Islam B, McElwain NL, Li J, Davila MI, Hu Y, Hu K, Bodway JM, Dhekne A, Roy Choudhury R, Hasegawa-Johnson M. Preliminary Technical Validation of LittleBeats™: A Multimodal Sensing Platform to Capture Cardiac Physiology, Motion, and Vocalizations. SENSORS (BASEL, SWITZERLAND) 2024; 24:901. [PMID: 38339617 PMCID: PMC10857055 DOI: 10.3390/s24030901] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 01/19/2024] [Accepted: 01/19/2024] [Indexed: 02/12/2024]
Abstract
Across five studies, we present the preliminary technical validation of an infant-wearable platform, LittleBeats™, that integrates electrocardiogram (ECG), inertial measurement unit (IMU), and audio sensors. Each sensor modality is validated against data from gold-standard equipment using established algorithms and laboratory tasks. Interbeat interval (IBI) data obtained from the LittleBeats™ ECG sensor indicate acceptable mean absolute percent error rates for both adults (Study 1, N = 16) and infants (Study 2, N = 5) across low- and high-challenge sessions and expected patterns of change in respiratory sinus arrythmia (RSA). For automated activity recognition (upright vs. walk vs. glide vs. squat) using accelerometer data from the LittleBeats™ IMU (Study 3, N = 12 adults), performance was good to excellent, with smartphone (industry standard) data outperforming LittleBeats™ by less than 4 percentage points. Speech emotion recognition (Study 4, N = 8 adults) applied to LittleBeats™ versus smartphone audio data indicated a comparable performance, with no significant difference in error rates. On an automatic speech recognition task (Study 5, N = 12 adults), the best performing algorithm yielded relatively low word error rates, although LittleBeats™ (4.16%) versus smartphone (2.73%) error rates were somewhat higher. Together, these validation studies indicate that LittleBeats™ sensors yield a data quality that is largely comparable to those obtained from gold-standard devices and established protocols used in prior research.
Collapse
Affiliation(s)
- Bashima Islam
- Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609, USA
| | - Nancy L. McElwain
- Department of Human Development and Family Studies, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA; (Y.H.); (K.H.); (J.M.B.)
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Jialu Li
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA; (J.L.); (R.R.C.)
| | - Maria I. Davila
- Research Triangle Institute, Research Triangle Park, NC 27709, USA;
| | - Yannan Hu
- Department of Human Development and Family Studies, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA; (Y.H.); (K.H.); (J.M.B.)
| | - Kexin Hu
- Department of Human Development and Family Studies, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA; (Y.H.); (K.H.); (J.M.B.)
| | - Jordan M. Bodway
- Department of Human Development and Family Studies, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA; (Y.H.); (K.H.); (J.M.B.)
| | - Ashutosh Dhekne
- School of Computer Science, Georgia Institute of Technology, Atlanta, GA 30332, USA;
| | - Romit Roy Choudhury
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA; (J.L.); (R.R.C.)
| | - Mark Hasegawa-Johnson
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA; (J.L.); (R.R.C.)
| |
Collapse
|
2
|
Helmstetter S, Matthiesen S. Human Posture Estimation: A Systematic Review on Force-Based Methods-Analyzing the Differences in Required Expertise and Result Benefits for Their Utilization. SENSORS (BASEL, SWITZERLAND) 2023; 23:8997. [PMID: 37960696 PMCID: PMC10647597 DOI: 10.3390/s23218997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 10/27/2023] [Accepted: 10/31/2023] [Indexed: 11/15/2023]
Abstract
Force-based human posture estimation (FPE) provides a valuable alternative when camera-based human motion capturing is impractical. It offers new opportunities for sensor integration in smart products for patient monitoring, ergonomic optimization and sports science. Due to the interdisciplinary research on the topic, an overview of existing methods and the required expertise for their utilization is lacking. This paper presents a systematic review by the PRISMA 2020 review process. In total, 82 studies are selected (59 machine learning (ML)-based and 23 digital human model (DHM)-based posture estimation methods). The ML-based methods use input data from hardware sensors-mostly pressure mapping sensors-and trained ML models for estimating human posture. The ML-based human posture estimation algorithms mostly reach an accuracy above 90%. DHMs, which represent the structure and kinematics of the human body, adjust posture to minimize physical stress. The required expert knowledge for the utilization of these methods and their resulting benefits are analyzed and discussed. DHM-based methods have shown their general applicability without the need for application-specific training but require expertise in human physiology. ML-based methods can be used with less domain-specific expertise, but an application-specific training of these models is necessary.
