1
|
Orhan ZD, Ciğerim L. Evaluation of Effect of Different Insertion Speeds and Torques on Implant Placement Condition and Removal Torque in Polyurethane Dense D1 Bone Model. Polymers (Basel) 2024; 16:1361. [PMID: 38794554 PMCID: PMC11125928 DOI: 10.3390/polym16101361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/05/2024] [Accepted: 05/07/2024] [Indexed: 05/26/2024] Open
Abstract
The aim of this study was to evaluate the effect of two different insertion speeds at eight different insertion torque values ranging from 25 to 60 during implantation in a dense polyurethane (PU) D1 bone model on the placement condition and removal torque of dental implants. In this study, 50 pcf single-layer PU plates were used. In the study, a total of 320 implant sockets were divided into two groups, Group 1 (30 rpm) and Group 2 (50 rpm), in terms of insertion speed. Group 1 and Group 2 were divided into eight subgroups with 25, 30, 35, 40, 45, 50, 55 and 60 torques. There were 20 implant sockets in each subgroup. During the implantations, the implant placement condition and removal torque values were assessed. There was a statistically significant difference between the 30 and 50 rpm groups in terms of overall implant placement condition (p < 0.01). It was found that the removal torque values at 50 rpm were statistically significantly higher than those at 30 rpm (p < 0.01). This study showed that in dense D1 bone, the minimum parameters at which all implants could be placed at the bone level were 50 torque at 30 rpm and 40 torque at 50 rpm.
Collapse
Affiliation(s)
| | - Levent Ciğerim
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Van Yuzuncu Yil University, Van 65090, Turkey;
| |
Collapse
|
2
|
Ghambaryan N, Yessayan L, Hakobyan G. Long-term effectiveness of UV functionalised short (≤ 6 mm) dental implants placed in the posterior segments of the atrophied maxilla: controlled case series. Odontology 2024:10.1007/s10266-024-00926-0. [PMID: 38526626 DOI: 10.1007/s10266-024-00926-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 03/01/2024] [Indexed: 03/27/2024]
Abstract
This study evaluated long-term effectiveness UV functionalised short implants (≤ 6 mm) placed in the posterior segments of the atrophied maxilla. The study included 47 patients from 2018 to 2023 (aged 27 to 56 years, 24 women and 23 men) without any systemic diseases, with unilateral/bilateral missing teeth and vertical atrophy of the posterior maxillary area. Total installed were 64 short UV-functionalized implants and 62 standard implants over 10 mm in length in segments maxilla with sufficient bone parameters. Clinical, laboratory and cone beam computed tomography (CBCT) methods were used to plan implant therapy. The clinical indices included the following parameters: ISQ, MBL, OHIP-G scale. For short implants, the median ISQ at placement was 62.2 for primary stability and the median ISQ at 5 months was 69.6 ISQ. For standard implant, the mean ISQ at placement was 64.3 ISQ, and ISQ after 5 months was 71.6 ISQ. After 6 months mean MBL short implants 0.87 mm, after 1 year 1.13 mm, after 5 years was 1.48 mm. After 6 months mean MBL standard implants 0.84 mm, after 1 year 1.24 mm, after 5 years was 1.58 mm. Mean OHIP-G scores-patients satisfaction with the implant at 4.8 ± 0.3, satisfaction with the operation 4.6 ± 0.4; satisfaction with prosthetics 4.7 ± 0.5. Cumulative success rate 5 years short implants was 96.7%, standard implants was 97.4%, and prosthesis cumulative survival rate was 97.2%. Short ultraviolet functionalized implants used in the posterior resorbed segment of maxilla have been shown to be a reliable alternative to sinus lift, demonstrating fewer complications, reduction in the number of additional surgical interventions and showed satisfactory long-term survival.
Collapse
Affiliation(s)
- Naira Ghambaryan
- Department of Surgical Stomatology and Maxillofacial Surgery, Yerevan State Medical University After M. Heratsi, Yerevan, Armenia
| | - Lazar Yessayan
- Department of Therapeutic Stomatology, Yerevan State Medical University. M. Heratsi, Yerevan, Armenia
| | - Gagik Hakobyan
- Department of Surgical Stomatology and Maxillofacial Surgery, Yerevan State Medical University After M. Heratsi, Yerevan, Armenia.
