1
|
Alkhatib H, Haas AJ, Kara AM, Lai C, Feria A, Bardaro S, Dorsey A, El-Hayek K. Tailoring the wrap: intraoperative functional lumen imaging probe (FLIP) during hiatal hernia repair. Surg Endosc 2024; 38:3425-3432. [PMID: 38722379 PMCID: PMC11133156 DOI: 10.1007/s00464-024-10851-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 04/10/2024] [Indexed: 05/30/2024]
Abstract
INTRODUCTION The introduction of the functional lumen imaging probe (FLIP) has provided objective, real-time feedback on the geometric variations with each component of a hiatal hernia repair (HHR). The utility of this technology in altering intraoperative decision-making has been scarcely reported. Herein, we report a single-center series of intraoperative FLIP during HHR. METHODS A retrospective review of electronic medical records between 2020 and 2022 was conducted and all patients undergoing non-recurrent HHR with FLIP were queried. Patient and hernia characteristics, intraoperative FLIP values and changes in decision-making, as well as early post-operative outcomes were reported. Both diameter and distensibility index (DI) were measured at 40 ml and 50 ml balloon inflation after hiatal dissection, after hiatal closure, and after fundoplication when indicated. RESULTS Thirty-three patients met inclusion criteria. Mean age was 62 ± 14 years and mean BMI was 28 ± 6 kg/m2. The majority (53%) were type I hiatal hernias. The largest drop in DI occurred after hiatal closure, with minimal change seen after fundoplication (mean DI of 4.3 ± 2. after completion of HH dissection, vs 2.7 ± 1.2 after hiatal closure and 2.3 ± 1 after fundoplication when performed). In 13 (39%) of cases, FLIP values directly impacted intraoperative decision-making. Fundoplication was deferred in 4/13 (31%) patients, the wrap was loosened in 2/13 (15%); the type of fundoplication was altered to achieve adequate anti-reflux values in 2/13 (15%) patients, and in 1/13 (3%) the wrap was tightened. CONCLUSION FLIP measurements can be used intraoperatively to guide decision-making and alter management plan based on objective values. Long-term outcomes and further prospective studies are required to better delineate the value of this technology.
Collapse
Affiliation(s)
- Hemasat Alkhatib
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA.
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA.
| | - A J Haas
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA
| | - Ali M Kara
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA
| | - Clara Lai
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA
| | - Alejandro Feria
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA
| | - Sergio Bardaro
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA
| | - Amelia Dorsey
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA
| | - Kevin El-Hayek
- Division of General Surgery, Department of Surgery, The MetroHealth System, 2500 MetroHealth Drive, Cleveland, OH, 44109, USA
- Case Western Reserve University School of Medicine, 10900 Euclid Ave., Cleveland, OH, 44106, USA
| |
Collapse
|
2
|
Al Asadi H, Najah H, Edelmuth R, Greenberg JA, Marshall T, Salehi N, Lee YJ, Riascos MC, Finnerty BM, Fahey TJ, Zarnegar R. Impedance planimetry (EndoFLIPTM) and surgical outcomes after Hill compared to Toupet fundoplication. Surg Endosc 2024; 38:1020-1028. [PMID: 38097749 DOI: 10.1007/s00464-023-10640-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Accepted: 11/29/2023] [Indexed: 02/02/2024]
Abstract
INTRODUCTION Endoluminal functional lumen imaging probe (EndoFLIP) provides a real-time assessment of gastroesophageal junction (GEJ) compliance during fundoplication. Given the limited data on EndoFLIP measurements during the Hill procedure, we investigated the impact of the Hill procedure on GEJ compliance compared to Toupet fundoplication. METHODS Patients who underwent robotic Hill or Toupet fundoplication with intraoperative EndoFLIP between 2017 and 2022 were included. EndoFLIP measurements of the GEJ included cross sectional surface area (CSA), intra-balloon pressure, high pressure zone length (HPZ), distensibility index (DI), and compliance. Subjective reflux symptoms, gastroesophageal reflux disease-health related quality of life (GERD-HRQL) score, and dysphagia score were assessed pre-operatively as well as at short- and longer-term follow-up. RESULTS One-hundred and fifty-four patients (71.9%) had a Toupet fundoplication while sixty (28%) patients underwent the Hill procedure. The CSA [27.7 ± 10.9 mm2 vs 42.2 ± 17.8 mm2, p < 0.0001], pressure [29.5 ± 6.2 mmHg vs 33.9 ± 8.5 mmHg, p = 0.0009], DI [0.9 ± 0.4 mm2/mmHg vs 1.3 ± 0.6 mm2/mmHg, p = 0.001], and compliance [25.9 ± 12.8 mm3/mmHg vs 35.4 ± 13.4 mm3/mmHg, p = 0.01] were lower after the Hill procedure compared to Toupet. However, there was no difference in post-fundoplication HPZ between procedures [Hill: 2.9 ± 0.4 cm, Toupet: 3.1 ± 0.6 cm, p = 0.15]. Follow-up showed no significant differences in GERD-HRQL scores, overall dysphagia scores or atypical symptoms between groups (p > 0.05). CONCLUSION The Hill procedure is as effective to the Toupet fundoplication in surgically treating gastroesophageal reflux disease (GERD) despite the lower CSA, DI, and compliance after the Hill procedure. Both procedures led to DI < 2 mm2/mmHg with no significant differences in dysphagia reporting (12-24) months after the procedure. Further studies to elucidate a cutoff value for DI for postoperative dysphagia development are still warranted.
Collapse
Affiliation(s)
- Hala Al Asadi
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Haythem Najah
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | | | - Jacques A Greenberg
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Teagan Marshall
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Niloufar Salehi
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Yeon Joo Lee
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Maria Cristina Riascos
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Brendan M Finnerty
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Thomas J Fahey
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA
| | - Rasa Zarnegar
- Division of Endocrine & Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68 Street, K-836, New York, NY, 10065, USA.
| |
Collapse
|
3
|
Brunaldi VO, Abboud DM, Abusaleh RR, Al Annan K, Razzak FA, Ravi K, Valls EJV, Storm AC, Ghanem OM, Abu Dayyeh BK. Post-bariatric Surgery Changes in Secondary Esophageal Motility and Distensibility Parameters. Obes Surg 2024; 34:347-354. [PMID: 38123782 DOI: 10.1007/s11695-023-06959-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 11/10/2023] [Accepted: 11/13/2023] [Indexed: 12/23/2023]
Abstract
INTRODUCTION Despite the increasing number of bariatric procedures over the recent years, the physiological changes in secondary esophageal motility and distensibility parameters after surgery remain unknown. METHODS This is a retrospective, single-center cohort study comparing esophageal planimetry and gastroesophageal junction (GEJ) distensibility in post-bariatric surgery patients (Roux-en-Y gastric bypass (RYGB), sleeve gastrectomy (SG), and conversion/revisional patients (DH)) and native-anatomy patients with obesity (NAC). Distensibility refers to the area achieved with a certain amount of pressure, and secondary peristalsis represents the esophageal response to an intended obstruction. Patients with pre-surgical dysmotility symptoms were excluded from the study. RESULTS From November 2018 to January 2023, 167 patients were evaluated and eligible for this study (RYGB = 87, SG = 33, NAC = 22, DH = 25). In NAC cohort, 17/22 (77%) patients presented normal motility patterns compared to 35/87 (40%) RYGB, 12/33 (36%) SG, and 5/25 (20%) DH (p < 0.05 for all comparisons). The most common abnormal motility pattern for all three bariatric cohorts was absent contractions. DH patients generally had the highest mean maximum distensibility index averages, followed by SG, RYGB, and NAC. CONCLUSION Bariatric surgery affects esophageal and GEJ physiology, and it is associated with higher rates of secondary dysmotility. DH patients have even higher rates of dysmotility. Further studies assessing clinical data and their correlation with manometric and pH-metric findings are needed.
Collapse
Affiliation(s)
- Vitor Ottoboni Brunaldi
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
| | - Donna Maria Abboud
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Rami R Abusaleh
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Karim Al Annan
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Farah Abdul Razzak
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Karthik Ravi
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Eric J Vargas Valls
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Andrew C Storm
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | | | - Barham K Abu Dayyeh
- Gastroenterology and Hepatology Division, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| |
Collapse
|
4
|
Low EE, Yadlapati R. Utility of Functional Lumen Imaging Probe in the Evaluation of Esophageal Conditions. Am J Gastroenterol 2024; 119:15-20. [PMID: 37450632 PMCID: PMC10841715 DOI: 10.14309/ajg.0000000000002387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023]
Affiliation(s)
- Eric E. Low
- Division of Gastroenterology and Hepatology, University of California, San Diego, San Diego, California, USA
| | - Rena Yadlapati
- Division of Gastroenterology and Hepatology, University of California, San Diego, San Diego, California, USA
| |
Collapse
|
5
|
VanDruff VN, Amundson JR, Joseph S, Che S, Kuchta K, Zimmermann CJ, Ishii S, Hedberg HM, Ujiki MB. Impedance planimetry and panometry (EndoFLIP™) can replace manometry in preoperative anti-reflux surgery assessment. Surg Endosc 2024; 38:339-347. [PMID: 37770608 DOI: 10.1007/s00464-023-10419-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 08/29/2023] [Indexed: 09/30/2023]
Abstract
BACKGROUND Endoluminal functional impedance planimetry and panometry assesses secondary peristalsis in response to volumetric distention under sedation. We hypothesize that impedance planimetry and panometry can replace high-resolution manometry in the preoperative assessment prior to anti-reflux surgery. METHODS Single institution prospective data were collected from patients undergoing anti-reflux surgery between 2021 and 2023. A 16-cm functional luminal imaging probe (FLIP) assessed planimetry and panometry prior to surgery under general anesthesia at the start of each case. Panometry was recorded and esophageal contractile response was classified as normal (NCR), diminished or disordered (DDCR), or absent (ACR) in real time by a single panometry rater, blinded to preoperative HRM results. FLIP results were then compared to preoperative HRM. RESULTS Data were collected from 120 patients, 70.8% female, with mean age of 63 ± 3 years. There were 105 patients with intraoperative panometry, and 15 with panometry collected during preoperative endoscopy. There were 60 patients (50%) who had peristaltic dysfunction on HRM, of whom 57 had FLIP dysmotility (55 DDCR, 2 ACR) resulting in 95.0% sensitivity. There were 3 patients with normal secondary peristalsis on FLIP with abnormal HRM, all ineffective esophageal motility (IEM). No major motility disorder was missed by FLIP. A negative predictive value of 91.9% was calculated from 34/37 patients with normal FLIP panometry and normal HRM. Patients with normal HRM but abnormal FLIP had larger hernias compared to patients with concordant studies (7.5 ± 2.8 cm vs. 5.4 ± 3.2 cm, p = 0.043) and higher preoperative dysphagia scores (1.5 ± 0.7 vs. 1.1 ± 0.3, p = 0.021). CONCLUSION Impedance planimetry and panometry can assess motility under general anesthesia or sedation and is highly sensitive to peristaltic dysfunction. Panometry is a novel tool that has potential to streamline and improve patient care and therefore should be considered as an alternative to HRM, especially in patients in which HRM would be inaccessible or poorly tolerated.
Collapse
Affiliation(s)
- Vanessa N VanDruff
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA.
