1
|
Makkeyah F, Elsahn NA, Bakr MM, Al Ankily M. Effect of Acidic Media on Surface Topography and Color Stability of Two Different Glass Ceramics. Eur J Dent 2024. [PMID: 38776980 DOI: 10.1055/s-0044-1786842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2024] Open
Abstract
OBJECTIVE The aim of this study was to determine the effect of two acidic beverages (orange juice and H3PO4-containing fizzy drink) on the surface topography and color stability of two commonly used computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic materials. MATERIALS AND METHODS Sixty samples of two CAD/CAM ceramic materials, lithium disilicate (IPS e-max CAD) and zirconia reinforced lithium silicate (Vita Suprinity), were prepared according to the manufacturer's instructions. The samples were immersed in one of three media (artificial saliva, orange juice and H3PO4-containing fizzy drink) and then stored in an incubator at 37 °C for 24 hours). Before and after immersion in different media, the surface roughness (Ra) of the samples was assessed using profilometer (JITAI8101 Surface Roughness Tester-Beijing Jitai Tech Detection Device Co. Ltd, China) and the color parameters were measured using VITA Easyshade Advance 4.01 (VITA shade, VITA made, VITA). Surface topography was observed using scanning electron microscope (SEM) and surface mineral content was compared before and after immersion. Paired sample t-test was used to determine the change in Ra before and after immersion. Two-way analysis of variance was used to determine the effect of different CAD/CAM materials and immersion media on the mean ∆Ra and mean ∆E of the studied groups. Tukey's honest significant difference posthoc test was used for multiple comparisons at a level of significance (α = 0.05). RESULTS A significant increase in Ra and a decrease in the color stability of the two investigated ceramic materials were detected after immersion in the acidic media than in artificial saliva. SEM and energy-dispersive X-ray results revealed the dissolution of the glassy matrix and the exposure of silicate crystals. CONCLUSION The surface topography and color stability of glass ceramics are affected by the pH of different acidic media.
Collapse
Affiliation(s)
- Fatma Makkeyah
- Fixed Prosthodontics Department, Faculty of Dentistry, The British University in Egypt, Cairo, Egypt
| | - Nesrine A Elsahn
- Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates
- Center of Medical and Bio-allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
- Department of Operative Dentistry, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Mahmoud M Bakr
- General Dental Practice, School of Medicine and Dentistry, Griffith University, Gold Coast, Queensland, Australia
| | - Mahmoud Al Ankily
- Oral Biology Department, Faculty of Dentistry, The British University in Egypt, Cairo, Egypt
| |
Collapse
|
2
|
Sakae LO, Kairalla CA, Viana ÍEL, Carvalho TS, Niemeyer SH, Hara AT, Scaramucci T. Characteristics of tin-containing fluoride toothpastes related to erosive tooth wear protection. J Dent 2024; 143:104901. [PMID: 38417610 DOI: 10.1016/j.jdent.2024.104901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Revised: 02/22/2024] [Accepted: 02/24/2024] [Indexed: 03/01/2024] Open
Abstract
OBJECTIVES To assess the effect of different tin-containing toothpastes on the control of erosive tooth wear in enamel and dentin. METHODS Enamel and dentin slabs were randomly distributed into 7 experimental groups (n = 10/substrate): C-: negative control (Artificial saliva); AmF (regular fluoridated toothpaste without tin); Sn-1 (SnF2/NaF); Sn-2 (SnF2/NaF/SnCl2); Sn-3 (SnCl2/NaF); Sn-4 (SnF2/SnCl2); Sn-5 (SnCl2/AmF/NaF/chitosan). Specimens were submitted to 5-day erosion-abrasion cycling. Surface loss (SL) was determined with an optical profilometer. Tin deposition on the tooth surfaces and some characteristics of the toothpastes (pH, potentially available F-, %weight of solid particles, and RDA) were also assessed. Data were statistically analyzed (α = 0.05). RESULTS For enamel, the Sn-2 presented the lowest SL, not differing significantly from AmF, C+, and Sn-3. The SL of these groups was significantly lower than the C-, except for Sn-3. Sn-1 and Sn-4 were also not significantly different from C-. For dentin, C- significantly showed the highest SL values, whilst, Sn-1 presented the lowest SL, not differing significantly from AmF, Sn-2, C+, and Sn-3. There was a significant positive association between enamel SL and the pH and tin deposition. Dentin SL was significantly negatively associated with the %weight of solid particles and RDA. CONCLUSIONS Most of the tin-toothpastes were able to exhibit some protection against ETW. In this process, the toothpastes characteristics play a role, as lower enamel SL was significantly associated with lower pH values and tin deposition; and lower dentin SL was associated with higher %weight of solid particles and RDA of the toothpastes. CLINICAL SIGNIFICANCE Tin-containing toothpastes can be used for erosive tooth wear protection, but our study showed that their effect depends on the pH, amount of tin deposition, % weight of solid particles and RDA of the toohpastes.
