1
|
Brucchi F, Limongi C, Masci E, De Stefano F, Pelfini E, Cassini D, Clarizia G, Franzini M, Faillace G. Case Report: Combined Laparoscopic Perineal Hernia and Abdominal Parastomal Hernia Repair With a Mesh After Abdominoperineal Resection: A Video Vignette and Review of the Literature. JOURNAL OF ABDOMINAL WALL SURGERY : JAWS 2024; 3:13261. [PMID: 39651457 PMCID: PMC11620875 DOI: 10.3389/jaws.2024.13261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 10/30/2024] [Indexed: 12/11/2024]
Abstract
Background Postoperative perineal hernia (PH) is an uncommon complication after abdominoperineal resection (APR). Different techniques have been described in literature and there is no consensus regarding the optimal repair approach. In the present study, we reported a case of a laparoscopic combined repair of a perineal hernia and abdominal parastomal hernia (PSH) with mesh. Studies have shown that the prosthetic PSH and PH repair can be performed at the same time by laparoscopy with the same trocars positioning, adding the advantages of minimally invasive surgery and avoiding large laparotomy. Methods A literature search in Pubmed was performed. All articles in English describe laparoscopic repair of combined perineal and parastomal hernias. A case presentation of an 83-year-old woman with combined parastomal and perineal hernias after abdominoperineal resection (APR) shown in a video vignette is provided. Results Three single patient case reports published between 2016 and 2023 were found in literature. Two patients with rectal cancer underwent APR procedure, while the third patient underwent an anterior pelvic exenteration (APE) for carcinoma of the urinary bladder (CUB). The laparoscopic procedures did not require conversion and all procedures successfully closed the defect using a mesh. In our case, the operative time was 3 h with the major time spent for PH repair. The intraoperative blood loss was non-significant and the postoperative course was regular. The patient has been discharged on the fourth postoperative day. At 1 year follow-up, the patient noticed a great improvement in her daily-life due to the absence of the previous discomforts and there was no evidence of early recurrence or other postoperative complications. Conclusion Combined laparoscopic transabdominal PH and PSH repair with the use of synthetic mesh was shown to be a safe and effective repair for this rare disorder. To accurately compare techniques, we require prospective studies with longer follow up durations.
Collapse
Affiliation(s)
- F. Brucchi
- General Surgery Grad School, University of Milano Statale, Milan, Italy
| | - C. Limongi
- General Surgery Grad School, University of Milano Statale, Milan, Italy
- Department of General Surgery, ASST Nord Milano, Milano, Italy
| | - E. Masci
- Department of General Surgery, ASST Nord Milano, Milano, Italy
| | - F. De Stefano
- Department of General Surgery, ASST Nord Milano, Milano, Italy
| | - E. Pelfini
- General Surgery Grad School, University of Milano Statale, Milan, Italy
- Department of General Surgery, ASST Nord Milano, Milano, Italy
| | - D. Cassini
- Department of General Surgery, ASST Nord Milano, Milano, Italy
| | - G. Clarizia
- Department of General Surgery, ASST Valtellina e Alto Lario, Sondrio, Italy
| | - M. Franzini
- Department of General Surgery, ASST Valtellina e Alto Lario, Sondrio, Italy
| | - G. Faillace
- Department of General Surgery, ASST Nord Milano, Milano, Italy
| |
Collapse
|
2
|
Priego P, Juez LD, Cuadrado M, García Pérez JC, Sánchez-Picot S, Blázquez LA, Gil P, Galindo J, Fernández-Cebrián JM. Risk factors associated with radiological and clinical recurrences after laparoscopic repair of large hiatal hernia with TiO 2Mesh™ reinforcement. Hernia 2024; 28:1871-1877. [PMID: 39001940 DOI: 10.1007/s10029-024-03107-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 07/01/2024] [Indexed: 07/15/2024]
Abstract
INTRODUCTION Laparoscopic repair of large para-esophageal hiatal hernias (LPHH) remains controversial. Several meta-analyses suggest hiatus reinforcement with mesh has better outcomes over cruroplasty in terms of less recurrence. The aim of this study was to evaluate the medium-term results of treating LPHH with a biosynthetic monofilament polypropylene mesh coated with titanium dioxide to enhance biocompatibility (TiO2Mesh™). METHODS A retrospective observational study, using data extracted from a prospectively collected database was performed at XXX from December 2014 to June 2023. Included participants were all patients who underwent laparoscopic repair of large (> 5 cm) type III hiatal hernia in which a TiO2Mesh™ was used. The results of the study, including clinical and radiological recurrences as well as mesh-related morbidity, were analyzed. RESULTS Sixty-seven patients were finally analyzed. Laparoscopic approach was attempted in all but conversion was needed in one patient because of bleeding in the lesser curvature. With a median follow-up of 41 months (and 10 losses to follow-up), 22% of radiological recurrences and 19.3% of clinical recurrences were described. Regarding complications, one patient presented morbidity associated with the mesh (mesh erosion requiring endoscopic extraction). Recurrent hernia repair was an independent factor of clinical recurrence (OR 4.57 95% CI (1.28-16.31)). CONCLUSION LPHH with TiO2Mesh™ is safe and feasible with a satisfactory medium-term recurrence and a low complication rate. Prospective randomized studies are needed to establish the standard repair of LPHH.
Collapse
Affiliation(s)
- Pablo Priego
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario La Paz, Universidad Autónoma de Madrid, Madrid, Spain
| | - Luz Divina Juez
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain.
