1
|
Moreau PE, Bokhari A, El Yahiouni S, Manach Q, Upex P, Riouallon G. Pubic symphysis tethering technique under endoscopic approach for treatment of pelvic open-book injury: A cadaver study. Trauma Case Rep 2024; 54:101107. [PMID: 39318770 PMCID: PMC11417513 DOI: 10.1016/j.tcr.2024.101107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/12/2024] [Indexed: 09/26/2024] Open
Abstract
Purpose Pubic symphysis disruption is common in pelvic trauma. Open reduction and internal fixation with a plate is the gold standard technique. Despite increasing interest in an endoscopic approach, the challenges of specific endoscopic instrumentation, reduction and fixation remains. In this feasibility cadaveric study, we aimed to describe a novel endoscopic technique of fixation of pubic symphysis disruption with a spinal vertebral tethering system. Methods Endoscopic pubic symphysis fixation with the tethering method was performed on a female cadaver specimen as well as an artificial pelvic model. Results We describe a step-by-step technique where three abdominal portals were utilized in order to insert screws in the pubic body and superior pubic ramus under endoscopic visualization. The synthetic tether ligament was introduced through a lateral portal and fixed and tensioned to reduce and compress the pubic symphysis. Conclusions While open plate fixation is the current gold standard of pubic symphysis disruption there is increasing interest in the minimally invasive endoscopic approach. In this feasibility cadaveric study, we present a new minimally invasive endoscopic fixation method to treat pubic symphysis disruption with a synthetic ligament.
Collapse
Affiliation(s)
- Pierre Emmanuel Moreau
- Orthopedic Department, Paris Saint-Joseph Hospital, 185, rue Raymond Losserand, 75014 Paris, France
| | - Ali Bokhari
- Orthopedic Department, Paris Saint-Joseph Hospital, 185, rue Raymond Losserand, 75014 Paris, France
| | - Sarah El Yahiouni
- Orthopedic Department, Paris Saint-Joseph Hospital, 185, rue Raymond Losserand, 75014 Paris, France
| | - Quentin Manach
- Orthopedic Department, Paris Saint-Joseph Hospital, 185, rue Raymond Losserand, 75014 Paris, France
| | - Peter Upex
- Orthopedic Department, Paris Saint-Joseph Hospital, 185, rue Raymond Losserand, 75014 Paris, France
| | - Guillaume Riouallon
- Orthopedic Department, Paris Saint-Joseph Hospital, 185, rue Raymond Losserand, 75014 Paris, France
| |
Collapse
|
2
|
Notov D, Knorr E, Spiegl UJA, Osterhoff G, Höch A, Kleber C, Pieroh P. The clinical relevance of fixation failure after pubic symphysis plating for anterior pelvic ring injuries: an observational cohort study with long-term follow-up. Patient Saf Surg 2024; 18:17. [PMID: 38778372 PMCID: PMC11112942 DOI: 10.1186/s13037-024-00401-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 05/09/2024] [Indexed: 05/25/2024] Open
Abstract
BACKGROUND Open reduction and plate fixation is a standard procedure for treating traumatic symphyseal disruptions, but has a high incidence of implant failure. Several studies have attempted to identify predictors for implant failure and discussed its impact on functional outcome presenting conflicting results. Therefore, this study aimed to identify predictors of implant failure and to investigate the impact of implant failure on pain and functional outcome. METHODS In a single-center, retrospective, observational non-controlled cohort study in a level-1 trauma center from January 1, 2006, to December 31, 2017, 42 patients with a plate fixation of a traumatic symphyseal disruption aged ≥ 18 years with a minimum follow-up of 12 months were included. The following parameters were examined in terms of effect on occurrence of implant failure: age, body mass index (BMI), injury severity score (ISS), polytrauma, time to definitive treatment, postoperative weight-bearing, the occurrence of a surgical site infection, fracture severity, type of posterior injury, anterior and posterior fixation. A total of 25/42 patients consented to attend the follow- up examination, where pain was assessed using the Numerical Rating Scale and functional outcome using the Majeed Pelvic Score. RESULTS Sixteen patients had an anterior implant failure (16/42; 37%). None of the parameters studied were predictive for implant failure. The median follow-up time was six years and 8/25 patients had implant failure. There was no difference in the Numerical Rating Scale, but the work-adjusted Majeed Pelvic Score showed a better outcome for patients with implant failure. CONCLUSION implant failure after symphyseal disruptions is not predictable, but appears to be clinically irrelevant. Therefore, an additional sacroiliac screw to prevent implant failure should be critically discussed and plate removal should be avoided in asymptomatic patients.
Collapse
Affiliation(s)
- Dmitry Notov
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany.
| | - Eva Knorr
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Ulrich J A Spiegl
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
- Clinic for Trauma Surgery and Orthopaedics, Munich Harlaching, Sanatoriumspl. 2, 81545, München, Germany
| | - Georg Osterhoff
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Andreas Höch
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Christian Kleber
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Philipp Pieroh
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| |
Collapse
|
3
|
Lotfalla A, Halm JA, Schepers T, Giannakópoulos GF. Parameters influencing health-related quality of life after severe trauma: a systematic review (part II). Eur J Trauma Emerg Surg 2024; 50:93-106. [PMID: 37188975 PMCID: PMC10923745 DOI: 10.1007/s00068-023-02276-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 05/02/2023] [Indexed: 05/17/2023]
Abstract
INTRODUCTION It is increasingly recognized that health-related quality of life (HRQoL) is a relevant outcome to study in populations comprising severely injured patients. Although some studies have readily demonstrated a compromised HRQoL in those patients, evidence regarding factors that predict HRQoL is scarce. This hinders attempts to prepare patient-specific plans that may aid in revalidation and improved life satisfaction. In this review, we present identified predictors of HRQoL in patients that have suffered severe trauma. METHODS The search strategy included a database search until the 1st of January 2022 in the Cochrane Library, EMBASE, PubMed, and Web of Science, and reference checking. Studies were eligible for inclusion when (HR)QoL was studied in patients with major, multiple, or severe injury and/or polytrauma, as defined by authors by means of an Injury Severity Score (ISS) cut-off value. The results will be discussed in a narrative manner. RESULTS A total of 1583 articles were reviewed. Of those, 90 were included and used for analysis. In total, 23 possible predictors were identified. The following parameters predicted reduced HRQoL in severely injured patients and came forward in at least more than three studies: higher age, female gender, lower extremity injuries, higher rate of injury severity, lower achieved educational level, presence of (pre-existing) comorbidities and mental illness, longer duration of hospital stay, and high level of disability. CONCLUSION Age, gender, injured body region, and severity of injury were found to be good predictors of health-related quality of life in severely injured patients. A patient-centered approach, based on individual, demographic, and disease-specific predictors, is highly recommended.
Collapse
Affiliation(s)
- Annesimone Lotfalla
- Department of Trauma Surgery, Trauma Unit, Amsterdam University Medical Center, Location Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
| | - Jens Anthony Halm
- Department of Trauma Surgery, Trauma Unit, Amsterdam University Medical Center, Location Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Tim Schepers
- Department of Trauma Surgery, Trauma Unit, Amsterdam University Medical Center, Location Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | - Georgios Fredericus Giannakópoulos
- Department of Trauma Surgery, Trauma Unit, Amsterdam University Medical Center, Location Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| |
Collapse
|
4
|
Berk T, Zderic I, Varga P, Schwarzenberg P, Berk K, Grüneweller N, Pastor T, Halvachizadeh S, Richards G, Gueorguiev B, Pape HC. Substitutional semi-rigid osteosynthesis technique for treatment of unstable pubic symphysis injuries: a biomechanical study. Eur J Trauma Emerg Surg 2023; 49:2569-2578. [PMID: 37555991 PMCID: PMC10728235 DOI: 10.1007/s00068-023-02333-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 07/15/2023] [Indexed: 08/10/2023]
Abstract
BACKGROUND/PURPOSE The surgical fixation of a symphyseal diastasis in partially or fully unstable pelvic ring injuries is an important element when stabilizing the anterior pelvic ring. Currently, open reduction and internal fixation (ORIF) by means of plating represents the gold standard treatment. Advances in percutaneous fixation techniques have shown improvements in blood loss, surgery time, and scar length. Therefore, this approach should also be adopted for treatment of symphyseal injuries. The technique could be important since failure rates, following ORIF at the symphysis, remain unacceptably high. The aim of this biomechanical study was to assess a semi-rigid fixation technique for treatment of such anterior pelvic ring injuries versus current gold standards of plate osteosynthesis. METHODS An anterior pelvic ring injury type III APC according to the Young and Burgess classification was simulated in eighteen composite pelvises, assigned to three groups (n = 6) for fixation with either a single plate, two orthogonally positioned plates, or the semi-rigid technique using an endobutton suture implant. Biomechanical testing was performed in a simulated upright standing position under progressively increasing cyclic loading at 2 Hz until failure or over 150,000 cycles. Relative movements between the bone segments were captured by motion tracking. RESULTS Initial quasi-static and dynamic stiffness, as well as dynamic stiffness after 100,000 cycles, was not significantly different among the fixation techniques (p ≥ 0.054).). The outcome measures for total displacement after 20,000, 40,000, 60,000, 80,000, and 100,000 cycles were associated with significantly higher values for the suture technique versus double plating (p = 0.025), without further significant differences among the techniques (p ≥ 0.349). Number of cycles to failure and load at failure were highest for double plating (150,000 ± 0/100.0 ± 0.0 N), followed by single plating (132,282 ± 20,465/91.1 ± 10.2 N), and the suture technique (116,088 ± 12,169/83.0 ± 6.1 N), with significantly lower values in the latter compared to the former (p = 0.002) and no further significant differences among the techniques (p ≥ 0.329). CONCLUSION From a biomechanical perspective, the semi-rigid technique for fixation of unstable pubic symphysis injuries demonstrated promising results with moderate to inferior behaviour compared to standard plating techniques regarding stiffness, cycles to failure and load at failure. This knowledge could lay the foundation for realization of further studies with larger sample sizes, focusing on the stabilization of the anterior pelvic ring.
Collapse
Affiliation(s)
- Till Berk
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland.
- Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
| | - Ivan Zderic
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland
| | - Peter Varga
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland
| | | | - Karlyn Berk
- Harald-Tscherne Laboratory for Orthopedic and Trauma Research, University of Zurich, Sternwartstrasse 14, 8091, Zurich, Switzerland
| | - Niklas Grüneweller
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland
- Department of Trauma Surgery and Orthopedics, Protestant Hospital of Bethel Foundation, University Hospital OWL of Bielefeld University, Campus Bielefeld‑Bethel, Burgsteig 13, 33617, Bielefeld, Germany
| | - Tatjana Pastor
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland
- Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Freiburgstrasse 15, 3010, Bern, Switzerland
| | - Sascha Halvachizadeh
- Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland
- Harald-Tscherne Laboratory for Orthopedic and Trauma Research, University of Zurich, Sternwartstrasse 14, 8091, Zurich, Switzerland
| | - Geoff Richards
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland
| | - Boyko Gueorguiev
- AO Research Institute Davos, Clavadelerstrasse 8, 7270, Davos, Switzerland
| | - Hans-Christoph Pape
- Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland
- Harald-Tscherne Laboratory for Orthopedic and Trauma Research, University of Zurich, Sternwartstrasse 14, 8091, Zurich, Switzerland
| |
Collapse
|
5
|
Tseng KY, Lin KC, Yang SW. The radiographic outcome after plating for pubic symphysis diastasis: does it matter clinically? Arch Orthop Trauma Surg 2023; 143:1965-1972. [PMID: 35278092 PMCID: PMC10030392 DOI: 10.1007/s00402-022-04411-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 02/26/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Open reduction and internal fixation with plates is the most widespread surgery in traumatic pubic symphysis diastasis. However, implant failure or recurrent diastasis was commonly observed during follow-up. The aim of our study was to evaluate the radiologic findings and clinical outcomes. MATERIALS AND METHODS Sixty-five patients with traumatic pubic symphysis diastasis treated with plating between 2008 and 2019 were retrospectively reviewed. The exclusion criteria were a history of malignancy and age under 20 years. Radiographic outcomes were determined by radiograph findings, including pubic symphysis distance (PSD) and implant failure. Clinical outcomes were assessed according to the Majeed score at the final follow-up. RESULTS Twenty-eight patients were finally included. Nine patients (32%) experienced implant failure, including four (14%) with screw loosening and five (18%) with plate breakage. Only one patient underwent revision surgery. Postoperatively, a significant increase in PSD was observed at 3 months and 6 months. Postoperative PSD was not significantly different between patients with single plating and double plating, but it was significantly greater in the implant-failure group than in the non-failure group. The Majeed score was similar between patients with single plating and double plating or between the implant-failure group and the non-failure group. Body mass index, number of plates, age, and initial injured PSD were not significantly different between the implant-failure group and the non-failure group. Only a significant male predominance was observed in the implant-failure group. CONCLUSION A gradual increase in the symphysis distance and a high possibility of implant failure may be the distinguishing features of traumatic pubic symphysis diastasis fixation. The postoperative symphyseal distance achieved stability after 6 months, even after implant failure. Radiographic outcomes, such as increased symphysis distance, screw loosening, and plate breakage, did not affect clinical functional outcomes.
Collapse
Affiliation(s)
- Kuo-Yuan Tseng
- Department of Orthopedics, Kaohsiung Veterans General Hospital, 386 Ta-Chung 1st Road, Kaohsiung, 81346, Taiwan
| | - Kai-Cheng Lin
- Department of Orthopedics, Kaohsiung Veterans General Hospital, 386 Ta-Chung 1st Road, Kaohsiung, 81346, Taiwan
| | - Shan-Wei Yang
- Department of Orthopedics, Kaohsiung Veterans General Hospital, 386 Ta-Chung 1st Road, Kaohsiung, 81346, Taiwan.
| |
Collapse
|
6
|
Moussa IS, Sallam AM, Mahmoud AK, Elzaher EH, Nagy AM, Eid AS. Combined anterior and posterior ring fixation versus posterior ring fixation alone in the management of unstable Tile B and C pelvic ring injuries: A randomized controlled trial. Chin J Traumatol 2023; 26:48-59. [PMID: 35750597 PMCID: PMC9912183 DOI: 10.1016/j.cjtee.2022.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 03/01/2022] [Accepted: 04/30/2022] [Indexed: 02/04/2023] Open
Abstract
PURPOSE Combined anterior and posterior ring (APR) fixation is classically performed in Tile B2 and C1 injuries to achieve superior biomechanical stability. However, the posterior ring (PR) is the main weight bearing portion that is responsible for weight transmission from the upper parts of the body to the lower limbs through the sacrum and the linea terminalis. It is hypothesized that isolated PR fixation can achieve comparable radiological and clinical outcomes to APR fixation. Therefore, we conducted this study to compare the two fixation principles in managing Tile B2 and C1 injuries. METHODS Our study included 20 patients with Tile B2 injuries and 20 patients with Tile C1 injuries. This study was a randomized control single-blinded study via computerized random numbers with a 1:1 allocation by using random block method. The study was performed at a level one trauma center. A total of 40 patients with Tile B2 and C1 injuries underwent combined APR or isolated PR fixation (Group A and B, respectively). Matta & Tornetta radiological principles and Majeed pelvic scoring system were used for the assessment of primary outcomes and postoperative complications. Secondary outcomes included operative time, amount of blood loss, intraoperative assessment of reduction, need of another operation, length of hospital stay, ability to weight bear postoperatively and pain control metrics. We used student t-test to compare the difference in means between two groups, and Chi-square test to compare proportions between two qualitative parameters. We set the confidence interval to 95% and the margin of error accepted to 5%. So, p ≤ 0.05 was considered statistically significant. RESULTS The mean follow-up duration was 18 months. The operative time (mean difference 0.575 h) and the intraoperative blood loss (mean difference 97.5 mL) were lower in Group B. Also, despite the higher frequency of rami displacement before union in the same group, there were no significant differences in terms of radiological outcome (excellent outcome with OR = 2.357), clinical outcome (excellent outcome with OR = 2.852) and postoperative complications assessment (OR = 1.556) at last follow-up. CONCLUSION The authors concluded that isolated PR fixation could favorably manage Tile B2 and C1 pelvic ring injuries with Nakatani zone II pubic rami fractures and intact inguinal ligament. Its final radiological and clinical outcomes and postoperative complications were comparable to combined APR fixation, but with less morbidity (shorter operation time, lower amount of blood, and no records of postoperative wound infection).
Collapse
Affiliation(s)
- Islam Sayed Moussa
- Department of Orthopedics and Traumatology, Faculty of Medicine, Ain Shams University, Cairo, 11522, Egypt.
| | | | | | | | | | | |
Collapse
|
7
|
Lotfalla A, Halm J, Schepers T, Giannakópoulos G. Health-related quality of life after severe trauma and available PROMS: an updated review (part I). Eur J Trauma Emerg Surg 2022; 49:747-761. [PMID: 36445397 PMCID: PMC10175342 DOI: 10.1007/s00068-022-02178-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Accepted: 11/11/2022] [Indexed: 11/30/2022]
Abstract
Abstract
Introduction
Throughout the years, a decreasing trend in mortality rate has been demonstrated in patients suffering severe trauma. This increases the relevance of documentation of other outcomes for this population, including patient-reported outcome measures (PROMs), such as health-related quality of life (HRQoL). The aim of this review was to summarize the results of the studies that have been conducted regarding HRQoL in severely injured patients (as defined by the articles’ authors). Also, we present the instruments that are used most frequently to assess HRQoL in patients suffering severe trauma.
Methods
A literature search was conducted in the Cochrane Library, EMBASE, PubMed, and Web of Science for articles published from inception until the 1st of January 2022. Reference lists of included articles were reviewed as well. Studies were considered eligible when a population of patients with major, multiple or severe injury and/or polytrauma was included, well-defined by means of an ISS-threshold, and the outcome of interest was described in terms of (HR)QoL. A narrative design was chosen for this review.
Results
The search strategy identified 1583 articles, which were reduced to 113 after application of the eligibility criteria. In total, nineteen instruments were used to assess HRQoL. The SF-36 was used most frequently, followed by the EQ-5D and SF-12. HRQoL in patients with severe trauma was often compared to normative population norms or pre-injury status, and was found to be reduced in both cases, regardless of the tool used to assess this outcome. Some studies demonstrated higher scoring of the patients over time, suggesting improved HRQoL after considerable time after severe trauma.
Conclusion
HRQoL in severely injured patients is overall reduced, regardless of the instrument used to assess it. The instruments that were used most frequently to assess HRQoL were the SF-36 and EQ-5D. Future research is needed to shed light on the consequences of the reduced HRQoL in this population. We recommend routine assessment and documentation of HRQoL in severely injured patients.
Collapse
|
8
|
Tape suture constructs for instabilities of the pubic symphysis: is the idea of motion preservation a suitable treatment option? A cadaver study. Arch Orthop Trauma Surg 2022; 143:3111-3117. [PMID: 35831608 DOI: 10.1007/s00402-022-04547-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 07/03/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION Current gold standard for the treatment of symphyseal disruptions includes anterior plating, almost entirely prohibiting symphyseal mobility and resulting in an iatrogenic arthrodesis followed by high rates of implant failure. Minimally invasive tape suture constructs have been found to maintain the micro mobility of ligamentous injuries, yet still providing sufficient biomechanical stability. Recently, this technique has been primarily investigated for symphyseal disruptions on synthetic pelvic models. Therefore, the aim of this study was to examine the feasibility of this novel flexible osteosynthesis on cadaveric pelvic models based on the following hypothesis: tape suture constructs ensure sufficient biomechanical stability without inhibiting micro mobility of the pubic symphysis for the treatment of symphyseal disruptions and maintain stability during long-term loading. MATERIALS AND METHODS 9 cadaveric anterior pelvic rings were used in this study and a symphyseal disruption was created in every specimen. The specimens were then exposed to short- and long-term vertical and horizontal cyclic loading after treatment with a tape suture construct in criss-cross technique. The mean maximum displacement (mm) during cyclic loading and the corresponding stiffness (N/mm) were measured and compared. RESULTS Regarding both displacement (mm) and corresponding stiffness (N/mm), the tape sutures displayed a significant difference between short- and long-term loading for cranial and caudal vertical loading (p < 0.01) but differences remained non-significant for horizontal loading (p > 0.05). No tape suture suffered from implant failure during long-term loading. CONCLUSIONS The tape suture construct displayed sufficient biomechanical stability without exceeding the physiological mobility of 2 mm of the pubic symphysis; however, also maintained the desired micro mobility of the affected joint necessary to prevent an iatrogenic arthrodesis. Further, all tape sutures maintained stability throughout long-term loading.
Collapse
|
9
|
Hinz N, Dehoust J, Schroeter J, Schulz AP, Hartel MJ, Lutz C, Frosch KH, Wendlandt R. Biomechanical in vitro analysis of a novel flexible implant for pubic symphysis disruption using an ultra-high molecular weight polyethylene fiber cord. Clin Biomech (Bristol, Avon) 2022; 95:105652. [PMID: 35489167 DOI: 10.1016/j.clinbiomech.2022.105652] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 04/12/2022] [Accepted: 04/19/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Plate osteosynthesis depicts the gold standard to surgically treat pubic symphysis disruptions. However, high rates of implant failure after plate osteosynthesis are reported, probably because of the iatrogenic arthrodesis of this fibrocartilaginous joint. Therefore, flexible implants for treatment of pubic symphysis disruptions appear to be a sensible solution. METHODS In this biomechanical screening study, we designed and investigated a flexible implant, which consists of two plates connected with an ultra-high molecular weight polyethylene fiber cord. We mechanically tested eye splices as a possible fixation method of the cords by performing tensile load to failure tests. Afterwards, we developed a biomechanically appropriate plate design and cord routing between the plates. Finally, we biomechanically tested the flexible implant under tensile and shear loading until failure. FINDINGS When fixing a 1 mm ultra-high molecular weight polyethylene fiber cord with eye splices, a load at failure of 1570.74 N was detected under tensile loading. None of the eye splices failed but the cords itself ruptured. The load at failure of the designed cord routing in criss-cross technique and fixation within the plates amounts 4742.09 N under tensile and 2699.77 N under shear load. INTERPRETATION We developed a novel flexible implant for repair of pubic symphysis disruptions using ultra-high molecular weight polyethylene fiber cords connected to osteosynthesis plates. We identified eye splices as a mechanically optimal fixation method and proved that the ultra-high molecular weight polyethylene fiber cord routing and fixation of the flexible implant clearly withstands physiological forces acting on the pubic symphysis.
