1
|
Wilkinson C, Pizzolato M, De Angelis D, Mazzarelli D, D'Apuzzo A, Liu JC, Poppa P, Cattaneo C. Post-mortem to ante-mortem facial image comparison for deceased migrant identification. Int J Legal Med 2024; 138:2691-2706. [PMID: 39150507 PMCID: PMC11490436 DOI: 10.1007/s00414-024-03286-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 07/01/2024] [Indexed: 08/17/2024]
Abstract
The identification of deceased migrants is a global challenge that is exacerbated by migration distance, post-mortem conditions, access to ante-mortem data for comparison, inconsistent international procedures and lack of communication between arrival and origin countries. Due to low technology requirements, fast speed analysis and ease of transferring digital data, facial image comparison is particularly beneficial in those contexts, especially in challenging scenarios when this may be the only initial ante-mortem data available to identify the deceased. The Facial Identification Scientific Working Group (FISWG) professional guidelines for facial image comparison were developed for living facial appearance, and, therefore, a tailored protocol for the application of post-mortem to ante-mortem facial image comparison was proposed and evaluated in this research. The protocol was investigated via an inter-observer and an accuracy study, using 29 forensic cases (2001-2020) from the University of Milan, provided by the Laboratory of Forensic Anthropology and Odontology. In order to replicate a migrant identification scenario, each post-mortem subject was compared to all 29 ante-mortem targets (841 comparisons). The protocol guided the practitioner through stages of facial image comparison, from broad (phase 1) to more detailed (phase 3), eventually leading to a decision of 'exclusion' or 'potential match' for each post-mortem to ante-mortem case (phase 4). In phase 4, a support scale was also utilised to indicate the level of confidence in a potential match. Each post-mortem subject could be recorded with multiple potential matches. The protocol proved to be useful guide for facial image comparison, especially for less experienced practitioners and the inter-observer study suggested good reproducibility. The majority (82-96%) of ante-mortem subjects were excluded at the first stage of the protocol, and 71 full post-mortem to ante-mortem facial image comparisons were carried out. On average, two or three potential matches were recorded for each post-mortem subject. The overall accuracy rate was 85%, with the majority (79%) of ante-mortem non-targets correctly excluded from the identification process. An increased number and quality of available ante-mortem images produced more successful matches with higher levels of support. All potential matches involving non-targets received low levels of support, and for 73% of the post-mortem subjects, the ante-mortem target was the only recorded potential match. However, two ante-mortem targets were incorrectly excluded (one at the first stage of the protocol) and therefore changes to the protocol were implemented to mitigate these errors. A full protocol and a practical recording chart for practitioner use is included with this paper.
Collapse
|
2
|
Cappella A, De Angelis D, Mazzarelli D, Vitale A, Caccia G, Fracasso T, Cattaneo C. Rediscovering the value of images in supporting personal identification of missing migrants. Leg Med (Tokyo) 2021; 54:101985. [PMID: 34753067 DOI: 10.1016/j.legalmed.2021.101985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Accepted: 10/23/2021] [Indexed: 10/19/2022]
Abstract
The crisis concerning the identification of dead migrants is forcing forensic scientists to deal with the unavailability of classical antemortem (AM) data such as radiological information and DNA. However many times there is abundant AM photographic data of which the availability and quality is underestimated. Independently of when facial image comparison can be used as a valid identification method, description of the unexpected quality and quantity of images in the scenario of unidentified migrant decedents is given in this observational study. It focuses on the overall characteristics of the AM images available for a group of 74 missing migrants related to the disaster of October 3rd, 2013. 394 images were collected: an average of 6 for each missing person. 18% are original pictures, 47.5% scans of original images, 9.9% scans of printed images while 9.4% downloaded from social networks such as Facebook. 42.7% of images resulted in focus. Among all the images, about the 10% has been used in the personal identification process to ascertain the identity of 22 persons, because of the visibility of identifying details (facial, dental and body features). The importance of such a finding should not be diminished by its simplicity. Today, those involved in collecting AM information from relatives of dead migrants are underestimating the possible presence of images, even in sub-Saharan populations, where, contrary to belief and data, technology, though simple, is available and images may turn out to be abundant and useful (and at times the only resort) for identification.