| |
Collapse
|
3
|
In-Vitro Biofilm Removal Efficacy Using Water Jet in Combination with Cold Plasma Technology on Dental Titanium Implants. Int J Mol Sci 2023; 24:ijms24021606. [PMID: 36675120 PMCID: PMC9867126 DOI: 10.3390/ijms24021606] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/22/2022] [Accepted: 12/29/2022] [Indexed: 01/15/2023] Open
Abstract
Peri-implantitis-associated inflammation can lead to bone loss and implant failure. Current decontamination measures are ineffective due to the implants' complex geometry and rough surfaces providing niches for microbial biofilms. A modified water jet system (WaterJet) was combined with cold plasma technology (CAP) to achieve superior antimicrobial efficacy compared to cotton gauze treatment. Seven-day-old multi-species-contaminated titanium discs and implants were investigated as model systems. The efficacy of decontamination on implants was determined by rolling the implants over agar and determining colony-forming units supported by scanning electron microscopy image quantification of implant surface features. The inflammatory consequences of mono and combination treatments were investigated with peripheral blood mononuclear cell surface marker expression and chemokine and cytokine release profiles on titanium discs. In addition, titanium discs were assayed using fluorescence microscopy. Cotton gauze was inferior to WaterJet treatment according to all types of analysis. In combination with the antimicrobial effect of CAP, decontamination was improved accordingly. Mono and CAP-combined treatment on titanium surfaces alone did not unleash inflammation. Simultaneously, chemokine and cytokine release was dramatically reduced in samples that had benefited from additional antimicrobial effects through CAP. The combined treatment with WaterJet and CAP potently removed biofilm and disinfected rough titanium implant surfaces. At the same time, non-favorable rendering of the surface structure or its pro-inflammatory potential through CAP was not observed.
Collapse
|
4
|
Clinical Effects of Photofunctionalization on Implant Stability and Marginal Bone Loss: Systematic Review and Meta-Analysis. J Clin Med 2022; 11:jcm11237042. [PMID: 36498616 PMCID: PMC9739233 DOI: 10.3390/jcm11237042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 11/20/2022] [Accepted: 11/24/2022] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Several clinical trials have recently been conducted to elucidate the effectiveness of photofunctionalization. The aim of this review was to systematically analyze the clinical effects of photofunctionalization on implant stability and marginal bone loss (MBL). METHODS An electronic search in four databases and a manual search were conducted in September 2022. Randomized controlled trials (RCTs), clinical controlled trials (CCTs), and cohort and case-control studies evaluating the effects of photofunctionalization on implant stability or marginal bone loss (MBL) in humans were included. The methodological quality assessment using RoB 2.0 and the ROBINS-I tool was performed based on different study designs. RESULTS Seven studies were included for a qualitative analysis, and five of them were chosen for a meta-analysis. The meta-analysis revealed that photofunctionalization significantly improved the stability of the implant 2 months after implantation (p = 0.04; MD = 3.48; 95% CI = -0.23 to 6.73) and increased the osseointegration speed index (OSI) (p = 0.007; MD = 2.13; 95% CI = 0.57 to 3.68). However, no significant improvements of implant stability were observed 2 weeks (p = 0.62), 4 weeks (p = 0.31), nor 4 months (p = 0.24) after implantation. The evaluation presented no significant reductions in MBL. CONCLUSIONS Based on the positive effect of photofunctionalization on the rate of establishing implant stability, photofunctionalization may provide an effective and practical strategy to achieve faster osseointegration and reduce the overall healing time. Photofunctionalization appears to improve the implant stability. However, the clinical effect of photofunctionalization on MBL remains unclear due to the shortage of available studies.
Collapse
|
5
|
Abstract
Surface characteristics are an important factor for long-term clinical success of dental implants. Alterations of implant surface characteristics accelerate or improve osseointegration by interacting with the physiology of bone healing. Dental implant surfaces have been traditionally modified at the microlevel. Recently, researchers have actively investigated nano-modifications in dental implants. This review explores implant surface modifications that enhance biological response at the interface between a bone and the implant.
Collapse
Affiliation(s)
- In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101 Daehak-Ro, Jongro-Gu, Seoul 03080, Korea.
| |
Collapse
|
6
|
Chang LC. Clinical Applications of Photofunctionalization on Dental Implant Surfaces: A Narrative Review. J Clin Med 2022; 11:jcm11195823. [PMID: 36233693 PMCID: PMC9571244 DOI: 10.3390/jcm11195823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 09/23/2022] [Accepted: 09/27/2022] [Indexed: 11/06/2022] Open
Abstract
Dental implant therapy is a common clinical procedure for the restoration of missing teeth. Many methods have been used to promote osseointegration for successful implant therapy, including photofunctionalization (PhF), which is defined as the modification of titanium surfaces after ultraviolet treatment. It includes the alteration of the physicochemical properties and the enhancement of biological capabilities, which can alter the surface wettability and eliminate hydrocarbons from the implant surface by a biological aging process. PhF can also enhance cellular migration, attachment, and proliferation, thereby promoting osseointegration and coronal soft tissue seal. However, PhF did not overcome the dental implant challenge of oral cancer cases. It is necessary to have more clinical trials focused on complex implant cases and non-dental fields in the future.
