1
|
Surowiec I, Scholz J. Capacitance sensors in cell-based bioprocesses: online monitoring of biomass and more. Curr Opin Biotechnol 2023; 83:102979. [PMID: 37619528 DOI: 10.1016/j.copbio.2023.102979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 07/10/2023] [Accepted: 07/10/2023] [Indexed: 08/26/2023]
Abstract
Biocapacitance measurement has emerged as a widely used technique for monitoring bioprocesses that involve living cells. Over time, hardware and software developments have enabled this method to move from food towards biopharma industries for improved characterisation, monitoring and control of the bioprocess, even in strictly regulated production environments. In alignment with the general trends in biopharma towards new modalities such as virus-based and cell-based therapies, biocapacitance measurement is entering this area and provides new opportunities for process development and control. Based on the recent progress, the authors strongly believe that even though biocapacitance measurement is a mature, established technology for online biomass monitoring, the nearest future will bring its new and exciting developments and applications that will enhance bioprocess understanding and bring new solutions for enhanced process understanding, monitoring and control.
Collapse
|
2
|
Lemke J, Söldner R, Austerjost J. Online deployment of an O-PLS model for dielectric spectroscopy-based inline monitoring of viable cell concentrations in Chinese hamster ovary cell perfusion cultivations. Eng Life Sci 2023; 23:e2200053. [PMID: 37275212 PMCID: PMC10235861 DOI: 10.1002/elsc.202200053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 02/17/2023] [Accepted: 04/11/2023] [Indexed: 06/07/2023] Open
Abstract
Viable cell concentration (VCC) is an essential parameter that is required to support the efficient cultivation of mammalian cells. Although commonly determined using at-line or off-line analytics, in-line capacitance measurements represent a suitable alternative method for the determination of VCC. In addition, these latter efforts are complimentary with the Food and Drug Administration's initiative for process analytical technologies (PATs). However, current applications for online determination of the VCC often rely on single frequency measurements and corresponding linear regression models. It has been reported that this may be insufficient for application at all stages of a mammalian cell culture processes due to changes in multiple cell parameters over time. Alternatively, dielectric spectroscopy, measuring capacitance at multiple frequencies, in combination with multivariate mathematical models, has proven to be more robust. However, this has only been applied for retrospective data analysis. Here, we present the implementation of an O-PLS model for the online processing of multifrequency capacitance signals and the on-the-fly integration of the models' VCC results into a supervisory control and data acquisition (SCADA) system commonly used for cultivation observation and control. This system was evaluated using a Chinese hamster ovary (CHO) cell perfusion process.
Collapse
Affiliation(s)
- Johannes Lemke
- Corporate ResearchSartorius Stedim Biotech GmbHGöttingenGermany
| | - Robert Söldner
- Corporate ResearchSartorius Stedim Biotech GmbHGöttingenGermany
| | | |
Collapse
|
3
|
Bergin A, Carvell J, Butler M. Applications of bio-capacitance to cell culture manufacturing. Biotechnol Adv 2022; 61:108048. [DOI: 10.1016/j.biotechadv.2022.108048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 08/05/2022] [Accepted: 09/30/2022] [Indexed: 11/16/2022]
|
4
|
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes. Processes (Basel) 2022. [DOI: 10.3390/pr10020189] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
The growing biopharmaceutical industry has reached a level of maturity that allows for the monitoring of numerous key variables for both process characterization and outcome predictions. Sensors were historically used in order to maintain an optimal environment within the reactor to optimize process performance. However, technological innovation has pushed towards on-line in situ continuous monitoring of quality attributes that could previously only be estimated off-line. These new sensing technologies when coupled with software models have shown promise for unique fingerprinting, smart process control, outcome improvement, and prediction. All this can be done without requiring invasive sampling or intervention on the system. In this paper, the state-of-the-art sensing technologies and their applications in the context of cell culture monitoring are reviewed with emphasis on the coming push towards industry 4.0 and smart manufacturing within the biopharmaceutical sector. Additionally, perspectives as to how this can be leveraged to improve both understanding and outcomes of cell culture processes are discussed.
