1
|
Gerber S, Kwong GP, Ho J. Assessment of insulin dose changes in pediatric patients with type 1 diabetes mellitus starting on continuous subcutaneous insulin infusion. J Clin Transl Endocrinol 2024; 37:100363. [PMID: 39161664 PMCID: PMC11332060 DOI: 10.1016/j.jcte.2024.100363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 06/18/2024] [Accepted: 07/19/2024] [Indexed: 08/21/2024] Open
Abstract
Objective To assess change in total daily dose (TDD) of insulin following a switch from subcutaneous (SC) injections to continuous subcutaneous insulin infusion (CSII) in pediatric patients with type 1 diabetes (T1D). Secondary objectives were to determine the change in %basal insulin, insulin to carbohydrate (I:C) ratios, insulin sensitivity factor (ISF), and HbA1c/IDAA1c. Methods A retrospective chart review of patients < 18 years of age who transitioned from SC to CSII at the Alberta Children's Hospital (Calgary, Alberta, Canada) between January 2019 and March 2022. Results There was an increase of 0.04 units/kg/day in TDD from baseline vs 1-3 months later (p = 0.04, 95 % confidence interval (CI) [0.002, 0.072]). When stratified by age, a similar increase in TDD was observed in age 5-12 years only (p = 0.05, 95 % CI [0.0006, 0.8236]). There was a decrease in overall %basal insulin by 3 (44 % of TDD at baseline vs 41 % of TDD on CSII). (p = 0.02, 95 % CI [-5.5, -0.4]). No strengthening was seen in I:C ratios from baseline vs 1-3 months later. There was a significant strengthening of I:C ratios at all meals in the basal bolus group from 1-3 weeks to 1-3 months post-CSII; overall strengthening of ISF at both time points; and an overall HbA1c decrease -0.30 (p < 0.0001, CI [-0.45, -0.15]). Each extra year with diabetes was associated with a decrease in HbA1c by 0.07 % (p = 0.006). Conclusions TDD of insulin was not found to be decreased post CSII initiation and patient characteristics should be considered when changing from SC to CSII. HbA1c was significantly improved post CSII.
Collapse
Affiliation(s)
- Samantha Gerber
- Department of Pediatrics, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Grace P.S. Kwong
- Alberta Children’s Hospital Research Institute and Department of Community Health Sciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Josephine Ho
- Department of Pediatrics, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| |
Collapse
|
2
|
Bağ Ö, Tunç S, Nalbantoğlu Ö, Ecevit Ç, Öztürk A, Özkan B, Demir K. Higher-Than-Conventional Subcutaneous Regular Insulin Doses Following Diabetic Ketoacidosis in Children and Adolescents. J Clin Res Pediatr Endocrinol 2017; 9:132-137. [PMID: 28044993 PMCID: PMC5463285 DOI: 10.4274/jcrpe.3925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
OBJECTIVE To evaluate the effect of initial insulin dosage on glycemic control in the first 48 hours of subcutaneous regular insulin therapy after resolution of diabetic ketoacidosis (DKA). METHODS Records of patients with DKA hospitalized in the past 3 years [n=76, median age=10.0 (6.0-12.0) years, Male/Female: 44/32] were reviewed. The patients were designated into two groups according to distribution of starting doses of subcutaneous insulin. Group 1 (n=28) received a median dose of 1.45 U/kg/day (1.41-1.5) and group 2 (n=48) a median dose of 0.96 U/kg/day (0.89-1). Clinical and laboratory data were analyzed. RESULTS Median, minimum, and maximum blood glucose levels of Group 1 in the first 48 hours of treatment were significantly lower than that of Group 2 [213 (171-242) vs. 255 (222-316), p=<0.001; 102 (85-151) vs. 129 (105-199), p=0.004; and 335 (290-365) vs. 375 (341-438), p=0.001, respectively]. The number of patients who experienced hypoglycemia (<70 mg/dL) were similar [Group 1, 5 (17.9%) vs. Group 2, 4 (8.3%), p=0.276] and none had severe hypoglycemia. In Group 1, the ratio of blood glucose levels within the target range (100-200 mg/dL) were higher (37.5% vs. 12.5%) and the number of results >200 mg/dL were lower (50% vs. 81.3%) compared to Group 2 (p=0.001 and p<0.001, respectively). CONCLUSION After resolution of DKA, a higher initial dose of 1.4-1.5 U/kg/day regular insulin is associated with better glycemic control in children and adolescents without an increase in risk of hypoglycemia.