| | - Marta Cuadrado
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain
| | - Juan Carlos García Pérez
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain
- Department of Surgery, Universidad de Alcalá, Madrid, Spain
| | - Silvia Sánchez-Picot
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain
| | - Luis Alberto Blázquez
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain
- Department of Surgery, Universidad de Alcalá, Madrid, Spain
| | - Pablo Gil
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain
- Department of Surgery, Universidad de Alcalá, Madrid, Spain
| | - Julio Galindo
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain
- Department of Surgery, Universidad de Alcalá, Madrid, Spain
| | - José María Fernández-Cebrián
- Division of Esophagogastric and Bariatric Surgery, Department of General and Digestive Surgery, Facultad de Medicina, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain
- Department of Surgery, Universidad de Alcalá, Madrid, Spain
| |
Collapse
|
3
|
Latorre-Rodríguez AR, Rajan A, Mittal SK. Cruroplasty with or without mesh? A systematic literature review with a novel time-organized proportion meta-analysis. Surg Endosc 2024; 38:1685-1708. [PMID: 38351425 DOI: 10.1007/s00464-024-10683-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 12/30/2023] [Indexed: 04/02/2024]
Abstract
BACKGROUND Improved outcomes with the use of non-absorbable mesh (NAM) for inguinal hernia repairs led to its rapid adoption for hiatal hernia (HH) repairs; however, feared complications occurred, and the trend shifted toward using absorbable mesh (AM). We aimed to analyze the literature assessing objective HH recurrence rates after primary laparoscopic cruroplasty with or without the use of different mesh types. METHODS A systematic literature review with both pairwise and time-organized proportion meta-analyses of articles published between January 1993 and September 2022 was performed using the MEDLINE, EMBASE, and Taylor & Francis databases to identify relevant studies comparing groups undergoing cruroplasty with suture repair (SR) alone, AM, NAM, or partially absorbable mesh (PAM). Studies documenting an objective follow-up ≥ 6 months were included. The primary outcome was the HH recurrence rate confirmed by barium esophagram or upper GI endoscopy. RESULTS A total of 34 studies met the inclusion criteria, including 6 randomized clinical trials, 25 retrospectives studies, and 3 prospective cohort studies. A total of 2170 subjects underwent laparoscopic HH repair and completed an objective follow-up ≥ 6 months after surgery; the objective recurrence rate was 20.8% (99/477) at a mean follow-up of 25.8 ± 16.4 months for the SR group, 20.6% (244/1187) at 28.1 ± 13.8 months for the AM group, 13.7% (65/475) at 30.8 ± 15.3 months for the NAM group, and 0% (0/31) at 32.5 ± 13.5 months for the PAM group. However, the pairwise meta-analysis revealed that overall mesh use was not superior to SR in preventing long-term HH recurrence. CONCLUSION The use of AM does not appear to reduce HH recurrence compared to SR alone. Although the data favors NAM to decrease objective HH recurrence in the mid-term, the long-term (≥ 48 months) recurrence rate was similar with or without any type of mesh.
Collapse
Affiliation(s)
- Andrés R Latorre-Rodríguez
- Norton Thoracic Institute, St. Joseph's Hospital and Medical Center, 500 W Thomas Road, Suite 500, Phoenix, AZ, 85013, USA
- Universidad del Rosario. Escuela de Medicina y Ciencias de la Salud, Grupo de Investigación Clínica, Bogotá D.C., Colombia
| | - Ajay Rajan
- School of Medicine School, Creighton University, Phoenix, AZ, USA
| | - Sumeet K Mittal
- Norton Thoracic Institute, St. Joseph's Hospital and Medical Center, 500 W Thomas Road, Suite 500, Phoenix, AZ, 85013, USA.
- School of Medicine School, Creighton University, Phoenix, AZ, USA.
| |
Collapse
|
4
|
Elniel M, Chaudhury M, Desai N, Lo C, Daté RS. Could "Low Quality of Life" Rather Than "Significant Symptoms" Be Better Criteria for the Selection of Patients for the Repair of a Giant Hiatus Hernia? Cureus 2024; 16:e55740. [PMID: 38586797 PMCID: PMC10998715 DOI: 10.7759/cureus.55740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2024] [Indexed: 04/09/2024] Open
Abstract
Purpose Giant hiatus hernia (GHH) repair is undertaken electively in symptomatic patients, to prevent complications such as gastric volvulus and subsequent mortality. Advances in laparoscopy and perioperative care have reduced the risk of GHH repair, and improvement in quality of life (QoL) has become an important outcome measure. In our unit, we have been assessing QoL in all the operated as well as non-operated patients with GHH, using the "Quality of Life in Reflux and Dyspepsia" (QOLRAD) questionnaire. We sought to evaluate differences in QoL between patients who were managed conservatively for GHH and those who underwent GHH repair over a two-year period. Methods All patients seen in the Upper Gastrointestinal Tertiary Unit in Lancashire Teaching Hospitals NHS Trust with GHH between January 2015 and December 2022 were identified from a prospectively kept database. QOLRAD scores were analyzed and compared between conservatively and operatively managed patients using the Mann-Whitney U test. Demographic and operative outcome data were also collected. Results Eighty-seven patients with GHH were included. QoL of 51 patients improved significantly after elective surgery. Five out of 36 patients, who were initially treated conservatively, elected to have repair during their follow-up period. These 5 Patients had a lower initial QOLRAD score in comparison to those whose management remained conservative (2.72 vs 5.05, Mann Whitney U test p=0.034), and their QOLRAD scores also improved significantly after the operation. QOLRAD scores in conservatively managed patients remained stable over a two-year follow-up period. Conclusion Objectively calculated low QoL may be a more useful tool than subjective symptoms in selecting patients for elective repair of GHH.
Collapse
Affiliation(s)
- Mohammed Elniel
- General Surgery, Lancashire Teaching Hospitals, Preston, GBR
| | - Madhu Chaudhury
- General Surgery, Lancashire Teaching Hospitals, Preston, GBR
| | - Nasreen Desai
- General Surgery, Lancashire Teaching Hospitals, Preston, GBR
| | - Christina Lo
- General Surgery, Lancashire Teaching Hospitals, Preston, GBR
| | - Ravindra S Daté
- General Surgery, Lancashire Teaching Hospitals, Preston, GBR
| |
Collapse
|
5
|
Khaled I, Priego P, Faisal M, Cuadrado M, García-Moreno F, Ballestero A, Galindo J, Lobo E. Assessment of short-term outcome with TiO 2 mesh in laparoscopic repair of large paraesophageal hiatal hernias. BMC Surg 2019; 19:156. [PMID: 31660930 PMCID: PMC6816156 DOI: 10.1186/s12893-019-0607-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Accepted: 09/13/2019] [Indexed: 02/07/2023] Open
Abstract
Background Laparoscopic large para-oesophageal hiatal hernia (LPHH) repair using mesh reinforcement significantly reduces postoperative recurrence rates compared to conventional suture repair, especially within short follow-up times. However, the ideal strategy for repairing LPHH remains disputable because no clear guidelines are given regarding indications, mesh type, shape or position. The aim of this study was to survey our short-term results of LPHH management with a biosynthetic monofilament polypropylene mesh coated with titanium dioxide to enhance biocompatibility (TiO2Mesh™). Methods A retrospective study was performed at Ramon y Cajal University Hospital, Spain from December 2014 to October 2018. Data were collected on 27 consecutive patients with extensive hiatal hernia defects greater than 5 cm for which a laparoscopic repair was performed by primary suture and additional reinforcement with a TiO2Mesh™. Study outcomes were investigated, including clinical and radiological recurrences, dysphagia and mesh-related drawbacks. Results Twenty-seven patients were included in our analysis; 10 patients were male, and 17 were female. The mean age was 73 years (range, 63–79 years). All operations were performed laparoscopically. The median postoperative hospital stay was 3 days. After a mean follow-up of 18 months (range, 8-29 months), only 3 patients developed clinical recurrence of reflux symptoms (11%), and 2 had radiological recurrences (7%). No mesh-related complications occurred. Conclusions TiO2Mesh™ was found to be safe for laparoscopic repair of LPHH with a fairly low recurrence rate in this short-term study. Long-term studies conducted over a period of years with large sample sizes will be essential for confirming whether this mesh is suitable as a standard method of care with few drawbacks.