Collapse
|
5
|
Gillespie C, Wasalathanthri DP, Ritz DB, Zhou G, Davis KA, Wucherpfennig T, Hazelwood N. Systematic assessment of process analytical technologies for biologics. Biotechnol Bioeng 2021; 119:423-434. [PMID: 34778948 DOI: 10.1002/bit.27990] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 10/18/2021] [Accepted: 11/01/2021] [Indexed: 12/22/2022]
Abstract
The application of process analytical technology (PAT) for biotherapeutic development and manufacturing has been employed owing to technological, economic, and regulatory advantages across the industry. Typically, chromatographic, spectroscopic, and/or mass spectrometric sensors are integrated into upstream and downstream unit operations in in-line, on-line, or at-line fashion to enable real-time monitoring and control of the process. Despite the widespread utility of PAT technologies at various unit operations of the bioprocess, a holistic business value assessment of PAT has not been well addressed in biologics. Thus, in this study, we evaluated PAT technologies based on predefined criteria for their technological attributes such as enablement of better process understanding, control, and high-throughput capabilities; as well as for business attributes such as simplicity of implementation, lead time, and cost reduction. The study involved an industry-wide survey, where input from subject matter industry experts on various PAT tools were collected, assessed, and ranked. The survey results demonstrated on-line liquid Chromatography (LC), in-line Raman, and gas analysis techniques are of high business value especially at the production bioreactor unit operation of upstream processing. In-line variable path-length UV/VIS measurements (VPE), on-line LC, multiangle light scattering (MALS), and automated sampling are of high business value in Protein A purification and polishing steps of the downstream process. We also provide insights, based on our experience in clinical and commercial manufacturing of biologics, into the development and implementation of some of the PAT tools. The results presented in this study are intended to be helpful for the current practitioners of PAT as well as those new to the field to gauge, prioritize and steer their projects for success.
Collapse
Affiliation(s)
| | | | - Diana B Ritz
- GlaxoSmithKline, King of Prussia, Pennsylvania, USA
| | - George Zhou
- Merck & Co., Inc., Kenilworth, New Jersey, USA
| | | | | | | |
Collapse
|
6
|
Metze S, Blioch S, Matuszczyk J, Greller G, Grimm C, Scholz J, Hoehse M. Multivariate data analysis of capacitance frequency scanning for online monitoring of viable cell concentrations in small-scale bioreactors. Anal Bioanal Chem 2019; 412:2089-2102. [PMID: 31608427 PMCID: PMC8285309 DOI: 10.1007/s00216-019-02096-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 08/12/2019] [Accepted: 08/27/2019] [Indexed: 12/30/2022]
Abstract
Viable cell concentration (VCC) is one of the most important process attributes during mammalian cell cultivations. Current state-of-the-art measurements of VCC comprise offline methods which do not allow for continuous process data. According to the FDA's process analytical technology initiative, process monitoring and control should be applied to gain process understanding and to ensure high product quality. In this work, the use of an inline capacitance probe to monitor online VCCs of a mammalian CHO cell culture process in small-scale bioreactors (250 mL) was investigated. Capacitance sensors using single frequency are increasingly common for biomass monitoring. However, the single-frequency signal corresponds to the cell polarization that represents the viable cell volume. Therefore single-frequency measurements are dependent on cell diameter changes. Measuring the capacitance across various frequencies (frequency scanning) can provide information about the VCC and cope with changing cell diameter. Applying multivariate data analysis on the frequency scanning data successfully enabled direct online monitoring of VCCs in this study. The multivariate model was trained with data from 5 standard cultivations. The model provided a prediction of VCCs with relative errors from 5.5 to 11%, which is a good agreement with the acceptance criterion based on the offline reference method accuracy (approximately 10% relative error) and strongly improved compared with single-frequency results (16 to 23% relative error). Furthermore, robustness trials were conducted to demonstrate the model's predictive ability under challenging conditions. The process deviations in regard to dilution steps and feed variations were detected immediately in the online prediction of the VCC with relative errors between 6.7 and 13.2%. Thus in summary, the presented method on capacitance frequency scanning demonstrates its suitability for process monitoring and control that can save batches, time, and cost. Graphical abstract.
