• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4616374)   Today's Articles (686)   Subscriber (49394)
For: Dong Y, Shi AJ, Wu JL, Wang RX, Sun LF, Liu AL, Liu YJ. Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT. Eur Spine J 2016;25:1754-63. [DOI: 10.1007/s00586-015-4053-4] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2014] [Revised: 04/29/2015] [Accepted: 06/04/2015] [Indexed: 10/23/2022]
Number Cited by Other Article(s)
1
Robar JL, Cherpak A, MacDonald RL, Yashayaeva A, McAloney D, McMaster N, Zhan K, Cwajna S, Patil N, Dahn H. Novel Technology Allowing Cone Beam Computed Tomography in 6 Seconds: A Patient Study of Comparative Image Quality. Pract Radiat Oncol 2024;14:277-286. [PMID: 37939844 DOI: 10.1016/j.prro.2023.10.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 10/20/2023] [Accepted: 10/30/2023] [Indexed: 11/10/2023]
2
Lenham FM, Iball GR. Improving the quality of computed tomography brain images in the presence of cochlear implant induced metal artefacts through the additional use of tissue mimicking materials alongside metal artefact reduction software. Radiography (Lond) 2024;30:813-820. [PMID: 38513334 DOI: 10.1016/j.radi.2024.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 02/15/2024] [Accepted: 03/08/2024] [Indexed: 03/23/2024]
3
Morioka Y, Ichikawa K, Kawashima H. Quality improvement of images with metal artifact reduction using a noise recovery technique in computed tomography. Phys Eng Sci Med 2024;47:169-180. [PMID: 37938518 DOI: 10.1007/s13246-023-01353-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 10/31/2023] [Indexed: 11/09/2023]
4
Selles M, van Osch JAC, Maas M, Boomsma MF, Wellenberg RHH. Advances in metal artifact reduction in CT images: A review of traditional and novel metal artifact reduction techniques. Eur J Radiol 2024;170:111276. [PMID: 38142571 DOI: 10.1016/j.ejrad.2023.111276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/14/2023] [Accepted: 12/18/2023] [Indexed: 12/26/2023]
5
Nemoto H, Saito M, Suzuki T, Suzuki H, Sano N, Mochizuki Z, Mochizuki K, Ueda K, Komiyama T, Marino K, Aoki S, Oguri M, Takahashi H, Onishi H. Evaluation of computed tomography metal artifact and CyberKnife fiducial recognition for novel size fiducial markers. J Appl Clin Med Phys 2023;24:e14142. [PMID: 37672211 PMCID: PMC10691645 DOI: 10.1002/acm2.14142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 06/28/2023] [Accepted: 08/19/2023] [Indexed: 09/07/2023]  Open
6
Popp D, Sinzinger AX, Decker JA, Braun F, Bette S, Risch F, Haerting M, Garthe T, Scheurig-Muenkler C, Kroencke TJ, Schwarz F. Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets. Eur J Radiol 2023;165:110946. [PMID: 37399668 DOI: 10.1016/j.ejrad.2023.110946] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 06/12/2023] [Accepted: 06/19/2023] [Indexed: 07/05/2023]
7
Dunning CAS, Rajendran K, Inoue A, Rajiah P, Weber N, Fletcher JG, McCollough CH, Leng S. Optimal Virtual Monoenergetic Photon Energy (keV) for Photon-Counting-Detector Computed Tomography Angiography. J Comput Assist Tomogr 2023;47:569-575. [PMID: 36790898 PMCID: PMC10349687 DOI: 10.1097/rct.0000000000001450] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
8
Chang CH, Wu HN, Hsu CH, Lin HH. Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography. PLoS One 2023;18:e0282900. [PMID: 36913430 PMCID: PMC10010526 DOI: 10.1371/journal.pone.0282900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 02/25/2023] [Indexed: 03/14/2023]  Open
9