Collapse
Affiliation(s)
- Nico Hinz
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Trauma Hospital Hamburg, Bergedorfer Strasse 10, 21033 Hamburg, Germany.
| | - Julius Dehoust
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Trauma Hospital Hamburg, Bergedorfer Strasse 10, 21033 Hamburg, Germany.
| | - Jörg Schroeter
- Laboratory for Biomechanics, Department of Orthopedics and Trauma Surgery, University Lübeck, Ratzeburger Allee 160, 23538 Lübeck, Germany.
| | - Arndt-Peter Schulz
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Trauma Hospital Hamburg, Bergedorfer Strasse 10, 21033 Hamburg, Germany; Fraunhofer Research Institution for Individualized and Cell-Based Medical Engineering, Mönkhofer Weg 239 a, 23562 Lübeck, Germany.
| | - Maximilian J Hartel
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Trauma Hospital Hamburg, Bergedorfer Strasse 10, 21033 Hamburg, Germany; Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany.
| | | | - Karl-Heinz Frosch
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Trauma Hospital Hamburg, Bergedorfer Strasse 10, 21033 Hamburg, Germany; Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany.
| | - Robert Wendlandt
- Laboratory for Biomechanics, Department of Orthopedics and Trauma Surgery, University Lübeck, Ratzeburger Allee 160, 23538 Lübeck, Germany.
| |
Collapse
|
10
|
Shon HC, Kang HW, Lim EJ, Yang JY. Delayed bladder perforation due to screw loosening after pelvic ring injury surgery: a case report. JOURNAL OF TRAUMA AND INJURY 2022; 35:51-55. [PMID: 39381526 PMCID: PMC11309364 DOI: 10.20408/jti.2021.0054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 09/22/2021] [Accepted: 09/24/2021] [Indexed: 11/05/2022] Open
Abstract
Pelvic ring injuries have high mortality and morbidity rates, and they are difficult to treat because accompanying injuries to the pelvic organs, genitourinary organs, and neurovascular tissues are common. Genitourinary injuries are common comorbid injuries that have been reported to occur in 5% to 6% of all pelvic ring injuries. However, these injuries usually occur simultaneously with the pelvic ring injury, whereas relatively little research has dealt with genitourinary injuries that occur after treatment of a pelvic ring injury. To the best of our knowledge, only three cases of delayed bladder perforation due to screw loosening after symphyseal plate fixation in anterior pelvic ring injury have been reported worldwide, and no such cases have yet been reported in Korea. Since the authors experienced this very rare complication after pelvic ring surgery, we report this case along with a literature review.
Collapse
Affiliation(s)
- Hyun-Chul Shon
- Department of Orthopaedic Surgery, Chungbuk National University Hospital, Cheongju, Korea
| | - Ho-Won Kang
- Department of Urology, Chungbuk National University Hospital, Cheongju, Korea
| | - Eic-Ju Lim
- Department of Orthopaedic Surgery, Chungbuk National University Hospital, Cheongju, Korea
| | - Jae-Young Yang
- Department of Orthopaedic Surgery, Chungbuk National University Hospital, Cheongju, Korea
| |
Collapse
|
11
|
Hörlesberger N, Hohenberger G, Grechenig P, Schwarz A, Grechenig C, Ornig M, Tackner E, Gänsslen A. Danger zone - The spermatic cord during anterior plating of the symphysis pubis. Injury 2022; 53:519-522. [PMID: 34620470 DOI: 10.1016/j.injury.2021.09.045] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 09/08/2021] [Accepted: 09/26/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Distances between anatomic landmarks and anatomic structures at risk are often underestimated by surgeons. PURPOSE The goal of the study was to evaluate the distances between anatomic landmarks and the spermatic cord in case of anterior plating of the symphysis. METHODS A total of 25 pelves (50 hemipelves) of male embalmed cadavers were dissected. A 5-hole 3.5mm locking compression plate (Synthes GmbH) was fixed from directly anterior on the symphysis. Measurements were taken 1) distance between the tips of both pubic tubercles, 2) horizontal interval between the lateral border of the plate and the medial margin of the SC (bilateral), 3) distances between the medial border of the SC and the tip of the pubic tubercle (bilateral), 4) distances between the medial border of the SC and the lateral basis of the pubic tubercle (bilateral). RESULTS The distance between the pubic tubercles was 60.3mm in average (SD: 5.7). The interval between the lateral border of the plate and the medial margin of the SC was on average 4.5mm (SD: 1.9) on the right and 4.7mm (SD: 2.6) on the left side. The distance between the tip of the pubic tubercle and the medial border of the SC was in average 11.2mm (SD: 2.7) on the right, and 11.0mm (SD: 2.7) on the left side. The average distance between the medial border of the SC and the lateral basis of the pubic tubercle was 8.1mm (SD: 2.4) on the right and 8.2 mm (SD: 2.4) on the left side. CONCLUSION The SC is at risk not only during dissection but also during anterior plating of the symphysis, because of its close relation to the SC. CLINICAL RELEVANCE Average distances between the palpable pubic tubercle and the SC are below one finger breadth (as reference).
Collapse
Affiliation(s)
- Nina Hörlesberger
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
| | - Gloria Hohenberger
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria; Department of Trauma Surgery, State Hospital Feldbach-Fürstenfeld. Address: Ottokar-Kernstock-Straße 18, 8330 Feldbach, Austria.
| | - Peter Grechenig
- Department of Orthopedics and Trauma, Paracelsus Medical University. Address: Müllner Hauptstraße 48, 5020 Salzburg, Austria
| | - Angelika Schwarz
- AUVA Trauma Hospital Styria, Graz. Address: Göstinger Str. 24, 8020 Graz, Austria
| | - Christoph Grechenig
- Department of Ophthalmology, Medical University of Vienna. Address: Währinger Gürtel 18-20, 1090 Vienna, Austria
| | - Martin Ornig
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
| | - Ellen Tackner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria.
| | - Axel Gänsslen
- Clinic for Trauma Surgery, Orthopedics and Hand Surgery, Klinikum Wolfsburg. Address: Sauerbruchstraße 7, 38440 Wolfsburg, Germany
| |
Collapse
|
12
|
Kabir K, Lingohr P, Jaenisch M, Hackenberg RK, Sommer N, Ossendorff R, Welle K, Gathen M. Total endoscopic anterior pelvic approach (TAPA) - A new approach to the internal fixation of the symphysis. Injury 2022; 53:802-808. [PMID: 34635336 DOI: 10.1016/j.injury.2021.09.043] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 09/25/2021] [Accepted: 09/25/2021] [Indexed: 02/02/2023]
Abstract
This study presents a detailed documentation of a total endoscopic anterior pelvic approach (TAPA) for plate fixation of a symphyseal disruption. The purpose of this work is to describe a minimally invasive technique as a possible method for reducing complications and hospitalization. Other goals included giving technical recommendations and assessing potential pitfalls and problems of this new surgical approach. Surgery was performed in an interdisciplinary setting by an experienced orthopaedic and general surgeon. The first endoscopic approach used to visualize the injury was the same as is used for endoscopic hernia surgery. The repositioning of the symphysial rupture was achieved either through external fixation or indirectly with traction and a pelvic binder. Plate positioning and fixation were achieved through two additional, minimally invasive incisions. The endoscopic approach shows multiple advantages, such as no detachment of the rectus abdominis muscle and smaller skin incisions. Furthermore, this approach could lessen the incidence of hernia and postoperative pain. We see the presented technique as a simple and innovative surgical method for treating symphyseal disruption.
Collapse
Affiliation(s)
- Koroush Kabir
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn, Germany
| | - Philipp Lingohr
- Department of General, Visceral, Thoracic and Vascular Surgery, University Hospital of Bonn, Bonn, Germany
| | - Max Jaenisch
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn, Germany
| | | | - Nils Sommer
- Department of General, Visceral, Thoracic and Vascular Surgery, University Hospital of Bonn, Bonn, Germany
| | - Robert Ossendorff
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn, Germany
| | - Kristian Welle
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn, Germany
| | - Martin Gathen
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn, Germany.
| |
Collapse
|
13
|
Cavalcanti Kußmaul A, Schwaabe F, Kistler M, Gennen C, Andreß S, Becker CA, Böcker W, Greiner A. Novel minimally invasive tape suture osteosynthesis for instabilities of the pubic symphysis: a biomechanical study. Arch Orthop Trauma Surg 2022; 142:2235-2243. [PMID: 34052913 PMCID: PMC9381629 DOI: 10.1007/s00402-021-03968-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 05/18/2021] [Indexed: 01/13/2023]
Abstract
INTRODUCTION Open book fractures are challenging injuries oftentimes requiring surgical treatment. The current treatment of choice is symphyseal plating, which requires extensive surgery and entirely limits physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a semi-rigid implant (modified SpeedBridge™) as a minimally invasive tape suture construct for the treatment of open book fractures and evaluated the superiority of two techniques of implementation: criss-cross vs. triangle technique. MATERIALS AND METHODS Nine synthetic symphyseal joints were dissected creating an open book fracture. The different osteosynthesis methods (plating, modified SpeedBridge™ in criss-cross/triangle technique) were then applied. All constructs underwent horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, dislocation (mm) and stiffness (N/mm) were calculated. RESULTS Symphyseal plating for the treatment of open book fractures proved to be a rigid osteosynthesis significantly limiting the physiological mobility of the symphyseal joint (dislocation: 0.08 ± 0.01 mm) compared to the tape sutures (dislocation: triangle technique 0.27 ± 0.07 mm, criss-cross technique 0.23 ± 0.05 mm) regarding horizontal tension (p < 0.01). Both modified SpeedBridge™ techniques showed sufficient biomechanical stability without one being superior to the other (p > 0.05 in all directions). Considering vertical loading, no statistical difference was found between all osteosynthesis methods (caudal: p = 0.41; cranial: p = 0.61). CONCLUSIONS Symphyseal plating proved to be the osteosynthesis method with the highest rigidity. The modified SpeedBridge™ as a semi-rigid suture construct provided statistically sufficient biomechanical stability while maintaining a minimum of symphyseal movement, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis. Furthermore, both the criss-cross and the triangle technique displayed significant biomechanical stability without one method being superior.
