1
|
Wan GZ, Liu J, Chen J. Immobilization of α-Glucosidase on Polyethylene Glycol Diglycidyl Ether-Modified NH 2-MIL-53(Al) for Inhibitory Activity Assay of Traditional Chinese Medicine. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2025; 41:4355-4368. [PMID: 39924890 DOI: 10.1021/acs.langmuir.4c05114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/11/2025]
Abstract
Enzyme inhibition-based drug screening is a critical strategy in drug development. However, significant limitations arise from the instability, limited reusability, and narrow applicability of traditional enzyme assays when screening for inhibitors in complex matrices, such as extracts of traditional Chinese medicines (TCMs). A screening strategy was developed that combines capillary electrophoresis (CE) with an enzymatic assay utilizing covalently immobilized α-glucosidase (α-Glu). NH2-MIL-53(Al) was synthesized using a hydrothermal method, serving as a robust support for enzyme immobilization. By employing polyethylene glycol diglycidyl ether (PEGDGE) as a covalent linker, significant enhancements in the stability and reusability of α-Glu were achieved. The immobilized enzyme maintained 77.7% of its initial activity over 10 cycles and displayed a Michaelis-Menten constant of 1.25 mM. Moreover, the inhibition constant and IC50 values for acarbose were determined to be 17.41 μM and 0.46 μM, respectively. Utilizing this immobilized enzyme system, screening of 12 TCMs identified several potent α-Glu inhibitors, including Chebulae Fructus and Curcumae Longae Rhizoma. These results highlight the successful integration of NH2-MIL-53(Al) and PEGDGE in creating a stable and reusable screening platform for enzyme inhibitors. This approach not only advances the field of enzyme immobilization technology but also provides a promising pathway for discovering antidiabetic agents from natural sources.
Collapse
Affiliation(s)
- Guang-Zhen Wan
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Jia Liu
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| | - Juan Chen
- School of Pharmacy, Lanzhou University, Lanzhou 730000, China
| |
Collapse
|
2
|
Wu Y, Jiang N, He Z, Yang Y, Li Y. Direct electrochemical detection of extracellular nitric oxide in Arabidopsis protoplast based on cytochrome P450 55B1 biosensor. Nitric Oxide 2023; 132:8-14. [PMID: 36731643 DOI: 10.1016/j.niox.2023.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 12/05/2022] [Accepted: 01/24/2023] [Indexed: 02/01/2023]
Abstract
Cytochrome P450 55B1(CYP55B1) from Chlamydomonas reinhardtii reduces nitric oxide (NO) to dinitrogen oxide (N2O) with the electron supply from NAD(P)H in vivo. Here a novel nitric oxide biosensor was developed by immobilized CYP55B1 on the surface of pyrolytic graphite electrode (PGE) by cross-linking with glutaraldehyde (GA) and bovine serum albumin (BSA). The direct electrochemistry of CYP55B1 was realized with the redox peak potential of -0.355 V and -0.385 V and the catalytic reduction peak of NO by CYP55B1 is at -0.85 V at the scan rate of 0.5 V S-1 in pH 7.0 phosphate buffer. The apparent coverage (Γ = 1.43 × 10-11 mol cm-2), the electron transfer rate constant (ks = 17.39 s-1) and apparent affinity to NO (Kmapp = 11.64 nM) of CYP55B1 in GA/BSA film were obtained. The catalytic mechanism of CYP55B1 towards NO with NADH was examined by the biosensor. The linear range of NO detection was investigated by differential pulse voltammetry with the results of 5-50 nM and the detection limit of 0.5 nM (S/N = 3). The selectivity and stability of the electrochemical biosensor were investigated. Furthermore, the CYP55B1electrochemical biosensor was applied to monitor NO release from Arabidopsis protoplasts with the average content of 0.848 fmol per cell under anaerobic condition.
