1
|
van der Starre CM, Cremers-Pijpers SAJ, van Rossum C, Bowles EC, Tostmann A. The in situ efficacy of whole room disinfection devices: a literature review with practical recommendations for implementation. Antimicrob Resist Infect Control 2022; 11:149. [PMID: 36471395 PMCID: PMC9724435 DOI: 10.1186/s13756-022-01183-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 11/10/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Terminal cleaning and disinfection of hospital patient rooms must be performed after discharge of a patient with a multidrug resistant micro-organism to eliminate pathogens from the environment. Terminal disinfection is often performed manually, which is prone to human errors and therefore poses an increased infection risk for the next patients. Automated whole room disinfection (WRD) replaces or adds on to the manual process of disinfection and can contribute to the quality of terminal disinfection. While the in vitro efficacy of WRD devices has been extensively investigated and reviewed, little is known about the in situ efficacy in a real-life hospital setting. In this review, we summarize available literature on the in situ efficacy of WRD devices in a hospital setting and compare findings to the in vitro efficacy of WRD devices. Moreover, we offer practical recommendations for the implementation of WRD devices. METHODS The in situ efficacy was summarized for four commonly used types of WRD devices: aerosolized hydrogen peroxide, H2O2 vapour, ultraviolet C and pulsed xenon ultraviolet. The in situ efficacy was based on environmental and clinical outcome measures. A systematic literature search was performed in PubMed in September 2021 to identify available literature. For each disinfection system, we summarized the available devices, practical information, in vitro efficacy and in situ efficacy. RESULTS In total, 54 articles were included. Articles reporting environmental outcomes of WRD devices had large variation in methodology, reported outcome measures, preparation of the patient room prior to environmental sampling, the location of sampling within the room and the moment of sampling. For the clinical outcome measures, all included articles reported the infection rate. Overall, these studies consistently showed that automated disinfection using any of the four types of WRD is effective in reducing environmental and clinical outcomes. CONCLUSION Despite the large variation in the included studies, the four automated WRD systems are effective in reducing the amount of pathogens present in a hospital environment, which was also in line with conclusions from in vitro studies. Therefore, the assessment of what WRD device would be most suitable in a specific healthcare setting mostly depends on practical considerations.
Collapse
Affiliation(s)
- Caroline M. van der Starre
- grid.10417.330000 0004 0444 9382Unit of Hygiene and Infection Prevention, Department of Medical Microbiology, Radboud Center for Infectious Diseases (RCI), Radboudumc, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands
| | - Suzan A. J. Cremers-Pijpers
- grid.10417.330000 0004 0444 9382Unit of Hygiene and Infection Prevention, Department of Medical Microbiology, Radboud Center for Infectious Diseases (RCI), Radboudumc, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands
| | - Carsten van Rossum
- grid.10417.330000 0004 0444 9382Unit of Hygiene and Infection Prevention, Department of Medical Microbiology, Radboud Center for Infectious Diseases (RCI), Radboudumc, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands
| | - Edmée C. Bowles
- grid.10417.330000 0004 0444 9382Unit of Hygiene and Infection Prevention, Department of Medical Microbiology, Radboud Center for Infectious Diseases (RCI), Radboudumc, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands
| | - Alma Tostmann
- grid.10417.330000 0004 0444 9382Unit of Hygiene and Infection Prevention, Department of Medical Microbiology, Radboud Center for Infectious Diseases (RCI), Radboudumc, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands
| |
Collapse
|
2
|
Zhou Q, Rao F, Chen Z, Cheng Y, Zhang Q, Zhang J, Guan Z, He Y, Yu W, Cui G, Qi X, Hong W. The cwp66 Gene Affects Cell Adhesion, Stress Tolerance, and Antibiotic Resistance in Clostridioides difficile. Microbiol Spectr 2022; 10:e0270421. [PMID: 35357205 PMCID: PMC9045246 DOI: 10.1128/spectrum.02704-21] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 03/05/2022] [Indexed: 02/08/2023] Open
