1
|
Quantification of the Safe Zone of the First to Third Sacral Segments for Transiliac-Transsacral Screw Fixation in Normal and Dysmorphic Sacra. Orthopedics 2024; 47:e13-e18. [PMID: 37276441 DOI: 10.3928/01477447-20230531-06] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Transiliac-transsacral screw fixation is widely used to stabilize unstable posterior pelvic ring injuries. Preoperative radiographic assessment of the safe osseous corridor is necessary because the safe space of sacrum is narrower for transiliac-transsacral screw placement than for traditional iliosacral screw placement. However, the radiographic assessment has rarely been studied in the Taiwanese population. We retrospectively analyzed 100 patients with pelvic computed tomography images and divided them into normal and dysmorphic pelvis groups. To determine the safe osseous space, we recorded cross-section area, cross-sectional diameter of the safe zone (CS-szD), and safe zone width on axial view (Ax-szW) in the S1 to S3 segments. The prevalence of dysmorphic pelvis was 48% among all patients. In the S1 segment, no differences were found in the cross-section area and CS-szD been the two groups. However, the Ax-szW was significantly smaller in the dysmorphic pelvis group. In the S2 segment, the cross-section area, CS-szD, and Ax-szW were all significantly larger in the dysmorphic pelvis group. In the S3 segment, the cross-section area and CS-szD of the normal pelvis group were both significantly smaller. No differences were found in the Ax-szW between the two groups. Based on our findings in a Taiwanese population, S1 was the most suitable segment for transiliac-transsacral screw fixation in a normal pelvis, whereas S2, followed by S3, was most suitable in a dysmorphic pelvis. This study offers surgeons information on identifying the optimal sacral segment for transiliac-transsacral screw placement for each pelvic morphology. [Orthopedics. 2024;47(1):e13-e18.].
Collapse
|
2
|
Comparison of primary total hip arthroplasty with limited open reduction and internal fixation vs open reduction and internal fixation for geriatric acetabular fractures: a systematic review and meta-analysis. EFORT Open Rev 2023; 8:532-547. [PMID: 37395715 DOI: 10.1530/eor-21-0099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/04/2023] Open
Abstract
Purpose Comminuted fractures with poor bone quality in the elderly are associated with poor outcomes. An alternative to open reduction and internal fixation (ORIF) alone, primary or acute total hip arthroplasty (aTHA), allows early mobilization with full weight bearing. In this study, we aim to analyze whether treatment of aTHA with/withtout ORIF (limited ORIF) vs ORIF alone yields better intra-operative results, functional outcomes, and less complications. Methods PubMed, Cochrane, Embase, and Scopus databases were searched in accordance with the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) guidelines. Random-effects model and 95% confidence intervals were used. The outcomes of interest were surgery time, blood loss, length of hospital stay, Harris hip score (HHS), 36-Item Short Form Survey (SF-36), complication rate, surgical site infection rate, heterotopic ossification rate, reoperation rate, and mortality rate. Results Ten observational studies with a total of 642 patients (415 ORIF alone and 227 aTHA with/without ORIF) were included in the systematic review. Compared to ORIF alone, aTHA with limited ORIF provided higher HHS (P = 0.029), better physical function (P = 0.008), better physical component summary (P = 0.001), better mental component summary (P = 0.043) in postoperative 1-year SF-36, lesser complication rate (P = 0.001), and lesser reoperation rate (P = 0.000), but however greater bodily pain (P = 0.001) in acetabular fractured elderlies. Conclusions Acute THA with limited ORIF is favorable alternative to ORIF technique alone. It provided better HHS, physical, and mental component summary in SF-36 and yielded lower complication and reoperation rate compare to ORIF alone.
Collapse
|
3
|
The radiographic outcome after plating for pubic symphysis diastasis: does it matter clinically? Arch Orthop Trauma Surg 2023; 143:1965-1972. [PMID: 35278092 PMCID: PMC10030392 DOI: 10.1007/s00402-022-04411-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 02/26/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Open reduction and internal fixation with plates is the most widespread surgery in traumatic pubic symphysis diastasis. However, implant failure or recurrent diastasis was commonly observed during follow-up. The aim of our study was to evaluate the radiologic findings and clinical outcomes. MATERIALS AND METHODS Sixty-five patients with traumatic pubic symphysis diastasis treated with plating between 2008 and 2019 were retrospectively reviewed. The exclusion criteria were a history of malignancy and age under 20 years. Radiographic outcomes were determined by radiograph findings, including pubic symphysis distance (PSD) and implant failure. Clinical outcomes were assessed according to the Majeed score at the final follow-up. RESULTS Twenty-eight patients were finally included. Nine patients (32%) experienced implant failure, including four (14%) with screw loosening and five (18%) with plate breakage. Only one patient underwent revision surgery. Postoperatively, a significant increase in PSD was observed at 3 months and 6 months. Postoperative PSD was not significantly different between patients with single plating and double plating, but it was significantly greater in the implant-failure group than in the non-failure group. The Majeed score was similar between patients with single plating and double plating or between the implant-failure group and the non-failure group. Body mass index, number of plates, age, and initial injured PSD were not significantly different between the implant-failure group and the non-failure group. Only a significant male predominance was observed in the implant-failure group. CONCLUSION A gradual increase in the symphysis distance and a high possibility of implant failure may be the distinguishing features of traumatic pubic symphysis diastasis fixation. The postoperative symphyseal distance achieved stability after 6 months, even after implant failure. Radiographic outcomes, such as increased symphysis distance, screw loosening, and plate breakage, did not affect clinical functional outcomes.
Collapse
|
4
|
Using Trident distal radial locking plate to fix the fracture of distal radius volar rim. J Chin Med Assoc 2023; 86:426-430. [PMID: 36661280 DOI: 10.1097/jcma.0000000000000881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
BACKGROUND The volar locking plates have been widely used in a variety of distal radius fractures, but they still have several limitations when dealing with small fragments located around the watershed line with widely reported complications. The volar rim fragments play a critical role in radiocarpal joint stability and failing to secure the volar rim fragment usually results in carpal instability, subluxation, or even dislocation. This study investigates clinical outcomes in the use of a novel implant, the Trident distal radial (TDR) locking plate to treat distal radius fracture with the intermedium column edge (lunate fossa volar rim) fragment involvement. METHODS A retrospective study of 25 patients was conducted, all patients had intermedium column fractures with lunate fossa volar rim involvement and treat with the TDR between January 2016 and December 2019. The clinical assessment outcomes included VAS Pain, PRWE, and DASH scores. Objective measurements included ROM of the injured wrist and grip strength. Final radiographs were used to evaluate radial inclination, volar tilt, ulnar variance, and distal radioulnar joint instability. Secondary operations related to hardware complications were also recorded. RESULTS The outcome revealed that the mean VAS Pain Score was 1.3, mean DASH score was 10.5, and mean PRWE score was 9.3. Objective measurements revealed good ROM recovery and an 89% gripping strength recovery compared with contralateral hand. Radiographic measurements revealed good maintenance of volar tilt, radial inclination, and mean ulnar variance. There were no complications related to the implant and all fracture sites were union. CONCLUSION We believe that the TDR provided more stable fixation among distal radial fractures that predominantly involved the intermedial column and volar rim fragment, and allowing early rehabilitation. We could obtain excellent results in the wrist ROM, gripping power, and Pain Score (VAS).
Collapse
|
5
|
"Fragment Width Ratio" as a Predictor of Nonunion for Femoral Shaft Fracture With Third Fragments. Orthopedics 2023; 46:169-174. [PMID: 37018623 DOI: 10.3928/01477447-20230104-08] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
Previous studies have reported that large fracture fragment with displacement might cause nonunion of femoral shaft fractures. We therefore intended to delineate significant risk factors for developing a nonunion predisposed by a major fracture fragment. We analyzed 61 patients who were operated on using interlocking nails for femoral shaft fractures from 2009 to 2018. We classified patients with modified Radiographic Union Scale for Tibia fractures scores of less than 11 or needing reoperations by 1 year postoperatively as nonunion. We thereafter measured parameters of the displaced fracture fragment and fracture site to identify the significant difference between the union and non-union groups. We also applied the receiver operating characteristic curve to demonstrate a threshold value for the fragment width (FW) ratio. Among 61 patients with complete follow-up, no significant difference was found regarding length, displacement, and angulation of fragments between patients with and without union. Except for higher mean FW (P=.03) and the FW ratio (P=.01) in patients with nonunion, the logistic regression analysis demonstrated that FW ratio significantly affected union (P=.018; odds ratio, 0.21; 95% CI, 0.001-0.522). Although a fracture fragment greater than 4 cm with displacement greater than 2 cm was reported to significantly cause nonunions, our study showed that an FW ratio greater than 0.55 instead of fragment size or displacement was predictive for the occurrence of nonunion adjoining to the fracture site. Fixation of the third fracture fragment should not be ignored for preventing a nonunion. More attention should be paid to achieve a better fixation for a major fracture fragment with an FW ratio greater than 0.55 to avoid the development of non-union following the use of interlocking nail for femoral shaft fracture. [Orthopedics. 202x;xx(x):xx-xx.].