Collapse
Affiliation(s)
- Letícia Oba Sakae
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP 05508-000, Brazil
| | - Cláudia Allegrini Kairalla
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP 05508-000, Brazil
| | - Ítallo Emídio Lira Viana
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP 05508-000, Brazil; Department of Comprehensive Care, Division of Operative Dentistry, Tufts University School of Dental Medicine, 1 Kneeland Street, Boston, MA 02111, USA
| | - Thiago Saads Carvalho
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, CH-3010 Bern, Switzerland
| | - Samira Helena Niemeyer
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, CH-3010 Bern, Switzerland
| | - Anderson Takeo Hara
- Department of Cariology, Operative Dentistry and Dental Public Health, Oral Health Research Institute, Indiana University School of Dentistry, 415 Lansing Street, Indianapolis, IN 46202, USA
| | - Taís Scaramucci
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP 05508-000, Brazil.
| |
Collapse
|
3
|
Chalkidis J, Barke S, Rohland B, Schmidt A, Kanzow P, Wiegand A. In vitro study on the preventive effect of children's toothpastes on erosive tooth wear of primary bovine enamel and dentin. Sci Rep 2023; 13:10884. [PMID: 37407760 DOI: 10.1038/s41598-023-38043-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 07/01/2023] [Indexed: 07/07/2023] Open
Abstract
This in vitro study aimed to analyse the effect of various children's toothpastes on erosive tooth wear of primary bovine enamel and dentin. Enamel and dentin specimens (n = 12) were cyclically eroded (6 × 60 s/d, citric acid, pH 2.4) and brushed (2 × 15 s/d, 2 N) over 5 days. Nine fluoride toothpastes (500 to 1450 ppm) and eight toothpastes containing no fluoride or other active ingredients (hydroxyapatite and/or xylitol) were tested. Unbrushed specimens served as control. Tissue loss was quantified using widefield confocal microscopy and statistically analysed using two-way and one-way ANOVAs followed by Scheffe's (enamel) or Tamhane's (dentin) post-hoc tests (p < 0.05). Only one fluoride toothpaste (1400 ppm) was able to reduce erosive wear of enamel significantly by 15% compared to the control (padj. = 0.002). All fluoridated toothpastes reduced dentin surface loss significantly by 32 to 69% compared to the control (padj. ≤ 0.001), while fluoride-free toothpastes were unable to reduce dentin loss significantly (padj. ≥ 0.971). Most fluoridated toothpastes caused less erosive wear compared to fluoride-free toothpastes. Children toothpastes containing fluoride were more effective in reducing erosive wear compared to toothpastes containing no fluoride or other active ingredients.
Collapse
Affiliation(s)
- Jennifer Chalkidis
- Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Sarah Barke
- Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Bianca Rohland
- Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Alexandra Schmidt
- Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Philipp Kanzow
- Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Annette Wiegand
- Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
| |
Collapse
|
4
|
Sakae LO, Renzo ALM, Viana ÍEL, Niemeyer SH, Carvalho TS, Scaramucci T. Impact of different brushing/abrasion protocols on erosive tooth wear for in vitro studies. Arch Oral Biol 2023; 148:105657. [PMID: 36827929 DOI: 10.1016/j.archoralbio.2023.105657] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 01/16/2023] [Accepted: 02/18/2023] [Indexed: 02/22/2023]
Abstract
OBJECTIVE To investigate the influence of different toothbrushing (with dentifrice) protocols on the progression of erosive tooth wear for in vitro studies. DESIGN Bovine enamel specimens were randomly distributed into 12 experimental groups (n = 10), according to the study factors: (1) brushing movement (horizontal or circular); (2) slurry diluent (artificial saliva or distilled water); (3) toothpaste dilution ratio (1:2, 1:3 or 1:4). A 5-day erosion-abrasion cycling model was performed, each consisting of 4 erosive challenges (0.3 % citric acid, pH=2.6) followed by 60 min exposure to artificial saliva. Brushing with fluoride toothpaste (15 s, 1400 ppm F-, AmF) was carried out 2x/day. Enamel surface loss (SL) was determined by optical profilometry. Data were statistically analyzed with three-way ANOVA and Tukey tests (α = 0.05). RESULTS SL was lower for the horizontal movement than for the circular (p = 0.044). There were no significant differences among the dilution ratios for artificial saliva. For distilled water, the more concentrated slurry (1:2) presented greater surface loss than the less concentrated slurries (1:3 and 1:4, p = 0.049 and p = 0.014, respectively). Dilutions with artificial saliva at ratios 1:3 and 1:4 presented higher surface loss than with distilled water (p = 0.008 and p < 0.001, respectively); however, for 1:2 ratio, there were no significant differences between the diluents. CONCLUSIONS The in vitro progression of enamel SL was influenced by the brushing movement, as well as the combination of the dilution ratio and the diluent of the toothpaste slurry, and therefore, all these factors must be considered when comparing results from different studies.