Collapse
Affiliation(s)
- Islam Khaled
- Department of Surgery, Suez Canal University Hospitals and Medical School, Ismailia, Egypt
| | - Pablo Priego
- Division of Esophagogastric, Bariatric and Minimally Invasive Surgery, Department of Surgery, Ramon y Cajal University Hospital, Crta. Colmenar Viejo Km 9,100, 28034, Madrid, Spain.
| | - Mohammed Faisal
- Department of Surgery, Suez Canal University Hospitals and Medical School, Ismailia, Egypt
| | - Marta Cuadrado
- Division of Esophagogastric, Bariatric and Minimally Invasive Surgery, Department of Surgery, Ramon y Cajal University Hospital, Crta. Colmenar Viejo Km 9,100, 28034, Madrid, Spain
| | - Francisca García-Moreno
- Division of Esophagogastric, Bariatric and Minimally Invasive Surgery, Department of Surgery, Ramon y Cajal University Hospital, Crta. Colmenar Viejo Km 9,100, 28034, Madrid, Spain
| | - Araceli Ballestero
- Division of Esophagogastric, Bariatric and Minimally Invasive Surgery, Department of Surgery, Ramon y Cajal University Hospital, Crta. Colmenar Viejo Km 9,100, 28034, Madrid, Spain
| | - Julio Galindo
- Division of Esophagogastric, Bariatric and Minimally Invasive Surgery, Department of Surgery, Ramon y Cajal University Hospital, Crta. Colmenar Viejo Km 9,100, 28034, Madrid, Spain
| | - Eduardo Lobo
- Division of Esophagogastric, Bariatric and Minimally Invasive Surgery, Department of Surgery, Ramon y Cajal University Hospital, Crta. Colmenar Viejo Km 9,100, 28034, Madrid, Spain
| |
Collapse
|
6
|
Chitosan Cross-Linked Bio-based Antimicrobial Polypropylene Meshes for Hernia Repair Loaded with Levofloxacin HCl via Cold Oxygen Plasma. COATINGS 2019. [DOI: 10.3390/coatings9030168] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Polypropylene (PP) large pore size nets have been most widely used implants for hernia repair. Nevertheless, the growth of bacteria within PP mesh pores after operation is a major reason of hernia recurrence. Secondly, pre-operative prophylaxis during mesh implantation has failed due to the hydrophobic nature of PP meshes. Herein, chitosan cross-linked and levofloxacin HCl incorporated, antimicrobial PP mesh devices were prepared using citric acid as a bio-based and green cross-linking agent. The inert PP mesh fibers were surface activated using O2 plasma treatment at low pressure. Then, chitosan of different molecular weights (low and medium weight) were cross-linked with O2 plasma activated surfaces using citric acid. Scanning electron microscopy (SEM), energy dispersive X-ray (EDX) spectroscopy, and Fourier transform infrared (FTIR) spectroscopy confirmed that chitosan was cross-linked with O2 plasma-treated PP mesh surfaces and formed a thin layer of chitosan and levofloxacin HCl on the PP mesh surfaces. Moreover, antimicrobial properties of chitosan and levofloxacin HCl-coated PP meshes were investigated using an agar plate release method. The coated PP meshes demonstrated excellent antimicrobial inhibition zone up to 10 mm. Thus, modified PP meshes demonstrated sustained antimicrobial properties for six continuous days against Staphylococcus aureus (SA) and Escherichia coli (EC) bacteria.
Collapse
|
7
|
Polydopamine-Inspired Surface Modification of Polypropylene Hernia Mesh Devices via Cold Oxygen Plasma: Antibacterial and Drug Release Properties. COATINGS 2019. [DOI: 10.3390/coatings9030164] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Mesh infection is a major complication of hernia surgery after polypropylene (PP) mesh implantation. Modifying the PP mesh with antibacterial drugs is an effective way to reduce the chance of infection, but the hydrophobic characteristic of PP fibers has obstructed the drug adhesion. Therefore, to prepare antimicrobial PP mesh with a stable drug coating layer and to slow the drug release property during the hernia repair process has a great practical meaning. In this work, PP meshes were coated by bio-inspired polydopamine (PDA), which can load and release levofloxacin. PP meshes were activated with cold oxygen plasma and then plasma activated PP fibers were coated with PDA. The PDA coated meshes were further soaked in levofloxacin. The levofloxacin loaded PP meshes demonstrate excellent antimicrobial properties for 6 days and the drug release has lasted for at least 24 h. Moreover, a control PP mesh sample without plasma treatment was also prepared, after coating with PDA and loading levofloxacin. The antimicrobial property was sustained only for two days. The maximum inhibition zone of PDA coated meshes with and without plasma treatment was 12.5 and 9 mm, respectively. On all accounts, the modification strategy can facilely lead to long-term property of infection prevention.
Collapse
|
8
|
One-Step Surface Functionalized Hydrophilic Polypropylene Meshes for Hernia Repair Using Bio-Inspired Polydopamine. FIBERS 2019. [DOI: 10.3390/fib7010006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
An ideal hernia mesh is one that absorbs drugs and withstands muscle forces after mesh implantation. Polypropylene (PP) mesh devices have been accepted as a standard material to repair abdominal hernia, but the hydrophobicity of PP fibers makes them unsuitable to carry drugs during the pre-implantation of PP meshes. In this study, for the first time, one-step functionalization of PP mesh surfaces was performed to incorporate bio-inspired polydopamine (PDA) onto PP surfaces. All PP mesh samples were dipped in the same concentration of dopamine solution. The surface functionalization of PP meshes was performed for 24 h at 37 °C and 80 rpm. It was proved by scanning electron microscopic (SEM) images and Fourier Transform Infrared Spectroscopy (FTIR) results that a thin layer of PDA was connected with PP surfaces. Moreover, water contact angle results proved that surface functionalized PP meshes were highly hydrophilic (73.1°) in comparison to untreated PP mesh surfaces (138.5°). Thus, hydrophilic PP meshes with bio-inspired poly-dopamine functionalization could be a good choice for hernia mesh implantation.