Collapse
|
6
|
May-Thurner Syndrome Following Left Lower Extremity Surgery. J Foot Ankle Surg 2022; 61:920-921. [PMID: 31053382 DOI: 10.1053/j.jfas.2018.11.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2018] [Indexed: 02/03/2023]
|
7
|
Combining a transosseous cerclage wire after patellar tendon reattachment to treat patella distal pole fracture did not improve functional outcome. Sci Rep 2022; 12:9587. [PMID: 35688938 PMCID: PMC9187669 DOI: 10.1038/s41598-022-13641-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 05/26/2022] [Indexed: 11/24/2022] Open
Abstract
This study aims to investigate whether an augmented wire in the treatment of patella distal pole fracture could improve knee range of motion (ROM) and radiographic features. Thirty-five consecutive patients with patellar distal pole fracture were analyzed from January 2014 to July 2019. The treatment is divided into two groups according to the presence or absence of augmented wire. Knee ROM, bone union, extension lag, and patellar height were compared between these two groups as the clinical and radiological outcomes. There was no significant difference in mean knee ROM (110° vs. 108°, p = 0.79), proportion of patella baja or bone union. More extension lag was noted in the augmentation group (5/20, 25%) than in the tendon reattachment group (1/15, 6.7%) with no statistically significant difference. In the augmentation group, four cases (20%) would need to remove the fixator due to irritation or broken hardware. Maintaining the patella length by preserving the distal pole and repairing the torn retinaculum allowed early motion to avoid knee stiffness safely without augmentation wire, which doesn’t improve knee ROM. The patellar tendon reattachment alone could achieve a great recovery and prevent the need for a second surgery due to broken wire or irritation.
Collapse
|
8
|
Revealing directed effective connectivity of cortical neuronal networks from measurements. Phys Rev E 2022; 105:044406. [PMID: 35590680 DOI: 10.1103/physreve.105.044406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 03/23/2022] [Indexed: 06/15/2023]
Abstract
In the study of biological networks, one of the major challenges is to understand the relationships between network structure and dynamics. In this paper, we model in vitro cortical neuronal cultures as stochastic dynamical systems and apply a method that reconstructs directed networks from dynamics [Ching and Tam, Phys. Rev. E 95, 010301(R) (2017)2470-004510.1103/PhysRevE.95.010301] to reveal directed effective connectivity, namely, the directed links and synaptic weights, of the neuronal cultures from voltage measurements recorded by a multielectrode array. The effective connectivity so obtained reproduces several features of cortical regions in rats and monkeys and has similar network properties as the synaptic network of the nematode Caenorhabditis elegans, whose entire nervous system has been mapped out. The distribution of the incoming degree is bimodal and the distributions of the average incoming and outgoing synaptic strength are non-Gaussian with long tails. The effective connectivity captures different information from the commonly studied functional connectivity, estimated using statistical correlation between spiking activities. The average synaptic strengths of excitatory incoming and outgoing links are found to increase with the spiking activity in the estimated effective connectivity but not in the functional connectivity estimated using the same sets of voltage measurements. These results thus demonstrate that the reconstructed effective connectivity can capture the general properties of synaptic connections and better reveal relationships between network structure and dynamics.
Collapse
|
9
|
[Analysis of the Effects of Femoral Nerve Block on Pain Level and Knee Mobility in Patients With Total Knee Replacement]. HU LI ZA ZHI THE JOURNAL OF NURSING 2022; 69:32-43. [PMID: 35318631 DOI: 10.6224/jn.202204_69(2).06] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
BACKGROUND Osteoarthritis is a common cause of inactivity and reduced quality of life in the elderly. Total knee replacement (TKR) surgery, a last-stage treatment option for osteoarthritis, often results in postoperative pain that influences knee flexion and the ability to perform prescribed rehabilitation exercises. PURPOSE This study was designed to examine the effectiveness of single femoral nerve block (FNB) on pain level and knee mobility in patients with TKR. METHODS A quasi-experimental, two-group, longitudinal study was designed. The participants were distributed into the FNB group (n = 86) and non-FNB group (n = 86). The outcome measurements included pain scale (Numerical Rating Scale) score and knee continuous passive motion knee flexion angle. The five assessments and followed-up times were as follows: admission day (T0) and post-surgery day 1, 2, 3, and 4. RESULTS The results of the generalized estimating equations model showed that the pain level in the FNB group was significantly lower than in the non-FNB group, (p < .001). In terms of analgesics demand from post-surgery day 1 to day 4, the FNB group exhibited a significantly lower demand than the non-FNB group (p < .01). In addition, significant differences in the continuous passive motion rehabilitation exercise angle were found between the two groups from post-surgery day 1 through day 4 (p < .05). Finally, significant differences in knee flexion angles between the two groups were observed between hospital admission and discharge (p < .001). CONCLUSIONS / IMPLICATIONS FOR PRACTICE The findings of this study support the positive effects of the femoral nerve block intervention on patients who receive total knee replacement surgery. The results were significant in terms of pain relief and knee mobility recovery. This intervention should be made available for use in the clinical care of TKR patients.
Collapse
|
10
|
Single pulley double-strand anchor suture fixation of the coronoid process in terrible triad of the elbow injury. J Chin Med Assoc 2022; 85:222-227. [PMID: 34643618 DOI: 10.1097/jcma.0000000000000633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Terrible triad of the elbow injury is difficult to manage, and the role of the coronoid process in instability is very important. We describe a simple, modified suture technique to fix a coronoid process fragment using suture anchor fixation. METHODS Eight patients (three female and five male) with coronoid process injuries with the fragment involving <50% of the total height (Regan-Morrey type I/II) in terrible triad of elbow injury were included. Patients were treated operatively via a lateral Kocher's approach, and coronoid process fractures were repaired with a single pulley double-strand suture technique. Structures were addressed in a sequential fashion-the coronoid process, radial head, lateral ulnar collateral ligament. RESULTS All patients were treated with the single pulley double-strand anchor suture technique and the coronoid process fragment was found to be in good contact with the original avulsion site using the method. The final Mayo Elbow Performance Score was excellent (> 90) in six patients and good (between 85 and 89) in two patients after operation 6 months. CONCLUSION The single pulley double-strand suture tie method using a suture anchor is a less invasive and simpler fixation method for the repair of coronoid process fractures in patients with terrible triad of the elbow injuries and results in good outcomes.
Collapse
|
11
|
Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study. BMC Musculoskelet Disord 2022; 23:18. [PMID: 34980102 PMCID: PMC8725281 DOI: 10.1186/s12891-021-04984-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Accepted: 12/21/2021] [Indexed: 11/10/2022] Open
Abstract
Introduction The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggested. On the other hand, marginal distal radius fracture patterns required the plate to cross the watershed line, making conflict over plate positioning on marginal distal radius fractures. This study compared functional outcomes in patients with marginal distal radius fractures treated with two different implants. Materials and methods A retrospective study was conducted, all patients who received a Synthes 2.4 mm LCP or an Acumed Acu-Loc VLP between January 2015 and December 2018 were reviewed. The marginal distal radius fracture pattern was the most distal horizontal fracture line within 10 mm of the lunate fossa’s joint line. The primary outcomes including patient-reported pain scores, range of motion, and grip strength were assessed. Secondary outcomes included patient-based subjective satisfaction scores of the injured wrist and hand function. The Mayo Wrist Score and the requirement for a secondary procedure related to hardware complications were also recorded. Results Forty-two patients met our inclusion criteria. Twenty-one patients were treated with the Synthes 2.4 mm LCP, and 21 patients with the Acumed Acu-Loc VLP. The primary outcome revealed that post-operative range of motion (P = 0.016) and grip strengths (P = 0.014) were significantly improved in the Acu-Loc VLP group. The MAYO wrist score in the Acu-Loc VLP group was also significantly better (P = 0.006). Conclusions Despite advances in implant designs, flexor tendon irritation or rupture is still a complication following distal radius’s volar plating. We believe the Acumed Acu-Loc VLP design provided better functional outcomes than the Synthes 2.4 mm LCP if appropriately and carefully placed into its designed-for position. This positioning results in promising patient satisfaction when treating marginal distal radius fractures.
