1
|
Olszewski J. Electrical safety assessment of a prototype device for electromagnetic stimulation of the ear in patients with tinnitus. OTOLARYNGOLOGIA POLSKA 2024; 78:50-54. [PMID: 38623855 DOI: 10.5604/01.3001.0053.9036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
<b><br>Aim:</b> The aim of the study was to evaluate the results of electrical safety results of a prototype electromagnetic ear stimulation device in patients with tinnitus.</br> <b><br>Material and methods:</b> The electrical safety tests of the prototype device for electro- and magnetostimulation of the hearing organ were carried out at the Center for Attestation and Certification Tests in Gliwice. The tests concerned selected parameters including the PN-EN standard.</br> <b><br>Results:</b> Safety studies of the prototype electrical stimulation device for the ear in patients with tinnitus were necessary to perform the planned further preclinical studies. Obtained results regarding: identification and labeling of the device; protection against electric shock; checking protective earthing, functional earthing and potential equalization; checking the leakage current and auxiliary currents of the patient; checking the distances through the solid insulation and the use of thin insulating spacers; checking the electrical strength of the device insulation; checking protection against mechanical hazards of the device; checking the risk associated with surfaces, corners and edges, and checking the protection against excessive temperatures and other threats comply with the standard PN-EN.</br> <b><br>Conclusions:</b> No risk to the patient and medical staff. Tests of protection against mechanical hazards of the device have shown that the only movable part whose contact with the patient could cause an unacceptable risk is the fan installed inside the housing.</br>.
Collapse
Affiliation(s)
- Jurek Olszewski
- Clinic of Otolaryngology, Laryngological Oncology, Audiology and Phoniatrics at the 2nd Department of Otolaryngology of the Medical University of Lodz, Department of Polish Dialectology and Logopedics of the University of Lodz, Poland
| |
Collapse
|
2
|
Olszewski J. Evaluation the results of electromagnetic compatibility of a prototype device for ear stimulation in patients with tinnitus. OTOLARYNGOLOGIA POLSKA 2023; 77:37-42. [PMID: 38706260 DOI: 10.5604/01.3001.0053.6157] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2024]
Abstract
<b><br>Aim:</b> The aim of the study was to evaluate the results of electromagnetic compatibility of a prototype device for ear stimulation in patients with tinnitus.</br> <b><br>Material and methods:</b> The electromagnetic compatibility tests of the prototype device for electro- and magnetostimulation of the hearing organ were carried out at the Center for Attestation and Certification Tests OBAC Sp. z o. o. in Gliwice in 2020. The following product standards were used: PN-EN 60601-1-2:2015-11 - medical electrical equipment (general requirements for basic safety and essential functioning; PN-EN 55011:2012 - industrial, scientific and medical equipment [characteristics of radio frequency disturbances] ) PN-EN 61000-3-2:2014-10 - electromagnetic compatibility (EMC), permissible levels of harmonic current emissions (phase load current ≤ 16 A).</br> <b><br>Results:</b> The level of expanded uncertainty in the measurement of conducted disturbances in the range of 0.150-30MHz does not exceed the level specified in the PN-EN-55016-4-2:2011 standard. In the study of the emission of radiated disturbances up to 1GHz in the frequency range of 30-1000MHz (PN-EN 55011:2012 standard), it was found that the setting of the EUT during the tests was in accordance with the requirements of the standard. The level of expanded uncertainty in the measurement of radiated disturbances in the 30-1000MHz range does not exceed the level specified in the PN-EN 55016-4-2:2011 standard. The measured current harmonic levels (phase power supply current ≤16A) with a frequency range of 50Hz-2kHz do not exceed the permissible levels specified in the PN-EN 61000-3-2:2014-10 standard. The test of resistance to the magnetic field at the frequency of the power grid (PN-EN 61000-4-8: 2010 standard also showed that the setting of the EUT during the tests was in accordance with the requirements of the standard and the result was positive.</br> <b><br>Conclusions:</b> Testing of immunity to radiated radio frequency electromagnetic field (PN-EN 61000-4-3:2007 +A1:2008+A2:2011 standard) and testing of resistance to magnetic field at power frequency (PN-EN 61000-4-8 standard :2010) did not exceed the level specified in the standard and showed a positive result. The measured harmonic levels of the network current (phase supply current ≤16A) with the frequency range 50Hz-2kHz do not exceed the permissible levels specified in the PN-EN 61000- 3-2:2014-10 standard for a class A device.</br>.