Collapse
Affiliation(s)
- Letícia Oba Sakae
- Department of Restorative Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, Cidade Universitária, 05508-000 São Paulo, SP, Brazil.
| | - Ana Luísa Meira Renzo
- Department of Restorative Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, Cidade Universitária, 05508-000 São Paulo, SP, Brazil.
| | - Ítallo Emídio Lira Viana
- Department of Restorative Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, Cidade Universitária, 05508-000 São Paulo, SP, Brazil.
| | - Samira Helena Niemeyer
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, CH-3010 Bern, Switzerland.
| | - Thiago Saads Carvalho
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 3, CH-3010 Bern, Switzerland.
| | - Taís Scaramucci
- Department of Restorative Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, Cidade Universitária, 05508-000 São Paulo, SP, Brazil.
| |
Collapse
|
5
|
Elraggal A, R Afifi R, Alamoush RA, Raheem IA, Watts DC. Effect of acidic media on flexural strength and fatigue of CAD-CAM dental materials. Dent Mater 2023; 39:57-69. [PMID: 36496258 DOI: 10.1016/j.dental.2022.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 11/13/2022] [Accepted: 11/25/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To investigate the effect of acidic media, including beverages and gastric fluids on flexural strength and fatigue of CAD-CAM materials. METHODS Four CAD-CAM materials (high-translucency zirconia (Ceramill Zolid HT+), lithium disilicate (IPS e-max CAD), hybrid ceramic (Vita Enamic), and nanohybrid resin composite (Grandio Blocs) were prepared and immersed in one of five media (gastric HCl, white wine, Coca-Cola, orange juice, and artificial saliva) in an incubator (37 ℃, 24 h). Surface topography and roughness were obtained using a scanning electron microscope (SEM) and a stylus contact profilometer, respectively. Initial 3-point flexural strength was measured for half of the bars (n = 20/gp) using a universal testing machine (0.5 mm/min). The other bars underwent 106 cyclic fatigue loadings before measurement of residual 3-point flexural strength. Data were statistically analyzed (two-way and three-way ANOVA, Tukey's post-hoc, p < 0.05). Weibull distributions were plotted for reliability analysis. RESULTS Zirconia bars has the highest initial flexural strengths followed by lithium disilicate, while resin composite and hybrid ceramic groups had the lowest strength regardless of the erosive medium. Cyclic fatigue significantly reduced initial flexural strengths for all materials except for hybrid ceramic and resin composite. Weibull moduli were the highest for zirconia, lithium disilicate and resin composite and lowest for hybrid ceramic. SIGNIFICANCE Erosive media significantly changed surface roughness of CAD-CAM materials except for zirconia and resin composite without jeopardizing the flexural strength of the CAD-CAM materials. Despite the higher flexural strengths for zirconia and lithium disilicate, resin composite and hybrid ceramic were more resistant to cyclic fatigue.