Abstract
Clostridioides difficile is a Gram-positive, spore-forming anaerobic bacteria that is one of the leading causes of antibiotic-associated diarrhea. The cell wall protein 66 gene (cwp66) encodes a cell wall protein, which is the second major cell surface antigen of C. difficile. Although immunological approaches, such as antibodies and purified recombinant proteins, have been implemented to study the role of Cwp66 in cell adhesion, no deletion mutant of the cwp66 gene has yet been characterized. We constructed a cwp66 gene deletion mutant using Clustered Regularly Interspaced Short Palindromic Repeats Cpf1 (CRISPR-Cpf1) system. The phenotypic and transcriptomic changes of the Δcwp66 mutant compared with the wild-type (WT) strain were studied. The deletion of the cwp66 gene led to the decrease of cell adhesive capacity, cell motility, and stresses tolerance (to Triton X-100, acidic environment, and oxidative stress). Interestingly, the Δcwp66 mutant is more sensitive than the WT strain to clindamycin, ampicillin, and erythromycin but more resistant than the latter to vancomycin and metronidazole. Moreover, mannitol utilization capability in the Δcwp66 mutant was lost. Comparative transcriptomic analyses indicated that (i) 22.90-fold upregulation of cwpV gene and unable to express gpr gene were prominent in the Δcwp66 mutant; (ii) the cwp66 gene was involved in vancomycin resistance of C. difficile by influencing the expression of d-Alanine-d-Alanine ligase; and (iii) the mannose/fructose/sorbose IIC and IID components were upregulated in Δcwp66 mutant. The present work deepens our understanding of the contribution of the cwp66 gene to cell adhesion, stress tolerance, antibiotic resistance, and mannitol transportation of C. difficile. IMPORTANCE The cell wall protein 66 gene (cwp66) encodes a cell wall protein, which is the second major cell surface antigen of C. difficile. Although immunological approaches, such as antibodies and purified recombinant proteins, have been implemented to study the role of Cwp66 in cell adhesion, no deletion mutant of the cwp66 gene has yet been characterized. The current study provides direct evidence that the cwp66 gene serves as a major adhesion in C. difficile, and also suggested that deletion of the cwp66 gene led to the decrease of cell adhesive capacity, cell motility, and stresses tolerance (to Triton X-100, acidic environment, and oxidative stress). Interestingly, the antibiotic resistance and carbon source utilization profiles of the Δcwp66 mutant were significantly changed. These phenotypes were detrimental to the survival and pathogenesis of C. difficile in the human gut and may shed light on preventing C. difficile infection.
Collapse
Affiliation(s)
- Qingshuai Zhou
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| | - Fengqin Rao
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| | - Zhenghong Chen
- Key Laboratory of Microbiology and Parasitology of Education Department of Guizhou, School of Basic Medical Science, Guizhou Medical University, Guiyang, Guizhou, China
| | - Yumei Cheng
- Department of Critical Care Medicine, the Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Qifang Zhang
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| | - Jie Zhang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, China
| | - Zhizhong Guan
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| | - Yan He
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| | - Wenfeng Yu
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| | - Guzhen Cui
- Key Laboratory of Microbiology and Parasitology of Education Department of Guizhou, School of Basic Medical Science, Guizhou Medical University, Guiyang, Guizhou, China
| | - Xiaolan Qi
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| | - Wei Hong
- Key Laboratory of Endemic and Ethnic Diseases, Ministry of Education & Key Laboratory of Medical Molecular Biology of Guizhou Province, Guizhou Medical University, Guiyang, Guizhou, China
| |
Collapse
|
3
|
Kruszewska E, Grześ H, Czupryna P, Pancewicz S, Groth M, Wondim M, Moniuszko-Malinowska A. Corrigendum: Fogging With Peracetic Acid in Schools and Kindergartens. Front Public Health 2022; 10:867618. [PMID: 35372218 PMCID: PMC8964362 DOI: 10.3389/fpubh.2022.867618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 02/03/2022] [Indexed: 11/22/2022] Open