Collapse
Affiliation(s)
- Yunhua Wu
- College of Life Science, South-Central Minzu University, 430074, China.
| | - Nan Jiang
- College of Life Science, South-Central Minzu University, 430074, China
| | - Zheng He
- College of Life Science, South-Central Minzu University, 430074, China
| | - Yong Yang
- State Key Laboratory of Biocatalysis and Enzyme Engineering, School of Life Sciences, Hubei University, 430062, China
| | - Yong Li
- College of Life Science, South-Central Minzu University, 430074, China.
| |
Collapse
|
3
|
Guo J, Wei T, Huang Q, Li M, Yang C, Mou J, Shi L, Gao T, Li G. Direct acupuncture of nitric oxide by an electrochemical microsensor with high time-space resolution. Biosens Bioelectron 2022; 195:113667. [PMID: 34598107 DOI: 10.1016/j.bios.2021.113667] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 09/16/2021] [Accepted: 09/21/2021] [Indexed: 11/28/2022]
Abstract
Measurement of signal molecule is critically important for understanding living systems. Nitric oxide (NO) is a key redox signal molecule that shows diverse roles in virtually all life forms. However, probing into NO's activities is challenging as NO has restricted lifetime (<10 s) and limited diffusion distance (usually <200 μm). So, for the direct acupuncture of NO within the time-space resolution, an electrochemical microsensor has been designed and fabricated in this work. Fabrication of the microsensor is achieved by (1) selective assembly of an electrocatalytic transducer, (2) attaching the transducer on carbon fiber electrode, and (3) covered it with a screen layer to reduce signal interference. The fabricated microsensor exhibits high sensitivity (LOD, 13.5 pM), wide detection range (100 pM-5 μM), and good selectivity. Moreover, studies have revealed that the availability of the sensor for efficient detection of NO is due to the formation of a specific DNA/porphyrin hybrid structure that has synergetic effects on NO electrocatalysis. Therefore, NO release by cells and tissues can be directly and precisely traced, in which we have obtained the release pattern of NO by different cancer cell lines, and have known its dynamics in tumor microenvironment. The fabricated electrocatalytic microsensor may provide a unique and useful tool for the direct assay of NO with high time-space resolution, which promisingly gives a technical solution for the bioassay of NO in living systems.
Collapse
Affiliation(s)
- Jiarong Guo
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Tianxiang Wei
- School of Environment, Nanjing Normal University, Nanjing, 210023, China
| | - Qiongbo Huang
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Mingyue Li
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Cui Yang
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Junhui Mou
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Liu Shi
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, China
| | - Tao Gao
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China.
| | - Genxi Li
- State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, China; Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, 200444, China.
| |
Collapse
|
4
|
Kim DH, Han JH, Kwon HC, Lim SJ, Han SG, Jung HS, Lee KH, Kang JH, Han SG. Toxicity Assessment of a Single Dose of Poly(ethylene glycol) Diglycidyl Ether (PEGDE) Administered Subcutaneously in Mice. TOXICS 2021; 9:toxics9120354. [PMID: 34941788 PMCID: PMC8708792 DOI: 10.3390/toxics9120354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/08/2021] [Accepted: 12/12/2021] [Indexed: 11/16/2022]
Abstract
Poly(ethylene glycol) diglycidyl ether (PEGDE) is widely used to cross-link polymers, particularly in the pharmaceutical and biomaterial sectors. However, the subcutaneous toxicity of PEGDE has not yet been assessed. PEGDE samples (500–40,000 μg/mouse) were subcutaneously injected into the paraspinal dorsum of BALB/c male mice. Cage-side observations were carried out with measurement of organ weight, body weight variation, and feed intake, as well as histopathological characterization on day 28 post-exposure. Mice that received 40,000 μg of PEGDE showed severe toxic response and had to be euthanized. Subcutaneous injection of PEGDE did not alter feed intake and organ weight; however, the body weight variation of mice injected with 20,000 μg of PEGDE was significantly lower than that of the other groups. Exposure to 10,000 and 20,000 μg of PEGDE induced epidermal ulcer formation and hair loss. The histology of skin tissue in mice administered with 20,000 μg of PEGDE showed re-epithelialized or unhealed wounds. However, the liver, spleen, and kidneys were histologically normal. Collectively, PEGDE, particularly above 10,000 μg/mouse, caused subcutaneous toxicity with ulceration, but no toxicity in the other organs. These results may indicate the optimal concentration of subcutaneously injected PEGDE.
