1
|
Pesare E, Meschini C, Caredda M, Messina F, Rovere G, Solarino G, Ziranu A. Carbon vs. Titanium Nails in the Treatment of Impending and Pathological Fractures: A Literature Review. J Clin Med 2024; 13:2940. [PMID: 38792483 PMCID: PMC11121808 DOI: 10.3390/jcm13102940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/30/2024] [Accepted: 05/09/2024] [Indexed: 05/26/2024] Open
Abstract
Background: Long bones are commonly affected by musculoskeletal tumors, but they also represent one of the most frequent locations for metastases. The treatment is based on pain management and the prevention or stabilization of pathological fractures by intramedullary nailing. While titanium nails are probably the most used, carbon-fiber-reinforced (CFR) nails have emerged as a new option for oncological patients. The aim of this review is to compare titanium and CFR nails according to current findings. Methods: Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) standards were followed: a total of 1004 articles were identified and 10 were included. Results: Traditionally, titanium implants are highly valued for their optimal biomechanical properties and ease of insertion, facilitated by their radiopacity. However, the use of titanium poses challenges in radiotherapy due to interference with radiation dosage and the creation of ferromagnetic artifacts. Conversely, CFR implants have emerged as a recommended option for intramedullary fixation, due to their biomechanical and structural properties and their benefits during radiotherapy and follow-up monitoring X-ray. Conclusions: CFR nailing represents a promising advancement in the surgical management of oncological patients with long bone metastases. However, further studies are needed to increase surgeons' confidence in their use.
Collapse
Affiliation(s)
- Elisa Pesare
- Orthopaedics Unit, Policlinico Universitario di Bari, Department of Translational Biomedicine and Neuroscience ‘DiBraiN’, University of Bari “Aldo Moro”, Piazza G. Cesare 11, 70124 Bari, Italy;
| | - Cesare Meschini
- Department of Orthopedics Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy (F.M.); (A.Z.)
| | - Matteo Caredda
- Department of Orthopedics Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy (F.M.); (A.Z.)
| | - Federica Messina
- Department of Orthopedics Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy (F.M.); (A.Z.)
| | - Giuseppe Rovere
- Department of Orthopedics Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy (F.M.); (A.Z.)
| | - Giuseppe Solarino
- Orthopaedics Unit, Policlinico Universitario di Bari, Department of Translational Biomedicine and Neuroscience ‘DiBraiN’, University of Bari “Aldo Moro”, Piazza G. Cesare 11, 70124 Bari, Italy;
| | - Antonio Ziranu
- Department of Orthopedics Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy (F.M.); (A.Z.)
- Department of Orthopedics, Ospedale Isola Tiberina-Gemelli Isola, 00186 Rome, Italy
| |
Collapse
|
2
|
Clunk MJ, Gonzalez MR, Denwood HM, Werenski JO, Sodhi A, Hoffman BA, Merchan N, Lozano-Calderon SA. A PEEK into carbon fiber: A practical guide for high performance composite polymeric implants for orthopaedic oncology. J Orthop 2023; 45:13-18. [PMID: 37822644 PMCID: PMC10562613 DOI: 10.1016/j.jor.2023.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 09/25/2023] [Indexed: 10/13/2023] Open
Abstract
Introduction The use of carbon fiber implants in orthopaedic oncology has increased within recent years. The most widely used type of polymer is carbon fiber polyether ether ketone (CF-PEEK). Its radiolucency enables targeted radiotherapy and artifact-free tumor surveillance, which provides major advantages over metallic hardware. We aim to summarize the unique benefits within orthopaedic oncology, clinical pitfalls, and recent advancements. Methods Four representative patient cases from a single tertiary academic medical center were treated with carbon fiber implants (n = 2 nails, n = 2 plates) from 2021 to 2022. Results There were no adverse events noted during intraoperative implantation or postoperative follow up. All patients reported improvements in pain and no difficulties in ambulation. There were no instances of catastrophic failure or implant loosening. Conclusion CF implants offer a diverse array of advantages regarding its radiolucency, low scatter density, and bioinert profile. Nonetheless, further research is required to understand the long-term surgical outcomes and robustness of CF implants. Multi institutional trials could address important aspects of durability and stability over extended periods, feasibility and ease-of-use for different anatomical sites and bone quality, as well as cost-effectiveness in post-operative imaging, healthcare resource utilization, and revision rates. Providing orthopaedic surgeons with valuable insight will enable thorough clinically supported, informed decision making regarding optimal use of implants.
