrombospondin 1 (THBS1), as commonly upregulated components of EVs secreted by senescent VSMCs and fibroblasts. Among soluble SASP factors, only Growth Differentiation Factor 15 (GDF15) was universally increased in the secretome of senescent VSMCs, fibroblasts, and epithelial cells. Bioinformatics analysis of EV proteins distinguished functionally organized protein networks involved in immune cell function regulation. Accordingly, EVs released by senescent VSMCs induced secretion of IL-17, INFγ, and IL-10 by T cells and of TNFα produced by monocytes. Moreover senEVs influenced differentiation of monocytes favoring mix M1/M2 polarization with proinflammatory characteristics. Altogether, our studies provide a complex, unbiased analysis of VSMC SASP and prove that EVs derived from senescent VSMCs influence the cytokine milieu by modulating immune cell activity. Our results strengthen the role of senescent cells as an important inducer of inflammation in atherosclerosis.
Collapse
Affiliation(s)
- Agata Głuchowska
- Laboratory of Molecular Bases of Aging, Nencki Institute of Experimental Biology, Polish Academy of Sciences, Pasteura 3 St., 02-093, Warsaw, Poland
| | - Dominik Cysewski
- Mass Spectrometry Laboratory, Institute of Biochemistry and Biophysics, Polish Academy of Sciences, Warsaw, Poland
- Clinical Research Centre, Medical University of Bialystok, Białystok, Poland
| | - Monika Baj-Krzyworzeka
- Department of Clinical Immunology, Institute of Pediatrics, Jagiellonian University Medical College, Krakow, Poland
| | - Rafał Szatanek
- Department of Clinical Immunology, Institute of Pediatrics, Jagiellonian University Medical College, Krakow, Poland
| | - Kazimierz Węglarczyk
- Department of Clinical Immunology, Institute of Pediatrics, Jagiellonian University Medical College, Krakow, Poland
| | | | - Piotr Sunderland
- Laboratory of Molecular Bases of Aging, Nencki Institute of Experimental Biology, Polish Academy of Sciences, Pasteura 3 St., 02-093, Warsaw, Poland
| | - Ewa Kozłowska
- Department of Immunology, Institute of Functional Biology and Ecology, Faculty of Biology University of Warsaw, Warsaw, Poland
| | - Małgorzata A Śliwińska
- Laboratory of Imaging Tissue Structure and Function, Nencki Institute of Experimental Biology Polish Academy of Sciences, Warsaw, Poland
| | - Michał Dąbrowski
- Laboratory of Bioinformatics, Neurobiology Centre, Nencki Institute of Experimental Biology of Polish Academy of Sciences, Warsaw, Poland
| | - Ewa Sikora
- Laboratory of Molecular Bases of Aging, Nencki Institute of Experimental Biology, Polish Academy of Sciences, Pasteura 3 St., 02-093, Warsaw, Poland
| | - Grażyna Mosieniak
- Laboratory of Molecular Bases of Aging, Nencki Institute of Experimental Biology, Polish Academy of Sciences, Pasteura 3 St., 02-093, Warsaw, Poland.
| |
Collapse
|
2
|
Ouyang H, Zeng X, Zhang C, Song L, Xu J, Hou Z, Xie S, Tao Z, He J. A meta-analysis of everolimus-eluting stents versus sirolimus-eluting stents and paclitaxel-eluting stents in diabetic patients. J Cardiothorac Surg 2021; 16:90. [PMID: 33865413 PMCID: PMC8052784 DOI: 10.1186/s13019-021-01452-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 03/31/2021] [Indexed: 11/10/2022] Open
Abstract
Objective We performed this meta-analysis to determine which stent among everolimus eluting stents (EES), sirolimus eluting stents (SES) and paclitaxel eluting stents (PES) should be preferred for the treatment of DM patients. Methods A systematic search of publications about randomized controlled trials (RCTs) focused on diabetic patients received EES, SES or PES was conducted. We evaluated the following indicators: target vessel revascularization (TVR), target lesion revascularization (TLR), late luminal loss (LLL), stent thrombosis (ST), myocardial infarction (MI), all-cause mortality and cardiac mortality. Results EES showed obvious advantages over SES for DM patients, as it induced the lowest rate of target vessel revascularization and target lesion revascularization (TLR) (p = 0.04). In addition, EES induced lower in-segment LLL than PSE and SES and lower in-stent LLL than PES in DM patients (all p < 0.05). Moreover, EES effectively reduced all-cause mortality compared to SES (RR = 0.71, 95% CI: 0.52–0.99, p = 0.04) and MI rates compared to PES (RR = 0.44, 95% CI: 0.26–0.73, p = 0.0002). Furthermore, EES could reduce the ST rate compared with both SES (RR = 0.53, 95% CI: 0.28–0.98, p = 0.04) and PES (RR = 0.18, 95% CI: 0.07–0.51, p = 0.001). Conclusion Among those three types of stents, EES should be the first recommended stent for DM patients.