Collapse
Affiliation(s)
- Sabrina Metze
- Sartorius Stedim Biotech GmbH, August-Spindler-Str. 11, 37079, Göttingen, Germany.,Leibniz University of Hannover, Welfengarten 1, 30161, Hannover, Germany
| | - Stefanie Blioch
- Sartorius Stedim Biotech GmbH, August-Spindler-Str. 11, 37079, Göttingen, Germany
| | - Jens Matuszczyk
- Sartorius Stedim Biotech GmbH, August-Spindler-Str. 11, 37079, Göttingen, Germany
| | - Gerhard Greller
- Sartorius Stedim Biotech GmbH, August-Spindler-Str. 11, 37079, Göttingen, Germany
| | - Christian Grimm
- Sartorius Stedim Biotech GmbH, August-Spindler-Str. 11, 37079, Göttingen, Germany
| | - Jochen Scholz
- Sartorius Stedim Biotech GmbH, August-Spindler-Str. 11, 37079, Göttingen, Germany
| | - Marek Hoehse
- Sartorius Stedim Biotech GmbH, August-Spindler-Str. 11, 37079, Göttingen, Germany.
| |
Collapse
|
7
|
Monitoring online biomass with a capacitance sensor during scale-up of industrially relevant CHO cell culture fed-batch processes in single-use bioreactors. Bioprocess Biosyst Eng 2019; 43:193-205. [PMID: 31549309 PMCID: PMC6960217 DOI: 10.1007/s00449-019-02216-4] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 08/16/2019] [Accepted: 09/10/2019] [Indexed: 12/29/2022]
Abstract
In 2004, the FDA published a guideline to implement process analytical technologies (PAT) in biopharmaceutical processes for process monitoring to gain process understanding and for the control of important process parameters. Viable cell concentration (VCC) is one of the most important key performance indicator (KPI) during mammalian cell cultivation processes. Commonly, this is measured offline. In this work, we demonstrated the comparability and scalability of linear regression models derived from online capacitance measurements. The linear regressions were used to predict the VCC and other familiar offline biomass indicators, like the viable cell volume (VCV) and the wet cell weight (WCW), in two different industrially relevant CHO cell culture processes (Process A and Process B). Therefore, different single-use bioreactor scales (50–2000 L) were used to prove feasibility and scalability of the in-line sensor integration. Coefficient of determinations of 0.79 for Process A and 0.99 for Process B for the WCW were achieved. The VCV was described with high coefficients of determination of 0.96 (Process A) and 0.98 (Process B), respectively. In agreement with other work from the literature, the VCC was only described within the exponential growth phase, but resulting in excellent coefficients of determination of 0.99 (Process A) and 0.96 (Process B), respectively. Monitoring these KPIs online using linear regression models appeared to be scale-independent, enabled deeper process understanding (e.g. here demonstrated in monitoring, the feeding profile) and showed the potential of this method for process control.