- Department of Surgery, University of Chicago, Chicago, IL, USA.
| | - Julia R Amundson
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
- Department of Surgery, University of Chicago, Chicago, IL, USA
| | - Stephanie Joseph
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Simon Che
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Kristine Kuchta
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Christopher J Zimmermann
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Shun Ishii
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - H Mason Hedberg
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Michael B Ujiki
- Department of Minimally Invasive Surgery, NorthShore University HealthSystem, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| |
Collapse
|
6
|
Vackova Z, Levenfus I, Pohl D. Interventional functional diagnostics in gastrointestinal endoscopy: Combining diagnostic and therapeutic tools in the endoscopy suite with the functional lumen imaging probe. Curr Opin Pharmacol 2023; 73:102414. [PMID: 38029641 DOI: 10.1016/j.coph.2023.102414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 10/18/2023] [Accepted: 11/03/2023] [Indexed: 12/01/2023]
Abstract
With technical progress of gastrointestinal functional testing, there has been a demand for more comprehensive examination of esophageal physiology and pathophysiology beyond high-resolution manometry. A new interventional technology based on impedance planimetry, the functional lumen imaging probe (FLIP), enables intraluminal measurement of distensibility and compliance of hollow organs. EndoFLIP uses balloon catheters to measure diameter and distension pressure to calculate cross-sectional area and distensibility in different organs (mostly esophagus, stomach, anorectal region) and can be used in wide variety of indications (diagnostics, pre- and post-treatment evaluation) and currently serves as a helpful adjunctive tool in ambiguous clinical cases. EsoFLIP is a therapeutic variation that uses a stiffer balloon catheter allowing for dilation. The trend to simplify the clinical process from diagnosis to treatment tends to a one-session procedure combining diagnostics and therapeutic interventions. In specified conditions like e.g. achalasia or gastroparesis, a combination of EndoFLIP and EsoFLIP procedures may therefore be useful. The aim of this narrative review is to introduce the clinical use of FLIP and its potential benefit in combined diagnostic-therapeutic procedures.
Collapse
Affiliation(s)
- Zuzana Vackova
- Department of Gastrointestinal Endoscopy, Department of Medicine, Military University Hospital Prague, Czech Republic.
| | - Ian Levenfus
- Division of Gastroenterology and Hepatology, University Hospital Zurich, Switzerland
| | - Daniel Pohl
- Division of Gastroenterology and Hepatology, University Hospital Zurich, Switzerland
| |
Collapse
|
7
|
Amundson JR, Kuchta K, Zimmermann CJ, VanDruff VN, Joseph S, Che S, Ishii S, Hedberg HM, Ujiki MB. Target distensibility index on impedance planimetry during fundoplication by choice of wrap and choice of bougie. Surg Endosc 2023; 37:8670-8681. [PMID: 37500920 DOI: 10.1007/s00464-023-10301-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 07/12/2023] [Indexed: 07/29/2023]
Abstract
INTRODUCTION Impedance planimetry (FLIP) provides objective feedback to optimize fundoplication outcomes. Ideal FLIP ranges for differing wraps and bougies have not yet been established. We report FLIP measurements during fundoplication grouped by choice of wrap and bougie with associated outcomes. METHODS A retrospective review of a prospective gastroesophageal database was performed for all Nissen or Toupet fundoplication with intraoperative FLIP using an 8-cm catheter, 30-mL and/or 40-mL fill and/or 16-cm catheter, 60-mL fill. Surgeons used no bougie, the FLIP balloon as bougie, or a hard bougie. Outcomes included perioperative data, Reflux Symptom Index, GERD-HRQL, Dysphagia scores, need for dilation, postoperative EGD findings, and hernia recurrence. Group comparisons were made using two-tailed Kruskal-Wallis and Fisher's exact tests. RESULTS Between 2016 and 2022, 333 patients underwent fundoplication and intraoperative FLIP. Procedures included Toupet with hard bougie (TFHB, N = 147), Toupet with FLIP bougie (TFFB, N = 69), Toupet without bougie (TFNB, N = 78), Nissen with hard bougie (NFHB, n = 20), or Nissen with FLIP bougie (NFFB, N = 19). FLIP measurements at 30-mL/40-mL fills varied significantly between groups, notably distensibility index at crural closure (CCDI) and post-fundoplication (FDI). No significant differences in FLIP measurements were seen between those who developed poor postoperative outcomes and those who did not, including when grouping by choice of wrap and bougie. At a 40-mL fill, abnormal motility patients with CCDI > 3.5 mm2/mmHg developed zero postoperative dysphagia. TFFB abnormal motility patients with CCDI > 3.5 mm2/mmHg or FDI > 3.6 mm2/mmHg developed zero postoperative dysphagia. CONCLUSION Intraoperative FLIP measurements vary by fundoplication and bougie choice. A CCDI > 3.5 mm2/mmHg (40 mL fill) should be sought in abnormal motility patients, regardless of wrap or bougie, to avoid postoperative dysphagia. TFFB abnormal motility patients with FDI > 3.6 mm2/mmHg (40 mL fill) also developed zero postoperative dysphagia. FDI > 6.2 mm2/mmHg (40 mL fill) was seen in all postoperative hernia recurrences.
Collapse
Affiliation(s)
- Julia R Amundson
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA.
- Department of Surgery, University of Chicago Medical Center, 5841 S. Maryland Ave, Chicago, IL, 60637, USA.
| | - Kristine Kuchta
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Christopher J Zimmermann
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Vanessa N VanDruff
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
- Department of Surgery, University of Chicago Medical Center, 5841 S. Maryland Ave, Chicago, IL, 60637, USA
| | - Stephanie Joseph
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Simon Che
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Shun Ishii
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - H Mason Hedberg
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Michael B Ujiki
- Department of Surgery, NorthShore University Health System, 2650 Ridge Avenue, GCSI Suite B665, Evanston, IL, 60201, USA
| |
Collapse
|
8
|
Low EE, Fehmi SA, Yadlapati R. Tailored myotomy for the treatment of type 3 achalasia: Is there a role for the functional lumen imaging probe? Neurogastroenterol Motil 2023; 35:e14670. [PMID: 37691561 PMCID: PMC10759927 DOI: 10.1111/nmo.14670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 08/21/2023] [Indexed: 09/12/2023]
Affiliation(s)
- Eric E Low
- Division of Gastroenterology, University of California, San Diego, San Diego, California, USA
| | - Syed A Fehmi
- Division of Gastroenterology, University of California, San Diego, San Diego, California, USA
| | - Rena Yadlapati
- Division of Gastroenterology, University of California, San Diego, San Diego, California, USA
| |
Collapse
|
9
|
Sillcox R, Carrera R, Wright AS, Oelschlager BK, Yates RB, Tatum RP. Esophageal Motility Patterns in Paraesophageal Hernia Patients Compared to Sliding Hiatal Hernia: Bigger Is Not Better. J Gastrointest Surg 2023; 27:2039-2044. [PMID: 37340102 DOI: 10.1007/s11605-023-05754-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 06/11/2023] [Indexed: 06/22/2023]
Abstract
BACKGROUND In patients with paraesophageal hernias (PEH), the course of the esophagus is often altered, which may affect esophageal motility. High-resolution manometry (HRM) is frequently used to evaluate esophageal motor function prior to PEH repair. This study was performed to characterize esophageal motility disorders in patients with PEH as compared to sliding hiatal hernia and to determine how these findings affect operative decision-making. METHODS Patients referred for HRM to a single institution from 2015 to 2019 were included in a prospectively maintained database. HRM studies were analyzed for the appearance of any esophageal motility disorder using the Chicago classification. PEH patients had confirmation of their diagnosis at the time of surgery, and the type of fundoplication performed was recorded. They were case-matched based on sex, age, and BMI to patients with sliding hiatal hernia who were referred for HRM in the same period. RESULTS There were 306 patients diagnosed with a PEH who underwent repair. When compared to case-matched sliding hiatal hernia patients, PEH patients had higher rates of ineffective esophageal motility (IEM) (p<.001) and lower rates of absent peristalsis (p=.048). Of those with ineffective motility (n=70), 41 (59%) had a partial or no fundoplication performed during PEH repair. CONCLUSION PEH patients had higher rates of IEM compared to controls, possibly due to a chronically distorted esophageal lumen. Offering the appropriate operation hinges on understanding the involved anatomy and esophageal function of each individual. HRM is important to obtain preoperatively for optimizing patient and procedure selection in PEH repair.
Collapse
Affiliation(s)
- Rachel Sillcox
- Department of Surgery, University of Washington, 1959 NE Pacific St, Seattle, WA, 98195, USA.
| | - Rocio Carrera
- Department of Surgery, University of Washington, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Andrew S Wright
- Department of Surgery, University of Washington, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Brant K Oelschlager
- Department of Surgery, University of Washington, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Robert B Yates
- Department of Surgery, University of Washington, 1959 NE Pacific St, Seattle, WA, 98195, USA
| | - Roger P Tatum
- Department of Surgery, University of Washington, 1959 NE Pacific St, Seattle, WA, 98195, USA
- Department of Surgery, VA Puget Sound HCS, University of Washington, Seattle, WA, USA
| |
Collapse
|
10
|
Amundson JR, Kuchta K, VanDruff VN, Wu H, Campbell M, Hedberg HM, Ujiki MB. Experience with Impedance Planimetry for Surgical Foregut Disease in 1,097 Cases. J Am Coll Surg 2023; 237:35-48. [PMID: 36896984 DOI: 10.1097/xcs.0000000000000675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
BACKGROUND The geometry and compliance of gastrointestinal sphincters may be assessed by impedance planimetry using a functional lumen imaging probe (FLIP). We describe our institutional foregut surgeon experience using FLIP in 1,097 cases, highlighting instances where FLIP changed operative decision making. STUDY DESIGN A retrospective review of an IRB-approved prospective quality database was performed. This included operative and endoscopic suite foregut procedures using FLIP between February 2013 and May 2022. RESULTS During the study period, FLIP was used a total of 1,097 times in 919 unique patients by 2 foregut surgeons. Intraoperative FLIP was used during 573 antireflux procedures and 272 endoscopic myotomies. FLIP was also used during 252 endoscopic suite procedures. For those undergoing preoperative workup of GERD, starting in 2021, esophageal panometry was performed in addition to standard FLIP measurements at the lower esophageal sphincter. In 77 cases, intraoperative FLIP changed operative decision making. During antireflux procedures, changes included adding or removing crural sutures, adjusting a fundoplication tightness, choice of full vs partial wrap, and magnetic sphincter augmentation sizing. For endoscopic procedures, changes included aborting peroral endoscopic myotomy or Zenker's peroral endoscopic myotomy, performing a myotomy when preoperative diagnosis was unclear, or performing additional myotomy. CONCLUSIONS FLIP is a useful tool for assessing the upper esophageal sphincter, lower esophageal sphincter, pylorus, and secondary esophageal peristalsis that can be used in a wide variety of clinical situations within a foregut surgeon's practice. It can also function as an adjunct in intraoperative decision making.