Collapse
Affiliation(s)
- Hang Ouyang
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China
| | - Xuehui Zeng
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China
| | - Chunlei Zhang
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China
| | - Linli Song
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China
| | - Jiarui Xu
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China
| | - Zhihui Hou
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China
| | - Siya Xie
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China
| | - Zheng Tao
- Department of Vascular Surgery, Affiliated Hospital of Jiangsu University, 438 Jiefang Road, Zhenjiang, Jiangsu, 212001, People's Republic of China.
| | - Jincai He
- Department of Clinical Laboratory, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, 1 Fuhua Road, Shenzhen, Guangdong, 518033, People's Republic of China.
| |
Collapse
|
3
|
Coronary microembolization and microvascular dysfunction. Int J Cardiol 2018; 258:17-23. [PMID: 29429637 DOI: 10.1016/j.ijcard.2018.02.010] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 02/02/2018] [Accepted: 02/02/2018] [Indexed: 01/16/2023]
Abstract
Plaque erosion, fissuring or rupture occurs spontaneously or during coronary interventions. At some residual blood flow, the atherothrombotic debris is washed into the coronary microcirculation, causing physical obstruction, vasoconstriction, inflammation and ultimately microinfarction. Coronary microembolization also contributes to microvascular obstruction in reperfused acute myocardial infarction. Patients with microvascular obstruction after reperfused myocardial infarction have worse prognosis. Cardioprotective strategies to avoid acute coronary microembolization and rescue myocardium from microvascular obstruction have not yet been established in clinical practice. Subclinical coronary microembolization together with release of thrombogenic, vasoconstrictor and inflammatory substances from a culprit lesion can sensitize the coronary microcirculation and contribute to angina in the absence of major epicardial coronary obstruction. Repetitive coronary microembolization can induce progressive loss of functional cardiomyocytes and induce heart failure in the absence of overt myocardial infarction.
Collapse
|
4
|
Lieder HR, Baars T, Kahlert P, Kleinbongard P. Aspirate from human stented saphenous vein grafts induces epicardial coronary vasoconstriction and impairs perfusion and left ventricular function in rat bioassay hearts with pharmacologically induced endothelial dysfunction. Physiol Rep 2017; 4:4/15/e12874. [PMID: 27482071 PMCID: PMC4985543 DOI: 10.14814/phy2.12874] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 07/01/2016] [Indexed: 12/17/2022] Open
Abstract
Stent implantation into aortocoronary saphenous vein grafts (SVG) releases particulate debris and soluble vasoactive mediators, for example, serotonin. We now analyzed effects of the soluble mediators released into the coronary arterial blood during stent implantation on vasomotion of isolated rat epicardial coronary artery segments and on coronary flow and left ventricular developed pressure in isolated perfused rat hearts. Coronary blood was retrieved during percutaneous SVG intervention using a distal occlusion/aspiration protection device in nine symptomatic patients with stable angina pectoris and a flow‐limiting SVG stenosis. The blood was separated into particulate debris and plasma. Responses to coronary plasma were determined in isolated rat epicardial coronary arteries and in isolated, constant pressure‐perfused rat hearts (±nitric oxide synthase [NOS] inhibition and ±serotonin receptor blockade, respectively). Coronary aspirate plasma taken after stent implantation induced a stronger vasoconstriction of rat epicardial coronary arteries (52 ± 8% of maximal potassium chloride induced vasoconstriction [% KClmax = 100%]) than plasma taken before stent implantation (12 ± 8% of KClmax); NOS inhibition augmented this vasoconstrictor response (to 110 ± 15% and 24 ± 9% of KClmax). Coronary aspirate plasma taken after stent implantation reduced in isolated perfused rat hearts only under NOS inhibition coronary flow by 17 ± 3% and left ventricular developed pressure by 25 ± 4%. Blockade of serotonin receptors abrogated these effects. Coronary aspirate plasma taken after stent implantation induces vasoconstriction in isolated rat epicardial coronary arteries and reduces coronary flow and left ventricular developed pressure in isolated perfused rat hearts with pharmacologically induced endothelial dysfunction.