Collapse
|
8
|
Ma F, Zhang A, Chang D, Velev OD, Wiltberger K, Kshirsagar R. Real-time monitoring and control of CHO cell apoptosis by in situ multifrequency scanning dielectric spectroscopy. Process Biochem 2019. [DOI: 10.1016/j.procbio.2019.02.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
9
|
Moore B, Sanford R, Zhang A. Case study: The characterization and implementation of dielectric spectroscopy (biocapacitance) for process control in a commercial GMP CHO manufacturing process. Biotechnol Prog 2019; 35:e2782. [DOI: 10.1002/btpr.2782] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Revised: 12/20/2018] [Accepted: 01/28/2019] [Indexed: 01/22/2023]
Affiliation(s)
- Brandon Moore
- Cell Culture Development; Biogen, Research Triangle Park; North Carolina
| | - Ryan Sanford
- Cell Culture Development; Biogen, Research Triangle Park; North Carolina
| | - An Zhang
- Cell Culture Development; Biogen, Research Triangle Park; North Carolina
| |
Collapse
|
10
|
Dielectric Spectroscopy and Optical Density Measurement for the Online Monitoring and Control of Recombinant Protein Production in Stably Transformed Drosophila melanogaster S2 Cells. SENSORS 2018; 18:s18030900. [PMID: 29562633 PMCID: PMC5876727 DOI: 10.3390/s18030900] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 03/14/2018] [Accepted: 03/15/2018] [Indexed: 01/30/2023]
Abstract
The production of recombinant proteins in bioreactors requires real-time process monitoring and control to increase process efficiency and to meet the requirements for a comprehensive audit trail. The combination of optical near-infrared turbidity sensors and dielectric spectroscopy provides diverse system information because different measurement principles are exploited. We used this combination of techniques to monitor and control the growth and protein production of stably transformed Drosophila melanogaster S2 cells expressing antimicrobial proteins. The in situ monitoring system was suitable in batch, fed-batch and perfusion modes, and was particularly useful for the online determination of cell concentration, specific growth rate (µ) and cell viability. These data were used to pinpoint the optimal timing of the key transitional events (induction and harvest) during batch and fed-batch cultivation, achieving a total protein yield of ~25 mg at the 1-L scale. During cultivation in perfusion mode, the OD880 signal was used to control the bleed line in order to maintain a constant cell concentration of 5 × 107 cells/mL, thus establishing a turbidostat/permittistat culture. With this setup, a five-fold increase in productivity was achieved and 130 mg of protein was recovered after 2 days of induced perfusion. Our results demonstrate that both sensors are suitable for advanced monitoring and integration into online control strategies.
Collapse
|
11
|
Sokolov M, Morbidelli M, Butté A, Souquet J, Broly H. Sequential Multivariate Cell Culture Modeling at Multiple Scales Supports Systematic Shaping of a Monoclonal Antibody Toward a Quality Target. Biotechnol J 2018; 13:e1700461. [DOI: 10.1002/biot.201700461] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 11/29/2017] [Indexed: 01/27/2023]
Affiliation(s)
- Michael Sokolov
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences; ETH Zürich Vladimir-Prelog-Weg 1 8093 Zurich Switzerland
| | - Massimo Morbidelli
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences; ETH Zürich Vladimir-Prelog-Weg 1 8093 Zurich Switzerland
| | - Alessandro Butté
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences; ETH Zürich Vladimir-Prelog-Weg 1 8093 Zurich Switzerland
- DataHow AG Vladimir-Prelog-Weg 1; 8093 Zurich Switzerland
| | - Jonathan Souquet
- Merck Serono SA, Biotech Process Sciences Route de Fenil 25; 1804 Corsier-sur-Vevey Switzerland
| | - Hervé Broly
- Merck Serono SA, Biotech Process Sciences Route de Fenil 25; 1804 Corsier-sur-Vevey Switzerland
| |
Collapse
|
12
|
Petiot E, Ansorge S, Rosa-Calatrava M, Kamen A. Critical phases of viral production processes monitored by capacitance. J Biotechnol 2016; 242:19-29. [PMID: 27867077 DOI: 10.1016/j.jbiotec.2016.11.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 11/07/2016] [Accepted: 11/10/2016] [Indexed: 11/28/2022]
Abstract
Over the last decade industrial manufacturing of viral vaccines and viral vectors for prophylactic and therapeutic applications is experiencing a remarkable growth. Currently, the quality attributes of viral derived products are assessed only at the end-point of the production process, essentially because in-process monitoring tools are not available or not implemented at industrial scale. However, to demonstrate process reproducibility and robustness, manufacturers are strongly advised by regulatory agencies to adopt more on-line process monitoring and control. Dielectric spectroscopy has been successfully used as an excellent indicator of the cell culture state in mammalian and yeast cell systems. We previously reported the use of this technique for monitoring influenza and lentiviral productions in HEK293 cell cultures. For both viruses, multi-frequency capacitance measurements allowed not only the on-line monitoring of the production kinetics, but also the identification of the viral release time from the cells. The present study demonstrates that the same approach can be successfully exploited for the on-line monitoring of different enveloped and non-enveloped virus production kinetics in cell culture processes. The on-line monitoring multi-frequency capacitance method was assessed in human HEK293 and Sf9 insect cells expression systems, with viral productions initiated by either infection or transfection. The comparative analyses of all the data acquired indicate that the characteristic capacitance signals were highly correlated with the occurrence of viral replication phases. Furthermore the evolution of the cell dielectric properties (intracellular conductivity and membrane capacitance) were indicative of each main replication steps. In conclusion, multi-frequency capacitance has a great potential for on-line monitoring, supervision and control of viral vector production in cell culture processes.
