1
|
Bue M, Bright E, Thillemann TM, Mosegaard SB, Hansen TB, Klebe T, Mechlenburg I, Stilling M. Osteoporosis does not affect bone mineral density change in the proximal humerus or the functional outcome after open reduction and internal fixation of unilateral displaced 3- or 4-part fractures at 12-month follow-up. J Shoulder Elbow Surg 2023; 32:292-301. [PMID: 35998782 DOI: 10.1016/j.jse.2022.07.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 06/17/2022] [Accepted: 07/07/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND The aim of this prospective study was to investigate bone mineral density (BMD) changes in the proximal humerus of the shoulder during a healing period of 12 months after displaced 3- or 4-part proximal humerus fractures treated with open reduction and internal fixation (ORIF) with an anatomic angular stable locking plate and the influence on fracture healing and functional outcomes. METHODS In a prospective multicenter study, 36 patients (29F and 7M, age range: 38-83) with unilateral displaced 3- or 4-part proximal humerus fractures were included for ORIF. Dual-energy x-ray absorptiometry for osteoporosis status was employed. Postoperative and 6-week, 3-, 6-, and 12-month shoulder radiographs and dual-energy x-ray absorptiometry of the shoulder with BMD measures in 4 templated regions of interest (ROIs) were performed. Functional outcomes, Western Ontario Osteoarthritis of the Shoulder index, Constant score, visual analog scale pain (VAS), and 36-Item Short Form Survey, were collected. RESULTS A total of 17 of 36 patients had osteoporosis. We found no differences in BMD changes, functional outcomes, radiology, or need for revision surgery between the osteoporosis and nonosteoporosis groups. The BMD values gradually declined from baseline to 3-month follow-up in all 4 ROIs of the operated shoulders. All 4 ROIs in the operated shoulder presented with a reduction in BMD at 3, 6, and 12 months compared with baseline, whereas no significant BMD changes were seen in the healthy shoulder during the study period. The functional outcomes displayed an increase in Constant score from 3 to 12 months, but a decrease in domains of the 36-Item Short Form Survey from preinjury to 12 months (physical functioning, general health, and bodily pain). Preinjury and 12-month Western Ontario Osteoarthritis of the Shoulder index, VAS pain at rest, and VAS pain at activity were comparable. CONCLUSION BMD changes appeared swiftly in the proximal humerus, after the treatment of displaced 3- or 4-part fractures with ORIF, particularly affecting the proximal diaphysis of the humerus. Shoulder function was restored to preinjury levels for most of the patients. Osteoporosis may not be regarded as a contraindication for the treatment of displaced 3- or 4-part fractures with ORIF.
Collapse
Affiliation(s)
- Mats Bue
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
| | - Elisabeth Bright
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg, Denmark
| | - Theis Muncholm Thillemann
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
| | - Sebastian Breddam Mosegaard
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark; Department of Orthopaedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Holstebro Regional Hospital, Holstebro, Denmark
| | - Torben Bæk Hansen
- Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark; Department of Orthopaedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Holstebro Regional Hospital, Holstebro, Denmark
| | - Thomas Klebe
- Department of Orthopaedic Surgery, Silkeborg Regional Hospital, Silkeborg, Denmark
| | - Inger Mechlenburg
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
| | - Maiken Stilling
- Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark; Department of Orthopaedic Surgery, University Clinic for Hand, Hip and Knee Surgery, Holstebro Regional Hospital, Holstebro, Denmark.
| |
Collapse
|
2
|
Tøttrup M, Thillemann JK, Thillemann TM, Mechlenburg I, Klebe T, Søballe K, Stilling M. Early offset-increasing migration predicts later revision for humeral head resurfacing implants. A randomized controlled radiostereometry trial with 10-year clinical follow-up. J Orthop Res 2022; 40:2688-2697. [PMID: 35220595 DOI: 10.1002/jor.25298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 02/04/2022] [Accepted: 02/09/2022] [Indexed: 02/04/2023]
Abstract
In a randomized controlled setting, medium-term implant migration and long-term clinical outcomes were compared for the Copeland and the Global C.A.P. humeral head resurfacing implants (HHRI). Thirty-two patients (mean age 63 years) were randomly allocated to a Copeland (n = 14) or Global C.A.P. (n = 18) HHRI. Patients were followed for 5 years with radiostereometry, Constant Shoulder Score, and the Western Ontario Osteoarthritis of the Shoulder Index (WOOS). WOOS and revision status were also obtained cross-sectionally at a mean 10-year follow-up. At the 5-year follow-up, total translation (TT) was 0.75 mm (95% confidence interval [CI]: 0.53-0.97) for the Copeland HHRIs and 1.15 mm (95% CI: 0.85-1.46) for the Global C.A.P. HHRIs (p = 0.04), but the clinical scores were similar at all follow-ups. The cumulative risks of revision at 5 and 10 years were 29% and 43% for Copeland and 35% and 41% for Global C.A.P HHRIs (p > 0.7). No implants were loose at revision, but HHRIs that were later revised followed an early offset-increasing migration pattern with medial translation and lift-off resulting in a mean 0.53 mm (95% CI: 0.18-0.88) higher TT at the 1-year follow-up compared to non-revised HHRIs. In conclusion, the Global C.A.P. HHRI had higher TT compared with the Copeland HHRI, but clinical scores and revision rates were similar. Nonetheless, revision rates were high and challenge the use of HHRIs. Interestingly, an early radiostereometry evaluated HHRI migration pattern with increased off-set predicted later implant revision.