Collapse
Affiliation(s)
- Helmut R Lieder
- Institut für Pathophysiologie, Universitätsklinikum Essen Westdeutsches Herz- und Gefäßzentrum, Essen, Germany
| | - Theodor Baars
- Klinik für Kardiologie, Universitätsklinikum Essen Westdeutsches Herz- und Gefäßzentrum, Essen, Germany
| | - Philipp Kahlert
- Klinik für Kardiologie, Universitätsklinikum Essen Westdeutsches Herz- und Gefäßzentrum, Essen, Germany
| | - Petra Kleinbongard
- Institut für Pathophysiologie, Universitätsklinikum Essen Westdeutsches Herz- und Gefäßzentrum, Essen, Germany
| |
Collapse
|
5
|
Baars T, Kahlert P, Baars A, Preibsch H, Rassaf T, Heusch G, Kleinbongard P. Influence of stent implantation on erythrocyte aggregation in human native coronary arteries and saphenous vein grafts. Microcirculation 2016; 23:637-645. [PMID: 27736045 DOI: 10.1111/micc.12326] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Accepted: 10/09/2016] [Indexed: 11/27/2022]
Affiliation(s)
- Theodor Baars
- Institute for Pathophysiology; West German Heart and Vascular Centre Essen; University of Essen Medical School; Essen Germany
- Institute for Clinic of Cardiology; West German Heart and Vascular Centre Essen; University of Essen Medical School; Essen Germany
| | - Philipp Kahlert
- Institute for Clinic of Cardiology; West German Heart and Vascular Centre Essen; University of Essen Medical School; Essen Germany
| | - Albert Baars
- Department of Biomimetics; Hochschule of Bremen; City University of Applied Science; Bremen Germany
| | - Heike Preibsch
- Diagnostic and Interventional Radiology; University Hospital Tuebingen; Tuebingen Germany
| | - Tienush Rassaf
- Institute for Clinic of Cardiology; West German Heart and Vascular Centre Essen; University of Essen Medical School; Essen Germany
| | - Gerd Heusch
- Institute for Pathophysiology; West German Heart and Vascular Centre Essen; University of Essen Medical School; Essen Germany
| | - Petra Kleinbongard
- Institute for Pathophysiology; West German Heart and Vascular Centre Essen; University of Essen Medical School; Essen Germany
| |
Collapse
|
6
|
Horn P, Baars T, Kahlert P, Heiss C, Westenfeld R, Kelm M, Erbel R, Heusch G, Kleinbongard P. Release of Intracoronary Microparticles during Stent Implantation into Stable Atherosclerotic Lesions under Protection with an Aspiration Device. PLoS One 2015; 10:e0124904. [PMID: 25915510 PMCID: PMC4411166 DOI: 10.1371/journal.pone.0124904] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Accepted: 03/06/2015] [Indexed: 01/21/2023] Open
Abstract
OBJECTIVE Stent implantation into atherosclerotic coronary vessels impacts on downstream microvascular function and induces the release of particulate debris and soluble substances, which differs qualitatively and quantitatively between native right coronary arteries (RCAs) and saphenous vein grafts on right coronary arteries (SVG-RCAs). We have now quantified the release of microparticles (MPs) during stent implantation into stable atherosclerotic lesions and compared the release between RCAs and SVG-RCAs. METHODS In symptomatic, male patients with stable angina and a stenosis in their RCA or SVG-RCA, respectively (n = 14/14), plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Coronary aspirate was retrieved during stent implantation with a distal occlusion/aspiration device and divided into particulate debris and plasma. Particulate debris was weighed. Platelet-derived MPs (PMPs) were distinguished by flow cytometry as CD41+, endothelium-derived MPs (EMPs) as CD144+, CD62E+ and CD31+/CD41-, leukocyte-derived MPs as CD45+, and erythrocyte-derived MPs as CD235+. RESULTS In patients with comparable plaque volume and composition in RCAs and SVG-RCAs, intracoronary PMPs and EMPs were increased after stent implantation into their RCAs and SVG-RCAs (CD41+: 2729.6 ± 645.6 vs. 4208.7 ± 679.4 and 2355.9 ± 503.9 vs. 3285.8 ± 733.2 nr/µL; CD144+: 451.5 ± 87.9 vs. 861.7 ± 147.0 and 444.6 ± 74.8 vs. 726.5 ± 136.4 nr/µL; CD62E+: 1404.1 ± 247.7 vs. 1844.3 ± 378.6 and 1084.6 ± 211.0 vs. 1783.8 ± 384.3 nr/µL, P < 0.05), but not different between RCAs and SVG-RCAs. CONCLUSION Stenting in stable atherosclerotic lesions is associated with a substantial release not only of PMPs, but also of EMPs in RCAs and SVG-RCAs. Their release does not differ between RCAs and SVG-RCAs. TRIAL REGISTRATION ClinicalTrials.gov NCT01430884.