Collapse
Affiliation(s)
- Julia R Amundson
- From the Department of Surgery, University of Chicago, Chicago, IL (Amundson, VanDruff, Wu, Campbell)
- the Department of Surgery, NorthShore University Health System, Evanston, IL (Amundson, Kuchta, VanDruff, Wu, Campbell, Hedburg, Ujiki)
| | - Kristine Kuchta
- the Department of Surgery, NorthShore University Health System, Evanston, IL (Amundson, Kuchta, VanDruff, Wu, Campbell, Hedburg, Ujiki)
| | - Vanessa N VanDruff
- From the Department of Surgery, University of Chicago, Chicago, IL (Amundson, VanDruff, Wu, Campbell)
- the Department of Surgery, NorthShore University Health System, Evanston, IL (Amundson, Kuchta, VanDruff, Wu, Campbell, Hedburg, Ujiki)
| | - Hoover Wu
- From the Department of Surgery, University of Chicago, Chicago, IL (Amundson, VanDruff, Wu, Campbell)
- the Department of Surgery, NorthShore University Health System, Evanston, IL (Amundson, Kuchta, VanDruff, Wu, Campbell, Hedburg, Ujiki)
| | - Michelle Campbell
- From the Department of Surgery, University of Chicago, Chicago, IL (Amundson, VanDruff, Wu, Campbell)
- the Department of Surgery, NorthShore University Health System, Evanston, IL (Amundson, Kuchta, VanDruff, Wu, Campbell, Hedburg, Ujiki)
| | - H Mason Hedberg
- the Department of Surgery, NorthShore University Health System, Evanston, IL (Amundson, Kuchta, VanDruff, Wu, Campbell, Hedburg, Ujiki)
| | - Michael B Ujiki
- the Department of Surgery, NorthShore University Health System, Evanston, IL (Amundson, Kuchta, VanDruff, Wu, Campbell, Hedburg, Ujiki)
| |
Collapse
|
11
|
Layne SJ, Lorsch ZS, Patel A. Novel Diagnostic Techniques in the Evaluation of Gastroesophageal Reflux Disease (GERD). Dig Dis Sci 2023; 68:2226-2236. [PMID: 37071244 DOI: 10.1007/s10620-023-07901-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Accepted: 02/21/2023] [Indexed: 04/19/2023]
Abstract
In our present clinical paradigm, patient symptoms and presentation in the setting of traditional findings from endoscopy (erosive esophagitis, Barrett's esophagus, reflux-mediated stenosis), esophageal high-resolution manometry, and/or ambulatory reflux monitoring (distal esophageal acid exposure time, numbers of reflux events, reflux-symptom association) guide the care of patients with suspected GERD. However, novel metrics and techniques acquired from or performed at endoscopy, manometry, or pH-impedance monitoring, beyond conventional evaluation, are of great interest to the gastroenterology community given the frequent (and sometimes challenging) presentation of suspected GERD. These novel and evolving diagnostic approaches have the potential to enhance the evaluation of these patients and optimize their management. In this invited review, we discuss the present evidence and potential clinical utility of selected GERD metrics and techniques of interest at endoscopy (dilated intercellular spaces, mucosal impedance), manometry (contractile integral, impedance analysis, straight leg raise, multiple rapid swallow maneuvers), and reflux monitoring (mean nocturnal baseline impedance, post-reflux swallow-induced peristaltic wave indices), and how these tools may be most optimally adopted and utilized for clinical care (Fig. 1).
Collapse
Affiliation(s)
- Sabrina J Layne
- Division of Gastroenterology, Duke University School of Medicine, Durham, NC, USA
| | - Zachary S Lorsch
- Division of Gastroenterology, Duke University School of Medicine, Durham, NC, USA
| | - Amit Patel
- Division of Gastroenterology, Duke University School of Medicine and the Durham Veterans Affairs Medical Center, Box 3913, Durham, NC, 27710, USA.
| |
Collapse
|
12
|
Wu H, Ungerleider S, Campbell M, Amundson JR, VanDruff V, Kuchta K, Hedberg HM, Ujiki MB. Patient-reported outcomes in 645 patients after laparoscopic fundoplication up to 10 years. Surgery 2023; 173:710-717. [PMID: 36307333 DOI: 10.1016/j.surg.2022.07.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 07/02/2022] [Accepted: 07/22/2022] [Indexed: 11/07/2022]
Abstract
BACKGROUND Laparoscopic fundoplication is the gold-standard surgical management for gastroesophageal reflux disease. Optimal patient outcomes include resolution of symptoms with minimal postoperative side effects of dysphagia or gas-bloat. This study aims to review outcomes at a single institution up to 10 years after surgery. METHODS This is a retrospective review of a prospectively maintained quality database. Patients who underwent laparoscopic fundoplication from 2009 to 2021 were included. Transition in surgical practice mid-2017 with incorporation of fundoplication algorithm and impedance planimetry. Patient-reported outcome scores include Reflux Symptom Index, gastroesophageal reflux disease-health-related quality of life, and dysphagia score. Comparisons were made using two-tailed Wilcoxon rank sum tests. RESULTS Six hundred forty-five patients underwent laparoscopic fundoplication (2009-July 2017 n = 355, July 2017-November 2021 n = 290) from January 2009 to November 2021. Patients had an improvement in patient-reported outcomes and did not worsen from 2 to 10 years after surgery. Comparison of each time period showed that the second time period had fewer gas-bloat symptoms at 2 years (P = .04). Paraesophageal hernia was present in 66% of patients. Preoperative patient-reported outcomes in non-paraesophageal hernia include worse Reflux Symptoms Index (P < .01) and gastroesophageal reflux disease-health-related quality of life (P < .01) than the paraesophageal hernia group. Patient-reported outcomes were similar between the 2 except for worse gas-bloat in non-paraesophageal hernia patients at 2 years (P = .02). Endoscopy was performed in 10.9% (n = 58) of the study population at a median of 16 months, with 1.5% of patients (n = 8) from the entire cohort with abnormal DeMeester Scores. Median (interquartile range) preoperative DeMeester Score of 31 (17-51) decreased to 5 (2-14) at postoperative evaluation. CONCLUSION This single-institution study reports excellent long-term patient-reported outcomes after laparoscopic fundoplication that persist up to 10 years.
Collapse
Affiliation(s)
- Hoover Wu
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL.
| | | | - Michelle Campbell
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL
| | - Julia R Amundson
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL
| | - Vanessa VanDruff
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL
| | | | - Herbert M Hedberg
- Department of Surgery, NorthShore University Health System, Evanston, IL
| | - Michael B Ujiki
- Department of Surgery, NorthShore University Health System, Evanston, IL
| |
Collapse
|
13
|
Greenberg JA, Palacardo F, Edelmuth RCL, Egan CE, Lee YJ, Dakin G, Zarnegar R, Afaneh C, Bellorin O. Quantifying physiologic parameters of the gastroesophageal junction during robotic sleeve gastrectomy and identifying predictors of post-sleeve gastroesophageal reflux disease. Surg Endosc 2023; 37:1543-1550. [PMID: 35859010 DOI: 10.1007/s00464-022-09450-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 07/05/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND Sleeve gastrectomy is among the most commonly-performed procedures for morbid obesity. However, patients occasionally develop post-sleeve gastroesophageal reflux disease (GERD). Identifying patients most at risk for this complication remains difficult. We aimed to correlate intra-operative physiologic measurements of the lower esophageal sphincter (LES) at the gastroesophageal junction (GEJ) during robotic sleeve gastrectomy in an attempt to identify predictors of post-sleeve GERD symptoms. METHODS A retrospective chart review of a prospectively maintained database identified 28 patients in whom robotic sleeve gastrectomy was performed utilizing EndoFLIP™ technology between January and September 2021. Intraoperative LES measurements at the GEJ including cross-sectional area (CSA), distensibility index (DI), intra-balloon pressure, and high-pressure zone (HPZ length) were correlated with post-operative GERD. RESULTS GEJ CSA, pressure, and DI increased over the course of the surgery (CSA pre-op: 31 (IQR 19.3-39.5) mm2 vs. post-op: 67 (IQR 40.8-95.8) mm2, p < 0.001; pressure: 25.8 (IQR 20.2-33.1) mmHg vs. 31.5 (IQR 28.9-37.0) mmHg, p = 0.007; DI 1.1 (IQR 0.8-1.8) mm2/mmHg vs. 2.0 (IQR 1.2-3.0) mm2/mmHg, p = < 0.001), whereas HPZ length decreased (2.5 (IQR 2.5-3) cm vs. 2.0 (IQR 1.3-2.5) cm, p = 0.022). Twenty-three patients (82.1%) completed a post-operative GERD questionnaire. Fifteen (65.2%) had no GERD symptoms before or after surgery; 5 (21.7%) reported new post-sleeve GERD symptoms; 3 (13.0%) reported exacerbation of pre-existing GERD symptoms. Patients with new or worsening GERD symptoms had higher post-sleeve DIs (3.2 (IQR 1.9-4.5) mm2/mmHg vs. 1.5 (IQR 1.2-2.4) mm2/mmHg, p = 0.024) and lower post-sleeve LES pressures (29.9 (IQR 26.3-32.9) mmHg vs. 35.2 (IQR 31.0-38.0) mmHg, p = 0.023) than those without. CONCLUSIONS An increase in GEJ CSA, pressure, and DI, and a decrease in GEJ length can be expected during robotic sleeve gastrectomy. Patients with new or worsening post-sleeve GERD symptoms have higher post-sleeve DI and lower post-sleeve LES pressure than their asymptomatic counterparts.
Collapse
Affiliation(s)
- Jacques A Greenberg
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Federico Palacardo
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Rodrigo C L Edelmuth
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Caitlin E Egan
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Yeon Joo Lee
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Gregory Dakin
- Department of Surgery, Division of Gastrointestinal Metabolic & Bariatric Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 520 East 70th Street, Starr Pavillion, 8th Floor, New York, NY, 10021, USA
| | - Rasa Zarnegar
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Cheguevara Afaneh
- Department of Surgery, Division of Gastrointestinal Metabolic & Bariatric Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 520 East 70th Street, Starr Pavillion, 8th Floor, New York, NY, 10021, USA
| | - Omar Bellorin
- Department of Surgery, Division of Gastrointestinal Metabolic & Bariatric Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 520 East 70th Street, Starr Pavillion, 8th Floor, New York, NY, 10021, USA.
| |
Collapse
|
14
|
Froiio C, Tareq A, Riggio V, Siboni S, Bonavina L. Real-world evidence with magnetic sphincter augmentation for gastroesophageal reflux disease: a scoping review. Eur Surg 2023. [DOI: 10.1007/s10353-022-00789-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Summary
Background
The burden of gastroesophageal reflux disease (GERD) is high, with up to 30% of the Western population reporting reflux-related symptoms with or without hiatal hernia. Magnetic sphincter augmentation (MSA) is a standardized laparoscopic procedure for patients who are dissatisfied with medical therapy and for those with early-stage disease who would not usually be considered ideal candidates for fundoplication. The MSA device is manufactured in different sizes and is designed to augment the physiologic barrier to reflux by magnetic force.
Methods
An extensive scoping review was performed to provide a map of current evidence with respect to MSA, to identify gaps in knowledge, and to make recommendations for future research. All the authors contributed to the literature search in PubMed and Web of Science and contributed to summarizing the evidence.
Results
Magnetic sphincter augmentation, especially in combination with crural repair, is effective in reducing GERD symptoms, proton pump inhibitor use, and esophageal acid exposure, and in improving patients’ quality of life. Safety issues such as device erosion or migration have been rare and not associated with mortality. The MSA device can be removed laparoscopically if necessary, thereby preserving the option of fundoplication or other therapies in the future. Contraindication to scanning in high-power Tesla magnetic resonance systems remains a potential limitation of the MSA procedure. High-resolution manometry and functional lumen imaging probes appear to be promising tools to predict procedural outcomes by improving reflux control and reducing the incidence of dysphagia.
Conclusion
A consensus on acquisition and interpretation of high-resolution manometry and impedance planimetry data is needed to gain better understanding of physiology, to improve patient selection, and to pave the way for a personalized surgical approach in antireflux surgery.