Collapse
|
9
|
Sanbhal N, Saitaer X, Li Y, Mao Y, Zou T, Sun G, Wang L. Controlled Levofloxacin Release and Antibacterial Properties of β-Cyclodextrins-Grafted Polypropylene Mesh Devices for Hernia Repair. Polymers (Basel) 2018; 10:E493. [PMID: 30966527 PMCID: PMC6415403 DOI: 10.3390/polym10050493] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2018] [Revised: 04/29/2018] [Accepted: 05/01/2018] [Indexed: 01/08/2023] Open
Abstract
Mesh infection is a major complication of hernia repair. After knitted mesh implantation, bacteria can grow within textile structures causing infection. In this work, polypropylene (PP) mesh devices were two-step grafted with hexamethylene diisocyanate (HDI) and β⁻cyclodexrins (CD) and then loaded with suitable antimicrobial levofloxacin HCL for hernia mesh-infection prevention. First, oxygen plasma was able to create surface roughness, then HDI was successfully grafted onto PP fiber surfaces. Afterwards, CD was covalently grafted onto the HDI treated PP meshes, and levofloxacin HCL (LVFX) was loaded into the CD cavity of the modified meshes. The modified devices were evaluated for sustained antibiotic properties and drug-release profiles in a phosphate buffer, and sustained drug release was observed between interfaces of meshes and aqueous environment. The antibiotic-loaded PP mesh samples demonstrated sustained antibacterial properties for 7 and 10 days, respectively, against both Gram-negative and Gram-positive bacteria. The CD-captured levofloxacin HCL showed burst release after 6 h but later exhibited sustained release for the next 48 h. Among all samples, the modified mesh LVFX-6 was more stable and showed more sustained drug release and could be employed in future clinical applications.
Collapse
Affiliation(s)
- Noor Sanbhal
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
- Department of Textile Engineering, Mehran University of Engineering and Technology Jamshoro, Sindh 76062, Pakistan.
| | - Xiakeer Saitaer
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
- College of Textiles and Fashion, Xingjiang University, 666 Sheng Li Road, Tian Shan, Wulumuqi 830046, China.
| | - Yan Li
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
| | - Ying Mao
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
| | - Ting Zou
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
| | - Gang Sun
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
- Division of Textiles and Clothing, University of California, Davis, CA 95616, USA.
| | - Lu Wang
- Key Laboratory of Textile Science and Technology of Ministry of Education, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
| |
Collapse
|
10
|
Gordon AC, Gillespie C, Son J, Polhill T, Leibman S, Smith GS. Long-term outcomes of laparoscopic large hiatus hernia repair with nonabsorbable mesh. Dis Esophagus 2018; 31:4850447. [PMID: 29444215 DOI: 10.1093/dote/dox156] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Accepted: 12/06/2017] [Indexed: 12/11/2022]
Abstract
The use of mesh to augment suture repair of large hiatus hernias remains controversial. Repair with mesh may help reduce the recurrence rate of primary repair, but concerns about the potential for serious complications, such as mesh erosion or stricturing, continue to limit its use. We aim to evaluate the long-term outcome of primary hiatus hernia repair with lightweight polypropylene mesh (TiMesh) specifically looking at rates of clinical recurrence, dysphagia, and mesh-related complications. From a prospectively maintained database, 50 consecutive patients who underwent elective primary laparoscopic hiatal hernia repair with TiMesh between January 2005 and December 2007 were identified. Case notes and postoperative endoscopy reports were reviewed. Clinical outcomes were evaluated using a structured questionnaire, including a validated dysphagia score. Of the 50 patients identified, 36 (72%) were contactable for follow-up. At a median follow-up of 9 years, the majority of patients (97%) regarded their surgery as successful. Twelve patients (33%) reported a recurrence of their symptoms, but only 4 (11%) reported that their symptoms were as severe as prior to the surgery. There was no significant difference between pre- and postoperative dysphagia scores. Postoperative endoscopy reports were available for 32 patients at a median time point of 4 years postoperatively, none of which revealed any mesh-related complications. One patient had undergone a revision procedure for a recurrent hernia at another institution. In this series, primary repair of large hiatus hernia with nonabsorbable mesh was not associated with any adverse effects over time. Patient satisfaction with symptomatic outcome remained high in the long term.
Collapse
Affiliation(s)
- A C Gordon
- Department of Upper Gastrointestinal Surgery, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - C Gillespie
- Department of Upper Gastrointestinal Surgery, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - J Son
- Department of Upper Gastrointestinal Surgery, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - T Polhill
- Department of Upper Gastrointestinal Surgery, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - S Leibman
- Department of Upper Gastrointestinal Surgery, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - G S Smith
- Department of Upper Gastrointestinal Surgery, Royal North Shore Hospital, Sydney, New South Wales, Australia
| |
Collapse
|
11
|
Sanbhal N, Mao Y, Sun G, Li Y, Peerzada M, Wang L. Preparation and Characterization of Antibacterial Polypropylene Meshes with Covalently Incorporated β-Cyclodextrins and Captured Antimicrobial Agent for Hernia Repair. Polymers (Basel) 2018; 10:E58. [PMID: 30966099 PMCID: PMC6415163 DOI: 10.3390/polym10010058] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 12/20/2017] [Accepted: 01/05/2018] [Indexed: 11/30/2022] Open
Abstract
Polypropylene (PP) light weight meshes are commonly used as hernioplasty implants. Nevertheless, the growth of bacteria within textile knitted mesh intersections can occur after surgical mesh implantation, causing infections. Thus, bacterial reproduction has to be stopped in the very early stage of mesh implantation. Herein, novel antimicrobial PP meshes grafted with β-CD and complexes with triclosan were prepared for mesh infection prevention. Initially, PP mesh surfaces were functionalized with suitable cold oxygen plasma. Then, hexamethylene diisocyanate (HDI) was successfully grafted on the plasma-activated PP surfaces. Afterwards, β-CD was connected with the already HDI reacted PP meshes and triclosan, serving as a model antimicrobial agent, was loaded into the cyclodextrin (CD) cavity for desired antibacterial functions. The hydrophobic interior and hydrophilic exterior of β-CD are well suited to form complexes with hydrophobic host guest molecules. Thus, the prepared PP mesh samples, CD-TCL-2 and CD-TCL-6 demonstrated excellent antibacterial properties against Staphylococcus aureus and Escherichia coli that were sustained up to 11 and 13 days, respectively. The surfaces of chemically modified PP meshes showed dramatically reduced water contact angles. Moreover, X-ray diffractometer (XRD), differential scanning calorimeter (DSC), and Thermogravimetric (TGA) evidenced that there was no significant effect of grafted hexamethylene diisocyanate (HDI) and CD on the structural and thermal properties of the PP meshes.