Collapse
|
12
|
Concomitant Acromioclavicular and Coracoclavicular Ligament Reconstruction with a Duo-Figure-8 Autogenic Graft Wrapping Technique for Treating Chronic Acromioclavicular Separation. Clin Orthop Surg 2021; 13:366-375. [PMID: 34484630 PMCID: PMC8380520 DOI: 10.4055/cios20194] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/10/2020] [Accepted: 09/21/2020] [Indexed: 01/21/2023] Open
Abstract
Backgroud Coracoacromial ligament transfer is the traditional procedure for treating chronic acromioclavicular separation, but it is significantly inferior to ligament reconstruction according to biomechanical and clinical studies. However, ligament reconstruction carries the risk of complications of graft loosening and peri-tunnel fractures. Currently, there is no ligament reconstruction procedure optimal for preventing such complications. The purpose of this study was to describe and retrospectively analyze the clinical and radiological outcomes of a “duo-figure-8” autogenic graft wrapping technique, which was used to concomitantly reconstruct the acromioclavicular and coracoclavicular ligaments. Methods Preoperative, immediate postoperative, and final follow-up oputcomes were evaluated in 10 enrolled patients. Radiographic outcomes were indicated by the bilateral difference of the coracoclavicular distance (CCD) and overlapping length of the acromioclavicular joint (OLac). Quality of reduction was classified into 4 grades according to bilateral CCD difference into overreduction (< 0 mm), anatomic reduction (0–4 mm), partial loss of reduction (4–8 mm), and recurrent dislocation (> 8 mm). Clinical outcomes were evaluated using the American Shoulder and Elbow Surgeons (ASES) and Constant scores. Results The mean side-to-side differences for CCD were 11.9 mm (preoperative), −0.1 mm (immediate postoperative), and 3.4 mm (final follow-up); those for OLac were 9.4 mm (preoperative) and 2.7 mm (final follow-up). CCD and OLac outcomes significantly improved at final follow-up (p < 0.05). At the immediate postoperative stage, 6 and 4 patients had overreduction and anatomic reduction, respectively. At final follow-up, 7 and 3 patients had anatomic reduction and partial loss of reduction, respectively. The magnitude of improvement of ASES scores for patients with anatomic reduction and partial loss of reduction (p = 0.20) was 18.1 and 20.0, respectively. The magnitude of improvement of Constant scores in patients with anatomic reduction and partial loss of reduction (p = 0.25) was 19.9 and 22.3, respectively. Conclusions The technique yielded acceptable functional outcomes in patients with anatomic reduction or partial loss of reduction. The “duo-figure-8” wrapping method—a single autogenic tendon graft passing beneath the coracoid process with a tendon-knot fixation over the distal clavicle and looping around the acromion intramedullary—did not increase the risk of peri-tunnel fractures over the clavicle, coracoid process, or acromion.
Collapse
|
13
|
Effect of ammonia and water molecule on OH + CH 3OH reaction under tropospheric condition. Sci Rep 2021; 11:12185. [PMID: 34108500 PMCID: PMC8190139 DOI: 10.1038/s41598-021-90640-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 05/05/2021] [Indexed: 11/21/2022] Open
Abstract
The rate coefficients for OH + CH3OH and OH + CH3OH (+ X) (X = NH3, H2O) reactions were calculated using microcanonical, and canonical variational transition state theory (CVT) between 200 and 400 K based on potential energy surface constructed using CCSD(T)//M06-2X/6-311++G(3df,3pd). The results show that OH + CH3OH is dominated by the hydrogen atoms abstraction from CH3 position in both free and ammonia/water catalyzed ones. This result is in consistent with previous experimental and theoretical studies. The calculated rate coefficient for the OH + CH3OH (8.8 × 10-13 cm3 molecule-1 s-1), for OH + CH3OH (+ NH3) [1.9 × 10-21 cm3 molecule-1 s-1] and for OH + CH3OH (+ H2O) [8.1 × 10-16 cm3 molecule-1 s-1] at 300 K. The rate coefficient is at least 8 order magnitude [for OH + CH3OH(+ NH3) reaction] and 3 orders magnitude [OH + CH3OH (+ H2O)] are smaller than free OH + CH3OH reaction. Our calculations predict that the catalytic effect of single ammonia and water molecule on OH + CH3OH reaction has no effect under tropospheric conditions because the dominated ammonia and water-assisted reaction depends on ammonia and water concentration, respectively. As a result, the total effective reaction rate coefficients are smaller. The current study provides a comprehensive example of how basic and neutral catalysts effect the most important atmospheric prototype alcohol reactions.
Collapse
|
14
|
Abstract
BACKGROUND Plate and locked intramedullary nailing for humeral fractures are golden standard procedure, but the humerus is a nonweight-bearing bone and can tolerate a larger range of acceptable alignment. We believe the elastic stable intramedullary nails (ESINs) can provide enough relative stability for humeral shaft fractures in certain adult patients. METHODS There are four new indications for using ESINs: (1) patient could not tolerate a sugar-tong splint but was a high risk for general anesthesia, (2) intramedullary canal narrowing (<7 mm), (3) long spiral or oblique fracture over the metadiaphyseal junction, and (4) obesity. All patients received retrograde fixation with two titanium elastic nails, except for one patient with a long spiral fracture over the proximal metadiaphysis. Patients had routine follow-up plain radiographs until bone union, and we evaluated functional results of patients by Mayo Elbow Performance Score and asked to complete Quick Disabilities of the Arm, Shoulder and Hand score at the last outpatient clinic visit. RESULTS A total of 16 patients with a mean age of 54.4 years were included. The mean follow-up time was 14 ± 2.5 months, and the average time to bone union was 16 ± 4.3 weeks. There were no wound infections, loss of reduction, fracture nonunion, implant failure, or skin irritation expect for one nail back-out because of osteoporosis. CONCLUSION We have reported good results using ESINs for the displaced fractures of the humerus in the four indication adults who would not be able to tolerate plate fixation or intramedullary nailing. The ESINs fixation method is a simple procedure that provides a small incision, minimal blood loss, short surgical time, and relative stability fixation.
Collapse
|
15
|
A novel low-profile external skeletal fixator for type IIIB open tibial fractures: A biomechanical and clinical pilot study. J Chin Med Assoc 2021; 84:528-535. [PMID: 33595994 DOI: 10.1097/jcma.0000000000000506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Although external fixator is standard for managing staged treatment of open tibial fracture, the main disadvantage of this device is too bulky to be tolerated by most patients for longtime use. The purposes of this pilot study were to compare the biomechanical properties of a novel low-profile external fixator (LP-ESF) with a traditional ESF and also to evaluate its performance in patients with Gustilo type IIIb tibial open fractures. METHODS A prospective clinical pilot study started from January 2015 to December 2017, and 18 patients with Gustilo type IIIb open tibial fractures underwent the fixation with a novel LP-ESF system. The biomechanical properties of the LP-ESF were compared with the Synthes External Fixation System according to the standard ASTM F1541-02. These patients were divided into two groups according to the size of bony defect. The postoperative clinical outcomes were subsequently collected. RESULTS The biomechanical properties of the LP-ESF were comparable with those of Synthes External Fixation System and had an improved the axial/torsional stiffness and ultimate strength. In the clinical study, all patients with LP-ESF had fracture union. The duration of application of LP-ESF was 3.5 to 18 months until fracture union. In 10 of 18 patients, their fractures were immobilized with the LP-ESF until bone union, and no pin tract infection and no chronic osteomyelitis were recorded. The 36-Item Short Form Health Survey life quality and health survey were good to excellent in these patients. Notably, the LP-ESF allowed a patient with severe bone and soft-tissue defects to preserve the leg and joints function. CONCLUSION In this study, we found that the novel LP-ESFs had improved clinical outcomes. The long-term LP-ESF application seems to be tolerable in our patients. This novel approach permits better controls in deep infection and faster healing of fractures, and thus may provide a viable alternative treatment for Gustilo type IIIb open tibial fractures.
Collapse
|
16
|
Peri-implant Fractures Following Hook Plate Fixation for Unstable Distal Clavicle Fractures. Orthopedics 2020; 43:e359-e363. [PMID: 32602920 DOI: 10.3928/01477447-20200619-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Accepted: 05/20/2019] [Indexed: 02/03/2023]
Abstract
Clavicle hook plate is a common implant for treating distal clavicle fracture. Although high bone union rate and good functional outcome have been reported, so have several complications, such as osteolysis and fracture of the acromion, loss reduction, hook impingement, and rotator cuff tear. Peri-implant fracture over the medial side of the hook plate is a rare complication. Sporadic cases have been reported, and most of them have had no history of trauma. Between June 2015 and August 2018, 7 patients treated for distal clavicle fracture with a 3.5-mm locking compression hook plate with no history of trauma experienced peri-implant fracture of the medial clavicle. This complication occurred at a mean of 29 days. The incidence rate was 9.8%. Peri-implant fracture following hook plate fixation for distal clavicle fracture was not rare. Small hook angle, prolonged retention of the implant, an eccentric medial screw, high plate screw density, and small clavicle diameter may be risk factors for peri-implant fracture. Regarding treatment, 2 patients chose fracture revision with a distal clavicle locking plate and 5 patients chose conservative treatment. All patients achieved bone union at fracture sites. Surgical and conservative management of peri-implant fracture can achieve good functional outcome. [Orthopedics. 2020;43(5);e359-e363.].