Collapse
|
15
|
Wu H, Attaar M, Wong HJ, Campbell M, Kuchta K, Denham W, Linn J, Ujiki MB. Impedance planimetry (EndoFLIP™) reveals changes in gastroesophageal junction compliance during fundoplication. Surg Endosc 2022; 36:6801-6808. [PMID: 35015103 DOI: 10.1007/s00464-021-08966-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 12/12/2021] [Indexed: 10/19/2022]
Abstract
INTRODUCTION Compliance is the ability of a hollow organ to dilate and increase volume with an increase in pressure, an accurate representation of food bolus transit through the gastroesophageal junction (GEJ). Impedance planimetry system can calculate compliance (change in volume over pressure) and distensibility (cross-sectional area over pressure) of the GEJ. We aim to describe the changes in compliance during anti-reflux surgery and hypothesize that compliance is a better predictor of patient outcomes than distensibility (DI). METHODS AND PROCEDURES A review of a prospectively maintained quality database was performed. Patients with FLIP measurements during laparoscopic fundoplication between August 2018 and June 2021 were included. GEJ compliance and DI were measured after hernia reduction, cruroplasty, and fundoplication. Patient-reported outcomes were collected through standardized surveys up to 2 years after surgery. A scatter plot was used to identify a correlation between compliance and DI. Comparisons of measurements between time points were made using paired t-tests. Spearman's correlation coefficients (ρ), Wilcoxon rank-sum, and chi-square tests were used to evaluate associations between measurements and outcomes. RESULTS One hundred and forty-four patients underwent laparoscopic fundoplication. Compliance is strongly associated with DI (r = 0.96), and a comparison of measurements showed similar trends at specific time points during the operation. After hernia reduction, compliance at the GEJ was 168 ± 74 mm3/mmHg, cruroplasty 79 ± 39 mm3/mmHg, and fundoplication 90 ± 33 mm3/mmHg (all comparisons p < 0.05). GEJ compliance of 80-92 mm3/mmHg after fundoplication was associated with the best patient-reported outcome scores. A compliance of ≤ 79 mm3/mmHg had the highest percentage of patients who reported dysphagia. CONCLUSIONS Compliance and DI are strongly associated displaying the same directional change during anti-reflux surgery. GEJ compliance of 80-92 mm3/mmHg revealed the best patient-reported outcome scores, and avoiding a compliance ≤ 79 mm3/mmHg may prevent postoperative dysphagia. Therefore, GEJ compliance is an underutilized FLIP measurement warranting further investigation.
Collapse
Affiliation(s)
- Hoover Wu
- Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA.
- Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA.
| | - Mikhail Attaar
- Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA
- Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA
| | - Harry J Wong
- Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA
- Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA
| | - Michelle Campbell
- Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA
- Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA
| | | | - Woody Denham
- Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA
| | - John Linn
- Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA
| | - Michael B Ujiki
- Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA
| |
Collapse
|
16
|
Wu H, Attaar M, Wong HJ, Campbell M, Kuchta K, Denham EW, Linn J, Ujiki MB. Impedance Planimetry (Endoflip) and Ideal Distensibility Ranges for Optimal Outcomes after Nissen and Toupet Fundoplication. J Am Coll Surg 2022; 235:420-429. [PMID: 35972160 DOI: 10.1097/xcs.0000000000000273] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Previous research has shown that impedance planimetry-based functional lumen imaging probe (FLIP) measurements are associated with patient-reported outcomes after laparoscopic antireflux surgery. We hypothesize that Nissen and Toupet fundoplications have different ideal FLIP profiles, such as distensibility. STUDY DESIGN A retrospective review of a prospectively maintained quality database was performed. Patients who had FLIP measurements during fundoplications between 2013 and 2021 were included. Reflux Symptom Index, Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire, and dysphagia score were collected for up to 2 years postoperatively. The Wilcoxon rank-sum test was used to compare FLIP measurements vs outcomes. RESULTS Two hundred fifty patients (171 Toupet, 79 Nissen) were analyzed. Distensibility ranges were categorized as tight, ideal, or loose. The ideal distensibility index range of Toupet patients with the 30- and 40-mL balloon fills were 2.6 to 3.7 mm2/mmHg. This range was associated with less dysphagia at 1 year compared with the tight group (p = 0.02). For Nissen patients, the 30- and 40-mL ideal threshold was a distensibility index of ≥2.2 mm2/mmHg. Patients with distensibility exceeding this threshold had a better quality of life than the tight group, reporting better Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire (p = 0.02) and lower dysphagia scores (p = 0.01) at 2 years. CONCLUSIONS Impedance planimetry revealed different ideal distensibility ranges after Toupet and Nissen fundoplications that are associated with improved patient-reported outcomes, suggesting that intraoperative FLIP has the potential to tailor fundoplication.
Collapse
Affiliation(s)
- Hoover Wu
- From the Department of Surgery, NorthShore University Health System, Evanston, IL (Wu, Attaar, Wong, Campbell, Denham, Linn, Ujiki).,Department of Surgery, University of Chicago Medical Center, Chicago, IL (Wu, Attaar, Wong, Campbell)
| | - Mikhail Attaar
- From the Department of Surgery, NorthShore University Health System, Evanston, IL (Wu, Attaar, Wong, Campbell, Denham, Linn, Ujiki).,Department of Surgery, University of Chicago Medical Center, Chicago, IL (Wu, Attaar, Wong, Campbell)
| | - Harry J Wong
- From the Department of Surgery, NorthShore University Health System, Evanston, IL (Wu, Attaar, Wong, Campbell, Denham, Linn, Ujiki).,Department of Surgery, University of Chicago Medical Center, Chicago, IL (Wu, Attaar, Wong, Campbell)
| | - Michelle Campbell
- From the Department of Surgery, NorthShore University Health System, Evanston, IL (Wu, Attaar, Wong, Campbell, Denham, Linn, Ujiki).,Department of Surgery, University of Chicago Medical Center, Chicago, IL (Wu, Attaar, Wong, Campbell)
| | - Kristine Kuchta
- cNorthShore University Research Institute, Evanston, IL (Kuchta)
| | - Ervin Woodford Denham
- From the Department of Surgery, NorthShore University Health System, Evanston, IL (Wu, Attaar, Wong, Campbell, Denham, Linn, Ujiki)
| | - John Linn
- From the Department of Surgery, NorthShore University Health System, Evanston, IL (Wu, Attaar, Wong, Campbell, Denham, Linn, Ujiki)
| | - Michael B Ujiki
- From the Department of Surgery, NorthShore University Health System, Evanston, IL (Wu, Attaar, Wong, Campbell, Denham, Linn, Ujiki)
| |
Collapse
|
17
|
Greenberg JA, Stefanova DI, Reyes FV, Edelmuth RCL, Thiesmeyer JW, Egan CE, Liu M, Schnoll-Sussman FH, Katz PO, Christos P, Finnerty BM, Fahey TJ, Zarnegar R. Quantifying physiologic parameters of the gastroesophageal junction during re-operative anti-reflux surgery. Surg Endosc 2022; 36:7008-7015. [PMID: 35102431 DOI: 10.1007/s00464-022-09025-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 01/03/2022] [Indexed: 12/11/2022]
Abstract
BACKGROUND Hiatal hernia re-approximation during index anti-reflux surgery (ARS) contributes approximately 80% of overall change in distensibility index (DI) and, potentially, compliance of the gastroesophageal (GEJ), while sphincter augmentation contributes approximately 20%. Whether this is seen in re-operative ARS is unclear. We quantify the physiologic parameters of the GEJ at each step of robotic re-operative ARS and compare these to index ARS. METHODS Robotic ARS with hiatal hernia repair was performed on 195 consecutive patients with pathologic reflux utilizing EndoFLIP™, of which 26 previously had ARS. Intra-operative GEJ measurements, including cross-sectional area (CSA), pressure, DI, and high-pressure zone (HPZ) length were collected pre-repair, post-diaphragmatic re-approximation, post-mesh placement, and post-lower-esophageal sphincter (LES) augmentation. RESULTS Both cohorts were similar by sex and BMI and underwent similar procedures. The re-operative cohort was older (60.6 ± 15.3 vs. 52.7 ± 16.2 years, p = 0.03), had more frequent pre-operative dysphagia (69.2% vs. 42.6%, p = 0.01) and esophageal dysmotility on barium swallow (75.0% vs. 35.0%, p < 0.001) but lower rates of hiatal hernia on endoscopy (30.8% vs. 68.7%, p < 0.001) compared to index procedures. Among the re-operative cohort, the CSA decreased by 34 (IQR - 80, - 15) mm2 and DI 1.1 (IQR - 2.4, - 0.6) mm2/mmHg (both p < 0.001). Pressure increased by 11.2 (IQR 4.7, 14.9) mmHg and HPZ by 1.5 (1,2) cm (both p < 0.001). These changes were similar to those seen in index ARS. Diaphragmatic re-approximation contributed to a greater percentage of overall change to the GEJ than did the augmentation procedure, with 72% of the change in DI occurring during hiatal closure, similar to that seen during index ARS. CONCLUSIONS During re-operative ARS, dynamic intra-operative monitoring can quantify the effects of each operative step on GEJ physiologic parameters. Diaphragmatic re-approximation appears to have a greater effect on GEJ physiology than does LES-sphincter augmentation during both index and re-operative ARS.
Collapse
Affiliation(s)
- Jacques A Greenberg
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Dessislava I Stefanova
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Fernando Valle Reyes
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Rodrigo C L Edelmuth
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Jessica W Thiesmeyer
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Caitlin E Egan
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Mengyuan Liu
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Felice H Schnoll-Sussman
- Department of Medicine, Division of Gastroenterology and Hepatology, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Philip O Katz
- Department of Medicine, Division of Gastroenterology and Hepatology, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Paul Christos
- Division of Biostatistics, Department of Population Health Sciences, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Brendan M Finnerty
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Thomas J Fahey
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Rasa Zarnegar
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA.
| |
Collapse
|
18
|
Callahan ZM, Amundson J, Su B, Kuchta K, Ujiki M. Outcomes after anti-reflux procedures: Nissen, Toupet, magnetic sphincter augmentation or anti-reflux mucosectomy? Surg Endosc 2022; 37:3944-3951. [PMID: 35999311 DOI: 10.1007/s00464-022-09544-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 08/07/2022] [Indexed: 10/15/2022]
Abstract
BACKGROUND Surgical treatment options of gastroesophageal reflux disease have changed significantly in the last 50 years. Magnetic Sphincter Augmentation (MSA) and Anti-reflux Mucosectomy (ARMs) are gaining traction but there is a paucity of literature comparing these novel options to Toupet fundoplication and gold standard Nissen fundoplication. METHODS This is a retrospective review of a prospectively maintained database, evaluating patients undergoing Nissen, Toupet, MSA, and ARMs. Pre-operative, intra-operative, and post-operative variables including Reflux symptom index (RSI), Gastroesophageal Reflux Disease-Health Related Quality of Life questionnaire (GERD-HRQL), and Dysphagia scores were compared between groups. RESULTS During the study period, 649 patients underwent anti-reflux surgery. Patients who underwent Nissen or Toupet were younger than those undergoing MSA or ARMs (65 ± 12 and 67 ± 14 years vs 56 ± 14 and 56 ± 18 years, P < 0.01). Average operative time for Nissen was 127 ± 40 min which was similar to a Toupet at 122 ± 32 min. These durations were significantly longer than for MSA, averaging 79 ± 29, and ARMs, at a mean 35 ± 3 min (all P < 0.001). Length of stay was significantly different among all four groups with Nissen, Toupet, MSA, and ARMs patients staying a median of 31, 24, 7, and 3 h post operatively, respectively (all P < 0.001). Complications and re-admissions were similarly low among all groups. Despite minor differences in RSI and GERD-HRQL scores at isolated follow-up time points, quality of life scores seems to be similar overall at up to 5 years follow-up. Gas bloat and dysphagia did not differ among groups at any time point. CONCLUSIONS Novel anti-reflux surgery options provide similar GERD-related quality of life compared to traditional full or partial fundoplications with the added benefit of shorter operative time and faster recovery.
