1
|
Bo Y, Li L, Miao P, Li C, Chang J, Zhang Y, Lv Y, Yang X, Zhang J, Yan M. 2D Z-scheme ZnIn 2S 4/g-C 3N 4 heterojunction based on photoelectrochemical immunosensor with enhanced carrier separation for sensitive detection of CEA. Biosens Bioelectron 2024; 247:115926. [PMID: 38147720 DOI: 10.1016/j.bios.2023.115926] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/28/2023] [Accepted: 12/10/2023] [Indexed: 12/28/2023]
Abstract
Semiconducting materials based on photoelectrochemical (PEC) sensors have been widely utilized for detection. Meanwhile, the sensitivity of the PEC sensor was limited by low-efficiency carrier separation. Thus, a novel sandwich-type PEC bioimmunosensing based on 2D Z-scheme ZnIn2S4/g-C3N4 heterojunction as a photosensitive material and BiVO4 as a photoquencher was designed for the sensitive detection of carcinoembryonic antigen (CEA). Firstly, the 2D ZnIn2S4/g-C3N4 structure provided a multitude of activated sites which facilitated the loading of the capture antibody (Ab1). Secondly, the Z-scheme heterojunction had a high redox capacity while promoting the rapid separation and migration of photogenerated electron-hole pairs (e-/h+). Thus it was able to consume more electron donors to a certain extent, resulting in a higher initial photocurrent. In addition, BiVO4 with large spatial potential resistance was introduced for the first time to realize signal amplification. BiVO4 could not only compete with substrate materials for electron donors, but also effectively prevent electron donors from contacting the substrate, further reducing the photocurrent signal. Under optimized conditions, the sensor had a favorable detection range (0.0001-100 ng/mL) to CEA and a low detection limit of 0.03 pg/mL. With high specificity, excellent stability, and remarkable reproducibility, this sensor provided a new perspective for constructing accurate and convenient PEC immunosensor for bioanalysis and early disease diagnosisdisease diagnosis.
Collapse
Affiliation(s)
- Yiran Bo
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Linrong Li
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Pei Miao
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Chengfang Li
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Jing Chang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Yang Zhang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Yanfeng Lv
- Department of Colorectal and Anal Surgery, The Second Hospital of Shandong University, Jinan 250033, PR China
| | - Xiaofeng Yang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Jing Zhang
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China; Zhejiang Starry Pharmaceutical Co., Ltd. Taizhou, 317300, PR China.
| | - Mei Yan
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
| |
Collapse
|
2
|
Barry SCL, Franke C, Mulaudzi T, Pokpas K, Ajayi RF. Review on Surface-Modified Electrodes for the Enhanced Electrochemical Detection of Selective Serotonin Reuptake Inhibitors (SSRIs). MICROMACHINES 2023; 14:1334. [PMID: 37512646 PMCID: PMC10386609 DOI: 10.3390/mi14071334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 06/19/2023] [Accepted: 06/22/2023] [Indexed: 07/30/2023]
Abstract
Selective serotonin re-uptake inhibitors (SSRIs) are one of the most commonly prescribed classes of antidepressants used for the treatment of moderate to severe depressive disorder, personality disorders and various phobias. This class of antidepressants was created with improved margins of safety. However, genetic polymorphism may be responsible for the high variability in patients' responses to treatment, ranging from failure to delayed therapeutic responses to severe adverse effects of treatment. It is crucial that the appropriate amount of SSRI drugs is administered to ensure the optimum therapeutic efficacy and intervention to minimise severe and toxic effects in patients, which may be the result of accidental and deliberate cases of poisoning. Determining SSRI concentration in human fluids and the environment with high sensitivity, specificity and reproducibility, and at a low cost and real-time monitoring, is imperative. Electrochemical sensors with advanced functional materials have drawn the attention of researchers as a result of these advantages over conventional techniques. This review article aims to present functional materials such as polymers, carbon nanomaterials, metal nanomaterials as well as composites for surface modification of electrodes for sensitive detection and quantification of SSRIs, including fluoxetine, citalopram, paroxetine, fluvoxamine and sertraline. Sensor fabrication, sensor/analyte interactions, design rationale and properties of functional material and the electrocatalytic effect of the modified electrode on SSRI detection are discussed.