Collapse
Affiliation(s)
- Mikkel Tøttrup
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedics, Aalborg University Hospital, Farsø, Denmark
| | - Janni Kjaergaard Thillemann
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Hospital Unit West, University Clinic of Hand, Hip and Knee Surgery, Holstebro, Denmark
| | - Theis Muncholm Thillemann
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| | - Inger Mechlenburg
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Public Health, Aarhus University, Aarhus, Denmark
| | - Thomas Klebe
- Department of Orthopaedics, Silkeborg Regional Hospital, Silkeborg, Denmark
| | - Kjeld Søballe
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
3
|
Andersen L, Krueger D, Bernatz J, Binkley N, Anderson PA, Grogan B. Humeral BMD can be Measured With DXA and Is Lower in the Surgical Arm After Total Shoulder Arthroplasty. J Clin Densitom 2022; 25:448-455. [PMID: 36114106 DOI: 10.1016/j.jocd.2022.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 08/14/2022] [Indexed: 11/19/2022]
Abstract
BACKGROUND As arthroplasty leads to bone loss, we hypothesized that humeral bone mineral density (BMD) is lower after total shoulder arthroplasty (TSA) in the operative versus non-operative arm. However, there is no clinical approach to measure humeral BMD with dual-energy x-ray absorptiometry (DXA). The purposes of this pilot study were to develop DXA methodology to measure humerus BMD, propose humerus regions of interest (ROIs), compare TSA BMD to the non-operative arm, correlate humeral BMD with standard sites, and evaluate measurement reproducibility. METHODOLOGY Thirty-eight adults 1-5 years post-TSA had standard clinical DXA scans plus full humerus scans using the atypical femur fracture feature; precision was assessed in a subset (n = 32). Six custom ROIs were used to measure BMD throughout the humerus. Radius and humeral BMD were compared between arms by paired t-test and correlated ipsilaterally using Pearson's Correlation. Custom ROI BMD precision was assessed using the International Society for Clinical Densitometry (ISCD) advanced precision calculator. RESULTS Study included 38 subjects (24M/14F), with mean (SD) age and time post-surgery of 69.6 (7.7) years and 2.5 (1.3) years respectively. BMD was lower (p < 0.01) at all custom humerus sites (3.8% to 8.2%) on the surgical side but not different at radius sites. Humeral BMD correlated positively with ipsilateral ultra-distal and 1/3 radius (r = 0.54 to 0.86; p < 0.05). Custom BMD precision (%CV) ranged from 6.0-16.0%. CONCLUSIONS Humerus BMD can be measured using DXA and is lower in the TSA arm. Radius BMD correlated with humeral BMD but was not lower in the surgical arm. BMD precision was worse than usual clinical sites; use of software optimized for the femur is a notable limitation and likely contributes to suboptimal precision. Further study to assess the clinical utility of humeral BMD is needed. Automation and optimization of these measurements should improve precision.
Collapse
Affiliation(s)
- Lucas Andersen
- Osteoporosis Clinical Research Program, University of Wisconsin-Madison.
| | - Diane Krueger
- Osteoporosis Clinical Research Program, University of Wisconsin-Madison
| | - James Bernatz
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison
| | - Neil Binkley
- Osteoporosis Clinical Research Program, University of Wisconsin-Madison
| | - Paul A Anderson
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison
| | - Brian Grogan
- Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison
| |
Collapse
|
4
|
Ten Brinke B, Hesseling B, Eygendaal D, Hoelen MA, Mathijssen NMC. Early fixation of the humeral component in stemless total shoulder arthroplasty : a radiostereometric and clinical study with 24-month follow-up. Bone Joint J 2022; 104-B:76-82. [PMID: 34969283 DOI: 10.1302/0301-620x.104b1.bjj-2021-0945.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. METHODS In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score. RESULTS At two years, median translation along the x-, y-, and z-axis was -0.12 mm (interquartile range (IQR) -0.18 to 0.02), -0.17 mm (IQR -0.27 to -0.09), and 0.09 mm (IQR 0.02 to 0.31). Median rotation around the x-, y-, and z-axis was 0.12° (IQR -0.50 to 0.57), -0.98° (IQR -1.83 to 1.23), and 0.09° (IQR -0.76 to 0.30). Overall, 20 prostheses stabilized within 12 months postoperatively. Four prostheses showed continuous migration between 12 and 24 months. At two-year follow-up, with the exception of one revised prosthesis, all clinical scores improved significantly (median VAS difference at rest: -3.0 (IQR -1.5 to -6.0); OSS 22.0 (IQR 15.0 to 25.0); CMS 29.5 (IQR 15.0 to 35.75); and DASH -30.0 (IQR -20.6 to -41.67) (all p < 0.001)) with the exception of one revised prosthesis. CONCLUSION In conclusion, we found that 20 out of 24 implants stabilized within 12 months postoperatively. The significance of continuous migration in four implants is unclear and future research on the predictive value of early migration for future loosening in TSA is required. Clinical results revealed a clinically relevant improvement. Cite this article: Bone Joint J 2022;104-B(1):76-82.