Collapse
Affiliation(s)
- Marilee J. Clunk
- Musculoskeletal Oncology Service, Department of Orthopaedic Surgery, Massachusetts General Hospital Boston, MA, 02114, USA
- University of Toledo College of Medicine and Life Sciences Toledo, OH, 43614, USA
| | - Marcos R. Gonzalez
- Musculoskeletal Oncology Service, Department of Orthopaedic Surgery, Massachusetts General Hospital Boston, MA, 02114, USA
| | - Hayley M. Denwood
- Musculoskeletal Oncology Service, Department of Orthopaedic Surgery, Massachusetts General Hospital Boston, MA, 02114, USA
- Boston University Chobanian and Avedisian School of Medicine Boston, MA, 02118, USA
| | - Joseph O. Werenski
- Musculoskeletal Oncology Service, Department of Orthopaedic Surgery, Massachusetts General Hospital Boston, MA, 02114, USA
| | - Alisha Sodhi
- Musculoskeletal Oncology Service, Department of Orthopaedic Surgery, Massachusetts General Hospital Boston, MA, 02114, USA
| | - Brett A. Hoffman
- University of Toledo College of Medicine and Life Sciences Toledo, OH, 43614, USA
| | - Nelson Merchan
- Musculoskeletal Oncology Service, Department of Orthopaedic Surgery, Massachusetts General Hospital Boston, MA, 02114, USA
| | - Santiago A. Lozano-Calderon
- Musculoskeletal Oncology Service, Department of Orthopaedic Surgery, Massachusetts General Hospital Boston, MA, 02114, USA
| |
Collapse
|
3
|
Synergistic effect of sulfonation followed by precipitation of amorphous calcium phosphate on the bone-bonding strength of carbon fiber reinforced polyetheretherketone. Sci Rep 2023; 13:1443. [PMID: 36697480 PMCID: PMC9876887 DOI: 10.1038/s41598-023-28701-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 01/23/2023] [Indexed: 01/26/2023] Open
Abstract
Sulfonation and applications of amorphous calcium phosphate are known to make polyetheretherketone (PEEK) bioactive. Sulfonation followed by precipitation of amorphous calcium phosphate (AN-treatment) may provide PEEK with further bone-bonding strength. Herein, we prepared a carbon-fiber-reinforced PEEK (CPEEK) with similar tensile strength to cortical bone and a CPEEK subjected to AN-treatment (CPEEK-AN). The effect of AN-treatment on the bone-bonding strength generated at the interface between the rabbit's tibia and a base material was investigated using a detaching test at two time-points (4 and 8 weeks). At 4 weeks, the strength of CPEEK-AN was significantly higher than that of CPEEK due to the direct bonding between the interfaces. Between 4 and 8 weeks, the different bone forming processes showed that, with CPEEK-AN, bone consolidation was achieved, thus improving bone-bonding strength. In contrast, with CPEEK, a new bone was absorbed mainly on the interface, leading to poor strength. These observations were supported by an in vitro study, which showed that pre-osteoblast on CPEEK-AN caused earlier maturation and mineralization of the extracellular matrix than on CPEEK. Consequently, AN-treatment, comprising a combination of two efficient treatments, generated a synergetic effect on the bonding strength of CPEEK.
Collapse
|
4
|
Lowen GB, Garrett KA, Moore-Lotridge SN, Uppuganti S, Guelcher SA, Schoenecker JG, Nyman JS. Effect of Intramedullary Nailing Patterns on Interfragmentary Strain in a Mouse Femur Fracture: A Parametric Finite Element Analysis. J Biomech Eng 2022; 144:051007. [PMID: 34802060 PMCID: PMC8822464 DOI: 10.1115/1.4053085] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 11/17/2021] [Indexed: 11/08/2022]
Abstract
Delayed long bone fracture healing and nonunion continue to be a significant socioeconomic burden. While mechanical stimulation is known to be an important determinant of the bone repair process, understanding how the magnitude, mode, and commencement of interfragmentary strain (IFS) affect fracture healing can guide new therapeutic strategies to prevent delayed healing or nonunion. Mouse models provide a means to investigate the molecular and cellular aspects of fracture repair, yet there is only one commercially available, clinically-relevant, locking intramedullary nail (IMN) currently available for studying long bone fractures in rodents. Having access to alternative IMNs would allow a variety of mechanical environments at the fracture site to be evaluated, and the purpose of this proof-of-concept finite element analysis study is to identify which IMN design parameters have the largest impact on IFS in a murine transverse femoral osteotomy model. Using the dimensions of the clinically relevant IMN as a guide, the nail material, distance between interlocking screws, and clearance between the nail and endosteal surface were varied between simulations. Of these parameters, changing the nail material from stainless steel (SS) to polyetheretherketone (PEEK) had the largest impact on IFS. Reducing the distance between the proximal and distal interlocking screws substantially affected IFS only when nail modulus was low. Therefore, IMNs with low modulus (e.g., PEEK) can be used alongside commercially available SS nails to investigate the effect of initial IFS or stability on fracture healing with respect to different biological conditions of repair in rodents.