Collapse
Affiliation(s)
| | - Sven Matthiesen
- Karlsruhe Institute of Technology (KIT), IPEK—Institute of Product Engineering, 76131 Karlsruhe, Germany;
| |
Collapse
|
3
|
Crecan CM, Peștean CP. Inertial Sensor Technologies-Their Role in Equine Gait Analysis, a Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:6301. [PMID: 37514599 PMCID: PMC10386433 DOI: 10.3390/s23146301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 06/20/2023] [Accepted: 07/04/2023] [Indexed: 07/30/2023]
Abstract
Objective gait analysis provides valuable information about the locomotion characteristics of sound and lame horses. Due to their high accuracy and sensitivity, inertial measurement units (IMUs) have gained popularity over objective measurement techniques such as force plates and optical motion capture (OMC) systems. IMUs are wearable sensors that measure acceleration forces and angular velocities, providing the possibility of a non-invasive and continuous monitoring of horse gait during walk, trot, or canter during field conditions. The present narrative review aimed to describe the inertial sensor technologies and summarize their role in equine gait analysis. The literature was searched using general terms related to inertial sensors and their applicability, gait analysis methods, and lameness evaluation. The efficacy and performance of IMU-based methods for the assessment of normal gait, detection of lameness, analysis of horse-rider interaction, as well as the influence of sedative drugs, are discussed and compared with force plate and OMC techniques. The collected evidence indicated that IMU-based sensor systems can monitor and quantify horse locomotion with high accuracy and precision, having comparable or superior performance to objective measurement techniques. IMUs are reliable tools for the evaluation of horse-rider interactions. The observed efficacy and performance of IMU systems in equine gait analysis warrant further research in this population, with special focus on the potential implementation of novel techniques described and validated in humans.
Collapse
Affiliation(s)
- Cristian Mihăiță Crecan
- University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| | - Cosmin Petru Peștean
- University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| |
Collapse
|
4
|
Crecan CM, Morar IA, Lupsan AF, Repciuc CC, Rus MA, Pestean CP. Development of a Novel Approach for Detection of Equine Lameness Based on Inertial Sensors: A Preliminary Study. SENSORS (BASEL, SWITZERLAND) 2022; 22:7082. [PMID: 36146429 PMCID: PMC9505255 DOI: 10.3390/s22187082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 09/07/2022] [Accepted: 09/14/2022] [Indexed: 06/16/2023]
Abstract
Both as an aid for less experienced clinicians and to enhance objectivity and sharp clinical skills in professionals, quantitative technologies currently bring the equine lameness diagnostic closer to evidence-based veterinary medicine. The present paper describes an original, inertial sensor-based wireless device system, the Lameness Detector 0.1, used in ten horses with different lameness degrees in one fore- or hind-leg. By recording the impulses on three axes of the incorporated accelerometer in each leg of the assessed horse, and then processing the data using custom-designed software, the device proved its usefulness in lameness identification and severity scoring. Mean impulse values on the horizontal axis calculated for five consecutive steps above 85, regardless of the leg, indicated the slightest subjectively recognizable lameness, increasing to 130 in severe gait impairment. The range recorded on the same axis (between 61.2 and 67.4) in the sound legs allowed a safe cut-off value of 80 impulses for diagnosing a painful limb. The significance of various comparisons and several correlations highlighted the potential of this simple, affordable, and easy-to-use lameness detector device for further standardization as an aid for veterinarians in diagnosing lameness in horses.