Collapse
Affiliation(s)
- Do-Hyun Kim
- Toxicology Laboratory, Sanghuh College of Life Science, Konkuk University, 120 Neungdong-ro, Seoul 05029, Korea; (D.-H.K.); (J.-H.H.); (H.-C.K.); (S.-J.L.); (S.-G.H.); (H.-S.J.)
| | - Jong-Hyeon Han
- Toxicology Laboratory, Sanghuh College of Life Science, Konkuk University, 120 Neungdong-ro, Seoul 05029, Korea; (D.-H.K.); (J.-H.H.); (H.-C.K.); (S.-J.L.); (S.-G.H.); (H.-S.J.)
| | - Hyuk-Cheol Kwon
- Toxicology Laboratory, Sanghuh College of Life Science, Konkuk University, 120 Neungdong-ro, Seoul 05029, Korea; (D.-H.K.); (J.-H.H.); (H.-C.K.); (S.-J.L.); (S.-G.H.); (H.-S.J.)
| | - Su-Jin Lim
- Toxicology Laboratory, Sanghuh College of Life Science, Konkuk University, 120 Neungdong-ro, Seoul 05029, Korea; (D.-H.K.); (J.-H.H.); (H.-C.K.); (S.-J.L.); (S.-G.H.); (H.-S.J.)
| | - Seo-Gu Han
- Toxicology Laboratory, Sanghuh College of Life Science, Konkuk University, 120 Neungdong-ro, Seoul 05029, Korea; (D.-H.K.); (J.-H.H.); (H.-C.K.); (S.-J.L.); (S.-G.H.); (H.-S.J.)
| | - Hyun-Su Jung
- Toxicology Laboratory, Sanghuh College of Life Science, Konkuk University, 120 Neungdong-ro, Seoul 05029, Korea; (D.-H.K.); (J.-H.H.); (H.-C.K.); (S.-J.L.); (S.-G.H.); (H.-S.J.)
| | - Keyong-Ho Lee
- R&D Department, Across Co., Ltd., Chuncheon 24398, Korea; (K.-H.L.); (J.-H.K.)
| | - Ju-Hee Kang
- R&D Department, Across Co., Ltd., Chuncheon 24398, Korea; (K.-H.L.); (J.-H.K.)
| | - Sung-Gu Han
- Toxicology Laboratory, Sanghuh College of Life Science, Konkuk University, 120 Neungdong-ro, Seoul 05029, Korea; (D.-H.K.); (J.-H.H.); (H.-C.K.); (S.-J.L.); (S.-G.H.); (H.-S.J.)
- Correspondence:
| |
Collapse
|
5
|
Yagati AK, Ngoc Le HT, Cho S. Bioelectrocatalysis of Hemoglobin on Electrodeposited Ag Nanoflowers toward H 2O 2 Detection. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1628. [PMID: 32825146 PMCID: PMC7557759 DOI: 10.3390/nano10091628] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 08/11/2020] [Accepted: 08/13/2020] [Indexed: 11/29/2022]
Abstract
Hydrogen peroxide (H2O2) is a partially reduced metabolite of oxygen that exerts a diverse array of physiological and pathological activities in living organisms. Therefore, the accurate quantitative determination of H2O2 is crucial in clinical diagnostics, the food industry, and environmental monitoring. Herein we report the electrosynthesis of silver nanoflowers (AgNFs) on indium tin oxide (ITO) electrodes for direct electron transfer of hemoglobin (Hb) toward the selective quantification of H2O2. After well-ordered and fully-grown AgNFs were created on an ITO substrate by electrodeposition, their morphological and optical properties were analyzed with scanning electron microscopy and UV-Vis spectroscopy. Hb was immobilized on 3-mercaptopropionic acid-coated AgNFs through carbodiimide cross-linking to form an Hb/AgNF/ITO biosensor. Electrochemical measurement and analysis demonstrated that Hb retained its direct electron transfer and electrocatalytic properties and acted as a H2O2 sensor with a detection limit of 0.12 µM and a linear detection range of 0.2 to 3.4 mM in phosphate-buffered saline (PBS). The sensitivity, detection limit, and detection range of the Hb/AgNF/ITO biosensor toward detection H2O2 in human serum was also found to be 0.730 mA mM-1 cm-2, 90 µM, and 0.2 to 2.6 mM, indicating the clinical application for the H2O2 detection of the Hb/AgNF/ITO biosensor. Moreover, interference experiments revealed that the Hb/AgNF/ITO sensor displayed excellent selectivity for H2O2.