Metal implants on abdominal CT: does split-filter dual-energy CT provide additional value over iterative metal artifact reduction? Abdom Radiol (NY) 2023;48:424-435. [PMID: 36180598 PMCID: PMC9849167 DOI: 10.1007/s00261-022-03682-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 09/09/2022] [Accepted: 09/09/2022] [Indexed: 01/27/2023]
10
Kawasaki T, Kikuchi T, Otani K, Mitsuno Y, Yamao Y, Sawamoto N, Takahashi R, Miyamoto S. Intraoperative cone-beam CT with metal artifact reduction for assessment of the electrode position and the intracranial structures during deep brain stimulation procedure. Acta Neurochir (Wien) 2022;164:2309-2316. [PMID: 35851925 DOI: 10.1007/s00701-022-05313-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 07/08/2022] [Indexed: 12/14/2022]
11
Tran NA, Sodickson AD, Gupta R, Potter CA. Clinical applications of dual-energy computed tomography in neuroradiology. Semin Ultrasound CT MR 2022;43:280-292. [PMID: 35738814 DOI: 10.1053/j.sult.2022.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
12
Zhao X, Chao W, Shan Y, Li J, Zhao C, Zhang M, Lu J. Comparison of Image Quality and Radiation Dose Between Single-Energy and Dual-Energy Images for the Brain With Stereotactic Frames on Dual-Energy Cerebral CT. FRONTIERS IN RADIOLOGY 2022;2:899100. [PMID: 37492654 PMCID: PMC10364999 DOI: 10.3389/fradi.2022.899100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 05/10/2022] [Indexed: 07/27/2023]
13
Kawauchi S, Chida K, Hamada Y, Tsuruta W. Lens dose reduction with a bismuth shield in neuro cone-beam computed tomography: an investigation on optimum shield device placement conditions. Radiol Phys Technol 2021;15:25-36. [PMID: 34796447 DOI: 10.1007/s12194-021-00644-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 11/08/2021] [Accepted: 11/09/2021] [Indexed: 11/26/2022]
14
van Ommen F, Kauw F, Bennink E, Heit JJ, Wolman DN, Dankbaar JW, de Jong HWAM, Wintermark M. Image Quality of Virtual Monochromatic Reconstructions of Noncontrast CT on a Dual-Source CT Scanner in Adult Patients. Acad Radiol 2021;28:e323-e330. [PMID: 32616420 DOI: 10.1016/j.acra.2020.05.038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 05/13/2020] [Accepted: 05/30/2020] [Indexed: 12/26/2022]
15
Exploring the best monochromatic energy level in dual energy spectral imaging for coronary stents after percutaneous coronary intervention. Sci Rep 2021;11:17576. [PMID: 34475491 PMCID: PMC8413443 DOI: 10.1038/s41598-021-97035-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Accepted: 08/17/2021] [Indexed: 11/27/2022]  Open
16
Puvanasunthararajah S, Fontanarosa D, Wille M, Camps SM. The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review. J Appl Clin Med Phys 2021;22:198-223. [PMID: 33938608 PMCID: PMC8200502 DOI: 10.1002/acm2.13255] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/21/2021] [Accepted: 03/30/2021] [Indexed: 12/22/2022]  Open
17
Radioprotection of eye lens using protective material in neuro cone-beam computed tomography: Estimation of dose reduction rate and image quality. Phys Med 2021;82:192-199. [PMID: 33647602 DOI: 10.1016/j.ejmp.2021.02.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 01/02/2021] [Accepted: 02/07/2021] [Indexed: 11/22/2022]  Open
18
Gupta A, Obmann VC, Jordan M, Lennartz S, Obmann MM, Große Hokamp N, Zopfs D, Pennig L, Fürtjes G, Ramaiya N, Gilkeson R, Laukamp KR. CT artifacts after contrast media injection in chest imaging: evaluation of post-processing algorithms, virtual monoenergetic images and their combination for artifact reduction. Quant Imaging Med Surg 2021;11:226-239. [PMID: 33392024 DOI: 10.21037/qims-20-435] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
19