Collapse
Affiliation(s)
- Alaaeldin Elraggal
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Rania R Afifi
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Rasha A Alamoush
- Department of Prosthodontics, School of Dentistry, The University of Jordan, Amman, Jordan
| | - Islam Abdel Raheem
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - David C Watts
- School of Medical Sciences, University of Manchester, Manchester, UK
| |
Collapse
|
6
|
Wang Q, Luan J, Zhao Z, Kong W, Zhang C, Ding J. Dentin-desensitizing biomaterials. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2022.108060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
7
|
Viana ÍEL, Borges R, Marchi J, Feitosa S, Marques MM, Scaramucci T. A 58S bioactive glass for dentin hypersensitivity and erosive tooth wear: An in vitro study. J Dent 2022; 127:104343. [PMID: 36270541 DOI: 10.1016/j.jdent.2022.104343] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 10/04/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVES To assess the effect of an experimental 58S bioactive glass on dentin permeability (dP) and erosive tooth wear (dentin surface loss - dSL). METHODS 58S bioactive glass was synthetized using a sol-gel methodology, following by lyophilization and calcination, then mixed with phosphoric acid to obtain a paste (BGP). Forty-eight dentin disks (1 mm-thick) were used for dP, and 48 dentin slabs (3 mm × 3 mm) for dSL, which were assessed at three time intervals: post-EDTA (5 min in 17% EDTA solution); post-treatment (C: distilled water; BGP: experimental bioactive glass paste; NP: Nupro prophylaxis paste; CXT: Clinpro XT varnish); and post-erosive/abrasive cycling. Data were statistically analyzed (α=0.05). RESULTS For dP and dSL, Groups did not differ significantly post-EDTA (p>0.05). Post-treatment, all groups showed lower dP than C (p<0.05), without differing significantly among them. For the dSL analysis, Groups C, BGP and NP did not differ significantly, showing lower values than CXT (p<0.05). Post-cycling, C continued to show the highest dP (p<0.05). Specimens from Group CXT had the lowest dP and did not differ from NP (p=0.86) which did not differ from BGP (p=0.193). For C and BGP, dP value was higher post-cycling than post-treatment (p<0.05). For NP and CXT, these experimental times did not differ (p>0.05). Post-cycling, dSL for C, BGP and NP did not differ significantly; values were higher than those for CXT (p<0.05). CONCLUSIONS BGP reduced dP after application, with a reduced effect after cycling. Nonetheless, it was not able to protect dentin against erosive tooth wear. CLINICAL SIGNIFICANCE Minimizing dentin hypersensitivity is a challenge in the field of dentistry. The development of alternative products with potential to obliterate dentinal tubules and provide resistance to chemical/mechanical stimuli is, thus, highly desirable. We have proposed a material able to reduce dentin permeability, which has emerged as a promising alternative for this purpose.
Collapse
Affiliation(s)
- Ítallo Emídio Lira Viana
- Department of Restorative Dentistry, School of Dentistry, University of Sao Paulo, 2227 Professor Lineu Prestes Avenue, São Paulo, SP 05508-000, Brazil
| | - Roger Borges
- Center for Natural Sciences and Humanities, Federal University of ABC, Santo André, SP, Brazil
| | - Juliana Marchi
- Center for Natural Sciences and Humanities, Federal University of ABC, Santo André, SP, Brazil
| | - Sabrina Feitosa
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, IN, USA
| | - Márcia Martins Marques
- Post-Graduation Program, School of Dentistry, Universidade Ibirapuera, São Paulo, SP, Brazil
| | - Taís Scaramucci
- Department of Restorative Dentistry, School of Dentistry, University of Sao Paulo, 2227 Professor Lineu Prestes Avenue, São Paulo, SP 05508-000, Brazil.
| |
Collapse
|
8
|
Né YGDS, Souza-Monteiro D, Frazão DR, Alvarenga MOP, Aragão WAB, Fagundes NF, de Souza-Rodrigues RD, Lima RR. Treatment for dental erosion: a systematic review of in vitro studies. PeerJ 2022; 10:e13864. [PMID: 36389398 PMCID: PMC9651041 DOI: 10.7717/peerj.13864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 07/18/2022] [Indexed: 11/11/2022] Open
Abstract
Background Dental erosion is a chemical loss of the mineralized dental tissue caused by exposure to nonbacterial acids. Different treatment protocols have been adopted with the use of fluoride compounds to promote the formation of a layer of mineral precipitation in eroded lesions. Aim This systematic review aimed to evaluate the main treatments for dental erosion. Methodology This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and recorded in the Open Science Framework database (OSF) under DOI 10.17605/OSF.IO/XMFNZ. The searches were conducted in six electronic databases (Pubmed, Embase, Web of Science, Cochrane, Scopus, Lilacs) and two grey literature sources (Google Scholar and OpenGrey). The eligibility criteria included in vitro studies that evaluated eroded teeth under treatment with some topical agent. Risk of bias assessment and qualitative synthesis were performed using the Cochrane collaboration's tool for assessing risk of bias modified for in vitro studies. Results A total of 522 studies were identified, and only four studies that fulfilled our eligibility criteria were included in this review. Among these studies, three were considered to have a low risk of bias, and one to have a high risk of bias. Two studies evaluated the anti-erosion effect of fluoride toothpaste, and the other two assessed the action of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) on the surface of human teeth. Among the products analyzed, CPP-ACP was the only one that promoted a significant increase in enamel microhardness and reduced tooth wear. Conclusion Based on the in vitro studies included in this review, there was no anti-erosion effect after using different fluoride toothpaste. However, it should be considered that one of these studies presented a high risk of bias. On the other hand, studies with CPP-ACP showed anti-erosion efficacy when applied before or after erosive wear.