Collapse
Affiliation(s)
- Jurek Olszewski
- Clinic of Otolaryngology, Laryngological Oncology, Audiology and Phoniatrics at the 2nd Department of Otolaryngology of the Medical University of Lodz, Department of Polish Dialectology and Logopedics of the University of Lodz, Poland
| |
Collapse
|
3
|
Grundfast KM, Jamil TL. Evaluation and Management of Tinnitus: Are There Opportunities for Improvement? Otolaryngol Head Neck Surg 2023; 168:45-58. [PMID: 35349391 DOI: 10.1177/01945998221088286] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Accepted: 03/02/2022] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To review current information about diagnosis and management of tinnitus aiming to identify opportunities for achieving a cost-effective, efficient, evidence-based approach that meets the needs of tinnitus sufferers. DATA SOURCES PubMed/MEDLINE. REVIEW METHODS In total, 249 relevant published reports were reviewed. Pertinent keywords and MeSH terms identified reports via PubMed and EMBASE. Acknowledged experts were consulted on ways to improve tinnitus management. CONCLUSIONS There may be opportunities to improve evaluation and management of patients with tinnitus using modern modes of communication and a multidisciplinary therapeutic approach. IMPLICATIONS FOR PRACTICE Tinnitus can adversely affect quality of life while being time-consuming and costly to evaluate and manage. Based on both personal experience and the reports of others, patients with tinnitus who choose to see a physician primarily want to know two things: (1) that the tinnitus that is so distressing will not remain at the same level of severity forever and (2) that something can be done to help cope with the tinnitus that is so annoying. Recent advancements in internet communications, social media, information technology, artificial intelligence, machine learning, holistic medical care, mind-body integrative health care, and multidisciplinary approaches in medical therapeutics may be possibly making new ways of meeting the needs of patients with tinnitus.
Collapse
Affiliation(s)
- Kenneth M Grundfast
- Boston University School of Medicine, Boston, Massachusetts, USA
- Department of Otolaryngology-Head and Neck Surgery, Boston Medical Center, Boston, Massachusetts, USA
- Otology Service, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA
| | - Taylor L Jamil
- Boston University School of Medicine, Boston, Massachusetts, USA
- Boston University School of Public Health, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Olszewski J, Bielińska M, Kowalski AJ. Assessment of Subjective Tinnitus Treatment Results Using a Prototype Device for Electrical and Magnetic Stimulation of the Ear-Preliminary Study. LIFE (BASEL, SWITZERLAND) 2022; 12:life12060918. [PMID: 35743949 PMCID: PMC9225432 DOI: 10.3390/life12060918] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 06/11/2022] [Accepted: 06/14/2022] [Indexed: 11/16/2022]
Abstract
Background: The aim of the study was to evaluate the effectiveness of subjective tinnitus treatment in patients with cochlear sensorineural hearing loss with magnetic ear stimulation using a prototype device. Since the 1970s, studies have been conducted on the use of electrical stimulation of the ear in the treatment of tinnitus. The available literature contains various hypotheses about the influence of electrical stimulation of the ear on tinnitus. Material and Methods: Preclinical studies were performed for 100 patients, 40 women and 60 men (124 ears in total), aged 38-72 years, treated for tinnitus. A subjective assessment of the loudness of tinnitus was performed, and the frequency and intensity as well as hearing threshold were determined using a prototype device for electro-magnetic stimulation of the ear. The treatment cycle consisted of 10 five-minute stimulations performed daily 5 times a week. Results: Before treatment, persistent tinnitus was found in 100 ears (80.6%) and periodic tinnitus in 24 ears (19.4%). Immediately after treatment, persistent tinnitus was present only in 50 ears (40.3%) and periodic tinnitus in 40 ears (32.3%). Complete resolution of tinnitus was noted in 34 ears (27.4%). On the other hand, the examination performed 3 months after the treatment showed persistent tinnitus in 40 ears (32.3%) and periodic tinnitus in 50 ears (40.3%), and complete resolution of tinnitus was recorded in 34 ears (27.4%). Based on the VAS analog scale, there was an improvement in tinnitus in 98 ears (79.0%) immediately after treatment and no improvement in 26 ears (20.0%). The mean VAS scale before treatment was 4.9 points, after treatment it was 2.1 points and 3 months after treatment it was 1.9 points. Conclusions: The preliminary research results show the high effectiveness of magnetic stimulation in the treatment of tinnitus with the use of a prototype device for electromagnetic stimulation of the ear. There was no negative effect of the stimulation on hearing or tinnitus.