Collapse
Affiliation(s)
- Cristian Mihaita Crecan
- Department of Surgery and Intensive Care, Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| | - Iancu Adrian Morar
- Department of Obstetrics and Reproduction, Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| | - Alexandru Florin Lupsan
- Department of Surgery and Intensive Care, Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| | - Calin Cosmin Repciuc
- Department of Surgery and Intensive Care, Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| | - Mirela Alexandra Rus
- Department of Obstetrics and Reproduction, Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| | - Cosmin Petru Pestean
- Department of Surgery and Intensive Care, Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine Cluj-Napoca, 400372 Cluj-Napoca, Romania
| |
Collapse
|
5
|
Henschke J, Kaplick H, Wochatz M, Engel T. Assessing the validity of inertial measurement units for shoulder kinematics using a commercial sensor-software system: A validation study. Health Sci Rep 2022; 5:e772. [PMID: 35957976 PMCID: PMC9364332 DOI: 10.1002/hsr2.772] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 06/16/2022] [Accepted: 06/21/2022] [Indexed: 11/21/2022] Open
Abstract
Background and Aims Wearable inertial sensors may offer additional kinematic parameters of the shoulder compared to traditional instruments such as goniometers when elaborate and time-consuming data processing procedures are undertaken. However, in clinical practice simple-real time motion analysis is required to improve clinical reasoning. Therefore, the aim was to assess the criterion validity between a portable "off-the-shelf" sensor-software system (IMU) and optical motion (Mocap) for measuring kinematic parameters during active shoulder movements. Methods 24 healthy participants (9 female, 15 male, age 29 ± 4 years, height 177 ± 11 cm, weight 73 ± 14 kg) were included. Range of motion (ROM), total range of motion (TROM), peak and mean angular velocity of both systems were assessed during simple (abduction/adduction, horizontal flexion/horizontal extension, vertical flexion/extension, and external/internal rotation) and complex shoulder movements. Criterion validity was determined using intraclass-correlation coefficients (ICC), root mean square error (RMSE) and Bland and Altmann analysis (bias; upper and lower limits of agreement). Results ROM and TROM analysis revealed inconsistent validity during simple (ICC: 0.040-0.733, RMSE: 9.7°-20.3°, bias: 1.2°-50.7°) and insufficient agreement during complex shoulder movements (ICC: 0.104-0.453, RMSE: 10.1°-23.3°, bias: 1.0°-55.9°). Peak angular velocity (ICC: 0.202-0.865, RMSE: 14.6°/s-26.7°/s, bias: 10.2°/s-29.9°/s) and mean angular velocity (ICC: 0.019-0.786, RMSE:6.1°/s-34.2°/s, bias: 1.6°/s-27.8°/s) were inconsistent. Conclusions The "off-the-shelf" sensor-software system showed overall insufficient agreement with the gold standard. Further development of commercial IMU-software-solutions may increase measurement accuracy and permit their integration into everyday clinical practice.
Collapse
Affiliation(s)
- Jakob Henschke
- Department for sports medicine and sports orthopedics, University Outpatient ClinicUniversity of PotsdamPotsdamGermany
| | - Hannes Kaplick
- Department for sports medicine and sports orthopedics, University Outpatient ClinicUniversity of PotsdamPotsdamGermany
| | - Monique Wochatz
- Department for sports medicine and sports orthopedics, University Outpatient ClinicUniversity of PotsdamPotsdamGermany
| | - Tilman Engel
- Department for sports medicine and sports orthopedics, University Outpatient ClinicUniversity of PotsdamPotsdamGermany
| |
Collapse
|
6
|
Utility of the Novel MediPost Mobile Posturography Device in the Assessment of Patients with a Unilateral Vestibular Disorder. SENSORS 2022; 22:s22062208. [PMID: 35336379 PMCID: PMC8953915 DOI: 10.3390/s22062208] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 03/02/2022] [Accepted: 03/10/2022] [Indexed: 12/28/2022]
Abstract
Balance disorders are a growing problem worldwide. Thus, there is an increasing need to provide an inexpensive and feasible alternative to standard posturographic platforms (SP) used for the assessment of balance and to provide a possible solution for telemonitoring of patients. A novel mobile posturography (MP) MediPost device was developed to address these issues. This prospective study used a Modified Clinical Test of Sensory Interaction on Balance to evaluate healthy individuals and patients with a unilateral vestibular disorder through SP and MP simultaneously. The control group included 65 healthy volunteers, while the study group included 38 patients diagnosed with a unilateral vestibular deficit. The angular velocity values obtained from both methods were compared by intraclass correlation coefficients (ICC) and Bland−Altman plot analysis. Diagnostic capabilities were measured in terms of sensitivity and specificity. The ICC between the two methods for conditions 2−4 was indicative of excellent reliability, with the ICC > 0.9 (p < 0.001), except for Condition 1 (standing stance, eyes open) ICC = 0.685, p < 0.001, which is indicative of moderate reliability. ROC curve analysis of angular velocity for condition 4 represents the most accurate differentiating factor with AUC values of 0.939 for SP and 0.953 for MP. This condition also reported the highest sensitivity, specificity, PPV, and NPV values with 86.4%, 87.7%, 80%, and 90.5% for SP, and 92.1%, 84.6%, 77.8%, and 94.8% for MP, respectively. The newly developed MediPost device has high sensitivity and specificity in distinguishing between healthy individuals and patients with a unilateral vestibular deficit.