Collapse
Affiliation(s)
- Noor Sanbhal
- Key Laboratory of Textile Science and Technology of Ministry of Education, Room 4023, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
- Department of Textile Engineering, Mehran University of Engineering and Technology, Jamshoro 76062, Sindh, Pakistan.
| | - Ying Mao
- Key Laboratory of Textile Science and Technology of Ministry of Education, Room 4023, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
| | - Gang Sun
- Key Laboratory of Textile Science and Technology of Ministry of Education, Room 4023, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
- Division of Textiles and Clothing, University of California, Davis, CA 95616, USA.
| | - Yan Li
- Key Laboratory of Textile Science and Technology of Ministry of Education, Room 4023, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
| | - Mazhar Peerzada
- Department of Textile Engineering, Mehran University of Engineering and Technology, Jamshoro 76062, Sindh, Pakistan.
| | - Lu Wang
- Key Laboratory of Textile Science and Technology of Ministry of Education, Room 4023, College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang, Shanghai 201620, China.
| |
Collapse
|
12
|
Dubuisson JB, Veit-Rubin N, Wenger JM, Dubuisson J. [Laparoscopic lateral suspension, another way to treat genital prolapse]. ACTA ACUST UNITED AC 2017; 45:32-36. [PMID: 28238313 DOI: 10.1016/j.gofs.2016.12.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Accepted: 10/21/2016] [Indexed: 11/29/2022]
Abstract
The laparoscopic sacrocolpopexy is the treatment of choice of pelvic organ prolapses since more than twenty years. The laparoscopic lateral suspension with mesh is an alternative technique. Its originality is the subperitoneal passing of the lateral arm of the mesh in the lateral abdominal wall, leaving the skin above the iliac crest, in a place without risks of vascular, nerve, bowel injuries. We report in this article the results of the three main publications on the subject. The indications are cystocele and apical descent. It can be envisaged when the access of the promontory is difficult; for instance in the presence of obesity, adhesions, sigmoid megacolon, or low position of the left common iliac vein, partially covering the promontory. It is also a practical technique for surgeons having a moderate experience of the promontory access.
Collapse
Affiliation(s)
- J B Dubuisson
- Clinique La Colline, université de Genève, 1206 Genève, Suisse.
| | - N Veit-Rubin
- Service de gynécologie-obstétrique, centre hospitalo-universitaire vaudois, 46, rue de Bugnon, 1011 Lausanne, Suisse
| | - J M Wenger
- Service de gynécologie-obstétrique, hôpitaux universitaires de Genève, 30, boulevard de la Cluse, 1205 Genève, Suisse
| | - J Dubuisson
- Service de gynécologie-obstétrique, hôpitaux universitaires de Genève, 30, boulevard de la Cluse, 1205 Genève, Suisse
| |
Collapse
|
13
|
Wang WP, Ni PZ, Chen LQ. Laparoscopic surgical treatment of esophageal hiatal hernia. Shijie Huaren Xiaohua Zazhi 2016; 24:3087-3097. [DOI: 10.11569/wcjd.v24.i20.3087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Types II, III and IV esophageal hiatal hernia (EHH) which presents obvious symptoms or leads to potentially fatal complications requires surgical treatment. Laparoscopy has been used to repair EHH in the last two decades globally and proved to be minimally invasive compared to conventional open surgery. This review summarizes current status and prospectives of laparoscopic application in EHH treatment. The published articles on minimally invasive laparoscopic surgical treatment of EHH in PubMed, Cochrane Library and EMBASE databases were retrieved and analyzed. From 1992 to 2015, 86 English articles involving a total of 4771 patients receiving laparoscopic treatment for EHH were retrieved. Perioperative information including safety and feasibility of procedure, postoperative complications, and short/long-term outcome after laparoscopic repair was retrospectively analyzed. Laparoscopic surgical treatment of EHH is a safe, feasible and minimally invasive procedure with fast recovery after repair, low postoperative morbidity and recurrence.
Collapse
|
14
|
Affiliation(s)
- A Duranceau
- Department of Surgery, Division of Thoracic Surgery, Université de Montréal, Montreal, Quebec, Canada
| |
Collapse
|
15
|
Antonakis F, Köckerling F, Kallinowski F. Functional Results after Repair of Large Hiatal Hernia by Use of a Biologic Mesh. Front Surg 2016; 3:16. [PMID: 27014698 PMCID: PMC4783575 DOI: 10.3389/fsurg.2016.00016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Accepted: 02/25/2016] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The aim of this observational study is to analyze the results of patients with large hiatal hernia and upside-down stomach after surgical closure with a biological mesh (Permacol(®), Covidien, Neustadt an der Donau, Germany). Biological mesh is used to prevent long-term detrimental effects of artificial meshes and to reduce recurrence rates. METHODS A total of 13 patients with a large hiatal hernia and endothoracic stomach, who underwent surgery between 2010 and 2014, were included. Interviews and upper endoscopy were conducted to determine recurrences, lifestyle restrictions, and current complaints. RESULTS After a mean follow-up of 26 ± 18 months (range: 3-58 months), 10 patients (3 men, mean age 73 ± 13, range: 26-81 years) were evaluated. A small recurrent axial hernia was found in one patient postoperatively. Dysphagia was the most common complaint (four cases); while in one case, the problem was solved after endoscopic dilatation. In three cases, bloat and postprandial pain were documented. In one case, an explantation of the mesh was necessary due to mesh migration and painful adhesions. In one further case with gastroparesis, pyloroplasty was performed without success. The data are compared to the available literature. It was found that dysphagia and recurrence rates are unrelated both in biological and in synthetic meshes if the esophagus is encircled. In series preserving the esophagus at least partially uncoated, recurrences after the use of biological meshes relieve dysphagia. After the application of synthetic meshes, dysphagia is aggravated by recurrences. CONCLUSION Recurrence is rare after encircling hiatal hernia repair with the biological mesh Permacol(®). Dysphagia, gas bloat, and intra-abdominal pain are frequent complaints. Despite the small number of patients, it can be concluded that a biological mesh may be an alternative to synthetic meshes to reduce recurrences at least for up to 2 years. Our study demonstrates that local fibrosis and thickening of the mesh can affect the outcome being associated with abdominal discomfort despite a successful repair. The review of the literature indicates comparable results after 2 years with both biologic and synthetic meshes embracing the esophagus. At the same point in time, reconstruction with synthetic and biologic materials differs when the esophagus is not or only partially encircled in the repair. This is important since encircling artificial meshes can erode the esophagus after 5-10 years.