Collapse
Affiliation(s)
- Yago Gecy de Sousa Né
- Laboratory of Functional and Structural Biology, Institute of Biological Sciences, Federal University of Pará, Belém, Pará, Brazil
| | - Deiweson Souza-Monteiro
- Laboratory of Functional and Structural Biology, Institute of Biological Sciences, Federal University of Pará, Belém, Pará, Brazil
| | - Deborah Ribeiro Frazão
- Laboratory of Functional and Structural Biology, Institute of Biological Sciences, Federal University of Pará, Belém, Pará, Brazil
| | - María Olimpia Paz Alvarenga
- Laboratory of Functional and Structural Biology, Institute of Biological Sciences, Federal University of Pará, Belém, Pará, Brazil
| | - Walessa Alana Bragança Aragão
- Laboratory of Functional and Structural Biology, Institute of Biological Sciences, Federal University of Pará, Belém, Pará, Brazil
| | | | - Renata Duarte de Souza-Rodrigues
- Laboratory of Functional and Structural Biology, Institute of Biological Sciences, Federal University of Pará, Belém, Pará, Brazil
| | - Rafael Rodrigues Lima
- Laboratory of Functional and Structural Biology, Institute of Biological Sciences, Federal University of Pará, Belém, Pará, Brazil
| |
Collapse
|
9
|
Elraggal A, Afifi R, Abdelraheem I. Effect of erosive media on microhardness and fracture toughness of CAD-CAM dental materials. BMC Oral Health 2022; 22:191. [PMID: 35590294 PMCID: PMC9118722 DOI: 10.1186/s12903-022-02230-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 05/09/2022] [Indexed: 11/10/2022] Open
Abstract
Background Erosive acids might create surface flaws and deteriorate the mechanical properties of CAD-CAM materials. This invitro study aimed to investigate the effect of simulated gastric HCl and extrinsic erosive acids on surface microhardness and fracture toughness of CAD-CAM materials. Methods 400 bar-shaped specimens (17×4×2 mm3) were prepared from 4 different CAD-CAM dental materials (n = 100/group); monolithic zirconia (Ceramill Zolid HT+, Amanngirbach, Austria), lithium disilicate ceramic (IPS e.max CAD, Ivoclar Vivadent, Liechtenstein), nanohybrid resin composite (Grandio Blocs, VOCO) and polymer-infiltrated glass network (Vita Enamic, VITA Zahnfabrik). Specimens from each material type were further subdivided into 5 groups (n = 20) according to the erosive media applied (simulated gastric HCl, white wine, Coca-Cola®, orange juice, and artificial saliva that served as a control). Specimens were immersed for 24 h in an incubator at 37 ℃, then ultrasonically cleaned in distilled water and air-dried. Half of the specimens were tested for Vickers microhardness (VHN) at parameters of 500 gf for 10 s, while the rest of the specimens underwent 3-point flexure till fracture. Fractured surfaces were examined under a scanning electron microscope (SEM) for fracture toughness (KIC) calculation using the quantitative fractographic analysis method. Data collected were statistically analyzed using two-way analysis of variance (α = 0.05) after verification of data normality and homogeneity of variances. Results Erosive media created surface flaws that lowered the surface microhardness of the material and initiated the fracture pattern under different loads according to material type. The material type was a more predominant factor than erosive media that affected either the microhardness or the fracture toughness of CAD-CAM dental materials. The highest VHN and KIC values were found among Ceramill Zolid HT+ groups followed by IPS e.max CAD and Grandio Blocs regardless of the erosive media employed. Erosive media significantly reduced the VHN and KIC in Vita Enamic specimens compared to the rest of the material types. Conclusion All CAD-CAM materials used, except Vita Enamic, showed high resistance against the erosive acids indicating higher longevity of the material in patients frequently exposed to either extrinsic or intrinsic acid.
Collapse
Affiliation(s)
- Alaaeldin Elraggal
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Champollion street, Alexandria, Egypt.