Collapse
Affiliation(s)
- Ajay Kumar Yagati
- Institute of Analytical Chemistry, Chemo- and Biosensors, Universität Regensburg, 93053 Regensburg, Germany;
| | - Hien T. Ngoc Le
- Department of Electronics Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13210, Korea;
| | - Sungbo Cho
- Department of Electronics Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13210, Korea;
- Gachon Advanced Institute for Health Science & Technology, Gachon University, Incheon 21999, Korea
| |
Collapse
|
6
|
Brown MD, Schoenfisch MH. Electrochemical Nitric Oxide Sensors: Principles of Design and Characterization. Chem Rev 2019; 119:11551-11575. [DOI: 10.1021/acs.chemrev.8b00797] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Micah D. Brown
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, North Carolina 27599, United States
| | - Mark H. Schoenfisch
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, North Carolina 27599, United States
| |
Collapse
|
7
|
Gomes FO, Maia LB, Loureiro JA, Pereira MC, Delerue-Matos C, Moura I, Moura JJ, Morais S. Biosensor for direct bioelectrocatalysis detection of nitric oxide using nitric oxide reductase incorporated in carboxylated single-walled carbon nanotubes/lipidic 3 bilayer nanocomposite. Bioelectrochemistry 2019; 127:76-86. [DOI: 10.1016/j.bioelechem.2019.01.010] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Revised: 01/31/2019] [Accepted: 01/31/2019] [Indexed: 02/07/2023]
|
8
|
Gomes FO, Maia LB, Cordas C, Moura I, Delerue-Matos C, Moura JJG, Morais S. Electroanalytical characterization of the direct Marinobacter hydrocarbonoclasticus nitric oxide reductase-catalysed nitric oxide and dioxygen reduction. Bioelectrochemistry 2018; 125:8-14. [PMID: 30176545 DOI: 10.1016/j.bioelechem.2018.08.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 08/15/2018] [Accepted: 08/19/2018] [Indexed: 02/07/2023]
Abstract
Understanding the direct electron transfer processes between redox proteins and electrode surface is fundamental to understand the proteins mechanistic properties and for development of novel biosensors. In this study, nitric oxide reductase (NOR) extracted from Marinobacter hydrocarbonoclasticus bacteria was adsorbed onto a pyrolytic graphite electrode (PGE) to develop an unmediated enzymatic biosensor (PGE/NOR)) for characterization of NOR direct electrochemical behaviour and NOR electroanalytical features towards NO and O2. Square-wave voltammetry showed the reduction potential of all the four NOR redox centers: 0.095 ± 0.002, -0.108 ± 0.008, -0.328 ± 0.001 and -0.635 ± 0.004 V vs. SCE for heme c, heme b, heme b3 and non-heme FeB, respectively. The determined sensitivity (-4.00 × 10-8 ± 1.84 × 10-9 A/μM and - 2.71 × 10-8 ± 1.44 × 10-9 A/μM for NO and O2, respectively), limit of detection (0.5 μM for NO and 1.0 μM for O2) and the Michaelis Menten constant (2.1 and 7.0 μM for NO and O2, respectively) corroborated the higher affinity of NOR for its natural substrate (NO). No significant interference on sensitivity towards NO was perceived in the presence of O2, while the O2 reduction was markedly and negatively impacted (3.6 times lower sensitivity) by the presence of NO. These results clearly demonstrate the high potential of NOR for the design of innovative NO biosensors.
Collapse
Affiliation(s)
- Filipa O Gomes
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida n° 451, 4249-015 Porto, Portugal; REQUIMTE-LAQV, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal
| | - Luísa B Maia
- REQUIMTE-LAQV, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal
| | - Cristina Cordas
- REQUIMTE-LAQV, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal
| | - Isabel Moura
- REQUIMTE-LAQV, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal
| | - Cristina Delerue-Matos
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida n° 451, 4249-015 Porto, Portugal
| | - José J G Moura
- REQUIMTE-LAQV, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal
| | - Simone Morais
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida n° 451, 4249-015 Porto, Portugal.