Collapse
Affiliation(s)
- Özlem Bağ
- Dr. Behçet Uz Children's Hospital, Clinic of Pediatrics, İzmir, Turkey, Phone: +90 232 464 6167 E-mail:
| | - Selma Tunç
- Dr. Behçet Uz Children’s Hospital, Clinic of Pediatric Endocrinology, İzmir, Turkey
| | - Özlem Nalbantoğlu
- Dr. Behçet Uz Children’s Hospital, Clinic of Pediatric Endocrinology, İzmir, Turkey
| | - Çiğdem Ecevit
- Dr. Behçet Uz Children’s Hospital, Clinic of Pediatrics, İzmir, Turkey
| | - Aysel Öztürk
- Dr. Behçet Uz Children’s Hospital, Clinic of Pediatrics, İzmir, Turkey
| | - Behzat Özkan
- Dr. Behçet Uz Children’s Hospital, Clinic of Pediatric Endocrinology, İzmir, Turkey
| | - Korcan Demir
- Dokuz Eylül University Faculty of Medicine, Department of Pediatrics, Division of Pediatric Endocrinology, İzmir, Turkey
| |
Collapse
|
3
|
Deeb A, Abu-Awad S, Abood S, El-Abiary M, Al-Jubeh J, Yousef H, AbdelRahman L, Al Hajeri A, Mustafa H. Important determinants of diabetes control in insulin pump therapy in patients with type 1 diabetes mellitus. Diabetes Technol Ther 2015; 17:166-70. [PMID: 25513744 DOI: 10.1089/dia.2014.0224] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
BACKGROUND Insulin pumps are equipped with advanced functions. Intensive training and adherence are required for optimum use of the technology. We aimed to assess the association of various key elements in insulin pump functions on blood glucose control. PATIENTS AND METHODS Patients on insulin pump therapy were enrolled. Insulin pumps were downloaded (CareLink(®) Pro 3 software; Medtronic Minimed, Northridge, CA), and data were collected over an 8-12-week period. Glycemic control of patients was classified as controlled (hemoglobin A1c [HbA1c] level of 7.5% or less in adults and 8% or less in children) and uncontrolled based on HbA1c level at enrollment. Variables studied were use of sensors and duration, frequency of blood glucose monitoring, Bolus Wizard (Medtronic Minimed) use, frequency of correction boluses, and frequency of cannula changing. RESULTS Seventy-two patients were enrolled (50 children). Median age was 12 years for children and 27.5 years for adults. Respective median numbers of blood glucose checks were 4.4 and 3.2 for controlled and uncontrolled children (P<0.021) and 3.1 and 2.8 for controlled and uncontrolled adults, respectively. Respective frequency of Bolus Wizard use per day showed a median of 6 and 4.15 for controlled and uncontrolled children (P<0.001) and 3.8 and 3.5 for controlled and uncontrolled adults. Controlled children wore sensors for longer (5 vs. 2.9 days/week) and did more corrections (3.9 vs. 2.5). There was no difference in the frequency of changing the infusion cannula in children's or adults' groups. CONCLUSIONS We conclude that the frequency of blood glucose monitoring and Bolus Wizard use have a favorable association with glycemic control. These observations were more significant in the children's groups. Our data shows that patients with better control tend to bolus more for correction and wear sensors longer.
Collapse
Affiliation(s)
- Asma Deeb
- 1 Paediatric Endocrinology Department, Mafraq Hospital , AbuDhabi, United Arab Emirates
| | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Adams GG, Imran S, Wang S, Mohammad A, Kok MS, Gray DA, Channell GA, Harding SE. The hypoglycemic effect of pumpkin seeds, Trigonelline (TRG), Nicotinic acid (NA), and D-Chiro-inositol (DCI) in controlling glycemic levels in diabetes mellitus. Crit Rev Food Sci Nutr 2014; 54:1322-9. [PMID: 24564589 DOI: 10.1080/10408398.2011.635816] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
In the contemporary society, diabetes mellitus is considered as a common, growing, serious, costly, and potentially preventable public health problem. It is forecasted that in 2030, the number of people with diabetes will go up from 117 million in 2000 to 366 million in 2030. The prevalence of diabetes will place a huge burden on health and financial structures of countries, and these will impact on individuals, as well as families and nations. Polysaccharides, para-aminobenzoic acid, fixed oils, sterol, proteins, and peptides are biologically active ingredients, which are found in pumpkins. The chemicals within pumpkins such as the fruit pulp, oil from ungerminated seeds, and protein from germinated seeds have hypoglycemic properties. Preliminary investigation showed that pumpkin seeds, and the macromolecules, therein, such as Trigonelline (TRG), Nicotinic acid (NA), and D-chiro-inositol (DCI), possess hypoglycemic properties and could assist in maintaining glycemic control.
