1
|
Wu L, Yang F, Xue Y, Gu R, Liu H, Xia D, Liu Y. The biological functions of europium-containing biomaterials: A systematic review. Mater Today Bio 2023; 19:100595. [PMID: 36910271 PMCID: PMC9996443 DOI: 10.1016/j.mtbio.2023.100595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 02/06/2023] [Accepted: 02/22/2023] [Indexed: 03/05/2023] Open
Abstract
The biological functions of rare-earth elements (REEs) have become a focus of intense research. Recent studies have demonstrated that ion doping or alloying of some REEs can optimize the properties of traditional biomaterials. Europium (Eu), which is an REE with low toxicity and good biocompatibility, has promising applications in biomedicine. This article systematically reviews the osteogenic, angiogenic, neuritogenic, antibacterial, and anti-tumor properties of Eu-containing biomaterials, thereby paving the way for biomedical applications of Eu. Data collection for this review was completed in October 2022, and 30 relevant articles were finally included. Most articles indicated that doping of Eu ions or Eu-compound nanoparticles in biomaterials can improve their osteogenic, angiogenic, neuritogenic, antibacterial, and anti-tumor properties. The angiogenic, antibacterial, and potential neuritogenic effects of Eu(OH)3 nanoparticles have also been demonstrated.
Collapse
Affiliation(s)
- Likun Wu
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, 100081, China
- National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, 100081, China
| | - Fan Yang
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, 100081, China
- National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, 100081, China
| | - Yijia Xue
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, 100081, China
- National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, 100081, China
| | - Ranli Gu
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, 100081, China
- National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, 100081, China
| | - Hao Liu
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, 100081, China
- National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, 100081, China
| | - Dandan Xia
- National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, 100081, China
- Department of Dental Materials, Peking University School and Hospital of Stomatology, Beijing, 100081, China
- Corresponding author. Peking University School and Hospital of Stomatology, No.22, Zhongguancun South Avenue, Haidian District, Beijing, 100081, China.
| | - Yunsong Liu
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, 100081, China
- National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health, NMPA Key Laboratory for Dental Materials, Beijing, 100081, China
- Corresponding author. Peking University School and Hospital of Stomatology, No.22, Zhongguancun South Avenue, Haidian District, Beijing, 100081, China.
| |
Collapse
|
2
|
Mohanty A, Parida A, Raut RK, Behera RK. Ferritin: A Promising Nanoreactor and Nanocarrier for Bionanotechnology. ACS BIO & MED CHEM AU 2022; 2:258-281. [PMID: 37101573 PMCID: PMC10114856 DOI: 10.1021/acsbiomedchemau.2c00003] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 04/28/2023]
Abstract
The essence of bionanotechnology lies in the application of nanotechnology/nanomaterials to solve the biological problems. Quantum dots and nanoparticles hold potential biomedical applications, but their inherent problems such as low solubility and associated toxicity due to their interactions at nonspecific target sites is a major concern. The self-assembled, thermostable, ferritin protein nanocages possessing natural iron scavenging ability have emerged as a potential solution to all the above-mentioned problems by acting as nanoreactor and nanocarrier. Ferritins, the cellular iron repositories, are hollow, spherical, symmetric multimeric protein nanocages, which sequester the excess of free Fe(II) and synthesize iron biominerals (Fe2O3·H2O) inside their ∼5-8 nm central cavity. The electrostatics and dynamics of the pore residues not only drives the natural substrate Fe2+ inside ferritin nanocages but also uptakes a set of other metals ions/counterions during in vitro synthesis of nanomaterial. The current review aims to report the recent developments/understanding on ferritin structure (self-assembly, surface/pores electrostatics, metal ion binding sites) and chemistry occurring inside these supramolecular protein cages (protein mediated metal ion uptake and mineralization/nanoparticle formation) along with its surface modification to exploit them for various nanobiotechnological applications. Furthermore, a better understanding of ferritin self-assembly would be highly useful for optimizing the incorporation of nanomaterials via the disassembly/reassembly approach. Several studies have reported the successful engineering of these ferritin protein nanocages in order to utilize them as potential nanoreactor for synthesizing/incorporating nanoparticles and as nanocarrier for delivering imaging agents/drugs at cell specific target sites. Therefore, the combination of nanoscience (nanomaterials) and bioscience (ferritin protein) projects several benefits for various applications ranging from electronics to medicine.