Collapse
Affiliation(s)
- Adrian Cavalcanti Kußmaul
- grid.411095.80000 0004 0477 2585Department of General Trauma and Reconstructive Surgery, University Hospital LMU Munich, Munich, Germany
| | - Fanny Schwaabe
- grid.411095.80000 0004 0477 2585Department of General Trauma and Reconstructive Surgery, University Hospital LMU Munich, Munich, Germany
| | - Manuel Kistler
- grid.411095.80000 0004 0477 2585Department of Orthopedics, Physical Medicine and Rehabilitation, University Hospital LMU Munich, Munich, Germany
| | - Clara Gennen
- grid.411095.80000 0004 0477 2585Department of Obstetrics and Gynecology, University Hospital LMU Munich, Munich, Germany
| | - Sebastian Andreß
- grid.411095.80000 0004 0477 2585Department of General Trauma and Reconstructive Surgery, University Hospital LMU Munich, Munich, Germany
| | - Christopher A. Becker
- grid.411095.80000 0004 0477 2585Department of General Trauma and Reconstructive Surgery, University Hospital LMU Munich, Munich, Germany
| | - Wolfgang Böcker
- grid.411095.80000 0004 0477 2585Department of General Trauma and Reconstructive Surgery, University Hospital LMU Munich, Munich, Germany
| | - Axel Greiner
- grid.411095.80000 0004 0477 2585Department of General Trauma and Reconstructive Surgery, University Hospital LMU Munich, Munich, Germany
| |
Collapse
|
14
|
Rojas C, Ewertz E, Hormazábal JM. Fixation failure in patients with traumatic diastasis of pubic symphysis: impact of loss of reduction on early functional outcomes. J Orthop Surg Res 2021; 16:661. [PMID: 34742331 PMCID: PMC8572449 DOI: 10.1186/s13018-021-02802-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 10/18/2021] [Indexed: 11/24/2022] Open
Abstract
Background Failure of fixation (FF) in pubic symphysis diastasis (SD) ranges between 12 and 75%, though whether it influences functional outcomes is still debated. The objective of this study is to evaluate the impact of anterior pelvic plate failure and loss of reduction on Majeed’s functional scores.
Methods Single center retrospective review of consecutive patients with acute SD treated by means of anterior pubic plating. Thirty-seven patients with a mean age 45.7 ± 14.4 years were included. Demographics, AO classification, pelvic fixation and secondary procedures were recorded. Majeed’s functional scores at minimum 6 months follow-up were compared according to the presence of FF and loss of reduction. Results Fifteen patients presented FF. Eight presented an additional loss of symphyseal reduction. Mean Majeed´s score (MMS) in patients with and without FF was 64.4 ± 13.04 and 81.8 ± 15.65, respectively (p = 0.0012). Differences in MMS in patients without FF and those with FF and maintained or loss of anterior reduction were 11.3 [70.5 vs 81.8] (p = 0.092) and 22.7 [59.1 vs 81.8] (p = 0.001), respectively. Significant association of FF with AO classification was noted. (OR 12.6; p = 0.002). Conclusions Differences in MMS in the analyzed groups suggest that loss of reduction might be more relevant than failure of the anterior osteosynthesis in functional outcomes.
Collapse
Affiliation(s)
- Claudio Rojas
- Department of Orthopaedic Surgery, Hospital del Trabajador de Santiago, Ramón Carnicer 185, 7501239, Santiago, Chile.,Department of Orthopaedic Surgery, Clínica Dávila, Recoleta 464, 8431657, Santiago, Chile
| | - Ernesto Ewertz
- Department of Orthopaedic Surgery, Clínica Dávila, Recoleta 464, 8431657, Santiago, Chile.
| | - Jose Miguel Hormazábal
- Department of Orthopaedic Surgery, Hospital del Trabajador de Santiago, Ramón Carnicer 185, 7501239, Santiago, Chile
| |
Collapse
|
15
|
Can locking plate fixation of symphyseal disruptions allow early weight bearing? Injury 2021; 52:2725-2729. [PMID: 32107009 DOI: 10.1016/j.injury.2020.02.094] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 02/05/2020] [Accepted: 02/17/2020] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Anterior pubic symphyseal plate fixation is the recommended treatment for disruption of pubic symphysis in an unstable pelvic ring injury. The rigid construct offered by locking symphyseal plate has the theoretical advantage of allowing patients to weight bear early. However, there are concerns of catastrophic failure about the locked plate construct. The purpose of the study was to establish if locking plate fixation for pubic symphysis disruption was effective to allow patients to mobilise weight bearing immediately after surgery. PATIENT AND METHODS Retrospective analysis of a prospectively collected database from a single centre was performed. The study period was from 2008 to 2017. Radiographic evidence of fixation failure, revision surgery, removal of metalwork and follow up duration was noted. RESULTS We identified 46 patients (F:M 8:38) with a mean age of 46 years (range 14 to 74 years). Based on the mechanism of injury patients were classified into Antero-posterior compression (28), Vertical shear [10], lateral compression [4] and combined mechanism [4]. Either a 4-hole or 6-hole locking plate was used in all patients, depending on fracture extension. Posterior fixation was required in 28 (61%) patients. All patients were allowed to fully or partial weight bear. The mean radiological follow-up period was 31 weeks with 13 (28%) patients having evidence of radiological failure. Revision was performed in 1 (2%) patient, in whom the screws had pulled out of the bone. The most common mode of failure was either the screw backing out from the plate or broken screw. Among the 4 (8%) patients who had their metalwork removed, 1 (2%) had delayed onset of infection, 2 (4%) had symptoms related to backed out screw and 1 (2%) opted electively to have metalwork removed. CONCLUSIONS With our series of patients, we have found that using locking plate for pubic symphyseal diastasis is safe and effective in allowing patients to weight bear early. A low complication rate and need for re-operation is demonstrated.
Collapse
|
16
|
Kabir K, Welle K, Lingohr P, Jaenisch M, Roos J, Gathen M. APACHE-Anterior Plating of the Acetabulum in Hemi-Endoscopic Technique: An Alternative Method for Internal Fixation of the Acetabulum. Arthrosc Tech 2021; 10:e1815-e1819. [PMID: 34336580 PMCID: PMC8322669 DOI: 10.1016/j.eats.2021.03.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 03/26/2021] [Indexed: 02/03/2023] Open
Abstract
Injuries of the acetabulum are often challenging in treatment and aftercare. One reason is the required surgical approach, which has high complication rates, including vascular lesion, hernias, and wound infection. We present an alternative endoscopic-assisted approach for the internal fixation of acetabular fractures to avoid the Pfannenstiel incision. An endoscopic approach similar to that used for endoscopic hernia surgery was used. The ilioinguinal approach's lateral window was used to achieve reduction and insertion of a reconstruction plate. The purpose of this study is to describe a minimally invasive technique as a possible method to reduce hospitalization and complications. Another goal is to give detailed technical recommendations and to assess the potential pitfalls of this surgical approach. The APACHE technique is a safe and suitable minimally-invasive approach for the successful treatment of complex acetabular fractures and can be considered in similar cases.
Collapse
Affiliation(s)
- Koroush Kabir
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn
| | - Kristian Welle
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn
| | - Philipp Lingohr
- Department of Surgery, University Hospital of Bonn, Bonn, Germany
| | - Max Jaenisch
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn
| | - Jonas Roos
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn
| | - Martin Gathen
- Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, Bonn,Address correspondence to Martin Gathen, M.D., University Hospital of Bonn, Dept. of Orthopedics and Trauma Surgery, Venusberg-Campus 1, 53127 Bonn, Germany.
| |
Collapse
|
17
|
Orthopedic injuries in patients with multiple injuries: Results of the 11th trauma update international consensus conference Milan, December 11, 2017. J Trauma Acute Care Surg 2020; 88:e53-e76. [PMID: 32150031 DOI: 10.1097/ta.0000000000002407] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND In blunt trauma, orthopedic injuries are often associated with cerebral and torso injuries. The optimal timing for definitive care is a concern. The aim of the study was to develop evidence-based guidelines for damage-control orthopedic (DCO) and early total care (ETC) of pelvic and long-bone fractures, closed or open, and mangled extremities in adult trauma patients with and without associated injuries. METHODS The literature since 2000 to 2016 was systematically screened according to Preferred Reporting Items for Systematic Reviews and meta-analyses protocol. One hundred twenty-four articles were reviewed by a panel of experts to assign grade of recommendation and level of evidence using the Grading of recommendations Assessment, Development, and Evaluation system, and an International Consensus Conference, endorsed by several scientific societies was held. RESULTS The choice between DCO and ETC depends on the patient's physiology, as well as associated injuries. In hemodynamically unstable pelvic fracture patient, extraperitoneal pelvic packing, angioembolization, external fixation, C-clamp, and resuscitative endovascular balloon occlusion of the aorta are not mutually exclusive. Definitive reconstruction should be deferred until recovery of physiological stability. In long bone fractures, DCO is performed by external fixation, while ETC should be preferred in fully resuscitated patients because of better outcomes. In open fractures early debridement within 24 hours should be recommended and early closure of most grade I, II, IIIa performed. In mangled extremities, limb salvage should be considered for non-life-threatening injuries, mostly of upper limb. CONCLUSION Orthopedic priorities may be: to save a life: control hemorrhage by stabilizing the pelvis and femur fractures; to save a limb: treat soft tissue and vascular injuries associated with fractures, stabilize fractures, recognize, and prevent compartmental syndrome; to save functionality: treat dislocations, articular fractures, distal fractures. While DCO is the best initial treatment to reduce surgical load, ETC should be applied in stable or stabilized patients to accelerate the recovery of normal functions. LEVEL OF EVIDENCE Systematic review of predominantly level II studies, level II.