Collapse
Affiliation(s)
- Filimon Antonakis
- Department of General and Visceral Surgery, Asklepios Klinikum Harburg , Hamburg , Germany
| | - Ferdinand Köckerling
- Department of General, Visceral and Vascular Surgery, Vivantes Klinikum Spandau , Berlin , Germany
| | - Friedrich Kallinowski
- Department of General and Visceral Surgery, Asklepios Klinikum Harburg , Hamburg , Germany
| |
Collapse
|
16
|
Kazantsev AA, Parshikov VV, Shemyatovsky KA, Alekhin AI, Titarov DL, Kolpakov AA, Osadchenko SV. [The titanium-containing mesh as a perspective group of implants for abdominal wall repair]. Khirurgiia (Mosk) 2016. [PMID: 28635687 DOI: 10.17116/hirurgia2016486-95] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- A A Kazantsev
- Central Clinical Hospital of the Russian Academy of Sciences, Moscow
| | - V V Parshikov
- Chair of Hospital Surgery of Nizhny Novgorod State Medical Academy, Nizhny Novgorod
| | - K A Shemyatovsky
- Chair of Operative Surgery of Nizhny Novgorod State Medical Academy, Nizhny Novgorod
| | - A I Alekhin
- Central Clinical Hospital of the Russian Academy of Sciences, Moscow
| | - D L Titarov
- Chair of Operative Surgery of Nizhny Novgorod State Medical Academy, Nizhny Novgorod
| | | | - S V Osadchenko
- D.I. Mendeleev Russian Chemical-Technological University, Moscow
| |
Collapse
|
17
|
Physical Characteristics of Medical Textile Prostheses Designed for Hernia Repair: A Comprehensive Analysis of Select Commercial Devices. MATERIALS 2015; 8:8148-8168. [PMID: 28793704 PMCID: PMC5458830 DOI: 10.3390/ma8125453] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2015] [Revised: 11/17/2015] [Accepted: 11/25/2015] [Indexed: 01/25/2023]
Abstract
Inguinal hernia repairs are among the most frequent operations performed worldwide. This study aims to provide further understanding of structural characteristics of hernia prostheses, and better comprehensive evaluation. Weight, porosity, pore size and other physical characteristics were evaluated; warp knitting structures were thoroughly discussed. Two methods referring to ISO 7198:1998, i.e., weight method and area method, were employed to calculate porosity. Porosity ranged from 37.3% to 69.7% measured by the area method, and 81.1% to 89.6% by the weight method. Devices with two-guide bar structures displayed both higher porosity (57.7%–69.7%) and effective porosity (30.8%–60.1%) than single-guide bar structure (37.3%–62.4% and 0%–5.9%, respectively). Filament diameter, stitch density and loop structure combined determined the thickness, weight and characteristics of pores. They must be well designed to avoid zero effective porosity regarding a single-bar structure. The area method was more effective in characterizing flat sheet meshes while the weight method was perhaps more accurate in describing stereoscopic void space for 3D structure devices. This article will give instructive clues for engineers to improve mesh structures, and better understanding of warp knitting meshes for surgeons.
Collapse
|
18
|
Mesh in laparoscopic large hiatal hernia repair: a systematic review of the literature. Surg Endosc 2013; 27:3998-4008. [PMID: 23793804 DOI: 10.1007/s00464-013-3036-y] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2013] [Accepted: 05/17/2013] [Indexed: 12/11/2022]
Abstract
BACKGROUND The use of mesh is becoming more popular for large hiatal hernia (type II-IV) repair to reduce the recurrence rate. The aim of this study was to outline the currently available literature on the use of mesh in laparoscopic large hiatal hernia repair, emphasizing objective outcome. METHODS A structured search of the literature was performed in the Medline, Embase, and Cochrane Central Register of Controlled Trials databases. RESULTS A total of 26 studies met the inclusion criteria. There were three randomized controlled trials, seven prospective and five retrospective cohort studies, and five prospective and one retrospective case-control study. The study design was not reported in the remaining studies. In the included studies, laparoscopic hiatal hernia repair was performed with mesh in 924 patients (mesh group) and without mesh in 340 patients (nonmesh group). The type of mesh used was very different: polypropylene in six, biomesh in nine, polytetrafluoroethylene (PTFE) in two, expanded PTFE (ePTFE) in two, and composite polypropylene-PTFE in another two. At least two different kinds of mesh were used in five studies. Radiological and/or endoscopic follow-up was performed after a mean (± SEM) period of 25.2 ± 4.0 months. There was no or only a small recurrence (recurrent hiatal hernia <2 cm) in 385 of the 451 available patients (85.4 %) in the mesh group and in 182 of 247 (73.7 %) in the nonmesh group. CONCLUSIONS The use of mesh in the repair of large hiatal hernias is promising with respect to the reduction of anatomical recurrences. However, many different kinds and configurations of mesh are available. This systematic review of the literature is a basis for high-quality randomized controlled trials to obtain the most effective and safe mesh in the long term.
Collapse
|
19
|
|
20
|
Massullo JM, Singh TP, Dunnican WJ, Binetti BR. Preliminary study of hiatal hernia repair using polyglycolic acid: trimethylene carbonate mesh. JSLS 2012; 16:55-9. [PMID: 22906331 PMCID: PMC3407458 DOI: 10.4293/108680812x13291597715943] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorporating primary crural repair with onlay fixation of a synthetic polyglycolicacid:trimethylene carbonate (PGA:TMC) absorbable tissue reinforcement. The purpose of this report is to present short-term follow-up data. METHODS Patients with hiatal hernia types I-III and defects >5cm were included. Primary closure of the hernia defect was performed using interrupted nonpledgeted sutures, followed by PGA:TMC mesh onlay fixed with absorbable tacks. A fundoplication was then performed. Evaluation of patients was carried out at routine follow-up visits. Outcomes measured were symptoms of gastroesophageal reflux disease (GERD), or other symptoms suspicious for recurrence. Patients exhibiting these complaints underwent further evaluation including radiographic imaging and endoscopy. RESULTS Follow-up data were analyzed on 11 patients. Two patients were male; 9 were female. The mean age was 60 years. The mean length of follow-up was 13 months. There were no complications related to the mesh. One patient suffered from respiratory failure, one from gas bloat syndrome, and another had a superficial port-site infection. One patient developed a recurrent hiatal hernia. CONCLUSIONS In this small series, laparoscopic repair of hiatal hernias >5cm with onlay fixation of PGA:TMC tissue reinforcement has short-term outcomes with a reasonably low recurrence rate. However, due to the preliminary and nonrandomized nature of the data, no strong comparison can be made with other types of mesh repairs. Additional data collection is warranted.