Collapse
|
5
|
Symptom dimensions to address heterogeneity in tinnitus. Neurosci Biobehav Rev 2022; 134:104542. [PMID: 35051524 DOI: 10.1016/j.neubiorev.2022.104542] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 01/11/2022] [Accepted: 01/14/2022] [Indexed: 01/10/2023]
Abstract
Tinnitus, the auditory phantom percept, is a well-known heterogenous disorder with multiple subtypes. Researchers and clinicians have tried to classify these subtypes according to clinical profiles, aetiologies, and response to treatment with little success. The occurrence of overlapping tinnitus subtypes suggests that the disorder exists along a continuum of severity, with no clear distinct boundaries. In this perspective, we propose a neuro-mechanical framework, viewing tinnitus as a dimensional disorder which is a complex interplay of its behavioural, biological and neurophysiological phenotypes. Moreover, we explore the potential of these dimensions as interacting networks without a common existing cause, giving rise to tinnitus. Considering tinnitus as partially overlapping, dynamically changing, interacting networks, each representing a different aspect of the unified tinnitus percept, suggests that the interaction of these networks determines the phenomenology of the tinnitus, ultimately leading to a dimensional spectrum, rather than a categorical subtyping. A combination of a robust theoretical framework and strong empirical evidence can advance our understanding of the functional mechanisms underlying tinnitus and ultimately, improve treatment strategies.
Collapse
|
6
|
Assouly KKS, Dullaart MJ, Stokroos RJ, van Dijk B, Stegeman I, Smit AL. Systematic Review on Intra- and Extracochlear Electrical Stimulation for Tinnitus. Brain Sci 2021; 11:brainsci11111394. [PMID: 34827395 PMCID: PMC8615734 DOI: 10.3390/brainsci11111394] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 10/08/2021] [Accepted: 10/19/2021] [Indexed: 12/17/2022] Open
Abstract
Several electrical stimulation patterns of the auditory nerve have been described for tinnitus relief, but there is no consensus on the most effective stimulation pattern. Therefore, we aim to systematically review the literature on the effect of intra- and extracochlear electrical stimulation patterns as a treatment option for patients with tinnitus. Only studies on intra- and extracochlear electrical stimulation for patients with tinnitus were included if the stimulation used did not concern standardized CI stimulation patterns to primarily rehabilitate hearing loss as intervention. A total of 34 studies met the inclusion criteria, with 10 studies (89 patients) on intracochlear electrical stimulation and 25 studies on extracochlear electrical stimulation (1109 patients). There was a high to medium risk of bias in 22 studies, especially due to lack of a non-exposed group and poor selection of the exposed group. All included studies showed subjective tinnitus improvement during or after electrical stimulation, using different stimulation patterns. Due to methodological limitations and low reporting quality of the included studies, the potential of intra- and extracochlear stimulation has not been fully explored. To draw conclusions on which stimulation patterns should be optimized for tinnitus relief, a deeper understanding of the mechanisms involved in tinnitus suppression is needed.
Collapse
Affiliation(s)
- Kelly K. S. Assouly
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, 3584 Utrecht, The Netherlands; (M.J.D.); (R.J.S.); (I.S.); (A.L.S.)