Collapse
|
3
|
Abstract
Inductively coupled plasma mass spectrometry (ICP-MS) has emerged as a promising analytical platform for the quantification of biomolecules using elemental tags; however, absolute quantification at extremely low concentrations by ICP-MS without a calibration curve remains challenging. Here, we developed a digital loop-mediated isothermal amplification (LAMP) assay for counting hepatitis B virus (HBV) DNA using single-particle (sp) ICP-MS. The sample and LAMP reagents were mixed and encapsulated in agarose droplets, which were generated by homemade centrifugal droplet generators. The agarose droplets were incubated at 65 °C for amplifying the virus DNA with LAMP primers and then cooled to 4 °C for generating "gel" particles during the temperature-dependent "sol-gel" transition. The LAMP amplicons were intercalated into the agarose particles using polyacrylamide-modified LAMP primers, enabling the labeling of dsDNA with [Ru(bpy)2dppz]2+ and the removal of excess reagents. Only those agarose particles, containing virus DNA, could be labeled with 101Ru and detected in spICP-MS. We also embedded the 153Eu-containing polystyrene microspheres into agarose droplets as the internal standard for counting the total number of agarose droplets. The copy number of virus DNA could be counted from the 101Ru/153Eu pulse numbers in spICP-MS. We achieved the lowest quantification of 25 copy μL-1 virus DNA in one analysis without the need for a calibration curve. The developed assay can be easily tuned for counting multiple types of nucleic acid targets and extended for new possibilities of the spICP-MS-based digital assay.
Collapse
|
4
|
Xu S, Liu H, Bai Y. Highly sensitive and multiplexed mass spectrometric immunoassay techniques and clinical applications. Anal Bioanal Chem 2022; 414:5121-5138. [PMID: 35165779 DOI: 10.1007/s00216-022-03945-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/17/2022] [Accepted: 01/31/2022] [Indexed: 11/29/2022]
Abstract
Immunoassay is one of the most important clinical techniques for disease/pathological diagnosis. Mass spectrometry (MS) has been a popular and powerful readout technique for immunoassays, generating the mass spectrometric immunoassays (MSIAs) with unbeatable channels for multiplexed detection. The sensitivity of MSIAs has been greatly improved with the development of mass labels from element labels to small-molecular labels. MSIAs are also expended from the representative element MS-based methods to the laser-based organic MS and latest ambient MS, improving in both technology and methodology. Various MSIAs present high potential for clinical applications, including the biomarker screening, the immunohistochemistry, and the advanced single-cell analysis. Here, we give an overall review of the development of MSIAs in recent years, highlighting the latest improvement of mass labels and MS techniques for clinical immunoassays.
Collapse
Affiliation(s)
- Shuting Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, Jiangsu, China.,Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.,Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, Jiangsu, China
| | - Huwei Liu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China
| | - Yu Bai
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.
| |
Collapse
|
5
|
Xu Y, Chen B, He M, Hu B. A homogeneous nucleic acid assay for simultaneous detection of SARS-CoV-2 and influenza A (H3N2) by single-particle inductively coupled plasma mass spectrometry. Anal Chim Acta 2021; 1186:339134. [PMID: 34756259 PMCID: PMC8486417 DOI: 10.1016/j.aca.2021.339134] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 08/14/2021] [Accepted: 08/28/2021] [Indexed: 12/15/2022]
Abstract
In recent years, single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) has become a powerful tool for biological quantitative analysis. Homogeneous analysis method requires no separation and washing steps, which is suited for the analysis of highly infectious pathogens, so as to reduce the risk of infection during the operation. SARS-CoV-2 spreads all over the world, and its early infection symptoms are similar to influenza, which brings inconvenience to triage. Therefore, developing novel analytical method for simultaneous detection of multiple viral nucleic acids is essential. Taking the advantages of SP-ICP-MS and homogeneous analysis strategy, a SP-ICP-MS homogeneous nucleic acid assay by using gold nanoparticles (Au NPs) and silver nanoparticles (Ag NPs) probes was established for simultaneous sensitive analysis of SARS-CoV-2 and influenza A (H3N2). In the present of target SARS-CoV-2 or H3N2 nucleic acids, corresponding Au NPs or Ag NPs probes form larger aggregates, resulting in increased pulse signal intensity and reduced pulse signal frequency of the corresponding NPs in SP-ICP-MS measurement. In this assay, the reaction system of Au NPs and Ag NPs probes does not interfere with each other, and there was no separation and washing procedure, which facilitates operation, saves the analysis time, and improves the analysis efficiency. The linear range of this method is 5-1000 pmol L-1, with low-level limits of quantification of target nucleic acid. The developed SP-ICP-MS simultaneous homogeneous detection method has a good potential for detecting nucleic acid, protein, cell and other biological samples by changing different modification sequences on the NPs probes.