Collapse
|
17
|
[Practice and Reflection on the Battle against COVID-19 by Guangdong Medical Aid Team in the city of Honghu]. ZHONGHUA YI XUE ZA ZHI 2020; 100:E018. [PMID: 32157848 DOI: 10.3760/cma.j.cn112137-20200228-00496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
|
18
|
A combined prone and supine approaches for complex three column tibial plateau fracture with posterolateral articular injury. Injury 2019; 50:1756-1763. [PMID: 31543317 DOI: 10.1016/j.injury.2019.09.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2019] [Revised: 08/17/2019] [Accepted: 09/06/2019] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Updated three column fixation of tibial plateau fractures (TPFs) arouse the importance of posterior column articular reduction. Complex TPFs with posterolateral (PL) articular injury is difficult to manage. We presented a strategy of combined positions and approaches to treat these injuries. Surgical technique was described and outcome of these were reported. MATERIALS AND METHODS From 2014 Jan to 2016 Dec, there were 132 patients of TPFs treated in our institute. Preoperative evaluation included plain films and 2D/3D CT scan to evaluate the involvement of articular surface and associated columns. Inclusion criteria were three column TPFs with PL corner injury. We put patients in prone position first with reverse L incision to manage PL articular impaction and posteromedial (PM) fractures. Then we repositioned the patients in supine to treat anterolateral fixation. Postoperative radiographic analysis, physical examination findings, and patient reported outcome scores from the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire were recorded. RESULTS Patient demographic information was retrospectively reviewed with a mean follow-up time of 34.4 months (range 24-48 months). The average time to union was 5.2 months (range 4-8months). 13/16 (81%) of patients had satisfactory articular reduction by plain films (less than 2 mm articular step off). All patients demonstrated healed without secondary displacement or infection. All patients demonstrated satisfactory coronal (medial proximal tibia angle 84.68 degrees) and sagittal alignment (posterior proximal tibia angle 84.75 degrees). Condylar width averaged 3.93 mm. 3/16 (19%) of cases required posterolateral columnar plating in addition to posteromedial columnar plating. The knee range of motion averaged 115 degrees (ranged from 0 degrees of extension to140 degrees flexion). The average KOOS score was 83/100 (range 76-90). 3 patients in the series developed a surgical site superficial infection and resolved after debridement and oral antibiotics use. No patient eventually received total knee arthroplasty at the last follow up. CONCLUSIONS Our strategy provides an effective method to treat three column tibial plateau fractures with PL articular injury.
Collapse
|
19
|
Popliteal artery occlusion concomitant with a tibial plateau fracture and posterior cruciate ligament avulsion fracture. J Int Med Res 2019; 48:300060519869073. [PMID: 31510833 PMCID: PMC7593672 DOI: 10.1177/0300060519869073] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
In acute trauma, posterior cruciate ligament (PCL) injury may occur concomitantly with a
bony fracture and be easily overlooked. A popliteal artery injury associated with a tibial
plateau fracture and PCL avulsion fracture is rare. Missed or delayed diagnosis of this
condition leads to a high amputation rate. Therefore, close attention is required with
this type of injury. The limb can be saved though early detection and immediate
reconstruction of the injured artery, followed by fasciotomy. We report here a rare case
of popliteal artery occlusion proximal to the surgical zone, which was diagnosed after
fixation of a medial tibial plateau fracture and posterior cruciate avulsion injury. In
dashboard injuries without knee dislocation, the arterial intima may be injured and become
vulnerable, even with an initial ankle brachial index greater than 0.9. This can cause
concomitant occlusion of the popliteal artery due to iatrogenic retraction during surgery.
Therefore, a neurovascular examination should be repeated to prevent delayed-onset
thrombosis. To the best of our knowledge, this is the first case of popliteal artery
injury concomitant with a tibial plateau fracture and PCL avulsion owing to initial
dashboard injury-related arterial intima injury, which can present with a normal ankle
brachial index.
Collapse
|
20
|
Comparison of Wide-Awake Local Anesthesia No Tourniquet With General Anesthesia With Tourniquet for Volar Plating of Distal Radius Fracture. Orthopedics 2019; 42:e93-e98. [PMID: 30540881 DOI: 10.3928/01477447-20181206-01] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Accepted: 07/18/2018] [Indexed: 02/03/2023]
Abstract
Wide-awake local anesthesia no tourniquet (WALANT) is used for various hand surgeries, but there are no reports of its use for distal radius fractures. The authors compared perioperative variables and clinical outcomes for volar plating for distal radius fractures with WALANT vs general anesthesia with tourniquet. This retrospective study included 47 patients who presented with distal radius fractures between January 2015 and February 2017. Twenty-one underwent surgical volar plating with WALANT, and 26 underwent surgical volar plating with general anesthesia with tourniquet. Patients were followed for 12 months. The 2 groups were compared regarding perioperative parameters and clinical outcomes, including perioperative field pain evaluated by visual analog scale score on postoperative day 1, range of motion 12 months postoperatively, and Mayo wrist score. The WALANT group had a lower mean visual analog scale score and a shorter mean hospitalization (both P<.001), but greater mean blood loss (P<.001). No significant differences were found regarding operative time (P=.214) or time to union (P=.180). At 12-month follow-up, no significant differences were found regarding wrist extension (P=.721), wrist flexion (P=.119), or Mayo wrist score (P=.223). Although both techniques permitted volar plating for distal radius fractures, WALANT allowed immediate intervention and led to less postoperative pain and shorter hospitalization. Although control of blood loss was worse with WALANT, blood loss was limited to a mean of 22.62 mL and did not interfere with the surgical field. [Orthopedics. 2019; 42(1):e93-e98.].
Collapse
|
21
|
WALANT for distal radius fracture: open reduction with plating fixation via wide-awake local anesthesia with no tourniquet. J Orthop Surg Res 2018; 13:195. [PMID: 30081923 PMCID: PMC6091186 DOI: 10.1186/s13018-018-0903-1] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Accepted: 07/30/2018] [Indexed: 11/29/2022] Open
Abstract
Background The wide-awake local anesthesia no tourniquet (WALANT) technique is applied during various hand surgeries. We investigated the perioperative variables and clinical outcomes of open reduction and internal fixation (ORIF) for distal radius fractures under WALANT. Methods From January 2015 to January 2017, 60 patients with distal radius fractures were treated, and 24 patients (40% of all) were treated with either a volar or a dorsal plate via WALANT procedure. Of these 24 patients, 21 radius fractures were fixed with a volar plate, and the other 3 were fixed with a dorsal plate. Radiographs; range of motions; visual analog scale (VAS); quick disabilities of the arm, shoulder, and hand (Quick DASH) questionnaire; and time to union were evaluated. Results One of the 24 patients could not tolerate the WALANT procedure and was reported as a failed attempt at WALANT. In the cohort, 23 patients successfully received distal radius ORIF under WALANT procedure. The average age is 60.9 (range, 20–88) years. The average operation time was 64.3 (range, 45–85) minutes, the average blood loss was 18.9 (range, 5–30) ml, and the average of duration of hospitalization is 1.8 (range, 1–6) days. The average postoperative day one VAS was 1.6 (range, 1–3). The average time of union was 20.7 (range, 15–32) weeks. The mean follow-up period was 15.1 (range, 12–24) months. Functional 1-year postoperative outcomes revealed an average Quick DASH score of 7.60 (range, 4.5–13.6) and an average wrist flexion and extension of 69.6° (range, 55–80°) and 57.4° (range, 45–70°). There was no wound infection, neurovascular injury, or other major complication noted. Conclusions WALANT for distal radius fracture ORIF is a method to control blood loss by the effects of local anesthesia mixed with hemostatic agents. Without a tourniquet, the procedure prevents discomfort caused by tourniquet pain. Without sedation, patients could perform the active range of motion of the injured wrist to check if there is impingement of implants. It eliminates the need of numerous preoperative examinations, postoperative anesthesia recovery room care, and side effects of the sedation. However, patients who are not amenable to the awake procedure are contraindications. Electronic supplementary material The online version of this article (10.1186/s13018-018-0903-1) contains supplementary material, which is available to authorized users.
