1
|
Hernández-Rodríguez JF, Trachioti MG, Hrbac J, Rojas D, Escarpa A, Prodromidis MI. Spark-Discharge-Activated 3D-Printed Electrochemical Sensors. Anal Chem 2024; 96:10127-10133. [PMID: 38867513 PMCID: PMC11209655 DOI: 10.1021/acs.analchem.4c01249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 05/11/2024] [Accepted: 06/04/2024] [Indexed: 06/14/2024]
Abstract
3D printing technology is a tremendously powerful technology to fabricate electrochemical sensing devices. However, current conductive filaments are not aimed at electrochemical applications and therefore require intense activation protocols to unleash a suitable electrochemical performance. Current activation methods based on (electro)chemical activation (using strong alkaline solutions and organic solvents and/or electrochemical treatments) or combined approaches are time-consuming and require hazardous chemicals and dedicated operator intervention. Here, pioneering spark-discharge-activated 3D-printed electrodes were developed and characterized, and it was demonstrated that their electrochemical performance was greatly improved by the effective removal of the thermoplastic support polylactic acid (PLA) as well as the formation of sponge-like and low-dimensional carbon nanostructures. This reagent-free approach consists of a direct, fast, and automatized spark discharge between the 3D-electrode and the respective graphite pencil electrode tip using a high-voltage power supply. Activated electrodes were challenged toward the simultaneous voltammetric determination of dopamine (DP) and serotonin (5-HT) in cell culture media. Spark discharge has been demonstrated as a promising approach for conductive filament activation as it is a fast, green (0.94 GREEnness Metric Approach), and automatized procedure that can be integrated into the 3D printing pipeline.
Collapse
Affiliation(s)
- Juan F. Hernández-Rodríguez
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares 28802, Madrid, Spain
| | - Maria G. Trachioti
- Department
of Chemistry, University of Ioannina, 45 110 Ioannina, Greece
| | - Jan Hrbac
- Department
of Chemistry, Masaryk University, 625 00 Brno, Czech Republic
| | - Daniel Rojas
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares 28802, Madrid, Spain
| | - Alberto Escarpa
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares 28802, Madrid, Spain
- Chemical
Research Institute “Andres M. Del Rio”, University of Alcalá, Alcalá
de Henares 28802, Madrid, Spain
| | | |
Collapse
|
2
|
de Faria LV, Villafuerte LM, do Nascimento SFL, de Sá IC, Peixoto DA, Ribeiro RSDA, Nossol E, Lima TDM, Semaan FS, Pacheco WF, Dornellas RM. 3D-printed electrodes using graphite/carbon nitride/polylactic acid composite material: A greener platform for detection of amaranth dye in food samples. Food Chem 2024; 442:138497. [PMID: 38271904 DOI: 10.1016/j.foodchem.2024.138497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 12/27/2023] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
The production of sustainable materials with properties aimed at the additive manufacturing of electrochemical sensors has gained prestige in the scientific scenario. Here, a novel lab-made composite material using graphite (G) and carbon nitride (C3N4) embedded into polylactic acid (PLA) biopolymer is proposed to produce 3D-printed electrodes. PLA offers printability and mechanical stability in this composition, while G and C3N4 provide electrical properties and electrocatalytic sites, respectively. Characterizations by Raman and infrared spectroscopies and Energy Dispersive X-rays indicated that the G/C3N4/PLA composite was successfully obtained, while electron microscopy images revealed non-homogeneous rough surfaces. Better electrochemical properties were achieved when the G/C3N4/PLA proportion (35:5:60) was used. As a proof of concept, amaranth (AMR), a synthetic dye, was selected as an analyte, and a fast method using square wave voltammetry was developed. Utilizing the 3D-printed G/C3N4/PLA electrode, a more comprehensive linear range (0.2 to 4.2 μmol/L), a 5-fold increase in sensitivity (9.83 μmol-1 L μA), and better limits of detection (LOD = 0.06 μmol/L) and quantification (LOQ = 0.18 μmol/L) were achieved compared to the G/PLA electrode. Samples of jelly, popsicles, isotonic drinks, and food flavoring samples were analyzed, and similar results to those obtained by UV-vis spectrometry confirmed the method's reliability. Therefore, the described sensor is a simple, cost-effective alternative for assessing AMR in routine food analysis.