| | - Rania Afifi
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Champollion street, Alexandria, Egypt
| | - Islam Abdelraheem
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Champollion street, Alexandria, Egypt
| |
Collapse
|
10
|
Alencar CDM, Ribeiro MES, Zaniboni JF, Leandrin TP, Silva AM, Campos EAD. Anti-erosive profile of an experimental 5% SnCl₂ varnish containing different concentrations of NaF. Braz Dent J 2022; 33:68-76. [DOI: 10.1590/0103-6440202203969] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Accepted: 03/10/2021] [Indexed: 11/21/2022] Open
Abstract
Abstract This in vitro study evaluated the anti-erosive effect of an experimental varnish containing 5% stannous chloride (SnCl₂) associated with different concentrations of NaF (NaF-free, 2.5% NaF, or 5.2% NaF) on bovine enamel and root dentin. One hundred samples were pre-eroded (0.3% citric acid, pH 2.6, 10 min) and randomized into five groups (n=10 for each substrate): Negative control - milli-Q water; NaF-free - Experimental varnish SnCl₂-free and NaF-free; 2.5 NaF - Experimental varnish 5% SnCl₂ associated with 2.5% NaF; 5.2 NaF: Experimental varnish 5% SnCl₂ associated with 5.2% NaF and positive control - Commercial varnish containing 5% NaF (Duraphat). After the varnishes were applied, the erosive and abrasive challenges were carried out for five days. Loss of tooth structure (TSL) was determined by optical profilometry, and the loss of calcium (ΔCa2+) using atomic absorption spectroscopy. Dentin analysis was also performed by SEM. A one-way ANOVA/Bonferroni test was performed to analyze the data (α=0.05). The experimental 2.5 NaF and 5.2 NaF groups showed greater effectiveness in preventing TSL when compared to the other groups (p <0.05), regardless of the substrate. In addition, these groups showed lower loss in Ca2+ content when compared to the other groups (p <0.05), for enamel and dentin. Dentin showed greater TSL and ΔCa2+ loss when compared to enamel in all treatments (p <0.05). The 5.2% and 2.5% NaF-containing experimental varnishes showed promising results in both, the prevention of TSL and the loss of Ca2+, regardless of the substrate studied.
Collapse
|
11
|
Zanatta RF, Ávila DMDS, Maia MM, Viana ÍEL, Scaramucci T, Torres CRG, Borges AB. Protection of calcium silicate/sodium phosphate/fluoride toothpaste with serum on enamel and dentin erosive wear. J Appl Oral Sci 2021; 29:e20210081. [PMID: 34614120 PMCID: PMC8523098 DOI: 10.1590/1678-7757-2021-0081] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Accepted: 06/29/2021] [Indexed: 11/24/2022] Open
Abstract
Objective To evaluate the effect of a toothpaste containing calcium silicate/sodium phosphate/fluoride associated or not to the boost serum (BS) against erosive tooth wear (ETW) on enamel and dentin. Methodology Bovine enamel and dentin specimens were subjected to an erosion-abrasion cycling model (1% citric acid - pH 3.6 -2 min / artificial saliva – 60 min, 4×/day, 5 days). Toothbrushing was performed for 15 s (2 min exposed to slurry), 2×/day, with the toothpastes (n=10): control without fluoride (Weleda), Arg/Ca/MFP (Colgate Pro-Relief), Si/PO4/MFP (Regenerate-Unilever), and Si/PO4/MFP/BS (Si/PO4/MFP with dual BS – Advanced Enamel Serum-Unilever). The effect of treatments on the eroded tissues was assessed by surface microhardness in the first day, and surface loss (SL) resulting from ETW was evaluated by profilometry (μm) after three and five days. Additional dentin specimens (n=5/group) were subjected to 20,000 brushing cycles to verify the abrasivity of the toothpastes. Data were subjected to ANOVA and correlation tests (5%). Results For enamel, no difference in microhardness was observed among the treated groups, and similar SL was obtained after 5 days. For dentin, Si/PO4/MFP/BS resulted in higher microhardness values, but none of the groups presented significantly lower SL than the control. There was no significant correlation between SL and abrasiveness. Conclusion The calcium silicate/sodium phosphate toothpaste and serum increased microhardness of eroded dentin, but they did not significantly reduce enamel and dentin loss compared to the non-fluoride control toothpaste. The abrasiveness of the toothpastes could not predict their effect on ETW.