Collapse
Affiliation(s)
- Simone C L Barry
- SensorLab Laboratories, Chemistry Department, University of the Western Cape, Bellville 7535, South Africa
| | - Candice Franke
- SensorLab Laboratories, Chemistry Department, University of the Western Cape, Bellville 7535, South Africa
| | - Takalani Mulaudzi
- Biotechnology Department, Life Sciences Building, University of the Western Cape, Bellville 7535, South Africa
| | - Keagan Pokpas
- SensorLab Laboratories, Chemistry Department, University of the Western Cape, Bellville 7535, South Africa
| | - Rachel Fanelwa Ajayi
- SensorLab Laboratories, Chemistry Department, University of the Western Cape, Bellville 7535, South Africa
| |
Collapse
|
3
|
Karimi-Maleh H, Liu Y, Li Z, Darabi R, Orooji Y, Karaman C, Karimi F, Baghayeri M, Rouhi J, Fu L, Rostamnia S, Rajendran S, Sanati AL, Sadeghifar H, Ghalkhani M. Calf thymus ds-DNA intercalation with pendimethalin herbicide at the surface of ZIF-8/Co/rGO/C 3N 4/ds-DNA/SPCE; A bio-sensing approach for pendimethalin quantification confirmed by molecular docking study. CHEMOSPHERE 2023; 332:138815. [PMID: 37146774 DOI: 10.1016/j.chemosphere.2023.138815] [Citation(s) in RCA: 35] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/11/2023] [Accepted: 04/28/2023] [Indexed: 05/07/2023]
Abstract
Pendimethalin (PND) is a herbicide that is regarded to be possibly carcinogenic to humans and toxic to the environment. Herein, we fabricated a highly sensitive DNA biosensor based on ZIF-8/Co/rGO/C3N4 nanohybrid modification of a screen-printed carbon electrode (SPCE) to monitor PND in real samples. The layer-by-layer fabrication pathway was conducted to construct ZIF-8/Co/rGO/C3N4/ds-DNA/SPCE biosensor. The physicochemical characterization techniques confirmed the successful synthesis of ZIF-8/Co/rGO/C3N4 hybrid nanocomposite, as well as the appropriate modification of the SPCE surface. The utilization of ZIF-8/Co/rGO/C3N4 nanohybrid as a modifier was analyzed using. The electrochemical impedance spectroscopy results showed that the modified SPCE exhibited significantly lowered charge transfer resistance due to the enhancement of its electrical conductivity and facilitation of the transfer of charged particles. The proposed biosensor successfully quantified PND in a wide concentration range of 0.01-35 μM, with a limit of detection (LOD) value of 8.0 nM. The PND monitoring capability of the fabricated biosensor in real samples including rice, wheat, tap, and river water samples was verified with a recovery range of 98.2-105.6%. Moreover, to predict the interaction sites of PND herbicide with DNA, the molecular docking study was performed between the PND molecule and two sequence DNA fragments and confirmed the experimental findings. This research sets the stage for developing highly sensitive DNA biosensors that will be used to monitor and quantify toxic herbicides in real samples by fusing the advantages of nanohybrid structures with crucial knowledge from a molecular docking investigation.
Collapse
Affiliation(s)
- Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China; Department of Sustainable Engineering, Saveetha School of Engineering, SIMATS, Chennai, 602105, India; Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, 2028, Johannesburg, 17011, South Africa.
| | - Yuezhen Liu
- The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, Quzhou, 324000, China.
| | - Zhangping Li
- The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, Quzhou, 324000, China.
| | - Rozhin Darabi
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China
| | - Yasin Orooji
- College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Ceren Karaman
- Department of Electricity and Energy, Akdeniz University, Antalya, 07070, Turkey; School of Engineering, Lebanese American University, Byblos, Lebanon.