Collapse
|
6
|
Torregrosa D, Grindlay G, Gras L, Mora J. Immunoassays based on inductively coupled plasma mass spectrometry detection: So far so good, so what? Microchem J 2021. [DOI: 10.1016/j.microc.2021.106200] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
7
|
Vlcnovska M, Stossova A, Kuchynka M, Dillingerova V, Polanska H, Masarik M, Hrstka R, Adam V, Kanicky V, Vaculovic T, Vaculovicova M. Comparison of Metal Nanoparticles (Au, Ag, Eu, Cd) Used for Immunoanalysis Using LA-ICP-MS Detection. Molecules 2021; 26:molecules26030630. [PMID: 33530345 PMCID: PMC7865668 DOI: 10.3390/molecules26030630] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/21/2021] [Accepted: 01/22/2021] [Indexed: 12/02/2022] Open
Abstract
Immunochemical methods are used not only in clinical practice for the diagnosis of a wide range of diseases but also in basic and advanced research. Based on the unique reaction between the antibody and its respective antigens, it serves to specifically recognize target molecules in biological complex samples. Current methods of labelling antibodies with elemental labels followed by detection by inductively coupled plasma mass spectrometry (ICP-MS) allow detection of multiple antigens in parallel in a single analysis. Using the laser ablation (LA) modality (LA-ICP-MS), it is also possible to monitor the spatial distribution of biogenic elements. Moreover, the employment of metal nanoparticle-labeled antibodies expands the applicability also to molecular imaging by LA-ICP-MS. In this work, conjugates of model monoclonal antibody (DO-1, recognizing p53 protein) with various metal nanoparticles-based labels were created and utilized in dot-blot analysis in order to compare their benefits and disadvantages. Based on experiments with the p53 protein standard, commercial kits of gold nanoparticles proved to be the most suitable for the preparation of conjugates. The LA-ICP-MS demonstrated very good repeatability, wide linear dynamic range (0.1–14 ng), and limit of detection was calculated as a 1.3 pg of p53 protein.
Collapse
Affiliation(s)
- Marcela Vlcnovska
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Department of Pathological Physiology, Faculty of Medicine, Masaryk University/Kamenice 5, CZ-625 00 Brno, Czech Republic;
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
| | - Aneta Stossova
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Michaela Kuchynka
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Veronika Dillingerova
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Hana Polanska
- Department of Pathological Physiology, Faculty of Medicine, Masaryk University/Kamenice 5, CZ-625 00 Brno, Czech Republic;
| | - Michal Masarik
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Department of Pathological Physiology, Faculty of Medicine, Masaryk University/Kamenice 5, CZ-625 00 Brno, Czech Republic;
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
| | - Roman Hrstka
- Research Centre for Applied Molecular Oncology, Masaryk Memorial Cancer Institute, Zluty kopec 7, CZ-656 53 Brno, Czech Republic;
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
| | - Viktor Kanicky
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Tomas Vaculovic
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Marketa Vaculovicova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
- Correspondence:
| |
Collapse
|
8
|
Ibáñez-Redín G, Joshi N, do Nascimento GF, Wilson D, Melendez ME, Carvalho AL, Reis RM, Gonçalves D, Oliveira ON. Determination of p53 biomarker using an electrochemical immunoassay based on layer-by-layer films with NiFe 2O 4 nanoparticles. Mikrochim Acta 2020; 187:619. [PMID: 33083850 DOI: 10.1007/s00604-020-04594-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 10/07/2020] [Indexed: 01/15/2023]
Abstract
A disposable electrochemical immunosensors is presented suitable to detect cancer biomarker p53 using screen-printed carbon electrodes modified with a layer-by-layer (LbL) matrix of carboxylated NiFe2O4 nanoparticles and polyethyleneimine, onto which anti-p53 antibodies were adsorbed. Under optimized conditions, the immunosensors exhibited high surface coverage and high concentration of immobilized antibodies, which allowed for detection of p53 in a wide dynamic range from 1.0 to 10 × 103 pg mL-1, with a limit of detection of 5.0 fg mL-1 at a working potential of 100 mV vs. Ag/AgCl. The immunosensors also exhibited good selectivity with negligible interference upon incubation in complex matrices containing high concentrations of proteins (i.e., fetal bovine serum and cell lysate). The immunosensor performance is among the best reported in the literature for determination of p53, with the additional advantage of being disposable and operating with low-volume solutions.Graphical abstract Schematic representation of immunosensor fabrication depicting the immobilization of specific antibodies against p53 protein onto the surfaces of disposable printed electrodes modified with films of polyethyleneimine and different concentrations of carboxylated magnetic nanoparticles.