Collapse
Affiliation(s)
- Li-Ching Chang
- Department of Dentistry, Chang Gung Memorial Hospital, Chiayi 61363, Taiwan;
- Institute of Nursing and Department of Nursing, Chang Gung University of Science and Technology, Chiayi 61363, Taiwan
| |
Collapse
|
7
|
Improvement in Osseointegration of Titanium Dental Implants after Exposure to Ultraviolet-C Light for Various Times: an Experimental Study in Beagle Dogs. J Oral Maxillofac Surg 2022; 80:1389-1397. [DOI: 10.1016/j.joms.2022.04.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/10/2022] [Accepted: 04/23/2022] [Indexed: 12/11/2022]
|
8
|
Choi B, Lee YC, Oh KC, Lee JH. Effects of photofunctionalization on early osseointegration of titanium dental implants in the maxillary posterior region: a randomized double-blinded clinical trial. Int J Implant Dent 2021; 7:37. [PMID: 33969450 PMCID: PMC8107060 DOI: 10.1186/s40729-021-00318-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 03/12/2021] [Indexed: 11/10/2022] Open
Abstract
Background This study aimed to investigate the effects of ultraviolet (UV) photofunctionalization on the stability of implants during the early phase in the posterior region of the maxilla. The study was a randomized double-blinded clinical trial. Half of the participants received conventional commercial implants while the other half received UV-irradiated implants. The surgical sites were classified into three bone quality groups (II, III, IV) based on the grayscale value measured on cone-beam computed tomography. The values obtained from resonance frequency analysis were recorded immediately after implant placement and at 4 weeks and at 4 months postoperatively. The marginal bone level of the implants was evaluated using periapical radiographs at 4 weeks, 4 months, and 1 year postoperatively. Results Fifty-seven implants placed in 34 participants were analyzed in this study. In group III, significant differences were observed in terms of the differences of resonance frequency analysis values at 4 weeks (p = 0.004) and 4 months (p = 0.017) postoperatively. In group II, the UV-treated group showed significantly lesser bone loss at 4 weeks post-operatively (p = 0.037). Conclusions Within the limitation of the present study, we concluded that UV surface treatment on implants may increase the initial stability in the region of the maxilla with poor bone quality.
Collapse
Affiliation(s)
- Bada Choi
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, 03722, Korea
| | - Ye Chan Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, 03722, Korea
| | - Kyung Chul Oh
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, 03722, Korea
| | - Jae Hoon Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, 03722, Korea.
| |
Collapse
|
9
|
Pesce P, Menini M, Santori G, Giovanni ED, Bagnasco F, Canullo L. Photo and Plasma Activation of Dental Implant Titanium Surfaces. A Systematic Review with Meta-Analysis of Pre-Clinical Studies. J Clin Med 2020; 9:jcm9092817. [PMID: 32878146 PMCID: PMC7565759 DOI: 10.3390/jcm9092817] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/26/2020] [Accepted: 08/27/2020] [Indexed: 02/07/2023] Open
Abstract
Background: Ultraviolet (UV) and non-thermal plasma functionalization are surface treatment modalities that seem able to improve osseointegration. The aim of this systematic review and meta-analysis is to assess the effect of the two methods and possible differences. Materials and Methods: The systematic research of pre-clinical animal studies was conducted up to May 2020 in the databases PubMed/Medline, Scopus and the Cochrane Lybrary. A meta-analysis was performed by using the DerSimonian–Laird estimator in random-effects models. Results: Through the digital search, 518 articles were identified; after duplicate removal and screening process 10 papers were included. Four studies evaluating UV treatment in rabbits were included in the meta-analysis. The qualitative evaluation of the included studies showed that both UV photofunctionalization and non-thermal plasma argon functionalization of titanium implant surfaces might be effective in vivo to improve the osseointegration. The meta-analysis on four studies evaluating UV treatment in rabbits showed that bone to implant contact values (expressed as standardized mean differences and raw mean differences) were significantly increased in the bio-activated groups when follow-up times were relatively homogeneous, although a high heterogeneity (I2 > 75%) was found in all models. Conclusions: The present systematic review and meta-analysis on pre-clinical studies demonstrated that chair-side treatment of implants with UV or non-thermal plasma appear to be effective for improving osseointegration. This systematic review supports further clinical trials on this topic.