Affiliation(s)
- Ewelina Kruszewska
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Henryk Grześ
- Microbiology Laboratory, University Clinical Hospital in Bialystok, Bialystok, Poland
| | - Piotr Czupryna
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Sławomir Pancewicz
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Monika Groth
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Mulugeta Wondim
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Anna Moniuszko-Malinowska
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| |
Collapse
|
4
|
Truitt CL, Runyan DA, Stern JJ, Tobin C, Goldwater W, Madsen R. Evaluation of an aerosolized hydrogen peroxide disinfection system for the reduction of Clostridioides difficile hospital infection rates over a 10 year period. Am J Infect Control 2022; 50:409-413. [PMID: 35307211 DOI: 10.1016/j.ajic.2021.11.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 11/25/2022]
Abstract
BACKGROUND Clostridioides difficile infections (CDI) cause significant morbidity and mortality in healthcare facilities worldwide. We examined the use of an aerosolized hydrogen peroxide (aHP) disinfection system for reduction of CDI rates. METHODS We conducted a retrospective analysis of CDI rates at an acute care facility over a 10-year period. The first 5-year period investigated the before and after implementation of an aHP system followed by another 5-year period of continued use on CDI rates. RESULTS The before and after period showed a reduction in CDI rates from 4.6 per 10,000 patient days down to 2.7 per 10,000 patient days after implementation (P < .001). The second study period for the continued aHP use exhibited a consistent decrease in CDI rates to 1.4 per 10,000 patient days at the end of the study. CONCLUSIONS The addition of a touchless aHP whole room disinfection system as part of terminal cleaning resulted in a significant reduction in CDI rates that have been sustained year after year.
Collapse
|
5
|
Kruszewska E, Grześ H, Czupryna P, Pancewicz S, Groth M, Wondim M, Moniuszko-Malinowska A. Fogging With Peracetic Acid in Schools and Kindergartens. Front Public Health 2021; 9:697917. [PMID: 34604154 PMCID: PMC8486081 DOI: 10.3389/fpubh.2021.697917] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 08/17/2021] [Indexed: 11/15/2022] Open
Abstract
Disinfection is a key element in controlling infections. Fogging, also known as fumigation, is one of the most effective chemical disinfection methods. Peracetic acid (PAA) is a powerful oxidant with bactericidal and fungicidal properties. The aim of this study is to determine the type of bacteria and fungi present in educational institutions and whether disinfection by PAA fumigation in these institutions is also effective and useful, as demonstrated previously in healthcare centers. This study was carried out in five kindergartens and five primary schools in Bialystok, Poland. Three rooms have been selected in each of these educational institutions, and the disinfection was carried out in 30 rooms in total. Fogging with PAA was performed in selected rooms. Before and after disinfection, samples were collected from four surfaces: walls, tables, doors, and chair backs. Most frequently detected microorganisms in schools and kindergartens were Micrococcus luteus (M. luteus), Staphylococcus warneri (S. warneri), Paracoccus yeei (P. yeei), Staphylococcus hominis ssp. hominis (S. hominis), Kocuria rhizophila (K. rhizophila), Kocuria rosea (K. rosea). In addition, Staphylococcus haemolyticus (S. haemolyticus), Acinetobacter lwoffii (A. lwoffii), Kocuria kristinae (K. kristinae), Lactococcus lactis ssp. lactis (L. lactis) were the most prevalent in kindergartens, whereas Kytococcus sedentarius (K. sedentarius) was the most prevalent in schools. Comparison of the bacterial flora of schools and kindergartens showed statistically significant differences in the prevalence of bacteria on different surfaces. A significant decrease in the number of colonies after disinfection was observed on all surfaces (p < 0.05). In addition, the calculated effectiveness of disinfection was 99.7% in kindergartens and 99.3% in schools. The results indicate that fogging of PAA is a highly effective method of surface disinfection in kindergartens and schools.
