1
|
Qian X, Huang C, Li R, Song BJ, Tchelepi H, Shung KK, Chen S, Humayun MS, Zhou Q. Super-Resolution Ultrasound Localization Microscopy for Visualization of the Ocular Blood Flow. IEEE Trans Biomed Eng 2022; 69:1585-1594. [PMID: 34652993 PMCID: PMC9113921 DOI: 10.1109/tbme.2021.3120368] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The ocular vascular system plays an important role in preserving the visual function. Alterations in either anatomy or hemodynamics of the eye may have adverse effects on vision. Thus, an imaging approach that can monitor alterations of ocular blood flow of the deep eye vasculature ranging from capillary-level vessels to large supporting vessels would be advantageous for detection of early stage retinal and optic nerve diseases. METHODS We propose a super-resolution ultrasound localization microscopy (ULM) technique that can assess both the microvessel and flow velocity of the deep eye with high resolution. Ultrafast plane wave imaging was acquired using an L22-14v linear array on a high frequency Verasonics Vantage system. A robust microbubble localization and tracking technique was applied to reconstruct ULM images. The experiment was first performed on pre-designed flow phantoms in vitro and then tested on a New Zealand white rabbit eye in vivo calibrated to various intraocular pressures (IOP) - 10 mmHg, 30 mmHg and 50 mmHg. RESULTS We demonstrated that retinal/choroidal vessels, central retinal artery, posterior ciliary artery, and vortex vein were all visible at high resolution. In addition, reduction of vascular density and flow velocity were observed with elevated IOPs. CONCLUSION These results indicate that super-resolution ULM is able to image the deep ocular tissue while maintaining high resolution that is comparable with optical coherence tomography angiography. SIGNIFICANCE Capability to detect subtle changes of blood flow may be clinically important in detecting and monitoring eye diseases such as glaucoma.
Collapse
|
2
|
Li TT, Shao GB, Jiang YL, Wang JX, Zhou XR, Ren M, Li LQ. Ocular surface heat effects on ocular hemodynamics detected by real-time measuring device. Int J Ophthalmol 2018; 11:1902-1908. [PMID: 30588420 DOI: 10.18240/ijo.2018.12.04] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Accepted: 10/15/2018] [Indexed: 11/23/2022] Open
Abstract
AIM To investigate the ocular hemodynamic effects of applying a hot compress to the eye. METHODS The right eyes of five New Zealand white rabbits, both male and female, were hot-compressed for 18min. An independently designed novel ocular contact-type temperature measuring device was used to measure the ocular surface temperature before and after the heating. Relevant retrobulbar hemodynamic parameters such as peak systolic velocity (PSV), end diastolic velocity (EDV), and resistance index (RI) of each of the central retinal artery (CRA), long posterior ciliary artery (LPCA), and ophthalmic artery (OA), as well as the mean velocity (Vm) of the central retinal vein (CRV), were measured using a color Doppler flow imaging (CDFI) technique and expressed as mean values with standard deviation (mean±SD). A statistical analysis was conducted based on a paired t-test and the Wilcoxon signed-rank test. RESULTS The employed real-time temperature measuring device was able to accurately measure ocular surface temperature during the hot-compress process. The temperature increased after the hot compress was applied. Analysis showed that the PSV and EDV values of the CRA and LPCA significantly increased after the application of the hot compress, as did the Vm of the CRV. There were no significant changes in the EDV of the OA nor the RI of each artery. CONCLUSION This experiment, which is the first of its kind, confirms that the retrobulbar blood flow velocities can increase upon heating the ocular surface. This simple method may be useful in the future.
