Bavil AY, Eghan-Acquah E, Diamond LE, Barrett R, Carty CP, Barzan M, Nasseri A, Lloyd DG, Saxby DJ, Feih S. Effect of different constraining boundary conditions on simulated femoral stresses and strains during gait. Sci Rep 2024; 14:10808. [PMID: 38734763 PMCID: PMC11088641 DOI: 10.1038/s41598-024-61305-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 05/03/2024] [Indexed: 05/13/2024] Open
Abstract
Finite element analysis (FEA) is commonly used in orthopaedic research to estimate localised tissue stresses and strains. A variety of boundary conditions have been proposed for isolated femur analysis, but it remains unclear how these assumed constraints influence FEA predictions of bone biomechanics. This study compared the femoral head deflection (FHD), stresses, and strains elicited under four commonly used boundary conditions (fixed knee, mid-shaft constraint, springs, and isostatic methods) and benchmarked these mechanics against the gold standard inertia relief method for normal and pathological femurs (extreme anteversion and retroversion, coxa vara, and coxa valga). Simulations were performed for the stance phase of walking with the applied femoral loading determined from patient-specific neuromusculoskeletal models. Due to unrealistic biomechanics observed for the commonly used boundary conditions, we propose a novel biomechanical constraint method to generate physiological femur biomechanics. The biomechanical method yielded FHD (< 1 mm), strains (approaching 1000 µε), and stresses (< 60 MPa), which were consistent with physiological observations and similar to predictions from the inertia relief method (average coefficient of determination = 0.97, average normalized root mean square error = 0.17). Our results highlight the superior performance of the biomechanical method compared to current methods of constraint for both healthy and pathological femurs.
Collapse
Affiliation(s)
- Alireza Y Bavil
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Emmanuel Eghan-Acquah
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Laura E Diamond
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Rod Barrett
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Christopher P Carty
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Martina Barzan
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Azadeh Nasseri
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - David G Lloyd
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - David J Saxby
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia.
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia.
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia.
| | - Stefanie Feih
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia.
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia.
- School of Engineering and Built Environment, Griffith University, Gold Coast, Australia.
| |
Collapse
|
2
|
Liu CD, Hu SJ, Chang SM, Du SC, Chu YQ. Morphological characteristics and a new classification system of the inferior pole fracture of the patella: A computer-tomography-based study. Injury 2024; 55:111256. [PMID: 38049367 DOI: 10.1016/j.injury.2023.111256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/26/2023] [Accepted: 11/27/2023] [Indexed: 12/06/2023]
Abstract
PURPOSE The objective of this study was to measure the morphological characteristics of inferior pole fracture of the patella (IPFP) and develop a practical classification system to determine the corresponding treatment protocols for different IPFPs with specific patterns. METHODS A retrospective radiographic review was performed on a series of 71 patients with IPFP. The preoperative CT data were collected and measured using image processing software. The number of fragments, maximum fracture fragment anteroposterior length (MFFAL), maximum fracture fragment transverse length (MFFTL), fracture fragment coronal angle (FFCA), fracture fragment sagittal angle (FFSA), maximum fracture fragment height (MFFH) and maximum transverse sectional area (MTSA) were analysed. RESULTS The mean number of fracture fragments was 3.8. The average MFFAL was 14.9 mm, the average MFFTL was 23.5 mm, the average FFCA was 92.1°, the average FFSA was 93.0°, the average MFFH was 13.6 mm, and the average MTSA was 299.3 mm2. A new classification system was introduced to describe the varied patterns of IPFP, summarized as (I) simple IPFP; (II) comminuted IPFP; (III) simple IPFP with simple patellar body fracture; and (IV) comminuted patellar fracture involving the inferior pole. With the four-type classification system, 12 type I, 22 type II, 21 type III, and 16 type IV lesions were observed, each with specific morphological characteristics. CONCLUSION Most IPFPs exhibited a diversiform pattern, demonstrating that coverage fixation was likely needed. The four-type classification system might offer a valuable approach to help orthopaedic surgeons make individual treatment plans.