Collapse
Affiliation(s)
- Ewelina Kruszewska
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Henryk Grześ
- Microbiology Laboratory, University Clinical Hospital in Bialystok, Bialystok, Poland
| | - Piotr Czupryna
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Sławomir Pancewicz
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Monika Groth
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Mulugeta Wondim
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| | - Anna Moniuszko-Malinowska
- Department of Infectious Diseases and Neuroinfections, Medical University of Bialystok, Bialystok, Poland
| |
Collapse
|
6
|
Knobling B, Franke G, Klupp EM, Belmar Campos C, Knobloch JK. Evaluation of the Effectiveness of Two Automated Room Decontamination Devices Under Real-Life Conditions. Front Public Health 2021; 9:618263. [PMID: 33708756 PMCID: PMC7940181 DOI: 10.3389/fpubh.2021.618263] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 02/02/2021] [Indexed: 01/26/2023] Open
Abstract
To evaluate the effectiveness of automated room decontamination devices, a common aerosolized hydrogen peroxide (aHP) as well as a recent gaseous ozone-based device, which produces the disinfectant reagent without the need of consumables, were tested under real-life conditions. Twenty-two contaminated surfaces were positioned in different areas in a patient room with adjacent bathroom and anteroom. Following the decontamination process bacteria were recovered and reduction factors were calculated after performing quantitative culture. Following the manufactures instructions, the ozone-based device displayed a bactericidal effect (log10 > 5), whereas the aHP system failed for a high bacterial burden and achieves only a complete elimination of a realistic bioburden (log10 2). After increasing the exposure time to 30 min, the aHP device also reached a bactericidal effect. Nevertheless, our results indicate, that further research and development is necessary, to get knowledge about toxicity, efficacy and safety by using in complex hospital conditions and achieve meaningful integration in cleaning procedures, to reach positive effects on disinfection performance.
Collapse
Affiliation(s)
| | | | | | | | - Johannes K. Knobloch
- Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
7
|
Tarka P, Borowska-Solonynko A, Brzozowska M, Nitsch-Osuch A, Kanecki K, Kuthan R, Garczewska B. No-Touch Automated Room Disinfection after Autopsies of Exhumed Corpses. Pathogens 2020; 9:pathogens9080648. [PMID: 32806609 PMCID: PMC7460184 DOI: 10.3390/pathogens9080648] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 07/30/2020] [Accepted: 08/06/2020] [Indexed: 12/21/2022] Open
Abstract
Autopsies of exhumed bodies pose a risk of infections with environmental bacteria or fungi, which may be life-threatening. Thus, it is important to use effective methods of disinfection in forensic pathology facilities. In this study, we investigated the effectiveness of no-touch automated disinfection (NTD) system after autopsies of exhumed bodies. Directly after 11 autopsies of exhumed bodies, we used an NTD system based on a peroxone vapor to disinfect the air and surfaces. We measured microbial burden in the air and on surfaces before and after NTD. The NTD system reduced the mean bacterial burden in the air from 171 colony forming units (CFU)/m3 to 3CFU/m3. The mean fungal burden in the air decreased from 221 CFU/m3 to 9CFU/m3. The mean all-surface microbial burden was 79 CFU/100 cm2 after all autopsies, and it decreased to 2 CFU/100 cm2 after NTD. In conclusion, the peroxone-based NTD system was effective for decontamination of the air and surfaces in a dissecting room after autopsies of exhumed bodies.
Collapse
Affiliation(s)
- Patryk Tarka
- Department of Social Medicine and Public Health; Medical University of Warsaw, 3 Oczki St., 02-007 Warsaw, Poland; (A.N.-O.); (K.K.)
- Correspondence:
| | - Aleksandra Borowska-Solonynko
- Department of Forensic Medicine, Medical University of Warsaw, 1 Oczki st., 02-007 Warsaw, Poland; (A.B.-S.); (M.B.)
| | - Małgorzata Brzozowska
- Department of Forensic Medicine, Medical University of Warsaw, 1 Oczki st., 02-007 Warsaw, Poland; (A.B.-S.); (M.B.)
| | - Aneta Nitsch-Osuch
- Department of Social Medicine and Public Health; Medical University of Warsaw, 3 Oczki St., 02-007 Warsaw, Poland; (A.N.-O.); (K.K.)
| | - Krzysztof Kanecki
- Department of Social Medicine and Public Health; Medical University of Warsaw, 3 Oczki St., 02-007 Warsaw, Poland; (A.N.-O.); (K.K.)