Collapse
Affiliation(s)
- Rayssa Ferreira Zanatta
- Universidade de Taubaté - UNITAU, Departamento de Odontologia Restauradora, Taubaté, São Paulo, Brasil
| | - Daniele Mara da Silva Ávila
- Universidade Estadual Paulista - UNESP, Instituto de Ciência e Tecnologia de São José dos Campos, Departamento de Odontologia Restauradora, São Paulo, Brasil
| | - Morgana Menezes Maia
- Universidade Estadual Paulista - UNESP, Instituto de Ciência e Tecnologia de São José dos Campos, Departamento de Odontologia Restauradora, São Paulo, Brasil
| | - Ítallo Emídio Lira Viana
- Universidade de São Paulo, Faculdade de Odontologia - FOUSP, Departamento de Odontologia Restauradora, São Paulo, Brasil
| | - Tais Scaramucci
- Universidade de São Paulo, Faculdade de Odontologia - FOUSP, Departamento de Odontologia Restauradora, São Paulo, Brasil
| | - Carlos Rocha Gomes Torres
- Universidade Estadual Paulista - UNESP, Instituto de Ciência e Tecnologia de São José dos Campos, Departamento de Odontologia Restauradora, São Paulo, Brasil
| | - Alessandra Bühler Borges
- Universidade Estadual Paulista - UNESP, Instituto de Ciência e Tecnologia de São José dos Campos, Departamento de Odontologia Restauradora, São Paulo, Brasil
| |
Collapse
|
12
|
Lopes RM, Scaramucci T, Walker CL, Feitosa SA, Aranha ACC. In situ evaluation of desensitizing toothpastes for protecting against erosive tooth wear and its characterization. Clin Oral Investig 2021; 25:6857-6870. [PMID: 33977386 DOI: 10.1007/s00784-021-03975-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 05/03/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This five-phase, single-blind, crossover in situ trial evaluated the effects of desensitizing or anti-erosive toothpastes on dentin erosive wear and tubule occlusion. MATERIALS AND METHODS Some characteristics such as relative dentin abrasivity (RDA), viscosity (V), cytotoxicity, and fluoride and calcium (Ca) availability of the toothpastes were also tested. Samples were positioned on removable intraoral appliances from 15 volunteers (n=4), according to the groups, C-control (0 ppm fluoride), F-sodium monofluorophosphate (MFP), A-MFP and arginine+calcium carbonate, CSP-calcium sodium phosphosilicate, and CS-MFP and calcium silicate+sodium phosphate. Erosion-abrasion cycling was performed (1% citric acid, 2min, 6×/day; toothbrushing, 5s, 2×/day). Surface loss (SL) was evaluated by optical profilometry. Environmental scanning electron microscopy images (ESEM) counted the number of open dentin tubules (ODTs). Data were statistically analyzed (α=0.05). RESULTS There were no significant differences in SL among groups (p=0.468). The ODT for CSP, CS, and A groups were significantly lower than the control. CSP and CS presented significantly less ODT than F, but they did not significantly differ from A. F and CS were more abrasive than all the other toothpastes; CSP was more abrasive than A, and C was the least abrasive. CSP presented higher V (p<0.05). All toothpastes presented lower cell viability than the control without toothpaste exposure. F and A presented significantly higher values of F- (p<0.05). All fluoride toothpastes had similar amount of Ca, differing from the control (p<0.05). CONCLUSION Although the toothpastes caused similar degree of erosive wear, CSP and CS were able to occlude the dentin tubules. CLINICAL RELEVANCE Desensitizing toothpastes containing calcium, sodium, phosphate, and silicate could be a suitable option for treating dentin hypersensitivity.
Collapse
Affiliation(s)
- Raquel Marianna Lopes
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes, 2227 Cidade Universitária, São Paulo, SP, 05508-000, Brazil
| | - T Scaramucci
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes, 2227 Cidade Universitária, São Paulo, SP, 05508-000, Brazil
| | - Clandler L Walker
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, 1121 Michigan Street, Indianapolis, IN, 46202-5186, USA
| | - S A Feitosa
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, 1121 Michigan Street, Indianapolis, IN, 46202-5186, USA
| | - Ana Cecilia Correa Aranha
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes, 2227 Cidade Universitária, São Paulo, SP, 05508-000, Brazil. .,School of Dentistry, Special Laboratory of Lasers in Dentistry (LELO), University of São Paulo, Avenida Professor Lineu Prestes, 2226 - Cidade Universitária, Butantã, São Paulo, Brazil.
| |
Collapse
|
13
|
Siqueira VDS, Castillo AES, Mateo-Castillo JF, Pinto LDC, Garib D, Pinheiro CR. Dental hypersensitivity in individuals with cleft lip and palate: Origin and therapies. J Dent Res Dent Clin Dent Prospects 2021; 15:42-46. [PMID: 33927840 PMCID: PMC8058161 DOI: 10.34172/joddd.2021.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 12/22/2020] [Indexed: 12/03/2022] Open
Abstract
Background. Dental hypersensitivity is due to the exposure of the dentin layer after wear of enamel or cementum, exposing the dentinal tubules and the nerve endings of odontoblasts within these tubules. The present study aimed to assess the factors related to dental hypersensitivity in individuals with cleft lip and palate and the most common therapy received. Methods. The medical records of 536 patients with cleft lip and/or palate (281 males, 255 females) with a mean age of 18 were analyzed in a single center. The inclusion criterion was patients reporting dental hypersensitivity from May 2015 to October 2019. The origin of dental hypersensitivity was evaluated considering orthodontic movement, periodontal diseases, and reversible and irreversible pulpitis. The therapy indicated by the dental professionals for dental hypersensitivity were recorded. Descriptive statistics were performed. Results. Of 61 teeth with dental hypersensitivity, 10 were attributed to orthodontic movement, 21 to periodontal problems, 27 to reversible pulpitis, and three to irreversible pulpitis. The most used therapies were the application of fluoride varnish and prophylaxis, dentifrice indication for dental sensitivity, free gingival grafts, pulpectomy, desensitizing agent application, conservative endodontic treatment (direct pulp protection), and restoration of non-carious cervical lesions. Conclusion. Reversible pulpitis was the most prevalent etiologic factor of dental hypersensitivity in individuals with cleft lip and palate. Dentifrices for dental sensitivity and fluoride varnish application were frequently recommended.
