Girel S, Meister I, Glauser G, Rudaz S. Hyphenation of microflow chromatography with electrospray ionization mass spectrometry for bioanalytical applications focusing on low molecular weight compounds: A tutorial review. MASS SPECTROMETRY REVIEWS 2024. [PMID: 38952056 DOI: 10.1002/mas.21898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 06/10/2024] [Accepted: 06/20/2024] [Indexed: 07/03/2024]
Abstract
Benefits of miniaturized chromatography with various detection modes, such as increased sensitivity, chromatographic efficiency, and speed, were recognized nearly 50 years ago. Over the past two decades, this approach has experienced rapid growth, driven by the emergence of mass spectrometry applications serving -omics sciences and the need for analyzing minute volumes of precious samples with ever higher sensitivity. While nanoscale liquid chromatography (flow rates <1 μL/min) has gained widespread recognition in proteomics, the adoption of microscale setups (flow rates ranging from 1 to 100 μL/min) for low molecular weight compound applications, including metabolomics, has been surprisingly slow, despite the inherent advantages of the approach. Highly heterogeneous matrices and chemical structures accompanied by a relative lack of options for both selective sample preparation and user-friendly equipment are usually reported as major hindrances. To facilitate the wider implementation of microscale analyses, we present here a comprehensive tutorial encompassing important theoretical and practical considerations. We provide fundamental principles in micro-chromatography and guide the reader through the main elements of a microflow workflow, from LC pumps to ionization devices. Finally, based on both our literature overview and experience, illustrated by some in-house data, we highlight the critical importance of the ionization source design and its careful optimization to achieve significant sensitivity improvement.
Collapse
Affiliation(s)
- Sergey Girel
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Isabel Meister
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| | - Gaetan Glauser
- Neuchâtel Platform of Analytical Chemistry, University of Neuchâtel, Neuchâtel, Switzerland
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
- Swiss Center of Applied Human Toxicology (SCAHT), Basel, Switzerland
| |
Collapse
|
2
|
Sedláčková S, Hubálek M, Vrkoslav V, Blechová M, Kozlík P, Cvačka J. Positive Effect of Acetylation on Proteomic Analysis Based on Liquid Chromatography with Atmospheric Pressure Chemical Ionization and Photoionization Mass Spectrometry. Molecules 2023; 28:molecules28093711. [PMID: 37175121 PMCID: PMC10180487 DOI: 10.3390/molecules28093711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/14/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023] Open
Abstract
A typical bottom-up proteomic workflow comprises sample digestion with trypsin, separation of the hydrolysate using reversed-phase HPLC, and detection of peptides via electrospray ionization (ESI) tandem mass spectrometry. Despite the advantages and wide usage of protein identification and quantification, the procedure has limitations. Some domains or parts of the proteins may remain inadequately described due to inefficient detection of certain peptides. This study presents an alternative approach based on sample acetylation and mass spectrometry with atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). These ionizations allowed for improved detection of acetylated peptides obtained via chymotrypsin or glutamyl peptidase I (Glu-C) digestion. APCI and APPI spectra of acetylated peptides often provided sequence information already at the full scan level, while fragmentation spectra of protonated molecules and sodium adducts were easy to interpret. As demonstrated for bovine serum albumin, acetylation improved proteomic analysis. Compared to ESI, gas-phase ionizations APCI and APPI made it possible to detect more peptides and provide better sequence coverages in most cases. Importantly, APCI and APPI detected many peptides which passed unnoticed in the ESI source. Therefore, analytical methods based on chymotrypsin or Glu-C digestion, acetylation, and APPI or APCI provide data complementary to classical bottom-up proteomics.
Collapse
Affiliation(s)
- Simona Sedláčková
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 12800 Prague, Czech Republic
| | - Martin Hubálek
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
| | - Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
| | - Miroslava Blechová
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
| | - Petr Kozlík
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 12800 Prague, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo Náměstí 542/2, 16000 Prague, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 2030/8, 12800 Prague, Czech Republic
| |
Collapse
|
3
|
Kloudová B, Strmeň T, Vrkoslav V, Chára Z, Pačes O, Cvačka J. Gas Dynamic Virtual Nozzle Sprayer for an Introduction of Liquid Samples in Atmospheric Pressure Ionization Mass Spectrometry. Anal Chem 2023; 95:4196-4203. [PMID: 36800482 PMCID: PMC10016749 DOI: 10.1021/acs.analchem.2c05349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Electrospray may exhibit inadequate ionization efficiency in some applications. In such cases, atmospheric-pressure chemical ionization (APCI) and photoionization (APPI) can be used. Despite a wide application potential, no APCI and APPI sources dedicated to very low sample flow rates exist on the market. Since the ion source performance depends on the transfer of analytes from the liquid to the gas phase, a nebulizer is a critical component of an ion source. Here, we report on the nebulizer with a gas dynamic virtual nozzle (GDVN) and its applicability in APCI at microliter-per-minute flow rates. Nebulizers differing by geometrical parameters were fabricated and characterized regarding the jet breakup regime, droplet size, droplet velocity, and spray angle for liquid flow rates of 0.75-15.0 μL/min. A micro-APCI source with the GDVN nebulizer behaved as a mass-flow-sensitive detector and provided stable and intense analyte signals. Compared to a classical APCI source, an order of magnitude lower detection limit for verapamil was achieved. Mass spectra recorded with the nebulizer in dripping and jetting modes were almost identical and did not differ from normal APCI spectra. Clogging never occurred during the experiments, indicating the high robustness of the nebulizer. Low-flow-rate APCI and APPI sources with a GDVN sprayer promise new applications for low- and medium-polar analytes.