Collapse
|
7
|
Telles GF, Ferreira ADS, Junior PMP, Lemos T, Bittencourt JV, Nogueira LAC. Concurrent validity of the inertial sensors for assessment of balance control during quiet standing in patients with chronic low back pain and asymptomatic individuals. J Med Eng Technol 2022; 46:354-362. [PMID: 35243965 DOI: 10.1080/03091902.2022.2043947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The objective was to investigate the concurrent validity of inertial sensors for measuring balance control in patients with chronic low back pain and asymptomatic individuals. Thirty-nine patients with chronic low back and 39 age- and sex-matched asymptomatic individuals were included. Balance control analysis was performed in quiet standing with two inertial sensors positioned at the lumbar region and the sternum and compared to the results of a force plate. The variables analysed with either device were Root Mean Square (RMS), index of smoothness (JERK), trajectory length (PATH) and area (AREA). Spearman's correlation coefficient investigated the correlation. Patients with chronic low back pain showed moderate correlation with the inertial sensor positioned on the lumbar for RMS (rs = 0.59; p < 0.01), PATH (rs = 0.42, p = 0.01) and AREA (rs = 0.59; p < 0.01) and weak correlation with the inertial sensor positioned on the sternum for PATH (rs = 0.36, p = 0.04). The asymptomatic group showed statistically significant correlations for RMS for the lumbar (rs = 0.38; p = 0.03) and sternum inertial sensor (rs = 0.42; p = 0.02). Inertial sensors showed weak to moderate correlations compared to data obtained from a force plate.
Collapse
Affiliation(s)
- Gustavo Felicio Telles
- Rehabilitation Science Postgraduation Progam - Augusto Motta University Center (UNISUAM), Rio de Janeiro, Brazil
| | - Arthur de Sá Ferreira
- Rehabilitation Science Postgraduation Progam - Augusto Motta University Center (UNISUAM), Rio de Janeiro, Brazil
| | - Pedro Manoel Pena Junior
- Rehabilitation Science Postgraduation Progam - Augusto Motta University Center (UNISUAM), Rio de Janeiro, Brazil
| | - Thiago Lemos
- Rehabilitation Science Postgraduation Progam - Augusto Motta University Center (UNISUAM), Rio de Janeiro, Brazil
| | - Juliana Valentim Bittencourt
- Rehabilitation Science Postgraduation Progam - Augusto Motta University Center (UNISUAM), Rio de Janeiro, Brazil
| | - Leandro Alberto Calazans Nogueira
- Rehabilitation Science Postgraduation Progam - Augusto Motta University Center (UNISUAM), Rio de Janeiro, Brazil.,Physiotherapy Department - Federal Institute of Rio de Janeiro (IFRJ), Rio de Janeiro, Brazil
| |
Collapse
|
8
|
Baker N, Gough C, Gordon SJ. Inertial Sensor Reliability and Validity for Static and Dynamic Balance in Healthy Adults: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:5167. [PMID: 34372404 PMCID: PMC8348903 DOI: 10.3390/s21155167] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 07/25/2021] [Accepted: 07/26/2021] [Indexed: 12/15/2022]
Abstract
Compared to laboratory equipment inertial sensors are inexpensive and portable, permitting the measurement of postural sway and balance to be conducted in any setting. This systematic review investigated the inter-sensor and test-retest reliability, and concurrent and discriminant validity to measure static and dynamic balance in healthy adults. Medline, PubMed, Embase, Scopus, CINAHL, and Web of Science were searched to January 2021. Nineteen studies met the inclusion criteria. Meta-analysis was possible for reliability studies only and it was found that inertial sensors are reliable to measure static standing eyes open. A synthesis of the included studies shows moderate to good reliability for dynamic balance. Concurrent validity is moderate for both static and dynamic balance. Sensors