Collapse
Affiliation(s)
- Ting-Ting Li
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine (originally named "Shanghai First People's Hospital"), Shanghai 200080, China.,Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai 200080, China.,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai 200080, China.,Department of Ophthalmology, the Second Affiliated Hospital of Harbin Medical University, Harbin 150000, Heilongjiang Province, China
| | - Guang-Bin Shao
- Key Laboratory of Micro-systems and Microstructures Manufacturing of Ministry of Education, Harbin Institute of Technology, Harbin 150001, Heilongjiang Province, China
| | - Yu-Long Jiang
- Key Laboratory of Micro-systems and Microstructures Manufacturing of Ministry of Education, Harbin Institute of Technology, Harbin 150001, Heilongjiang Province, China
| | - Jing-Xuan Wang
- Key Laboratory of Micro-systems and Microstructures Manufacturing of Ministry of Education, Harbin Institute of Technology, Harbin 150001, Heilongjiang Province, China
| | - Xin-Rong Zhou
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine (originally named "Shanghai First People's Hospital"), Shanghai 200080, China.,Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai 200080, China.,Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai 200080, China.,Department of Ophthalmology, the Second Affiliated Hospital of Harbin Medical University, Harbin 150000, Heilongjiang Province, China
| | - Min Ren
- Department of Ultrasound, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai 201204, China
| | - Long-Qiu Li
- Key Laboratory of Micro-systems and Microstructures Manufacturing of Ministry of Education, Harbin Institute of Technology, Harbin 150001, Heilongjiang Province, China
| |
Collapse
|
3
|
de Moraes W, Ferreira TAC, Somma AT, Cubas ZS, Moore BA, Montiani-Ferreira F. Doppler ultrasonography of the pectinis oculi artery in harpy eagles ( Harpia harpyja). Open Vet J 2017; 7:70-74. [PMID: 28540254 PMCID: PMC5443402 DOI: 10.4314/ovj.v7i1.11] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Accepted: 03/21/2017] [Indexed: 12/20/2022] Open
Abstract
Twenty harpy eagles (Harpia harpyja) without systemic or ocular
diseases were examined to measure blood velocity parameters of the pectinis
oculi artery using Doppler ultrasonography. Pectinate artery resistive
index (RI) and pulsatility index (PI) were investigated using ocular Doppler
ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and
0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s
pectinis oculi artery compared with the American pekin ducks one
and other tissue suggest indeed a high metabolic activity in pecten
oculi and corroborates the hypothesis of a nutritional function and/or
intraocular pressure regulation.
Collapse
Affiliation(s)
- Wanderlei de Moraes
- Universidade Federal do Paraná (UFPR), Departamento de Medicina Veterinária, Rua dos Funcionários, 1540, 80035-050, Curitiba - PR, Brazil.,ITAIPU Binacional, Diretoria de Coordenação, Departamento de Áreas Protegidas, Refúgio Biológico Bela Vista, Rua Teresina, 62, Vila C,85870-280, Foz do Iguaçu - PR, Brazil
| | - Thiago A C Ferreira
- Universidade Federal do Paraná (UFPR), Departamento de Medicina Veterinária, Rua dos Funcionários, 1540, 80035-050, Curitiba - PR, Brazil
| | - André T Somma
- Universidade Federal do Paraná (UFPR), Departamento de Medicina Veterinária, Rua dos Funcionários, 1540, 80035-050, Curitiba - PR, Brazil
| | - Zalmir S Cubas
- ITAIPU Binacional, Diretoria de Coordenação, Departamento de Áreas Protegidas, Refúgio Biológico Bela Vista, Rua Teresina, 62, Vila C,85870-280, Foz do Iguaçu - PR, Brazil
| | - Bret A Moore
- University of California-Davis, School of Veterinary Medicine, Ophthalmology, 1 Garrod Drive, Davis, CA, 95695, USA
| | - Fabiano Montiani-Ferreira
- Universidade Federal do Paraná (UFPR), Departamento de Medicina Veterinária, Rua dos Funcionários, 1540, 80035-050, Curitiba - PR, Brazil
| |
Collapse
|
4
|
Microvascular endothelial function and severity of primary open angle glaucoma. Eye (Lond) 2016; 30:1579-1587. [PMID: 27540832 DOI: 10.1038/eye.2016.185] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Accepted: 06/26/2016] [Indexed: 11/09/2022] Open
Abstract