Collapse
Affiliation(s)
- Lucas V de Faria
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil.
| | - Luana M Villafuerte
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Suéllen F L do Nascimento
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Igor C de Sá
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Diego A Peixoto
- Instituto de Química, Universidade Federal de Uberlândia, 38408-100 Uberlândia-MG, Brazil
| | - Ruan S de A Ribeiro
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Edson Nossol
- Instituto de Química, Universidade Federal de Uberlândia, 38408-100 Uberlândia-MG, Brazil
| | - Thiago de M Lima
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Felipe S Semaan
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Wagner F Pacheco
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Rafael M Dornellas
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil.
| |
Collapse
|
3
|
Wong TI, Ng C, Lin S, Chen Z, Zhou X. Adaptive Fabrication of Electrochemical Chips with a Paste-Dispensing 3D Printer. SENSORS (BASEL, SWITZERLAND) 2024; 24:2844. [PMID: 38732950 PMCID: PMC11086071 DOI: 10.3390/s24092844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/25/2024] [Accepted: 04/28/2024] [Indexed: 05/13/2024]
Abstract
Electrochemical (EC) detection is a powerful tool supporting simple, low-cost, and rapid analysis. Although screen printing is commonly used to mass fabricate disposable EC chips, its mask is relatively expensive. In this research, we demonstrated a method for fabricating three-electrode EC chips using 3D printing of relatively high-viscosity paste. The electrodes consisted of two layers, with carbon paste printed over silver/silver chloride paste, and the printed EC chips were baked at 70 °C for 1 h. Engineering challenges such as bulging of the tubing, clogging of the nozzle, dripping, and local accumulation of paste were solved by material selection for the tube and nozzle, and process optimization in 3D printing. The EC chips demonstrated good reversibility in redox reactions through cyclic voltammetry tests, and reliably detected heavy metal ions Pb(II) and Cd(II) in solutions using differential pulse anodic stripping voltammetry measurements. The results indicate that by optimizing the 3D printing of paste, EC chips can be obtained by maskless and flexible 3D printing techniques in lieu of screen printing.
Collapse
Affiliation(s)
- Ten It Wong
- Institute of Materials Research and Engineering, A*STAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore;
| | - Candy Ng
- School of Materials Science & Engineering, Nanyang Technological University, Block N4.1, Nanyang Avenue, Singapore 639798, Singapore; (C.N.); (Z.C.)
| | - Shengxuan Lin
- Residues and Resource Reclamation Centre (R3C), Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Clean Tech One, Singapore 637141, Singapore;
| | - Zhong Chen
- School of Materials Science & Engineering, Nanyang Technological University, Block N4.1, Nanyang Avenue, Singapore 639798, Singapore; (C.N.); (Z.C.)
| | - Xiaodong Zhou
- Institute of Materials Research and Engineering, A*STAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore;
| |
Collapse
|
4
|
Lisboa TP, de Faria LV, de Oliveira WBV, Oliveira RS, de Souza CC, Matos MAC, Dornellas RM, Matos RC. Simultaneous monitoring of amoxicillin and paracetamol in synthetic biological fluids using a 3D printed disposable electrode with a lab-made conductive filament. Anal Bioanal Chem 2024; 416:215-226. [PMID: 37923939 DOI: 10.1007/s00216-023-05009-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 10/09/2023] [Accepted: 10/12/2023] [Indexed: 11/06/2023]
Abstract
In this work, we are pleased to present for the first time a 3D-printed electrochemical device using a lab-made conductive filament based on graphite (Gr) and polylactic acid (PLA) polymer matrix for the simultaneous detection of amoxicillin (AMX) and paracetamol (PAR). The sensor was properly characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Compared to the commercial glassy carbon electrode (GCE), the superior performance of the 3D-Gr/PLA electrode was verified with a 3.8-fold more favored charge transfer. A differential pulse voltammetry (DPV) method was proposed providing a linear working range of 4 to 12 μmol L-1 for both analytes and a limit of detection (LOD) of 0.80 and 0.51 μmol L-1 for AMX and PAR, respectively. Additionally, repeatability studies (n = 5, RSD < 5.7%) indicated excellent precision, and recovery percentages ranging from 89 to 109% when applied to synthetic human urine, saliva, and plasma samples, attested to the accuracy of the method. The studies also indicate that the sensor does not suffer significant interference from common substances (antibiotics and biomarkers) present in the biological fluids, which makes it a promising analytical tool considering its low-cost, ease of manufacturing, robustness, and electrochemical performance.
