1
|
Peng L, Min W, Chen R, Zhang L, Shen B, Xu W, Liu C. PdPtB Electrochemiluminescence Nanoenhancer and SiC@Au-PEDOT Nanowires-Based Detection of β-Amyloid Oligomers in Alzheimer's Disease. ACS APPLIED MATERIALS & INTERFACES 2023; 15:59189-59198. [PMID: 38091553 DOI: 10.1021/acsami.3c14345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2023]
Abstract
β-Amyloid oligomers (AβOs) are promising biomarkers for the diagnosis of Alzheimer's disease (AD). The present research introduces a novel electrochemiluminescence (ECL) immunosensor based on PdPtB nanoenhancer and SiC@Au-PEDOT nanowires (NWs) for the specific and ultrasensitive detection of AβOs. The PdPtB nanoenhancer exhibited excellent oxidase-like catalytic activity with in situ generation of reactive oxygen species (ROS) to enhance luminol ECL in neutral media. In addition, SiC@Au-PEDOT NWs were utilized as a biocompatible and conductive substrate for the modification of the glassy carbon electrode (GCE). With this design, the ECL immunosensor showed outstanding AβOs analytical performance without exogenous coreactant. The ECL immunosensor demonstrated a favorable linear range of 20 pM to 20 nM and a detection limit of 10 pM under optimized conditions with potential straightforward clinical application. In general, the developed ECL immunosensor provides a promising strategy for the early diagnosis of AD.
Collapse
Affiliation(s)
- Lingshuang Peng
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China
| | - Weiziyang Min
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China
- Queen Mary School, Nanchang University, Nanchang 330036, China
| | - Rui Chen
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China
| | - Lu Zhang
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China
| | - Bo Shen
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China
| | - Wenchun Xu
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China
| | - Changjin Liu
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China
| |
Collapse
|
2
|
Itterheimová P, Dosedělová V, Kubáň P. Use of metal nanoparticles for preconcentration and analysis of biological thiols. Electrophoresis 2023; 44:135-157. [PMID: 35892259 DOI: 10.1002/elps.202200142] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 07/11/2022] [Accepted: 07/19/2022] [Indexed: 02/01/2023]
Abstract
Metal nanoparticles (NPs) exhibit several unique physicochemical properties, including redox activity, surface plasmon resonance, ability to quench fluorescence, biocompatibility, or a high surface-to-volume ratio. They are being increasingly used in analysis and preconcentration of thiol containing compounds, because they are able to spontaneously form a stable Au/Ag/Cu-S dative bond. They thus find wide application in environmental and particularly in medical science, especially in the analysis of biological thiols, the endogenous compounds that play a significant role in many biological systems. In this review article, we provide an overview of various types of NPs that have been applied in analysis and preconcentration of biological thiols, mainly in human biological fluids. We first discuss shortly the types of NPs and their synthesis, properties, and their ability to interact with thiol compounds. Then we outline the sample preconcentration and analysis methods that were used for this purpose with special emphasis on optical, electrochemical, and separation techniques.
Collapse
Affiliation(s)
- Petra Itterheimová
- Department of Bioanalytical Instrumentation, Institute of Analytical Chemistry, Czech Academy of Sciences, Brno, Czech Republic.,CEITEC - Central European Institute of Technology, Masaryk University, Brno, Czech Republic
| | - Věra Dosedělová
- Department of Bioanalytical Instrumentation, Institute of Analytical Chemistry, Czech Academy of Sciences, Brno, Czech Republic.,CEITEC - Central European Institute of Technology, Masaryk University, Brno, Czech Republic
| | - Petr Kubáň
- Department of Bioanalytical Instrumentation, Institute of Analytical Chemistry, Czech Academy of Sciences, Brno, Czech Republic
| |
Collapse
|
3
|
Baghal Behyar M, Hasanzadeh M, Seidi F, Shadjou N. Sensing of Amino Acids: Critical role of nanomaterials for the efficient biomedical analysis. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
4
|
Rezaie M, Nemati F, Firoozbakhtian A, Tabesh H, Ganjali MR, Hosseini M. Three‐Dimensional Graphene Network Decorated with Bimetallic Cerium/Copper Oxide Nanoparticles for Non‐Enzymatic Diagnosis of Phenylketonuria. ChemistrySelect 2022. [DOI: 10.1002/slct.202203123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Maryam Rezaie