| | - Robert Kuthan
- Chair and Department of Medical Microbiology, Medical University of Warsaw, 5 Chalubinski st., 02-004 Warsaw, Poland;
| | - Barbara Garczewska
- Laboratory of Mycology, Institute of Tuberculosis and Lung Diseases, 26 Płocka st., 01-138 Warsaw, Poland;
| |
Collapse
|
8
|
Clinical and Microbiological Effects of Weekly Supragingival Irrigation with Aerosolized 0.5% Hydrogen Peroxide and Formation of Cavitation Bubbles in Gingival Tissues after This Irrigation: A Six-Month Randomized Clinical Trial. OXIDATIVE MEDICINE AND CELLULAR LONGEVITY 2020; 2020:3852431. [PMID: 32802264 PMCID: PMC7415088 DOI: 10.1155/2020/3852431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 06/08/2020] [Accepted: 07/07/2020] [Indexed: 11/30/2022]
Abstract
Introduction The study investigated the effect of weekly supragingival irrigation with aerosolized 0.5% hydrogen peroxide (H2O2) solution as a maintenance periodontal therapy on clinical and microbiological parameters in patients with chronic periodontitis. The other purpose was to investigate whether cavitation bubbles can penetrate not only into periodontitis-damaged tissues but also into ex vivo porcine healthy periodontal tissues. Materials and Methods The study included 35 systemically healthy patients with chronic periodontitis (CP). After nonsurgical periodontal debridement (NSPD), all patients were randomized into two groups: the Control group (NSDP alone, n = 18) and the Test group (NSDP plus supragingival irrigation, n = 17). Clinical (Approximal Plaque Index (API), Bleeding Index (BI), and Modified Gingival Index (MGI)) and microbiological (Polymerase Chain Reaction technology (using a micro-IDent® kit)) measurements were performed at the initial time point, 3 months, and 6 months after NSPD. The impact of supragingival irrigation on diseased gingival tissues of CP patients (n = 5) and on ex vivo porcine healthy gingival tissue samples (n = 3) was evaluated to estimate morphological changes in healthy and diseased gingival tissues. Results Morphological data revealed that supragingival irrigation caused the formation of cavitation bubbles in diseased gingival tissue of CP patients and in healthy porcine gingival tissues. The decrease in API, BI, and MGI scores after 6 months in the Test group significantly (p ≤ 0.01, p ≤ 0.05, and p ≤ 0.01, respectively) exceeded that in the Control group. Test group patients demonstrated a decrease in periodontal sites showing Pocket Probing Depth > 4 mm and, after 6 months, a statistically significant decrease in the proportion of periopathogenic bacteria. Conclusion The effectiveness of mechanical periodontal treatment combined with weekly supragingival irrigation with aerosolized 0.5% H2O2 solution on clinical and microbiological parameters of periodontal tissues of periodontitis patients is reliably higher than that of mechanical periodontal debridement alone. It has been found that cavitation bubbles as a result of irrigation with the aerosolized 0.5% hydrogen peroxide solution can form not only in periodontal tissues of periodontitis patients but also in ex vivo porcine healthy gingival tissues.
Collapse
|
9
|
Stuart J, Chewins J, Tearle J. Comparing the Efficacy of Formaldehyde with Hydrogen Peroxide Fumigation on Infectious Bronchitis Virus. APPLIED BIOSAFETY 2020; 25:83-89. [PMID: 34191920 PMCID: PMC7307011 DOI: 10.1177/1535676020909998] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The recent reclassification of formaldehyde as a presumed carcinogen prompted the investigation into the comparative efficacy of hydrogen peroxide as a fumigant in microbiological safety cabinets. INTRODUCTION The aim of the study was to quantify the biocidal efficacy of formaldehyde fumigation, including variables such as exposure time and concentration, and then to compare this to the biocidal efficacy achieved from a hydrogen peroxide vapor fumigation system. The study also investigated the ability of both fumigants to permeate the microbiological safety cabinet (MBSC), including the workspace, under the work tray, and after the HEPA filters. Furthermore, the effect of organic soiling on efficacy was also assessed. Infectious bronchitis virus (IBV) was used as the biological target to develop this study model. METHODS A model using IBV was developed to determine the efficacy of formaldehyde and hydrogen peroxide as fumigants. Virus was dried on stainless steel discs, and variables including concentration, time, protein soiling, and location within an MBSC were assessed. RESULTS It was demonstrated that formaldehyde fumigation could achieve a 6-log reduction in the titer of the virus throughout the cabinet, and high protein soiling in the presentation did not affect efficacy. Appropriate cycle parameters for the hydrogen peroxide system were developed, and when challenged with IBV, it was shown that vaporized hydrogen peroxide could achieve an equal 6-log titer reduction as formaldehyde within the cabinet workspace and overcome the presence of soiling. CONCLUSION Hydrogen peroxide was demonstrated to be a viable alternative to formaldehyde under most situations tested. However, the hydrogen peroxide system did not achieve an equal titer reduction above the cabinet's first HEPA filter using the cabinet workspace cycle, and further optimization of the hydrogen peroxide cycle parameters, including pulsing of the cabinet fans, may be required to achieve this.