Collapse
Affiliation(s)
- Bart Ten Brinke
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| | - Brechtje Hesseling
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| | - Denise Eygendaal
- Department of Orthopaedic Surgery, Erasmus Medical Center, Delft, Netherlands
| | - Max A Hoelen
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| | - Nina M C Mathijssen
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft, Netherlands
| |
Collapse
|
5
|
Fraser AN, Bøe B, Fjalestad T, Madsen JE, Röhrl SM. Stable glenoid component of reverse total shoulder arthroplasty at 2 years as measured with model-based radiostereometric analysis (RSA). Acta Orthop 2021; 92:644-650. [PMID: 34196600 PMCID: PMC8635662 DOI: 10.1080/17453674.2021.1943932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Reverse total shoulder arthroplasty (TSA) is used for treating cuff arthropathy, displaced proximal humeral fractures (PHF), and in revision shoulder surgery, despite sparse evidence on long-term results. We assessed stability of the glenoid component in reverse TSA, using model-based RSA.Patients and methods - 20 patients (mean age 76 years, 17 female), operated on with reverse TSA at Oslo University Hospital, in 2015-2017 were included. Indications for surgeries were PHFs, malunion, cuff arthropathy, and chronic shoulder dislocation. RSA markers were placed in the scapular neck, the coracoid, and the acromion. RSA radiographs were conducted postoperatively, at 3 months, 1 year, and 2 years. RSA analysis was performed using RSAcore with Reversed Engineering (RE) modality, with clinical precision < 0.25 mm for all translations (x, y, z) and < 0.7° for rotations (x, z). Scapular "notching" was assessed in conventional radiographs.Results - 1 patient was excluded due to revision surgery. More than half of the patients displayed measurable migration at 2 years: 6 patients with linear translations below 1 mm and 8 patients who showed rotational migration. Except for one outlier, the measured rotations were below 2°. The migration pattern suggested implant stability at 2 years. 10 patients showed radiolographic signs of "notching", and the mean Oxford Shoulder Score (OSS) at 2 years was 29 points (15-36 points).Interpretation - Stability analysis of the glenoid component of reversed total shoulder arthroplasty using reversed engineering (RE) model-based RSA indicated component stability at 2 years.
Collapse
Affiliation(s)
- Alexander Nilsskog Fraser
- Institute of Clinical Medicine; University of Oslo,Diakonhjemmet Hospital,Norway,Correspondence: Alexander Nilsskog FRASER,
| | - Berte Bøe
- Division of Orthopaedic Surgery, Oslo University Hospital
| | - Tore Fjalestad
- Division of Orthopaedic Surgery, Oslo University Hospital
| | - Jan Erik Madsen
- Division of Orthopaedic Surgery, Oslo University Hospital,Institute of Clinical Medicine; University of Oslo
| | | |
Collapse
|
6
|
The value of lateral glenohumeral offset in predicting construct failure in proximal humerus fractures following internal fixation. J Shoulder Elbow Surg 2021; 30:819-825. [PMID: 32763382 DOI: 10.1016/j.jse.2020.07.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 07/12/2020] [Accepted: 07/19/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Proximal humerus fractures are the third most common osteoporosis defining injury in the United States, yet operative fixation of these injuries remains technically challenging. Although several modifiable and nonmodifiable risk factors are correlated with failure of proximal humerus fixation, no study has investigated whether failure to restore glenohumeral offset plays a part in fixation failure. The goals of this study are: (1) to determine if lateral glenohumeral offset (LGHO) and humeral head diameter (HHD) can be measured radiographically with accuracy between observers, (2) to observe whether there is a correlation between failure to operatively restore an anatomic LGHO:HHD ratio and failure of fixation, and (3) if there is a correlation, can any recommendations be made in regard to the ideal LGHO:HHD ratio. METHODS Retrospective review found 183 patients meeting inclusion criteria who underwent operative fixation for proximal humerus fractures between 2005 and 2018. Patients suffering construct failure requiring reoperation were compared with clinically successful surgeries on the basis of age, sex, fracture morphology, head-shaft angle, smoking history, presence or absence of a calcar screw, and LGHO:HHD ratio. The groups were compared using a combination of Student t-tests, χ2, and bivariate and multivariate logistic regression analyses where appropriate. The Student t-test and intraclass correlation coefficient were both used to assess interobserver reliability. RESULTS We found that LGHO and HHD can be measured by independent observers accurately (intraclass correlation coefficient = 0.80, 95% confidence interval: 0.65-0.89). Patients suffering implant failure had a significantly lower LGHO:HHD ratios compared with those who did not (0.94 vs. 1.03, P ≤ .001). The LGHO:HHD ratio was an independent predictor of implant failure even after controlling for other potential risk factors. Patients with an LGHO:HHD of 1.0 or above have a <10% chance of failure compared with a 20% risk with a ratio of 0.9 and a 40% risk at 0.8. CONCLUSION We found the LGHO:HHD ratio to be an independent predictor for construct failure after plate and screw fixation of proximal humerus fractures. Efforts should be made to restore an anatomic ratio of at least 1.0 to minimize the risk of failure.