Collapse
Affiliation(s)
- Chen-Dong Liu
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai 200090, Republic of China
| | - Sun-Jun Hu
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai 200090, Republic of China.
| | - Shi-Min Chang
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai 200090, Republic of China
| | - Shou-Chao Du
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai 200090, Republic of China
| | - Yong-Qian Chu
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai 200090, Republic of China
| |
Collapse
|
3
|
Kim S, Mungalpara N, Wangikar R, Tarabichi M, Karam J, Bedi A, Koh J, Amirouche F. Comparative study of locking neutralization plate construct versus tension band wiring with a cannulated screw for patella fractures: experimental and finite element analysis. J Orthop Surg Res 2024; 19:77. [PMID: 38233950 PMCID: PMC10795423 DOI: 10.1186/s13018-024-04538-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 01/04/2024] [Indexed: 01/19/2024] Open
Abstract
Transverse patella fractures, accounting for approximately 1% of Orthopedic injuries, pose intricate challenges due to their vital role in knee mechanics. This study aimed to compare the biomechanical performance of a construct, integrating cannulated screws and an anterior locking neutralization plate, with the conventional tension band wiring technique for treating these fractures. Experimental testing and Finite Element Analysis were employed to evaluate the constructs and gain profound insights into their mechanical behavior. Sixteen cadaveric knees were prepared, and transverse patella fractures were induced at the midpoints using a saw. The plate construct and tension band wire fixation were randomly assigned to the specimens. A cyclic test evaluated the implants' durability and stability, simulating knee movement during extension and flexion. Tensile testing assessed the implants' maximum failure force after cyclic testing, while Finite Element Analysis provided detailed insights into stress distribution and deformation patterns. Statistical analysis was exclusively performed for the experimental data. Results showed the plate enhanced stability with significantly lower deformation (0.09 ± 0.12 mm) compared to wire fixation (0.77 ± 0.54 mm) after 500 cycles (p = 0.004). In tensile testing, the construct also demonstrated higher failure resistance (1359 ± 21.53 N) than wire fixation (780.1 ± 22.62N) (p = 0.007). Finite Element Analysis highlighted distinct stress patterns, validating the construct's superiority. This research presents a promising treatment approach for transverse patella fractures with potential clinical impact and future research prospects. This study presents a promising advancement in addressing the intricate challenges of transverse patella fractures, with implications for refining clinical practice. The construct's improved stability and resistance to failure offer potential benefits in postoperative management and patient outcomes.
Collapse
Affiliation(s)
- Sunjung Kim
- Department of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Nirav Mungalpara
- Department of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Rohan Wangikar
- Department of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Majd Tarabichi
- Department of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Joseph Karam
- Department of Orthopedic Surgery, Orthopedic and Spine Institute, Northshore University Health System, An Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL, 60076, USA
| | - Asheesh Bedi
- Department of Orthopedic Surgery, Orthopedic and Spine Institute, Northshore University Health System, An Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL, 60076, USA
| | - Jason Koh
- Department of Orthopedic Surgery, Orthopedic and Spine Institute, Northshore University Health System, An Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL, 60076, USA
| | - Farid Amirouche
- Department of Orthopedic Surgery, University of Illinois at Chicago, Chicago, IL, USA.
- Department of Orthopedic Surgery, Orthopedic and Spine Institute, Northshore University Health System, An Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL, 60076, USA.
| |
Collapse
|
4
|
Chang CH, Shih CA, Kuan FC, Hong CK, Su WR, Hsu KL. Surgical treatment of inferior pole fractures of the patella: a systematic review. J Exp Orthop 2023; 10:58. [PMID: 37261559 DOI: 10.1186/s40634-023-00622-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 05/17/2023] [Indexed: 06/02/2023] Open
Abstract
PURPOSE This study aimed to comprehensively review the existing evidence concerning surgical treatment of inferior pole fractures of the patella and to report the outcomes and complications of different fixation techniques. METHOD This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Searches of PubMed, Scopus, and Web of Science were conducted in March 2023. Studies were screened against predecided inclusion and exclusion criteria. The extracted data included fracture characteristics, surgical techniques, and radiographic and functional outcomes. The Methodological Index for Non-Randomized Studies (MINORS) quality assessment tool was used to assess the eligible literature. The primary outcome was postoperative range of motion of different surgical methods, and the secondary outcomes were other clinical results and complications. RESULTS A total of 42 studies satisfied all the inclusion criteria and were deemed suitable for review. Fourteen case-control studies and 28 case series were selected, for a total of 1382 patients with a mean age of 51.0 years (range = 11-90). The follow-up period ranged from 6 to 300 months. The surgical techniques were categorized based on the device used as follows: (1) rigid fixation device; (2) tensile fixation device; (3) mixed device; and (4) extra-patella device. CONCLUSION Regarding the outcomes following surgical treatment of inferior pole fractures of the patella, the postoperative range of motion (ROM) of each technique ranged from 120° to 135°, with the exception of that involving the patellotibial wire which had poorer outcomes. The lowest functional score was also found in those using the patellotibial wire. Complications after surgery are rare, but approximately half of the patients required additional surgery for implant removal, particularly those whose initial surgery involved rigid fixation devices. It's worth noting that bony fragment excision is no longer recommended, and the combined use of multiple surgical devices is now more common.