Collapse
Affiliation(s)
- Zachary M Callahan
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL, USA.
| | - Julia Amundson
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL, USA
| | - Bailey Su
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL, USA
| | - Kristine Kuchta
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL, USA
| | - Michael Ujiki
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL, USA
| |
Collapse
|
19
|
Crural closure, not fundoplication, results in a significant decrease in lower esophageal sphincter distensibility. Surg Endosc 2022; 36:3893-3901. [PMID: 34463870 DOI: 10.1007/s00464-021-08706-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Accepted: 08/23/2021] [Indexed: 02/08/2023]
Abstract
INTRODUCTION The esophagogastric junction (EGJ) is a complex anti-reflux barrier whose integrity relies on both the intrinsic lower esophageal sphincter (LES) and extrinsic crural diaphragm. During hiatal hernia repair, it is unclear whether the crural closure or the fundoplication is more important to restore the anti-reflux barrier. The objective of this study is to analyze changes in LES minimum diameter (Dmin) and distensibility index (DI) using the endoluminal functional lumen imaging probe (FLIP) during hiatal hernia repair. METHODS Following implementation of a standardized operative FLIP protocol, all data were collected prospectively and entered into a quality database. This data were reviewed retrospectively for all patients undergoing hiatal hernia repair. FLIP measurements were collected prior to hernia dissection, after hernia reduction, after cruroplasty, and after fundoplication. Additionally, subjective assessment of the tightness of crural closure was rated by the primary surgeon on a scale of 1 to 5, 1 being the loosest and 5 being the tightest. RESULTS Between August 2018 and February 2020, 97 hiatal hernia repairs were performed by a single surgeon. FLIP measurements collected using a 40-mL volume fill without pneumoperitoneum demonstrated a significant decrease in LES Dmin (13.84 ± 2.59 to 10.27 ± 2.09) and DI (6.81 ± 3.03 to 2.85 ± 1.23 mm2/mmHg) after crural closure (both p < 0.0001). Following fundoplication, there was a small, but also statistically significant, increase in both Dmin and DI (both p < 0.0001). Additionally, subjective assessment of crural tightness after cruroplasty correlated well with DI (r = - 0.466, p < 0.001) and all patients with a crural tightness rating ≥ 4.5 (N = 13) had a DI < 2.0 mm2/mmHg. CONCLUSION Cruroplasty results in a significant decrease in LES distensibility and may be more important than fundoplication in restoring EGJ competency. Additionally, subjective estimation of crural tightness correlates well with objective FLIP evaluation, suggesting surgeon assessment of cruroplasty is reliable.
Collapse
|
20
|
Functional Luminal Imaging Probe in the Management of Pediatric Esophageal Disorders. J Pediatr Gastroenterol Nutr 2022; 74:516-522. [PMID: 34596605 DOI: 10.1097/mpg.0000000000003312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
BACKGROUND Functional luminal imaging probe (FLIP) measures pressure-geometry relationships of digestive luminal space. When used in esophageal disorders, it provides several luminal parameters that help better understand the pathophysiology. Data about the potential utility of FLIP in pediatrics are scarce and there is no standardized use in children. We aim to describe the use of FLIP in our center, its safety, feasibility, and clinical impact in esophageal disorders in children. METHODS Consecutive FLIP recordings performed at the Centre Hospitalier Universitaire-Sainte-Justine, Montréal, Canada between February 2018 and January 2021 were extracted. A chart review was conducted for demographics and medical history. Symptomatology after the procedure was evaluated with validated dysphagia scores. KEY RESULTS Nineteen patients were included (11 girls, median age 16 years, range 3.2-19.6) with achalasia (n = 5), post-Heller's myotomy dysphagia (n = 3), esophagogastric junction outflow obstruction (n = 3), congenital esophageal stenosis (n = 2); post-esophageal atresia repair stricture (n = 3), and post-fundoplication dysphagia (n = 3). There was no significant correlation between integrated relaxation pressure measured with high resolution manometry and distensibility index (DI). The use of FLIP made it possible to differentiate between dysphagia related to an esophageal obstruction (DI < 2.8 mm2/mmHg) and dysphagia without major motility disorder (DI > 2.8 mm2/mmHg) that guided the indication for dilation. FLIP led to a change in management in 47% of the patients. Forty-seven percent of the patients were symptom free at the time of the evaluation. CONCLUSIONS INFERENCES FLIP provides key esophageal luminal values and therefore can play an important role in pediatric esophageal disorders management.
Collapse
|
21
|
Wu H, Attaar M, Wong HJ, Campbell M, Kuchta K, Denham W, Linn J, Ujiki MB. Impedance planimetry (EndoFLIP™) after magnetic sphincter augmentation (LINX®) compared to fundoplication. Surg Endosc 2022; 36:7709-7716. [PMID: 35169878 DOI: 10.1007/s00464-022-09128-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 02/07/2022] [Indexed: 10/19/2022]
Abstract
INTRODUCTION Functional luminal imaging probe (FLIP) use during laparoscopic fundoplication (LF) for gastroesophageal reflux disease is well described. However, there is a lack of data on FLIP measurements during magnetic sphincter augmentation (MSA). This study aims to report our institutional experience in performing FLIP during MSA and to compare these measurements to those obtained during Nissen and Toupet fundoplication. METHODS AND PROCEDURES A retrospective review of a prospectively maintained quality database was performed. Patients who underwent MSA or LF and had FLIP measurements between April 2018 and June 2021 were included. FLIP measurements at the gastroesophageal junction (GEJ) were recorded without pneumoperitoneum at 40 mL balloon fill after hernia reduction, cruroplasty, and MSA or fundoplication. Reflux symptom index (RSI), GERD-HRQL, and dysphagia score were collected up to 2 years. Group comparisons were made using two-tailed Wilcoxon rank-sum and χ2 tests, with statistical significance of p < 0.05. RESULTS Twenty-seven patients underwent MSA and 100 patients underwent LF (66% Toupet, 34% Nissen). Type III hiatal hernia was present in 3.7% of MSA patients versus over 50% for fundoplication patients. Minimum diameter, cross-sectional area, and distensibility index (DI) were lower after MSA device placement compared to Nissen or Toupet fundoplication (p < 0.05). Postoperative follow-up showed no differences in RSI, GERD-HRQL, and dysphagia score between MSA and Nissen fundoplication (p > 0.05). CONCLUSION Intraoperative impedance planimetry provided objective information regarding the geometry of the GEJ during MSA. The ring of magnetic beads restores the anti-reflux barrier and transiently opens with food bolus and belching. The magnetic force of the beads may explain why the DI after MSA is lower yet postoperative quality of life is no different than Nissen fundoplication.
Collapse
Affiliation(s)
- Hoover Wu
- Department of Surgery, NorthShore University Health System, Evanston, IL, USA. .,Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA. .,Department of Surgery, NorthShore University Health System, 2650 Ridge Ave, GCSI Suite B665, Evanston, IL, 60201, USA.
| | - Mikhail Attaar
- Department of Surgery, NorthShore University Health System, Evanston, IL, USA.,Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA
| | - Harry J Wong
- Department of Surgery, NorthShore University Health System, Evanston, IL, USA.,Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA
| | - Michelle Campbell
- Department of Surgery, NorthShore University Health System, Evanston, IL, USA.,Department of Surgery, University of Chicago Medical Center, Chicago, IL, USA
| | | | - Woody Denham
- Department of Surgery, NorthShore University Health System, Evanston, IL, USA
| | - John Linn
- Department of Surgery, NorthShore University Health System, Evanston, IL, USA
| | - Michael B Ujiki
- Department of Surgery, NorthShore University Health System, Evanston, IL, USA
| |
Collapse
|
22
|
Greenberg JA, Stefanova DI, Reyes FV, Edelmuth RCL, Harik L, Thiesmeyer JW, Egan CE, Palacardo F, Liu M, Christos P, Schnoll-Sussman FH, Katz PO, Finnerty BM, Fahey TJ, Zarnegar R. Evaluation of post-operative dysphagia following anti-reflux surgery. Surg Endosc 2022; 36:5456-5466. [PMID: 34981222 DOI: 10.1007/s00464-021-08888-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 11/16/2021] [Indexed: 11/25/2022]
Abstract
BACKGROUND Anti-reflux surgery (ARS) has known long-term complications, including dysphagia, bloat, and flatulence, among others. The factors affecting the development of post-operative dysphagia are poorly understood. We investigated the correlation of intra-operative esophagogastric junction (EGJ) characteristics and procedure type with post-operative dysphagia following ARS. METHODS Robotic ARS was performed on 197 consecutive patients with pathologic reflux utilizing EndoFLIP™ technology. Intraoperative EGJ measurements including distensibility index (DI), cross-sectional area (CSA), and high-pressure zone (HPZ) length were collected. Dysphagia was assessed pre-operatively and at 3 months post-operatively. RESULTS The median pre-operative DI for all procedures was 2.6 (IQR 1.6-4.5) mm2/mmHg. There was no difference in post-operative DI between procedures [Hill: 0.9 (IQR 0.7-1.1) mm2/mmHg, Nissen: 1.0 (IQR 0.7-1.4) mm2/mmHg, Toupet: 1.2 (IQR 0.8-1.5) mm2/mmHg, Linx: 1.0 (IQR 0.7-1.2) mm2/mmHg, p = 0.24], whereas post-operative HPZ length differed by augmentation type [Hill: 3 (IQR 2.8-3) cm, Nissen: 3.5 (IQR 3-3.5) cm, Toupet: 3 (IQR 2.5-3.5) cm, Linx: 2.5 (IQR 2.5-3) cm, p = 0.032]. Eighty-nine patients (45.2%) had pre-operative dysphagia. Thirty-two patients (27.6%) reported any dysphagia at their 3-month post-operative visit and 12 (10.3%) developed new or worsening post-operative dysphagia [Hill: 2/18 (11.1%), Nissen: 2/35 (5.7%), Toupet: 4/54 (7.4%), Linx: 4/9 (44.4%), p = 0.006]. The median pre-operative and post-operative DI of patients who developed new or worsening dysphagia was 2.0 (IQR 0.9-3.8) mm2/mmHg and 1.2 (IQR 1.0-1.8) mm2/mmHg, respectively, and that of those who did not was 2.5 (IQR 1.6-4.0) mm2/mmHg and 1.0 (IQR 0.7-1.4) mm2/mmHg (p = 0.21 and 0.16, respectively). CONCLUSIONS Post-operative DI was similar between procedures, and there was no correlation with new or worsening post-operative dysphagia. Linx placement was associated with higher rates of new or worsening post-operative dysphagia despite a shorter post-procedure HPZ length and similar post-operative DI when compared to other methods of LES augmentation.