Collapse
Affiliation(s)
- Barbora Kloudová
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10 Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43 Prague 2, Czech Republic
| | - Timotej Strmeň
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10 Prague 6, Czech Republic
| | - Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10 Prague 6, Czech Republic
| | - Zdeněk Chára
- Institute of Hydrodynamics of the Czech Academy of Sciences, Pod Pat'ankou 30/5, CZ-166 12 Prague 6, Czech Republic
| | - Ondřej Pačes
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10 Prague 6, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10 Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43 Prague 2, Czech Republic
| |
Collapse
|
4
|
Utility of Atmospheric-Pressure Chemical Ionization and Photoionization Mass Spectrometry in Bottom-Up Proteomics. SEPARATIONS 2022. [DOI: 10.3390/separations9020042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
In a typical bottom-up proteomics workflow, proteins are enzymatically cleaved, and the resulting peptides are analyzed by HPLC with electrospray ionization (ESI) tandem mass spectrometry. This approach is practical and widely applied. It has, however, limitations mostly related to less efficient or even inefficient ionization of some peptides in ESI sources. Gas-phase ionization methods like atmospheric-pressure chemical ionization (APCI) or atmospheric-pressure photoionization (APPI) offer alternative ways of detecting various analytes. This work is a systematic study of the ionization efficiencies of peptides in ESI, APCI, and APPI and the applicability of the mentioned ionizations in proteomics. A set of peptide standards and bovine serum albumin digests were examined using a high-resolution mass spectrometer coupled to an ultra HPLC system. Since the ionization efficiency in APCI and APPI depends strongly on experimental conditions, the ion source settings and mobile phase compositions were optimized for each ionization technique. As expected, tryptic peptides were best detected using ESI. The numbers of chymotrypsin peptides successfully detected by ESI, APPI, and APCI were comparable. In the case of Glu-C digest, APPI detected the highest number of peptides. The results suggest that gas-phase ionization techniques, particularly APPI, are an interesting alternative for detecting peptides and delivering complementary data in proteomics.
Collapse
|
5
|
Strmeň T, Vrkoslav V, Bosáková Z, Cvačka J. Atmospheric pressure chemical ionization mass spectrometry at low flow rates: Importance of ion source housing. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8722. [PMID: 31912928 DOI: 10.1002/rcm.8722] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/01/2019] [Accepted: 01/06/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE Hyphenation of atmospheric pressure chemical ionization (APCI) mass spectrometry with capillary and micro high-performance liquid chromatography (HPLC) is attractive for many applications, but reliable ion sources dedicated to these conditions are still missing. There are a number of aspects to consider when designing such an ion source, including the susceptibility of the ionization processes to ambient conditions. Here we discuss the importance of ion source housing for APCI at low flow rates. METHODS Selected compounds dissolved in various solvents were used to study ionization reactions at 10 μL/min flow rate. APCI spectra were generated using the Ion Max-S source (Thermo Fisher Scientific) operated with or without the ion source housing. RESULTS The APCI spectra of most compounds measured in the open and enclosed ion sources were markedly different. The differences were explained by water and oxygen molecules that entered the plasma region of the open ion source. Water tended to suppress charge transfer processes while oxygen diminished electron capture reactions and prevented the formation of acetonitrile-related radical cations useful for localizing double bonds in lipids. The effects associated with the ion source housing were significantly less important for compounds that are easy to protonate or deprotonate. CONCLUSIONS The use of ion source housing prevented alternative ionization channels leading to unwanted or unexpected ions. Compared with the conventional flow rate mode (1 mL/min), the effects of ambient air components were significantly higher at 10 μL/min, emphasizing the need for ion source housing in APCI sources dedicated to low flow rates.
Collapse
Affiliation(s)
- Timotej Strmeň
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| | - Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
| | - Zuzana Bosáková
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| |
Collapse
|
6
|
Vrkoslav V, Rumlová B, Strmeň T, Cvačka J. Temperature-programmed capillary high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometry for analysis of fatty acid methyl esters. J Sep Sci 2020; 43:2579-2588. [PMID: 32277790 DOI: 10.1002/jssc.201901235] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 04/07/2020] [Accepted: 04/07/2020] [Indexed: 11/10/2022]
Abstract
A new capillary high-performance liquid chromatography method with atmospheric pressure chemical ionization mass spectrometry was developed for the analysis of fatty acid methyl esters and long-chain alcohols. The chromatographic separation was achieved using a Zorbax SB-C18 HPLC column (0.3 × 150 mm, 3.5 μm) with a mobile phase composed of acetonitrile and formic acid and delivered isocratically at a flow rate of 10 μL/min. The column temperature was programmed simply, using a common column oven. Good reproducibility of the temperature profile and retention times were achieved. The temperature programming during the isocratic high-performance liquid chromatography run had a similar effect as a solvent gradient; it reduced retention times of later eluting analytes and improved their detection limits. Two atmospheric pressure chemical ionization sources of the mass spectrometry detector were compared: an enclosed conventional ion source and an in-house made ion source with a glass microchip nebulizer. The enclosed source provided better detectability of saturated fatty acid methyl esters and made it possible to determine the double bond positions using acetonitrile-related adducts, while the open chip-based source provided better analytical figures of merit for unsaturated fatty acid methyl esters. Temperature-programmed capillary high-performance liquid chromatography is a promising method for analyzing neutral lipids in lipidomics and other applications.
Collapse
Affiliation(s)
- Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic
| | - Barbora Rumlová
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Prague 2, Czech Republic
| | - Timotej Strmeň
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Prague 2, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Prague 2, Czech Republic
| |
Collapse
|