Collapse
|
10
|
Otter J, Yezli S, Barbut F, Perl T. An overview of automated room disinfection systems: When to use them and how to choose them. DECONTAMINATION IN HOSPITALS AND HEALTHCARE 2020. [PMCID: PMC7153347 DOI: 10.1016/b978-0-08-102565-9.00015-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Conventional disinfection methods are limited by reliance on the operator to ensure appropriate selection, formulation, distribution, and contact time of the agent. Automated room disinfection (ARD) systems remove or reduce reliance on operators and so they have the potential to improve the efficacy of terminal disinfection. The most commonly used systems are hydrogen peroxide vapor (H2O2 vapor), aerosolized hydrogen peroxide (aHP), and ultraviolet (UV) light. These systems have important differences in their active agent, delivery mechanism, efficacy, process time, and ease of use. The choice of ARD system should be influenced by the intended application, the evidence base for effectiveness, practicalities of implementation, and cost considerations.
Collapse
Affiliation(s)
- J.A. Otter
- NIHR Health Protection Research Unit (HPRU) in HCAIs and AMR at Imperial College London, and Imperial College Healthcare NHS Trust, Infection Prevention and Control, London, United Kingdom
| | - S. Yezli
- Global Centre for Mass Gatherings Medicine, WHO Collaborating Centre for Mass Gatherings Medicine, Ministry of Health-Public Health Directorate, Riyadh, Kingdom of Saudi Arabia
| | - F. Barbut
- National Reference Laboratory for C. difficile, Infection Control Unit, Hôpital Saint Antoine, Paris, France,INSERM S-1139, Faculté de Pharmacie de Paris, Université de Paris, Paris, France
| | - T.M. Perl
- Infectious Diseases and Geographic Medicine, UT Southwestern Medical Center, Dallas, TX, United States
| |
Collapse
|
11
|
Freyssenet C, Karlen S. Plasma-Activated Aerosolized Hydrogen Peroxide (aHP) in Surface Inactivation Procedures. APPLIED BIOSAFETY 2019; 24:10-19. [PMID: 36034636 PMCID: PMC9093241 DOI: 10.1177/1535676018818559] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
Introduction Hydrogen peroxide is a strong oxidant that possesses an antimicrobial activity. It has been successfully used in surface/room decontamination processes either under the form of hydrogen peroxide vapor (HPV) or of vaporized hydrogen peroxide (VHP). Aerosolized hydrogen peroxide (aHP) offers a third alternative. The technology relies on the dispersion of aerosols of a hydrogen peroxide solution often complemented with silver cations. aHP provides an inexpensive and safe approach to treat contaminated rooms but sometimes fails to achieve the 6-log10 reduction limit in the number of viable microorganisms. Methods Here, we used a venturi-based aHP generator that generates 4 mm in size aerosols from a 12% plasma-activated hydrogen peroxide solution free of silver cations. Results & Discussion We could successfully and constantly inactivate bacterial growth from biological indicators containing at least 106 spores of Geobacillus stearothermophilus placed on stainless steel discs wrapped in Tyvek pouches. We could also show that the biological indicators placed at various locations in a class II biosafety cabinet were equally inactivated, showing that hydrogen peroxide aerosols migrate through HEPA filters. Conclusions Considering that our method for aerosol generation is simple, reproducible, and highly effective at inactivating spores, our approach is expected to serve as a relatively cost effective alternative method for disinfecting potentially contaminated rooms or surfaces.