Ishikawa T, Suzuki S, Harashima S, Fukui R, Kaiume M, Katada Y. Metal artifacts reduction in computed tomography: A phantom study to compare the effectiveness of metal artifact reduction algorithm, model-based iterative reconstruction, and virtual monochromatic imaging. Medicine (Baltimore) 2020;99:e23692. [PMID: 33327359 PMCID: PMC7738054 DOI: 10.1097/md.0000000000023692] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]  Open
20
Washio H, Ohira S, Funama Y, Morimoto M, Wada K, Yagi M, Shimamoto H, Koike Y, Ueda Y, Karino T, Inui S, Nitta Y, Miyazaki M, Teshima T. Metal artifact reduction using iterative CBCT reconstruction algorithm for head and neck radiation therapy: A phantom and clinical study. Eur J Radiol 2020;132:109293. [DOI: 10.1016/j.ejrad.2020.109293] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 08/26/2020] [Accepted: 09/16/2020] [Indexed: 10/23/2022]
21
Performance of single-energy metal artifact reduction in cardiac computed tomography: A clinical and phantom study. J Cardiovasc Comput Tomogr 2020;14:510-515. [DOI: 10.1016/j.jcct.2020.04.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 04/01/2020] [Accepted: 04/13/2020] [Indexed: 12/11/2022]
22
Barreto I, Pepin E, Davis I, Dean C, Massini T, Rees J, Olguin C, Quails N, Correa N, Rill L, Arreola M. Comparison of metal artifact reduction using single-energy CT and dual-energy CT with various metallic implants in cadavers. Eur J Radiol 2020;133:109357. [PMID: 33126172 DOI: 10.1016/j.ejrad.2020.109357] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 09/15/2020] [Accepted: 10/12/2020] [Indexed: 12/27/2022]
23
Koike Y, Anetai Y, Takegawa H, Ohira S, Nakamura S, Tanigawa N. Deep learning-based metal artifact reduction using cycle-consistent adversarial network for intensity-modulated head and neck radiation therapy treatment planning. Phys Med 2020;78:8-14. [DOI: 10.1016/j.ejmp.2020.08.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 08/17/2020] [Accepted: 08/18/2020] [Indexed: 01/27/2023]  Open
24
Wang G, Wang Z, Jin Z. A Novel Metallic Artifact Reduction Technique When Using a Computed Tomography-Guided Percutaneous Metallic Antenna to Ablate Malignant Pulmonary Nodules: A Qualitative and Quantitative Assessment. Med Sci Monit 2020;26:e923541. [PMID: 32525133 PMCID: PMC7304313 DOI: 10.12659/msm.923541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]  Open
25
Große Hokamp N, Eck B, Siedek F, Pinto Dos Santos D, Holz JA, Maintz D, Haneder S. Quantification of metal artifacts in computed tomography: methodological considerations. Quant Imaging Med Surg 2020;10:1033-1044. [PMID: 32489927 DOI: 10.21037/qims.2020.04.03] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
26
Laukamp KR, Große Hokamp N, Alabar O, Obmann VC, Lennartz S, Zopfs D, Gilkeson R, Ramaiya N, Gupta A. Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction. Clin Imaging 2020;60:249-256. [DOI: 10.1016/j.clinimag.2019.12.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 12/22/2019] [Accepted: 12/27/2019] [Indexed: 10/25/2022]
27
Do TD, Heim J, Melzig C, Vollherbst DF, Kauczor HU, Skornitzke S, Sommer CM. Virtual monochromatic spectral imaging versus linearly blended dual-energy and single-energy imaging during CT-guided biopsy needle positioning: Optimization of keV settings and impact on image quality. PLoS One 2020;15:e0228578. [PMID: 32040496 PMCID: PMC7010258 DOI: 10.1371/journal.pone.0228578] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 01/17/2020] [Indexed: 01/08/2023]  Open
28