Collapse
|
18
|
Rickman M, Link BC, Solomon LB. Patient Weight-bearing after Pelvic Fracture Surgery-A Systematic Review of the Literature: What is the Modern Evidence Base? Strategies Trauma Limb Reconstr 2019; 14:45-52. [PMID: 32559267 PMCID: PMC7001596 DOI: 10.5005/jp-journals-10080-1414] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Background Little attention in the literature appears to have been paid to the issue of postoperative weight-bearing protocols for different injury patterns after pelvic fracture surgery. The primary aim of this study is to review the currently available literature to define the level of available evidence used to inform surgical decisions on weight-bearing after pelvic fracture surgery. Secondary aims are to assess the published methods of fracture classification, surgical management, and assessment or reporting of patient outcomes. Methods A systematic review of the English language literature from 1990 to 2016 was undertaken. Eligible papers were all papers reporting minimum 6-month outcomes following surgery for pelvic fractures in adults. Exclusion criteria included pathological fractures or those resulting from penetrating injury, solely osteoporotic fractures, or series with less than 6 months of follow-up data. Results There is very little published scientific data to inform the treating surgeon on postoperative weight-bearing protocols after pelvic fracture surgery, with no randomized trials and only 1 paper out of 122 stating this as a primary aim. More than half of the papers published did not state what postoperative protocol was employed. There is no standardization of outcome measures, with less than 20% of papers using the most common validated outcome scoring system; in contrast, there is good agreement on the use of either the Tile (75%) or Burgess and Young (20%) classification. Limitations Due to the lack of published studies looking at the topic of postoperative weight-bearing after pelvic fractures, no specific recommendations are possible. As large numbers of papers were included, they were not individually assessed for bias. Conclusion A review of postoperative weight-bearing regimes reveals a nonexistent scientific evidence base from which to make recommendations, although a consensus strategy has been identified. Future research needs to be directed at this topic, as has already been the case in numerous other fracture areas, since the advantages of early mobility are potentially significant. The reported methodology for assessing and reporting patient outcomes after pelvic fracture surgery reveals no consistent standards, and the majority of papers use no specific outcome scoring system. How to cite this article Rickman M, Link B-C, Solomon LB. Patient Weight-bearing after Pelvic Fracture Surgery-A Systematic Review of the Literature: What is the Modern Evidence Base? Strategies Trauma Limb Reconstr 2019;14(1):45-52.
Collapse
Affiliation(s)
- Mark Rickman
- Centre for Orthopaedic and Trauma Research, Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Bjorn-Christian Link
- Centre for Orthopaedic and Trauma Research, Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Lucian B Solomon
- Centre for Orthopaedic and Trauma Research, Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| |
Collapse
|
19
|
Schmal H, Froberg L, S Larsen M, Südkamp NP, Pohlemann T, Aghayev E, Goodwin Burri K. Evaluation of strategies for the treatment of type B and C pelvic fractures: results from the German Pelvic Injury Register. Bone Joint J 2018; 100-B:973-983. [PMID: 29954203 DOI: 10.1302/0301-620x.100b7.bjj-2017-1377.r1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Aims The best method of treating unstable pelvic fractures that involve the obturator ring is still a matter for debate. This study compared three methods of treatment: nonoperative, isolated posterior fixation and combined anteroposterior stabilization. Patients and Methods The study used data from the German Pelvic Trauma Registry and compared patients undergoing conservative management (n = 2394), surgical treatment (n = 1345) and transpubic surgery, including posterior stabilization (n = 730) with isolated posterior osteosynthesis (n = 405) in non-complex Type B and C fractures that only involved the obturator ring anteriorly. Calculated odds ratios were adjusted for potential confounders. Outcome criteria were intraoperative and general short-term complications, the incidence of nerve injuries, and mortality. Results Operative stabilization reduced mortality by 36% (odds ratio (OR) 0.64, 95% confidence interval (CI) 0.42 to 0.98) but the incidence of complications was twice as high (OR 2.04, 95% CI 1.57 to 2.64). Mortality and the incidence of neurological deficits at discharge were no different after isolated posterior or combined anteroposterior fixation. However, the odds of both surgical (98%, OR 1.98, 95%CI 1.22 to 3.22) and general complications (43%, OR 1.43, 95% CI 1.02 to 2.00) were higher in the group with the more extensive surgery. Conclusion Operative stabilization is recommended for non-complex unstable pelvic fractures. The need for anterior fixation of obturator ring fractures should, however, be considered critically. Cite this article: Bone Joint J 2018;100-B:973-83.
Collapse
Affiliation(s)
- H Schmal
- Department of Orthopaedics and Traumatology, Odense University Hospital, and Department of Clinical Research, University of Southern Denmark, Odense, Denmark and Department of Orthopaedics and Trauma Surgery, Medical Center, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - L Froberg
- Department of Orthopaedics and Traumatology, Odense University Hospital and Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - M S Larsen
- Department of Orthopaedics and Traumatology, Odense University Hospital, Odense, Denmark and Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - N P Südkamp
- Department of Orthopaedics and Trauma Surgery, Medical Center, Albert-Ludwigs-University of Freiburg, Freiburg, Germany
| | - T Pohlemann
- Department of Trauma, Hand and Reconstructive Surgery, Saarland University Hospital, Homburg, Germany
| | - E Aghayev
- Spine Centre Division, Department of Research and Development, Schulthess Klinik, Zurich, Switzerland
| | - K Goodwin Burri
- Swiss Medical Registries and Data Linkage (SwissRDL), Institute of Social and Preventive Medicine (ISPM), University of Bern, Bern, Switzerland
| |
Collapse
|
20
|
Petryla G, Uvarovas V, Šatkauskas I, Masionis P, Porvaneckas N. Non-anatomic fixation for longstanding traumatic pubic diastasis using a bone graft: A report of two cases. Chin J Traumatol 2017; 20:362-365. [PMID: 29198716 PMCID: PMC5832458 DOI: 10.1016/j.cjtee.2017.06.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2017] [Revised: 07/03/2017] [Accepted: 07/14/2017] [Indexed: 02/04/2023] Open
Abstract
The incidence of internal fixation failure of symphysis diastasis varies from 6% to 75%. Hardware breakage or migration and symphysis disruption recurrence are often asymptomatic and only in a few cases reoperation is required. This report describes the managements of two cases after failed internal fixation and neglected traumatic symphysis diastasis when it was technically impossible to achieve anatomical reduction of the anterior pelvic ring. Internal fixation and a bone graft for the symphysis without anatomical reposition were performed. Both of the patients achieved good results and had no complaints of pain during daily activities. Restoration of the anatomy should not be the aim in treating recurrence of the symphysis diastasis after failed fixation. The aim of the surgery was static fixation of the anterior pelvic ring with bone grafting.
Collapse
Affiliation(s)
- Giedrius Petryla
- Department of Orthopedics and Traumatology, Vilnius University Faculty of Medicine, Republican Vilnius University Hospital, Šiltnamių Str. 29, 04130, Vilnius, Lithuania
| | - Valentinas Uvarovas
- Department of Orthopedics and Traumatology, Vilnius University Faculty of Medicine, Republican Vilnius University Hospital, Šiltnamių Str. 29, 04130, Vilnius, Lithuania
| | - Igoris Šatkauskas
- Department of Orthopedics and Traumatology, Vilnius University Faculty of Medicine, Republican Vilnius University Hospital, Šiltnamių Str. 29, 04130, Vilnius, Lithuania
| | - Povilas Masionis
- Department of Orthopedics and Traumatology, Vilnius University Faculty of Medicine, Republican Vilnius University Hospital, Šiltnamių Str. 29, 04130, Vilnius, Lithuania.
| | - Narūnas Porvaneckas
- Department of Orthopedics and Traumatology, Vilnius University Faculty of Medicine, Republican Vilnius University Hospital, Šiltnamių Str. 29, 04130, Vilnius, Lithuania
| |
Collapse
|
21
|
Gu R, Huang W, Yang L, Liu H, Xie K, Huang Z. Comparisons of front plate, percutaneous sacroiliac screws, and sacroiliac anterior papilionaceous plate in fixation of unstable pelvic fractures. Medicine (Baltimore) 2017; 96:e7775. [PMID: 28885332 PMCID: PMC6392970 DOI: 10.1097/md.0000000000007775] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND This observational study was aimed at comparing the clinical efficacy of sacroiliac anterior plate fixation (SAPF), sacroiliac anterior papilionaceous plate (SAPP), and percutaneous sacroiliac screw internal fixation (PSCIF) introduced for patients with unstable pelvic fracture. METHODS Seventy-eight patients with unstable pelvic fracture (Tile type B or C) were recruited. Twenty-six patients underwent SAPF, 26 underwent SAPP, and 26 underwent PSCIF. Matta scores were calculated to evaluate the reduction of pelvic fractures, and Majeed scores were applied for the assessment of functional recoveries after surgery. Other perioperative clinical indicators were also recorded, including operation time, bleeding status, length of incision, ambulation time, fracture healing time, and incision infection. RESULTS Total operation time of PSCIF was remarkably shorter than that of SAPF and SAPP (P < .05), and the bleeding volume of SAPF and SAPP group was almost 26∼29 times as high as that of PSCIF group (P < .05). Besides, SAPP resulted in significant blood loss compared with SAPF (P < .05), while SAPF resulted in significantly larger operative incision length than SAPP and PSCIF (P < .05). Moreover, patients' stay time was prolonged in both SAPF and SAPP groups than in the PSCIF group (P < .05). Patients who received PSCIF exhibited significantly higher Matta and Majeed scores than those who received SAPF (all P < .05). Finally, SAPP was associated with fewer complications than SAPF, and complications were barely observed in the PSCIF group. CONCLUSION PSCIF may be more appropriate for patients with unstable pelvic fractures in comparison with SAPP and SAPF. Besides, SAPP is likely to be more efficacious than SAPF especially for Tile C patients.
Collapse
Affiliation(s)
- Ronghe Gu
- Department of Orthopedics, The First People's Hospital of Nanning, Nanning
| | - Weiguo Huang
- Department of Orthopedics, The First People's Hospital of Nanning, Nanning
| | - Lijing Yang
- Department of Orthopedics, The First People's Hospital of Nanning, Nanning
| | - Huijiang Liu
- Department of Orthopedics, The First People's Hospital of Nanning, Nanning
| | - Kegong Xie
- Department of Orthopedics, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, Guangxi, China
| | - Zonggui Huang
- Department of Orthopedics, The First People's Hospital of Nanning, Nanning
| |
Collapse
|
22
|
Is there a clinical benefit of additional tension band wiring in plate fixation of the symphysis? BMC Musculoskelet Disord 2017; 18:40. [PMID: 28122599 PMCID: PMC5264461 DOI: 10.1186/s12891-017-1418-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2016] [Accepted: 01/18/2017] [Indexed: 02/08/2023] Open
Abstract
Background The purpose of this study was to determine whether additional tension band wiring in the plate for traumatic disruption of symphysis pubis has clinical benefits. Therefore, outcomes and complications were compared between a plate fixation group and a plate with tension band wiring group. Methods We retrospectively evaluated 64 consecutive patients who underwent open reduction and internal fixation of the symphysis pubis by using a plate alone (n = 39) or a plate with tension band wiring (n = 25). All the patients were followed up for a minimum of 24 months (mean, 34.4 months; range, 26–39 months). Demographic characteristics, outcomes, movement of the metal works, complications, revision surgery, and Majeed functional score were compared. Results Significant screw pullout was relatively significantly more frequently found in the plate fixation group than in the plate with tension band wiring group (P = 0.009). In terms of the overall rate of all-cause revision surgery, including significant loosening, symptomatic hardware, and patient-requested hardware removal during follow-up period, the plate with tension band wiring group showed a significantly lower rate. Conclusion Tension band wiring in combination with a symphyseal plate showed better radiological outcomes, a lower incidence of hardware loosening, and a lower rate of revision surgery than plate fixation alone. This technique would have some potential advantages in terms of avoiding significant movement of plate, symptomatic hardware failure, and revision surgery.