Collapse
Affiliation(s)
- Gary G Adams
- a Faculty of Medicine and Health Sciences, Queen's Medical Centre , University of Nottingham , Clifton Boulevard , Nottingham , NG7 2RD , UK
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Skjaervold NK, Aadahl P. Comparison of arterial and mixed venous blood glucose levels in hemodynamically unstable pigs: implications for location of a continuous glucose sensor. Acta Diabetol 2012; 49:489-91. [PMID: 22527096 DOI: 10.1007/s00592-012-0394-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2012] [Accepted: 04/01/2012] [Indexed: 10/28/2022]
Abstract
One of several unsolved challenges in the construction of an artificial endocrine pancreas (a system for automatically adjusting the blood glucose level) is the positioning of the glucose sensor. We believe the best positioning to be either intraarterial or in a central vein. It is therefore important to know whether the glucose content in these blood locations is the same. We conducted a post hoc analysis of previously collected data from pigs exposed to gross inflammatory and circulatory stress. Paired arterial and mixed venous glucose values were compared with a mixed effects model. We found the blood glucose values from the arterial and mixed venous blood to be the same.
Collapse
Affiliation(s)
- Nils K Skjaervold
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway.
| | | |
Collapse
|
6
|
Lombardo F, Scaramuzza AE, Iafusco D. Failure of glycated hemoglobin drop after continuous subcutaneous insulin infusion initiation may indicate patients who discontinue: a 4-year follow-up study in children and adolescents with type 1 diabetes. Acta Diabetol 2012; 49 Suppl 1:S99-105. [PMID: 22008950 DOI: 10.1007/s00592-011-0344-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2011] [Accepted: 10/05/2011] [Indexed: 01/09/2023]
Abstract
Continuous subcutaneous insulin infusion (CSII) is effective and safe in children and adults with type 1 diabetes. Notwithstanding, some patients decide to discontinue using CSII. We evaluated the discontinuation rate, and its related factors, in a large group of children and adolescents with type 1 diabetes using CSII in Italy. Data on all patients with type 1 diabetes younger than 18 years were collected by 28 Pediatric Diabetologic referral Centers located throughout Italy. The primary endpoint was to measure the discontinuation rate using CSII. Among the study population (n = 6,644), 985 (14.8%) were using CSII. Sixty patients discontinued using CSII, representing the 6.1%. The discontinuation rate significantly increased (P = 0.002) with age: 0-6 years, 1/84 (1.2%), 7-11 years, 8/262 (3.1%), 12-18 years, 51/579 (8.8%). The average time to discontinuation was 1.8 ± 1.4 years. The average age of patients who discontinued using CSII was higher than in patients still on CSII (12.1 ± 3.2 vs. 10.3 ± 3.8, P = 0.0001), while their diabetes duration was significantly shorter (8.6 ± 2.7 vs. 10.2 ± 3.7, P = 0.0001). HbA1c decreased only in patients still on CSII (8.7 ± 1.3% vs. 7.8 ± 1.3%, P = 0.02), but not in patients who discontinued using CSII (8.5 ± 1.6% vs. 8.2 ± 1.3%, P = 0.213). HbA1c might be one important indicator helpful to identify patients at higher risk discontinuing using CSII.