Collapse
Affiliation(s)
- Patrick Horn
- Division of Cardiology, Pulmonology, and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany
| | - Theodor Baars
- Institute for Pathophysiology, West German Heart and Vascular Centre Essen, University of Essen Medical School, Essen, Germany
- Clinic for Cardiology, West German Heart and Vascular Centre Essen, University of Essen Medical School, Essen, Germany
| | - Philipp Kahlert
- Clinic for Cardiology, West German Heart and Vascular Centre Essen, University of Essen Medical School, Essen, Germany
| | - Christian Heiss
- Division of Cardiology, Pulmonology, and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany
| | - Ralf Westenfeld
- Division of Cardiology, Pulmonology, and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany
| | - Malte Kelm
- Division of Cardiology, Pulmonology, and Vascular Medicine, Medical Faculty, University Duesseldorf, Duesseldorf, Germany
| | - Raimund Erbel
- Clinic for Cardiology, West German Heart and Vascular Centre Essen, University of Essen Medical School, Essen, Germany
| | - Gerd Heusch
- Institute for Pathophysiology, West German Heart and Vascular Centre Essen, University of Essen Medical School, Essen, Germany
| | - Petra Kleinbongard
- Institute for Pathophysiology, West German Heart and Vascular Centre Essen, University of Essen Medical School, Essen, Germany
- * E-mail:
| |
Collapse
|
7
|
Wu G, Sun G, Zhao R, Sun M. Clinical outcomes of second- versus first-generation drug-eluting stents in patients with acute myocardial infarction: a meta-analysis of randomized controlled trials. Arch Med Sci 2014; 10:643-50. [PMID: 25276146 PMCID: PMC4175765 DOI: 10.5114/aoms.2014.44855] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2013] [Revised: 09/20/2013] [Accepted: 10/18/2013] [Indexed: 01/01/2023] Open
Abstract
INTRODUCTION It remains unclear whether the clinical outcomes of patients with acute myocardial infarction (AMI) receiving second- and first-generation drug-eluting stents (DES) are identical. The study aimed to investigate the differences in clinical utility between the two generations of DES in these specific subjects by a meta-analysis. MATERIAL AND METHODS We systemically searched PubMed and EMBASE databases and the Cochrane Library up until January 2013. Randomized trials, which compared clinical outcomes of second-generation DES (everolimus- (EES) or zotarolimus-eluting stents (ZES)) with first-generation DES (sirolimus- or paclitaxel-eluting stents) in patients with AMI were included. RESULTS Five trials with 1720 AMI subjects were included in the meta-analysis. Pooled analysis demonstrated a trend toward lower incidence of stent thrombosis with the second-generation DES relative to the first-generation one (risk ratio (RR), 0.53; 95% confidence intervals (CI): 0.25-1.13; p = 0.10). However, the second-generation DES did not offer a significant advantage over the first-generation DES in reducing the incidence of target lesion revascularization (TLR) (RR = 1.73; 95% CI: 0.83-3.64; p = 0.15), major adverse cardiac events (MACEs) (RR = 0.97; p = 0.90), or all-cause death (RR = 1.00; p = 1.0). In addition, in elderly patients the second-generation DES seemed to reduce the occurrence of MACEs (RR = 0.65; p = 0.10) and stent thrombosis (RR = 0.40; p = 0.08), and the second-generation EES showed a potential benefit in lowering the MACE rate (RR = 0.55; p = 0.06). CONCLUSIONS The second-generation DES appeared to lower the risk of stent thrombosis in AMI patients. There might be a lower incidence of MACEs associated with the second-generation EES.
Collapse
Affiliation(s)
- Guodong Wu
- Department of Cardiology, First Hospital of Jilin University, Changchun, China
| | - Guoqiang Sun
- Department of Cardiology, First Hospital of Jilin University, Changchun, China
| | - Ruihong Zhao
- Department of Endoscopy and Gastroenterology, First Hospital of Jilin University, Changchun, China
| | - Mingli Sun
- Emergency Department, First Hospital of Jilin University, Changchun, China
| |
Collapse
|
8
|
Yan P, Dong P, Li Z. Second- versus first-generation drug-eluting stents for diabetic patients: a meta-analysis. Arch Med Sci 2014; 10:213-21. [PMID: 24904652 PMCID: PMC4042041 DOI: 10.5114/aoms.2014.42571] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2013] [Revised: 07/18/2013] [Accepted: 09/08/2013] [Indexed: 01/23/2023] Open
Abstract
INTRODUCTION The issue of whether various drug-eluting stents (DES) provide similar benefit in diabetic patients with coronary artery disease remains unclear. The purpose of the study is to assess the clinical utility of the second-generation and first-generation DES in patients with diabetes mellitus by a meta-analysis. MATERIAL AND METHODS A systematic literature search of PubMed, EMBASE, and Cochrane databases was conducted. We included randomized trials involving head-to-head comparison of clinical outcomes of second- versus first-generation DES in patients with a diagnosis of diabetes with at least 6-month follow-up data. Summary statistics were calculated using random-effects models. RESULTS A total of 10 trials with 4503 patients were available for analysis. The pooled analyses showed that the second-generation everolimus-eluting stent (EES) significantly lowered all-cause mortality (risk ratio (RR) = 0.58, 95% CI: 0.37-0.90; p = 0.01) and the risk of stent thrombosis (RR = 0.46, 95% CI: 0.22-0.95; p = 0.03) compared with the first-generation sirolimus-eluting stents (SES) and the overall first-generation DES, respectively. Moreover, the EES showed a tendency toward reducing the incidence of recurrent myocardial infarction when compared with paclitaxel-eluting stents (PES) (RR = 0.58, p = 0.08). In contrast, the second-generation zotarolimus-eluting stents (ZES) were associated with increased rates of stent thrombosis and risk of target lesion revascularization in comparison with the SES (both p < 0.05) or the overall first-generation DES (both p < 0.05). CONCLUSIONS The second-generation EES are highly effective in reducing the risk of major cardiac events in diabetic patients with coronary artery disease.
Collapse
Affiliation(s)
- Peng Yan
- Department of Cardiology, First Affiliated Hospital of Henan Science and Technology University, Luoyang, China
| | - Pingshuan Dong
- Department of Cardiology, First Affiliated Hospital of Henan Science and Technology University, Luoyang, China
| | - Zhijuan Li
- Department of Cardiology, First Affiliated Hospital of Henan Science and Technology University, Luoyang, China
| |
Collapse
|
9
|
Kleinbongard P, Baars T, Möhlenkamp S, Kahlert P, Erbel R, Heusch G. Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris. Am J Physiol Heart Circ Physiol 2013; 305:H1222-9. [DOI: 10.1152/ajpheart.00358.2013] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Stent implantation into atherosclerotic coronary arteries releases particulate debris and soluble substances that contribute to impaired microvascular perfusion. Here we addressed the potential for microvascular obstruction in patients with stenotic native right coronary arteries (nRCA) compared with saphenous vein grafts on right coronary arteries (SVG-RCA). We enrolled symptomatic, male patients with stable angina pectoris and a flow-limiting stenosis in their nRCA or SVG-RCA ( n = 18/18). Plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Coronary aspirate was retrieved during stent implantation under protection with a distal occlusion/aspiration device and divided into particulate debris and plasma. The release of catecholamines, endothelin, serotonin, thromboxane B2, and tumor necrosis factor-α was measured. The response of rat mesenteric arteries with intact (+E) and denuded (−E) endothelium to aspirate plasma (without and with selective endothelin receptor blockade) was normalized to that by potassium chloride (KClmax = 100%). Plaque volume and composition were not different between nRCA and SVG-RCA. There was less particulate debris (65 ± 8 vs. 146 ± 23 mg; P < 0.05) and more endothelin release (5.8 ± 0.8 vs. 1.3 ± 0.7 pg/ml; P < 0.05) in nRCA than in SVG-RCA, whereas the release of the other mediators was not different. Aspirate from nRCA induced stronger vasoconstriction than that from SVG-RCA [nRCA, 78 ± 6% (+E)/84 ± 5% (−E); SVG-RCA, 59 ± 6% (+E)/68 ± 3% (−E); P < 0.05 nRCA vs. SVG-RCA], which was attenuated by a nonspecific endothelin and a specific endothelin receptor A antagonist. Thus coronary aspirate from stented nRCA is characterized by less debris but more endothelin and stronger vasoconstrictor response than that from SVG-RCA.
Collapse
Affiliation(s)
- Petra Kleinbongard
- Institut für Pathophysiologie, Universitätsklinikum Essen, Essen, Germany
| | - Theodor Baars
- Klinik für Kardiologie, Universitätsklinikum Essen, Essen, Germany; and
| | | | - Philipp Kahlert
- Klinik für Kardiologie, Universitätsklinikum Essen, Essen, Germany; and
| | - Raimund Erbel
- Klinik für Kardiologie, Universitätsklinikum Essen, Essen, Germany; and
| | - Gerd Heusch
- Institut für Pathophysiologie, Universitätsklinikum Essen, Essen, Germany
| |
Collapse
|
10
|
Baars T, Konorza T, Kahlert P, Möhlenkamp S, Erbel R, Heusch G, Kleinbongard P. Coronary aspirate TNFα reflects saphenous vein bypass graft restenosis risk in diabetic patients. Cardiovasc Diabetol 2013; 12:12. [PMID: 23305356 PMCID: PMC3560373 DOI: 10.1186/1475-2840-12-12] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2012] [Accepted: 01/08/2013] [Indexed: 01/24/2023] Open
Abstract
BACKGROUND Patients with diabetes mellitus (DM) have an increased risk for periprocedural complications and adverse cardiac events after percutaneous coronary intervention. We addressed the potential for coronary microvascular obstruction and restenosis in patients with and without DM undergoing stenting for saphenous vein bypass graft (SVG) stenosis under protection with a distal occlusion/aspiration device. METHODS SVG plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Percent diameter stenosis was determined from quantitative coronary angiography before, immediately after and 6 months after stent implantation. Coronary aspirate was retrieved during stent implantation and divided into particulate debris and plasma. Total calcium, several vasoconstrictors, and tumor necrosis factor (TNF)α in particulate debris and coronary aspirate plasma were determined. RESULTS Patients with and without DM had similar plaque volume, but larger necrotic core and greater particulate debris release in patients with than without DM (20.3±2.7 vs. 12.7±2.6% and 143.9±19.3 vs. 75.1±10.4 mg, P<0.05). The TNFα concentration in particulate debris and coronary aspirate plasma was higher in patients with than without DM (15.9±6.6 vs. 5.1±2.4 pmol/mg and 2.2±0.7 vs. 1.1±0.2 pmol/L, P<0.05), whereas total calcium and vasoconstrictors were not different. Patients with DM had a greater percent diameter stenosis 6 months after stent implantation than those without DM (22.17±5.22 vs. 6.34±1.11%, P<0.05). The increase in TNFα immediately after stent implantation correlated with restenosis 6 months later (r=0.69, P<0.05). CONCLUSION In diabetics, particulate debris and coronary aspirate plasma contained more TNFα, which might reflect the activity of the underlying atherosclerotic process. TRIAL REGISTRATION URL: http://www.clinicaltrials.gov/ct2/results?term=NCT01430884; unique identifier: NCT01430884.
Collapse
Affiliation(s)
- Theodor Baars
- Institut für Pathophysiologie, Universitätsklinikum Essen, Hufelandstr 55, 45122 Essen, Germany
| | | | | | | | | | | | | |
Collapse
|
11
|
Baars T, Kleinbongard P, Böse D, Konorza T, Möhlenkamp S, Hippler J, Erbel R, Heusch G. Saphenous vein aorto-coronary graft atherosclerosis in patients with chronic kidney disease: more plaque calcification and necrosis, but less vasoconstrictor potential. Basic Res Cardiol 2012; 107:303. [PMID: 23052640 DOI: 10.1007/s00395-012-0303-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2012] [Revised: 09/20/2012] [Accepted: 09/24/2012] [Indexed: 12/12/2022]
Abstract
Atherosclerotic coronary arteries are more calcified in patients with than without chronic kidney disease (CKD). We addressed the potential for coronary microvascular obstruction in patients with and without CKD during stenting for saphenous vein aorto-coronary graft (SVG) stenosis under protection with a distal occlusion/aspiration device. In patients with and without CKD (n = 20/20), SVG plaque composition was analyzed from virtual histology using intravascular ultrasound analysis before stent implantation. There was more dense calcium and more necrotic core in patients with than without CKD (14 ± 3 vs. 3 ± 1 % and 21 ± 3 vs. 12 ± 2 % of plaque volume, respectively). Coronary aspirate was retrieved during stent implantation and divided into particulate debris and plasma. Patients with CKD had more particulate debris and calcium release than patients without CKD. In contrast, the release of serotonin was less in patients with than without CKD (0.4 ± 0.1 vs. 1.2 ± 0.3 μmol/L), whereas that of catecholamines, endothelin, tissue factor, thromboxane, tumor necrosis factor α, and C reactive protein was not significantly different. Confirming the biochemical results, aspirate plasma from patients with CKD induced less vasoconstriction of rat mesenteric arteries than that from patients without CKD (with endothelium (+E), 26 ± 7 %; without endothelium (-E): 28 ± 7 % vs. +E, 68 ± 12 %; -E: 95 ± 16 % of maximum KCl-induced vasoconstriction). Graft atherosclerosis of patients with CKD is more degenerated and releases more particulate debris and calcium, but the aspirate has surprisingly less serotonin and vasoconstrictor potential.
Collapse
Affiliation(s)
- Theodor Baars
- Institut für Pathophysiologie Universitätsklinikum Essen, Universität Duisburg-Essen, Germany
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Kleinbongard P, Baars T, Heusch G. Calcium antagonists in myocardial ischemia/reperfusion—update 2012. Wien Med Wochenschr 2012; 162:302-10. [DOI: 10.1007/s10354-012-0113-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2012] [Accepted: 04/03/2012] [Indexed: 01/10/2023]
|
13
|
Heusch G, Kleinbongard P, Skyschally A, Levkau B, Schulz R, Erbel R. The coronary circulation in cardioprotection: more than just one confounder. Cardiovasc Res 2012; 94:237-245. [DOI: 10.1093/cvr/cvr271] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
|
14
|
Schwartz BG, Kloner RA. Coronary no reflow. J Mol Cell Cardiol 2012; 52:873-82. [DOI: 10.1016/j.yjmcc.2011.06.009] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2011] [Revised: 06/10/2011] [Accepted: 06/13/2011] [Indexed: 10/18/2022]
|
15
|
Kleinbongard P, Konorza T, Böse D, Baars T, Haude M, Erbel R, Heusch G. Lessons from human coronary aspirate. J Mol Cell Cardiol 2011; 52:890-6. [PMID: 21762698 DOI: 10.1016/j.yjmcc.2011.06.022] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Revised: 06/24/2011] [Accepted: 06/28/2011] [Indexed: 10/18/2022]
Abstract
The interventional implantation of a stent into an atherosclerotic coronary artery is a unique and paradigmatic scenario of plaque rupture in humans. The use of protection devices not only prevents the released plaque particles and the superimposed thrombotic material from being washed and embolized into the coronary microcirculation of the individual patient, but permits also the retrieval and ex vivo analysis of particulate plaque debris and soluble substances. The particulate debris comprises typical cholesterol crystals, foam cells, hyalin material and calcium deposits from the atheroma as well as platelets and coagulation material; soluble substances include vasoconstrictors, such as serotonin and thromboxane, as well as inflammatory mediators, such as TNFα which amplifies vasoconstriction by inducing endothelial dysfunction. The vasoconstriction observed in a bioassay ex vivo correlates to clinical symptoms, angiographic stenosis and plaque burden, as assessed by intravascular ultrasound. The release of TNFα into the aspirate correlates to restenosis. Detailed analysis of the human coronary aspirate may promote a better understanding of the pathophysiology of the vulnerable atherosclerotic plaque and help to better antagonize the microvascular consequences of coronary microembolization, including the no reflow phenomenon. This article is part of a Special Issue entitled "Coronary Blood Flow."
Collapse
|