Collapse
|
23
|
Nambiar M, Heaton SR, Stevenson AJ, Bucknill AT. Prominent metalware from pelvic surgery causing dyspareunia. BMJ Case Rep 2017; 2017:bcr2016217285. [PMID: 28062423 PMCID: PMC5256533 DOI: 10.1136/bcr-2016-217285] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/19/2016] [Indexed: 11/04/2022] Open
Abstract
We present a case of female dyspareunia secondary to metalware placement during extensive pelvic surgery following a motor vehicle accident. The patient initially had an uneventful recovery from her operations. However, she noticed pain with vaginal intercourse, due to a screw tip which was palpable on vaginal examination. X-ray imaging confirmed long screws in the medial part of an anterior column plate, which were impacting on the anterior vaginal wall. Subsequent percutaneous removal of two screws resulted in resolution of her symptoms of painful vaginal intercourse. While the pain from mechanical irritation of the vagina was resolved, the patient continues to have difficulty with intercourse, which is related to hip pain as a result of her initial injury and complex pelvic surgery.
Collapse
Affiliation(s)
- Mithun Nambiar
- Department of Orthopaedic Surgery, The Royal MelbourneHospital, Parkville, Victoria, Australia
| | - Samuel Raymond Heaton
- Department of Orthopaedic Surgery, The Royal MelbourneHospital, Parkville, Victoria, Australia
| | - Andrew John Stevenson
- Department of Orthopaedic Surgery, The Royal MelbourneHospital, Parkville, Victoria, Australia
| | - Andrew Thomas Bucknill
- Department of Orthopaedic Surgery, The Royal MelbourneHospital, Parkville, Victoria, Australia
- Department of Surgery (RMH), The University of Melbourne, Royal Melbourne Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
24
|
Abstract
OBJECTIVE To evaluate the influence of the symphyseal position at union, implant failure, and the type of posterior ring injury on validated outcome measures. DESIGN Retrospective review with prospectively collected validated outcome data. SETTING Two academic level 1 trauma centers. PATIENTS/PARTICIPANTS We evaluated 54 patients with operatively treated anterior-posterior compression (APC) type 2 and 3 injuries. INTERVENTION Thirty-five APC type 2 and 19 APC type 3 injuries were reviewed at a minimum of 2 years after surgery. Average follow-up was 7 years. MAIN OUTCOME MEASURES Patients were evaluated with validated EuroQol five dimensions (EQ5D), EuroQol health index, Visual Analog Score (VAS) pain, Majeed pelvic scores, and change in work status. The final anterior-posterior (AP) radiograph available was reviewed for implant failure and displacement. Revision surgery was documented based on implant status and displacement at final follow-up. RESULTS There were trends toward better outcomes for APC type 2 for EQ5D and VAS pain. Patients with injury severity score (ISS) >16 had worse reported health, Majeed scores, and VAS pain. Nineteen patients had failure of fixation. There were no differences in any outcome measure; trends toward better Majeed score were found for patients with intact fixation. Displacements >15 mm anteriorly at final follow-up negatively affect outcomes with significantly worse EQ5D, reported health, and Majeed score. Two patients required revision surgery. There were no differences in final outcomes. CONCLUSIONS No significant differences were found for APC type 2 versus type 3 injuries. Higher injury severity score resulted in worse outcomes and more pain. Outcomes were not effected by implant failure; however, major loss of reduction (>15 mm) anteriorly did negatively impact outcomes. Patients with failure who were revised to union did not have worse outcomes. LEVEL OF EVIDENCE Prognostic level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
25
|
Michelitsch C, Nguyen-Kim TDL, Jentzsch T, Simmen HP, Werner CML. Computed tomography-based three-dimensional visualisation of bone corridors and trajectories for screws in open reduction and internal fixation of symphysis diastasis: a retrospective radiological study. Arch Orthop Trauma Surg 2016; 136:1673-1681. [PMID: 27628459 DOI: 10.1007/s00402-016-2568-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Typical stabilisation of pelvic open book injuries consists of plate fixation of the symphysis. No previous literature has been published about the evaluation of screw placement and their trajectory with four oblique 4.5 mm screws using a four-hole plate in symphysis diastasis. The aim of this study was to define insertion points and angles of trajectory for crossed screw placement regardless of any plate design based on an analysis of three-dimensional computed tomography data sets. METHODS One hundred human pelvic CT data sets were collected. Unilateral and bilateral placements of crossed 4.5 mm screws were simulated. Primary outcome measure was successful simulated screw placement without cortical breach. Secondary outcome measures included the anatomical measurements of the screw positions. RESULTS Simulated screw placement of two oblique screws on each side of the pubic symphysis without cortical breach was achieved in all (100 %) cases. There were a total of 400 screw simulations. Medial screws were longer, lateral screws had higher coronal angles, and the distance between both screws was higher on the right side (p < 0.001 each). The lengths of the right lateral, right medial, left lateral, and left medial screws were 44.9, 65.8, 45.4, and 67.4 mm, respectively. The sagittal angles to the dorsal surface area of the pubic rami were 10.5°, 11.1°, 9.0°, and 11.0°. The coronal angles to the vertical axis of the symphysis measured 39.5°, 16.0°, 33.8°, and 16.8°. The distances between these screws and the medial edge of the pubic crest were 33.5, 8.6, 29.5, and 7.3 mm. Furthermore, certain sex- and side-related differences were noted. CONCLUSIONS This series provides results about the feasibility and a detailed anatomical description of crossed screw placement. This is of special interest in pelvic surgery for choosing the entry points, safe screw channel parameters, and trajectories.
Collapse
Affiliation(s)
- Christian Michelitsch
- Department of Surgery, Division of Trauma Surgery, University Hospital, Zurich, Switzerland.
| | - Thi Dan Linh Nguyen-Kim
- Department of Diagnostic and Interventional Radiology, University Hospital, Zurich, Switzerland
| | - Thorsten Jentzsch
- Department of Surgery, Division of Trauma Surgery, University Hospital, Zurich, Switzerland
| | - Hans-Peter Simmen
- Department of Surgery, Division of Trauma Surgery, University Hospital, Zurich, Switzerland
| | - Clément M L Werner
- Department of Surgery, Division of Trauma Surgery, University Hospital, Zurich, Switzerland
| |
Collapse
|
26
|
Kim WY, Jeong JJ, Kang HV, Lee SW. Underestimated Sacroiliac Joint Lesion on Computed Tomography in Pelvic Open-book Injury: A Case Report. Hip Pelvis 2016; 28:49-53. [PMID: 27536644 PMCID: PMC4972879 DOI: 10.5371/hp.2016.28.1.49] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2015] [Revised: 12/29/2015] [Accepted: 12/31/2015] [Indexed: 11/24/2022] Open
Abstract
The classification of anteroposterior compression (APC) injury type is based on using static radiographs, stress radiographs are known as a useful adjunct in classifying type of APC pelvic injuries. According to a recent article, the intraoperative stress examination has led to a change in the treatment plan in more than 25% of patients on 22 patients presumed APC type I (symphyseal diastasis <2.5 cm) injuries. Here authors present a case demonstrating a necessity of intraoperative stress test for excluding concealed posterior ring disruption.
Collapse
Affiliation(s)
- Weon-Yoo Kim
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Jae-Jung Jeong
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Han-Vit Kang
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| | - Se-Won Lee
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Korea
| |
Collapse
|
27
|
Eastman JG, Krieg JC, Routt MLC. Early failure of symphysis pubis plating. Injury 2016; 47:1707-12. [PMID: 27282685 DOI: 10.1016/j.injury.2016.05.019] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 04/30/2016] [Accepted: 05/16/2016] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Operative fixation of a disrupted symphysis pubis helps return alignment and stability to a traumatized pelvic ring. Implant loosening or failure has been demonstrated to commonly occur at some subacute point during the postoperative period. The purpose of this study is to report on a series of patients with traumatic pelvic ring disruptions to determine the incidence and common factors associated with early postoperative symphyseal plate failure before 7 weeks. MATERIALS AND METHODS 126 patients retrospectively identified with unstable pelvic injuries treated with open reduction and plate fixation of the symphysis pubis and iliosacral screw fixation. Preoperative and postoperative radiographs, computed tomography (CT) images, and medical chart were reviewed to determine symphyseal displacement preoperatively and postoperatively, time until plate failure, patient symptoms and symphyseal displacement at failure, subsequent symphyseal displacement, incidence of additional surgery, and patient weight bearing compliance. RESULTS 14 patients (11.1%) sustained premature postoperative fixation failure. 13 patients had anteroposterior compression (APC)-II injuries and 1 patient had an APC-III injury. Preoperative symphyseal displacement was 35.6 millimeters (mm) (20.8-52.9). Postoperative symphyseal space measurement was 6.3mm (4.7-9.3). Time until plate failure was 29days (5-47). Nine patients (64.2%) noted a pop surrounding the time of failure. Symphyseal space measurement at failure was 12.4mm (5.6-20.5). All patients demonstrated additional symphyseal displacement averaging 2.6mm (0.2-9.4). Two patients (14.2%) underwent revision. Four patients (28.5%) were non-compliant. CONCLUSION Premature failure of symphysis pubis plating is not uncommon. In this series, further symphyseal displacement after plate failure was not substantial. The presence of acute symphyseal plate failure alone may not be an absolute indication for revision surgery. Making patient education a priority could lead to decreased postoperative non-compliance and potentially a decreased incidence of implant failure. Posterior pelvic ring fixation aides overall pelvic ring stability and may help minimize further displacement after early postoperative symphyseal plate failure. Further functional outcome and biomechanical studies surrounding early symphyseal plate failure are needed.