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| | - Fatemeh Nemati
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| | - Ali Firoozbakhtian
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| | - Hadi Tabesh
- Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran Iran
| | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry School of Chemistry College of Science University of Tehran Tehran 1439817435 Iran
| | - Morteza Hosseini
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| |
Collapse
|
5
|
Sobhanie E, Salehnia F, Xu G, Hamidipanah Y, Arshian S, Firoozbakhtian A, Hosseini M, Ganjali MR, Hanif S. Recent trends and advancements in electrochemiluminescence biosensors for human virus detection. Trends Analyt Chem 2022; 157:116727. [PMID: 35815064 PMCID: PMC9254503 DOI: 10.1016/j.trac.2022.116727] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2022] [Revised: 06/23/2022] [Accepted: 06/28/2022] [Indexed: 11/07/2022]
Abstract
Researchers are constantly looking to find new techniques of virus detection that are sensitive, cost-effective, and accurate. Additionally, they can be used as a point-of-care (POC) tool due to the fact that the populace is growing at a quick tempo, and epidemics are materializing greater often than ever. Electrochemiluminescence-based (ECL) biosensors for the detection of viruses have become one of the most quickly developing sensors in this field. Thus, we here focus on recent trends and developments of these sensors with regard to virus detection. Also, quantitative analysis of various viruses (e.g., Influenza virus, SARS-CoV-2, HIV, HPV, Hepatitis virus, and Zika virus) with a specific interest in Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) was introduced from the perspective of the biomarker and the biological receptor immobilized on the ECL-based sensors, such as nucleic acids-based, immunosensors, and other affinity ECL biosensors.
Collapse
Affiliation(s)
- Ebtesam Sobhanie
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Foad Salehnia
- Departament d'Enginyeria Electrònica, Escola Tècnica Superior d'Enginyeria, Universitat Rovira i Virgili, Avda. Països Catalans 26, 43007, Tarragona, Spain
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, China
| | - Yalda Hamidipanah
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Shayesteh Arshian
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Ali Firoozbakhtian
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Morteza Hosseini
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
- National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran
| | - Saima Hanif
- Department of Biological Sciences, National University of Medical Sciences, Rawalpindi, Islamabad, Pakistan
| |
Collapse
|
6
|
Rezaie M, Nemati F, Firoozbakhtian A, Tabesh H, Hosseini M. Three-dimensional Graphene Network Decorated with Bimetallic Cerium/Copper Oxide Nanoparticles for Non-enzymatic Diagnosis of Phenylketonuria. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
7
|
Hosseini M, Sobhanie E, Salehnia F, Xu G, Rabbani H, Naghavi Sheikholeslami M, Firoozbakhtian A, Sadeghi N, Hossein Farajollah M, Reza Ganjali M, Vosough H. Development of sandwich electrochemiluminescence immunosensor for COVID-19 diagnosis by SARS-CoV-2 spike protein detection based on Au@BSA-luminol nanocomposites. Bioelectrochemistry 2022; 147:108161. [PMID: 35659688 PMCID: PMC9130314 DOI: 10.1016/j.bioelechem.2022.108161] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 04/11/2022] [Accepted: 05/14/2022] [Indexed: 02/04/2023]
Abstract
Coronavirus disease (COVID-19) is a new and highly contagious disease posing a threat to global public health and wreaking havoc around the world. It's caused by the Coronavirus that causes severe acute respiratory syndrome (SARS-CoV-2). In the current pandemic situation, rapid and accurate SARS-CoV-2 diagnosis on a large scale is critical for early-stage diagnosis. Early detection and monitoring of viral infections can aid in controlling and preventing infection in large groups of people. Accordingly, we developed a sensitive and high-throughput sandwich electrochemiluminescence immunosensor based on antigen detection for COVID-19 diagnosis (the spike protein of SARS-CoV-2). For the spike protein of SARS-CoV-2, the ECL biosensor had a linear range of 10 ng mL-1 to 10 µg mL-1 with a limit of detection of 1.93 ng mL-1. The sandwich ECL immunosensor could be used in early clinical diagnosis due to its excellent recovery in detecting SARS-CoV-2, rapid analysis (90 min), and ease of use.