Collapse
|
7
|
Nyring MRK, Olsen BS, Yilmaz M, Petersen MM, Flivik G, Rasmussen JV. Early migration of stemless and stemmed humeral components after total shoulder arthroplasty for osteoarthritis-study protocol for a randomized controlled trial. Trials 2020; 21:830. [PMID: 33028390 PMCID: PMC7541322 DOI: 10.1186/s13063-020-04763-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Accepted: 09/22/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Glenohumeral osteoarthritis can, in the most severe cases, require surgery with insertion of a shoulder arthroplasty. A design with a stem in the humeral bone canal is currently regarded as the standard treatment option in patients who have an intact rotator cuff function, but complications related to the stem including humeral fractures can have devastating consequences. By using a stemless humeral component, stem-related complications can be reduced. The aim of this study is to compare the Comprehensive Nano stemless total shoulder arthroplasty (intervention group) with the Comprehensive stemmed total shoulder arthroplasty (control group). MATERIALS AND METHODS This is a randomized controlled trial comparing the stemless and the stemmed total shoulder arthroplasty. All Danish citizens with glenohumeral osteoarthritis indicating a total shoulder arthroplasty referred to the orthopedic department at Copenhagen University Hospital in Herlev/Gentofte will be offered participation. The following exclude from participation: below 18 years of age, cognitive or linguistic impairment, insufficient function of the rotator cuff, poor bone quality, and ASA groups 4-5. A total of 122 patients will be included of which 56 will be part of a radiostereometric analysis (RSA) study of humeral component migration. The primary outcomes are magnitude of migration of the humeral component assessed by RSA and patient-reported outcome by Western Ontario Osteoarthritis of the Shoulder index (WOOS). The secondary outcomes are additional patient-reported outcomes, functional outcome, readmission, complications, revisions, and changes in bone mineral density (BMD) of the proximal humerus assessed by duel energy x-ray absorptiometry (DXA) and economy (cost-utility analysis). The patients are examined before the operation and 3, 6, 12, and 24 months postoperative. DISCUSSION To our knowledge, RSA has never been used to access migration of a stemmed or a stemless humeral component nor has the stemmed and the stemless humeral component been compared with regard to pain relief and shoulder function in a randomized clinical trial. Today, the two designs are considered equal in the treatment of osteoarthritis. The study will provide surgeons and patients with information about shoulder arthroplasty for osteoarthritis and assist them in decision-making. TRIAL REGISTRATION ClinicalTrials.gov NCT04105478 . Registered on 25 September 2019.
Collapse
Affiliation(s)
- Marc Randall Kristensen Nyring
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark.
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark.
| | - Bo S Olsen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Müjgan Yilmaz
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark
| | - Michael M Petersen
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Gunnar Flivik
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Orthopedic Surgery, Skaane University Hospital, Lund, Sweden
| | - Jeppe V Rasmussen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
8
|
Geervliet PC, Willems JH, Sierevelt IN, Visser CPJ, van Noort A. Overstuffing in resurfacing hemiarthroplasty is a potential risk for failure. J Orthop Surg Res 2019; 14:474. [PMID: 31888675 PMCID: PMC6936124 DOI: 10.1186/s13018-019-1522-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2019] [Accepted: 12/17/2019] [Indexed: 12/17/2022] Open
Abstract
PURPOSE Literature describes the concern of an overstuffed shoulder joint after a resurfacing humeral head implant (RHHI). The purpose of this study was to evaluate inter-observer variability of (1) the critical shoulder angle (CSA), (2) the length of the gleno-humeral offset (LGHO), and (3) the anatomic center of rotation (COR) in a patient population operated with a Global Conservative Anatomic Prosthesis (CAP) RHHI. The measurements were compared between the revision and non-revision groups to find predictive indicators for failure. METHODS Pre- and postoperative radiographs were retrieved from 48 patients who underwent RHHI from 2007 to 2009 using a Global CAP hemiarthroplasty for end-stage osteoarthritis. This cohort consisted of 36 females (12 men) with a mean age of 77 years (SD 7.5). Two musculoskeletal radiologist and two specialized shoulder orthopedic surgeons measured the CSA, LGHO, and COR of all patients. RESULTS The inter-observer reliability showed excellent reliability for the CSA, LGHO, and the COR, varying between 0.91 and 0.98. The mean COR of the non-revision group was 4.9 mm (SD 2.5) compared to mean COR of the revision group, 8 mm (SD 2.2) (p < 0.01). The COR is the predictor of failure (OR 1.90 (95%Cl 1.19-3.02)) with a cut of point of 5.8 mm. The mean CSA was 29.8° (SD 3.9) There was no significant difference between the revision and non-revision groups (p = 0.34). The mean LGHO was 2.6 mm (SD 3.3) post-surgery. The mean LGHO of the revision group was 3.9 (SD 1.7) (p = 0.04) post-surgery. Despite the difference in mean LGHO, this is not a predictor for failure. CONCLUSION The CSA, LGHO, and COR can be used on radiographs and have a high inter-observer agreement. In contrast with the CSA and LGHO, we found a correlation between clinical failure and revision surgery in case of a deviation of the COR greater than 5 mm. TRIAL REGISTRATION Institutional review board, number: ACLU 2016.0054, Ethical Committee number: CBP M1330348. Registered 7 November 2006.