Collapse
Affiliation(s)
- James M Massullo
- Department of General Surgery, Albany Medical Center, Albany, NY, USA.
| | | | | | | |
Collapse
|
21
|
Gibson SC, Wong SK, Dixon AC, Falk GL. Laparoscopic repair of giant hiatus hernia: prosthesis is not required for successful outcome. Surg Endosc 2012; 27:618-23. [DOI: 10.1007/s00464-012-2501-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Accepted: 07/09/2012] [Indexed: 11/28/2022]
|
22
|
Moreno-Egea A, Sanchez-Elduayen M, Parlorio De Andres E, Carrillo-Alcaraz A. Is Muscular Atrophy a Contraindication in Laparoscopic Abdominal Wall Defect Repair? A Prospective Study. Am Surg 2012. [DOI: 10.1177/000313481207800235] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Laparoscopic surgery for abdominal wall hernias improves short-term results as compared with open hernia surgery. However, no evidence exists to recommend this approach for pseudohernias, which are abdominal wall defects postsurgery caused by denervation and muscular atrophy. The purpose of this study is to analyze whether the laparoscopic approach benefits patients with a pseudohernia. A prospective nonrandomized, single-center clinical study was conducted of 24 patients operated on for pseudohernia. This study was designed with the basic principle of one unit, one surgeon, one mesh, and two techniques (laparoscopic or open double prosthetic repair). The primary end point was assessment of the abdominal wall according to: 1) abdominal perimeter; 2) computed tomography scan; and 3) degree of satisfaction. The secondary end points were intraoperative parameters and comorbidity. Laparoscopy offered no benefits in patients with pseudohernias. Open surgery offered no significant differences in intra- and postoperative morbidity, but if the initial weakness improved with a decrease in abdominal perimeter and visceral content, then there was more than 90 per cent satisfaction ( P < 0.05). The laparoscopic approach does not improve the bulge caused by abdominal muscle atrophy. The option of a muscular and prosthetic reconstruction provides better clinical and cosmetic results.
Collapse
Affiliation(s)
- Alfredo Moreno-Egea
- Departments of Surgery Abdominal Wall Unit, J.M. Morales Meseguer University Hospital, University of Murcia, Faculty of Medicine, Murcia, Spain
| | - Maite Sanchez-Elduayen
- Anesthesia, Abdominal Wall Unit, J.M. Morales Meseguer University Hospital, University of Murcia, Faculty of Medicine, Murcia, Spain
| | - Elena Parlorio De Andres
- Radiology, Abdominal Wall Unit, J.M. Morales Meseguer University Hospital, University of Murcia, Faculty of Medicine, Murcia, Spain
| | - Andres Carrillo-Alcaraz
- Departments of Surgery Abdominal Wall Unit, J.M. Morales Meseguer University Hospital, University of Murcia, Faculty of Medicine, Murcia, Spain
| |
Collapse
|
23
|
Giant hiatal hernias: direct hiatus closure has an acceptable recurrence rate. Updates Surg 2011; 63:75-81. [PMID: 21479718 DOI: 10.1007/s13304-011-0066-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2011] [Accepted: 03/14/2011] [Indexed: 12/21/2022]
Abstract
The purpose of this retrospective study was to analyze our results after laparoscopic repair of giant hiatal hernias with direct closure of the hiatus, since the reports document a radiological recurrence rate as high as 42%. Various studies have shown that laparoscopic hernia repair is safe and effective, and carries a lower morbidity than the open approach, but the high recurrence rates still being reported (ranging from 10 to 42%) have prompted many authors to recommend using a prosthesis. This is a report on the follow-up of 38 patients with type III and IV hiatal hernia who underwent laparoscopic repair with direct hiatal closure without the aid of meshes. From January 2000 to March 2010, 38 patients with III and IV hiatal hernia were treated at the Surgery Division of Cisanello Hospital in Pisa. Data were collected retrospectively and included demographics, preoperative symptoms, radiographic and endoscopic findings, intraoperative and postoperative complications, postoperative symptoms, barium X-ray and follow-up by medical examination and symptoms questionnaire. The sample included 12 males and 26 females, between 36 and 83 years (median age 62) with 26 type III (68.4%) and 12 type IV (31.6%) hernias. There were no conversions to laparotomy and no intraoperative or postoperative mortality. A 360° Nissen fundoplication was performed in 22 patients (57.9%) and a 270° Toupet fundoplication in 16 patients (42.1%). One patient had intraoperative complications (2.6%), and postoperative complications occurred in another three (7.9%). The follow-up was complete in all patients and ranged from 12 to 88 months (median 49 months). Barium swallow was performed in all patients and recurrence was found in five patients (13.1%); three of these patients (7.9%) were asymptomatic, while two (5.2%) were reoperated. All 38 patients' symptoms improved. Judging from our data, the recurrence rate after laparoscopic giant hiatal hernia repair with direct hiatal closure can be lowered by complying with several crucial surgical principles, e.g., complete sac excision and appropriate crural closure, adequate esophageal lengthening, and the addition of an antireflux procedure and a gastropexy. We recorded a radiological recurrence rate of 13.1% (5/38) and patient satisfaction in our series was quite high (92%). Based on these findings, the laparoscopic treatment of giant hernias with direct hiatal closure seems to be a safe and effective procedure.
Collapse
|
24
|
Zehetner J, Demeester SR, Ayazi S, Kilday P, Augustin F, Hagen JA, Lipham JC, Sohn HJ, Demeester TR. Laparoscopic versus open repair of paraesophageal hernia: the second decade. J Am Coll Surg 2011; 212:813-20. [PMID: 21435915 DOI: 10.1016/j.jamcollsurg.2011.01.060] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2010] [Revised: 01/18/2011] [Accepted: 01/26/2011] [Indexed: 12/23/2022]
Abstract
BACKGROUND A decade ago we reported that laparoscopic repair of paraesophageal hernia (PEH) had an objective recurrence rate of 42% compared with 15% after open repair. Since that report we have modified our laparoscopic technique. The aim of this study was to determine if these modifications have reduced the rate of objective hernia recurrence. STUDY DESIGN We retrospectively identified all patients that had primary repair of a PEH with ≥ 50% of the stomach in the chest from May 1998 to January 2010 with objective follow-up by videoesophagram. The finding of any size of hernia was considered to be recurrence. RESULTS There were 73 laparoscopic and 73 open PEH repairs that met the study criteria. There were no significant differences in gender, body mass index, or prevalence of a comorbid condition between groups. The median follow-up was similar (12 months laparoscopic versus 16 months open; p = 0.11). In the laparoscopic group, 84% of patients had absorbable mesh reinforcement of the crural closure and 40% had a Collis gastroplasty, compared with 32% and 26%, respectively, in the open group. A recurrent hernia was identified in 27 patients (18%), 9 after laparoscopic repair and 18 after open repair (p = 0.09). The median size of a recurrent hernia was 3 cm, and the incidence of recurrence increased yearly in those with serial follow-up with no early peak or late plateau. CONCLUSIONS In our first decade of laparoscopic PEH repair, no mesh crural reinforcement was used, and no patient had a Collis gastroplasty. Evolution in the technique of laparoscopic PEH repair during the subsequent decade has reduced the hernia recurrence rate to that seen with an open approach. Reduced morbidity and shorter hospital stay make laparoscopy the preferred approach, but continued efforts to reduce hernia recurrence are warranted.