| |
Collapse
|
9
|
Nitric Oxide Detection Using Electrochemical Third-generation Biosensors - Based on Heme Proteins and Porphyrins. ELECTROANAL 2018. [DOI: 10.1002/elan.201800421] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
10
|
Musameh MM, Dunn CJ, Uddin MH, Sutherland TD, Rapson TD. Silk provides a new avenue for third generation biosensors: Sensitive, selective and stable electrochemical detection of nitric oxide. Biosens Bioelectron 2018; 103:26-31. [DOI: 10.1016/j.bios.2017.12.019] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 11/30/2017] [Accepted: 12/13/2017] [Indexed: 01/05/2023]
|
11
|
Mayorga-Martinez CC, Sofer Z, Luxa J, Huber Š, Sedmidubský D, Brázda P, Palatinus L, Mikulics M, Lazar P, Medlín R, Pumera M. TaS 3 Nanofibers: Layered Trichalcogenide for High-Performance Electronic and Sensing Devices. ACS NANO 2018; 12:464-473. [PMID: 29227684 DOI: 10.1021/acsnano.7b06853] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Layered materials, like transition metal dichalcogenides, exhibit broad spectra with outstanding properties with huge application potential, whereas another group of related materials, layered transition metal trichalcogenides, remains unexplored. Here, we show the broad application potential of this interesting structural type of layered tantalum trisulfide prepared in a form of nanofibers. This material shows tailorable attractive electronic properties dependent on the tensile strain applied to it. Structure of this so-called orthorhombic phase of TaS3 grown in a form of long nanofibers has been solved and refined. Taking advantage of these capabilities, we demonstrate a highly specific impedimetric NO gas sensor based on TaS3 nanofibers as well as construction of photodetectors with excellent responsivity and field-effect transistors. Various flexible substrates were used for the construction of a NO gas sensor. Such a device exhibits a low limit of detection of 0.48 ppb, well under the allowed value set by environmental agencies for NOx (50 ppb). Moreover, this NO gas sensor also showed excellent selectivity in the presence of common interferences formed during fuel combustion. TaS3 nanofibers produced in large scale exhibited excellent broad application potential for various types of devices covering nanoelectronic, optoelectronic, and gas-sensing applications.
Collapse
Affiliation(s)
- Carmen C Mayorga-Martinez
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences Nanyang Technological University , Nanyang Link 21, Singapore 637371
| | - Zdeněk Sofer
- Department of Inorganic Chemistry, University of Chemistry and Technology Prague , Technická 5, 166 28 Prague 6, Czech Republic
| | - Jan Luxa
- Department of Inorganic Chemistry, University of Chemistry and Technology Prague , Technická 5, 166 28 Prague 6, Czech Republic
| | - Štěpán Huber
- Department of Inorganic Chemistry, University of Chemistry and Technology Prague , Technická 5, 166 28 Prague 6, Czech Republic
| | - David Sedmidubský
- Department of Inorganic Chemistry, University of Chemistry and Technology Prague , Technická 5, 166 28 Prague 6, Czech Republic
| | - Petr Brázda
- Institute of Physics of the CAS , v.v.i., Na Slovance 2, 182 00 Prague 8, Czech Republic
| | - Lukáš Palatinus
- Institute of Physics of the CAS , v.v.i., Na Slovance 2, 182 00 Prague 8, Czech Republic
| | - Martin Mikulics
- Peter Grünberg Institute (PGI-9), Forschungszentrum Jülich, and Jülich-Aachen Research Alliance, JARA, Fundamentals of Future Information Technology, D-52425 Jülich, Germany
| | - Petr Lazar
- Department of Physical Chemistry and Regional Centre of Advanced Technologies and Materials, Palacký University Olomouc , tř. 17. Listopadu 1192/12, 771 46 Olomouc, Czech Republic
| | - Rostislav Medlín
- New Technologies - Research Centre, University of West Bohemia , Univerzitní 8, 306 14 Plzeň, Czech Republic
| | - Martin Pumera
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences Nanyang Technological University , Nanyang Link 21, Singapore 637371
- Department of Inorganic Chemistry, University of Chemistry and Technology Prague , Technická 5, 166 28 Prague 6, Czech Republic
| |
Collapse
|
12
|
Del Caño R, Mateus L, Sánchez-Obrero G, Manuel Sevilla J, Madueño R, Blázquez M, Pineda T. Hemoglobin becomes electroactive upon interaction with surface-protected Au nanoparticles. Talanta 2018; 176:667-673. [PMID: 28917805 DOI: 10.1016/j.talanta.2017.08.090] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2017] [Revised: 08/24/2017] [Accepted: 08/29/2017] [Indexed: 10/18/2022]
Abstract
In this work, we report on the electrochemical behavior of bioconjugates prepared with gold nanoparticles (AuNP) capped with three different molecular layers (citrate anions, 6-mercaptopurine and ω-mercaptoundecanoic acid) and the protein hemoglobin (Hb). Freshly formed bioconjugates are deposited on a glassy carbon electrode and assayed for electroactivity. A pair of redox peaks with formal potential at -0.37V is obtained, in contrast with the free Hb protein that is inactive on the glassy carbon substrate. The redox response is typical for quasi-reversible processes allowing the determination of the electron transfer rate constant for the three bioconjugates. Additional evidence of the structural integrity of protein upon forming the bioconjugate is obtained by monitoring the electrochemical response of the Hb heme Fe(III)/Fe(II) redox couple as a function of solution pH. Moreover, the Hb forming the protein corona around the AuNPs show good electrocatalytic activity for the reduction of hydrogen peroxide and oxygen. It has been found that only the first layer of Hb surrounding the AuNPs are electroactive, although some part of the second layer also contribute, pointing to the role of the AuNP in the electrochemical response.