Collapse
Affiliation(s)
- Thalles Pedrosa Lisboa
- Chemistry Department, Federal University of Juiz de Fora, Juiz de Fora, 36036-900, Brazil.
- FACET, Great Dourados Federal University, Dourados, 79804-970, Brazil.
| | | | | | - Raylla Santos Oliveira
- Chemistry Department, Federal University of Juiz de Fora, Juiz de Fora, 36036-900, Brazil
| | | | | | | | - Renato Camargo Matos
- Chemistry Department, Federal University of Juiz de Fora, Juiz de Fora, 36036-900, Brazil.
| |
Collapse
|
5
|
Hernández-Rodríguez JF, Rojas D, Escarpa A. Print-Pause-Print Fabrication of Tailored Electrochemical Microfluidic Devices. Anal Chem 2023; 95:18679-18684. [PMID: 38095628 PMCID: PMC10753525 DOI: 10.1021/acs.analchem.3c03364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 11/23/2023] [Accepted: 11/24/2023] [Indexed: 12/27/2023]
Abstract
Three-dimensional (3D) printing technology has emerged as a powerful technology for the fabrication of low-cost microfluidics. Nevertheless, the fabrication of microfluidic devices integrating high-performance electrochemical sensors in practical applications is still an open challenge. Although automatic fabrication of the microfluidic device and the electrodes can be successfully carried out using a one-step multimaterial fused filament fabrication (FFF) approach, the as-printed electrochemical performance of these electrodes is not good enough for chemical (bio)sensing and their surface modification is challenging because after closing the channel there is no physical access to the electrode. Thus, here a pause-print-pause (PPP) microfabrication approach was implemented. The fabrication was paused before printing the microfluidics, and the filament-based electrodes were directly modified on the printing bed via stencil printing, drop casting, and electrodeposition. To exemplify this versatile workflow, the design of a microfluidic glucose sensor was proposed. To this end, first, the working and counter electrodes were stencil printed with graphite ink while the reference electrode was stencil printed with Ag|AgCl ink. Then, Prussian blue was formed on the working electrode either by drop casting or by electrodeposition, and glucose oxidase was drop cast on top. At this point, the microfabrication process was resumed, and the microfluidics were printed on top of the modified electrodes to complete the construction of hybrid electrochemical fluidic fused filament fabricated devices (h-eF4Ds). This print-pause-print approach is not limited to ink-based electrodes or glucose oxidase, and we envisage these results will pave the way for the effective integration of electrodes in microfluidic devices in a simple and clean-room-free approach, allowing the development of highly customized eF4Ds for a plethora of analytes with high significance.
Collapse
Affiliation(s)
- Juan F. Hernández-Rodríguez
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
| | - Daniel Rojas
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
| | - Alberto Escarpa
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
- Chemical
Research Institute “Andres M. Del Rio”, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
| |
Collapse
|
6
|
de Faria LV, do Nascimento SFL, Villafuerte LM, Semaan FS, Pacheco WF, Dornellas RM. 3D printed graphite-based electrode coupled with batch injection analysis: An affordable high-throughput strategy for atorvastatin determination. Talanta 2023; 265:124873. [PMID: 37390670 DOI: 10.1016/j.talanta.2023.124873] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 06/19/2023] [Accepted: 06/21/2023] [Indexed: 07/02/2023]
Abstract
This work integrated a lab-made conductive graphite/polylactic acid (Grp/PLA, 40:60% w/w) filament into a 3D pen to print customized electrodes (cylindrical design). Thermogravimetric analysis validated the incorporation of graphite into the PLA matrix, while Raman spectroscopy and scanning electron microscopy images indicated a graphitic structure with the presence of defects and highly porous, respectively. The electrochemical features of the 3D-printed Gpt/PLA electrode were systematically compared to that achieved using commercial carbon black/polylactic acid (CB/PLA, from Protopasta®) filament. The 3D printed Gpt/PLA electrode "in the native form" provided lower charge transfer resistance (Rct = 880 Ω) and a more kinetically favored reaction (K0 = 1.48 × 10-3 cm s-1) compared to the 3D printed CB/PLA electrode (chemically/electrochemically treated). Moreover, a method by batch injection analysis with amperometric detection (BIA-AD) was developed to determine atorvastatin (ATR) in pharmaceutical and water samples. Using the 3D printed Gpt/PLA electrode, a wider linear range (1-200 μmol L-1), sensitivity (3-times higher), and lower detection limit (LOD = 0.13 μmol L-1) were achieved when compared to the CB/PLA electrode. Repeatability studies (n = 15, RSD <7.3%) attested to the precision of the electrochemical measurements, and recovery percentages between 83 and 108% confirmed the accuracy of the method. Remarkably, this is the first time that ATR has been determined by the BIA-AD system and a low-cost 3D-printed device. This approach is promising to be implemented in research laboratories for quality control of pharmaceuticals and can also be useful for on-site environmental analysis.