Collapse
Affiliation(s)
- Jacques A Greenberg
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Dessislava I Stefanova
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Fernando Valle Reyes
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Rodrigo C L Edelmuth
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Lamia Harik
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Jessica W Thiesmeyer
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Caitlin E Egan
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Federico Palacardo
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Mengyuan Liu
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Paul Christos
- Division of Biostatistics, Department of Population Health Sciences, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Felice H Schnoll-Sussman
- Division of Gastroenterology and Hepatology, Department of Medicine, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Philip O Katz
- Division of Gastroenterology and Hepatology, Department of Medicine, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA
| | - Brendan M Finnerty
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Thomas J Fahey
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Rasa Zarnegar
- Department of Surgery, Division of Endocrine & Minimally Invasive Surgery, Weill Cornell Medical College, New York-Presbyterian Hospital, 525 East 68th Street, K-836, New York, NY, 10065, USA.
| |
Collapse
|
23
|
Impedance Planimetry (Endoflip™) Shows That Length of Narrowing After Fundoplication Does Not Impact Dysphagia. J Gastrointest Surg 2022; 26:21-29. [PMID: 34647227 DOI: 10.1007/s11605-021-05153-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 08/21/2021] [Indexed: 01/31/2023]
Abstract
INTRODUCTION A short floppy fundoplication has been the surgical dogma to prevent dysphagia and gas-bloat after laparoscopic fundoplication while adequately addressing gastroesophageal reflux disease. The literature on the ideal length of narrowing (LON) of the gastroesophageal junction after fundoplication is sparse. The functional luminal imaging probe (FLIP) can be used during anti-reflux surgery to produce a visual representation of the LON. We hypothesize that a longer LON provides relief of GERD symptoms, however worse dysphagia and gas-bloat. METHODS AND PROCEDURES Prospectively collected data was analyzed. Patients with FLIP measurements during laparoscopic fundoplication between August 2018 and December 2020 were included. FLIP measurements at the gastroesophageal junction were recorded without pneumoperitoneum at 40-mL balloon fill after fundoplication. Reflux Symptom Index (RSI), Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire (GERD-HRQL), gas-bloat score, and Dysphagia Score were collected. Comparisons were made using Spearman correlation coefficients (r) and two-tailed Wilcoxon rank-sum tests, with statistical significance set at p < 0.05. RESULTS One hundred and eleven patients underwent laparoscopic fundoplication (26% Nissen, 74% Toupet) and had FLIP measurements. Mean LON in this cohort was 2.7 ± 0.8 cm and mean DI was 3.5 ± 1.3 mm2/mmHg. LON is inversely associated with RSI (r = - 0.29, p = 0.04) and gas-bloat (r = - 0.30, p = 0.04). There was no association with Dysphagia Score. Patients with a LON of 2.5-4.5 cm and DI of 2.5-3.6 mm2/mmHg after fundoplication reported lower RSI (p = 0.03) and GERD-HRQL (p = 0.04) compared to patients outside of these ranges. There were no significant differences in patient-reported dysphagia or gas-bloat scores at 1 year between these groups. CONCLUSIONS Impedance planimetry provides objective real-time measurements and images during anti-reflux surgery, which allows surgeons to measure the length of narrowing after fundoplication. A LON of 2.5-4.5 cm and DI of 2.5-3.6 mm2/mmHg after fundoplication led to better postoperative quality of life at 1 year without an increase in postoperative dysphagia or gas-bloat.
Collapse
|
24
|
Song EJ, Yadlapati R, Chen JW, Parish A, Whitson MJ, Ravi K, Patel A, Carlson DA, Khan A, Niedzwiecki D, Leiman DA. Variability in endoscopic assessment of Nissen fundoplication wrap integrity and hiatus herniation. Dis Esophagus 2021; 35:6486651. [PMID: 34963133 PMCID: PMC9118466 DOI: 10.1093/dote/doab078] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Accepted: 11/07/2021] [Indexed: 12/11/2022]
Abstract
BACKGROUND Upper endoscopy (EGD) is frequently performed in patients with esophageal complaints following anti-reflux surgery such as fundoplication. Endoscopic evaluation of fundoplication wrap integrity can be challenging. Our primary aim in this pilot study was to evaluate the accuracy and confidence of assessing Nissen fundoplication integrity and hiatus herniation among gastroenterology (GI) fellows, subspecialists, and foregut surgeons. METHODS Five variations of post-Nissen fundoplication anatomy were included in a survey of 20 sets of EGD images that was completed by GI fellows, general GI attendings, esophagologists, and foregut surgeons. Accuracy, diagnostic confidence, and inter-rater agreement across providers were evaluated. RESULTS There were 31 respondents in the final cohort. Confidence in pre-survey diagnostics significantly differed by provider type (mean confidence out of 5 was 1.8 for GI fellows, 2.7 for general GI attendings, 3.6 for esophagologists, and 3.6 for foregut surgeons, P = 0.01). The mean overall accuracy was 45.9%, which significantly differed by provider type with the lowest rate among GI fellows (37%) and highest among esophagologists (53%; P = 0.01). The accuracy was highest among esophagologists across all wrap integrity variations. Inter-rater agreement was low across wrap integrity variations (Krippendorf's alpha <0.30), indicating low to no agreement between providers. CONCLUSION In this multi-center survey study, GI fellows had the lowest accuracy and confidence in assessing EGD images after Nissen fundoplication, whereas esophagologists had the highest. Diagnostic confidence varied considerably and inter-rater agreement was poor. These findings suggest experience may improve confidence, but highlight the need to improve the evaluation of fundoplication wraps.
Collapse
Affiliation(s)
- Erin J Song
- Department of Medicine, Duke University, Durham, NC, USA
| | - Rena Yadlapati
- Division of Gastroenterology, University of California San Diego, La Jolla, CA, USA
| | - Joan W Chen
- Division of Gastroenterology, University of Michigan, Ann Arbor, MI, USA
| | - Alice Parish
- Department of Biostatistics and Bioinformatics, Duke University, Durham, NC, USA
| | - Matthew J Whitson
- Division of Gastroenterology, Zucker School of Medicine at Hofstra-Northwell, Manhasset, NY, USA
| | - Karthik Ravi
- Division of Gastroenterology, Mayo Clinic, Rochester, MN, USA
| | - Amit Patel
- Division of Gastroenterology, Duke University, Durham, NC, USA
| | - Dustin A Carlson
- Division of Gastroenterology, Northwestern University, Chicago, IL, USA
| | - Abraham Khan
- Division of Gastroenterology, New York University-Langone Health, New York, NY, USA
| | - Donna Niedzwiecki
- Department of Biostatistics and Bioinformatics, Duke University, Durham, NC, USA
| | - David A Leiman
- Address correspondence to: David A. Leiman. University School of Medicine, 200 Morris Street, Suite 6524, Durham, NC 27701, USA.
| |
Collapse
|
25
|
Wu H, Attaar M, Wong HJ, Campbell M, Kuchta K, Ungerleider S, Denham W, Linn J, Ujiki MB. Impedance planimetry (EndoFLIP) measurements persist long term after anti-reflux surgery. Surgery 2021; 171:628-634. [PMID: 34865861 DOI: 10.1016/j.surg.2021.08.065] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 08/18/2021] [Accepted: 08/19/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE The functional lumen imaging probe provides objective measurements of the gastroesophageal junction during laparoscopic anti-reflux surgery. There is a lack of data on how functional lumen imaging probe measurements change at follow-up. We aim to describe our institutional experience in performing functional lumen imaging probe during postoperative endoscopy after laparoscopic anti-reflux surgery. METHODS A prospectively maintained database was queried. Patients who had postoperative endoscopic functional lumen imaging probe measurements between March 2018 and June 2021 were assessed at different time points from their index laparoscopic anti-reflux surgery using paired t test. Standardized quality of life questionnaires were collected for up to 2 years. Group comparisons were made using the Wilcoxon rank-sum test. RESULTS Fifty-eight patients who underwent laparoscopic anti-reflux surgery (magnetic sphincter augmentation or fundoplication) had postoperative functional lumen imaging probe. Thirty-two intraoperative functional lumen imaging probe values were compared with their postoperative functional lumen imaging probe. Fundoplication values did not differ. Postoperative functional lumen imaging probe distensibility index for magnetic sphincter augmentation patients was decreased (P = .04). Functional lumen imaging probe measurements for all postoperative endoscopies showed that magnetic sphincter augmentation had the lowest distensibility index (P < .01). Dysphagia as a reason for endoscopy had a decrease in distensibility index (P = .03). CONCLUSION Functional lumen imaging probe measurements after fundoplication persist at long-term follow up while patients may have a tighter gastroesophageal junction after magnetic sphincter augmentation. Functional lumen imaging probe has the potential to assess the success or failure after laparoscopic anti-reflux surgery and optimize patient outcomes.
Collapse
Affiliation(s)
- Hoover Wu
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL.
| | - Mikhail Attaar
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL
| | - Harry J Wong
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL
| | - Michelle Campbell
- Department of Surgery, NorthShore University Health System, Evanston, IL; Department of Surgery, University of Chicago Medical Center, Chicago, IL
| | | | | | - Woody Denham
- Department of Surgery, NorthShore University Health System, Evanston, IL
| | - John Linn
- Department of Surgery, NorthShore University Health System, Evanston, IL
| | - Michael B Ujiki
- Department of Surgery, NorthShore University Health System, Evanston, IL
| |
Collapse
|
26
|
Linnaus ME, Garren A, Gould JC. Anatomic location and mechanism of hiatal hernia recurrence: a video-based assessment. Surg Endosc 2021; 36:5451-5455. [PMID: 34845542 DOI: 10.1007/s00464-021-08887-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Accepted: 11/16/2021] [Indexed: 01/13/2023]
Abstract
INTRODUCTION Hiatal hernia recurrence following surgical repair is common. We sought to define the most common anatomic location and mechanism for hiatal failure to inform technical strategies to decrease recurrence rates. METHODS Retrospective chart review and video analysis were performed for all recurrent hiatal hernia operations performed by a single surgeon between January 2013 and April 2020. Hiatal recurrences were defined by anatomic quadrants. Recurrences on both left and right on either the anterior or posterior portion of the hiatus were simply classified as 'anterior' or 'posterior', respectively. Three or more quadrants were defined as circumferential. Mechanism of recurrence was defined as disruption of the previous repair or dilation of the hiatus. RESULTS There were 130 patients to meet criteria. Median time to reoperation from previous hiatal repair was 60 months (IQR19.5-132). First-time recurrent repairs accounted for 74%, second time 18%, and three or more previous repairs for 8% of analyzed procedures. Mesh had been placed at the hiatus in a previous operation in 16%. All reoperative cases were completed laparoscopically. Video analysis revealed anterior recurrences were most common (67%), followed by circumferential (29%). There were two with left-anterior recurrence (1.5%), two posterior recurrence (1.5%), and one right-sided recurrence. The mechanism of recurrence was dilation in 74% and disruption in 26%. Disruption as a mechanism was most common in circumferential hiatal failures. Neither the prior number of hiatal surgeries nor the presence of mesh at the time of reoperation correlated with anatomic recurrence location or mechanism. Reoperations in patients with hiatal disruption occurred after a shorter interval when compared to hiatal dilation. CONCLUSION The most common location and mechanism for hiatal hernia recurrence is anterior dilation of the hiatus. Outcomes following techniques designed to reinforce the anterior hiatus and perhaps to prevent hiatal dilation should be explored.
Collapse
Affiliation(s)
- Maria E Linnaus
- Department of Surgery, Division of Minimally Invasive and Gastrointestinal Surgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA
| | - Anna Garren
- Department of Surgery, Division of Minimally Invasive and Gastrointestinal Surgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA
| | - Jon C Gould
- Department of Surgery, Division of Minimally Invasive and Gastrointestinal Surgery, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA.
| |
Collapse
|
27
|
Yano F, Tsuboi K, Omura N, Hoshino M, Yamamoto SR, Akimoto S, Masuda T, Mitsumori N, Ikegami T. Treatment strategy for laparoscopic hiatal hernia repair. Asian J Endosc Surg 2021; 14:684-691. [PMID: 33472278 DOI: 10.1111/ases.12918] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 01/06/2021] [Indexed: 12/13/2022]
Abstract
INTRODUCTION According to the anatomy-function-pathology classification, the recurrence rates of A2 and A3 hiatal hernia (HH) after laparoscopic fundoplication are higher than the rate of A1 HH. Therefore, we introduced mesh reinforcement for A2 and A3 cases. In addition, gastropexy was added to A3 cases. We present the strategy for HH repair. METHODS In all, 537 patients (mean age 55.4 ± 16.7 years, 219 women) who underwent primary laparoscopic fundoplication for HH from January 1995 to October 2019 were included. They were divided into three groups by A factor (A1:A2:A3 = 296:156:85). Their clinical data were collected in a prospective fashion and retrospectively reviewed. RESULTS The median age (years) of the patients in each group was A1:A2:A3 = 46:63:74 years, and age was directly proportional to the size of HH (P < 0.0001). The proportion of females was significantly higher in A3 than in other classes (P < 0.0001). Preoperative reflux esophagitis was severe in A2 (P < 0.0001) and operation time (min) was directly proportional to HH size (A1:A2:A3 = 135:167:193, P < 0.0001). The recurrence rate of conventional laparoscopic fundoplication was 15% (46/304), and it was higher for A2 and A3 than for A1 (P = 0.027). However, with reinforcement of the hiatus using a mesh and gastropexy, the recurrence rates decreased. CONCLUSION Combining mesh reinforcement and gastropexy may reduce the recurrence rate of para- and mixed-type HH.