Collapse
Affiliation(s)
- Camille Freyssenet
- Swiss Federal Institute of Technology Lausanne, EPFL RHO DSPS, Lausanne, Switzerland
| | - Stéphane Karlen
- Swiss Federal Institute of Technology Lausanne, EPFL RHO DSPS, Lausanne, Switzerland
| |
Collapse
|
12
|
Edwards AN, Karim ST, Pascual RA, Jowhar LM, Anderson SE, McBride SM. Chemical and Stress Resistances of Clostridium difficile Spores and Vegetative Cells. Front Microbiol 2016; 7:1698. [PMID: 27833595 PMCID: PMC5080291 DOI: 10.3389/fmicb.2016.01698] [Citation(s) in RCA: 81] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Accepted: 10/12/2016] [Indexed: 12/11/2022] Open
Abstract
Clostridium difficile is a Gram-positive, sporogenic and anaerobic bacterium that causes a potentially fatal colitis. C. difficile enters the body as dormant spores that germinate in the colon to form vegetative cells that secrete toxins and cause the symptoms of infection. During transit through the intestine, some vegetative cells transform into spores, which are more resistant to killing by environmental insults than the vegetative cells. Understanding the inherent resistance properties of the vegetative and spore forms of C. difficile is imperative for the development of methods to target and destroy the bacterium. The objective of this study was to define the chemical and environmental resistance properties of C. difficile vegetative cells and spores. We examined vegetative cell and spore tolerances of three C. difficile strains, including 630Δerm, a 012 ribotype and a derivative of a past epidemic strain; R20291, a 027 ribotype and current epidemic strain; and 5325, a clinical isolate that is a 078 ribotype. All isolates were tested for tolerance to ethanol, oxygen, hydrogen peroxide, butanol, chloroform, heat and sodium hypochlorite (household bleach). Our results indicate that 630Δerm vegetative cells (630 spo0A) are more resistant to oxidative stress than those of R20291 (R20291 spo0A) and 5325 (5325 spo0A). In addition, 5325 spo0A vegetative cells exhibited greater resistance to organic solvents. In contrast, 630Δerm spores were more sensitive than R20291 or 5325 spores to butanol. Spores from all three strains exhibited high levels of resistance to ethanol, hydrogen peroxide, chloroform and heat, although R20291 spores were more resistant to temperatures in the range of 60-75°C. Finally, household bleach served as the only chemical reagent tested that consistently reduced C. difficile vegetative cells and spores of all tested strains. These findings establish conditions that result in vegetative cell and spore elimination and illustrate the resistance of C. difficile to common decontamination methods. These results further demonstrate that the vegetative cells and spores of various C. difficile strains have different resistance properties that may impact decontamination of surfaces and hands.
Collapse
Affiliation(s)
- Adrianne N Edwards
- Emory Antibiotic Resistance Center, Department of Microbiology and Immunology, Emory University School of Medicine, Atlanta GA, USA
| | - Samiha T Karim
- Emory Antibiotic Resistance Center, Department of Microbiology and Immunology, Emory University School of Medicine, Atlanta GA, USA
| | - Ricardo A Pascual
- Emory Antibiotic Resistance Center, Department of Microbiology and Immunology, Emory University School of Medicine, Atlanta GA, USA
| | - Lina M Jowhar
- Emory Antibiotic Resistance Center, Department of Microbiology and Immunology, Emory University School of Medicine, Atlanta GA, USA
| | - Sarah E Anderson
- Emory Antibiotic Resistance Center, Department of Microbiology and Immunology, Emory University School of Medicine, Atlanta GA, USA
| | - Shonna M McBride
- Emory Antibiotic Resistance Center, Department of Microbiology and Immunology, Emory University School of Medicine, Atlanta GA, USA
| |
Collapse
|
13
|