Collapse
Affiliation(s)
- Lucas V de Faria
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141, Niterói, RJ, Brazil.
| | - Suéllen F L do Nascimento
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141, Niterói, RJ, Brazil
| | - Luana M Villafuerte
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141, Niterói, RJ, Brazil
| | - Felipe S Semaan
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141, Niterói, RJ, Brazil
| | - Wagner F Pacheco
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141, Niterói, RJ, Brazil
| | - Rafael M Dornellas
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141, Niterói, RJ, Brazil.
| |
Collapse
|
7
|
Chang Y, Cao Q, Venton BJ. 3D printing for customized carbon electrodes. CURRENT OPINION IN ELECTROCHEMISTRY 2023; 38:101228. [PMID: 36911532 PMCID: PMC9997447 DOI: 10.1016/j.coelec.2023.101228] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Traditional carbon electrodes are made of glassy carbon or carbon fibers and have limited shapes. 3D printing offers many advantages for manufacturing carbon electrodes, such as complete customization of the shape and the ability to fabricate devices and electrodes simultaneously. Additive manufacturing is the most common 3D printing method, where carbon materials are added to the material to make it conductive, and treatments applied to enhance electrochemical activity. A newer form of 3D printing is 2-photon lithography, where electrodes are printed in photoresist via laser lithography and then annealed to carbon by pyrolysis. Applications of 3D printed carbon electrodes include nanoelectrode measurements of neurotransmitters, arrays of biosensors, and integrated electrodes in microfluidic devices.
Collapse
Affiliation(s)
- Yuanyu Chang
- Department of Chemistry, University of Virginia, Charlottesville, VA, 22904
| | - Qun Cao
- Department of Chemistry, University of Virginia, Charlottesville, VA, 22904
| | - B Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, VA, 22904
| |
Collapse
|
8
|
Silva-Neto HA, Duarte-Junior GF, Rocha DS, Bedioui F, Varenne A, Coltro WKT. Recycling 3D Printed Residues for the Development of Disposable Paper-Based Electrochemical Sensors. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 36884339 DOI: 10.1021/acsami.3c00370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Here, we propose a recyclable approach using acrylonitrile-butadiene-styrene (ABS) residues from additive manufacturing in combination with low-cost and accessible graphite flakes as a novel and potential mixture for creating a conductive paste. The graphite particles were successfully incorporated in the recycled thermoplastic composite when solubilized with acetone and the mixture demonstrated greater adherence to different substrates, among which cellulose-based material made possible the construction of a paper-based electrochemical sensor (PES). The morphological, structural, and electrochemical characterizations of the recycled electrode material were demonstrated to be similar to those of the traditional carbon-based surfaces. Faradaic responses based on redox probe activity ([Fe(CN)6]3-/4-) exhibited well-defined peak currents and diffusional mass transfer as a quasi-reversible system (96 ± 5 mV) with a fast heterogeneous rate constant value of 2 × 10-3 cm s-1. To improve the electrode electrochemical properties, both the PES and the classical 3D-printed electrode surfaces were modified with a combination of multiwalled carbon nanotubes (MWCNTs), graphene oxide (GO), and copper. Both electrode surfaces demonstrated the suitable oxidation of nitrite at 0.6 and 0.5 V vs Ag, respectively. The calculated analytical sensitivities for PES and 3D-printed electrodes were 0.005 and 0.002 μA/(μmol L-1), respectively. The proposed PES was applied for the indirect amperometric analysis of S-nitroso-cysteine (CysNO) in serum samples via nitrite quantitation, demonstrating a limit of detection of 4.1 μmol L-1, with statistically similar values when compared to quantitative analysis of the same samples by spectrophotometry (paired t test, 95% confidence limit). The evaluated electroanalytical approach exhibited linear behavior for nitrite in the concentration range between 10 and 125 μmol L-1, which is suitable for realizing clinical diagnosis involving Parkinson's disease, for example. This proof of concept shows the great promise of this recyclable strategy combining ABS residues and conductive particles in the context of green chemical protocols for constructing disposable sensors.