PurposeThe role of microvascular endothelial dysfunction on severity of primary open angle glaucoma (POAG) was investigated in this study.Patients and methodsA prospective cohort study was conducted. One hundred and fourteen ethnically Malay patients (114 eyes) with POAG treated at the eye clinic of Hospital University Sains Malaysia between April 2012 and December 2014 were recruited. Patients aged between 40 and 80 years with two consecutive reliable and reproducible Humphrey visual field 24-2 analyses were selected. Patients who were diagnosed with any other type of glaucoma, previous glaucoma-filtering surgery, or other surgeries except uncomplicated cataract and pterygium surgery were excluded. Humphrey visual field analysis 24-2 was used to stratify the severity of glaucoma using Advanced Glaucoma Intervention Study (AGIS) score at the time of recruitment. Microvascular endothelial function was assessed using Laser Doppler fluximetry and iontophoresis. Iontophoresis process with acetylcholine (ACh) and sodium nitroprusside (SNP) was used to measure microvascular endothelium-dependent and -independent vasodilatation, respectively.ResultsBased on the AGIS score, 55 patients showed mild glaucoma, with 29 moderate and 30 severe. There was statistically significant difference in microvascular endothelial function (ACh% and AChmax) between mild and moderate POAG cases (P=0.023) and between mild and severe POAG cases (P<0.001). There was negative correlation between microvascular endothelial function and severity of POAG (r=-0.457, P<0.001).ConclusionMicrovascular endothelial dysfunction may have a role in influencing the severity of POAG in Malay patients.
Collapse
|
5
|
Sun J, Kwan RLC, Zheng Y, Cheing GLY. Effects of pulsed electromagnetic fields on peripheral blood circulation in people with diabetes: A randomized controlled trial. Bioelectromagnetics 2016; 37:290-7. [PMID: 27227568 DOI: 10.1002/bem.21983] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Accepted: 05/10/2016] [Indexed: 11/10/2022]
Abstract
Cutaneous blood flow provides nourishment that plays an essential role in maintaining skin health. We examined the effects of pulsed electromagnetic fields (PEMFs) on cutaneous circulation of dorsal feet. Twenty-two patients with diabetes mellitus (DM) and 21 healthy control subjects were randomly allocated to receive either PEMFs or sham PEMFs (0.5 mT, 12 Hz, 30 min). Blood flow velocity and diameter of the small vein were examined by using ultrasound biomicroscopy; also, microcirculation at skin over the base of the 1st metatarsal bone (Flux1) and distal 1st phalange (Flux2) was measured by laser Doppler flowmetry before and after intervention. Results indicated that PEMFs produced significantly greater changes in blood flow velocity of the smallest observable vein than did sham PEMFs (both P < 0.05) in both types of subjects. However, no significant difference was found in changes of vein diameter, nor in Flux1 and Flux2, between PEMFs and sham PEMFs groups in subjects with or without DM. We hypothesized that PEMFs would increase blood flow velocity of the smallest observable vein in people with or without DM. Bioelectromagnetics. 37:290-297, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Jiahui Sun
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China
| | - Rachel Lai-Chu Kwan
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China
| | - Yongping Zheng
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China
| | - Gladys Lai-Ying Cheing
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, China
| |
Collapse
|
6
|
Ferreira TAC, Turner Giannico A, Montiani-Ferreira F. Hemodynamics of the pectinis oculi artery in American pekin ducks (Anas platyrhynchos domestica). Vet Ophthalmol 2015; 19:409-13. [PMID: 26398920 DOI: 10.1111/vop.12316] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To measure blood velocity parameters of the main detectable branch of the pectinis oculi artery and compare with values found in other arteries in other species to form a hypothesis of the function of the pecten oculi in birds. METHODS Eleven American pekin ducks (Anas platyrhynchos domestica) without ocular diseases were examined with ocular Doppler ultrasonography. The pectinate artery resistive index (RI) and pulsatility index (PI) were calculated. RESULTS The mean of RI and PI values resulted, respectively, in: left eye (0.43 ± 0.07; 0.58 ± 0.13), right eye (0.37 ± 0.09; 0.47 ± 0.14), and both eyes (0.40 ± 0.08; 0.53 ± 0.14). DISCUSSION The low RI and PI values found in the main branch of the pectinis oculi artery compared with other arteries in other tissues suggest a high metabolic activity in the pecten oculi, and it could indicate a nutritional function and/or intraocular pressure regulation.