Collapse
|
22
|
Single coracoclavicular suture fixation with Mersilene tape versus hook plate in the treatment of acute type V acromioclavicular dislocation: a retrospective analysis. J Orthop Surg Res 2018; 13:110. [PMID: 29769141 PMCID: PMC5956760 DOI: 10.1186/s13018-018-0831-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2017] [Accepted: 05/08/2018] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND Here, we compared the clinical and radiographic outcomes between coracoclavicular (CC) fixation with Mersilene tape and hook plate for acute unstable acromioclavicular (AC) joint dislocation treatment. METHODS We enrolled 49 patients with unstable acute AC dislocation who, between January 2010 and January 2014, underwent surgery with single CC suture fixation with Mersilene tape (M group, 25 cases) or clavicle hook plate (H group, 24 cases). In M and H groups, the average age was 43.7 (range 18-72) and 42.0 (range 17-84) years, the male to female ratio of each group was 15:20 and 19:5, and the injured side left to right ratio was 12:13 and 11:13, respectively. All patients were right-handed. We retrospectively compared the operation time, complication rate, visual analog scale (VAS), University of California at Los Angeles (UCLA) shoulder rating scale, Oxford shoulder scores, and the radiographic outcomes based on reduction loss of CC distance on postoperative follow-up. RESULTS No significant difference in patient demographics between the two groups in age (p = 0.709), gender (p = 0.217), time from injury to surgery (p = 0.863), and injured side (p = 1.000). The mean follow-up was 26.2 months (range 24-35 months). Nine cases of reduction loss (36%) and one of distal clavicle osteolysis (4%) were noted in the M group. CC distance improvement in the H group was significantly superior to that in the M group at 3 months (before hook plate removal, p < 0.001) and 12 months postoperatively (after hook plate removal, p = 0.004), while subacromial erosions were revealed in nine cases (37.5%) in the H group. No significant difference in operative time (p = 0.846), complication rate (p = 1.000), VAS (p = 0.199), mean UCLA shoulder rating scale (p = 0.353), and Oxford shoulder (p = 0.224) scores between the two groups. CONCLUSIONS Both hook plate and Mersilene tape fixations provided temporary stabilization of acute type V AC dislocation and yielded comparable clinical outcomes. The hook plate provided better maintenance of reduction of radiographic outcomes. CC suture fixation with Mersilene tape may serve as an alternative method of stabilization which provides acceptable outcome without the need of implant removal.
Collapse
|
23
|
Comparing morbidities of bone graft harvesting from the anterior iliac crest and proximal tibia: a retrospective study. J Orthop Surg Res 2018; 13:115. [PMID: 29769090 PMCID: PMC5956943 DOI: 10.1186/s13018-018-0820-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Accepted: 04/26/2018] [Indexed: 01/17/2023] Open
Abstract
Background The anterior iliac crest (AIC) and proximal tibia (PT) are common donor sites for autologous bone graft harvesting. We compared pain levels at these harvest sites on 1 day, 5 days, 2 weeks, 4 weeks, and 8 weeks post-harvest. Methods We retrospectively reviewed 18 patients undergoing autologous bone grafting surgery at a level I trauma center between June 2013 and October 2014. Ten grafts were harvested from the AIC group and eight from the PT group. A standard visual analog scale (VAS) was used to rate pain at the harvest sites on postoperative day (POD) 1, 5, 14, 28, and 56 and at the recipient site on POD 1. Results There were no statistically significant differences between both groups in age (p = 0.474), gender (p = 1.00), incidence of harvest site morbidity (p = 1.00), and average VAS at the recipient site on POD 1 (p = 0.471). VAS at the harvest site on POD 1, 5, and 14 confirmed statistically that pain was more severe in the AIC group than in the PT group (p < 0.001). However, no significant difference was observed on POD 28 and 56 between both groups. Pain was significantly less on POD 1 in the PT group at the harvest site than at the recipient site (p < 0.001). Conclusions The PT is a suitable harvest site, producing statistically less pain for at least two postoperative weeks than the AIC. Besides, patients report less postoperative pain at the PT harvest site than at the recipient site.
Collapse
|
24
|
Letter to the Editor. Tranexamic acid for reducing intra- and postoperative blood loss in posterior lumbar interbody fusion: Is it safe enough? J Neurosurg Spine 2018; 29:226-227. [PMID: 29701567 DOI: 10.3171/2017.11.spine171178] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
25
|
Oligonucleotide-Based Fluorescent Probe for Sensing of Cyclic Diadenylate Monophosphate in Bacteria and Diadenosine Polyphosphates in Human Tears. ACS Sens 2016. [DOI: 10.1021/acssensors.6b00425] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
26
|
The Impacts of Contact Etch Stop Layer Thickness and Gate Height on Channel Stress in Strained N-Metal Oxide Semiconductor Field Effect Transistors. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY 2015; 15:2673-2679. [PMID: 26353480 DOI: 10.1166/jnn.2015.9834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The stress induced by strain in the channel of metal oxide semiconductor field effect transistors (MOSFET) is an effective method to boost the device performance. The geometric dimensions of spacer, gate height, and the contact etch stop layer (CESL) are important factors among the feasible booster. This study utilized the mismatch of the thermal expansion coefficients of stressors to simulate the process-induced stress in the N-MOSFET. Different temperatures are applied to different region of the device to generate the required strain. The analysis was performed by well-developed finite element package. The composite spacers with variant width of inserted silicon nitride (SiO2/SiN/SiO2, ONO) were proposed and their impacts on channel stress were compared. Two aspects of the impacts of those factors on the channel stress in the longitudinal direction for N-MOSFET with variant channel length were investigated. Firstly, the channel stresses of device without CESL for different gate heights were studied. Secondly, with stress applied to CESL and ONO spacers, the induced stresses in the channel were analyzed for long/short gate length. Two conclusions were drawn from the results of simulation. The N-MOSFET device without CESL shows that the stressed spacer alone generates compressive stress and the magnitude increases along with higher gate height. The channel stress becomes tensile for device with CESL and increases when the thickness of CESL and the height of gate increase, especially for device with shorter gate length. The gate height plays more significant role in inducing channel stress compared with the thickness of CESL. The channel stress can be used to quantify the mobility of electron/hole for strained MOSFET device. Therefore, with the guideline disclosed in this study, better device performance can be expected for N-MOSFET.
Collapse
|
27
|
Single uroflow study as a tool in predicting the possibility of abnormal voiding symptoms after the administration of antimuscarinic agents in treating overactive bladder syndrome. CLIN EXP OBSTET GYN 2015; 42:152-155. [PMID: 26054108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
PURPOSE OF STUDY The aim of this study was to evaluate the efficacy of uroflowmetry in predicting the possibility of abnormal voiding symptoms following antimuscarinic treatment for overactive bladder syndrome (OAB) in Taiwanese women. MATERIALS AND METHODS A retrospective study was conducted on women with OAB. Forty-five women with abnormal voiding patterns shown by urodynamic study comprised the main group and 38 women with normal voiding patterns comprised the control group. All patients were prescribed two mg tolterodine once daily for one week. Follow-up on complaints of abnormal voiding symptoms was done one week later. RESULTS One woman in control group and 12 women in main group complained of abnormal voiding symptoms. There was a significant difference in the occurrence of abnormal voiding symptoms after antimuscarinic administration between main study group and control group (26.7 % vs 2.6 %, p = 0.02). CONCLUSIOn: Uroflowmetry is a non-invasive and simple tool to predict the occurrence of abnormal voiding symptoms after antimuscarinic use.
Collapse
|
28
|
Removal of forearm plate leads to a high risk of refracture: decision regarding implant removal after fixation of the forearm and analysis of risk factors of refracture. Arch Orthop Trauma Surg 2014; 134:1691-7. [PMID: 25168787 DOI: 10.1007/s00402-014-2079-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2014] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Plate fixation is the gold standard for the treatment of forearm fractures at present, and whether or not to remove the implant after bone union remains controversial. This study demonstrated some cases of refracture in adult forearm fractures after bone union and discussed the risk factors for decision-making regarding implant removal. METHODS We reviewed patients with forearm diaphyseal fractures (including the radius, ulna, or both bones) who received open reduction and internal fixation (ORIF) from January 2008 to May 2011 in our institute. Fracture type was classified according to the AO/OTA system. All patients were fixed with a 3.5-mm dynamic compression plate. The patients were divided into two main groups: group A received implant removal after bone union, and group B retained the implant. RESULTS There were 122 patients (170 bones) included in this study (40 females and 82 males). In group A, 7/51 patients (8/62 bones; 12.9 %) had refracture. As classified by the AO/OTA classification, one patient was classified as type A1, one patient as type A2, two patients as type A3, and three patients as type B3. All patients suffered refracture without high-energy trauma. In group B, the refracture rate was 2.77 %, and all were caused by high-energy trauma. Patients with refracture had a shorter time interval between ORIF and implant removal. The possible risk factors of refracture in this study included a wedge bone defect on plain film, implant removal performed after less than 18 months, and AO/OTA type B fracture. CONCLUSION The incidence of refracture was significantly lower in the group that retained the implant. Routine implant removal after bone union in adult forearm fractures is not recommended due to the higher refracture rate.