Collapse
Affiliation(s)
- Gisela Ibáñez-Redín
- São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil
| | - Nirav Joshi
- São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil.
| | | | - Deivy Wilson
- São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil
| | - Matias E Melendez
- Pelé Little Prince Research Institute, Little Prince Complex, PR, 80250-060, Curitiba, Brazil.,Molecular Oncology Research Center, Barretos Cancer Hospital, SP, 14784-400, Barretos, Brazil
| | - André L Carvalho
- Molecular Oncology Research Center, Barretos Cancer Hospital, SP, 14784-400, Barretos, Brazil
| | - Rui Manuel Reis
- Molecular Oncology Research Center, Barretos Cancer Hospital, SP, 14784-400, Barretos, Brazil.,Life and eHealth Sciences Research Institute (ICVS), Medical School, University ofMinho, Braga, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga/ Guimarães, Portugal
| | - Débora Gonçalves
- São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil
| | - Osvaldo N Oliveira
- São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil.
| |
Collapse
|
9
|
Nanoparticles as labels of specific-recognition reactions for the determination of biomolecules by inductively coupled plasma-mass spectrometry. Anal Chim Acta 2020; 1128:251-268. [DOI: 10.1016/j.aca.2020.07.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 06/30/2020] [Accepted: 07/01/2020] [Indexed: 02/08/2023]
|
10
|
Jiang W, Sun G, Wen X, Men S, Cui W, Jing M, Jia X, Hu Z, Pu D, Zhang S, Yuan X, Liu X, Zhang X, Wang C. Development and evaluation of an element-tagged immunoassay coupled with inductively coupled plasma mass spectrometry detection: can we apply the new assay in the clinical laboratory? Clin Chem Lab Med 2019; 58:873-882. [PMID: 31639100 DOI: 10.1515/cclm-2019-0566] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2019] [Accepted: 09/22/2019] [Indexed: 01/01/2023]
Abstract
Abstract
Introduction
Element-tagged immunoassay coupled with inductively coupled plasma-mass spectrometry (ICP-MS) detection has the potential to revolutionize immunoassay analysis in clinical detection; however, a systematic evaluation with the standard guidelines of the assay is needed to ensure its performance meets the requirements of the clinical laboratory.
Methods
Carcinoembryonic antigen (CEA) was chosen for analysis using the proposed method. A systematic evaluation of the proposed assay was carried out according to the Clinical and Laboratory Standards Institute (CLSI). The 469 clinical samples were analyzed using the new method and compared with the electrochemiluminescent immunoassay (ECLIA) method.
Results
The measurement range of the assay was 1–900 ng/mL, with a detection limit of 0.83 ng/mL. The inter-assay and intra-assay imprecision were 4.67% and 5.38% with high concentration samples, and 9.27% and 17.64% with low concentration samples, respectively. The cross-reactivity (%) for different antigens was less than 0.05%, and the recovery was between 94% and 108%. Percentage deviation of all the dilutions was less than 12.5% during linearity estimation. The interference bias caused by different substances was less than 10%. The reference interval of the assay was 0–4.442 ng/mL. Comparison with the commercial ECLIA method for clinical sample detection, the proposed method showed a correlation of 0.9878 and no significant differences between the methods were observed (p = 0.6666).
Conclusions
The ICP-MS based immunoassay was successfully developed, and the analytical performance of the assay met the requirements of the CLSI, which fully proved the clinical transferability and application of the new method.
Collapse
Affiliation(s)
- Wencan Jiang
- Department of Clinical Laboratory Medicine , Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Beijing , P.R. China
| | - Gongwei Sun
- Beijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry , Tsinghua University , Beijing , P.R. China
| | - Xinyu Wen
- Department of Clinical Laboratory Medicine , Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Beijing , P.R. China
| | - Shasha Men
- Department of Clinical Laboratory Medicine , Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Beijing , P.R. China
| | - Wenbin Cui
- Chromatography and Mass Spectrometry Thermo Fisher Scientific, China Commercial , Beijing , P.R. China
| | - Miao Jing
- Chromatography and Mass Spectrometry Thermo Fisher Scientific, China Commercial , Beijing , P.R. China
| | - Xingwang Jia
- Department of Clinical Laboratory Medicine , Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Beijing , P.R. China
| | - Zhian Hu
- Beijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry , Tsinghua University , Beijing , P.R. China
| | - Danna Pu
- Department of Clinical Laboratory Medicine , Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Beijing , P.R. China
| | - Sichun Zhang
- Beijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry , Tsinghua University , Beijing , P.R. China
| | - Xiaozhou Yuan
- Department of Clinical Laboratory Medicine , Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Beijing , P.R. China
| | - Xiaoting Liu
- Department of Clinical Laboratory Medicine , Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Beijing , P.R. China
| | - Xinrong Zhang
- Beijing Key Laboratory for Microanalytical Methods and Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084 , P.R. China , Phone: 0086-10-62776888, Fax: 0086-10-62782485
| | - Chengbin Wang
- Department of Clinical Laboratory Medicine, Chinese People’s Liberation Army General Hospital and Postgraduate Medical School , Fuxing Road 28, Haidian District , Beijing 100853 , P.R. China , Phone: +15901056535, Fax: 010-66937771
| |
Collapse
|