Collapse
Affiliation(s)
- Thiago Alegre C Ferreira
- Programa de Pós-Graduação em Ciências Veterinárias, Federal University of Paraná, Curitiba, Brazil
| | - Amália Turner Giannico
- Programa de Pós-Graduação em Ciências Veterinárias, Federal University of Paraná, Curitiba, Brazil
| | - Fabiano Montiani-Ferreira
- Veterinary Medicine Department, Federal University of Paraná, Rua dos Funcionários, 1540, 80035-050, Curitiba-PR, Brazil.
| |
Collapse
|
7
|
Barbur JL, Connolly DM. Effects of hypoxia on color vision with emphasis on the mesopic range. EXPERT REVIEW OF OPHTHALMOLOGY 2014. [DOI: 10.1586/eop.11.32] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
8
|
Kang SJ, Zhang Q, Patel SR, Berezovsky D, Yang H, Wang Y, Grossniklaus HE. In vivo high-frequency contrast-enhanced ultrasonography of choroidal melanoma in rabbits: imaging features and histopathologic correlations. Br J Ophthalmol 2013; 97:929-33. [PMID: 23645822 DOI: 10.1136/bjophthalmol-2013-303343] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
PURPOSE To evaluate the use of in vivo imaging of rabbit model of choroidal melanoma using high-frequency contrast-enhanced ultrasound (HF-CE-US) with two-dimensional (2D) or three-dimensional (3D) modes and to correlate the sonographic findings with histopathologic characteristics. METHODS Five New Zealand white rabbits, which were immunosuppressed with daily cyclosporin A (CsA), were inoculated into their right eyes with aliquots of 1.5×10(6)/50 μl of 92.1 human uveal melanoma cells cultured in RPMI. At week 4, the tumour-bearing eyes were imaged using high-frequency ultrasound (HF-US) with microbubble contrast agent to determine the 2D tumour size and relative blood volume and by 3D mode to determine tumour volume. Histologic tumour burden was quantified in enucleated eyes by ImageJ software, and mean vascular density (MVD) was determined by counting vascular channels in periodic acid Schiff (PAS) without haematoxylin sections. RESULTS Using HF-CE-US, melanomas were visualised as relatively hyperechoic regions in the images. The correlation coefficients of sonographic size and volume compared with histologic area were 0.72 and 0.70, respectively. The sonographic tumour relative blood volume correlated with the histologic tumour vascularity (r(2)=0.92, p=0.04). CONCLUSIONS There is a positive correlation between in vivo sonographic tumour volume/size and histologic tumour size in our rabbit choroidal melanoma model. HF-CE-US corresponds to MVD and blood volume.