Collapse
|
29
|
Comparison of outcome of unilateral locking plate and dual plating in the treatment of bicondylar tibial plateau fractures. J Orthop Surg Res 2014; 9:62. [PMID: 25038620 PMCID: PMC4223614 DOI: 10.1186/s13018-014-0062-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2013] [Accepted: 07/01/2014] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Tibial plateau fracture (TPF) includes different fracture patterns with varied degrees of articular depression and displacement. Many kinds of fixators, including newly designed plate with locking screws, were applied to treat these complicated fractures. We intended to follow up the surgical outcomes of (1) unilateral locking plate, (2) classic dual plates, or (3) hybrid dual plates for TPF. MATERIALS AND METHODS We retrospectively reviewed 76 patients with TPF, Schatzker types V and VI, who we operated from June 2006 to May 2009 in our institute. Excluding patients who expired due to other medical conditions and without complete follow-up, 45 patients were sorted out in this series. The scheme of surgical intervention was designed by visiting staff, and 15 patients, as group I, were treated with unilateral locking plate. The other 19 patients, as group II, were treated with classic dual plates. The residual 11 patients, as group III, were treated with hybrid dual plates (one lateral approach locking compression plate (LCP) + medial anti-gliding plate). All patients were under periodic F/U at about 6 weeks interval for at least 18 months postoperatively. RESULTS In group I, 13 cases achieved solid bony union without obvious traumatic OA change, limitation of ROM, or malalignment. In groups II and III, 15 and 10 patients reached the same goal, respectively. By analysis of the recorded parameters with statistical software (SPSS 12.0), there were five parameters with significant difference, including Schatzker classification, operation time, staged treatment or not, hospitalization period, and hardware impingement. CONCLUSIONS There was no significant statistical difference of union rate between these three groups in our series. Based on our clinical follow-up, several key points were emphasized: (1) Soft tissue problems should be kept in mind, and usage of locking plate can reduce the discomfort of hardware impingement effectively. (2) The single lateral approach technique for TPF with locking plate results in less operation time and shorter hospitalization period. (3) If the medial buttress cannot be established by reduction of the lateral fracture, then open reduction of the medial side is necessary and buttresses the medial fragment by dual plates.
Collapse
|
30
|
Reply: To PMID 24762147. Orthopedics 2014; 37:364-5. [PMID: 25110775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
31
|
Comparison of single coracoclavicular suture fixation and hook plate for the treatment of acute unstable distal clavicle fractures. J Orthop Surg Res 2014; 9:42. [PMID: 24885387 PMCID: PMC4049442 DOI: 10.1186/1749-799x-9-42] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2013] [Accepted: 05/06/2014] [Indexed: 12/01/2022] Open
Abstract
Background Surgical managements are recommended for unstable distal clavicle fractures because of a high incidence of nonunion. A variety of methods have been previously reported, but there is no current consensus regarding which method is the most suitable. Methods Between December 2004 and August 2010, we treated 68 patients with Neer type IIB distal clavicle fractures using single coracoclavicular suture fixation with Mersilene tape (M group) or clavicular hook plate (H group). Sixty-eight patients were followed at least 24 months (mean, 37.9 months). We retrospectively compared the functional outcome, parameters, and perioperative course of the two treatments. Statistical analysis was performed with independent sample t test and chi-square test. Results The M group presented significantly less operation time (P = 0.005) and intra-operative blood loss (P = 0.010) than the H group. The mean University of California at Los Angeles (UCLA) shoulder rating scale, Oxford shoulder score, VAS scale, and satisfaction score revealed no significant difference between the M group and the H group. The M group had better range of motion in the operated shoulder during forward flexion and abduction at 3 and 6 months postoperatively. However, the range of motion at 1 and 2 years after operation revealed almost the same results. Two acromial osteolysis and one acromial fracture were noted in the H group and one superficial wound infection and one frozen shoulder in the M group during follow-up. Finally, there was no significant difference in the complication rate between the two groups, and all fractures achieved union clinically at final follow-up. Conclusions Both single coracoclavicular suture fixation and clavicular hook plate offered effective treatment in acute unstable distal clavicle fractures. However, single coracoclavicular suture fixation with Mersilene tape provided early recovery of shoulder motion and avoided further morbidity of the acromion.
Collapse
|
32
|
Influence of nail prominence and insertion point on anterior knee pain after tibial intramedullary nailing. Orthopedics 2014; 37:e221-5. [PMID: 24762147 DOI: 10.3928/01477447-20140225-52] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Accepted: 11/25/2013] [Indexed: 02/03/2023]
Abstract
Chronic anterior knee pain is the most common complication after tibial nail insertion. Its etiology remains unknown, and multifactorial sources have been suggested. The authors believe that nail prominence and the insertion point of the nail are important in the development of anterior knee pain. The purpose of this retrospective study was to evaluate the roles of the insertion point and nail prominence in anterior knee pain after tibial intramedullary nailing using a transtendinous approach and a common nail type. A total of 108 patients with tibial shaft fractures underwent reamed intramedullary nailing using a transtendinous approach between 2006 and 2009. Mean follow-up was 26.8±5.0 months. A visual analog scale (0-100) was used to estimate anterior knee pain severity while patients performed 7 activities retrospectively. Radiographic assessments, including nail prominence and insertion point, were performed. Sixty (55.6%) patients experienced knee pain (group P) and 48 (44.4%) did not (group N). Significant differences were not found between the groups with respect to demographics, nail diameters, or fracture classifications. Less superior and more anterior nail prominences in radiographic assessments were significantly associated with anterior knee pain. When the insertion point was over the bottom half of the anterior cortex, the influence of anterior nail prominence was more obvious. Nail removal resulted in diminished pain during the 7 assessed activities. Nail insertion should be over the bottom half of the anterior cortex, with minimal anterior nail prominence. If anterior knee pain occurs, removal of the nail should be considered.
Collapse
|
33
|
Abstract
Molecular beacon-based NAND logic gate was simple, rapid, selective, and sensitive for probing triplex DNA binders.
Collapse
|
34
|
Revealing biogenic sulfuric acid corrosion in sludge digesters: detection of sulfur-oxidizing bacteria within full-scale digesters. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2014; 70:1405-1411. [PMID: 25353947 DOI: 10.2166/wst.2014.371] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Biogenic sulfuric acid corrosion (BSA) is a costly problem affecting both sewerage infrastructure and sludge handling facilities such as digesters. The aim of this study was to verify BSA in full-scale digesters by identifying the microorganisms involved in the concrete corrosion process, that is, sulfate-reducing (SRB) and sulfur-oxidizing bacteria (SOB). To investigate the SRB and SOB communities, digester sludge and biofilm samples were collected. SRB diversity within digester sludge was studied by applying polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE) targeting the dsrB-gene (dissimilatory sulfite reductase beta subunit). To reveal SOB diversity, cultivation dependent and independent techniques were applied. The SRB diversity studies revealed different uncultured SRB, confirming SRB activity and H2S production. Comparable DGGE profiles were obtained from the different sludges, demonstrating the presence of similar SRB species. By cultivation, three pure SOB strains from the digester headspace were obtained including Acidithiobacillus thiooxidans, Thiomonas intermedia and Thiomonas perometabolis. These organisms were also detected with PCR-DGGE in addition to two new SOB: Thiobacillus thioparus and Paracoccus solventivorans. The SRB and SOB responsible for BSA were identified within five different digesters, demonstrating that BSA is a problem occurring not only in sewer systems but also in sludge digesters. In addition, the presence of different SOB species was successfully associated with the progression of microbial corrosion.