Collapse
Affiliation(s)
- Habdias A Silva-Neto
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO Brazil
| | | | - Danielly S Rocha
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO Brazil
| | - Fethi Bedioui
- Institute of Chemistry for Life and Health Sciences i-CLeHS, Chimie ParisTech-PSL/CNRS, Paris 8060, France
| | - Anne Varenne
- Institute of Chemistry for Life and Health Sciences i-CLeHS, Chimie ParisTech-PSL/CNRS, Paris 8060, France
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO Brazil
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas 13084-971, São Paulo Brazil
| |
Collapse
|
9
|
Veloso WB, Paixão TR, Meloni GN. 3D printed electrodes design and voltammetric response. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2023]
|
10
|
Crapnell RD, Garcia-Miranda Ferrari A, Whittingham MJ, Sigley E, Hurst NJ, Keefe EM, Banks CE. Adjusting the Connection Length of Additively Manufactured Electrodes Changes the Electrochemical and Electroanalytical Performance. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22239521. [PMID: 36502222 PMCID: PMC9736051 DOI: 10.3390/s22239521] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 11/25/2022] [Accepted: 12/02/2022] [Indexed: 05/09/2023]
Abstract
Changing the connection length of an additively manufactured electrode (AME) has a significant impact on the electrochemical and electroanalytical response of the system. In the literature, many electrochemical platforms have been produced using additive manufacturing with great variations in how the AME itself is described. It is seen that when measuring the near-ideal outer-sphere redox probe hexaamineruthenium (III) chloride (RuHex), decreasing the AME connection length enhances the heterogeneous electrochemical transfer (HET) rate constant (k0) for the system. At slow scan rates, there is a clear change in the peak-to-peak separation (ΔEp) observed in the RuHex voltammograms, with the ΔEp shifting from 118 ± 5 mV to 291 ± 27 mV for the 10 and 100 mm electrodes, respectively. For the electroanalytical determination of dopamine, no significant difference is noticed at low concentrations between 10- and 100-mm connection length AMEs. However, at concentrations of 1 mM dopamine, the peak oxidation is shifted to significantly higher potentials as the AME connection length is increased, with a shift of 150 mV measured. It is recommended that in future work, all AME dimensions, not just the working electrode head size, is reported along with the resistance measured through electrochemical impedance spectroscopy to allow for appropriate comparisons with other reports in the literature. To produce the best additively manufactured electrochemical systems in the future, researchers should endeavor to use the shortest AME connection lengths that are viable for their designs.
Collapse
|
11
|
Additively manufactured electrodes for the electrochemical detection of hydroxychloroquine. Talanta 2022; 250:123727. [PMID: 35850056 PMCID: PMC9262657 DOI: 10.1016/j.talanta.2022.123727] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/27/2022] [Accepted: 07/04/2022] [Indexed: 11/21/2022]
Abstract
Although studies have demonstrated the inactivity of hydroxychloroquine (HCQ) towards SARS-CoV-2, this compound was one of the most prescribed by medical organizations for the treatment of hospitalized patients during the coronavirus pandemic. As a result of it, HCQ has been considered as a potential emerging contaminant in aquatic environments. In this context, we propose a complete electrochemical device comprising cell and working electrode fabricated by the additive manufacture (3D-printing) technology for HCQ monitoring. For this, a 3D-printed working electrode made of a conductive PLA containing carbon black assembled in a 3D-printed cell was associated with square wave voltammetry (SWV) for the fast and sensitive determination of HCQ. After a simple surface activation procedure, the proposed 3D-printed sensor showed a linear response towards HCQ detection (0.4-7.5 μmol L-1) with a limit of detection of 0.04 μmol L-1 and precision of 2.4% (n = 10). The applicability of this device was shown to the analysis of pharmaceutical and water samples. Recovery values between 99 and 112% were achieved for tap water samples and, in addition, the obtained concentration values for pharmaceutical tablets agreed with the values obtained by spectrophotometry (UV region) at a 95% confidence level. The proposed device combined with portable instrumentation is promising for on-site HCQ detection.
Collapse
|