Collapse
Affiliation(s)
- Jonathan G Eastman
- Department of Orthopaedic Surgery, University of California, Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA, USA.
| | - James C Krieg
- Department of Orthopaedic Surgery, Thomas Jefferson University, Philadelphia, PA, USA
| | - Milton L Chip Routt
- Department of Orthopaedic Surgery, University of Texas, Health Sciences Center at Houston, TX, USA
| |
Collapse
|
28
|
Abstract
OBJECTIVES To relate the incidence of implant failure after internal anterior fixation of the pelvic ring to functional outcome and the health-related quality of life in patients. DESIGN Retrospective chart and radiographic review. SETTING Level I Trauma center. METHODS We retrospectively identified all patients who were treated with symphyseal plating for traumatic symphyseal diastasis between January 2003 and December 2013. Patients were asked to complete 2 questionnaires, the SF-36 and the Majeed score. A retrospective chart and radiographic control review were performed on all patients. The following data were collected: demographic data and details regarding the pelvic surgery. Computed tomograms were used to determine fracture classification and quality of reduction. Conventional radiographic follow-up were used to detect implant failure. RESULTS A total of 37 patients enrolled the study. Implant failure occurred in 11 (30%) patients resulting in the identification of 2 groups, "implant failure" (n = 11) and "intact implants" (n = 26). The baseline characteristics were equal in both groups. The analysis of the questionnaires revealed that the SF-36 score was not significantly different in any of the dimensions between the both groups. Patients in the implant failure group scored higher on all of the Majeed items, including the total Majeed score, but the difference did not reach statistical significance of P < 0.05. CONCLUSIONS Our study showed comparable results regarding the general health measured by the SF-36 for both groups and higher Majeed scores for patients with implant failure compared with patients with intact implants. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
29
|
Lee JM, Yoon SJ, Park MS, Song KJ. Clinical Outcome of a Precontoured Symphysis Pubis Plate with Tension Band Wiring for Traumatic Symphysis Pubis Rupture in Pelvic Fractures. JOURNAL OF TRAUMA AND INJURY 2016. [DOI: 10.20408/jti.2016.29.1.22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
| | - Sun Jung Yoon
- Trauma-Team, Chonbuk National University Hospital,
- Department of Orthopedic Surgery, Chonbuk National University Hospital,
| | | | - Kyung Jin Song
- Trauma-Team, Chonbuk National University Hospital,
- Department of Orthopedic Surgery, Chonbuk National University Hospital,
| |
Collapse
|
30
|
Surgical Fixation Hardware for Regeneration of Long Bone Segmental Defects: Translating Large Animal Model and Human Experiences. Clin Rev Bone Miner Metab 2015. [DOI: 10.1007/s12018-015-9195-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
31
|
Yu KH, Hong JJ, Guo XS, Zhou DS. Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience. J Orthop Surg Res 2015; 10:151. [PMID: 26391358 PMCID: PMC4578385 DOI: 10.1186/s13018-015-0272-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Accepted: 08/09/2015] [Indexed: 11/10/2022] Open
Abstract
Objective The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Materials and Methods Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. Results The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18–54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. Conclusion PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.
Collapse
Affiliation(s)
- Ke-He Yu
- Department of Traumatic Orthopedics, Shandong Provincial Hospital, Shandong University, No. 324 Jin Wu Wei Seventh Road, Jinan, 250021, Shandong, China.
| | - Jian-Jun Hong
- Department of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, 109# XueYuan Western Road, Wenzhou, Zhejiang, 325000, China.
| | - Xiao-Shan Guo
- Department of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical University, 109# XueYuan Western Road, Wenzhou, Zhejiang, 325000, China.
| | - Dong-Sheng Zhou
- Department of Traumatic Orthopedics, Shandong Provincial Hospital, Shandong University, No. 324 Jin Wu Wei Seventh Road, Jinan, 250021, Shandong, China.
| |
Collapse
|
32
|
Abstract
The art of symphysiotomy for delivery in the instance of cephalopelvic disproportion has been a dying art since the advent of caesarean section but in Ireland this surgical procedure was not abolished until 1992. This practice is still present in the developing world and in some circumstances used in developed countries. This study offers some insights on the 40-year follow-up of patients who had undergone symphysiotomy.
Collapse
Affiliation(s)
- S R Shaarani
- a Orthopaedic Registrar, Department of Orthopaedic Surgery , Cappagh National Orthopaedic Hospital , Finglas, Dublin , Ireland
| | - W van Eeden
- b Medical Student, Royal College of Surgeons in Ireland , Dublin , Ireland
| | - J M O'Byrne
- c Abraham Colles Professor in Orthopaedic and Trauma Surgery, Royal College of Surgeon in Ireland and Cappagh National Orthopaedic Hospital , Dublin , Ireland
| |
Collapse
|
33
|
El Dafrawy MH, Osgood GM. Retrieval of broken iliosacral screws: the power of a push screw. Injury 2015; 46:1411-6. [PMID: 25986663 DOI: 10.1016/j.injury.2015.04.040] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Revised: 02/02/2015] [Accepted: 04/25/2015] [Indexed: 02/02/2023]
Abstract
Percutaneous iliosacral screw fixation is a common technique that is widely used for unstable posterior pelvic ring disruptions. Complications of posterior percutaneous iliosacral screw fixation include implant malpositioning and hardware failure. Removal of iliosacral screws in broken or symptomatic hardware is sometimes necessary. To our knowledge, there are few reports addressing pelvic implant removal, and most of those report on anterior pelvic implants and symphyseal plates. There are no reports describing techniques for retrieval of broken iliosacral screws. We present two cases involving removal of broken sacroiliac screws, review the literature regarding iliosacral implant extraction, and identify important aspects of safe extraction of iliosacral screws and the potential complications associated with their retrieval. We further describe a novel and powerful technique to facilitate percutaneous removal of broken screw fragments, using a "push screw" to drive a broken screw fragment from a position buried in bone.
Collapse
Affiliation(s)
- Mostafa H El Dafrawy
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD, United States
| | - Greg M Osgood
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD, United States.
| |
Collapse
|
34
|
Anatomical measurement and finite element study on screw channel parameter in percutaneous fixation of canulated screw for symphyseolysis. Cell Biochem Biophys 2014; 71:1243-8. [PMID: 25388836 DOI: 10.1007/s12013-014-0335-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
To provide anatomical basement for symphyseolysis treatment with percutaneous fixation of canulated screw, through anatomical measurement on pubic symphysis and the surrounding tissues, and conduct the finite element studies on screw channel parameters. 20 cases of normal pelvic specimens from embalmed adult cadavers were taken to measure the anatomical parameter of bony remark of pubic symphysis and the space between spermatic cord (round ligament of the uterus) and pubic tubercle. Anatomical measurement results showed that the narrowest diameter of the superior ramus of pubis was 9.127 ± 1.189 mm, distance between two pubic tubercles was 55.656 ± 3.780 mm, thickness of the upper pubic symphysis was 10.510 ± 0.814 mm, and distance between upper and lower pubic symphysis was 40.872 ± 1.211 mm; the distance between round ligament of the uterus and pubic tubercle was 4.408 ± 0.304 mm, and the distance between spermatic cord and pubic tubercle was 5.196 ± 0.251 mm. The angle between canulated screw guide pin and horizontal plane was 8.342 ± 2.152°, the one between guide pin and coronal plane was 5.236 ± 1.612°, and the distance from entry point to the outer edge of pubic tubercle was 10.023 ± 1.245 mm, which was measured by Mimics software. Percutaneous surgery at horizontal position was simulated on cadaver. And the screw was correctly placed in postoperative imaging examination. According to the anatomical data and finite element studies of screw channel parameter in percutaneous fixation of canulated screw for symphyseolysis, the method can improve the accuracy of screw placement and reduce complications.
Collapse
|
35
|
Stuby FM, Doebele S, Agarwal Y, Windolf M, Gueorguiev B, Ochs BG. Influence of flexible fixation for open book injury after pelvic trauma--a biomechanical study. Clin Biomech (Bristol, Avon) 2014; 29:657-63. [PMID: 24852652 DOI: 10.1016/j.clinbiomech.2014.04.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Revised: 04/14/2014] [Accepted: 04/22/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND Implant loosening is frequently detected after fixation of open book injuries. Though many authors do not see this as a complication, it is often the reason for hardware removal or reinstrumentation in the case of remaining instability. We hypothesized that the flexibility of the implant has an influence on loosening and thus on failure of the construct. METHODS We used 6 fresh-frozen pelvic specimens and tested them with our recently introduced test setup for two-leg alternate loading. We subjected them to a non-destructive quasi-static test in the intact condition followed by a non-destructive cyclic test under axial sinusoidal loading with progressive amplitude. Afterwards we simulated an open book injury and performed fixation with three different configurations of a modular fixation system (1-, 2- or 4-rod configuration) in randomized order. Subsequently, the specimens were subjected to 3 cyclic tests with the same loading protocol as previously defined. Finally, each construct was cyclically tested to failure keeping the final rod configuration. FINDINGS We detected significantly greater mobility after 1-rod-fixation and no significant differences after 2-rod or 4-rod-fixation compared to the intact symphysis condition. In the destructive test series the 4-rod-fixation failed first followed by the 1-rod-fixation. The 2-rod-fixation sustained almost 3 times as many load cycles prior to failure as the 4-rod-fixation, whereas the 1-rod-fixation sustained twice as many cycles as the 4-rod-fixation. INTERPRETATION In conclusion, flexible fixation of the ruptured pubic symphysis in human specimens shows superior behavior with respect to load bearing capacity and ability to withstand cyclic loading compared to stiff constructs.
Collapse
Affiliation(s)
- Fabian M Stuby
- BG Trauma Center, Eberhard Karls University, Schnarrenbergstrasse 95, D-72076 Tuebingen, Germany.
| | - Stefan Doebele
- BG Trauma Center, Eberhard Karls University, Schnarrenbergstrasse 95, D-72076 Tuebingen, Germany.
| | - Yash Agarwal
- AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos, Switzerland.
| | - Markus Windolf
- AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos, Switzerland.
| | - Boyko Gueorguiev
- AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos, Switzerland.
| | - Bjoern Gunnar Ochs
- BG Trauma Center, Eberhard Karls University, Schnarrenbergstrasse 95, D-72076 Tuebingen, Germany.
| |
Collapse
|
36
|
Pizanis A, Garcia P, Santelmann M, Culemann U, Pohlemann T. Reduction and fixation capabilities of different plate designs for pubic symphysis disruption: a biomechanical comparison. Injury 2013; 44:183-8. [PMID: 23068141 DOI: 10.1016/j.injury.2012.09.023] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Revised: 06/05/2012] [Accepted: 09/24/2012] [Indexed: 02/02/2023]
Abstract
BACKGROUND Typical stabilisation of pelvic open book injuries consists in plate fixation of the symphysis, leading to many different plate designs and procedures that have evolved. However, implant loosening and development of chronic instability are still evident and represent major complications after plate fixation of the symphysis. The aim of this study was to analyse reduction and fixation capabilities of different classical plate techniques with dynamic compression (DC), prebending or modern interlocking screws. METHODS Compression injuries (OTA B1.1) were simulated on synthetic composite pelvises. Sensor films placed in the disrupted symphysis allowed assessment of reduction and compression forces, as well as contact characteristics by implants at defined time points under static non loaded conditions. The commercially available steel plates used in our study differed in curved design, prebending and DC- or locking screw capabilities, as narrow large fragment (4.5) or small fragment plates (3.5). RESULTS DC procedure clearly increased the compressive force in the symphysis and improved the reduction by enhanced contact areas. These effects were preserved to the end of the experiments only when the plates were prebended (10°). Anatomically contoured and prebended 3.5 plates had a similar effect, but the contact area was even more pronounced. Best results were observed using the "3.5 symphyseal plate" with DC-effect medially and locking screws laterally. Purely interlocking screw plates by themselves allowed an optimal contact area, yet failed to preserve the initial compressive reduction force. CONCLUSIONS The experimental results suggest a biomechanical advantage in using prebended plates for symphysis fixation compared to non-bended plates. Best results with regard to compression and increased contact area can be achieved by anatomically contoured plates with combined DC and locking screw capabilities. These findings are of special interest in pelvic surgery for choosing the right implant in severe displacements, obese patients and symphysiodesis techniques.