Collapse
Affiliation(s)
- Fortunato Lombardo
- Department of Pediatric Sciences, University of Messina, 98123 Messina, Italy
| | | | | |
Collapse
|
7
|
Soggiu A, Piras C, Bonizzi L, Hussein HA, Pisanu S, Roncada P. A discovery-phase urine proteomics investigation in type 1 diabetes. Acta Diabetol 2012; 49:453-64. [PMID: 22678621 DOI: 10.1007/s00592-012-0407-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Accepted: 05/22/2012] [Indexed: 01/15/2023]
Abstract
Diabetes is a chronic metabolic disease which can lead to serious health problems particularly in and to the development of cardiovascular and renal complications. The aim of this study is to possibly identify distinctive molecular features in urine samples which might correlate to the progression and complications of type 1 diabetes. Diabetic patients with normo- and micro-albuminuria have been analyzed and compared to a group of control subjects. Urine proteins of control and type 1 diabetes subjects were investigated in their proteome profiles, using high-resolution two-dimensional gel electrophoresis separation and protein identifications by MALDI-TOF-MS and LC-MS/MS analysis. Proteomics analysis highlighted differential expression of several proteins between control and type 1 diabetes subjects. In particular, five proteins were found to be down-regulated and four proteins up-regulated. Lower protein representations in diabetic subjects were associated with Tamm-Horsfall urinary glycoprotein, apolipoprotein A-I, apolipoprotein E, α2-thiol proteinase inhibitor, and human complement regulatory protein CD59, while higher protein representations were found for α-1-microglobulin, zinc-α2 glycoprotein, α-1B glycoprotein, and retinol-binding protein 4. These differences were maintained comparing control subjects with type 1 diabetes normo-albuminuric and micro-albuminuric subjects. Furthermore, these proteins are correlated to glycosylated hemoglobin and microalbuminuria, confirming their role in diabetic pathology. This study gives new insights on potential molecular mechanisms associated with the complications of type 1 diabetic disease providing evidences of urine proteins potentially exploitable as putative prognostic biomarkers.
Collapse
Affiliation(s)
- A Soggiu
- Dipartimento di Patologia Animale, Igiene e Sanità Pubblica Veterinaria, Facoltà di Medicina Veterinaria, Università Degli Studi di Milano, Milan, Italy
| | | | | | | | | | | |
Collapse
|
8
|
Fendler W, Baranowska AI, Mianowska B, Szadkowska A, Mlynarski W. Three-year comparison of subcutaneous insulin pump treatment with multi-daily injections on HbA1c, its variability and hospital burden of children with type 1 diabetes. Acta Diabetol 2012; 49:363-70. [PMID: 21964866 PMCID: PMC3464376 DOI: 10.1007/s00592-011-0332-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2011] [Accepted: 09/14/2011] [Indexed: 11/02/2022]
Abstract
Treatment with continuous subcutaneous insulin infusion (CSII) allows a large degree of treatment individualization and intensification in children with diabetes. The study's aim was to evaluate the impact of treatment with CSII on glycated haemoglobin level (HbA1c) in children with diabetes and investigate whether introduction of CSII is associated with an increased risk of acute complications of diabetes. Patients treated throughout the recruitment period exclusively with multiple daily injections (MDI) were matched for duration of diabetes and HbA1c level at baseline with patients treated exclusively with CSII in a 1:1 group ratio (n = 223 and 231 for MDI and CSII, respectively). The CSII group showed lower HbA1c after the observation period (7.98 ± 1.38 vs. 7.56 ± 0.97; P = 0.002). HbA1c variability measured as standard deviations of average values was also lower in the CSII group (0.73 ± 0.45 vs. 0.84 ± 0.54; P = 0.049). The rate of hospitalization due to acute events was similar in both groups (14.7/100 vs. 14.0/100 person/years in the MDI and CSII group, P = 0.72). Duration of hospital stay per year was on average 1.25 days shorter in the CSII group (P = 0.0004), but the risk of acute complications resulting in hospitalization did not differ between the groups (hazard ratio (HR) 1.16; 95% confidence interval (95% CI) 0.68-1.63). The most significant risk factor for hospitalization due to acute complications was baseline HbA1c concentration (HR 1.25; 95% CI 1.14-1.37). In conclusion, CSII treatment may improve glycemic control and reduce its variability. Change of MDI to CSII does not alter the risk of hospitalization and may reduce the annual duration of hospitalization in children with diabetes.