Collapse
Affiliation(s)
- Paolo Pesce
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, 16132 Genoa, Italy; (P.P.); (M.M.); (G.S.); (E.D.G.); (F.B.)
| | - Maria Menini
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, 16132 Genoa, Italy; (P.P.); (M.M.); (G.S.); (E.D.G.); (F.B.)
| | - Gregorio Santori
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, 16132 Genoa, Italy; (P.P.); (M.M.); (G.S.); (E.D.G.); (F.B.)
| | - Emanuele De Giovanni
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, 16132 Genoa, Italy; (P.P.); (M.M.); (G.S.); (E.D.G.); (F.B.)
| | - Francesco Bagnasco
- Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, 16132 Genoa, Italy; (P.P.); (M.M.); (G.S.); (E.D.G.); (F.B.)
| | - Luigi Canullo
- Private Practice, Via Nizza, 46, 00198 Rome, Italy
- Correspondence: ; Tel.: +39-347-6201-976
| |
Collapse
|
10
|
Arya G, Kumar V. Evaluation of osseintegration between traditional and modified hydrophilic titanium dental implants - Systematic analysis. Natl J Maxillofac Surg 2020; 11:176-181. [PMID: 33897177 PMCID: PMC8051648 DOI: 10.4103/njms.njms_44_20] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/19/2020] [Accepted: 07/04/2020] [Indexed: 11/16/2022] Open
Abstract
The aim of the study was to conduct a systematic review to access the osseointegration between traditional and modified Hydrophilic Titanium Dental Implants for period of 10 years. PUBMed articles were searched from last ten years up to 15/12/2019 from which 24 studies included in this review. This systematic review compiles the data about osseintegration in hydrophilic titanium implants in human trials. It sheds light on the mechanism of integration of hydrophilic surfaces and numeric data to support the purpose of the review.
Collapse
Affiliation(s)
- Geeta Arya
- Department of Prosthodontics and Oral Implantology, Seema Dental College and Hospital, Rishikesh, Uttarakhand, India
| | - Varun Kumar
- Department of Prosthodontics and Oral Implantology, Seema Dental College and Hospital, Rishikesh, Uttarakhand, India
| |
Collapse
|
11
|
UV-Pre-Treated and Protein-Adsorbed Titanium Implants Exhibit Enhanced Osteoconductivity. Int J Mol Sci 2020; 21:ijms21124194. [PMID: 32545509 PMCID: PMC7349557 DOI: 10.3390/ijms21124194] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Accepted: 06/10/2020] [Indexed: 12/18/2022] Open
Abstract
Titanium materials are essential treatment modalities in the medical field and serve as a tissue engineering scaffold and coating material for medical devices. Thus, there is a significant demand to improve the bioactivity of titanium for therapeutic and experimental purposes. We showed that ultraviolet light (UV)-pre-treatment changed the protein-adsorption ability and subsequent osteoconductivity of titanium. Fibronectin (FN) adsorption on UV-treated titanium was 20% and 30% greater after 1-min and 1-h incubation, respectively, than that of control titanium. After 3-h incubation, FN adsorption on UV-treated titanium remained 30% higher than that on the control. Osteoblasts were cultured on titanium disks after 1-h FN adsorption with or without UV-pre-treatment and on titanium disks without FN adsorption. The number of attached osteoblasts during the early stage of culture was 80% greater on UV-treated and FN-adsorbed (UV/FN) titanium than on FN-adsorbed (FN) titanium; osteoblasts attachment on UV/FN titanium was 2.6- and 2.1-fold greater than that on control- and UV-treated titanium, respectively. The alkaline phosphatase activity of osteoblasts on UV/FN titanium was increased 1.8-, 1.8-, and 2.4-fold compared with that on FN-adsorbed, UV-treated, and control titanium, respectively. The UV/FN implants exhibited 25% and 150% greater in vivo biomechanical strength of bone integration than the FN- and control implants, respectively. Bone morphogenetic protein-2 (BMP-2) adsorption on UV-treated titanium was 4.5-fold greater than that on control titanium after 1-min incubation, resulting in a 4-fold increase in osteoblast attachment. Thus, UV-pre-treatment of titanium accelerated its protein adsorptivity and osteoconductivity, providing a novel strategy for enhancing its bioactivity.
Collapse
|