Collapse
Affiliation(s)
- Shin J Kang
- Department of Ophthalmology, Emory University School of Medicine, Atlanta, Georgia, USA
| | | | | | | | | | | | | |
Collapse
|
9
|
Abdallah WF, Patel H, Grant EG, Diniz B, Chader GJ, Humayun MS. Evaluation of ultrasound-assisted thrombolysis using custom liposomes in a model of retinal vein occlusion. Invest Ophthalmol Vis Sci 2012; 53:6920-7. [PMID: 22969076 DOI: 10.1167/iovs.12-10389] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To study the potential efficacy of ultrasound (US) assisted by custom liposome (CLP) destruction as an innovative thrombolytic tool for the treatment of retinal vein occlusion (RVO). METHODS Experimental RVO was induced in the right eyes of 40 rabbits using laser photothrombosis; the US experiment took place 48 hours later. Rabbits were randomly divided into four equal groups: US+CLP group, US+saline group, CLP+sham US group, and no treatment group. The latter three groups acted as controls. Fundus fluorescein angiography and Doppler US were used to evaluate retinal blood flow. RESULTS CLP-assisted US thrombolysis resulted in restoration of flow in seven rabbits (70%). None of the control groups showed significant restoration of retinal venous blood flow. CONCLUSIONS US-assisted thrombolysis using liposomes resulted in a statistically significant reperfusion of retinal vessels in the rabbit experimental model of RVO. This approach might be promising in the treatment of RVO in humans. Further studies are needed to evaluate this approach in patients with RVO. Ultrasound assisted thrombolysis can be an innovative tool in management of retinal vein occlusion.
Collapse
|
10
|
Wang X, Wu Q. Normal corneal thickness measurements in pigmented rabbits using spectral-domain anterior segment optical coherence tomography. Vet Ophthalmol 2012; 16:130-4. [PMID: 22672083 DOI: 10.1111/j.1463-5224.2012.01041.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To document the thickness of the central cornea in pigmented rabbits using spectral-domain anterior segment optical coherence tomography (AS-OCT). ANIMALS STUDIED Seventeen pigmented rabbits (6 male, 11 female, both eyes) were involved in this study. PROCEDURES Thirty-four eyes from healthy pigmented rabbits underwent a complete ophthalmologic examination, including AS-OCT. Eight radial scans, 6 mm in length and centered on the cornea, were obtained using the AS-OCT. Corneal thickness was automatically calculated using pachymetry software. Measurements were displayed as the mean and standard deviation for each of the 17 regions defined by the software. The regions were the center (1 mm radius, area a), the inner ring (2.5 mm radius, area b), the outer ring (3 mm radius, area c), and the eight radial scan lines in eight directions (Superior (1), SN (2), Nasal (3), IN (4), Inferior (5), IT (6), Temporal (7), ST (8)) with an angle of 45° between each consecutive scan line (a, b 1-8, c 1-8). RESULTS There was no statistically significance difference in corneal thickness between gender, eye, and the eight directions (P = 0.804, P > 0.05, P > 0.05). There was a statistical difference between the thickness in areas a, b, and c (P < 0.05). The corneal thickness increased gradually from the center to the periphery of the 6 mm measured. The center corneal thickness was 387 ± 19.8 μm for OD and 384 ± 20.2 μm for OS. The corneal thicknesses of the thinnest point of the right eyes (OD) and the left eyes (OS) were 376 ± 20.2 and 370 ± 16.8 μm, respectively. There was positive correlation between the thinnest point and area a in both the right eyes (r = 0.892, P < 0.001) and the left eyes (r = 0.832, P < 0.001). CONCLUSIONS This is the first documentation of the rabbit corneal thickness in vivo using the spectral-domain AS-OCT. Pigmented rabbit corneas were almost 150 μm thinner than human corneal values. Gender and eye were not associated with any statistical differences in central corneal thickness in this study.
Collapse
Affiliation(s)
- Xiaogang Wang
- Department of Ophthalmology, Affiliated Sixth People's Hospital Shanghai Jiao Tong University, Shanghai, China.
| | | |
Collapse
|
11
|
Toni MC, Meirelles AÉWB, Gava FN, Camacho AA, Laus JL, Canola JC. Rabbits’ eye globe sonographic biometry. Vet Ophthalmol 2010; 13:384-6. [DOI: 10.1111/j.1463-5224.2010.00831.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|