Collapse
Affiliation(s)
- Annalisa Cappella
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Italy; U.O. Laboratorio di Morfologia Umana Applicata, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
| | - Danilo De Angelis
- Labanof (Laboratorio di Antropologia e Odontologia Forense), Sezione di Medicina Legale, Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Italy
| | - Debora Mazzarelli
- Labanof (Laboratorio di Antropologia e Odontologia Forense), Sezione di Medicina Legale, Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Italy; Fondazione Isacchi Samaja ONLUS, Milan, Italy
| | - Albarita Vitale
- Labanof (Laboratorio di Antropologia e Odontologia Forense), Sezione di Medicina Legale, Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Italy
| | - Giulia Caccia
- Labanof (Laboratorio di Antropologia e Odontologia Forense), Sezione di Medicina Legale, Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Italy
| | - Tony Fracasso
- University Center of Legal Medicine, Geneva University Hospital, Geneva, Switzerland
| | - Cristina Cattaneo
- Labanof (Laboratorio di Antropologia e Odontologia Forense), Sezione di Medicina Legale, Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Italy
| |
Collapse
|
3
|
Donato L, Cecchi R, Goldoni M, Ubelaker DH. Photogrammetry vs CT Scan: Evaluation of Accuracy of a Low-Cost Three-Dimensional Acquisition Method for Forensic Facial Approximation. J Forensic Sci 2020; 65:1260-1265. [PMID: 32216148 DOI: 10.1111/1556-4029.14319] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2019] [Revised: 02/28/2020] [Accepted: 03/03/2020] [Indexed: 11/26/2022]
Abstract
Photogrammetry is a three-dimensional acquisition method potentially applicable to the forensic field. This possibility requires the verification of its accuracy. In this study, 3D volumes of skulls are generated to compare the photogrammetry versus the CT scan. In order to provide eligible material to the photogrammetric software, photographs were captured at a distance of 30 cm from the skull placed on a support 1 m in height and illuminated with diffused laboratory ceiling artificial light. A Nikon Coolpix P7100 camera was used. Photographs capture common elements with the previous and the next photograph so as to allow the photogrammetric software to recognize these common points between photographs and create a 3D puzzle. The Zephyr Lite (3DFlow©) software was employed to register the 3D volume. CT-based skulls are taken as a metric reference. The photogrammetry-based skulls are then enlarged according to the measurements of some landmarks or Zygion and Zygion, the distance between end of nasal and base of nasal pyramid for frontal projection, and minimum breadth of the mandibular ramus for the right lateral projection. The accuracy of the photogrammetry is compared to that of the CT scan by measuring the 3D volumes of the skulls studied. Specific landmarks are used as reference points for the measures in both frontal and lateral views. Bland-Altman graph shows homogeneity. The mean difference (1.28 mm) indicates that the measurements taken on the photogrammetry-based skull tend to slightly overestimate compared with the measurements taken on the CT-based skull.
Collapse
Affiliation(s)
- Laura Donato
- Department of Medicine and Surgery, Section of Forensic Pathology, University of Parma, Via A. Gramsci 14, 43126, Parma, Italy
| | - Rossana Cecchi
- Department of Medicine and Surgery, Section of Forensic Pathology, University of Parma, Via A. Gramsci 14, 43126, Parma, Italy
| | - Matteo Goldoni
- Department of Medicine and Surgery, University of Parma, Via A. Gramsci 14, 43126, Parma, Italy
| | - Douglas H Ubelaker
- Anthropology Department, NMNH, Smithsonian Institution, MRC 112, Washington, DC
| |
Collapse
|
4
|
Gibelli D, Dolci C, Cappella A, Sforza C. Reliability of optical devices for three-dimensional facial anatomy description: a systematic review and meta-analysis. Int J Oral Maxillofac Surg 2019; 49:1092-1106. [PMID: 31786104 DOI: 10.1016/j.ijom.2019.10.019] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Revised: 08/02/2019] [Accepted: 10/30/2019] [Indexed: 01/19/2023]
Abstract
The use of three-dimensional (3D) optical instruments to measure soft tissue facial characteristics is increasing, but systematic assessments of their reliability, practical use in research and clinics, outcome measurements, and advantages and limitations are not fully established. Therefore, a review of the current literature was performed on the reliability of facial anthropometric measurements obtained by 3D optical facial reproductions as compared to conventional anthropometry or other optical devices. The systematic literature search was conducted in electronic databases following the PRISMA guidelines (PROSPERO registration: CRD42018085473). Overall, 815 studies were identified, with 27 final papers included. Two meta-analyses were conducted. Tested devices included conventional cameras, laser scanning, stereophotogrammetry, and structured light. Studies measured living people or inanimate objects. Overall, the optical devices were considered reliable for the measurement of linear distances. Some caution is needed for surface assessments. All instruments are suitable for the analysis of inanimate objects, but fast scan devices should be preferred for living subjects to avoid motion artefacts in the orbital and nasolabial areas. Prior facial landmarking is suggested to improve measurement accuracy. Practical needs and economic means should direct the choice of the most appropriate instrument. Considering the increasing interest in surface-to-surface measurements, fast scan devices should be preferred, and dedicated protocols devised.
Collapse
Affiliation(s)
- D Gibelli
- Functional Anatomy Research Centre (FARC), Laboratorio di Anatomia Funzionale dell'Apparato Stomatognatico (LAFAS), Department of Biomedical Sciences for Health, Faculty of Medicine and Surgery, Università degli Studi di Milano, Milano, Italy
| | - C Dolci
- Functional Anatomy Research Centre (FARC), Laboratorio di Anatomia Funzionale dell'Apparato Stomatognatico (LAFAS), Department of Biomedical Sciences for Health, Faculty of Medicine and Surgery, Università degli Studi di Milano, Milano, Italy
| | - A Cappella
- Functional Anatomy Research Centre (FARC), Laboratorio di Anatomia Funzionale dell'Apparato Stomatognatico (LAFAS), Department of Biomedical Sciences for Health, Faculty of Medicine and Surgery, Università degli Studi di Milano, Milano, Italy
| | - C Sforza
- Functional Anatomy Research Centre (FARC), Laboratorio di Anatomia Funzionale dell'Apparato Stomatognatico (LAFAS), Department of Biomedical Sciences for Health, Faculty of Medicine and Surgery, Università degli Studi di Milano, Milano, Italy.
| |
Collapse
|
5
|
Gibelli D, Pucciarelli V, Caplova Z, Cappella A, Dolci C, Cattaneo C, Sforza C. Validation of a low-cost laser scanner device for the assessment of three-dimensional facial anatomy in living subjects. J Craniomaxillofac Surg 2018; 46:1493-1499. [DOI: 10.1016/j.jcms.2018.06.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 05/28/2018] [Accepted: 06/05/2018] [Indexed: 11/25/2022] Open
|