discriminate old from young adults by amplitude of mediolateral sway, gait velocity, step length, and turn speed. Fallers are discriminated from non-fallers by sensor measures during walking, stepping, and sit to stand. The accuracy of discrimination is unable to be determined conclusively. Using inertial sensors to measure postural sway in healthy adults provides real-time data collected in the natural environment and enables discrimination between fallers and non-fallers. The ability of inertial sensors to identify differences in postural sway components related to altered performance in clinical tests can inform targeted interventions for the prevention of falls and near falls.
Collapse
Affiliation(s)
- Nicky Baker
- Flinders Digital Health Research Centre, Flinders University, Adelaide, SA 5042, Australia; (C.G.); (S.J.G.)
| | | | | |
Collapse
|
9
|
Gawronska A, Pajor A, Zamyslowska-Szmytke E, Rosiak O, Jozefowicz-Korczynska M. Usefulness of Mobile Devices in the Diagnosis and Rehabilitation of Patients with Dizziness and Balance Disorders: A State of the Art Review. Clin Interv Aging 2020; 15:2397-2406. [PMID: 33376315 PMCID: PMC7764625 DOI: 10.2147/cia.s289861] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Accepted: 12/09/2020] [Indexed: 11/23/2022] Open
Abstract
Objective The gold standard for objective body posture examination is posturography. Body movements are detected through the use of force platforms that assess static and dynamic balance (conventional posturography). In recent years, new technologies like wearable sensors (mobile posturography) have been applied during complex dynamic activities to diagnose and rehabilitate balance disorders. They are used in healthy people, especially in the aging population, for detecting falls in the older adults, in the rehabilitation of different neurological, osteoarticular, and muscular system diseases, and in vestibular disorders. Mobile devices are portable, lightweight, and less expensive than conventional posturography. The vibrotactile system can consist of an accelerometer (linear acceleration measurement), gyroscopes (angular acceleration measurement), and magnetometers (heading measurement, relative to the Earth’s magnetic field). The sensors may be mounted to the trunk (most often in the lumbar region of the spine, and the pelvis), wrists, arms, sternum, feet, or shins. Some static and dynamic clinical tests have been performed with the use of wearable sensors. Smartphones are widely used as a mobile computing platform and to evaluate the results or monitor the patient during the movement and rehabilitation. There are various mobile applications for smartphone-based balance systems. Future research should focus on validating the sensitivity and reliability of mobile device measurements compared to conventional posturography. Conclusion Smartphone based mobile devices are limited to one sensor lumbar level posturography and offer basic clinical evaluation. Single or multi sensor mobile posturography is available from different manufacturers and offers single to multi-level measurements, providing more data and in some instances even performing sophisticated clinical balance tests.
Collapse
Affiliation(s)
- Anna Gawronska
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Anna Pajor
- Department of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Ewa Zamyslowska-Szmytke
- Balance Disorders Unit, Department of Audiology and Phoniatrics, Nofer Institute of Occupational Medicine, Lodz, Poland
| | - Oskar Rosiak
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| | - Magdalena Jozefowicz-Korczynska
- Balance Disorders Unit, Department of Otolaryngology, Medical University of Lodz, The Norbert Barlicki Memorial Teaching Hospital, Lodz, Poland
| |
Collapse
|