- UMC Utrecht Brain Center, University Medical Center Utrecht, 3584 Utrecht, The Netherlands
- Cochlear Technology Center, 2800 Mechelen, Belgium;
- Correspondence: ; Tel.: +31-88-755-6644
| | - Max J. Dullaart
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, 3584 Utrecht, The Netherlands; (M.J.D.); (R.J.S.); (I.S.); (A.L.S.)
| | - Robert J. Stokroos
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, 3584 Utrecht, The Netherlands; (M.J.D.); (R.J.S.); (I.S.); (A.L.S.)
- UMC Utrecht Brain Center, University Medical Center Utrecht, 3584 Utrecht, The Netherlands
| | - Bas van Dijk
- Cochlear Technology Center, 2800 Mechelen, Belgium;
| | - Inge Stegeman
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, 3584 Utrecht, The Netherlands; (M.J.D.); (R.J.S.); (I.S.); (A.L.S.)
- UMC Utrecht Brain Center, University Medical Center Utrecht, 3584 Utrecht, The Netherlands
| | - Adriana L. Smit
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, 3584 Utrecht, The Netherlands; (M.J.D.); (R.J.S.); (I.S.); (A.L.S.)
- UMC Utrecht Brain Center, University Medical Center Utrecht, 3584 Utrecht, The Netherlands
| |
Collapse
|
7
|
Tran P, Richardson ML, Zeng FG. Input-Output Functions in Human Heads Obtained With Cochlear Implant and Transcranial Electric Stimulation. Neuromodulation 2019; 24:1402-1411. [PMID: 31710408 DOI: 10.1111/ner.13065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 09/18/2019] [Accepted: 09/23/2019] [Indexed: 11/27/2022]
Abstract
OBJECTIVES Electric stimulation is used to treat a number of neurologic disorders such as epilepsy and depression. However, delivering the required current to far-field neural targets is often ineffective because of current spread through low-impedance pathways. Here, the specific aims are to develop an empirical measure for current passing through the human head and to optimize stimulation strategies for targeting deeper structures, including the auditory nerve, by utilizing the cochlear implant (CI). MATERIALS AND METHODS Outward input/output (I/O) functions were obtained by CI stimulation and recording scalp potentials in five CI subjects. Conversely, inward I/O functions were obtained by noninvasive transcranial electric stimulation (tES) and recording intracochlear potentials using the onboard recording capability of the CI. RESULTS I/O measures indicate substantial current spread, with a maximum of 2.2% gain recorded at the inner ear target during tES (mastoid-to-mastoid electrode configuration). Similarly, CI stimulation produced a maximum of 1.1% gain at the scalp electrode nearest the CI return electrode. Gain varied with electrode montage according to a point source model that accounted for distances between the stimulating and recording electrodes. Within the same electrode montages, current gain patterns varied across subjects suggesting the importance of tissue properties, geometry, and electrode positioning. CONCLUSION These results provide a novel objective measure of electric stimulation in the human head, which can help to optimize stimulation parameters that improve neural excitation of deep structures by reducing the influence of current spread.
Collapse
Affiliation(s)
- Phillip Tran
- Center for Hearing Research, University of California, Irvine, CA, USA
| | | | - Fan-Gang Zeng
- Center for Hearing Research, University of California, Irvine, CA, USA
| |
Collapse
|
8
|
Peter N, Liyanage N, Pfiffner F, Huber A, Kleinjung T. The Influence of Cochlear Implantation on Tinnitus in Patients with Single-Sided Deafness: A Systematic Review. Otolaryngol Head Neck Surg 2019; 161:576-588. [DOI: 10.1177/0194599819846084] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
ObjectivesThis systematic review provides an overview of the available studies (published by January 29, 2018) with descriptive data analysis about the influence of cochlear implantation on tinnitus in patients with single-sided deafness (SSD).Data SourcesPubMed, EMBASE, Web of Science, Cochrane Library, and Google Scholar.Review MethodsOriginal studies about the influence of cochlear implantation on tinnitus, measured with different tinnitus questionnaires or visual analog scale, in patients with SSD were included. The pre- and postimplantation tinnitus scores of the included studies were extracted for the further systematic review.ResultsThe systematic search yielded 1028 studies. After evaluating titles, abstracts, and full texts, 1011 of these were dismissed. From the remaining 17 studies, 4 showed a low directness of evidence or high risk of bias and were therefore excluded. Due to the nature of cochlear implantation in SSD, only cohort studies and no randomized trials exist, which limits the evaluation in a systematic review. Generally, the mean tinnitus questionnaire scores decreased after cochlear implantation in these 13 studies with a total of 153 patients. The most widely used tinnitus questionnaire was the Tinnitus Handicap Inventory. In these studies, 34.2% of patients demonstrated complete suppression, 53.7% an improvement, 7.3% a stable value, and 4.9% an increase of tinnitus, and none of the patients reported an induction of tinnitus.ConclusionThis review shows a clear improvement of tinnitus complaints after cochlear implantation in patients with SSD. Therefore, tinnitus might be considered as an additional indication for cochlear implantation in SSD.
Collapse
Affiliation(s)
- Nicole Peter
- Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Nuwan Liyanage
- Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Flurin Pfiffner
- Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Alexander Huber
- Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Tobias Kleinjung
- Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
| |
Collapse
|
9
|
Mielczarek M, Norena A, Schlee W, Olszewski J. Excitation of the Auditory System as a Result of Non-invasive Extra-Cochlear Stimulation in Normal Subjects and Tinnitus Patients. Front Neurosci 2018; 12:146. [PMID: 29628872 PMCID: PMC5876290 DOI: 10.3389/fnins.2018.00146] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2017] [Accepted: 02/22/2018] [Indexed: 11/13/2022] Open
Abstract
One of possible approach that may suppress tinnitus is electrical stimulation of the ear. At first invasive techniques were used (promontory or round window stimulation), nowadays a non-invasive method, namely hydrotransmissive electric stimulation (ES) through external acoustic canal, has been developed. The aim of the study is to investigate the effect of applying ES with positive and negative current polarities on the ears of healthy subjects and on the tinnitus ears of patients with tinnitus. This comparison further clarifies the mechanisms of operation of non-invasive extra-cochlear ear ES. A second aim is to assess the effects of ES on tinnitus in tinnitus patients. The material was composed of two groups: tinnitus group—49 patients suffering from tinnitus, and healthy students group—34 healthy individuals. ES was performed with the use of a custom-made apparatus. The active, silver probe–was immersed inside saline filling external ear canal. The passive electrode was placed on the forehead. Positive and next negative DC stimulation was provided with the use following frequencies: 0.25, 1, 2, 3, 4, 5, 6, 7, 8 kHz. We checked for the presence of the auditory percept (AP) and, if AP was present, the minimum current amplitude necessary to produce AP was measured. In our research both positive and negative polarities were efficient to evoke AP in the participants. This effect, however, was more pronounced for positive polarity in no tinnitus and normal hearing individuals (healthy students group). In the tinnitus group, current intensity needed to evoke AP was higher than in the healthy students group. However, comparing normal hearing vs. hearing loss patients within the tinnitus group, we did not observe the relationship between hearing threshold and current intensity evoking AP. Afterwards, we analyzed the effect of multi-frequency ES on tinnitus. It appeared to be effective in 75% of tinnitus ears (with a high score of disappearance–22%). Our study proved that extracochlear ES with positive and negative current was efficient to stimulate the auditory system. Stimulating tinnitus ears with two polarities we obtained a higher ratio of improvement (75%) comparing to positive stimulations.