Collapse
Affiliation(s)
- Chih-Hsun Chang
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Rd, Tainan, Taiwan, R.O.C
- Division of Orthopaedics, Department of Surgery, National Cheng Kung University Hospital Dou Liou Branch, National Cheng Kung University, Yunlin, Taiwan
- Skeleton Materials and Bio-Compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Chien-An Shih
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Rd, Tainan, Taiwan, R.O.C
- Skeleton Materials and Bio-Compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Fa-Chuan Kuan
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Rd, Tainan, Taiwan, R.O.C
- Skeleton Materials and Bio-Compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
- Division of Traumatology, National Cheng Kung University Medical Center, Tainan, Taiwan
| | - Chih-Kai Hong
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Rd, Tainan, Taiwan, R.O.C
- Division of Orthopaedics, Department of Surgery, National Cheng Kung University Hospital Dou Liou Branch, National Cheng Kung University, Yunlin, Taiwan
- Skeleton Materials and Bio-Compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Wei-Ren Su
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Rd, Tainan, Taiwan, R.O.C
- Skeleton Materials and Bio-Compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Kai-Lan Hsu
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, 138 Sheng-Li Rd, Tainan, Taiwan, R.O.C..
- Skeleton Materials and Bio-Compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
- Division of Traumatology, National Cheng Kung University Medical Center, Tainan, Taiwan.
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
5
|
Li SJ, Tiwari SR, Chang SM, Du SC, Zhang YQ. Separate vertical wiring plus bilateral anchor girdle suturing fixation for the fractures of the inferior pole of the patella. J Orthop Surg Res 2023; 18:176. [PMID: 36890520 PMCID: PMC9997027 DOI: 10.1186/s13018-023-03649-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Accepted: 02/25/2023] [Indexed: 03/10/2023] Open
Abstract
BACKGROUND The fixation of inferior pole fractures of the patella (IPFPs) is still a great challenge for surgeons. MATERIALS AND METHODS We introduced a new fixation method for IPFP fixation, that is, separate vertical wiring plus bilateral anchor girdle suturing fixation (SVW-BSAG). Three finite element models including the anterior tension band wiring (ATBW) model, separate vertical wiring (SVW) model and SVW-BSAG model, were built to evaluate the fixation strength of different fixation methods. A total of 41 consecutive patients with IPFP injury were enrolled in this retrospective study, including 23 patients in the ATBW group and 18 patients in the SVW-BSAG group. The operation time, radiation exposure, full weight-bearing time, Bostman score, extension lag versus contralateral healthy leg, Insall-Salvati ratio, and radiograph outcomes were employed to assess and compare the ATBW group and SVW-BSAG group. RESULTS The finite element analysis confirmed that the SVW-BSAG fixation method was as reliable as the ATBW fixation method in terms of fixed strength. Through retrospective analysis, we found that there was no significant difference between the SVW-BSAG and ATBW groups in age, sex, BMI, fracture side, fracture type, or follow-up time. There were no significant differences between the two groups in the Insall-Salvati ratio, 6-month Bostman score, and fixation failure. Compared with the ATBW group, the SVW-BSAG group showed advantages in intraoperative radiation exposure, full weight-bearing time, and extension lag versus the contralateral healthy leg. CONCLUSION The finite element analysis and clinical results showed that SVW-BSAG fixation methods are a reliable and valuable for IPFP treatment.
Collapse
Affiliation(s)
- Shi-Jie Li
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai, 200090, China
| | - Shashi Ranjan Tiwari
- Department of Orthopedic Surgery, Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Shi-Min Chang
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai, 200090, China.
| | - Shou-Chao Du
- Department of Orthopaedic Surgery, Yangpu Hospital, School of Medicine, Tongji University, 450 Tengyue Road, Shanghai, 200090, China
| | - Ying-Qi Zhang
- Department of Orthopedic Surgery, Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| |
Collapse
|
6
|
Jian Z, Jia J, Zeng L, Li D, Zhang X, Zhou J, Yi C, Yu B, Ao R. Ring-Pins combined with cable cerclage for the fixation of displaced inferior patellar pole fractures. Front Surg 2023; 9:1043822. [PMID: 36726942 PMCID: PMC9884973 DOI: 10.3389/fsurg.2022.1043822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 12/16/2022] [Indexed: 01/17/2023] Open
Abstract
Objective The study aimed to present the clinical results and complication rates of ring-pins with cable cerclage for treating the inferior pole of patella fracture. Method A study that retrospectively reviewed consecutive patients of the displaced inferior pole of patella fracture (AO/OTA 34-A1) operated with a ring-pin tension band using cable cerclage between October 2015 and October 2017 was performed. The duration of surgery, motion range of the knee, function outcomes, and complications were recorded. Results The average follow-up of 31 patients was 21 months. The mean operation time was 50 min. Fractures in all 31 patients healed at a mean duration of 8 weeks. There was no infection, no withdrawing of ring-pins, no implant breakage, and no loss of fracture reduction. The mean range of motion was 120°, and no patient complained of implant irritation at the final follow-up. The average Bostman score was 29.0 points, and 28 patients graded clinical outcomes excellent and 3 patients graded clinical outcomes good at the last follow-up. Conclusions Ring-pin combined with cable cerclage for treating the displaced inferior pole of patellar fracture is simple, and the postoperative internal fixation-related complication rate is low. It is a good choice for treating the displaced inferior pole of the patellar fracture.
Collapse
Affiliation(s)
- Zhen Jian
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Jianbo Jia
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Langqing Zeng
- Department of Orthopedics, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China,Department of Orthopedics, Zhuhai People's Hospital, Zhuhai Hospital Affliated with Jinan University, Zhuhai, China
| | - Dejian Li
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Xu Zhang
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Jianhua Zhou
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Chengqing Yi
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Baoqing Yu
- Department of Orthopedics, Shanghai Pudong New Area People's Hospital, Shanghai, China,Correspondence: Rongguang Ao Baoqing Yu
| | - Rongguang Ao
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China,Department of Orthopedics, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China,Correspondence: Rongguang Ao Baoqing Yu
| |
Collapse
|
7
|
Du B, Ma T, Bai H, Lu Y, Xu Y, Yang Y, Zhang K, Li Z, Li M. Efficacy comparison of Kirschner-wire tension band combined with patellar cerclage and anchor-loop plate in treatment of inferior patellar pole fracture. Front Bioeng Biotechnol 2022; 10:1010508. [PMID: 36324895 PMCID: PMC9618880 DOI: 10.3389/fbioe.2022.1010508] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 09/27/2022] [Indexed: 11/20/2022] Open
Abstract
Objective: This study aimed to compare the biomechanical stability and clinical efficacy of the Kirschner-wire (K-wire) tension band combined with patellar cerclage and an anchor-loop plate (ALP) in treating inferior-pole patellar fracture. Methods: The finite element model was established to analyze the mechanical properties of a K-wire tension band combined with patellar cerclage and ALP fixation in the treatment of inferior patellar pole fracture. The clinical data of 49 patients with patellar inferior-pole fracture (AO/OTA 34 A1) admitted to our hospital from January 2017 to July 2021 were retrospectively analyzed. Among these, 28 cases were fixed with ALPs (ALP group) and 21 cases were fixed with K-wire tension bands combined with patellar cerclage (K-wire group). By reviewing the medical records and follow-up results, we compared the operation time, final knee joint activity, incidence of secondary surgery, postoperative complications, and joint function recovery between the two groups. Results: The biomechanical analysis of the finite element model showed that the maximum displacement of the K-wire group was 1.87 times that of the ALP group. The maximum stress of the K-wire group was 1.34 times that of the ALP group. The maximum stress of the pole bone in the K-wire group was 13.89 times that of the ALP group. The average follow-up times of the K-wire group and ALP group were similar (p > 0.05), and the average ages of the two groups were similar (p > 0.05). The operation time of the ALP group was significantly shorter than that of the K-wire group (p < 0.05).The final knee joint activity of the ALP group was significantly greater than that of the K-wire group (p < 0.05). The Bostman patellar fracture function score of the ALP group was significantly better than that of the K-wire group at 3 and 9 months after operation (p < 0.05). Postoperative complications of the two groups included 1 case (3.6%) in the ALP group with internal fixation-stimulation complications and, in the K-wire group, 3 cases (14.3%) with internal fixation stimulation complications and 1 case (4.8%) with infection. Conclusion: The ALP and K-wire tension band combined with patella cerclage models were tested at 500 N, and no damage occurred, indicating that the newly designed ALP is safe in mechanical structure. The ALP has better therapeutic effect in biomechanical stability, postoperative complications, secondary surgery, and knee function. This technique is an effective method for the treatment of inferior-pole patellar fracture.
Collapse
Affiliation(s)
- Bing Du
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
- Medical College of Yan’an University, Yan’an, China
| | - Teng Ma
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
| | - Huanan Bai
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
| | - Yao Lu
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
| | - Yibo Xu
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
| | - Yanling Yang
- Medical College of Yan’an University, Yan’an, China
| | - Kun Zhang
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
| | - Zhong Li
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
- *Correspondence: Zhong Li, ; Ming Li,
| | - Ming Li
- Honghui Hospital, Xi’an Jiaotong University, Xi’an, China
- *Correspondence: Zhong Li, ; Ming Li,
| |
Collapse
|