Collapse
Affiliation(s)
- Gregory B. Lowen
- Vanderbilt University, Department of Chemical and Biomolecular Engineering, 2201 West End Ave, Nashville, TN 37235
| | - Katherine A. Garrett
- Vanderbilt University Medical Center, Department of Orthopaedic Surgery, 1215 21 Ave. S., Suite 4200, Nashville, TN 37232
| | - Stephanie N. Moore-Lotridge
- Vanderbilt University Medical Center, Department of Orthopaedic Surgery, 1215 21 Ave. S., Suite 4200, Nashville, TN 37232;Vanderbilt University Medical Center, Vanderbilt Center for Bone Biology, 1211 Medical Center Dr., Nashville, TN 37212
| | - Sasidhar Uppuganti
- Vanderbilt University Medical Center, Department of Orthopaedic Surgery, 1215 21 Ave. S., Suite 4200, Nashville, TN 37232;Vanderbilt University Medical Center, Vanderbilt Center for Bone Biology, 1211 Medical Center Dr., Nashville, TN 37212
| | - Scott A. Guelcher
- Vanderbilt University, Department of Chemical and Biomolecular Engineering, 2201 West End Ave, Nashville, TN 37235; Vanderbilt University, Department of Biomedical Engineering, 5824 Stevenson Center, Nashville, TN 37232; Vanderbilt University Medical Center, Vanderbilt Center for Bone Biology, 1211 Medical Center Dr., Nashville, TN 37212; Vanderbilt University Medical Center, Division of Clinical Pharmacology, 1211 Medical Center Dr, Nashville, TN 37217
| | - Jonathan G. Schoenecker
- Vanderbilt University, Department of Pharmacology, 465 21 Ave South, 7124 Medical Research Building III, Nashville, TN 37232; Vanderbilt University Medical Center, Vanderbilt Center for Bone Biology, 1211 Medical Center Dr., Nashville, TN 37212; Vanderbilt University Medical Center, Department of Pathology, Microbiology, and Immunology, 1161 21 Ave S C-3322 Medical Center North, Nashville, TN 37232; Vanderbilt University Medical Center, Department of Pediatrics, 2200 Children's Way, Suite 2404, Nashville, TN 37232
| | - Jeffry S. Nyman
- Vanderbilt University, Department of Biomedical Engineering, 5824 Stevenson Center, Nashville, TN 37232; Vanderbilt University Medical Center, Department of Orthopaedic Surgery, 1215 21 Ave. S., Suite 4200, Nashville, TN 37232; Vanderbilt University Medical Center, Vanderbilt Center for Bone Biology, 1211 Medical Center Dr., Nashville, TN 37212; Tennessee Valley Healthcare System, Department of Veterans Affairs, 1310 24 Ave. S, Nashville, TN 37212
| |
Collapse
|
5
|
Guo Y, Guo W. Study and numerical analysis of Von Mises stress of a new tumor-type distal femoral prosthesis comprising a peek composite reinforced with carbon fibers: finite element analysis. Comput Methods Biomech Biomed Engin 2022; 25:1663-1677. [PMID: 35094629 DOI: 10.1080/10255842.2022.2032681] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Research on carbon-fiber-reinforced polyetheretherketone (CF-PEEK/CFR-PEEK) as a bone tumor joint prosthesis remains limited. Herein we numerically determine the feasibility of CF-PEEK material containing 30% Wt carbon fiber (CF30-PEEK) as a material for the dual-action tumor-type distal femoral prosthesis. Use CT scan method to build a complete finite element model of the knee joint. Simulate the resection of the distal femoral tumor, and then reconstruct it with the dual-action tumor-type distal femoral prosthesis. The femoral condyle and extension rod components were simulated with cobalt chromium molybdenum (CoCrMo), PEEK and CF30-PEEK materials respectively. When simulating the standing state, a vertical stress of 700 N is applied to the femoral head. When simulating the squatting state, a vertical stress of 2800 N is applied to the femoral head. The displacement and rotation angle of each node of the distal tibia are fully restrained in three directions (X-axis, Y-axis, Z-axis). We examined the stress magnitude, stress distribution, and stability of the prosthesis and each of its components by means of finite element analysis (FE analysis). The FE analysis results show: after replacing the distal femur and the extension rod with CF30-PEEK material, the stress is still evenly distributed, and the average stress is significantly reduced. In addition, the stability is similar to CoCrMo material. Therefore, CF30-PEEK is an appropriate material for this type of prosthesis.
Collapse
Affiliation(s)
- Yu Guo
- Musculoskeletal Tumor Center, Peking University People's Hospital, Beijing, People's Republic of China.,Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China
| | - Wei Guo
- Musculoskeletal Tumor Center, Peking University People's Hospital, Beijing, People's Republic of China.,Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China
| |
Collapse
|
6
|
|