Collapse
Affiliation(s)
- Antonius Pizanis
- Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital of Saarland, D-66424 Homburg/Saar, Germany.
| | | | | | | | | |
Collapse
|
37
|
Hechtman KS, Zvijac JE, Popkin CA, Zych GA, Botto-van Bemden A. A minimally disruptive surgical technique for the treatment of osteitis pubis in athletes. Sports Health 2012; 2:211-5. [PMID: 23015940 PMCID: PMC3445106 DOI: 10.1177/1941738110366203] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Background: Multiple surgical procedures exist for the treatment of osteitis pubis: curettage of the symphysis joint, wedge resection, complete resection of the joint, placement of extraperitoneal retropubic synthetic mesh, and arthrodesis of the joint. However, a paucity of literature has reported long-term successful outcomes with the aforementioned approaches. Patients treated operatively have reported recalcitrant pain resulting from iatrogenic instability. The article presents the results of a conservative operative technique that avoids disruption of adjacent ligaments. Hypothesis: Preserving the adjacent ligamentous structures will allow competitive athletes to return to competition and activities of daily living free of iatrogenic pelvic instability and pain. Study Design: Case series. Methods: Four competitive athletes (2 professional and 2 collegiate football players) diagnosed with osteitis pubis were treated conservatively for a minimum of 6 months. Patients underwent surgical intervention upon failure to respond to nonoperative management. The degenerative tissue was resected, allowing only bleeding cancellous bone to remain while preserving the adjacent ligaments. An arthroscope was used to assist in curettage, allowing the debridement to be performed through a small incision in the anterior capsule. Results: The symptoms of all 4 patients resolved, and they returned to competitive athletics. This ligament-sparing technique provided a solid, stable repair and pain relief. Conclusion: This surgical technique preserves the adjacent ligamentous structures and allows competitive athletes to return to competition and activities of daily living free of pain and void of pelvic instability. Clinical Relevance: This technique is a surgical treatment option for athletes with osteitis pubis who fail conservative treatment.
Collapse
|
38
|
Stuby FM, Gonser CE, Baron HC, Stöckle U, Badke A, Ochs BG. [Hardware removal after pelvic ring injury]. Unfallchirurg 2012; 115:330-8. [PMID: 22476342 DOI: 10.1007/s00113-012-2157-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Pelvic ring fractures are considered as rare injuries. Minimally invasive sacroiliac screw fixation has been used increasingly in recent years as an operative strategy for the treatment of these injuries, if the dorsal pelvic ring needed to be addressed. Treatment options for the anterior pelvic ring comprise plates, screws or external fixation. METHOD Based on the limited number of publications on this subject and our own experience with 80 patients who suffered pelvic ring B- or C-type injuries during a period of 8 years we are able to show that the indication for hardware removal in the pelvic ring should be strictly defined. RESULTS In some cases like external fixation, implant-associated infection, malpositioning, allergic implant reaction, critical soft tissue covering, palpable hardware and consolidated juvenile fractures implant removal is certainly indicated. In patients without symptoms and in patients with trauma-associated symptoms which are not definitely associated with the hardware, the removal should be only indicated after thorough consideration of the risks versus the benefits and additionally by taking the initial injury pattern into account. If despite all these objections the hardware removal has been indicated it should always be considered that hardware removal may be challenging with several possible severe complications.
Collapse
Affiliation(s)
- F M Stuby
- Klinik für Unfall- und Wiederherstellungschirurgie, Berufsgenossenschaftliche Unfallklinik Tübingen, Eberhard Karls-Universität Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Deutschland
| | | | | | | | | | | |
Collapse
|
39
|
Collinge C, Archdeacon MT, Dulaney-Cripe E, Moed BR. Radiographic changes of implant failure after plating for pubic symphysis diastasis: an underappreciated reality? Clin Orthop Relat Res 2012; 470:2148-53. [PMID: 22552765 PMCID: PMC3392370 DOI: 10.1007/s11999-012-2340-5] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Implant failure after symphyseal disruption and plating reportedly occurs in 0% to 21% of patients but the actual occurrence may be much more frequent and the characteristics of this failure have not been well described. QUESTIONS/PURPOSES We therefore determined the incidence and characterized radiographic implant failures in patients undergoing symphyseal plating after disruption of the pubic symphysis. METHODS We retrospectively reviewed 165 adult patients with Orthopaedic Trauma Association (OTA) 61-B (Tile B) or OTA 61-C (Tile C) pelvic injuries treated with symphyseal plating at two regional Level I and one Level II trauma centers. Immediate postoperative and latest followup anteroposterior radiographs were reviewed for implant loosening or breakage and for recurrent diastasis of the pubic symphysis. The minimum followup was 6 months (average, 12.2 months; range, 6-65 months). RESULTS Failure of fixation, including screw loosening or breakage of the symphyseal fixation, occurred in 95 of the 127 patients (75%), which resulted in widening of the pubic symphyseal space in 84 of those cases (88%) when compared with the immediate postoperative radiograph. The mean width of the pubic space measured 4.9 mm (range, 2-10 mm) on immediate postoperative radiographs; however, on the last radiographs, the mean was 8.4 mm (range, 3-21 mm), representing a 71% increase. In seven patients (6%), the symphysis widened 10 mm or more; however, only one of these patients required revision surgery. CONCLUSIONS Failure of fixation with recurrent widening of the pubic space can be expected after plating of the pubic symphysis for traumatic diastasis. Although widening may represent a benign condition as motion is restored to the pubic symphysis, patients should be counseled regarding a high risk of radiographic failure but a small likelihood of revision surgery. LEVEL OF EVIDENCE Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Cory Collinge
- Harris Methodist Fort Worth Hospital and John Peter Smith Orthopaedic Surgery Residency Program, 800 5th Street, Suite 500, Fort Worth, TX 76104 USA
| | - Michael T. Archdeacon
- Department of Orthopaedic Surgery, University of Cincinnati Academic Medical Center, Cincinnati, OH USA
| | - Elizabeth Dulaney-Cripe
- Department of Orthopaedic Surgery, Boonshoft School of Medicine, Wright State University, Dayton, OH USA
| | - Berton R. Moed
- Department of Orthopaedic Surgery, Saint Louis University School of Medicine, St Louis, MO USA
| |
Collapse
|
40
|
Abstract
BACKGROUND Plate fixation is a recognized treatment for pelvic ring injuries involving disruption of the pubic symphysis. Although fixation failure is well known, it is unclear whether early or late fixation failure is clinically important. QUESTIONS/PURPOSES We therefore determined (1) the incidence and mode of failure of anterior plate fixation for traumatic pubic symphysis disruption; (2) whether failure of fixation was associated with the types of pelvic ring injury or pelvic fixation used; (3) the complications, including the requirement for reoperation or hardware removal; and (4) whether radiographic followup of greater than 1 year alters subsequent management. METHODS We retrospectively reviewed 148 of 178 (83%) patients with traumatic symphysis pubis diastasis treated by plate fixation between 1994 and 2008. Routine radiographic review, pelvic fracture classification, method of fixation, incidence of fixation failure, timing and mode of failure, and the complications were recorded after a minimum followup of 12 months (mean, 45 months; range, 1-14 years). RESULTS Hardware breakage occurred in 63 patients (43%), of which 61 were asymptomatic. Breakage was not related to type of plate, fracture classification, or posterior pelvic fixation. Five patients (3%) required revision surgery for failure of fixation or symptomatic instability of the symphysis pubis, and seven patients (5%) had removal of hardware for other reasons, including late deep infection in three (2%). Routine radiographic screening as part of annual followup after 1 year did not alter management. CONCLUSIONS Our observations suggest the high rate of late fixation failure after plate fixation of the symphysis pubis is not clinically important.
Collapse
|
41
|
Putnis SE, Pearce R, Wali UJ, Bircher MD, Rickman MS. Open reduction and internal fixation of a traumatic diastasis of the pubic symphysis: one-year radiological and functional outcomes. ACTA ACUST UNITED AC 2011; 93:78-84. [PMID: 21196548 DOI: 10.1302/0301-620x.93b1.23941] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The aim of this study was to review the number of patients operated on for traumatic disruption of the pubic symphysis who developed radiological signs of movement of the anterior pelvic metalwork during the first post-operative year, and to determine whether this had clinical implications. A consecutive series of 49 patients undergoing internal fixation of a traumatic diastasis of the pubic symphysis were studied. All underwent anterior fixation of the diastasis, which was frequently combined with posterior pelvic fixation. The fractures were divided into groups using the Young and Burgess classification for pelvic ring fractures. The different combinations of anterior and posterior fixation adopted to stabilise the fractures and the type of movement of the metalwork which was observed were analysed and related to functional outcome during the first post-operative year. In 15 patients the radiographs showed movement of the anterior metalwork, with broken or mobile screws or plates, and in six there were signs of a recurrent diastasis. In this group, four patients required revision surgery; three with anterior fixation and one with removal of anterior pelvic metalwork; the remaining 11 functioned as well as the rest of the study group. We conclude that radiological signs of movement in the anterior pelvic metalwork, albeit common, are not in themselves an indication for revision surgery.
Collapse
Affiliation(s)
- S E Putnis
- Department of Trauma and Orthopaedic Surgery, St George's Hospital, Blackshaw Road, London SW17 0QT, UK.
| | | | | | | | | |
Collapse
|
42
|
Stress radiograph to detect true extent of symphyseal disruption in presumed anteroposterior compression type I pelvic injuries. ACTA ACUST UNITED AC 2010; 69:880-5. [PMID: 20938276 DOI: 10.1097/ta.0b013e3181efbad5] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The differentiation between anteroposterior compression (APC)-I and APC-II pelvic fracture patterns is critical in determining operative versus nonoperative treatment. We instituted a protocol in which a stress examination was performed for patients presenting with an APC-I injury diagnosed with static radiographs to reveal the true extent of the injury. METHODS During a 4-year study period, we performed 22 stress radiographs in patients with a presumed APC-I injury, which showed symphyseal diastasis ≥ 1.0 cm but <2.5 cm on initial anteroposterior (AP) radiographs of the pelvis or on axial images of the pelvis on computed tomography (CT) scans. In the operating room, a radiopaque marker of known diameter was placed on the skin over the pubic symphysis. A direct AP load was manually applied to both anterior superior iliac spines, and diastasis of the pubic symphysis was measured on stress fluoroscopic images. RESULTS The mean distance of symphyseal diastasis was 1.8 cm on the AP radiographs, 1.4 cm on the CT scans, and 2.5 cm on fluoroscopic images under a stress examination. Six of 22 patients (27.2%) demonstrated a symphyseal diastasis of >2.5 cm during the stress examination, which changed their treatment from nonoperative to operative. CONCLUSIONS Measurements of symphyseal diastasis can significantly vary depending on the radiographic modality (CT vs. plain films) and during application of a stress force. The use of stress examination under general anesthesia in the acute setting of pelvic injury can be beneficial in accurately diagnosing the severity of injury and choosing appropriate treatment.
Collapse
|