Nagayama Y, Tanoue S, Oda S, Sakabe D, Emoto T, Kidoh M, Uetani H, Sasao A, Nakaura T, Ikeda O, Yamada K, Yamashita Y. Metal Artifact Reduction in Head CT Performed for Patients with Deep Brain Stimulation Devices: Effectiveness of a Single-Energy Metal Artifact Reduction Algorithm. AJNR Am J Neuroradiol 2020;41:231-237. [PMID: 31879332 DOI: 10.3174/ajnr.a6375] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 11/15/2019] [Indexed: 11/07/2022]
29
Nair JR, Burrows C, Jerome S, Ribeiro L, Larrazabal R, Gupta R, Yu E. Dual energy CT: a step ahead in brain and spine imaging. Br J Radiol 2020;93:20190872. [PMID: 31944834 DOI: 10.1259/bjr.20190872] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]  Open
30
Dual-Energy and Iterative Metal Artifact Reduction for Reducing Artifacts Due to Metallic Hardware: A Loosening Hip Phantom Study. AJR Am J Roentgenol 2019;212:1106-1111. [PMID: 30835522 DOI: 10.2214/ajr.18.20413] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
31
Zeng Y, Deng K, Yang H, Tan Y, Liu J, Geng D, Zhang J. Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2019;28:1783-1792. [PMID: 31041597 DOI: 10.1007/s00586-019-05984-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 04/09/2019] [Accepted: 04/19/2019] [Indexed: 10/26/2022]
32
Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts. Eur Radiol 2019;29:4228-4238. [PMID: 30649598 DOI: 10.1007/s00330-018-5928-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Revised: 11/06/2018] [Accepted: 11/28/2018] [Indexed: 10/27/2022]
33
Metal Artifact Reduction in Routine Chest and Abdominal Examinations Using Virtual Monoenergetic Images From Spectral Detector Computed Tomography. J Comput Assist Tomogr 2019;43:713-717. [DOI: 10.1097/rct.0000000000000901] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
34
Clinical Assessment of Metal Artifact Reduction Methods in Dual-Energy CT Examinations of Instrumented Spines. AJR Am J Roentgenol 2018;212:395-401. [PMID: 30667317 DOI: 10.2214/ajr.18.19757] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
35
Zhu L, Chen Y, Yang J, Tao X, Xi Y. Evaluation of the dental spectral cone beam CT for metal artefact reduction. Dentomaxillofac Radiol 2018;48:20180044. [PMID: 30299983 DOI: 10.1259/dmfr.20180044] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]  Open
36
Metal Artifact Reduction in Virtual Monoenergetic Spectral Dual-Energy CT of Patients With Metallic Orthopedic Implants in the Distal Radius. AJR Am J Roentgenol 2018;211:1083-1091. [PMID: 30240300 DOI: 10.2214/ajr.18.19514] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
37
The Optimal Energy Level of Virtual Monochromatic Images From Spectral CT for Reducing Beam-Hardening Artifacts Due to Contrast Media in the Thorax. AJR Am J Roentgenol 2018;211:557-563. [DOI: 10.2214/ajr.17.19377] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
38
Fukuda T, Fukuda K. The Role of Dual-Energy Computed Tomography in Musculoskeletal Imaging. PET Clin 2018;13:567-578. [PMID: 30219188 DOI: 10.1016/j.cpet.2018.05.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
39
Wellenberg RHH, Hakvoort ET, Slump CH, Boomsma MF, Maas M, Streekstra GJ. Metal artifact reduction techniques in musculoskeletal CT-imaging. Eur J Radiol 2018;107:60-69. [PMID: 30292274 DOI: 10.1016/j.ejrad.2018.08.010] [Citation(s) in RCA: 81] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 07/02/2018] [Accepted: 08/11/2018] [Indexed: 01/02/2023]
40
Yue D, Fan Rong C, Ning C, Liang H, Ai Lian L, Ru Xin W, Ya Hong L. Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifact reduction software. Acta Radiol 2018;59:853-860. [PMID: 28899125 DOI: 10.1177/0284185117731475] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
41