Collapse
Affiliation(s)
- Wojciech Fendler
- Department of Paediatrics, Oncology, Haematology and Diabetology, Medical University of Lodz, 36/50 Sporna St., 91-738 Lodz, Poland
| | - Anna Iza Baranowska
- Department of Paediatrics, Oncology, Haematology and Diabetology, Medical University of Lodz, 36/50 Sporna St., 91-738 Lodz, Poland
| | - Beata Mianowska
- Department of Paediatrics, Oncology, Haematology and Diabetology, Medical University of Lodz, 36/50 Sporna St., 91-738 Lodz, Poland
| | - Agnieszka Szadkowska
- Department of Paediatrics, Oncology, Haematology and Diabetology, Medical University of Lodz, 36/50 Sporna St., 91-738 Lodz, Poland
| | - Wojciech Mlynarski
- Department of Paediatrics, Oncology, Haematology and Diabetology, Medical University of Lodz, 36/50 Sporna St., 91-738 Lodz, Poland
| |
Collapse
|
9
|
Chlup R, Doubravova B, Peterson K, Zapletalova J, Bartek J. Wavesense technology glucometer Linus for routine self-monitoring and clinical practice. Acta Diabetol 2011; 48:35-40. [PMID: 20694824 DOI: 10.1007/s00592-010-0213-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2010] [Accepted: 07/26/2010] [Indexed: 11/28/2022]
Abstract
Conventional glucometer systems for plasma/blood glucose monitoring are based on colorimetry or static electrochemistry using a fixed input signal. The recent glucometer Linus, Wellion, Agamatrix, USA, based on wavesense dynamic electrochemistry, uses a time-varying input signal to give a more accurate glucose reading. The purpose of this study was to compare the plasma glucose (PG) readings obtained by nursing staff from glucometer Linus and PG values estimated on an approved analyzer Daytona™, Randox, Global Medical Instrumentation, Inc., MN, USA. In the course of 5 weeks, 221 fingerprick capillary blood samples were taken from persons with diabetes at different times and investigated using glucometer Linus. Within two following minutes, blood from the same fingerprick was also collected in a tube and centrifuged; the plasma was analyzed on the Daytona™ analyzer. Statistical analysis was performed using the software SPSS v. 15.0, SPSS Inc., Chicago, IL, USA. A total of 221 paired PG values were plotted on the error grid diagram indicating that 218 values (98.6%) of the glucose readings (Linus vs. Daytona) were within the clinically accurate zone A (maximum difference ±20%) and 3 values (1.4%) within the acceptable zone B. Daytona showed 4 PG values <4.2 mmol/l (75 mg/dl) and their difference of respective Linus readings was always <0.83 mmol/l (15 mg/dl). Correlation of results was strong (r = 0.992). Glucometer Linus readings correspond to the ISO and FDA standards. So, Linus appears to be an accurate device for PG-self-monitoring and clinical practice.
Collapse
Affiliation(s)
- Rudolf Chlup
- Department of Physiology, Faculty of Medicine, Palacký University, Hnevotinska 3, Olomouc, Czech Republic.
| | | | | | | | | |
Collapse
|
10
|
Monami M, Lamanna C, Marchionni N, Mannucci E. Continuous subcutaneous insulin infusion versus multiple daily insulin injections in type 1 diabetes: a meta-analysis. Acta Diabetol 2010; 47 Suppl 1:77-81. [PMID: 19504039 DOI: 10.1007/s00592-009-0132-5] [Citation(s) in RCA: 78] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2009] [Accepted: 05/12/2009] [Indexed: 11/26/2022]
Abstract
Continuous subcutaneous insulin infusion (CSII) is considered an option for type 1 diabetic patients unsatisfactorily controlled with multiple daily injections (MDI). Short-acting analogs are superior to regular human insulin in CSII. This meta-analysis is aimed at assessing the advantages of short-acting analog-based CSII over MDI in type 1 diabetes. Randomized clinical trials (RCTs) comparing CSII (with analogs) and MDI for at least 12 weeks in type 1 diabetic patients were retrieved, assessing between-group differences in HbA1c and incidence of hypoglycemia. A total of 11 RCTs was included in the analysis. CSII was associated with a significant improvement of HbA1c in comparison with MDI (standardized difference in mean: -0.3 [-0.4;-0.1]%; P < 0.001). No significant difference was observed in the rate of severe hypoglycemic episodes. The reduction of HbA1c with CSII was evident in trials enrolling patients with mean age greater than 10 years, but not in younger children. Available data justify the use of CSII for basal-bolus insulin therapy in type 1 diabetic patients unsatisfactorily controlled with MDI.
Collapse
Affiliation(s)
- Matteo Monami
- Section of Geriatric Cardiology, Department of Cardiovascular Medicine, Azienda Ospedaliero-Universitaria Careggi, Via delle Oblate 4, 50141 Florence, Italy.
| | | | | | | |
Collapse
|