Collapse
Affiliation(s)
- Rafael Del Caño
- Department of Physical Chemistry and Applied Thermodynamics, Institute of Fine Chemistry and Nanochemistry, University of Cordoba, Campus Rabanales, Ed. Marie Curie 2ª Planta, E-14014 Córdoba, Spain
| | - Lucia Mateus
- Department of Physical Chemistry and Applied Thermodynamics, Institute of Fine Chemistry and Nanochemistry, University of Cordoba, Campus Rabanales, Ed. Marie Curie 2ª Planta, E-14014 Córdoba, Spain
| | - Guadalupe Sánchez-Obrero
- Department of Physical Chemistry and Applied Thermodynamics, Institute of Fine Chemistry and Nanochemistry, University of Cordoba, Campus Rabanales, Ed. Marie Curie 2ª Planta, E-14014 Córdoba, Spain
| | - José Manuel Sevilla
- Department of Physical Chemistry and Applied Thermodynamics, Institute of Fine Chemistry and Nanochemistry, University of Cordoba, Campus Rabanales, Ed. Marie Curie 2ª Planta, E-14014 Córdoba, Spain
| | - Rafael Madueño
- Department of Physical Chemistry and Applied Thermodynamics, Institute of Fine Chemistry and Nanochemistry, University of Cordoba, Campus Rabanales, Ed. Marie Curie 2ª Planta, E-14014 Córdoba, Spain
| | - Manuel Blázquez
- Department of Physical Chemistry and Applied Thermodynamics, Institute of Fine Chemistry and Nanochemistry, University of Cordoba, Campus Rabanales, Ed. Marie Curie 2ª Planta, E-14014 Córdoba, Spain
| | - Teresa Pineda
- Department of Physical Chemistry and Applied Thermodynamics, Institute of Fine Chemistry and Nanochemistry, University of Cordoba, Campus Rabanales, Ed. Marie Curie 2ª Planta, E-14014 Córdoba, Spain.
| |
Collapse
|
13
|
Enhanced electrochemical sensing of nitric oxide using a nanocomposite consisting of platinum-tungsten nanoparticles, reduced graphene oxide and an ionic liquid. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1936-y] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
14
|
Zhou Y, Cao J, Zhao J, Xie Y, Fei J, Cai Y. Temperature-responsive amperometric H2O2 biosensor using a composite film consisting of poly(N-isopropylacrylamide)-b-poly (2-acrylamidoethyl benzoate), graphene oxide and hemoglobin. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1893-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
15
|
Chao J, Zou M, Zhang C, Sun H, Pan D, Pei H, Su S, Yuwen L, Fan C, Wang L. A MoS₂-based system for efficient immobilization of hemoglobin and biosensing applications. NANOTECHNOLOGY 2015; 26:274005. [PMID: 26087018 DOI: 10.1088/0957-4484/26/27/274005] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
A novel hydrogen peroxide (H2O2) and nitric oxide (NO) biosensor was fabricated by immobilizing hemoglobin (Hb) on a gold nanoparticle-decorated MoS2 nanosheet (AuNPs@MoS2) nanocomposite film modified glass carbon electrode. The AuNPs@MoS2 nanocomposite not only made the immobilized Hb keep its native biological activity but also facilitated the electron transfer between electrode and the electroactive center of Hb due to its excellent conductivity and biocompatibility. The direct electrochemistry and bioelectrocatalytic activity of Hb were investigated by cyclic voltammetry (CV). The modified electrode showed good electrocatalytic ability toward the reduction of H2O2 and NO. Under optimal conditions, the current response was linear with the concentration of H2O2 and NO in the range from 10 to 300 μM and 10 to 1100 μM with a detection limit of 4 and 5 μM, respectively. This MoS2-based biosensor was sensitive, reproducible and stable, indicating that AuNPs@MoS2 nanocomposite maybe a promising platform to construct electrochemical sensors for chemical and biological molecules detection.
Collapse
|