Collapse
Affiliation(s)
- Morteza Hosseini
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran.
| | - Ebtesam Sobhanie
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Foad Salehnia
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China
| | - Hodjattallah Rabbani
- Monoclonal Antibody Research Center, Avicenna Research Institute, ACECR, Tehran, Iran
| | | | - Ali Firoozbakhtian
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Niloufar Sadeghi
- Monoclonal Antibody Research Center, Avicenna Research Institute, ACECR, Tehran, Iran
| | | | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry, School of Chemistry, University of Tehran, Tehran, Iran
| | | |
Collapse
|
8
|
Electrochemiluminescence resonance energy transfer system between ruthenium-based nanosheets and CdS quantum dots for detection of chlorogenic acid. Mikrochim Acta 2022; 189:323. [PMID: 35933502 DOI: 10.1007/s00604-022-05428-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 07/22/2022] [Indexed: 10/15/2022]
Abstract
A new strategy is proposed for ultrasensitive detection of chlorogenic acid (CGA) by fabricating an electrochemiluminescence resonance energy transfer (ECL-RET) sensing platform. The novel system designed by introducing ruthenium-based 2D metal-organic framework nanosheets (Ru@Zn-MOF) as ECL acceptor and L-cysteine capped CdS quantum dots (L-CdS QDs) as ECL donor, exhibited good ECL response. The possible mechanism of the modified electrode surface reaction was discussed. Modifying of the electrode surface by application of L-CdS QDs directly on ultrathin MOF nanosheets greatly shortened the electron-transfer distance and reduce energy loss, therefore significantly improving the ECL efficiency. The prepared sensor demonstrated good stability and highly selective detection of the target molecule. Under optimal conditions, the constructed sensor for the detection of CGA exhibited a wide linear range from 1.0 × 10-10 to 1.0 × 10-4 mol·L-1 and a low detection limit of 3.2 × 10-11 mol·L-1 with a correction coefficient of 0.995. The recovery for spiked samples was calculated to be 94.4-109% and the RSD was 1.07-1.72% in real samples. The obtained sensor is considered to be a promising platform for CGA detection. Electrochemiluminescence resonance energy transfer (ECL-RET) sensing platform is used for the detection for chlorogenic acid.
Collapse
|
9
|
Hosseini M, Hashemian E, Salehnia F, Ganjali MR. Turn-on electrochemiluminescence sensing of melatonin based on graphitic carbon nitride nanosheets. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
10
|
Mirsadoughi E, Nemati F, Oroojalian F, Hosseini M. Turn -on FRET-based cysteine sensor by sulfur-doped carbon dots and Au nanoparticles decorated WS 2 nanosheet. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 272:120903. [PMID: 35123302 DOI: 10.1016/j.saa.2022.120903] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 11/24/2021] [Accepted: 01/12/2022] [Indexed: 06/14/2023]
Abstract
Cysteine is an essential biothiol that plays various functions in the human body. Decrease or exceeding of this excellent antioxidant from the expected range will lead to so many problems. Thus, appropriate sensing of it would be of great importance. Sulfur-doped carbon Dots(S-CDs) owe excellent fluorescence emission. Therefore, designing a Fluorescence resonance energy transfer (FRET) system between S-CDs as donor and Au nanoparticles (AuNPs) decorated tungsten disulfide nanosheet (WS2 NSs) would be a perfect strategy for cysteine detection. Excitation at 340 nm will give the maximum quantum yield of S-CDs (21%) and fluorescence emission peak at 460 nm. In the presence of cysteine, the FRET mechanism inhibited through the affinity of cysteine's functional groups (-SH and -NH2) toward AuNPs and S-CDs fluorescence emission was recovered. To find the best efficiency of the system, optimization of pH, temperature, and time was investigated. Here the linear range of 3-275 µM and limit of detection of 0.01 µM was obtained. Finally, the fluorescence method was applied to the analysis of cysteine in human blood serum, which poses the potential of rapid and sensitive sensing. It can detect both lower and higher amounts of serum cysteine.
Collapse
Affiliation(s)
- Ensiyeh Mirsadoughi
- Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Fatemeh Nemati
- Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Fatemeh Oroojalian
- Department of Advanced Technologies, School of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran; Natural Products and Medicinal Plants Research Center, North Khorasan University of Medical Sciences, Bojnurd, Iran.