Collapse
Affiliation(s)
- Emma Petiot
- NRC, Human Health Therapeutics Portfolio, 6100 Royalmount Ave, Montréal, QC, H4P 2R2, Canada; Virologie et Pathologie Humaine - VirPath Team, International Center for Infectious diseases Research, Inserm U1111, CNRS UMR5308, ENS Lyon, Université Claude Bernard Lyon 1, Faculté de Médecine RTH Laennec, Lyon, France.
| | - Sven Ansorge
- NRC, Human Health Therapeutics Portfolio, 6100 Royalmount Ave, Montréal, QC, H4P 2R2, Canada.
| | - Manuel Rosa-Calatrava
- Virologie et Pathologie Humaine - VirPath Team, International Center for Infectious diseases Research, Inserm U1111, CNRS UMR5308, ENS Lyon, Université Claude Bernard Lyon 1, Faculté de Médecine RTH Laennec, Lyon, France.
| | - Amine Kamen
- NRC, Human Health Therapeutics Portfolio, 6100 Royalmount Ave, Montréal, QC, H4P 2R2, Canada; McGill University, Bioengineering Dpt. 817, Sherbrooke St. W., Montreal, QC, H2 B 2C6, Canada.
| |
Collapse
|
13
|
Meitz A, Sagmeister P, Lubitz W, Herwig C, Langemann T. Fed-Batch Production of Bacterial Ghosts Using Dielectric Spectroscopy for Dynamic Process Control. Microorganisms 2016; 4:microorganisms4020018. [PMID: 27681912 PMCID: PMC5029484 DOI: 10.3390/microorganisms4020018] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Revised: 03/11/2016] [Accepted: 03/18/2016] [Indexed: 11/17/2022] Open
Abstract
The Bacterial Ghost (BG) platform technology evolved from a microbiological expression system incorporating the ϕX174 lysis gene E. E-lysis generates empty but structurally intact cell envelopes (BGs) from Gram-negative bacteria which have been suggested as candidate vaccines, immunotherapeutic agents or drug delivery vehicles. E-lysis is a highly dynamic and complex biological process that puts exceptional demands towards process understanding and control. The development of a both economic and robust fed-batch production process for BGs required a toolset capable of dealing with rapidly changing concentrations of viable biomass during the E-lysis phase. This challenge was addressed using a transfer function combining dielectric spectroscopy and soft-sensor based biomass estimation for monitoring the rapid decline of viable biomass during the E-lysis phase. The transfer function was implemented to a feed-controller, which followed the permittivity signal closely and was capable of maintaining a constant specific substrate uptake rate during lysis phase. With the described toolset, we were able to increase the yield of BG production processes by a factor of 8–10 when compared to currently used batch procedures reaching lysis efficiencies >98%. This provides elevated potentials for commercial application of the Bacterial Ghost platform technology.