Collapse
Affiliation(s)
- Jörg Zehetner
- Department of Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Moreno-Egea A, Aguayo-Albasini JL. [Historic analysis of complex incisional hernia: to an understanding of the double prosthetic repair technique]. Cir Esp 2010; 88:292-8. [PMID: 20705285 DOI: 10.1016/j.ciresp.2010.05.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2010] [Revised: 04/13/2010] [Accepted: 05/01/2010] [Indexed: 11/26/2022]
Abstract
The treatment of complex incisional hernias is, on occasions, a real social and professional, and still controversial, challenge. A multitude of techniques have been described over the years in an attempt to solve this problem. The social context and technological development of each period are essential to understand the continuous changes in the way of performing these techniques. This article caries out an historical review of the prosthetic treatment of incisional hernias, trying to understand and apply the basic principles of the treatment of all incisional hernias to the repair with a double mesh.
Collapse
Affiliation(s)
- Alfredo Moreno-Egea
- Unidad de Cirugía de la Pared Abdominal, Departamento de Cirugía, Hospital Morales Meseguer, Murcia, España.
| | | |
Collapse
|
26
|
Zehetner J, Lipham JC, Ayazi S, Oezcelik A, Abate E, Chen W, Demeester SR, Sohn HJ, Banki F, Hagen JA, Dickey M, Demeester TR. A simplified technique for intrathoracic stomach repair: laparoscopic fundoplication with Vicryl mesh and BioGlue crural reinforcement. Surg Endosc 2009; 24:675-9. [PMID: 19690911 DOI: 10.1007/s00464-009-0662-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2009] [Revised: 06/24/2009] [Accepted: 07/16/2009] [Indexed: 12/18/2022]
Abstract
BACKGROUND Laparoscopic repair of an intrathoracic stomach has been associated with a high recurrence rate. The use of biologic or synthetic mesh to reinforce the crural repair has been shown to reduce recurrence. This study aimed to assess a simplified technique for reinforcing the crural repair using absorbable Vicryl mesh secured with BioGlue during laparoscopic repair of an intrathoracic stomach. METHODS The charts of all patients who underwent laparoscopic repair of an intrathoracic stomach from June 2006 to March 2009 using the described technique were retrospectively reviewed. Intrathoracic stomach was defined as more than 50% of the stomach herniated into the chest. Follow-up assessment was routinely performed 1 year or more after surgery and included endoscopy, video esophagram, Bravo 48-h pH monitoring, and a gastroesophageal reflux disease (GERD)-health-related quality-of-life (HRQL) questionnaire. RESULTS A total of 35 patients (male:female = 10:25) with a mean age of 70 years (48-89 years) and a mean body mass index (BMI) of 30.4 kg/m(2) (20.4-44.8 kg/m(2)) underwent repair using this technique. The median operating time was 144 min (101-311 min), and the median hospital stay was 2 days (1-21 days). There were three conversions (8.6%) and one intraoperative complication (2.9%). Three patients (8.6%) experienced postoperative complications. No mesh-related complications occurred. Follow-up assessment 1 year or more after surgery was available for 21 of the 25 eligible patients [median follow-up period, 14 months (11-34 months)]. There were two recurrences (9.5%), one of them asymptomatic. The median GERD-HRQL score was 5 (2-28). Nearly all the patients (91.3%) were satisfied with the operation, and 96% would have it again. CONCLUSION Vicryl mesh secured with BioGlue is a simple and easy method for reinforcing the crural closure during laparoscopic repair of an intrathoracic stomach. The recurrence rate at 1 year is low and comparable with that of other series using biologic mesh secured with sutures or tacks.
Collapse
Affiliation(s)
- Jörg Zehetner
- Department of Surgery, Keck School of Medicine, University of Southern California, 1510 San Pablo Street, Suite 514, Los Angeles, CA 90033, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Fortelny RH, Petter-Puchner AH, Glaser KS, Keibl C, Gruber-Blum S, Ohlinger W, Redl H. Fibrin sealant (Tisseel) for hiatal mesh fixation in an experimental model in pigs. J Surg Res 2009; 162:68-74. [PMID: 19815234 DOI: 10.1016/j.jss.2009.06.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2008] [Revised: 05/21/2009] [Accepted: 06/08/2009] [Indexed: 01/28/2023]
Abstract
BACKGROUND This study was designed to assess the efficacy of the fibrin sealant fixation of titanized polypropylene mesh in experimental hiatal mesh closure in pigs. Prosthetic hiatal closure is recommended for the repair of large hiatal/paraesophageal hernias as well as for antireflux surgery. However, only limited data exist on the favorable choice of meshes and fixation devices. Migration of the implant and trauma to neighboring organs due to perforating devices, such as sutures or tacks, present potentially lethal complications. In this study, we propose the fixation of titanized polypropylene meshes (TS) specifically developed for hiatal closure (TISure; GfE Medizintechnik GmbH, Nuremberg, Germany) with human fibrin sealant (FS, Tisseel; Baxter Biosciences, Vienna, Austria). MATERIALS AND METHODS A laparotomy was carried out in 7 mini-pigs (27-30 kg bodyweight) under general anaesthesia, and a TS was implanted after precise dissection of the right and left crura and the crural commissure. The key hole of the TS was placed around the esophagus at the gastroesophageal junction. One mL of FS was applied with the Easy Spray system (Baxter Biosciences, Vienna, Austria) for circular and three dimensional mesh fixation onto the diaphragm. Due to the lack of accepted gold standards of hiatal mesh reinforcement, no control group was used. Animals were sacrificed after 4 wk, and meshes were explanted after macroscopical assessment of the correct position and tissue integration. Histology was performed. RESULTS All meshes showed excellent tissue integration and no signs of migration or dislocation. FS was completely degraded and replaced by well vascularized fibroblastic tissue. CONCLUSIONS Titanized polypropylene mesh with FS fixation was found to be a safe and efficient combination for reinforcement of the hiatal closure in this preliminary experimental model.
Collapse
Affiliation(s)
- René H Fortelny
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology and Cluster for Tissue Regeneration, Vienna, Austria
| | | | | | | | | | | | | |
Collapse
|
28
|
Omission of the calibration bougie in laparoscopic repair of paraesophageal hernia. Surg Endosc 2009; 23:2505-8. [DOI: 10.1007/s00464-009-0426-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2008] [Revised: 01/09/2009] [Accepted: 02/16/2009] [Indexed: 01/09/2023]
|