| | - Fatemeh Karimi
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China
| | - Mehdi Baghayeri
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, PO. Box 397, Sabzevar, Iran
| | - Jalal Rouhi
- Faculty of Physics, University of Tabriz, Tabriz, 51566, Iran
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Sadegh Rostamnia
- Organic and Nano Group (ONG), Department of Chemistry, Iran University of Science and Technology (IUST), PO Box 16846-13114, Tehran, Iran
| | - Saravanan Rajendran
- Faculty of Engineering, Department of Mechanical Engineering, University of Tarapac´a, Avda, General Velasquez, 1775, Arica, Chile
| | - Afsaneh L Sanati
- Institute of Systems and Robotics, Department of Electrical and Computer Engineering, University of Coimbra, Polo II, 3030-290, Coimbra, Portugal
| | - Hasan Sadeghifar
- Hollingsworth & Vose, R&D Center, 219 Townsend Road, Groton, MA, 01450, USA
| | - Masoumeh Ghalkhani
- Electrochemical Sensors Research Laboratory, Department of Chemistry, Faculty of Science, Shahid Rajaee Teacher Training University, Tehran, Iran
| |
Collapse
|
4
|
Rahman H, Rafi M, Putra BR, Wahyuni WT. Electrochemical Sensors Based on a Composite of Electrochemically Reduced Graphene Oxide and PEDOT:PSS for Hydrazine Detection. ACS OMEGA 2023; 8:3258-3269. [PMID: 36713748 PMCID: PMC9878640 DOI: 10.1021/acsomega.2c06791] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 12/28/2022] [Indexed: 05/27/2023]
Abstract
In this study, hydrazine sensors were developed from a composite of electrochemically reduced graphene oxide (ErGO) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS), deposited onto a glassy carbon electrode (GCE). The structural properties, electrochemical characterization, and surface morphologies of this hydrazine sensor were characterized by Raman spectroscopy, Fourier transform infrared (FTIR) spectroscopy, electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). In addition, the proposed hydrazine sensor also demonstrates good electrochemical and analytical performance when investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometry techniques under optimal parameters. Using these investigated parameters, DPV and amperometry were chosen as techniques for hydrazine measurements and showed a linear range of concentration in the range of 0.2-100 μM. The obtained limits of detection and limits of quantitation for hydrazine measurements were 0.01 and 0.03 μM, respectively. In addition, the proposed sensor demonstrated good reproducibility and stability in hydrazine measurements in eight consecutive days. This fabricated hydrazine sensor also exhibited good selectivity against interference from Mg2+, K+, Zn2+, Fe2+, Na+, NO2 -, CH3COO-, SO4 2-, Cl-, ascorbic acid, chlorophenol, and triclosan and combined interferences, as well as it depicted %RSD values of less than 5%. In conclusion, this proposed sensor based on GCE modified with ErGO/PEDOT:PSS displays exceptional electrochemical performance for use in hydrazine measurements and have the potential to be employed in practical applications.
Collapse
Affiliation(s)
- Hemas
Arif Rahman
- Department
of Chemistry, Faculty of Mathematics and Natural Sciences, IPB University, Bogor, West Java16680, Indonesia
| | - Mohamad Rafi
- Department
of Chemistry, Faculty of Mathematics and Natural Sciences, IPB University, Bogor, West Java16680, Indonesia
- Tropical
Biopharmaca Research Center, Institute of
Research and Community Empowerment, IPB University, Bogor, West Java16680, Indonesia
| | - Budi Riza Putra
- Research
Center for Metallurgy, National Research
and Innovation Agency (BRIN), PUSPIPTEK Area, Building No. 470, Setu Regency, South Tangerang, Banten15314, Indonesia
| | - Wulan Tri Wahyuni
- Department
of Chemistry, Faculty of Mathematics and Natural Sciences, IPB University, Bogor, West Java16680, Indonesia
- Tropical
Biopharmaca Research Center, Institute of
Research and Community Empowerment, IPB University, Bogor, West Java16680, Indonesia
| |
Collapse
|
5
|
Wei B, Zhang L, Guan YL, Fu LJ, Wang H, Chi JY, Jiang ZQ, Wang XD, Yu HH. Synthesis, characterisation and photocatalytic properties of visible light responsive Co2Co4(SiW10O37)2/Fe2O3 composites. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02398-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
6
|
Karimi-Maleh H, Darabi R, Shabani-Nooshabadi M, Baghayeri M, Karimi F, Rouhi J, Alizadeh M, Karaman O, Vasseghian Y, Karaman C. Determination of D&C Red 33 and Patent Blue V Azo dyes using an impressive electrochemical sensor based on carbon paste electrode modified with ZIF-8/g-C 3N 4/Co and ionic liquid in mouthwash and toothpaste as real samples. Food Chem Toxicol 2022; 162:112907. [PMID: 35271984 DOI: 10.1016/j.fct.2022.112907] [Citation(s) in RCA: 119] [Impact Index Per Article: 59.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Revised: 02/22/2022] [Accepted: 03/05/2022] [Indexed: 12/17/2022]
Abstract
Synthetic azo dyes are widely used in a variety of industries, but many of them pose a risk to human health, particularly when consumed in large quantities. As a result, their existence in products should be closely monitored. D&C red 33 and Patent Blue V are mostly used in cosmetics, especially in toothpaste and mouthwashes. A novel carbon paste electrode modified with ZIF-8/g-C3N4/Co nanocomposite and 1-methyl-3-butylimidazolium bromide as an ionic liquid was employed as a highly sensitive reproducible electrochemical sensor for the simultaneous determination of these common dyes. ZIF structure has unique properties such as high surface area, suitable conductivity, and excellent porosity. The electrochemical behavior of the suggested electrode was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). To characterize the synthesized nanocomposites, scanning electron microscopy (SEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) were applied to investigate the structure of nanocomposites. Under the optimized conditions, the modified sensor offered a wide linear concentration range 0.08-10 μM (R2 = 0.9906) and 10-900 μM (R2 = 0.9932) with a low limit of detection of 0.034 μM. The value of diffusion coefficient (D), and the electron transfer coefficient (α) was calculated to be 310 × 10-5, and 0.9 respectively. This technique offered a successful performance for the determination of target analyte in the real samples with acceptable results between 96% and 107%.