Collapse
Affiliation(s)
- Pieter C. Geervliet
- NoordWest Clinics, Department of Orthopedic Surgery, Shoulder Unit, Wilhelminalaan 12, 1815 JD Alkmaar, the Netherlands
| | - Jore H. Willems
- NoordWest Clinics, Department of Orthopedic Surgery, Shoulder Unit, Wilhelminalaan 12, 1815 JD Alkmaar, the Netherlands
| | | | | | - Arthur van Noort
- Spaarne Hospital, Spaarnepoort 1, 2134 TM Hoofddorp, the Netherlands
| |
Collapse
|
9
|
Sandau N, Brorson S, Olsen BS, Sørensen AK, Jensen SL, Schantz K, Ovesen J, Rasmussen JV. Low inter-observer agreement among experienced shoulder surgeons assessing overstuffing of glenohumeral resurfacing hemiarthroplasty based on plain radiographs. J Orthop Surg Res 2018; 13:299. [PMID: 30482217 PMCID: PMC6258391 DOI: 10.1186/s13018-018-1008-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 11/19/2018] [Indexed: 02/14/2023] Open
Abstract
Background In a clinical setting, a visual evaluation of post-implant radiographs is often used to assess the restoration of glenohumeral joint anatomy after resurfacing hemiarthroplasty and is a part of the decision-making process, in combination with other parameters, when evaluating patients with inferior clinical results. However, the reliability of this method of visual evaluation has not been reported. The aim of this study was to investigate the inter- and intra-observer agreement among experienced shoulder surgeons assessing overstuffing, implant positioning, and size following resurfacing hemiarthroplasty using plain standardized radiographs. Methods Six experienced shoulder surgeons independently classified implant inclination, size of the implant and if the joint seemed overstuffed, in 219 cases of post-implant radiographs. All cases were classified twice 3 weeks apart. Only radiographs with an anterior-posterior projection with a freely visible joint space were used. Non-weighted Cohen’s kappa values were calculated for each coder pair and the mean used as an estimate of the overall inter-observer agreement. Results The overall inter-observer agreement for implant size (kappa, 0.48 and 0.41) and inclination angle was moderate in both rounds (kappa, 0.46 and 0.44), but only a fair agreement was found concerning the evaluation for stuffing of the joint (kappa, 0.24 and 0.28). Intra-observer agreement for implant size and stuffing ranged from fair to substantial while the agreement for inclination was moderate to substantial. Conclusions Our results indicate that a visual evaluation of plain radiographs may be inadequate to evaluate overstuffing, implant positioning, and size following resurfacing hemiarthroplasty using plain standardized radiographs. Future studies may contribute to elucidate whether reliability increases if consensus on clear definitions and standardized methods of evaluation is made.
Collapse
Affiliation(s)
- Nicolai Sandau
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark.