Collapse
Affiliation(s)
- Marzena Mielczarek
- Department of Otolaryngology, Laryngological Oncology, Audiology and Phoniatrics, Medical University of Lodz, Lodz, Poland
| | - Arnaud Norena
- Laboratoire Neurosciences Intégratives et Adaptatives, Aix-Marseille Université, Marseille, France
| | - Winfried Schlee
- Department for Psychiatry and Psychotherapy, University of Regensburg, Regensburg, Germany
| | - Jurek Olszewski
- Department of Otolaryngology, Laryngological Oncology, Audiology and Phoniatrics, Medical University of Lodz, Lodz, Poland
| |
Collapse
|
10
|
Hesse G. Evidence and evidence gaps in tinnitus therapy. GMS CURRENT TOPICS IN OTORHINOLARYNGOLOGY, HEAD AND NECK SURGERY 2016; 15:Doc04. [PMID: 28025604 PMCID: PMC5169077 DOI: 10.3205/cto000131] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
A nearly endless number of procedures has been tried and in particular sold for the treatment of tinnitus, unfortunately they have not been evaluated appropriately in an evidence-based way. A causal therapy, omitting the tinnitus still does not exist, actually it cannot exist because of the various mechanisms of its origin. However or perhaps because of that, medical interventions appear and reappear like fashion trends that can never be proven by stable and reliable treatment success. This contribution will discuss and acknowledge all current therapeutic procedures and the existing or non-existing evidence will be assessed. Beside external evidence, the term of evidence also encompasses the internal evidence, i.e. the experience of the treating physician and the patient's needs shall be included. While there is no evidence for nearly all direct procedures that intend modulating or stimulating either the cochlea or specific cervical regions such as the auditory cortex, there are therapeutic procedures that are acknowledged in clinical practice and have achieved at least a certain degree of evidence and generate measurable effect sizes. Those are in particular habituation therapy and psychotherapeutic measures, especially if they are combined with concrete measures for improved audio perception (hearing aids, CI, hearing therapies).
Collapse
Affiliation(s)
- Gerhard Hesse
- Tinnitus-Klinik, Bad Arolsen, Germany; University of Witten-Herdecke, Germany
| |
Collapse
|
11
|
Mielczarek M, Michalska J, Polatyńska K, Olszewski J. An Increase in Alpha Band Frequency in Resting State EEG after Electrical Stimulation of the Ear in Tinnitus Patients-A Pilot Study. Front Neurosci 2016; 10:453. [PMID: 27766069 PMCID: PMC5052278 DOI: 10.3389/fnins.2016.00453] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2016] [Accepted: 09/21/2016] [Indexed: 11/22/2022] Open
Abstract
In our clinic invasive transtympanal promontory positive DC stimulations were first used, with a success rate of 42%. However, non-invasive hydrotransmissive negative DC stimulations are now favored, with improvement being obtained in 37.8% directly after the treatment, and 51.3% in a follow up 1 month after treatment. The further improvement after 1 month may be due to neuroplastic changes at central level as a result of altered peripheral input. The aim of the study was to determine how/whether a single electrical stimulation of the ear influences cortical activity, and whether changes observed in tinnitus after electrical stimulation are associated with any changes in cortical activity recorded in EEG. The study included 12 tinnitus patients (F–6, M-6) divided into two groups. Group I comprised six patients with unilateral tinnitus - unilateral, ipsilateral ES was performed. Group II comprised six patients with bilateral tinnitus—bilateral ES was performed. ES was performed using a custom-made apparatus. The active, silver probe—was immersed inside the external ear canal filled with saline. The passive electrode was placed on the forehead. The stimulating frequency was 250 Hz, the intensity ranged from 0.14 to 1.08 mA. The voltage was kept constant at 3 V. The duration of stimulation was 4 min. The EEG recording (Deymed QEST 32) was performed before and after ES. The patients assessed the intensity of tinnitus on the VAS 1-10. Results: In both groups an improvement in VAS was observed—in group I—in five ears (83.3%), in group II—in seven ears (58.3%). In Group I, a significant increase in the upper and lower limit frequency of alpha band was observed in the central temporal and frontal regions following ES. These changes, however, were not correlated with improvement in tinnitus. No significant changes were observed in the beta and theta bands and in group II. Preliminary results of our research reveal a change in cortical activity after electrical stimulations of the ear. However, it remains unclear if it is primary or secondary to peripheral auditory excitation. No similar studies had been found in the literature.