Collapse
Affiliation(s)
- Fumiaki Yano
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Kazuto Tsuboi
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Nobuo Omura
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Masato Hoshino
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Se R Yamamoto
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Shunsuke Akimoto
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Takahiro Masuda
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Norio Mitsumori
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Toru Ikegami
- Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| |
Collapse
|
28
|
Wong HJ, Su B, Attaar M, Kuchta K, Linn JG, Haggerty SP, Denham W, Ujiki MB. Teaching EndoFLIP Impedance Planimetry to Practicing Endoscopists: An "Into the Fire" Approach to Simulation. Surg Innov 2021; 29:241-248. [PMID: 34403287 DOI: 10.1177/15533506211038088] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Background. There are growing interests from practicing endoscopists to implement the functional lumen imaging probe (FLIP) impedance planimetry system. We present a simulation-based curriculum using an "into the fire" approach with hands-on pre- and post-tests to teach the use of this technology. Methods. The curriculum consists of a series of pre-tests, didactic content, mentored hands-on instructions, and post-tests. Pre- and post-testing included a knowledge-based written test, a confidence survey, and an assessment form specific to the hands-on performance of FLIP. Result. Twenty-two practicing physicians completed the curriculum. After course completion, participants had improved knowledge-based written test scores from 6.8±1.7 to 8.9±0.9 (P<0.001), confidence scores from 10.0±5.9 to 22.1±2.6 (P<0.001), and hands-on performance score from 11.4±3.4 to 23.1±2.0 (P<0.001) with significant improvement in all components of the hands-on skills. Conclusion. Our simulation curriculum is effective in improving confidence, knowledge, and technical proficiency when teaching the use of FLIP to practicing physicians.
Collapse
Affiliation(s)
- Harry J Wong
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA.,Department of Surgery, 21727University of Chicago Medicine, Chicago, IL, USA
| | - Bailey Su
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA.,Department of Surgery, 21727University of Chicago Medicine, Chicago, IL, USA
| | - Mikhail Attaar
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA.,Department of Surgery, 21727University of Chicago Medicine, Chicago, IL, USA
| | - Kristine Kuchta
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA
| | - John G Linn
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA
| | - Stephen P Haggerty
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA
| | - Woody Denham
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA
| | - Michael B Ujiki
- Department of Surgery, 3271NorthShore University HealthSystem, Evanston, IL, USA
| |
Collapse
|
29
|
Xiao YL, Zhou LY, Hou XH, Li YQ, Zou DW, Chen MH. Chinese expert consensus on gastroesophageal reflux disease in 2020. J Dig Dis 2021; 22:376-389. [PMID: 34105263 DOI: 10.1111/1751-2980.13028] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 06/07/2021] [Indexed: 12/11/2022]
Affiliation(s)
- Ying Lian Xiao
- Department of Gastroenterology, First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| | - Li Ya Zhou
- Department of Gastroenterology, Peking University Third Hospital, Beijing, China
| | - Xiao Hua Hou
- Department of Gastroenterology, Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Yan Qing Li
- Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, Shandong Province, China
| | - Duo Wu Zou
- Department of Gastroenterology, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Min Hu Chen
- Department of Gastroenterology, First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| | | |
Collapse
|
30
|
Liu M, Stefanova DI, Finnerty BM, Schnoll-Sussman FH, Katz PO, Fahey TJ, Zarnegar R. The impact of pneumoperitoneum on esophagogastric junction distensibility during anti-reflux surgery. Surg Endosc 2021; 36:367-374. [PMID: 33492498 DOI: 10.1007/s00464-021-08291-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 01/05/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE We aimed to quantify the contribution of pneumoperitoneum on compliance of the esophagogastric junction (EGJ) during anti-reflux surgery. BACKGROUND Compliance of the EGJ is reduced with anti-reflux surgery. EndoFLIP® planimetry can be used to assess dynamic changes of EGJ compliance intraoperatively. It is unclear how pneumoperitoneum impacts intraoperative measurements by EndoFLIP® and the implications thereof on validity of the results. Therefore, determining variability in EndoFLIP® measurements based on pneumoperitoneum is warranted to establish guidelines to interpret clinical outcomes. METHODS Primary anti-reflux surgery was performed on 39 consecutive patients with pathologic reflux. Intraoperative EGJ measurements including distensibility index (DI), cross-sectional area (CSA), and intrabag pressure were collected using EndoFLIP® at 0, 10, and 15 mmHg of intraperitoneal pressure. Data were acquired pre-procedure, post-hiatal hernia repair, and post-LES augmentation with fundoplications. RESULTS Patients underwent Nissen (13.2%), Toupet (68.4%), LINX (10.5%), or Hill-fundoplications (7.9%). There was no difference between 0 and 10 mmHg of pneumoperitoneum in CSA, pressure, or DI measurements pre-procedure; however, there was a difference between 0 and 15 mmHg in pressure (p = 0.016) and DI (p = 0.023) measurements. After LES augmentation, 10 mmHg intraperitoneal pressure reduced DI, though the absolute difference is small (2.0 vs. 1.5 mm2/mmHg, p = 0.002). CONCLUSION Pneumoperitoneum affected EGJ distensibility at 15 mmHg, but not 10 mmHg, of insufflation prior to anti-reflux procedures. After anti-reflux surgery, there was a significant variance between 0 and 10 mmHg of pneumoperitoneum in pressure and distensibility. The change in pressure appears linear and needs to be considered if procedural modifications are performed based on intraoperative findings and when evaluating clinical outcomes.
Collapse
Affiliation(s)
- Mengyuan Liu
- Division of Endocrine and Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Dessislava I Stefanova
- Division of Endocrine and Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Brendan M Finnerty
- Division of Endocrine and Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Felice H Schnoll-Sussman
- Division of Gastroenterology and Hepatology, Department of Medicine, New York-Presbyterian Hospital, Weill Cornell Medical College, New York, NY, USA
| | - Philip O Katz
- Division of Gastroenterology and Hepatology, Department of Medicine, New York-Presbyterian Hospital, Weill Cornell Medical College, New York, NY, USA
| | - Thomas J Fahey
- Division of Endocrine and Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68th Street, K-836, New York, NY, 10065, USA
| | - Rasa Zarnegar
- Division of Endocrine and Minimally Invasive Surgery, Department of Surgery, New York-Presbyterian Hospital, Weill Cornell Medical College, 525 East 68th Street, K-836, New York, NY, 10065, USA.
| |
Collapse
|
31
|
Savarino E, di Pietro M, Bredenoord AJ, Carlson DA, Clarke JO, Khan A, Vela MF, Yadlapati R, Pohl D, Pandolfino JE, Roman S, Gyawali CP. Use of the Functional Lumen Imaging Probe in Clinical Esophagology. Am J Gastroenterol 2020; 115:1786-1796. [PMID: 33156096 PMCID: PMC9380028 DOI: 10.14309/ajg.0000000000000773] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The functional lumen imaging probe (FLIP) measures luminal dimensions using impedance planimetry, performed most often during sedated upper endoscopy. Mechanical properties of the esophageal wall and opening dynamics of the esophagogastric junction (EGJ) can be objectively evaluated in esophageal motor disorders, eosinophilic esophagitis, esophageal strictures, during esophageal surgery and in postsurgical symptomatic states. Distensibility index, the ratio of EGJ cross sectional area to intraballoon pressure, is the most useful FLIP metric. Secondary peristalsis from balloon distension can be displayed topographically as repetitive anterograde or retrograde contractile activity in the esophageal body, similar to high-resolution manometry. Real-time interpretation and postprocessing of FLIP metadata can complement the identification of esophageal outflow obstruction and achalasia, especially when findings are inconclusive from alternate esophageal tests in symptomatic patients. FLIP can complement the diagnosis of achalasia when manometry and barium studies are inconclusive or negative in patients with typical symptoms. FLIP can direct adequacy of disruption of the EGJ in achalasia when used during and immediately after myotomy and pneumatic dilation. Lumen diameter measured using FLIP in eosinophilic esophagitis and in complex strictures can potentially guide management. An abbreviated modification of the Grading of Recommendations Assessment, Development, and Evaluation was used to determine the quality of available evidence and recommendations regarding FLIP utilization. FLIP metrics that are diagnostic or suggestive of an abnormal motor pattern and metrics that define normal esophageal physiology were developed by consensus and are described in this review.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Rena Yadlapati
- University of California in San Diego, La Jolla, California, USA
| | | | | | | | | |
Collapse
|
32
|
Using a standardized intra-operative endoflip protocol during fundoplication to identify factors that affect distensibility. Surg Endosc 2020; 35:5717-5723. [PMID: 32970210 DOI: 10.1007/s00464-020-08034-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 09/16/2020] [Indexed: 01/08/2023]
Abstract
INTRODUCTION The Endoluminal Functional Lumen Imaging Probe (Endoflip) can be used to provide objective measurements of the gastroesophageal junction during fundoplication, and recent publications have suggested that this device could improve surgical outcomes. However, the impact of operative variables has not been clearly reported. The aim of this study is to determine the effect of these variables on functional lumen imaging probe (FLIP) measurements. METHODS Following implementation of a standardized operative FLIP protocol, all data were collected prospectively and entered into a quality database. This database was queried for patients undergoing hiatal hernia repair and fundoplication. The protocol utilized various balloon volumes (30 and 40 ml), patient positions (flat and reverse Trendelenburg) and amounts of insufflation (15 mmHg pneumoperitoneum and no pneumoperitoneum). RESULTS Between August 2018 and February 2020, 97 fundoplications were performed by a single surgeon. Multivariable analysis without interactions demonstrated that a 40 ml volume fill resulted in significantly higher minimum diameter (Dmin), cross-sectional area (CSA), intra-balloon pressure (IBP) and distensibility index (DI) compared to a 30 ml volume fill (p < 0.001). While reverse Trendelenburg positioning resulted in a significantly higher Dmin, IBP and CSA compared to the flat position (all p < 0.05), there was little impact of positioning on DI. Lastly, pneumoperitoneum significantly increased IBP (p < 0.001) but did not affect Dmin (p = 0.697) or CSA (p = 0.757), which resulted in a significant decrease in DI (p < 0.001) when compared to measurements without pneumoperitoneum. Multivariable analysis allowing for interactions demonstrated significant two-way interactions between balloon volume and pneumoperitoneum (p = 0.047), as well as patient position and pneumoperitoneum (p < 0.001). CONCLUSION Surgeons should consider balloon volume and the presence or absence of pneumoperitoneum when interpreting distensibility during or after fundoplication. Additionally, we suggest a formal standardized protocol for FLIP measurements to utilize a 40 ml volume fill in reverse Trendelenburg without pneumoperitoneum.
Collapse
|
33
|
Su B, Wong HJ, Attaar M, Kuchta K, Linn JG, Haggerty SP, Denham W, Ujiki MB. Comparing short-term patient outcomes after fundoplication performed over a traditional bougie versus a functional lumen imaging probe. Surgery 2020; 169:533-538. [PMID: 32919782 DOI: 10.1016/j.surg.2020.07.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 06/30/2020] [Accepted: 07/14/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND The functional lumen imaging probe is a balloon-based catheter that can be used as a bougie during fundoplication. Our goal was to compare the short-term, quality-of-life outcomes and esophageal-injury rate after fundoplication over a functional lumen imaging probe compared to a traditional bougie. METHODS This is a retrospective review of a quality database at a single center. Three-week and 6-month Reflux Symptom Index, Gastroesophageal Reflux Disease-health Related Quality of Life, and dysphagia scores were compared. The need for endoscopy and dilation between the groups was also compared. RESULTS Between 2008 and 2020, 423 fundoplications were performed over a bougie and 62 over the functional lumen imaging probe. Six months after surgery, the functional lumen imaging probe group reported significantly worse dysphagia scores (1.5 ± 1.0 vs 1.1 ± 0.3, P = .007), but rates of endoscopy (4.8% vs 5.0%, P = .966) and dilation (4.8% vs 3.8%, P = .723) were similar. There were no differences between Reflux Symptom Index and Gastroesophageal Reflux Disease-health Related Quality of Life scores. The rate of bougie-related injuries was 2.1% vs 0% for the functional lumen imaging probe group. CONCLUSION Patients undergoing fundoplication over the functional lumen imaging probe had comparable short-term outcomes compared with those over a traditional bougie. The rate of esophageal injury while using the functional lumen imaging probe is lower than a bougie and may be preferable for fundoplication creation.
Collapse
Affiliation(s)
- Bailey Su
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL; Department of Surgery, University of Chicago, IL.
| | - Harry J Wong
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL; Department of Surgery, University of Chicago, IL
| | - Mikhail Attaar
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL; Department of Surgery, University of Chicago, IL
| | - Kristine Kuchta
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL
| | - John G Linn
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL
| | | | - Woody Denham
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL
| | - Michael B Ujiki
- Department of Surgery, NorthShore University HealthSystem, Evanston, IL
| |
Collapse
|
34
|
Dorsey YC, Posner S, Patel A. Esophageal Functional Lumen Imaging Probe (FLIP): How Can FLIP Enhance Your Clinical Practice? Dig Dis Sci 2020; 65:2473-2482. [PMID: 32671586 DOI: 10.1007/s10620-020-06443-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 06/21/2020] [Indexed: 12/11/2022]
Abstract
Recent innovations in esophageal diagnostic testing have enhanced gastroenterology clinical practice by facilitating more nuanced and advanced evaluation of esophageal symptoms. Among these pivotal advances is the FDA-approved functional lumen imaging probe (FLIP), which utilizes impedance planimetry via volumetric distension of a catheter-mounted balloon at the time of sedated upper endoscopy, to acquire esophageal dimensions and pressures. In real time, FLIP can display cross-sectional areas (CSA) and distensibility indices (ratios of CSA to intra-balloon pressures) throughout the esophagus, most notably at the esophagogastric junction, as well as secondary peristaltic esophageal body contractile patterns. As the use of FLIP has progressively spread and permeated into the practice of clinical gastroenterology since its introduction, increasing data on and experiences with its applications have accumulated to guide its utility in clinical practice. In this current review developed for gastroenterologists and foregut surgeons across clinical practice, we provide an introduction to FLIP technology and metrics and discuss the clinical scenarios in which performance of or referral for FLIP may be helpful in the evaluation and management of patients with commonly encountered esophageal symptoms and disorders. Specifically, we discuss the potential applications and limitations of FLIP as a complementary diagnostic modality in patients with non-obstructive dysphagia, established or suspected achalasia spectrum disorders, eosinophilic esophagitis, gastroesophageal reflux disease and those undergoing esophageal surgery.
Collapse
Affiliation(s)
- Y Claire Dorsey
- Division of Gastroenterology, Duke University School of Medicine, DUMC Box 3913, Durham, NC, 27710, USA.,Division of Gastroenterology, Durham Veterans Affairs Medical Center, Durham, NC, USA
| | - Shai Posner
- Division of Gastroenterology, Duke University School of Medicine, DUMC Box 3913, Durham, NC, 27710, USA.,Division of Gastroenterology, Durham Veterans Affairs Medical Center, Durham, NC, USA
| | - Amit Patel
- Division of Gastroenterology, Duke University School of Medicine, DUMC Box 3913, Durham, NC, 27710, USA. .,Division of Gastroenterology, Durham Veterans Affairs Medical Center, Durham, NC, USA.
| |
Collapse
|
35
|
Desprez C, Roman S, Leroi AM, Gourcerol G. The use of impedance planimetry (Endoscopic Functional Lumen Imaging Probe, EndoFLIP ® ) in the gastrointestinal tract: A systematic review. Neurogastroenterol Motil 2020; 32:e13980. [PMID: 32856765 DOI: 10.1111/nmo.13980] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 08/03/2020] [Accepted: 08/05/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND PURPOSE The EndoFLIP® system is a method of delineating impedance and was first designed to investigate the characteristics of the esophago-gastric junction. In the last decade, its use was widened to investigate other sphincteric and non-sphincteric systems of the gastrointestinal tract. The objective of the present systematic review was to summarize the available data in literature on the use of the EndoFLIP® system in the gastrointestinal tract, including sphincteric and non-sphincteric regions. We performed a systematic review in accordance with recommendations for systematic review using PRISMA guidelines without date restriction, until June 2020, using MEDLINE-PubMed, Cochrane Library, and Google Scholar databases. Only articles written in English were included in the present review. Five hundred and six unique citations were identified from all database combined. Of those, 95 met the inclusion criteria. There was a lack of standardization among studies in terms of anesthetic drugs use, probe placement, and inflation protocol. In most cases, only small cohorts of patients were included. Most studies investigated the EGJ, with a potential use of the EndoFLIP® to identify a subgroup of patients with achalasia and for intraoperative assessment of treatment efficacy in achalasia. However, the use of EndoFLIP® in the esophageal body (esophageal panometry), other esophageal diseases (gastro-esophageal reflux disease, eosinophilic esophagitis), and other sphincter regions (anal canal, pylorus) will need further confirmatory studies. The EndoFLIP® system provides detailed geometric data of the gastrointestinal lumen but further works are needed to determine its use in clinical practice.
Collapse
Affiliation(s)
- Charlotte Desprez
- Digestive Physiology Department, Rouen University Hospital, Rouen, France
- Nutrition, Brain and Gut Laboratory, INSERM unit 1073, Rouen University Hospital, Rouen, France
| | - Sabine Roman
- Digestive Physiology Department, Hospices Civils de Lyon, Hopital H Herriot, Lyon, France
| | - Anne Marie Leroi
- Digestive Physiology Department, Rouen University Hospital, Rouen, France
- Nutrition, Brain and Gut Laboratory, INSERM unit 1073, Rouen University Hospital, Rouen, France
- Clinical Investigation Center, CIC-CRB 1404, Rouen University Hospital, Rouen, France
| | - Guillaume Gourcerol
- Digestive Physiology Department, Rouen University Hospital, Rouen, France
- Nutrition, Brain and Gut Laboratory, INSERM unit 1073, Rouen University Hospital, Rouen, France
- Clinical Investigation Center, CIC-CRB 1404, Rouen University Hospital, Rouen, France
| |
Collapse
|
36
|
Nwokedi U, Nguyen DT, Meisenbach LM, Chihara R, Chan EY, Graviss EA, Kim MP. Short-term outcome of routine use of EndoFLIP during hiatal hernia repair. Surg Endosc 2020; 35:3840-3849. [PMID: 32661713 DOI: 10.1007/s00464-020-07788-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 07/02/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Endoluminal functional lumen imaging probe (EndoFLIP) technology is a tool that can be used to provide intraoperative objective real-time feedback during hiatal hernia repair. We wanted to determine the implication of initial distensibility index (DI) after mobilization of hiatus and final DI after creation of barrier in short-term clinical outcomes. METHODS We performed a retrospective analysis of prospectively collected data on the intraoperative use of EndoFLIP during hiatal hernia repair at a single institution from 2017 to 2019. We analyzed the initial DI and final DI with the short-term clinical outcomes. RESULTS There were 163 patients who had Nissen (n = 16), Toupet (n = 79) or magnetic sphincter augmentation (n = 68) with (n = 158) or without (n = 5) hiatal hernia repair with median initial DI was 3.2 mm2/mmHg. We used 3 mm2/mmHg as the cutoff for low (n = 84) vs. high (n = 79) initial DI group. There was no difference in DeMeester score (p = 0.76), the peristalsis on manometry (p = 0.13), type of hiatal hernia (p = 0.98), and GERD-HRQL score prior to surgery (p = 0.73) between the groups. There was significantly higher final DI in the high initial DI group compared to low initial DI group; however, there was no significant difference in the GERD-HRQL score at 1-3 months (p = 0.28). All of the patients had a final DI > 0.5 mm2/mmHg at the end of the case with median final DI of 1.6 mm2/mmHg. None of these patients required steroids (0%) and only one patient (0.6%) required EGD and dilatation as well as re-operation for dysphagia within 3 months. CONCLUSIONS The initial DI was associated with final DI, but it did not correlate with improvement in short-term GERD-HRQL score. Final DI maintained above the cutoff value led to most of the patients not to require intervention for dysphagia. Use of the EndoFLIP can provide objective data during the operation and prevent severe dysphagia after repair.
Collapse
Affiliation(s)
- Ugoeze Nwokedi
- Division of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA
- Department of Surgery and Cardiothoracic Surgery, Weill Cornell Medical College, Houston Methodist Hospital, Houston, TX, USA
| | - Duc T Nguyen
- Department of Pathology and Genomic Medicine, Houston Methodist Research Institute, Houston, TX, USA
| | - Leonora M Meisenbach
- Division of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA
- Department of Surgery and Cardiothoracic Surgery, Weill Cornell Medical College, Houston Methodist Hospital, Houston, TX, USA
| | - Ray Chihara
- Division of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA
- Department of Surgery and Cardiothoracic Surgery, Weill Cornell Medical College, Houston Methodist Hospital, Houston, TX, USA
| | - Edward Y Chan
- Division of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA
- Department of Surgery and Cardiothoracic Surgery, Weill Cornell Medical College, Houston Methodist Hospital, Houston, TX, USA
| | - Edward A Graviss
- Department of Pathology and Genomic Medicine, Houston Methodist Research Institute, Houston, TX, USA
- Department of Surgery, Houston Methodist Hospital, Houston, TX, USA
| | - Min P Kim
- Division of Thoracic Surgery, Department of Surgery, Houston Methodist Hospital, 6550 Fannin Street, Suite 1661, Houston, TX, 77030, USA.
- Department of Surgery and Cardiothoracic Surgery, Weill Cornell Medical College, Houston Methodist Hospital, Houston, TX, USA.
| |
Collapse
|
37
|
Stefanova DI, Limberg JN, Ullmann TM, Liu M, Thiesmeyer JW, Beninato T, Finnerty BM, Schnoll-Sussman FH, Katz PO, Fahey TJ, Zarnegar R. Quantifying Factors Essential to the Integrity of the Esophagogastric Junction During Antireflux Procedures. Ann Surg 2020; 272:488-494. [DOI: 10.1097/sla.0000000000004202] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
38
|
Experience-based expert consensus on the intra-operative usage of the Endoflip impedance planimetry system. Surg Endosc 2020; 35:2731-2742. [DOI: 10.1007/s00464-020-07704-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 06/09/2020] [Indexed: 02/06/2023]
|