| | - Stig Brorson
- Department of Orthopedic Surgery, Zealand University Hospital, Lykkebækvej 1, 4600, Køge, Denmark
| | - Bo S Olsen
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark
| | - Anne Kathrine Sørensen
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark
| | - Steen L Jensen
- Department of Orthopedic Surgery, Aalborg University Hospital, Højgårdsvej 11, 9640, Farsø, Denmark
| | - Kim Schantz
- Department of Orthopedic Surgery, Zealand University Hospital, Lykkebækvej 1, 4600, Køge, Denmark
| | - Janne Ovesen
- Department of Orthopedic Surgery, Aarhus University Hospital, Palle Juul Jensens Boulevard 99, 8000, Aarhus, Denmark
| | - Jeppe V Rasmussen
- Department of Orthopedic Surgery, Herlev & Gentofte Hospital, Herlev Ringvej 75, 2730, Herlev, Denmark
| |
Collapse
|
10
|
Holm-Glad T, Reigstad O, Tsukanaka M, Røkkum M, Röhrl SM. High precision and accuracy of model-based RSA for analysis of wrist arthroplasty. J Orthop Res 2018; 36:3053-3063. [PMID: 29873422 DOI: 10.1002/jor.24063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2018] [Accepted: 06/03/2018] [Indexed: 02/04/2023]
Abstract
Radiostereometric analysis (RSA) is a method for measuring micromotion in joint arthroplasties. RSA has never been used in total wrist arthroplasties. We evaluated: (i) the precision of model-based RSA in total wrist arthroplasties measured in a phantom model and in patients; (ii) the number of bone markers necessary to ensure the precision; and (iii) the accuracy of model-based RSA in a phantom model. Reverse engineered models of radial and carpal/metacarpal components of two wrist arthroplasties (ReMotion® and Motec®) were obtained by laser scanning. Precision and accuracy of each arthroplasty were analyzed with regards to translation and rotation along the three coordinate axes. Precision was analyzed in 10 phantom and 30 clinical double examinations for each arthroplasty, and was expressed by a repeatability coefficient. The precision of different numbers and configurations of bone markers in the phantom model were compared. Accuracy was tested in a phantom model where the implants were attached to a micrometer, and was defined as the mean difference between measured and true migration. In the phantom model the precision for translations ranged from 0.03 to 0.14 mm and for rotations from 0.18 to 1.52°. In patients the precision for translations ranged from 0.06 to 0.18 mm, and for rotations from 0.32 to 2.18°. Less than four bone markers resulted in inferior precision. Accuracy ranged from -0.06 to 0.04 mm, and from -0.38 to -0.01°. Y-rotations could not be obtained from the Motec® due to rotational symmetry about the longitudinal axis. We conclude that model-based RSA in total wrist arthroplasties is precise, accurate, and feasible to use for clinical evaluation of micromotion in wrist arthroplasties. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3053-3063, 2018.
Collapse
Affiliation(s)
- Trygve Holm-Glad
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.,Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Ole Reigstad
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.,Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Masako Tsukanaka
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Magne Røkkum
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.,Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Stephan M Röhrl
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.,Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| |
Collapse
|
11
|
Ten Brinke B, Beumer A, Koenraadt KLM, Eygendaal D, Kraan GA, Mathijssen NMC. The accuracy and precision of radiostereometric analysis in upper limb arthroplasty. Acta Orthop 2017; 88:320-325. [PMID: 28464752 PMCID: PMC5434603 DOI: 10.1080/17453674.2017.1291872] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation of prostheses. However, there have been few RSA studies of the upper limb, and the value of RSA of the upper limb is not yet clear. We therefore performed a systematic review to investigate the accuracy and precision of RSA of the upper limb. Patients and methods - PRISMA guidelines were followed and the protocol for this review was published online at PROSPERO under registration number CRD42016042014. A systematic search of the literature was performed in the databases Embase, Medline, Cochrane, Web of Science, Scopus, Cinahl, and Google Scholar on April 25, 2015 based on the keywords radiostereometric analysis, shoulder prosthesis, elbow prosthesis, wrist prosthesis, trapeziometacarpal joint prosthesis, humerus, ulna, radius, carpus. Articles concerning RSA for the analysis of early migration of prostheses of the upper limb were included. Quality assessment was performed using the MINORS score, Downs and Black checklist, and the ISO RSA Results - 23 studies were included. Precision values were in the 0.06-0.88 mm and 0.05-10.7° range for the shoulder, the 0.05-0.34 mm and 0.16-0.76° range for the elbow, and the 0.16-1.83 mm and 11-124° range for the TMC joint. Accuracy data from marker- and model-based RSA were not reported in the studies included. Interpretation - RSA is a highly precise method for measurement of early migration of orthopedic implants in the upper limb. However, the precision of rotation measurement is poor in some components. Challenges with RSA in the upper limb include the symmetrical shape of prostheses and the limited size of surrounding bone, leading to over-projection of the markers by the prosthesis. We recommend higher adherence to RSA guidelines and encourage investigators to publish long-term follow-up RSA studies.