Žekonis G, Žekonis J, Gleiznys A, Noreikienė V, Balnytė I, Šadzevičienė R, Narbutaitė J. Effect of Supragingival Irrigation with Aerosolized 0.5% Hydrogen Peroxide on Clinical Periodontal Parameters, Markers of Systemic Inflammation, and Morphology of Gingival Tissues in Patients with Periodontitis. Med Sci Monit 2016; 22:3713-3721. [PMID: 27743448 PMCID: PMC5070619 DOI: 10.12659/msm.900338] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND Various studies have shown that non-surgical periodontal treatment is correlated with reduction in clinical parameters and plasma levels of inflammatory markers. The aim of this study was to evaluate the effect of long-term weekly supragingival irrigations with aerosolized 0.5% hydrogen peroxide as maintenance therapy followed by non-surgical periodontal treatment on clinical parameters, plasma levels of inflammatory markers, and morphological changes in gingival tissues of patients with periodontitis. MATERIAL AND METHODS In total, 43 patients with chronic periodontitis were randomly allocated to long-term maintenance therapy. The patients' periodontal status was assessed using clinical parameters of approximal plaque index, modified gingival index, bleeding index, pocket probing depth, and plasma levels of inflammatory markers (high-sensitivity C-reactive protein and white blood cell count) at baseline and after 1, 2, and 3 years. The morphological status of gingival tissues (immediately after supragingival irrigation) was assessed microscopically. RESULTS Complete data were obtained on 34 patients. A highly statistically significant and consistent reduction was observed in all long-term clinical parameters and plasma levels of inflammatory markers. Morphological data showed abundant spherical bubbles in gingival tissues. CONCLUSIONS 1. The present study showed that non-surgical periodontal treatment with long-term weekly supragingival irrigations with aerosolized 0.5% hydrogen peroxide improved clinical periodontal status and plasma levels of inflammatory markers and may be a promising method in periodontology. 2. We found that supragingival irrigation with aerosolized 0.5% hydrogen peroxide created large numbers of spherical bubbles in gingival tissues.
Collapse
Affiliation(s)
- Gediminas Žekonis
- Clinic of Dental and Maxillofacial Orthopedics, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Jonas Žekonis
- Clinic of Dental and Maxillofacial Orthopedics, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Alvydas Gleiznys
- Clinic of Dental and Maxillofacial Orthopedics, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Viktorija Noreikienė
- Clinic of Dental and Maxillofacial Orthopedics, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Ingrida Balnytė
- Department of Histology and Embryology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Renata Šadzevičienė
- Clinic of Dental and Oral Pathology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Julija Narbutaitė
- Clinic of Oral Health and Pediatric Dentistry, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
14
|
Touchless Technologies for Decontamination in the Hospital: a Review of Hydrogen Peroxide and UV Devices. Curr Infect Dis Rep 2015; 17:498. [DOI: 10.1007/s11908-015-0498-1] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
15
|
Morin T, Martin H, Soumet C, Fresnel R, Lamaudière S, Le Sauvage A, Deleurme K, Maris P. Comparison of the virucidal efficacy of peracetic acid, potassium monopersulphate and sodium hypochlorite on bacteriophages P001 and MS2. J Appl Microbiol 2015; 119:655-65. [DOI: 10.1111/jam.12870] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 05/15/2015] [Accepted: 05/29/2015] [Indexed: 01/21/2023]
Affiliation(s)
- T. Morin
- French Agency for Food; Environmental and Occupational Health & Safety; Ploufragan-Plouzané Laboratory; Viral Fish Pathology Unit; Université Européenne de Bretagne; Technopôle Brest Iroise; Plouzané France
- ACTALIA; Sécurité des Aliments; Villers Bocage France
| | - H. Martin
- French Agency for Food, Environmental and Occupational Health & Safety; Fougères Laboratory, Cedex France
| | - C. Soumet
- French Agency for Food, Environmental and Occupational Health & Safety; Fougères Laboratory, Cedex France
| | - R. Fresnel
- French Agency for Food, Environmental and Occupational Health & Safety; Fougères Laboratory, Cedex France
| | - S. Lamaudière
- French Agency for Food, Environmental and Occupational Health & Safety; Fougères Laboratory, Cedex France
| | | | - K. Deleurme
- French Agency for Food, Environmental and Occupational Health & Safety; Fougères Laboratory, Cedex France
| | - P. Maris
- French Agency for Food, Environmental and Occupational Health & Safety; Fougères Laboratory, Cedex France
| |
Collapse
|