Collapse
|
35
|
Detection of posterior pelvic injuries in fractures of the pubic rami but only posterior fixation is not always enough. Injury 2013; 44:1655. [PMID: 23245871 DOI: 10.1016/j.injury.2012.10.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Accepted: 10/21/2012] [Indexed: 02/02/2023]
|
36
|
A simple technique of suture loop for acute acromioclavicular joint dislocation. Injury 2013; 44:1662-3. [PMID: 23642626 DOI: 10.1016/j.injury.2013.03.036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2013] [Accepted: 03/31/2013] [Indexed: 02/02/2023]
|
37
|
Intensification of a chemical burn injury by a warming device combined with the tissue pressure in the operating room. A & A CASE REPORTS 2013; 1:9-11. [PMID: 25611603 DOI: 10.1097/acc.0b013e31828d6c6f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A 19-year-old girl suffered an unexpected gasoline-associated chemical burn injury that may have been intensified by a warming device and tissue pressure in the operating room. Anesthesiologists should be aware that serious skin injury may result from combination of cutaneous exposure to hydrocarbons, especially when warming devices are simultaneously used.
Collapse
|
38
|
Decoherence cross-section in NO + Ar collisions: experimental results and a simple model. J Phys Chem A 2013; 117:8119-25. [PMID: 23556513 DOI: 10.1021/jp401005v] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Quantum decoherence can be viewed as the mechanism responsible for the quantum-to-classical transition as the initially prepared quantum state interacts with its environment in an irreversible manner. One of the most common mechanisms responsible for the macroscopically observed decoherence involves collisions of an atom or molecule, initially prepared in a coherent superposition of states, with gas particles. In this work, a coherent superposition of quantum internal states of NO molecules is prepared by the interaction between the molecule with both a static and a radiofrequency electric field. Subsequently, NO + Ar collision decoherence experiments are investigated by measuring the loss of coherence as a function of the number of collisions. Data analysis using a model based on the interaction potential of the collisional partners allowed to unravel the molecular mechanism responsible for the loss of coherence in the prepared NO quantum superposition of internal states. The relevance of the present work relies on several aspects. On the one hand, the use of radio-waves introduces a new way for the production of coherent beams. On the other hand, the employed methodology could be useful in investigating the Stereodynamics of chemical reactions with coherent reagents.
Collapse
|
39
|
On-line sample preconcentration by sweeping and poly(ethylene oxide)-mediated stacking for simultaneous analysis of nine pairs of amino acid enantiomers in capillary electrophoresis. Talanta 2013; 114:297-303. [PMID: 23953474 DOI: 10.1016/j.talanta.2013.05.039] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2013] [Revised: 05/15/2013] [Accepted: 05/16/2013] [Indexed: 12/31/2022]
Abstract
This study proposes a sensitive method for the simultaneous separation and concentration of 9 pairs of amino acid enantiomers by combining poly(ethylene oxide) (PEO)-based stacking, β-cyclodextrin (β-CD)-mediated micellar electrokinetic chromatography (MEKC), and 9-fluoroenylmethyl chloroformate (FMOC) derivatization. The 9 pairs of FMOC-derivatized amino acid enantiomers were baseline separated using a discontinuous system, and the buffer vials contained a solution of 150 mM Tris-borate (TB), 12.5% (v/v) isopropanol (IPA), 0.5% (w/v) PEO, 35 mM sodium taurodeoxycholate (STDC), and 35 mM β-CD, and the capillary was filled with a solution of 1.5 M TB, 12.5% (v/v) IPA, 35 mM STDC, and 35 mM β-CD. Based on the difference in viscosity between the sample zone and PEO solution and because of the STDC sweeping, the discontinuous system effectively stacked 670 nL of the 9 pairs of FMOC-derivatized amino acid enantiomers without losing chiral resolution. Consequently, the limits of detection for the 9 pairs of FMOC-derivatized amino acid enantiomers were reduced to 40-60 nM. This method was successfully used to determine d-Tryptophan (Trp), l-Trp, d-Phenylalanine (Phe), l-Phe, d-Glutamic acid (Glu), and l-Glu in various types of beers.
Collapse
|
40
|
Gender difference of childhood overweight and obesity in predicting the risk of incident asthma: a systematic review and meta-analysis. Obes Rev 2013; 14:222-31. [PMID: 23145849 DOI: 10.1111/j.1467-789x.2012.01055.x] [Citation(s) in RCA: 148] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Revised: 08/29/2012] [Accepted: 09/23/2012] [Indexed: 11/28/2022]
Abstract
The aims of our meta-analysis were (i) to quantify the predictability of childhood overweight and obesity on the risk of incident asthma; and (ii) to evaluate the gender difference on this relationship. The selection criteria included prospective cohort paediatric studies which use age- and sex-specific body mass index (BMI) as a measure of childhood overweight and the primary outcome of incident asthma. A total of 1,027 studies were initially identified through online database searches, and finally 6 studies met the inclusion criteria. The combined result of reported relative risk from the 6 included studies revealed that overweight children conferred increased risks of incident asthma as compared with non-overweight children (relative risk, 1.19; 95% confidence interval [CI], 1.03-1.37). The relationship was further elevated for obesity vs. non-obesity (relative risk, 2.02; 95% CI, 1.16-3.50). A dose-responsiveness of elevated BMI on asthma incidence was observed (P for trend, 0.004). Obese boys had a significantly larger effect than obese girls (relative risk, boys: 2.47; 95% CI, 1.57-3.87; girls: 1.25; 95% CI, 0.51-3.03), with significant dose-dependent effect. Proposed mechanisms of gender difference could be through pulmonary mechanics, sleep disordered breathing and leptin. Further research might be needed to better understand the exact mechanism of gender difference on the obesity-asthma relationship.
Collapse
|
41
|
Comparative study of the proximal femoral nail antirotation versus the reconstruction nail in the treatment of comminuted proximal femoral fracture. Orthopedics 2012; 35:e41-7. [PMID: 22229612 DOI: 10.3928/01477447-20111122-02] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The purpose of our study was to compare the proximal femoral nail antirotation (PFNA; Synthes, Paoli, Pennsylvania) with a reconstruction nail (Recon; Zimmer, Warsaw, Indiana) in the treatment of comminuted proximal femoral fractures. Between 2003 and 2010, twenty-three consecutive patients with AO/Orthopaedic Trauma Association 31-A3 fractures combined with proximal 32 fractures who had a minimum 18-month follow-up were evaluated retrospectively. There were 10 patients (age range, 18-74 years) in the Recon nail group and 13 patients (age range, 22-90 years) in the PFNA nail group. Patients treated with Recon nails experienced a longer operation time (P=.006) and more blood loss (P=.012) than patients treated with the PFNA nail. On postoperative radiographs, the change in the neck-shaft angle was 8.8° in the Recon nail group and 4.7° in the PFNA nail group (P=.048). The fracture union time averaged 31.8 weeks in the Recon nail group and 21.5 weeks in the PFNA nail group (P=.148). More patients in the Recon nail group underwent major or minor reoperation (P=.038) compared with the PFNA nail group. No implant failure occurred in either group. The functional results were similar in the 2 groups. For the treatment of comminuted proximal femoral fractures, use of either the PFNA and Recon nail is clinically effective. However, the PFNA nail provides a shorter operation time, less blood loss, and better realignment ability and reduces the incidence of reoperation. Therefore, the PFNA nail can be considered a better device than the Recon nail.
Collapse
|
42
|
Combination of baclofen and antimuscarinics to reduce voiding difficulty in treating women with overactive bladders. CLIN EXP OBSTET GYN 2012; 39:171-174. [PMID: 22905457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
PURPOSE OF STUDY To evaluate the efficacy of baclofen in combination with antimuscarinics to treat women with an overactive bladder (OAB) with abnormal voiding patterns. METHODS An action research and chart review was conducted in 245 OAB women. Women were prescribed tolterodine or oxybutynin with or without baclofen after urodynamics. The complaint of voiding difficulty was followed up one week later. RESULTS There was a significant difference in the occurrence of voiding difficulty after antimuscarinic administration in OAB women with abnormal voiding patterns compared with normal patterns (18% vs 4.9%, respectively; p = 0.013). The clinical difference of voiding difficulty after treating with antimuscarinics between both voiding patterns disappeared after adding baclofen (abnormal voiding pattern vs normal pattern; 11.1% vs. 5.6%, respectively; p = 1.000). CONCLUSION Combined use of baclofen and antimuscarinic agents could reduce voiding difficulty in treating women with overactive bladders with abnormal voiding patterns.