Collapse
Affiliation(s)
- Bart Ten Brinke
- Department of Orthopaedic Surgery, Amphia Ziekenhuis, Breda;,Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft;,Correspondence:
| | | | - Koen L M Koenraadt
- FORCE Foundation, Department of Orthopaedic Surgery, Amphia Ziekenhuis, Breda
| | - Denise Eygendaal
- Department of Orthopaedic Surgery, Amphia Ziekenhuis, Breda;,Department of Orthopaedic Surgery, Academic Medical Center, Amsterdam, the Netherlands
| | - Gerald A Kraan
- Department of Orthopaedic Surgery, Reinier de Graaf Hospital, Delft
| | | |
Collapse
|
12
|
Schmidutz F, Sprecher CM, Milz S, Gohlke F, Hertel R, Braunstein V. Resurfacing of the humeral head: An analysis of the bone stock and osseous integration under the implant. J Orthop Res 2015; 33:1382-90. [PMID: 25808101 DOI: 10.1002/jor.22902] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Accepted: 03/10/2015] [Indexed: 02/04/2023]
Abstract
Cementless-surface-replacement-arthroplasty (CSRA) of the shoulder aims for functional joint restoration with minimal bone loss. Good clinical results have been reported, but due to the radiopaque metal shell no data is available on the structure, osseous integration, and bone stock under the implant. 14 hemi-CSRAs (4 manufacturers) with two geometries (crown [n = 7]/ stem [n = 7] fixation) were retrieved from patients undergoing revision due to glenoidal erosion. Histological sections cutting through the implant centre and bone were analysed. Quantitative histomorphometry evaluated the bone-implant-contact and compared the bone-area to native humeral retrievals (n = 7). The bone-implant-interface was further assessed by scanning-electron-microscopy (SEM) and energy-dispersive-x-ray (EDX). Qualitative histology revealed a reduced and inhomogeneous bone stock. Obvious signs of stress shielding were observed with bone predominantly visible at the stem and implant rim. Quantitative histomorphometry confirmed the significantly reduced bone-area (9.2 ± 3.9% [crown 9.9 ± 4.3%, stem 8.6 ± 3.6%]) compared to native humeri (21.2 ± 9.1%; p < 0.05). Bone-implant-contact was 20.5 ± 5.8% (crown 21.8 ± 6.2%, stem 19.2 ± 5.6%) which was confirmed by SEM and EDX. Altogether, CRSA shows satisfactory bone ingrowth at the interface suggesting sufficient primary stability to allow osseous integration. However, clear signs of stress shielding with an inhomogeneous and reduced bone stock were observed. The impact on the long-term-results is unclear requiring further investigation.
Collapse
Affiliation(s)
- Florian Schmidutz
- AO Research Institute Davos, Switzerland.,Department of Orthopaedic Surgery, University of Munich (LMU), Germany
| | | | - Stefan Milz
- AO Research Institute Davos, Switzerland.,University of Munich (LMU), Anatomische Anstalt, Germany
| | | | | | - Volker Braunstein
- AO Research Institute Davos, Switzerland.,Ortho-Plus Munich, Germany.,Department of General-, Trauma-, Hand and Plastic Surgery, University of Munich (LMU), Germany
| |
Collapse
|
13
|
Radiologic assessment of glenohumeral relationship: reliability and reproducibility of lateral humeral offset. Surg Radiol Anat 2015; 37:363-8. [PMID: 25588981 DOI: 10.1007/s00276-015-1424-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Accepted: 01/08/2015] [Indexed: 10/24/2022]
Abstract
BACKGROUND It has been shown that anatomical reconstruction is an important step in achieving good function after shoulder arthroplasty. It is essential to reconstruct the distance between the coracoid process and greater tubercle as this relates to the moment arm of the deltoid and rotator cuff muscles. This study evaluated the reliability of measurement of the lateral humeral offset (LHO) on plain radiographs and on computed tomography (CT). METHODS Four independent observers performed measurements of LHO on radiographs and CT from 26 patients awaiting shoulder reconstruction. The interobserver reliability and intraobserver reproducibility were assessed. RESULTS Interobserver reliability and intraobserver reproducibility of LHO in axial CT scans were excellent. Plain radiography showed fair to excellent interobserver reliability and variable intraobserver reproducibility. CONCLUSION CT is a reliable tool to measure LHO supporting its use in preoperative planning. When AP radiography is used for preoperative planning the examiner should be aware of its limitations and standardisation protocols should be considered.