Collapse
Affiliation(s)
- Viviane Da Silva Siqueira
- Dentistry Department, Hospital for Rehabilitation of Craniofacial Anomalies, Universidade de São Paulo (HRAC/USP), Bauru, São Paulo, Brazil
| | | | - Jose Francisco Mateo-Castillo
- Dentistry Department, Hospital for Rehabilitation of Craniofacial Anomalies, Universidade de São Paulo (HRAC/USP), Bauru, São Paulo, Brazil
| | - Lidiane De Castro Pinto
- Dentistry Department, Hospital for Rehabilitation of Craniofacial Anomalies, Universidade de São Paulo (HRAC/USP), Bauru, São Paulo, Brazil
| | - Daniela Garib
- Dentistry Department, Hospital for Rehabilitation of Craniofacial Anomalies, Universidade de São Paulo (HRAC/USP), Bauru, São Paulo, Brazil
| | | |
Collapse
|
14
|
Viana ÍEL, Weiss GS, Sakae LO, Niemeyer SH, Borges AB, Scaramucci T. Activated charcoal toothpastes do not increase erosive tooth wear. J Dent 2021; 109:103677. [PMID: 33895239 DOI: 10.1016/j.jdent.2021.103677] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 04/01/2021] [Accepted: 04/19/2021] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVES To assess the effect of activated charcoal toothpastes on enamel and dentin erosive wear. METHODS Ninety enamel and dentin slabs were randomly distributed into 9 experimental groups (n = 10/substrate): Artificial saliva (negative control); Elmex Caries (EXC - 1400 ppm F- as AmF, reference toothpaste without charcoal); Colgate Luminous White Activated Charcoal (CLW - 1000 ppm F- as MFP); Colgate Natural Extracts (CNE - 1450 ppm F- as NaF); Oral-B 3D White Mineral Clean (OMC - 1100 ppm F- as NaF); Curaprox Black is White (CBW - 950 ppm F- as MFP); Bianco Carbon (BIC - no F-); Natural Suavetex (NSX - no F-); Oralgen Nupearl Advanced (ONA - no F-). Specimens were submitted to a 5-day erosion-toothbrushing abrasion cycling. Surface loss (SL) was determined with an optical profilometer. pH and concentration of available fluoride in the slurries were also assessed. Data were statistically analyzed (α = 0.05). RESULTS For both substrates, CBW, CNE and EXC had significantly lower SL values than the control. CLW and OMC promoted significantly less dentin wear than the control. All the other groups did not differ significantly from the control. There was a strong negative correlation between SL and concentration of fluoride in the slurries for enamel (r = -0.77) and dentin (r = -0.91), and a strong positive correlation (r = 0.77) between enamel SL and pH. CONCLUSIONS For both substrates, none of the activated charcoal-based toothpastes resulted in higher SL than brushing with artificial saliva. Only two of the charcoal toothpastes and the reference toothpaste were able to provide further protection against SL. CLINICAL SIGNIFICANCE Activated charcoal-containing toothpastes are becoming popular, despite the absence of evidence supporting their safety for use by individuals with erosive tooth wear. These products did not pose an additional risk for these subjects. However, it would be preferable to use products that exhibits further protective effect.
Collapse
Affiliation(s)
- Ítallo Emídio Lira Viana
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, 2227 Professor Lineu Prestes Avenue, 05508-000, São Paulo, SP, Brazil.
| | - Guilherme Stangler Weiss
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, 2227 Professor Lineu Prestes Avenue, 05508-000, São Paulo, SP, Brazil.
| | - Letícia Oba Sakae
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, 2227 Professor Lineu Prestes Avenue, 05508-000, São Paulo, SP, Brazil.
| | - Samira Helena Niemeyer
- Department of Restorative, Preventive and Pediatric Dentistry, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland.
| | - Alessandra Bühler Borges
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, 777 Engenheiro Francisco José Longo Avenue, 12245-000, São José dos Campos, SP, Brazil.
| | - Taís Scaramucci
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, 2227 Professor Lineu Prestes Avenue, 05508-000, São Paulo, SP, Brazil.
| |
Collapse
|