Collapse
|
43
|
Effects of spiked metals on the MSW anaerobic digestion. WASTE MANAGEMENT & RESEARCH : THE JOURNAL OF THE INTERNATIONAL SOLID WASTES AND PUBLIC CLEANSING ASSOCIATION, ISWA 2012; 30:32-48. [PMID: 20880938 DOI: 10.1177/0734242x10383079] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
This study aimed to investigate the effects of eight metals on the anaerobic digestion of the organic fraction of municipal solid waste (OFMSW) in bioreactors. Anaerobic bioreactors containing 200 mL MSW mixed completely with 200 m L sludge seeding. Ca and K (0, 1000, 2000 and 6,000 mg L(-1)) and Cr, Ni, Zn, Co, Mo and W (0, 5, 50 and 100 mg L(-1)) of various dose were added to anaerobic bioreactors to examine their anaerobic digestion performance. Results showed that except K and Zn, Ca (~728 to ~1,461 mg L(-1)), Cr (~0.0022 to ~0.0212 mg L(-1)), Ni (~0.801 to ~5.362 mg L(-1)), Co (~0.148 to ~0.580 mg L(-1)), Mo (~0.044 to ~52.94 mg L(-1)) and W (~0.658 to ~40.39 mg L(-1)) had the potential to enhance the biogas production. On the other hand, except Mo and W, inhibitory concentrations IC(50) of Ca, K, Cr, Ni, Zn and Co were found to be ~3252, ~2097, ~0.124, ~7.239, ~0.482, ~8.625 mg L(-1), respectively. Eight spiked metals showed that they were adsorbed by MSW to a different extent resulting in different liquid metals levels and potential stimulation and inhibition on MSW anaerobic digestion. These results were discussed and compared to results from literature.
Collapse
|
44
|
Epizootic myocarditis associated with encephalomyocarditis virus in a group of rhesus macaques (Macaca mulatta). Vet Pathol 2011; 49:386-92. [PMID: 21653204 DOI: 10.1177/0300985811409254] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Six cases of fatal myocarditis associated with encephalomyocarditis virus occurred over a 14-month period in a group of outdoor-housed juvenile rhesus macaques. All animals were younger than 3 years of age and died or were euthanized following acute onset of dyspnea or pulmonary effusion (3 of 6) or were found dead without premonitory signs (3 of 6). Gross findings included pulmonary congestion (6 of 6), variable degrees of pleural effusion (4 of 6), multifocal pale tan foci throughout the myocardium (3 of 6), hepatomegaly and hepatic congestion (3 of 6), and pericardial effusion (1 of 6). Histologically, affected myocardium was infiltrated multifocally by lymphoplasmacytic and histiocytic inflammation admixed with necrotic and degenerate myofibers and infrequent mineralization (6 of 6). Pulmonary edema was present in all animals. Encephalomyocarditis virus was confirmed in 6 of 6 hearts by immunohistochemistry, and virus was isolated from one case by polymerase chain reaction. Sequencing of virus isolated from 1 affected animal indicated infection with a novel encephalomyocarditis virus. Encephalomyocarditis virus should be considered as a differential etiology in outbreaks of myocarditis and pulmonary edema in juvenile primates.
Collapse
|
45
|
Stacking and separation of aspartic acid enantiomers under discontinuous system by capillary electrophoresis with light-emitting diode-induced fluorescence detection. Talanta 2010; 82:1912-8. [DOI: 10.1016/j.talanta.2010.08.009] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2010] [Revised: 08/06/2010] [Accepted: 08/09/2010] [Indexed: 10/19/2022]
|
46
|
Modeling biogas production from organic fraction of MSW co-digested with MSWI ashes in anaerobic bioreactors. BIORESOURCE TECHNOLOGY 2010; 101:6329-6335. [PMID: 20400299 DOI: 10.1016/j.biortech.2010.03.048] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2010] [Revised: 03/08/2010] [Accepted: 03/11/2010] [Indexed: 05/29/2023]
Abstract
This study aims at investigating the effects of MSW incinerator fly ash (FA) and bottom ash (BA) on the anaerobic co-digestion of OFMSW with FA or BA. It also simulates the biogas production from various dosed and control bioreactors. Results showed that suitable ashes addition (FA/MSW 10 and 20 g L(-1) and BA/MSW 100 g L(-1)) could improve the MSW anaerobic digestion and enhance the biogas production rates. FA/MSW 20 g L(-1) bioreactor had the higher biogas production and rate implying the potential option for MSW anaerobic co-digestion. Modeling studies showed that exponential plot simulated better for FA/MSW 10 g L(-1) and control bioreactors while Gaussian plot was applicable for FA/MSW 20 g L(-1) one. Linear and exponential plot of descending limb both simulated better for BA/MSW 100 g L(-1) bioreactor. Modified Gompertz plot showed higher correlation of biogas accumulation than exponential rise to maximum plot for all bioreactors.
Collapse
|
47
|
Abstract
Small intestinal adenocarcinomas are uncommon neoplasms that are rarely reported in nonhuman primates. These neoplasms are also rare in humans, although they are thought to share a similar pathogenesis with the more common colorectal carcinoma. Herein the authors report the clinical, histologic, immunohistochemical, and molecular characteristics of small intestinal adenocarcinoma in 10 common marmosets (Callithrix jacchus). Retrospective analysis of necropsy records revealed small intestinal carcinoma to be the most common neoplastic cause of morbidity and mortality in aged common marmosets. The average age of affected animals was 6.6 years old, and there was no sex predilection. Nine of 10 (90%) tumors arose within the proximal small intestine near the interface with the duodenum. All cases were characterized by disorganization, loss of polarity, and proliferation of neoplastic epithelial cells along the crypt to midvillous interface. Two of 10 (20%) were defined as carcinoma in situ. Eight of 10 (80%) had some degree of invasion, with lymphatic invasion and lymph node metastasis present in 6 of 10 (60%) animals. Immunohistochemically, 10 of 10 (100%) expressed cytokeratin; 7 of 9 (77%) expressed E-cadherin; and 8 of 9 (88%) expressed beta-catenin. The expression of E-cadherin and beta-catenin was decreased in the cell membrane and increased in the cytoplasm. No Helicobacter-like bacteria were observed via silver stain, and callitrichine herpesvirus 3 was detected by polymerase chain reaction with equal frequency from neoplastic and nonneoplastic intestinal sections. The tumors described in this population illustrate comparable features to human cases of small intestine carcinoma and may serve as a potential animal model for small intestinal carcinomas.
Collapse
|
48
|
Nanocontact resistance and structural disorder induced resistivity variation in metallic metal-oxide nanowires. NANOTECHNOLOGY 2009; 20:455401. [PMID: 19822926 DOI: 10.1088/0957-4484/20/45/455401] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Several systems of metallic metal-oxide nanowires (NWs), including pure RuO2 and as-implanted and annealed Ru(0.98)Cu(0.02)O2 and Ru(0.93)Cu(0.07)O2 NWs, have been employed in two-probe electrical characterizations by using a transmission electron microscope-scanning tunneling microscope technique with a gold tip. Thermal, mechanical, and electron beam exposing treatments are consecutively applied to reduce the electrical contact resistance, generated from the interface between the NW and the gold tip, so as to evaluate the intrinsic NW resistance. It is found that the residual contact resistance cannot be entirely removed. For each system of metallic metal-oxide NWs, several tens of NWs are applied to electrical characterizations and the total resistances unveil a linear dependence on the ratio of the length to the area of the NWs. As a result, the average resistivity and the contact resistance of the metallic metal-oxide NWs could be evaluated at room temperatures. The average resistivities of pure RuO2 NWs agree well with the results obtained from standard two- and four-probe electrical-transport measurements. In addition, the as-implanted Cu-RuO2 NWs reveal disordered crystalline structures in high-resolution TEM images and give higher resistivities in comparison with that of pure RuO2 NWs. The residual contact resistances of all kinds of metallic metal-oxide NWs unveil, more surprisingly, an approximation value of several kilohms, even though the average resistivities of these NWs change by more than one order of magnitude. It is argued that the ductile gold tip makes one or more soft contacts on the stiff metal-oxide NWs with nanometer roughness and the nanocontacts on the NWs contribute to the electrical contact resistance.
Collapse
|
49
|
Fluorescence signals of quantum dots influenced by spatially controlled array structures. NANOTECHNOLOGY 2009; 20:415201. [PMID: 19755732 DOI: 10.1088/0957-4484/20/41/415201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Fluorescence signals of quantum dots (QDs) influenced by different array structures of gold-coated silicon nanorods (SiNRs) were investigated via experimental observations and two-dimensional (2D) finite element method (FEM) simulations. On the densest gold-coated SiNRs array structure, the highest QD fluorescence quenching rates were observed and on the sparsest array structure, the highest QD fluorescence enhancement rates were observed. By developing a new technique which obtains the optical image of the array structures without losing information about the QD locations, we were able to further investigate how the QD fluorescence is influenced by spatially controlled array structures.
Collapse
|
50
|
Immunohistological features of hip synovitis in ankylosing spondylitis with advanced hip involvement. Scand J Rheumatol 2009; 38:154-5. [PMID: 19165649 DOI: 10.1080/03009740802409504] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|