Collapse
|
14
|
Evaluation of periprosthetic bone mineral density and postoperative migration of humeral head resurfacing implants: two-year results of a randomized controlled clinical trial. J Shoulder Elbow Surg 2014; 23:1427-36. [PMID: 25220196 DOI: 10.1016/j.jse.2014.05.012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Revised: 05/05/2014] [Accepted: 05/15/2014] [Indexed: 02/01/2023]
Abstract
BACKGROUND Implant migration, bone mineral density (BMD), length of glenohumeral offset (LGHO), and clinical results were compared for the Copeland (Biomet Inc, Warsaw, IN, USA) and the Global C.A.P. (DePuy Int, Warsaw, IN, USA) humeral head resurfacing implants (HHRIs). METHODS The study randomly allocated 32 patients (13 women), mean age 63 years (range, 39-82 years), with shoulder osteoarthritis to a Copeland (n = 14) or Global C.A.P. (n = 18) HHRI. Patients were monitored for 2 years with radiostereometry, dual-energy X-ray absorptiometry, Constant Shoulder Score (CSS), and the Western Ontario Osteoarthritis of the Shoulder Index (WOOS). LGHO was measured preoperatively and 6 months postoperatively. RESULTS At 2 years, total translation (TT) was 0.48 mm (standard deviation [SD], 0.21 mm) for the Copeland and 0.82 mm (SD, 0.46 mm) for the Global C.A.P. (P = .06). Five HHRI were revised, and in the interval before the last follow-up (revision or 2 years), TT of 0.58 mm (SD, 0.61 mm) for revised HHRI was higher (P = .02) than TT of 0.22 mm (SD, 0.17 mm) in nonrevised HHRI. A comparison of TT at the last follow-up (revision or 2 years) found no difference between the HHRIs (P = .12). Periprosthetic BMD decreased initially but increased continuously after 6 months for both HHRIs. At 2 years, BMD was 48% higher around the Copeland HHRI (P = .005). The mean difference in LGHO was significantly higher for the Copeland than for the Global C.A.P. HHRI (P = .02). Clinical results evaluated with CSS and WOOS improved over time for both implant groups (P < .01), with no differences between the groups. CONCLUSION Both implants had only little migration and good clinical results. Periprosthetic BMD and LGHO both increased for the Copeland HHRI more than for the Global C.A.P HHRI.
Collapse
|
15
|
Rasmussen JV, Polk A, Sorensen AK, Olsen BS, Brorson S. Outcome, revision rate and indication for revision following resurfacing hemiarthroplasty for osteoarthritis of the shoulder: 837 operations reported to the Danish Shoulder Arthroplasty Registry. Bone Joint J 2014; 96-B:519-25. [PMID: 24692621 DOI: 10.1302/0301-620x.96b4.31850] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In this study, we evaluated patient-reported outcomes, the rate of revision and the indications for revision following resurfacing hemiarthroplasty of the shoulder in patients with osteoarthritis. All patients with osteoarthritis who underwent primary resurfacing hemiarthroplasty and reported to the Danish Shoulder Arthroplasty Registry (DSR), between January 2006 and December 2010 were included. There were 772 patients (837 arthroplasties) in the study. The Western Ontario Osteoarthritis of the Shoulder (WOOS) index was used to evaluate patient-reported outcome 12 months (10 to 14) post-operatively. The rates of revision were calculated from the revisions reported to the DSR up to December 2011 and by checking deaths with the Danish National Register of Persons. A complete questionnaire was returned by 688 patients (82.2%). The mean WOOS was 67 (0 to 100). A total of 63 hemiarthroplasties (7.5%) required revision; the cumulative five-year rate of revision was 9.9%. Patients aged < 55 years had a statistically significant inferior WOOS score, which exceeded the minimal clinically important difference, compared with older patients (mean difference 14.2 (8.8; 95% CI 19.6; p < 0.001), but with no increased risk of revision. There was no significant difference in the mean WOOS or the risk of revision between designs of resurfacing hemiarthroplasty.
Collapse
Affiliation(s)
- J V Rasmussen
- Herlev University Hospital, Department of Orthopaedic Surgery, Herlev Ringvej 75, 2730 Herlev, Denmark
| | | | | | | | | |
Collapse
|
16
|
The Copeland resurfacing humeral head implant does not restore humeral head anatomy. A retrospective study. Arch Orthop Trauma Surg 2013; 133:615-9. [PMID: 23494113 DOI: 10.1007/s00402-013-1715-8] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2012] [Indexed: 01/14/2023]
Abstract
PURPOSE Recently, there has been concern that the Copeland resurfacing humeral head implant (RHHI) leaves the shoulder joint overstuffed. The purpose of this study was in a selected cohort of patients operated with a Copeland RHHI (1) to evaluate the Length of the Gleno-Humeral Offset (LGHO), (2) to assess the patient-reported quality of life and functional outcome measured by Western Ontario Osteoarthritis of the Shoulder Index (WOOS) and (3) to determine the number of revisions in the cohort. METHODS Pre- and postoperative radiographs were retrieved from 71 of 91 possible patients operated with a Copeland RHHI from 2005 to 2009. The cohort consisted of 30 males and 41 females at a mean age of 61 (38-89) years. One radiologist measured the LGHO and performed double measurements. The WOOS score 1 year after surgery and the number of revisions from all patients operated with a Copeland RHHI in Denmark was requested from the Danish Shoulder Arthroplasty Registry. RESULTS The mean LGHO was 4.99 ± 0.53 cm before surgery and 5.39 ± 0.58 cm after surgery, (p < 0.001). 95 % limits of agreement for measurements of LGHO were ± 0.11 cm. One year after surgery, the WOOS score was 67 for the cohort and 64 for all patients operated with a Copeland RHHI in Denmark. 13 of 71 RHHI in the cohort were revised. CONCLUSION The Copeland RHHI causes significantly increased LGHO and leads to overstuffing in the shoulder joint. The WOOS score in the cohort was comparable to that for all other Danish patients operated with a Copeland RHHI.
Collapse
|