Collapse
Affiliation(s)
- Marzena Mielczarek
- Department of Otolaryngology, Laryngological Oncology, Audiology, and Phoniatrics, Medical University of Lodz Lodz, Poland
| | - Joanna Michalska
- Department of Otolaryngology, Laryngological Oncology, Audiology, and Phoniatrics, Medical University of Lodz Lodz, Poland
| | - Katarzyna Polatyńska
- Department of Neurology, Polish Mother's Memorial Hospital Research Institute Lodz, Poland
| | - Jurek Olszewski
- Department of Otolaryngology, Laryngological Oncology, Audiology, and Phoniatrics, Medical University of Lodz Lodz, Poland
| |
Collapse
|
12
|
Abstract
PURPOSE OF REVIEW Tinnitus, the perception of sound in the absence of a corresponding external acoustic stimulus, is a highly prevalent and frequently severely impairing disorder with worldwide impact. In this article after a short overview about epidemiology and pathophysiology the currently available treatment options will be discussed with specific consideration of the available evidence, their mechanisms of action and their limitations. RECENT FINDINGS During the last decades, advances in neuroimaging methods and the development of animal models have contributed to an increasing understanding of the neuronal correlates of tinnitus and have motivated the development of innovative brain-based treatment approaches for directly targeting the neuronal correlates of tinnitus. A further important development has been the insight that there exist different forms of tinnitus that differ in their pathophysiology and their response to specific treatments. SUMMARY Treatment of tinnitus should be based on a comprehensive diagnosis of etiologic and concomitant aspects of an individual's tinnitus. Already today a large variety of therapeutic interventions are available, which can efficiently reduce tinnitus severity. Several innovative treatment approaches are currently under development.
Collapse
|
13
|
Tinnitus treatment with precise and optimal electric stimulation: opportunities and challenges. Curr Opin Otolaryngol Head Neck Surg 2016. [PMID: 26208122 DOI: 10.1097/moo.0000000000000187] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE OF REVIEW Electric stimulation is a potent means of neuromodulation that has been used to restore hearing and minimize tremor, but its application on tinnitus symptoms has been limited. We examine recent evidence to identify the knowledge gaps in the use of electric stimulation for tinnitus treatment. RECENT FINDINGS Recent studies using electric stimulation to suppress tinnitus in humans are categorized according to their points of attacks. First, noninvasive, direct current stimulation uses an active electrode in the ear canal, tympanic membrane, or temporal scalp. Second, inner ear stimulation uses charge-balanced biphasic stimulation by placing an active electrode on the promontory or round window, or a cochlear implant array in the cochlea. Third, intraneural implants can provide targeted stimulation of specific sites along the auditory pathway. Although these studies demonstrated some success in tinnitus suppression, none established a link between tinnitus suppression efficacy and tinnitus-generating mechanisms. SUMMARY Electric stimulation provides a unique opportunity to suppress tinnitus. Challenges include matching electric stimulation sites and patterns to tinnitus locus and type, meeting the oftentimes-contradictory demands between tinnitus suppression and other indications, such as speech understanding, and justifying the costs and risks of electric stimulation for tinnitus symptoms.
Collapse
|
14
|
Electrical Stimulation of the Ear, Head, Cranial Nerve, or Cortex for the Treatment of Tinnitus: A Scoping Review. Neural Plast 2016; 2016:5130503. [PMID: 27403346 PMCID: PMC4925995 DOI: 10.1155/2016/5130503] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2015] [Revised: 04/22/2016] [Accepted: 05/18/2016] [Indexed: 11/18/2022] Open
Abstract
Tinnitus is defined as the perception of sound in the absence of an external source. It is often associated with hearing loss and is thought to result from abnormal neural activity at some point or points in the auditory pathway, which is incorrectly interpreted by the brain as an actual sound. Neurostimulation therapies therefore, which interfere on some level with that abnormal activity, are a logical approach to treatment. For tinnitus, where the pathological neuronal activity might be associated with auditory and other areas of the brain, interventions using electromagnetic, electrical, or acoustic stimuli separately, or paired electrical and acoustic stimuli, have been proposed as treatments. Neurostimulation therapies should modulate neural activity to deliver a permanent reduction in tinnitus percept by driving the neuroplastic changes necessary to interrupt abnormal levels of oscillatory cortical activity and restore typical levels of activity. This change in activity should alter or interrupt the tinnitus percept (reduction or extinction) making it less bothersome. Here we review developments in therapies involving electrical stimulation of the ear, head, cranial nerve, or cortex in the treatment of tinnitus which demonstrably, or are hypothesised to, interrupt pathological neuronal activity in the cortex associated with tinnitus.
Collapse
|