| | - Morteza Hosseini
- Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran; Medical Biomaterials Research Center, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
11
|
Impact of gadolinium oxide with functionalized carbon nanosphere: A portable advanced electrocatalyst for pesticide detection in aqueous environmental samples. Talanta 2022; 238:123028. [PMID: 34857347 DOI: 10.1016/j.talanta.2021.123028] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 08/17/2021] [Accepted: 10/31/2021] [Indexed: 11/23/2022]
Abstract
In this study, we developed a portable electrochemical sensor for realizing the pesticide residue in biological, environmental, and vegetable samples. A lower concentration of carbendazim pesticide (CBZ) was electrochemically exposed by newly developed gadolinium oxide/functionalized carbon nanosphere modified glassy carbon electrode (Gd2O3/f-CNS/GCE). The Gd2O3/f-CNS composite was prepared by two-pot ultrasonic-assisted co-precipitation method and characterized by various physicochemical analytical techniques. In addition, the electrocatalytic activity of the composite was investigated by cyclic voltammetry (CV) towards the detection of CBZ. Besides, the Gd2O3/f-CNS/GCE exhibited excellent electrocatalytic capability and sensitivity towards the oxidation of CBZ due to its high electrochemical active surface area, good conductivity, and fast electron transfer ability. A wide linear range of CBZ (0.5-552 μM) was attained with a low level of detection (LOD) of 0.009 μM L-1 and exceptional stability of 93.41%. The proposed sensor exemplifies practical feasibility in blood serum, water, and vegetable samples with an remarkable recovery range of 96.27-99.44% and primary current response of ∼91% after 15 days.
Collapse
|
12
|
Colorimetric determination of cysteine based on Au@Pt nanoparticles as oxidase mimetics with enhanced selectivity. Mikrochim Acta 2021; 189:13. [PMID: 34870756 DOI: 10.1007/s00604-021-05091-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 11/02/2021] [Indexed: 01/03/2023]
Abstract
A H2O2-free colorimetric protocol based on urchin-like Au@Pt nanoparticles (Au@Pt NPs) has been developed for the sensitive and selective determination of cysteine (Cys). We verified the intrinsic oxidase-like activity of the Au@Pt NPs. They can act as artificial mimic oxidases to catalyse the oxidization of 3,3',5,5'-tetramethylbenzidine (TMB) with the assistance of dissolved oxygen, avoiding the use of H2O2 in the colorimetric determination of Cys. In addition, the discrimination of Cys from the other two biothiol analogues, homocysteine and glutathione, can be easily realized through a simple ageing process. HNO3 is added to this colorimetric system to terminate the reaction by oxidizing ox-TMB (oxidized form of TMB) to diphenoquinone (DPQ), thus generating a characteristic absorption peak of DPQ at 450 nm. By recording the absorbance at 450 nm, interference from the aggregated Au@Pt NPs (absorption peak at 670 nm) when 650 nm (the characteristic absorption peak of ox-TMB) is used as the absorption wavelength can be eliminated. We investigated this H2O2-free colorimetric protocol and obtained high sensitivity, with a detection limit of 1.5 nM and relatively high selectivity. The analytical performance for real samples was further explored. The Au@Pt NP-based H2O2-free colorimetric protocol is of great significance for the sensitive and selective determination of Cys in practical samples in different scenarios.
Collapse
|
13
|
An "off-on" electrochemiluminescence biosensor coupled with strand displacement-powered 3D micromolecule walking nanomachine for ultrasensitive detection of adenosine triphosphate. Mikrochim Acta 2021; 188:237. [PMID: 34184148 DOI: 10.1007/s00604-021-04895-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 06/12/2021] [Indexed: 10/21/2022]
Abstract
A three-dimensional (3D) micromolecule walking nanomachine propelled by strand displacement was developed to establish a novel switching electrochemiluminescence (ECL) biosensor for ultrasensitive detection of adenosine triphosphate (ATP). Generally, walking nanomachines reported previously were limited to DNA walkers, while the proposed 3D walking nanomachine focused on the micromolecule walker. Firstly, TiO2 and silver nanoparticles (Ag NPs) functionalized N-(4-aminobutyl)-N-(ethylisoluminol) (Ag-ABEI) were deposited onto the electrode surface to offer an enhanced ECL signal, resulting from the double catalytic effect of TiO2 and Ag NPs for H2O2. Following, dopamine (DA)-labeled DNA duplex probes (S1/S2-DA) immobilized onto the modified electrode cut down the original ECL signal due to the quenching of DA toward ABEI (signal-off). Target ATP walker moved along the 3D DNA track, simultaneously releasing numerous DNA3, which was applied to displace S2-DA, resulting in the quenched ECL intensity recovery (signal-on). As a result, the biosensor showed a low limit of detection down to 0.5 nM (S/N = 3) and was successfully employed to determine ATP in human serum samples. Thus, the established biosensing strategy holds great potential for biochemical studies and clinical diagnosis.
Collapse
|