Collapse
Affiliation(s)
- Andrea Meitz
- Research Center Pharmaceutical Engineering (RCPE) GmbH, Inffeldgasse 13, Graz A-8010, Austria.
| | - Patrick Sagmeister
- Research Division Biochemical Engineering, Institute of Chemical Engineering, Vienna University of Technology, Gumpendorfer Strasse 1A 166/4, Vienna A-1060, Austria.
| | - Werner Lubitz
- Biotech Innovation Research Development and Consulting (BIRD-C) GmbH & Co KG, Dr.-Bohr-Gasse 2-8, Vienna A-1030, Austria.
- Center of Molecular Biology, University of Vienna, Dr.-Bohr-Gasse 9, Vienna A-1030, Austria.
| | - Christoph Herwig
- Research Division Biochemical Engineering, Institute of Chemical Engineering, Vienna University of Technology, Gumpendorfer Strasse 1A 166/4, Vienna A-1060, Austria.
| | - Timo Langemann
- Research Center Pharmaceutical Engineering (RCPE) GmbH, Inffeldgasse 13, Graz A-8010, Austria.
- Biotech Innovation Research Development and Consulting (BIRD-C) GmbH & Co KG, Dr.-Bohr-Gasse 2-8, Vienna A-1030, Austria.
| |
Collapse
|
14
|
Konakovsky V, Yagtu AC, Clemens C, Müller MM, Berger M, Schlatter S, Herwig C. Universal Capacitance Model for Real-Time Biomass in Cell Culture. SENSORS (BASEL, SWITZERLAND) 2015; 15:22128-50. [PMID: 26364635 PMCID: PMC4610510 DOI: 10.3390/s150922128] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Revised: 07/18/2015] [Accepted: 08/25/2015] [Indexed: 11/17/2022]
Abstract
: Capacitance probes have the potential to revolutionize bioprocess control due to their safe and robust use and ability to detect even the smallest capacitors in the form of biological cells. Several techniques have evolved to model biomass statistically, however, there are problems with model transfer between cell lines and process conditions. Errors of transferred models in the declining phase of the culture range for linear models around +100% or worse, causing unnecessary delays with test runs during bioprocess development. The goal of this work was to develop one single universal model which can be adapted by considering a potentially mechanistic factor to estimate biomass in yet untested clones and scales. The novelty of this work is a methodology to select sensitive frequencies to build a statistical model which can be shared among fermentations with an error between 9% and 38% (mean error around 20%) for the whole process, including the declining phase. A simple linear factor was found to be responsible for the transferability of biomass models between cell lines, indicating a link to their phenotype or physiology.
Collapse
Affiliation(s)
- Viktor Konakovsky
- Institute of Chemical Engineering, Division of Biochemical Engineering, Vienna University of Technology, Gumpendorfer Strasse 1A 166-4, 1060 Vienna, Austria.
| | - Ali Civan Yagtu
- Institute of Chemical Engineering, Division of Biochemical Engineering, Vienna University of Technology, Gumpendorfer Strasse 1A 166-4, 1060 Vienna, Austria.
| | - Christoph Clemens
- Boehringer Ingelheim Pharma GmbH & Co. KG Department Bioprocess Development, 88400 Biberach, Germany.
| | - Markus Michael Müller
- Boehringer Ingelheim Pharma GmbH & Co. KG Department Bioprocess Development, 88400 Biberach, Germany.
| | - Martina Berger
- Boehringer Ingelheim Pharma GmbH & Co. KG Department Bioprocess Development, 88400 Biberach, Germany.
| | - Stefan Schlatter
- Boehringer Ingelheim Pharma GmbH & Co. KG Department Bioprocess Development, 88400 Biberach, Germany.
| | - Christoph Herwig
- Institute of Chemical Engineering, Division of Biochemical Engineering, Vienna University of Technology, Gumpendorfer Strasse 1A 166-4, 1060 Vienna, Austria.
| |
Collapse
|
15
|
The Application of Dielectric Spectroscopy and Biocalorimetry for the Monitoring of Biomass in Immobilized Mammalian Cell Cultures. Processes (Basel) 2015. [DOI: 10.3390/pr3020384] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|