Collapse
Affiliation(s)
- Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, Chengdu, 611731, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran; Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, 2028, Johannesburg, South Africa.
| | - Rozhin Darabi
- Institute of Nano Science and Nano Technology, University of Kashan, Kashan, Iran; Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan, Iran
| | - Mehdi Shabani-Nooshabadi
- Institute of Nano Science and Nano Technology, University of Kashan, Kashan, Iran; Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan, Iran.
| | - Mehdi Baghayeri
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, Sabzevar, 397, Iran
| | - Fatemeh Karimi
- Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran
| | - Jalal Rouhi
- Faculty of Physics, University of Tabriz, Tabriz, 51566, Iran
| | - Marzieh Alizadeh
- Pharmaceutical Sciences Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Laboratory of Basic Sciences, Mohammad Rasul Allah Research Tower, Shiraz University of Medical Sciences, Shiraz, 234567890, Iran
| | - Onur Karaman
- Department of Medical Imaging Techniques, Vocational School of Health Services, Akdeniz University, Antalya, 07070, Turkey
| | - Yasser Vasseghian
- Department of Chemistry, Soongsil University, Seoul, 06978, South Korea
| | - Ceren Karaman
- Department of Electricity and Energy, Vocational School of Technical Sciences, Akdeniz University, Antalya, 07070, Turkey.
| |
Collapse
|
7
|
Au-modified the hollow ZnSnO3 cubes with high performance for hydrazine electrochemical sensing. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
8
|
Simultaneous determination of citalopram and selegiline using an efficient electrochemical sensor based on ZIF-8 decorated with RGO and g-C3N4 in real samples. Anal Chim Acta 2022; 1203:339662. [DOI: 10.1016/j.aca.2022.339662] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 02/10/2022] [Accepted: 02/25/2022] [Indexed: 12/11/2022]
|
9
|
Lu X, Zhang F, Sun Y, Yu K, Guo W, Qu F. A 2D/2D NiCo-MOF/Ti 3C 2 heterostructure for the simultaneous detection of acetaminophen, dopamine and uric acid by differential pulse voltammetry. Dalton Trans 2021; 50:16593-16600. [PMID: 34746941 DOI: 10.1039/d1dt03208a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A 2D/2D NiCo-MOF/Ti3C2 heterojunction is constructed as a non-enzymatic biosensor for the simultaneous electrochemical detection of acetaminophen (AP), dopamine (DA), and uric acid (UA) via differential pulse voltammetry. Benefiting from the synergistic effects of the high electrocatalytic activity of NiCo-MOF, the outstanding conductivity of Ti3C2, and the improved specific surface area of NiCo-MOF/Ti3C2, NiCo-MOF/Ti3C2 displays high sensing performance toward AP (0.01-400 μM), DA (0.01-300 μM), and UA (0.01-350 μM) in 0.1 M phosphate buffer (PB, pH 7.4) at working potentials of 0.346 V vs. SCE for AP, 0.138 V vs. SCE for DA, and 0.266 V vs. SCE for UA. Furthermore, the well-separated oxidation peak potentials allow for the simultaneous detection of the analytes, with detection limits of 0.008, 0.004, and 0.006 μM (S/N = 3), respectively. As a result of its considerable reproducibility and anti-interference and anti-fouling properties, NiCo-MOF/Ti3C2 was also developed into a practical sensing platform to detect AP, DA, and UA in serum and urine, presenting excellent recoveries of 98.1-102.2 %.
Collapse
Affiliation(s)
- Xing Lu
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, Harbin Normal University, Harbin 150025, P. R. China.
| | - Feng Zhang
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, Harbin Normal University, Harbin 150025, P. R. China. .,Key Laboratory of Photonic and Electronic Bandgap Materials, Ministry of Education, Harbin Normal University, Harbin 150025, P. R. China
| | - Yimeng Sun
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, Harbin Normal University, Harbin 150025, P. R. China.
| | - Kai Yu
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, Harbin Normal University, Harbin 150025, P. R. China.
| | - Wei Guo
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, Harbin Normal University, Harbin 150025, P. R. China.
| | - Fengyu Qu
- Key Laboratory of Photochemical Biomaterials and Energy Storage Materials, Heilongjiang Province, Harbin Normal University, Harbin 150025, P. R. China. .,Key Laboratory of Photonic and Electronic Bandgap Materials, Ministry of Education, Harbin Normal University, Harbin 150025, P. R. China
| |
Collapse
|