Reduction of Artifacts Caused by Deep Brain Stimulating Electrodes in Cranial Computed Tomography Imaging by Means of Virtual Monoenergetic Images, Metal Artifact Reduction Algorithms, and Their Combination. Invest Radiol 2018;53:424-431. [DOI: 10.1097/rli.0000000000000460] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
42
Laukamp KR, Lennartz S, Neuhaus VF, Große Hokamp N, Rau R, Le Blanc M, Abdullayev N, Mpotsaris A, Maintz D, Borggrefe J. CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar. Eur Radiol 2018;28:4524-4533. [PMID: 29725834 DOI: 10.1007/s00330-018-5414-2] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Revised: 02/22/2018] [Accepted: 02/27/2018] [Indexed: 11/26/2022]
43
Takada K, Ichikawa K, Banno S, Otobe K. [Suggestion of the Relative Artifact Index for Noise-independent Evaluation of the Streak Artifact]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2018;74:315-325. [PMID: 29681598 DOI: 10.6009/jjrt.2018_jsrt_74.4.315] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
44
Nishitani T, Matsugi K, Kitano T, Yamamoto H, Kaneko M, Yamada S. [Improvement of CT Imaging with a Metal Artifact Reduction Technique for Radiation Treatment Planning-Fundamental Study of Structure Delineation and Dose Calculation]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2018;74:39-47. [PMID: 29353835 DOI: 10.6009/jjrt.2018_jsrt_74.1.39] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
45
Wellenberg RHH, Donders JCE, Kloen P, Beenen LFM, Kleipool RP, Maas M, Streekstra GJ. Exploring metal artifact reduction using dual-energy CT with pre-metal and post-metal implant cadaver comparison: are implant specific protocols needed? Skeletal Radiol 2018;47:839-845. [PMID: 28842739 PMCID: PMC5915501 DOI: 10.1007/s00256-017-2750-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Revised: 07/26/2017] [Accepted: 08/01/2017] [Indexed: 02/02/2023]
46
Wang T, Ishihara T, Kono A, Yoshida N, Akasaka H, Mukumoto N, Yada R, Ejima Y, Yoshida K, Miyawaki D, Kakutani K, Nishida K, Negi N, Minami T, Aoyama Y, Takahashi S, Sasaki R. Application of dual-energy CT to suppression of metal artefact caused by pedicle screw fixation in radiotherapy: a feasibility study using original phantom. Phys Med Biol 2017;62:6226-6245. [PMID: 28675378 DOI: 10.1088/1361-6560/aa7d7f] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
47
Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images. Eur J Radiol 2017;93:143-148. [PMID: 28668408 DOI: 10.1016/j.ejrad.2017.05.013] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 05/09/2017] [Accepted: 05/11/2017] [Indexed: 01/27/2023]
48
Kidoh M, Utsunomiya D, Oda S, Nakaura T, Funama Y, Yuki H, Hirata K, Hatemura M, Namimoto T, Yamashita Y. CT venography after knee replacement surgery: comparison of dual-energy CT-based monochromatic imaging and single-energy metal artifact reduction techniques on a 320-row CT scanner. Acta Radiol Open 2017;6:2058460117693463. [PMID: 28321330 PMCID: PMC5347276 DOI: 10.1177/2058460117693463] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Accepted: 01/17/2017] [Indexed: 11/18/2022]  Open
49
Dual energy CT angiography: pros and cons of dual-energy metal artifact reduction algorithm in patients after endovascular aortic repair. Abdom Radiol (NY) 2017;42:749-758. [PMID: 27896386 DOI: 10.1007/s00261-016-0973-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
50
Metal Artifact Reduction on Chest Computed Tomography Examinations. J Comput Assist Tomogr 2017;41:446-454. [DOI: 10.1097/rct.0000000000000544] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
PrevPage 1 of 2 12Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA